compact pm release i upgrade - liftmaterial.com
TRANSCRIPT
COMPACT PM RELEASE I UPGRADE
www.fermator.com
NEW INSTALLATION
RESIDENTIALLIFTS
Automatic horizontal sliding car door
PRINTABLE VERSION: 02-03-2020ENG
DOC-FECMCBPN0C00EN-3.1
Automatic horizontal sliding car door
www.fermator.com 2COMPACT PM RELEASE I UPGRADE
Door configuration
STANDARDS
Opening EN 81-1/2Safety rules
EN 81-20/50 Safety rules
EN 81-21Existing buildings
EN 81-41Impaired mobility
EN 81-71Vandal resistance lifts EN 81-72
Firefighters liftsCat. I Cat. II
C2 - T2
PANELS
Opening
Steel panels Glass panels
Sheet metal (2)
Double skin Vision Fritted
visionWien type
visionBevel big
visionFlush big
visionFull glass in skirting
Full glass in
mooringsAluminium
glass
WC2 - T2
(2) Solid execution option.
PROTECTION
Opening
IP20Protection against a solid foreign body of
12,5 mm or morein diameter.
IPX3Protected against
sprays of water up to 60 degrees from the vertical.
IP54Protection against dust and protected against water
splashed from all directions.
IP65Sealed against dust and protected against jets of water from all directions.
EExExplosion proof, Group II (surface industries) and Category 2 (explosive
atmosphere between 10 and 1.000 hrs/yr).
Magnetic contact Mechanical contactC2 - T2
APPLICATION RANGE
Opening Clear opening - PL (mm) Clear height - HL (mm)
C2 - T2 700 - 1.000 2.000 - 2.100
LIFT APPLICATION Door cycles per year: Up to 350.000.Traffic peak of the door: Up to 240 cycles per hour.
Traffic lift speed: Up to 2 m/s.
Available1. Ask the commercial department.Not available.1Some option combinations may not be possible.
SILLS
Type of sill Aluminium Reinforced aluminium Steel Steel concealed Massive
Profile detail
Availability
Heated sill option
Dust holes
Sill support
www.fermator.com3 COMPACT PM RELEASE I UPGRADE
Door configuration
COMPATIBILITY
Toe guard type BigH(3) 750
Thickness 1,5Range All
(3)Retracted toe guard dimension between brackets.T2 opening shown.
If not otherwise indicated all dimensions in mm.
160
6090
250
110
20
90 30 90±0
H
AFO
HL
HL + 295
Case Compact landing doorCoupling Symmetrical clutch
Unlocking zone +133 / -116
Available1. Ask the commercial department.Not available.1Some option combinations may not be possible.
SAFETY DEVICES
Opening Photocell Photoelectric barrier Safety edgeEmergency power
supplyStatic Dynamic VF5+ VF7
C2 - T2
PANEL REGULATION SUPPORT AND PANEL GUIDE
Type of panel regulation support Direct fastening
Type of panel guide
Basic
Sill track 8 mm
Plus
Sill track 8 mm
www.fermator.com 4COMPACT PM RELEASE I UPGRADE
DRIVEType Synchronous brushless permanent magnets motor.
Efficiency 80%.Consumptions Standby 4 W / Average per cycle 20 W.Transmission Gearless. PL 700 - 1.000 mm. HTD 5M belt.
ELECTRONIC MODULEType VF5+ and VF6 VF7+ Relay and VF7+ CAN
Adjustable parameters via PC / Console. PC / Display.Working signals available From 12 V to 60 V AC/DC / 100 V to 230 V AC or with BUS CAN.
Opening speed Up to 1 m/s. Manually adjustable and auto-adjustable directly with the panel weight.Closing speed Up to 0,6 m/s. Manually adjustable and auto-adjustable directly with the panel weight.
Re-opening Integrated with auto-adjustable cycles.
GENERAL FEATURESNoise level < 50 dB.Total weight Reference: T2 PL 800 mm HL 2.000 mm, with sheet metal panels - 55 kg.
Maximum moving mass 360 kg.Locking device Car door lock.
Technical features
INSTALLATIONPre-adjusted and tested to simplify the installation.
T2 operator
www.fermator.com5 COMPACT PM RELEASE I UPGRADE
= =
160
530
=
==
=
233,515
275
233,5
60
30
5454
100
83
120 120
5
49
5415
222,5
≥ 20
≥ 20
18
222,5
≥ 20
222,5
≥ 20
222,5
≥ 20
222,5
≥ 20
222,5
≥ 20
20
2PL + 40
PL/2 + 20
HL+
20
2PL + 50
PL
HL
HL+
295
HL
+105
±15
HL
+195
±15
HL
+270
±15
HL
+220
-20
+10
±15
HL
+ 13
5
±15
HL
+ 16
5
4≤x≤6
CARFLOOR
Con
cent
ricØ
48
PL/2 PL/2
PL
Technical drawing 2 panel centre parting door
SILLDETAIL
54 mm sill
- If not otherwise indicated all dimensions in mm.
Notes:
MECHANICALDETAILS
FIXING BRACKET RANGE
thickness2
thickness2
STATICC0 BRACKET
STATICF0 BRACKET
STATICB0 BRACKET
STATICE0 BRACKET
STATICA0 BRACKET
STATICD0 BRACKET
www.fermator.com 6COMPACT PM RELEASE I UPGRADE
30
5
40 40
305
20
14572,5
90
25 100
155
275
15
25
120
6090
9083
30
100
120
20
≥ 20
PL - 134 129
PL + 124
222,5
≥ 20
222,5
≥ 20
222,5
≥ 20
222,5
≥ 20
222,5
≥ 20
222,5
≥ 20
HL+
20
HL
HL+
295
HL
+105
±15
HL
+195
±15
HL
+270
±15
HL
+220
±15
HL
+ 13
5
±15
HL
+ 16
5
PL/2 + 20
1,5PL + 50PL
1,5PL + 40
PL
4≤x≤6
4≤x≤6
PL
CARFLOOR
Con
cent
ricØ
48
Technical drawing 2 panel side opening door
90 mm sill
SILLDETAIL
- If not otherwise indicated all dimensions in mm.
Notes:
MECHANICALDETAILS
FIXING BRACKET RANGE
thickness2
thickness2
STATICC0 BRACKET
STATICF0 BRACKET
STATICB0 BRACKET
STATICE0 BRACKET
STATICA0 BRACKET
STATICD0 BRACKET
www.fermator.com7 COMPACT PM RELEASE I UPGRADE
24946 141 3527
38,5
50
2538,5
24976 111 3527
38,5
50
25
38,5
249106 81 3527
38,5
50
25
38,5
249
136 51 3527
38,5
50
25
38,5
249
166 21 3527
38,5
50
25
38,5
280
187 12 5625
38,5
50
25
38,5
12,2
5
50
100222,5
39,583
56,75
12,2
5
50
100222,5
39,583
56,75
12,2
5
50100
222,539,583
56,75
12,2
5
50
100222,5
39,583
56,7512
,25
50
100222,5
39,583
56,75
12,2
5
50
100222,5
39,583
56,75
A0
B0
C0
D0
E0
F0
A’
A’
A’
A’
A’
A’
B’
B’
B’
B’
B’
B’
A
A
A
A
A
A
B
B
B
B
B
B
A’
A’
A’
A’
A’
A’
A
A
A
A
A
A
B
B
B
B
B
B
B’
B’
B’
B’
B’
B’
Operator fixing bracket
9 www.fermator.com COMPACT PM RELEASE I UPGRADE
TYPES OF SUPPORT6
Only VF circuit VF circuit with emergency power supply for PL ≥ 800
VF circuit with emergency power supply for PL < 800
Standard execution
38717
4
40
5
6
7
13
21
23
22
51
25
24
26
N
PE
L
U
V
W
PEM
56
57
58
59
47
45
43
41
39
37
35
33
31
46
42
44
40
36
38
34
30
32 12
9
10
11
8
55
OK STATUSOK ESTADO
CERRAR LENTO
SLOW CLOSE
OUT +12 V
REABRIR
RE-OPEN
SEÑAL DE PISO
FLOOR LEVEL
ABIERTA
OPEN
CERRADA
CLOSED
OBSTRUCCIÓN
OBSTRUCTION
ABRIR
OPEN
0 V
COM
OUT +12 V
CERRAR
CLOSEEN 12016: 2013 INMUNIDAD NIVEL INDUSTRIAL
EN 12016: 2013 IMMUNITY INDUSTRIAL LEVEL
ALIM. SUPPLY
100...230 V
AC
MOTOR
ENCODER
ON
OFF
ENTRADAS PRIORITARIAS / PRIORITY INPUTS
ENTRADAS / INPUTS
SALIDAS / OUTPUTS
PUERTO COM
COM PORT
NO ABRIR LA TAPA
DO NOT OPEN THE COVER
ATENCIÓN / CAUTION
AUTOADJUSTMENT
Push to calibrate
the door
AUTOAJUSTE
Pulsar para
ajustar la puerta
QCI-VF.7P.C.I.0.EE
CONTACTO DE BYPASS
BYPASS CONTACT
FALLO
BARRERA
BARRIER
FAILURE
SOBRE
TEMPERATURA
OVER
TEMPERATURE
FALLO BARRERA
BARRIER FAILURE
REABRIR
RE-OPEN
782
176
40
5
6
7
13
21
23
22
51
25
24
26
N
PE
L
U
V
W
PEM
56
57
58
59
47
45
43
41
39
37
35
33
31
46
42
44
40
36
38
34
30
32 12
9
10
11
8
55
OK STATUSOK ESTADO
CERRAR LENTO
SLOW CLOSE
OUT +12 V
REABRIR
RE-OPEN
SEÑAL DE PISO
FLOOR LEVEL
ABIERTA
OPEN
CERRADA
CLOSED
OBSTRUCCIÓN
OBSTRUCTION
ABRIR
OPEN
0 V
COM
OUT +12 V
CERRAR
CLOSEEN 12016: 2013 INMUNIDAD NIVEL INDUSTRIAL
EN 12016: 2013 IMMUNITY INDUSTRIAL LEVEL
ALIM. SUPPLY
100...230 V
AC
MOTOR
ENCODER
ON
OFF
ENTRADAS PRIORITARIAS / PRIORITY INPUTS
ENTRADAS / INPUTS
SALIDAS / OUTPUTS
PUERTO COM
COM PORT
NO ABRIR LA TAPA
DO NOT OPEN THE COVER
ATENCIÓN / CAUTION
AUTOADJUSTMENT
Push to calibrate
the door
AUTOAJUSTE
Pulsar para
ajustar la puerta
QCI-VF.7P.C.I.0.EE
CONTACTO DE BYPASS
BYPASS CONTACT
FALLO
BARRERA
BARRIER
FAILURE
SOBRE
TEMPERATURA
OVER
TEMPERATURE
FALLO BARRERA
BARRIER FAILURE
REABRIR
RE-OPEN
546
250
40
5
6
7
13
21
23
22
51
25
24
26
N
PE
L
U
V
W
PEM
56
57
58
59
47
45
43
41
39
37
35
33
31
46
42
44
40
36
38
34
30
32 12
9
10
11
8
55
OK STATUSOK ESTADO
CERRAR LENTO
SLOW CLOSE
OUT +12 V
REABRIR
RE-OPEN
SEÑAL DE PISO
FLOOR LEVEL
ABIERTA
OPEN
CERRADA
CLOSED
OBSTRUCCIÓN
OBSTRUCTION
ABRIR
OPEN
0 V
COM
OUT +12 V
CERRAR
CLOSE EN 12016: 2013 INMUNIDAD NIVEL INDUSTRIAL
EN 12016: 2013 IMMUNITY INDUSTRIAL LEVEL
ALIM. SUPPLY
100...230 V
AC
MOTOR
ENCODER
ON
OFF
ENTRADAS PRIORITARIAS / PRIORITY INPUTS
ENTRADAS / INPUTS
SALIDAS / OUTPUTS
PUERTO COM
COM PORT
NO ABRIR LA TAPA
DO NOT OPEN THE COVER
ATENCIÓN / CAUTION
AUTOADJUSTMENT
Push to calibrate
the door
AUTOAJUSTE
Pulsar para
ajustar la puerta
QCI-VF.7P.C.I.0.EE
CONTACTO DE BYPASS
BYPASS CONTACT
FALLO
BARRERA
BARRIER
FAILURE
SOBRE
TEMPERATURA
OVER
TEMPERATURE
FALLO BARRERA
BARRIER FAILURE
REABRIR
RE-OPEN
6 The external support ensures the easy access to the VF circuit controls within the PL.
ASSEMBLY OPTIONS
Faced to the landing. Faced to the car roof.
The type of support shown it is only a example, the assembly options are available for any type of support.
NC
NC
Electronic module support
Fermator reserves the right to make changes to the specification of the products within this catalogue without prior notice.
General: [email protected]: [email protected] • Brazil: [email protected] • Italy: [email protected] • France: [email protected], [email protected]
China: [email protected] • India: [email protected] • Poland: [email protected] • Germany: [email protected] Middle East: [email protected] • Nordic countries: [email protected]
Sales contacts