Condition Criticality Risk Rating and Condition Monitoring in a Distribution Network. PAUL DYER DAVE OPENSHAW London Electricity Group. What am I going to talk about ? Risk Management Maintenance strategies Plant specific diagnostics What are the benefits Summary. - PowerPoint PPT PresentationTRANSCRIPT
Paul Dyer
Condition Criticality Risk Rating and Condition
Monitoring in a Distribution Network
PAUL DYERPAUL DYERDAVE OPENSHAWDAVE OPENSHAW
London Electricity GroupLondon Electricity Group
Paul Dyer
What am I going to talk aboutWhat am I going to talk about ??
Risk ManagementRisk ManagementMaintenance strategiesMaintenance strategies
Plant specific diagnosticsPlant specific diagnosticsWhat are the benefitsWhat are the benefits
SummarySummary
Paul Dyer
Ensure safety of staff and members of the public
Prevent interruption to supply Extend the useful life of the asset Ensure that the most cost effective
solutions in place Enable informed asset replacement
policy
Paul Dyer
Asset Condition Importance is:
f: Asset Population
f: Probability of Failure
f: Impact of Failure on Business
Population = 35,000
Population = 1,100
The probability and failure impact when considering (say)quality of supply effects may be very different to that whenconsidering (say) environmental effects
For any generic group of assets, asset condition importancecan be expressed as a function of three things:
Paul Dyer
m = Maintenance or Replacement Window
f = Critical Failure (or Uncertainty) Period
m + f = ‘P-F’ Interval
Asset Condition
Time or Duty
Functional Failure
As New
Potential Failure (Fails ConditionAcceptance Criteria)
Unacceptable Risk of Failure
m f
Risk-AverseMaintenance /Replacement Strategy
Hi-Risk (Reactive) Maintenance/ Replacement Strategy
Optimum Maintenance /Replacement Strategy
Paul Dyer
0
2
4
6
8
10
12
14
16
18
20
0 10 20 30 40 50 60 70 80 90
Infant Mortality
How long ?
How long ?
BATHTUB CURVE
FAIL
UR
E R
ATE
Paul Dyer
Reactive Reactive
FORFOR Considered to be Considered to be
cheapcheap No policy to developNo policy to develop No routine No routine
maintenance to maintenance to budget forbudget for
AGAINSTAGAINST Safety riskSafety risk Unscheduled down Unscheduled down
timetime Damage to plantDamage to plant Teams always to be Teams always to be
readyready Loss of confidenceLoss of confidence
Paul Dyer
FORFOR Easy to predict Easy to predict
labour and planlabour and plan Can ensure Can ensure
maintained before maintained before failurefailure
AGAINSTAGAINST Not easy to predict Not easy to predict
failurefailure Easy to over or Easy to over or
under maintainunder maintain
Time basedTime based
Paul Dyer
Duty basedDuty based
FORFOR Tailored to actual Tailored to actual
usageusage Minimises workMinimises work
AGAINSTAGAINST Needs development Needs development
work to set duty work to set duty levelslevels
Requires hours run Requires hours run or other duty or other duty counterscounters
Paul Dyer
Condition basedCondition based
FORFOR Tailored to plant Tailored to plant
conditioncondition Minimises work and Minimises work and
knowledge of plant knowledge of plant conditioncondition
AGAINSTAGAINST Needs development Needs development
work to set condition work to set condition levels levels
Requires diagnostic Requires diagnostic equipmentequipment
Requires some skill Requires some skill to assess conditionto assess condition
Paul Dyer
Transformer diagnosticsTransformer diagnostics
Moisture and dielectric testsMoisture and dielectric tests Dissolved gas in oil analysisDissolved gas in oil analysis Furfuraldehyde analysisFurfuraldehyde analysis Hydran on/off lineHydran on/off line Metal in oilMetal in oil Particle analysisParticle analysis
Paul Dyer
Maintenance strategiesMaintenance strategiesSwitchgearSwitchgear
So what diagnostics do we have available?So what diagnostics do we have available?1. Discharge1. Discharge
Transient Earth Voltage monitoringTransient Earth Voltage monitoring Ultrasonic detectionUltrasonic detection Radio frequency detectionRadio frequency detection Discharge sensitive gelDischarge sensitive gel
Paul Dyer
Paul Dyer
Maintenance strategiesMaintenance strategiesCable diagnosticsCable diagnostics
Why are we interested in cables?Why are we interested in cables?
Main cause of loss of supplyMain cause of loss of supply Failure is commonFailure is common Adversely affects KPIsAdversely affects KPIs Main nuisance to customersMain nuisance to customers
Paul Dyer
Maintenance strategiesMaintenance strategiesCable diagnosticsCable diagnostics
So what can we do?So what can we do?
Monitor failures Monitor failures Off line partial discharge testsOff line partial discharge tests On line partial discharge monitoringOn line partial discharge monitoring
Paul Dyer
SUMMARYSUMMARY
What measurements are important?What measurements are important? Evaluate the risk to the systemEvaluate the risk to the system
What data tells me most about equipment What data tells me most about equipment operating condition?operating condition?
Do I need to take measurements from each itemDo I need to take measurements from each item How much will it cost ?How much will it cost ?
How much time interpreting the results?How much time interpreting the results? Will the measurements be acted upon?Will the measurements be acted upon?
Paul Dyer