consumer access dimensions - diebold nixdorf · consult with diebold nixdorf installation/service...
TRANSCRIPT
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 1 O
F 5
L1251
CALL 1-800-999-3600FIL
E N
O. 177-6
97 R
EV. 0
PLAN VIEW
FRONT ELEVATIONSIDE ELEVATION
G
H
J
K
B
C
A
E
D
F
L
I
670
")83(26
1158
")16
9(4
5
643
")165(25
1637
")16
7(6
4
670
")83(26
643
")165(25
1158
")85(45
197
")83(14
366
")43(7
1637
")16
7(6
4
573
")16
9(2
2
1605
")16
3(6
3
")8
1(3
80
")8
7(1
48
1024
")165(40
768
")41(30
AIR VENTS
SAFE
DEPTH DIMENSIONS
EDGE OF BEZEL FOR
REFERENCE FRONT
SAFE
SAFE
O
19" DISPLAY
N
15" DISPLAY SHOWN
15" DISPLAY SHOWN
HEIGHT - FROM BOTTOM OF SAFE
DEPTH - FROM FRONT EDGE OF BEZEL
TERMINAL WITH 15” AND 19” DISPLAYSSHARE ALL THE SAME DIMENSIONS EXCEPT
DISPLAY SIZE AND FUNCTION KEYS ARE NOT
AVAILABLE ON THE 19” DISPLAY
THE FRONT EDGE OF BEZEL
THAT EXTEND OUT TOWARD THE CUSTOMER FROM
DEPTH DIMENSIONS MARKED SHOW COMPONENTS *
M
HEIGHT DEPTH
A
B
E
C
D
")81(52
1324mm
CONSUMER ACCESS DIMENSIONS
")1613(6
172mm
")167(5
138mm
")1611(43
1109mm
")85(36
930mm
F
RECEIPT PRINTER
G
H
I
J
K
L
")169(31
802mm
")81(44
1121mmHEADPHONE JACK
")85(36
931mm
")169(36
928mm
")1611(31
805mm
")43(31
807mm
BOTTOM OF CONSUMER DISPLAY
TOP OF CONSUMER DISPLAY
TOP FUNCTION KEY
COIN DISPENSER (OPTIONAL)
CONTACTLESS CARD READER (OPTIONAL)
ActivCheck
EMV-READY CARD READER
ActivRecycle
EPP KEY
FINGERPRINT READER (OPTIONAL)
")21(5
139mm
")161(
2mm
")169(8
217mm
")43(7
197mm
")43(7
197mm
")43(7
197mm
")43(7
197mm
")167(5
138mm
(39")
991mm
")1615(31
810mm
M
N ")43(54
1390mm
")169(43
1106mm
TOP OF 19" CONSUMER DISPLAY
BOTTOM OF 19" CONSUMER DISPLAY
")83(9
239mm
")83(5
136mm
(48")
1219mm
O
2D BAR CODE SCANNER (OPTIONAL)")16
7(- 2
- 61mm **
*
")161(-1
-27mm
")43(-
-18mm
")85(29
752mm
" T
O 3")
16
7L
EV
ELIN
G R
AN
GE 1
1m
m T
O 7
6m
m (
SA
FE
SEE PLANNING AND SITE PREPARATION GUIDE TP-821975-001.
BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE
CONSULT WITH DIEBOLD NIXDORF INSTALLATION/SERVICE
") UL SAFE21WITH 13mm (
15" DISPLAY OR 19" DISPLAY
CS 3700 LOBBY CASH RECYCLER- FRONT LOAD
LOW ABSOLUTE HUMIDITY 1g WATER / Kg DRY AIR
HIGH ABSOLUTE HUMIDITY 32g WATER / Kg DRY AIR (MAXIMUM WET BULB 35°C)
MAX RATE OF CHANGE 10% PER HOUR
RELATIVE HUMIDITY (NON-CONDENSING) (INSIDE) 20% TO 80%
MAX RATE OF CHANGE 10°C (18°F) PER HOUR
0°C TO 38°C (0°F TO 100°F)
TEMPERATURE (INSIDE AT OUTSIDE WALLS OF UPPER CABINET AND SAFE)
PR
OJE
CTIO
N
THIR
D A
NG
LE
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 2 O
F 5
EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.
NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH
BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR
4
NOTE:
200-240 VAC (±10%) SERVICE, DISCONNECT AT 10 AMPERES
100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES
SIGNAL CABLE RUN CONSTRAINTS
ELECTRICAL EQUIPMENT CABLE RUN.
OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS
AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION.
POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION
RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE
SIGNAL CABLE INSTALLATION CONSTRAINTS:
WEIGHT OF UNIT:
POWER USAGE:
HEAT OUTPUT CONFIGURATION:
POWER REQUIREMENTS:CONDUIT AND JUNCTION BOX REQUIREMENTS
PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA.
CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE
JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF
SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.
POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO
THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
(SEE POWER REQUIREMENTS).
MUST BE COMPENSATED ACCORDINGLY (ALL BY OWNER'S E.C.)
WITHIN 2210mm (87") OF SIDE CONNECTING PLATE. BOTTOM CONNECTION
") DEEP JUNCTION BOX WITH RECEPTACLE81102mm (4") SQ. X 54mm (2
") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 4319mm (
LENGTH 2210mm (87") FROM SIDE OF UNIT.
SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD
OWNER'S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY
1
2
3
(OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE
SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT
POWER TO THE TERMINAL IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A
POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW.
IS NOT ACCEPTABLE). THE TERMINAL WILL PROVIDE A POWER CORD WITH A COUNTRY SPECIFIC
WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND
THE TERMINAL REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE.
CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE:
200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE
200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE
100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE
100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE
TYPE OF ELECTRICAL RUN
LIGHTING FIXTURES
FLUORESCENT, NEON OR INCANDESCENT
ELECTRICAL EQUIPMENT
UNSHIELDED POWER LINE OR
CONDUIT
WITH SIGNAL CABLES IN GROUNDED
POWER LINES IN GROUNDED CONDUIT
BELOW 2 KVA 2-5 KVA ABOVE 5 KVA
127mm (5") 127mm (5") 127mm (5")
127mm (5") 305mm (1'-0") 610mm (2'-0")
")2164mm (2 152mm (6") 305mm (1'-0")
")16330mm (1 76mm (3") 152mm (6")
GROUNDED CONDUIT
SIGNAL CABLES ENCLOSED IN
ELECTRICAL EQUIPMENT WITH
UNSHIELDED POWER LINES OR
SEPARATION FROM OTHER CABLES
OPERATING ENVIRONMENT:
BACK ELEVATION
SIDE ELEVATION
201
")167(14
366
")87(7
")8
1(3
79
")8
7(1
48
768
")41(30
1158
")169(45
643
")165(25
670
")83(26
154
")87(5
150
")167(14
366
")161(6
")8
1(3
80
")8
7(1
48
1604 ")8
1(6
3
AIR VENTS
366
")21(1
38")167(14
1024
")165(40
SAFE
OF UNIT
2210mm (87") FROM SIDE
POWER CORD - LENGTH
573
")8
1(3
80
")8
5(1
42
")16
9(2
2
1
3
1
4
2
3 1637
")16
7(6
4
AIR VENTS
AIR VENTS
")RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTION PLATE.4319mm (
") LIQUID TIGHT FLEX METAL CONDUIT OR 43OWNER'S E.C. TO RUN 19mm (
IDLE (NO TRANSACTION)
IN PROGRESS)
TRANSACTION (DISPENSE
CONFIGURATION
A
A
CHARGING
WITH BATTERY
A
382 WATTS
STD LCD DISPLAY
NO HEATER
MACHINE STATUS
125 WATTS
374 WATTS
133 WATTS
ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED.
RECYCLER AND THE TYPE OF TRANSACTION THE RECYCLER IS PERFORMING. VALUES
THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE
JOURNAL PRINTER, IDM BD, COIN DISPENSER AND ECRM LITE
REAR TOUCH SCREENS, SECURE CARD READER, RECEIPT PRINTER (SNOWHAVEN),
PROCESSOR (HPSTD), CCR2, EPP7 AND FUNCTION KEY, REAR DISPLAY, FRONT AND
454 BTU/HR DISPENSING
427 BTU/HR IDLEA
1276 BTU/HR IDLE
1303 BTU/HR DISPENSINGA
CHARGING
WITH BATTERY
SAFE
SWITCH IS PROVIDED BY THE DNA SERVICE ORGANIZATION.
BOX. (ALL BY OWNER'S E.C.) DNA ONLY-FLAT COVER WITH TAMPER
") DEEP JUNCTI0N 81JUNCTION BOX TO 102mm (4") SQ. X 54mm (2
25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET
CONFIGURATION OF THE TERMINAL COMPONENTS AND OPTIONS
ACTUAL WEIGHT OF THE TERMINAL WILL DEPEND ON THE
757 kg (1,169 LBS.)
" T
O 3")
16
7L
EV
ELIN
G R
AN
GE 1
1m
m T
O 7
6m
m (
1605
")16
3(6
3
573
")16
9(2
2
SA
FE
FIL
E N
O. 177-6
97 R
EV. 0
PR
OJE
CTIO
N
THIR
D A
NG
LE
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 3 O
F 5
FIL
E N
O. 177-6
97 R
EV. 0
RECOMMENDED SERVICE AREA
MUST ENTER UNIT IN THIS AREA
ALL ELECTRICAL AND DATA CABLES
SIDE ELEVATION
MINIMUM SERVICE AREA
RECOMMENDED SERVICE AREA
PLAN VIEW
MINIMUM SERVICE AREA
PLAN VIEW
2443
")163(96
1789
")16
7(7
0
NOTE:
342
(12")
305
")1613(
20
")165(25
643
(6")
152
")167(13
1462
")169(57
")16
13
(491265
")16
9(4
51158
")16
13
(
20
767
")16
3(3
0
2443
")16
3(9
6
1158
")16
13
(491265
")8
5(4
5
309
(6")
152
")16
3(1
2 (2")
50
910
")16
13
(35
2443
")16
3(9
6
")16
13
(491265
")8
5(4
5
1158
")16
13
(
20 315
(12")
305
")1613(
20
")165(25
643
")1613(12
325
")83(12
1608
")165(63
309
(6")
152
")16
3(1
2 (2")
50
1158
")16
13
(491265
")16
9(4
5
910
")16
13
(35
SAFE SAFE
TE
RMIN
AL
TE
RMIN
AL
FRONT LOAD - SERVICE AREAS
CS 3700 LOBBY CASH RECYCLER
FOR SERVICE AREA OF ADJACENT UNITS SEE PAGE 4 OF 5
DIEBOLD NIXDORF INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS.
MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE TIME. CONSULT WITH
INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE MINIMUM AREA
SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE
SHOWN ARE THE MINIMUM AND RECOMMENDED AREA REQUIRED FOR INSTALLATION AND
PR
OJE
CTIO
N
THIR
D A
NG
LE
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 4 O
F 5
PLAN VIEW - ADJACENT UNITS (MINIMUM SERVICE AREA)
MINIMUM SERVICE AREA
IN THIS AREA
CABLES MUST ENTER UNIT
ALL ELECTRICAL AND DATA
3453
")1615(135
")16
13
(491265
")16
9(4
51158
")16
13
(
20
767
")16
3(3
0
2443
")16
3(9
6
309
(6")
152
")16
3(1
2 (2")
50
SAFE
1158
")16
13
(491266
")16
9(4
5
910
")16
13
(35
342
")1613(
20
")165(25
643
")87(13
352
")165(25
643
")87(13
352
")165(25
643
(6")
152
")167(13
480
")41(12
312
")83(26
670
")1613(12
325
")83(26
670
")1613(12
325
")83(26
670
")1615(18
SERVICE AREA - ADJACENT UNITS
TE
RMIN
AL
(12")
305SAFE SAFE
FIL
E N
O. 177-6
97 R
EV. 0
FIL
E N
O. 177-6
97 R
EV. 0
ALARM CABLES (SIDE ENTRY)
") DIA. HOLE FOR8129mm (1
POWER CABLE PLATE
(SIDE ENTRY)
CORD AND DATA CABLES
OPENINGS FOR POWER
SAFE FLOOR MOUNTING DETAILS
CABLE ENTRY NOTE
2 (4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES
") DIA. LEVELING LEG HOLES1691 (4) 14mm (
PLAN VIEW - SAFE FLOOR
SEE NOTE
CABLE ENTRY
1
2
1
2
1
SAFE
SA
FE
1023
")16
5(4
0
")167(1
36
")21(22
571")16
7(1
36
1
2 2
NOTES:FOR ADDED SECURITY:
ANCHORING SAFE TO CONCRETE FLOORS:
ANCHORING THE CASH DISPENSER TO WOOD FLOORING:
ANCHORING THE CASH DISPENSER TO STEEL FLOORS:
").21BE AT LEAST 13mm (
PROVIDE ADDITIONAL STRENGTH. THE COMBINED BACKING PLATE AND FLOOR THICKNESS MUST
A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO
OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO
METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS
CASH DISPENSER INSTALLED ON STEEL FLOORS CAN BE SECURED BY A MACHINE-THREADED
USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR YOUR INSTALLATION.
IT IS RECOMMENDED THAT THE TERMINAL SAFE BE SECURED TO THE FLOOR WITH ANCHOR BOLTS.
HOLDING CAPACITY OF A WOOD FLOOR WILL BE LESS THAN THAT OF CONCRETE FLOORS.
") THICK. IT IS IMPORTANT TO NOTE THAT THE OVERALL 41STRENGTH. THE REINFORCEMENT PLATE IS TYPICALLY 6mm (
TO A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL
SUPPORTING POSTS OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH
BY A MACHINE-THREADED NUT AND BOLT METHOD. IT IS PREFERRED THAT THE HARDWARE BE ATTACHED THROUGH
CASH DISPENSERS INSTALLED ON WOOD FLOORS OR FLOORS SUPPORTED BY WOODEN BEAMS CAN BE SECURED
")8
3(2
6670
(6")
152
366
")2
1(1
38
")16
7(1
4
")16
9(5
142
")16
7(3
3849
")16
5(1
33
")83(3
85
(19")
483
")1615(2
75
IS NO LIMIT FOR MAXIMUM THICKNESS. ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES.
FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm (4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE
") ANCHOR BOLT THAT IS 203mm (8") LONG. CONCRETE 43DIEBOLD NIXDORF RECOMMENDS USING A M20 OR 19mm (
IT IS RECOMMENDED THAT THE TERMINAL SAFE BE ANCHORED TO CONCRETE FLOORS WHENEVER POSSIBLE.
OF THE SAFE AS VIEWED FROM THE FRONT OF THE TERMINAL.
OPENING. THE CABLE ENTRY OPENING IS ON THE LEFT SIDE
THE INTERIOR SIDE WALL OF THE SAFE AT THE CABLE ENTRY
SAFE AND THROUGH A RESTRICTOR BRACKET ATTACHED ON
CABLE PLATE ATTACHED TO THE EXTERIOR SIDE WALL OF THE
CABLES ENTERING THE TERMINAL PASS THROUGH THE POWER
THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE.
ELECTRICAL AND DATA CABLING ENTERS THE TERMINAL
(8")
203
MIN.
(4")
102
MIN.
203mm (8")
MINIMUM HOLE DEPTH
102mm (4")
MINIMUM CONCRETE DEPTH
VIEW "A" VIEW "B"
DIEBOLD NIXDORF PART NUMBER 29-016376-000A, HILTI PART NUMBER 282520).
")-10 X 203mm (8") LONG WEDGE ANCHORS (SUPPLIED BY OWNER'S INSTALLER) 4319mm (
WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4)
IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR
") DIA. X 203mm (8" MIN.) DEEP HOLES43OWNER'S INSTALLER TO DRILL (4) 19mm (
PR
OJE
CTIO
N
THIR
D A
NG
LE
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 5 O
F 5
643
")165(25