consumer products kinesiology tape / wristbands

15
CONSUMER PRODUCTS Kinesiology Tape / Wristbands Rusty Lundberg Utah Division of Radiation Control OAS Annual Meeting August 26, 2014 Utah Department of Environmental Quality

Upload: uriah-hale

Post on 03-Jan-2016

21 views

Category:

Documents


1 download

DESCRIPTION

CONSUMER PRODUCTS Kinesiology Tape / Wristbands. Rusty Lundberg Utah Division of Radiation Control OAS Annual Meeting August 26, 2014. Utah Department of Environmental Quality. EVENT. Initial embargo of Kinesiology Tape (K-tape) at the Port of Los Angeles containing Th-232 - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

CONSUMER PRODUCTS

Kinesiology Tape / Wristbands

Rusty LundbergUtah Division of Radiation Control

OAS Annual MeetingAugust 26, 2014

Utah Department of Environmental Quality

Page 2: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

EVENT

Initial embargo of Kinesiology Tape (K-tape) at the Port of Los Angeles containing Th-232

Identification of U.S. importer Endevr™ – located in St. George, Utah

Formerly DBA LifeStrength, LLC Distributor, wholesale and retail sales

(including online) Also sells silicone wrist bands using

negative ion technology Eventual inclusion of wrist bands

Page 3: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

SEQUENCE OF EVENTS

FDA Inspection of Endevr™ Endevr™ follow-up actions / contacts made Utah DRC (UDRC) notification

NRC Region 4 (email February 2014) UDRC

Contacts made with: NRC, FDA, OAS, Endevr™, CA

UDRC Site visit of Endevr™ Conference calls

FDA, NRC, OAS, CRCPD

Page 4: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

Endevr™ – St. George, Utah

Page 5: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

SITE INSPECTIONFebruary 19, 2014

Date Findings

photos

Page 6: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

SITE INSPECTION

Findings No manufacturing of products at site Exposure rate measurements taken

Warehouse – Background ~ 10 µR/hr Warehouse – surface box containing about

2,000 wrist bands ~ 60 µR/hr (net) No removable contamination detected Collected sample K-tape and wrist

bands Wrist bands analyzed by UDRC & ORAU

Sent report to NRC

Page 7: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

K-TAPE / WRIST BANDS

Page 8: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

ANALYTICAL WORK

K-tape FDA – WEAC FDA – Health Risk Assessment

Wristbands OAS

VA & CO (UT DRC) NRC – Oak Ridge

Page 9: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

ANALYTICAL RESULTS

Percent by Weight of Thorium-232Endevr™ Wrist Band Samples

Gamma Spectroscopy

Analytical Service Provider

Low High

Utah 0.020% 0.090%

     

Colorado 0.037% 0.176%

     

Virginia 0.090% 0.170%

     

NRC – ORISE 0.080% 0.200%

Page 10: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

ANALYTICAL RESULTS

Percent by Weight of Thorium-232in Negative Ion Powder*

by Inductively Coupled Plasma-Atomic Emission Spectrometry

Analytical Service Provider

Low High

CITEK** <0.001% <0.01%

*Wrist bands Endevr™ purchases use negative ion powder at a concentration of 3% of the silicone matrix.

** Shenzhen Citek Technology Co., TLD (Zhejiang Province, China)

Page 11: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

COMMUNICATIONS

NRC to OAS/UDRC

OAS/CRCPD/NRC Monthly calls

FDA to UDRC

FDA analytical results

Page 12: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

UTAH ACTIONS

New web page

Page 13: CONSUMER PRODUCTS Kinesiology Tape / Wristbands
Page 14: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

UTAH ACTIONS

Coordination with Endevr™ Final disposition of unsold wristbands

likely subject to licensing and remaining as stored inventory

Periodic evaluation of products now being sold/distributed with lower source concentration in ion powder

Page 15: CONSUMER PRODUCTS Kinesiology Tape / Wristbands

Contact Information:

Rusty LundbergUtah Division of Radiation Control

[email protected]

QUESTIONS?