Description Page
Meter Socket Catalog Number Logic
Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
Product Selection by Utility
Allegheny Power Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
Duquesne Light Company Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
First Energy (GPU, JCP&L, Penelec & Met Ed) . . . . . . . . . . . . . . . . . . . . .
6
Pennsylvania Power & Light (PP&L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
Philadelphia Electric Company (PECO) . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
Atlantic City Electric/Delmarva Utility. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
Delaware Electric Co-Op . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
Technical Data
Knockout Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
Meter Packs
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
Main Tenant Circuit Breakers
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
Dimensions and Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
Accessories
Meter Packs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
Group Metering
TD00505006E.fm Page 1 Thursday, May 10, 2007 1:13 PM
May 2007
2
For more information visit:
www.eaton.com
TD00505006E
Metering EquipmentMeter Sockets
Meter Socket Catalog Number Logic
Catalog Numbering System
Table 1. “RS” Group Catalog Numbering System
1
“RS” Group = Residential Service, Single Position.
Note:
Some sockets that are built for specific utilities have their own unique catalog numbers. These can be found on the utility selection pages.
Meter Socket “Prefix” Guide
Note:
The “U” prefix is always used first followed by other prefixes required in alphabetical order.
ABFGHI
MNRST
TTUZ
Aluminum enclosureBarrel lock provision, for an exposed INNER-TITE
T
or Brooks barrel lock; unit includes an internal lock receiver bracket.Barrel lock with guard provision, for a lock guard INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket.Grounded fifth terminal (9 o’clock position)Horn bypassInhibitor installed in wire connectorsTemporary meter cover (waxed cardboard)No sealing ring (applies only to ring style sockets)Ring style socketAluminum screw type sealing ring (applies only to ring style sockets)Grounding connector (#14 – #2 Cu) for Tri-Plex groundTwo (2) grounding connectors (#14 – #2 Cu) for Quad-Plex groundUL
T
(Underwriters Laboratories) labeled5/16" Hex head connector screw in place of slotted (100 amperes only)
Cutler-Hammer
UT RS 2 0 2 B CH
Ampere Rating
1 = 100 Amperes2 = 200 Amperes5 = 150 Amperes
Standard Suffixes
A = Solid TopB = Small Hub OpeningC = Small Hub Closure PlateL = 1-1/4" Hub
M = 1-1/2" HubN = 2" HubP = 2-1/2" HubT = Large Hub OpeningU = Large Hub Cover PlateV = 2-1/2" Large HubQ = 3" Large HubR = 3-1/2" Large HubS = 4" Large HubZ = Large to Small Hub Adapter Mounted
Maximum Conductor(Line & Load)
0 = 3/8" Stud Connectors1 = #2/0 Connectors2 = #250 kcmil Connectors3 = #350 kcmil Connectors
Service Design
0 = Overhead1 = Combination Overhead/
Underground2 = Underground, Side Wired3 = Combination, Overhead/
Underground, Side Wired
Standard Prefix(See Prefix Guide)
See Product Group
Designators 1
NOTE: “100...CH” catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system.
May 2007
TD00505006E For more information visit:
www.eaton.com
3Metering EquipmentMeter Sockets
Meter Socket Catalog Number Logic
Table 2. “2R-6R” and “2H-6H” Group Catalog Numbering System
1
“2R-6R” Group = Residential Service, Multiple Position.“2H-6H” Group = Commercial or Residential Service, Multiple Position.
Table 3. “H” Group Catalog Numbering System
2
“H” Group = Commercial or Residential Service, Single Position (lever bypass).
Note: “100...CH”
catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system.
Cutler-Hammer
UT 2R 1 1 21 B CH
Ampere Rating
1 = 100 Amperes2 = 200 Amperes
Standard Suffixes
A = Solid TopB = Small Hub OpeningC = Small Hub Closure PlateL = 1-1/4" Hub
M = 1-1/2" HubN = 2" HubP = 2-1/2" HubT = Large Hub OpeningU = Large Hub Cover PlateV = 2-1/2" Large HubQ = 3" Large HubR = 3-1/2" Large HubS = 4" Large HubZ = Large to Small Hub Adapter Mounted
Maximum Conductor(Line & Load)
0 = 3/8" Stud Connectors1 = #2/0 Connectors2 = #250 kcmil Connectors3 = #350 kcmil Connectors5 = #500 kcmil Connectors6 = #600 kcmil Connectors7 = #750 kcmil Connectors8 = Dual #250 kcmil
Connectors9 = Dual #500 kcmil
Connectors
Service Design
0 = Overhead1 = Combination Overhead/
Underground2 = Underground, Side Wired3 = Combination Overhead/
Underground, Side Wired4 = End Feed
Standard Prefix(See Prefix Guide on Page 2)
See Product Group
Designators 1
Maximum Conductor(Line & Load)
0 = 3/8 Stud Connectors1 = #2/0 Connectors2 = #250 kcmil Connectors3 = #350 kcmil Connectors5 = #500 kcmil Connectors6 = #600 kcmil Connectors7 = #750 kcmil Connectors8 = Dual #250 kcmil
Connectors9 = Dual #350 kcmil
Connectors
Cutler-Hammer
UT H 4 2 0 3 B CH
Ampere Rating
2 = 200 Amperes3 = 320 Amperes
Standard Suffixes
A = Solid TopB = Small Hub OpeningC = Small Hub Closure PlateL = 1-1/4" Hub
M = 1-1/2" HubN = 2" HubP = 2-1/2" HubT = Large Hub OpeningU = Large Hub Cover PlateV = 2-1/2" Large HubQ = 3" Large HubR = 3-1/2" Large HubS = 4" Large HubZ = Large to Small Hub Adapter Mounted
Service Design
0 = Overhead1 = Combination Overhead/
Underground2 = Underground, Side Wired3 = Combination, Overhead/
Underground, Side Wired
See Product Group
Designators 2
Jaw Quantity
4 = 4 Terminal5 = 5 Terminal7 = 7 Terminal
Standard Prefix(See Prefix Guide on Page 2)
May 2007
4
For more information visit:
www.eaton.com
TD00505006E
Metering EquipmentMeter Sockets
Product Selection by Utility
Allegheny Power Utility
Table 4. Allegheny Power Utility — Meter Socket Approval List
1
Ground connection.
2
Horn bypass.
3
Lever bypass.
Note: “100...CH”
catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system.
Table 5. Cutler-Hammer Meter Socket Accessories
Cutler-HammerCatalog Number
Description Dimensions Connections Concentric Knockouts(See Page 11)
H W D Line Load 1 2 3 4 5
100 Ampere Single-Position — Residential
UHTRS101BCH
100 A, 4 Terminal, SM Hub Open, OH/UG
12
10.88 8.00 3.50 #8 – 2/0 #8 – 2/0 1.50 1.50 2.00 1.25 —
200 Ampere Single-Position — Residential
1008941CH1008940CHUHTRS213BCH
200 A, 4 Terminal, Solid Top, UG, Offset, Left Feed
12
200 A, 4 Terminal, Solid Top, UG, Offset, Right Feed
12
200 A, 4 Terminal, SM Hub Open, OH 12
17.1317.1315.00
13.0013.0011.00
4.944.944.38
#8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
#8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
2.502.502.50
2.502.502.50
3.003.002.50
3.003.002.50
.50
.50
.50
200 Ampere Single-Position — Commercial w/ Lever BypassUTH7213B or TCH 200 A, 7 Terminal, SM or LG Hub Open, OH/UG 13 19.00 13.00 4.94 #6 – 350 kcmil #6 – 350 kcmil 3.00 2.50 3.00 3.00 .50
320 Ampere Commercial — Residential w/ Lever BypassUTH4330TCHUTH7330TCH
320 A, 4 Terminal, LG Hub Open, OH/UG 13
320 A, 7 Terminal, LG Hub Open, OH/UG 1336.6339.88
15.0020.00
5.696.50
3/8" Stud3/8" Stud
3/8" Stud3/8" Stud
3.504.00
3.504.00
3.504.00
3.504.00
.50
.50
100 Ampere Multi-Position — Residential Single-PhaseUHT2R1121BCHUHT3R1121BCHUHT4R1121BCHUHT5R1121BCHUHT6R1131BCH
100 A, 2 Position, SM Hub Open, OH, Center Feed 12
100 A, 3 Position, SM Hub Open, OH, Center Feed 12
100 A, 4 Position, SM Hub Open, OH, Center Feed 12
100 A, 5 Position, SM Hub Open, OH, Center Feed 12
100 A, 6 Position, SM Hub Open, OH, Center Feed 12
14.1314.1314.1314.1314.13
24.3132.4740.6348.7856.94
4.504.504.504.504.50
#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 350 kcmil
#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0
2.502.502.502.502.50
2.502.502.502.502.50
2.502.502.502.502.50
2.502.502.502.502.50
.50
.50
.50
.50
.50
UHT2R1421BCHUHT3R1421BCHUHT4R1421BCHUHT5R1421BCHUHT6R1431BCH
100 A, 2 Position, SM Hub Open, OH, End Feed 12
100 A, 3 Position, SM Hub Open, OH, End Feed 12
100 A, 4 Position, SM Hub Open, OH, End Feed 12
100 A, 5 Position, SM Hub Open, OH, End Feed 12
100 A, 6 Position, SM Hub Open, OH, End Feed 12
14.1314.1314.1314.1314.13
20.1628.3136.4744.6352.78
5.385.385.385.385.38
#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 350 kcmil
#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0
2.502.502.502.502.50
2.502.502.502.502.50
3.003.003.003.003.00
2.502.502.502.502.50
.50
.50
.50
.50
.50
200 Ampere Multi-Position — Residential Single-PhaseUHT2R2332TCHUHT3R2332TCHUHT4R2352TCHUHT5R2392TTCHUHT6R2392TTCH
200 A, 2 Position, LG Hub Open, OH, Center Feed 12
200 A, 3 Position, LG Hub Open, OH, Center Feed 12
200 A, 4 Position, LG Hub Open, OH, Center Feed 12
200 A, 5 Position, LG Hub Open, OH, Center Feed 12
200 A, 6 Position, LG Hub Open, OH, Center Feed 12
14.1314.1314.1314.1314.13
24.3132.4740.6354.7862.94
5.385.385.385.385.38
#6 – 350 kcmil#6 – 350 kcmil1/0 – 500 kcmil1/0 – 500 kcmil1/0 – 500 kcmil
#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil
2.502.502.502.502.50
2.502.502.502.502.50
3.003.003.003.003.00
2.502.502.502.502.50
.50
.50
.75
.75
.75
Cutler-HammerCatalog Number
Description Cutler-HammerCatalog Number
Description
ARP00003CH1ARP00004CH12ARP00005CH15ARP00006CH2ARP00007CH25
1.00-Inch Hub1.25-Inch Hub1.50-Inch Hub2.00-Inch Hub — Small Opening2.50-Inch Hub — Small Opening
ARP00008CHARP00016CHBARP00015CHAPARP00035CHJARP00039CH
Small Hub Closure Plate — AluminumLarge Hub Closure PlateHub Adapter Plate — Large to SmallReplacement — Plug-in Fifth Terminal (R and RS Models Only)Replacement Block Assembly for 100 A Sockets — 2/0 Maximum
ARP00017CH2ARP00018CH25ARP00019CH3ARP00021CH4ARP00002CHB
2.00-Inch Hub — Large Opening2.50-Inch Hub — Large Opening3.00-Inch Hub — Large Opening4.00-Inch Hub — Large OpeningSmall Hub Closure Plate
ARP00048CHARP00354CHARP00129CHARP00427CHARP00119CH
Replacement Block Assembly for 200 A Sockets — 350 MaximumReplacement Block Assembly for 150 A Sockets — 250 Maximum#4 – 600 kcmil Lug#6 – 350 kcmil Dual Lug#6 – 350 kcmil Lug
320 Ampere Lever BypassMeter Socket (UTH4330TCH)
200 Ampere Lever BypassMeter Socket (UTH7213TCH)
200 Ampere Multi-PositionMeter Socket (UHT3R2332TCH)
200 Ampere Single-PositionMeter Socket (1008941CH)
May 2007
TD00505006E For more information visit: www.eaton.com
5Metering EquipmentMeter SocketsProduct Selection by Utility
Duquesne Light Company Utility
Table 6. Duquesne Light Company Utility — Meter Socket Approval List
1 Horn bypass.Note: “100...CH” catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system.
Table 7. Cutler-Hammer Meter Socket Accessories
Cutler-HammerCatalog Number
Description Dimensions Connections Concentric Knockouts(See Page 11)
H W D Line Load 1 2 3 4 5
100 – 125 Ampere Single-Position — Residential Single-PhaseURS101BDQCH 125 A, 4 Terminal, SM Hub Open, OH 1 10.88 8.00 3.50 #8 – 2/0 #8 – 2/0 1.50 1.50 2.00 1.25 —
200 Ampere Single-Position — Residential Single-PhaseURS202BDQCH1008717CH1008819CH1008827CH
200 A, 4 Terminal, SM Hub Open, OH 1200 A, 4 Terminal, Solid Top, UG 1200 A, 4 Terminal, Solid Top, UG, Offset Right Feed 1200 A, 4 Terminal, Solid Top, UG, Offset Left Feed 1
14.0015.0013.0013.00
8.0013.0013.0013.00
4.384.944.944.94
#8 – 250 kcmil #8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
#8 – 250 kcmil #8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
2.503.002.502.50
2.503.002.502.50
2.503.003.003.00
—3.003.003.00
.50
.50
.50
.50
150 Ampere Multi-Position — Residential Single-PhaseU2R5432BDQCHU3R5432BDQCH
150 A, 2 Position, SM Hub Open, OH/UG, End Feed 1150 A, 3 Position, SM Hub Open, OH/UG, End Feed 1
14.1314.13
20.1620.16
5.385.38
#6 – 350 kcmil#6 – 350 kcmil
#8 – 250 kcmil #8 – 250 kcmil
2.502.50
2.502.50
3.003.00
2.502.50
.50
.50
200 Ampere Multi-Position — Residential Single-PhaseU2R2332TDQCHU3R2332TDQCHU4R2352TDQCHU5R2392TTDQCHU6R2392TTDQCH
200 A, 2 Position, LG Hub Open, OH, Center Feed 1200 A, 3 Position, LG Hub Open, OH, Center Feed 1200 A, 4 Position, LG Hub Open, OH, Center Feed 1200 A, 5 Position, LG Hub Open, OH, Center Feed 1200 A, 6 Position, LG Hub Open, OH, Center Feed 1
14.1314.1314.1314.1314.13
24.3132.4740.6354.7862.94
5.385.385.385.385.38
#6 – 350 kcmil#6 – 350 kcmil1/0 – 500 kcmil1/0 – 500 kcmil1/0 – 500 kcmil
#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil
2.502.502.502.502.50
2.502.502.502.502.50
3.003.003.003.003.00
2.502.502.502.502.50
.50
.50
.75
.75
.75
Cutler-HammerCatalog Number
Description Cutler-HammerCatalog Number
Description
ARP00003CH1ARP00004CH12ARP00005CH15ARP00006CH2ARP00007CH25
1.00-Inch Hub1.25-Inch Hub1.50-Inch Hub2.00-Inch Hub — Small Opening2.50-Inch Hub — Small Opening
ARP00008CHARP00016CHBARP00015CHAPARP00035CHJARP00039CH
Small Hub Closure Plate — AluminumLarge Hub Closure PlateHub Adapter Plate — Large to SmallReplacement — Plug-in Fifth Terminal (R and RS Models Only)Replacement Block Assembly for 100 A Sockets — 2/0 Maximum
ARP00017CH2ARP00018CH25ARP00019CH3ARP00021CH4ARP00002CHB
2.00-Inch Hub — Large Opening2.50-Inch Hub — Large Opening3.00-Inch Hub — Large Opening4.00-Inch Hub — Large OpeningSmall Hub Closure Plate
ARP00048CHARP00354CHARP00129CHARP00427CHARP00119CH
Replacement Block Assembly for 200 A Sockets — 350 MaximumReplacement Block Assembly for 150 A Sockets — 250 Maximum#4 – 600 kcmil Lug#6 – 350 kcmil Dual Lug#6 – 350 kcmil Lug
100 Ampere Single-PositionMeter Socket (URS101BDQCH)
200 Ampere Single-PositionMeter Socket (1008827CH)
200 Ampere Multi-PositionMeter Socket (U3R2332TDQCH)
May 2007
6
For more information visit: www.eaton.com TD00505006E
Metering EquipmentMeter SocketsProduct Selection by Utility
First Energy (GPU, JCP&L, Penelec & Met Ed)
Table 8. First Energy (GPU, JCP&L, Penelec & Met Ed) — Meter Socket Approval List
1 Ground connection.2 Horn bypass.3 Units are able to be converted to 5 terminal single-phase using field-installable kit ARP00035CHJ.4 Lever bypass.5 Anti-inversion clip installed.6 Center feed.Note: “100...CH” catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system.
Table 9. Cutler-Hammer Meter Socket Accessories
Cutler-HammerCatalog Number
Description Dimensions Connections Concentric Knockouts(See Page 11)
H W D Line Load 1 2 3 4 5
100 – 125 Ampere Single-Position — Residential1008947CH 125 A, 4 Terminal, SM Hub Open, OH/UG 12 10.88 8.00 3.50 #8 – 2/0 #8 – 2/0 1.50 1.50 2.00 1.25 —
200 Ampere Single-Position — ResidentialUHTRS202BCH 3
UHTRS213BCH 3
UHTRS223ACH 3
UBHTRS223ARHCH 3
200 A, 4 Terminal, SM Hub Open, OH 12
200 A, 4 Terminal, SM Hub Open, OH/UG 12
200 A, 4 Terminal, Solid Top, UG, Meter Right 12
200 A, 4 Terminal, Solid Top, UG, Meter Left 12
14.0015.0013.0013.00
8.0011.0013.0013.00
4.384.385.004.94
#8 – 250 kcmil #8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
#8 – 250 kcmil #8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
2.502.502.502.50
2.502.502.502.50
2.502.503.003.00
—2.502.502.50
.50
.50
.50
.50
200 Ampere Single-Position — Commercial w/ Lever BypassUTH4213B or TCHUTH5213B or TCHUTH7213B or TCH
200 A, 4 Terminal, SM or LG Hub Open, OH/UG 14
200 A, 5 Terminal, SM or LG Hub Open, OH/UG 14
200 A, 7 Terminal, SM or LG Hub Open, OH/UG 14
19.0019.0019.00
13.0013.0013.00
4.944.944.94
#6 – 350 kcmil#6 – 350 kcmil#6 – 350 kcmil
#6 – 350 kcmil#6 – 350 kcmil#6 – 350 kcmil
3.003.003.00
2.502.502.50
3.003.003.00
3.003.003.00
.50
.50
.50
320 Ampere Commercial — Residential w/ Lever Bypass1008948CH1008949CH1008950CH
320 A, 4 Terminal, LG Hub Open, OH/UG 145
320 A, 5 Terminal, LG Hub Open, OH/UG 145
320 A, 7 Terminal, LG Hub Open, OH/UG 145
36.6339.8839.88
15.0020.0020.00
5.696.506.50
3/8" Stud3/8" Stud3/8" Stud
3/8" Stud3/8" Stud3/8" Stud
3.504.004.00
3.504.004.00
3.504.004.00
3.504.004.00
.50
.50
.50
100 Ampere Multi-Position — Residential Single-Phase1008951CH1008952CH1008953CH1008954CH1008955CH
100 A, 2 Position, SM Hub Open, OH/UG 126
100 A, 3 Position, SM Hub Open, OH/UG 126
100 A, 4 Position, SM Hub Open, OH/UG 126
100 A, 5 Position, SM Hub Open, OH/UG 126
100 A, 6 Position, SM Hub Open, OH/UG 126
14.1314.1314.1314.1314.13
24.3132.4740.6348.7856.94
4.504.504.504.504.50
#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 350 kcmil
#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0
2.502.502.502.502.50
2.502.502.502.502.50
2.502.502.502.502.50
2.502.502.502.502.50
.50
.50
.50
.50
.50
200 Ampere Multi-Position — Residential Single-PhaseUHT2R2332TCHUHT3R2332TCHUHT4R2352TCHUHT5R2392TTCHUHT6R2392TTCH
200 A, 2 Position, LG Hub Open, OH/UG 126
200 A, 3 Position, LG Hub Open, OH/UG 126
200 A, 4 Position, LG Hub Open, OH/UG 126
200 A, 5 Position, LG Hub Open, OH/UG 126
200 A, 6 Position, LG Hub Open, OH/UG 126
14.1314.1314.1314.1314.13
24.3132.4740.6354.7862.94
5.385.385.385.385.38
#6 – 350 kcmil#6 – 350 kcmil1/0 – 500 kcmil1/0 – 500 kcmil1/0 – 500 kcmil
#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil
2.502.502.502.502.50
2.502.502.502.502.50
3.003.003.003.003.00
2.502.502.502.502.50
.50
.50
.75
.75
.75
Cutler-HammerCatalog Number
Description Cutler-HammerCatalog Number
Description
ARP00003CH1ARP00004CH12ARP00005CH15ARP00006CH2ARP00007CH25
1.00-Inch Hub1.25-Inch Hub1.50-Inch Hub2.00-Inch Hub — Small Opening2.50-Inch Hub — Small Opening
ARP00008CHARP00016CHBARP00015CHAPARP00035CHJARP00039CH
Small Hub Closure Plate — AluminumLarge Hub Closure PlateHub Adapter Plate — Large to SmallReplacement — Plug-in Fifth Terminal (R and RS Models Only)Replacement Block Assembly for 100 A Sockets — 2/0 Maximum
ARP00017CH2ARP00018CH25ARP00019CH3ARP00021CH4ARP00002CHB
2.00-Inch Hub — Large Opening2.50-Inch Hub — Large Opening3.00-Inch Hub — Large Opening4.00-Inch Hub — Large OpeningSmall Hub Closure Plate
ARP00048CHARP00354CHARP00129CHARP00427CHARP00119CH
Replacement Block Assembly for 200 A Sockets — 350 MaximumReplacement Block Assembly for 150 A Sockets — 250 Maximum#4 – 600 kcmil Lug#6 – 350 kcmil Dual Lug#6 – 350 kcmil Lug
100 Ampere Single-PositionMeter Socket (1008947CH)
320 Ampere Lever BypassMeter Socket (1008948CH)
200 Ampere Lever BypassMeter Socket (UTH7213TCH)
200 Ampere Single-PositionMeter Socket (UHTRS223ACH)
May 2007
TD00505006E For more information visit: www.eaton.com
7Metering EquipmentMeter SocketsProduct Selection by Utility
Pennsylvania Power & Light (PP&L)
Table 10. Pennsylvania Power & Light (PP&L) — Meter Socket Approval List
1 Ground connection.2 Horn bypass.3 Offset design.
4 Lever bypass.5 Single #600 kcmil/Dual #250 kcmil.
6 Center fed.7 Steel enclosure.
Note: “100...CH” catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system.
Table 11. Cutler-Hammer Meter Socket Accessories
Cutler-HammerCatalog Number
Description Dimensions Connections Concentric Knockouts(See Page 11)
H W D Line Load 1 2 3 4 5
100 Ampere Single-Position — Residential 1004162ACH 100 A, 4 Terminal, SM Hub Open, OH 12 10.88 8.00 3.50 #8 – 2/0 #8 – 2/0 1.50 1.50 2.00 1.25 —
200 Ampere Single-Position — Residential 1004161ACH1004884ACH1004884ARHCH1004159ACH
200 A, 4 Terminal, SM Hub Open, OH 12
200 A, 4 Terminal, Solid Top, UG, Meter Right 123
200 A, 4 Terminal, Solid Top, UG, Meter Left 123
200 A, 4 Terminal, SM Hub Cover Plate, OH/UG 12
14.0013.0013.0015.00
8.0013.0013.1311.00
4.385.004.944.38
#8 – 250 kcmil #8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
#8 – 250 kcmil #8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
2.502.502.502.50
2.502.502.502.50
2.503.003.002.50
—2.502.502.50
.50
.50
.50
.50
200 Ampere Single-Position — Commercial w/ Lever Bypass1004137ACH1004138ACH
200 A, 5 Terminal, SM Hub Open, OH/UG 4200 A, 7 Terminal, LG Hub Open, OH/UG 4
19.0034.50
13.0015.00
4.945.69
#6 – 350 kcmil#4 – 500 kcmil
#6 – 350 kcmil#4 – 500 kcmil
3.003.50
2.503.50
3.003.50
3.003.50
.50
.50
320 Ampere Commercial — Residential w/ Lever Bypass1004984ACH1008543CH
320 A, 4 Terminal, LG Hub Open, OH/UG 4320 A, 7 Terminal, LG Hub Closure Plate, UG 4
36.6339.88
15.0020.00
5.696.50
3/8" Stud5
3/8" Stud5
3.504.00
3.504.00
3.504.00
3.504.00
.50
.50
100 Ampere Multi-Position — Residential Single-Phase1004426ACH1004427ACH1004428ACH1004429ACH1004430ACH
100 A, 2 Position, SM Hub Open, OH/UG 126
100 A, 3 Position, SM Hub Open, OH/UG 126
100 A, 4 Position, SM Hub Open, OH/UG 126
100 A, 5 Position, SM Hub Open, OH/UG 126
100 A, 6 Position, SM Hub Open, OH/UG 126
14.1314.1314.1314.1314.13
24.3132.4740.6348.7856.94
4.504.504.504.504.50
#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 350 kcmil
#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0
2.502.502.502.502.50
2.502.502.502.502.50
2.502.502.502.502.50
2.502.502.502.502.50
.50
.50
.50
.50
.50
200 Ampere Multi-Position — Residential Single-Phase1004401BCH1004404BCH1004438BCH1004439BCH1004440BCH
200 A, 2 Position, LG Hub Open, OH/UG 126
200 A, 3 Position, LG Hub Open, OH/UG 126
200 A, 4 Position, LG Hub Open, OH/UG 126
200 A, 5 Position, LG Hub Open, OH/UG 126
200 A, 6 Position, LG Hub Open, OH/UG 126
14.1314.1314.1314.1314.13
24.3132.4740.6354.7862.94
5.385.385.385.385.38
#6 – 350 kcmil#6 – 350 kcmil1/0 – 500 kcmil1/0 – 500 kcmil1/0 – 500 kcmil
#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil
2.502.502.502.502.50
2.502.502.502.502.50
3.003.003.003.003.00
2.502.502.502.502.50
.50
.50
.75
.75
.75
400 – 600 Ampere — Residential/Commercial K Base Sockets — Three-PhaseCH9564K7CH9802K7
480/600 A, 7 Terminal, OH/UG, LG Hub Opening 7480/600 A, 7 Terminal, OH/UG, LG Hub Cover Plate 7
43.0037.60
20.0026.0
6.106.10
.50 – 20 Stud
.50 – 20 Stud.50 – 20 Stud.50 – 20 Stud
4.004.00
4.004.00
4.004.00
4.004.00
.75
.75
320 Ampere Lever BypassMeter Socket (1004984ACH)
200 Ampere Lever BypassMeter Socket (1004138ACH)
200 Ampere Single-PositionMeter Socket (1004884ARHCH)
200 Ampere Single-PositionMeter Socket (1004884ACH)
Cutler-HammerCatalog Number
Description Cutler-HammerCatalog Number
Description
ARP00003CH1ARP00004CH12ARP00005CH15ARP00006CH2ARP00007CH25
1.00-Inch Hub1.25-Inch Hub1.50-Inch Hub2.00-Inch Hub — Small Opening2.50-Inch Hub — Small Opening
ARP00008CHARP00016CHBARP00015CHAPARP00035CHJARP00039CH
Small Hub Closure Plate — AluminumLarge Hub Closure PlateHub Adapter Plate — Large to SmallReplacement — Plug-in Fifth Terminal (R and RS Models Only)Replacement Block Assembly for 100 A Sockets — 2/0 Maximum
ARP00017CH2ARP00018CH25ARP00019CH3ARP00021CH4ARP00002CHB
2.00-Inch Hub — Large Opening2.50-Inch Hub — Large Opening3.00-Inch Hub — Large Opening4.00-Inch Hub — Large OpeningSmall Hub Closure Plate
ARP00048CHARP00354CHARP00129CHARP00427CHARP00119CH
Replacement Block Assembly for 200 A Sockets — 350 MaximumReplacement Block Assembly for 150 A Sockets — 250 Maximum#4 – 600 kcmil Lug#6 – 350 kcmil Dual Lug#6 – 350 kcmil Lug
May 2007
8
For more information visit: www.eaton.com TD00505006E
Metering EquipmentMeter SocketsProduct Selection by Utility
Philadelphia Electric Company (PECO)
Table 12. Philadelphia Electric Company (PECO) — Meter Socket Approval List
1 Barrel lock provision.2 Horn bypass.3 Solid top.4 Lever bypass.5 Center fed.Note: “100...CH” catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system.
Table 13. Cutler-Hammer Meter Socket Accessories
Cutler-HammerCatalog Number
Description Dimensions Connections Concentric Knockouts(See Page 11)
H W D Line Load 1 2 3 4 5
100 – 125 Ampere Single-Position — Residential Single-PhaseUBHRS101BCH 125 A, 4 Terminal SM Hub Open, OH 12 10.88 8.00 3.50 #8 – 2/0 #8 – 2/0 1.50 1.50 2.00 1.25 —
200 Ampere Single-Position — Residential Single-PhaseUBHRS202BCHUBHRS212CCHUBHRS223ACHUBHTRS223ARHCH
200 A, 4 Terminal, SM Hub Open, OH 12
200 A, 4 Terminal, SM Hub Cover Plate, UG 12
200 A, 4 Terminal, Offset, UG, Meter Right 123
200 A, 4 Terminal, Offset, UG, Meter Left 123
14.0014.0013.0013.00
8.0011.0013.0013.00
4.384.384.944.94
#8 – 250 kcmil#8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
#8 – 250 kcmil#8 – 350 kcmil#8 – 350 kcmil#8 – 350 kcmil
2.502.502.502.50
2.502.502.502.50
2.503.003.002.50
—2.502.502.50
.50
.50
.50
.50
200 Ampere Single-Position — Commercial w/ Lever BypassUBH7213TCHUBC7213BCH
200 A, 7 Terminal, LG Hub Open, OH/UG 14
200 A, 7 Terminal, LG Hub Open, OH/UG 1419.0019.00
13.0013.00
4.944.94
#6 – 350 kcmil#6 – 350 kcmil
#6 – 350 kcmil#6 – 350 kcmil
3.003.00
2.502.50
3.003.00
3.003.00
.50
.50
320 Ampere Commercial — Residential w/ Lever Bypass1008435CH 320 A, 4 Terminal, UG, Ground Connection 134 26.00 15.00 5.69 #4 – 600 kcmil #4 – 600 kcmil 3.50 3.50 3.50 3.50 .50
100 Ampere Multi-Position Sockets — Residential Single-PhaseUBH2R1121BCHUBH3R1121BCHUBH4R1121BCHUBH5R1121BCHUBH6R1131BCH
100 A, 2 Position, SM Hub Open, OH/UG 125
100 A, 3 Position, SM Hub Open, OH/UG 125
100 A, 4 Position, SM Hub Open, OH/UG 125
100 A, 5 Position, SM Hub Open, OH/UG 125
100 A, 6 Position, SM Hub Open, OH/UG 125
14.1314.1314.1314.1314.13
24.3132.4740.6348.7856.94
4.504.504.504.504.50
#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 250 kcmil#6 – 350 kcmil
#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0#8 – 2/0
2.502.502.502.502.50
2.502.502.502.502.50
2.502.502.502.502.50
2.502.502.502.502.50
.50
.50
.50
.50
.50
200 Ampere Multi-Position Sockets — Residential Single-PhaseUBH2R2332TCHUBH3R2332TCHUBH4R2352TCHUBH5R2392TTCHUBH6R2392TTCH
200 A, 2 Position, LG Hub Open, OH/UG 125
200 A, 3 Position, LG Hub Open, OH/UG 125
200 A, 4 Position, LG Hub Open, OH/UG 125
200 A, 5 Position, LG Hub Open, OH/UG 125
200 A, 6 Position, LG Hub Open, OH/UG 125
14.1314.1314.1314.1314.13
24.3132.4740.6354.7862.94
5.385.385.385.385.38
#6 – 350 kcmil#6 – 350 kcmil1/0 – 500 kcmil1/0 – 500 kcmil1/0 – 500 kcmil
#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil
2.502.502.502.502.50
2.502.502.502.502.50
3.003.003.003.003.00
2.502.502.502.502.50
.50
.50
.75
.75
.75
Cutler-HammerCatalog Number
Description Cutler-HammerCatalog Number
Description
ARP00003CH1ARP00004CH12ARP00005CH15ARP00006CH2ARP00007CH25
1.00-Inch Hub1.25-Inch Hub1.50-Inch Hub2.00-Inch Hub — Small Opening2.50-Inch Hub — Small Opening
ARP00008CHARP00016CHBARP00015CHAPARP00035CHJARP00039CH
Small Hub Closure Plate — AluminumLarge Hub Closure PlateHub Adapter Plate — Large to SmallReplacement — Plug-in Fifth Terminal (R and RS Models Only)Replacement Block Assembly for 100 A Sockets — 2/0 Maximum
ARP00017CH2ARP00018CH25ARP00019CH3ARP00021CH4ARP00002CHB
2.00-Inch Hub — Large Opening2.50-Inch Hub — Large Opening3.00-Inch Hub — Large Opening4.00-Inch Hub — Large OpeningSmall Hub Closure Plate
ARP00048CHARP00354CHARP00129CHARP00427CHARP00119CH
Replacement Block Assembly for 200 A Sockets — 350 MaximumReplacement Block Assembly for 150 A Sockets — 250 Maximum#4 – 600 kcmil Lug#6 – 350 kcmil Dual Lug#6 – 350 kcmil Lug
320 Ampere Lever Bypass Meter Socket (UBH7213TCH)
200 Ampere Single-Position Meter Socket (UBHRS223ACH)
100 Ampere Single-PositionMeter Socket (UBHRS101BCH)
200 Ampere Single-Position Meter Socket (UBHTRS223ARHCH)
May 2007
TD00505006E For more information visit: www.eaton.com
9Metering EquipmentMeter SocketsProduct Selection by Utility
Atlantic City Electric/Delmarva Utility
Table 14. Atlantic City Electric/Delmarva Utility — Meter Socket Approval List
1 Ground connection.2 Horn bypass.3 Inhibitor provided on jaws.4 Lever bypass.5 For 3 and 5 gang units, use 4 or 6 gang respectively.Note: “100...CH” catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system.
Table 15. Cutler-Hammer Meter Socket Accessories
Cutler-HammerCatalog Number
Description Dimensions Connections Concentric Knockouts(See Page 11)
H W D Line Load 1 2 3 4 5
200 Ampere Single-Position — Residential Single-PhaseUHIRS213BCVCHUHIRS223ACVCH
200 A, 5 Terminal, SM Hub Open, OH 123
200 A, 5 Terminal, SM Hub Cover Plate, UG 12315.0013.00
11.0013.00
4.384.94
#8 – 350 kcmil#8 – 350 kcmil
#8 – 350 kcmil#8 – 350 kcmil
2.502.50
2.502.50
2.503.00
—2.50
.50
.50
200 Ampere Single-Position — Commercial w/ Lever BypassUIH5213UCVCHUIH7213UCVCH
200 A, 5 Terminal, SM Hub Closure Plate OH/UG 134
200 A, 7 Terminal, LG Hub Closure Plate OH/UG 13419.0019.00
13.0013.00
4.944.94
#6 – 350 kcmil#6 – 350 kcmil
#6 – 350 kcmil#6 – 350 kcmil
3.003.00
2.502.50
3.003.00
3.003.00
.50
.50
320 Ampere Commercial — Residential Single-Phase w/ Lever Bypass1009444CH 320 A, 4 Terminal, LG Hub Cover Plate OH/UG 134 36.63 15.00 5.69 3/8-Inch Stud 3/8-Inch Stud 3.50 3.50 3.50 3.50 .50
100 Ampere Multi-Position Sockets — Residential Single-PhaseUse 200 Ampere
200 Ampere Multi-Position Sockets — Residential Single-Phase 5
UHI2R2332TCVCHUHI4R2352TCVCHUHI6R2392TTCVCH
200 A, 2 Position, LG Hub Open, OH, Ctr Fed 123
200 A, 4 Position, LG Hub Open, OH, Ctr Fed 123
200 A, 6 Position, LG Hub Open, OH, Ctr Fed 123
14.1314.1314.13
24.3140.6362.94
5.385.385.38
#6 – 350 kcmil1/0 – 500 kcmil1/0 – 500 kcmil
#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil
2.502.502.50
2.502.502.50
3.003.003.00
2.502.502.50
.50
.75
.75
UHI2R2332ACVCHUHI4R2352ACVCHUHI6R2392ACVCH
200 A, 2 Position, Solid Top, UG, Ctr Fed 123
200 A, 4 Position, Solid Top, UG, Ctr Fed 123
200 A, 5 Position, Solid Top, UG, Ctr Fed 123
14.1314.1314.13
24.3140.6362.94
5.385.385.38
#6 – 350 kcmil1/0 – 500 kcmil1/0 – 500 kcmil
#8 – 250 kcmil#8 – 250 kcmil#8 – 250 kcmil
2.502.502.50
2.502.502.50
3.003.003.00
2.502.502.50
.50
.75
.75
Cutler-HammerCatalog Number
Description Cutler-HammerCatalog Number
Description
ARP00003CH1ARP00004CH12ARP00005CH15ARP00006CH2ARP00007CH25
1.00-Inch Hub1.25-Inch Hub1.50-Inch Hub2.00-Inch Hub — Small Opening2.50-Inch Hub — Small Opening
ARP00008CHARP00016CHBARP00015CHAPARP00035CHJARP00039CH
Small Hub Closure Plate — AluminumLarge Hub Closure PlateHub Adapter Plate — Large to SmallReplacement — Plug-in Fifth Terminal (R and RS Models Only)Replacement Block Assembly for 100 A Sockets — 2/0 Maximum
ARP00017CH2ARP00018CH25ARP00019CH3ARP00021CH4ARP00002CHB
2.00-Inch Hub — Large Opening2.50-Inch Hub — Large Opening3.00-Inch Hub — Large Opening4.00-Inch Hub — Large OpeningSmall Hub Closure Plate
ARP00048CHARP00354CHARP00129CHARP00427CHARP00119CH
Replacement Block Assembly for 200 A Sockets — 350 MaximumReplacement Block Assembly for 150 A Sockets — 250 Maximum#4 – 600 kcmil Lug#6 – 350 kcmil Dual Lug#6 – 350 kcmil Lug
200 Ampere Single-Position Meter Socket (UHIRS213BCVCH)
320 Ampere Lever Bypass Meter Socket (1009444CH)
200 Ampere Single-Position Meter Socket
200 Ampere Lever BypassMeter Socket (UIH5213UCVCH)
May 2007
10
For more information visit: www.eaton.com TD00505006E
Metering EquipmentMeter SocketsProduct Selection by Utility
Delaware Electric Co-Op
Table 16. Delaware Electric Co-Op — Meter Socket Approval List
1 Ground connection.2 Horn bypass.3 Lever bypass.
Table 17. Cutler-Hammer Meter Socket Accessories
Cutler-HammerCatalog Number
Description Dimensions Connections Concentric Knockouts(See Page 11)
H W D Line Load 1 2 3 4 5
100 – 125 Ampere Single-Position — Residential Single-PhaseUHTRS101BCHUHTRS101LCH
125 A, 4 Terminal, SM Hub Open, OH/UG 12
125 A, 4 Terminal, 1.25-Inch Hub Installed, OH/UG 1210.8810.88
8.008.00
3.503.50
#8 – 2/0#8 – 2/0
#8 – 2/0#8 – 2/0
1.501.50
1.501.50
2.002.00
1.251.25
——
200 Ampere Single-Position — Residential Single-PhaseUHTRS202BCHUHTRS213CCH
200 A, 4 Terminal, SM Hub Open, OH 12
200 A, 4 Terminal, SM Hub Cover Plate, OH/UG 1214.0015.00
8.0011.00
4.384.38
#8 – 250 kcmil#8 – 350 kcmil
#8 – 250 kcmil#8 – 350 kcmil
2.502.50
2.502.50
2.502.50
2.502.50
.50
.50
200 Ampere Single-Position — Commercial w/ Lever BypassUTH7213C or UCH 200 A, 7 Terminal, Hub Closure Plate, OH/UG 13 19.00 13.00 4.94 #6 – 350 kcmil #6 – 350 kcmil 3.00 2.50 3.00 3.00 .50
320 Ampere Commercial — Residential Single-Phase w/ Lever BypassUTH4300UCHUTH4330UCHUTH7300UCHUTH7330UCH
320 A, 4 Terminal, LG Hub Cover Plate, OH 13
320 A, 4 Terminal, LG Hub Cover Plate, OH/UG 13
320 A, 7 Terminal, LG Hub Cover Plate, OH 13
320 A, 7 Terminal, LG Hub Cover Plate, OH/UG 13
34.5036.6334.5039.88
13.0015.0015.0020.00
4.945.695.696.50
3/8-Inch Stud3/8-Inch Stud3/8-Inch Stud3/8-Inch Stud
3/8-Inch Stud3/8-Inch Stud3/8-Inch Stud3/8-Inch Stud
3.003.503.504.00
3.003.503.504.00
3.003.503.504.00
3.003.503.504.00
.50
.50
.50
.50
Cutler-HammerCatalog Number
Description Cutler-HammerCatalog Number
Description
ARP00003CH1ARP00004CH12ARP00005CH15ARP00006CH2ARP00007CH25
1.00-Inch Hub1.25-Inch Hub1.50-Inch Hub2.00-Inch Hub — Small Opening2.50-Inch Hub — Small Opening
ARP00008CHARP00016CHBARP00015CHAPARP00035CHJARP00039CH
Small Hub Closure Plate — AluminumLarge Hub Closure PlateHub Adapter Plate — Large to SmallReplacement — Plug-in Fifth Terminal (R and RS Models Only)Replacement Block Assembly for 100 A Sockets — 2/0 Maximum
ARP00017CH2ARP00018CH25ARP00019CH3ARP00021CH4ARP00002CHB
2.00-Inch Hub — Large Opening2.50-Inch Hub — Large Opening3.00-Inch Hub — Large Opening4.00-Inch Hub — Large OpeningSmall Hub Closure Plate
ARP00048CHARP00354CHARP00129CHARP00427CHARP00119CH
Replacement Block Assembly for 200 A Sockets — 350 MaximumReplacement Block Assembly for 150 A Sockets — 250 Maximum#4 – 600 kcmil Lug#6 – 350 kcmil Dual Lug#6 – 350 kcmil Lug
200 Ampere Single-Position Meter Socket (UHTRS213CCH)
200 Ampere Lever Bypass Meter Socket (UTH7213CCH)
100 Ampere Single-PositionMeter Socket (UHTRS101BCH)
320 Ampere Lever BypassMeter Socket (UTH4330VCH)
May 2007
TD00505006E For more information visit: www.eaton.com
11Metering EquipmentMeter SocketsTechnical Data
Knockout Drawings
Figure 1. Knockout Drawings
1 2
3 44
1 2
31
3 44
2
1
3 44
2
1 1 1 2
34 4 4
1 1 1 2
34 4 4
2
1 2
3 4
UHTRS101BCH
UHTRS202BCH
UBHTRS223ARHCH
UTH433OTCH
UHT3R1121BCH
UHT3R2332TCH
UTH5213B or TCH
Drawings not to scale.
UHTRS223ACH
May 2007
12
For more information visit: www.eaton.com TD00505006E
Metering EquipmentGroup MeteringMeter Packs
Product Description
Meter Pack
■ Cutler-Hammer 1MP units by Eaton Electrical are self-contained (main terminal box included) for installa-tions requiring up to six meter socket positions in a single enclosure.
■ Units are not gangable with any other metering device.
■ Approved by major power compa-nies, UL listed, suitable as service equipment and meets the service and electrical requirements of EUSERC and CECHA.
■ Series rating up to 100 kAIC.■ All ringless cover devices include
fifth jaw as standard.■ Ring type devices do not include
fifth jaw as standard. Order 1MM5JK if needed.
■ Bondable neutral.■ 120/240 Vac, single-phase, 3-wire
metering device.■ Up to 600 amperes maximum
horizontal bus rating.■ Incoming lugs not included (phase
A, phase B, and neutral).■ Indoor/outdoor construction.■ Provision for 2-pole breaker
(plug-on type for 125 ampere sockets and bolt-on type for 200 ampere sockets) — circuit breakers not included.
■ Underground incoming feed.■ Aluminum or copper bus.
Product SelectionTable 18. Meter Pack Catalog Numbering System
When Ordering:
1. Determine catalog number of the basic device.
2. Include Lug Kit for incoming section. See Table 22.
3. Find quantity and catalog numbers for tenant circuit breakers. (Order one breaker per socket.) See Page 14.
4. Select required accessories. See Page 17.
Table 19. Meter Packs — Aluminum Bus
1 See Table 24.2 Fifth jaw factory installed at 9 o’clock position.3 Main lugs included. #6 – 300 kcmil. (Optional lugs are not available.)4 Bottom feed only.5 CECHA approved.Note: See Table 22 for Main Lug Kit Selection. See Table 23 for Wire Sizes.
SocketAmpereRating
Numberof MeterSockets
BusAmpereRating
Main Tenant Breaker Type1
CatalogNumber
Semi-flushFlange KitCatalog Number
Ringless Style Meter Socket Covers 2
125 223456
200200400400600600
Plug-on TypePlug-on TypeBR_BRH_BRHH_—
1MP2122RRL 34
1MP2122RRLC1MP3124RRL1MP4124RRL1MP5126RRL1MP6126RRL
1MPSFK11MPSFK11MPSFK21MPSFK21MPSFK31MPSFK3
200 23456
400600600600600
Bolt-on TypeCC2_XCHH2_H2XCHH2_H4XCHH_X
1MP2204RRL1MP3206RRL1MP4206RRL1MP5206RRL1MP6206RRL
1MPSFK41MPSFK51MPSFK51MPSFK61MPSFK6
Ringless Style Covers with Horn Bypass 2
125 223456
200200400400600600
Plug-on TypePlug-on TypeBR_BRH_BRHH_—
1MP2122RRLB 345
1MP2122RRLBC 5
1MP3124RRLB 5
1MP4124RRLB 5
1MP5126RRLB 5
1MP6126RRLB 5
1MPSFK11MPSFK11MPSFK21MPSFK21MPSFK31MPSFK3
200 23456
400600600600600
Bolt-on TypeCC2_XCHH2_H2XCHH2_H4XCHH_X
1MP2204RRLB 5
1MP3206RRLB 5
1MP4206RRLB1MP5206RRLB 5
1MP6206RRLB 5
1MPSFK41MPSFK51MPSFK51MPSFK61MPSFK6
Bus Material
C = Copper BusBlank = Aluminum Bus
1 M P 4 12 4 R C
1-Phase Metering Type
MP = Meter Pack
Number of Meters
2, 3, 4, 5 or 6Blank = Accessory
Bus Ampere Rating
2 = 200 Amperes4 = 400 Amperes6 = 600 Amperes
Blank = Accessory
Ampere Rating
12 = 125 Amperes20 = 200 Amperes
Blank = Accessory
Security or Accessory Code
R = RingRRL = Ringless
RRLB = Ringless with Horn BypassLK = Lug Kit (Accessory)SC = Crimp Lug Landing Pad Kit (Accessory)
May 2007
TD00505006E For more information visit: www.eaton.com
13Metering EquipmentGroup MeteringMeter Packs
Table 20. Meter Packs — Copper Bus
1 See Table 24.2 Fifth jaw factory installed at 9 o’clock position.3 CECHA approved.
Table 21. CECHA Approved Meter Socket Accessories
4 Bottom raceway adapter plates required.
Table 22. Main Lug Kit Selection — Field Installed Kits for Either 400 or 600 Ampere Main Bus
5 This lug is not UL listed.6 This kit comes with three pads for two lines and neutral. Each pad
will accept one or two crimp lugs. Cannot be used on 1MP2122R, RL and RLB EUSERC underground termination.
Table 23. Wire Sizes — Neutral and Ground Lugs
Note: Each stack includes a neutral and ground bar. If an extra ground bar is needed, order 1MMGBK.
SocketAmpereRating
Numberof MeterSockets
BusAmpereRating
MainTenantBreakerType 1
CatalogNumber
Semi-flushFlange KitCatalogNumber
Ringless Style Meter Socket Covers 2
125 345 6
400400600600
Plug-on TypeBR_BRH_BRHH_
1MP3124RRLC1MP4124RRLC1MP5126RRLC1MP6126RRLC
1MPSFK21MPSFK21MPSFK31MPSFK3
200 23456
400600600600600
Bolt-on TypeCC2_XCHH2_H2XCHH2_H4XCHH_X
1MP2204RRLC1MP3206RRLC1MP4206RRLC1MP5206RRLC1MP6206RRLC
1MPSFK41MPSFK51MPSFK51MPSFK61MPSFK6
Ringless Style Covers with Horn Bypass 23
125 3456
400400600600
Plug-on TypeBR_BRH_BRHH_
1MP3124RRLBC1MP4124RRLBC1MP5126RRLBC1MP6126RRLBC
1MPSFK21MPSFK21MPSFK31MPSFK3
200 23456
400600600600600
Bolt-on TypeCC2_XCHH2_H2XCHH2_H4XCHH_X
1MP2204RRLBC1MP3206RRLBC1MP4206RRLBC1MP5206RRLBC1MP6206RRLBC
1MPSFK41MPSFK51MPSFK51MPSFK61MPSFK6
Description CatalogNumber
Pedestal Trough Raceway for Underground Services 4
36.00-Inch Pedestal Trough Raceway(36.00" H 9.00" W 4.25" D)
1008934CH
Adapter PlatesAdapter Plate for 2 – 4 GangAdapter Plate for 5 – 6 Gang
1MP34EW1251MP56EW125
Line Lug and Wire SizesOrder Separately and Field Install
Line Lug Kit Catalog NumberOrder Three Kits(For Two Lines and Neutral)
(1) #6 – 600 kcmil or (2) 2/0 – 250 kcmil(2) 250 – 500 kcmil(3) #4 – 300 kcmil(1) 750 kcmilCrimp lug landing pad 250 – 750 kcmil
1MPLK11MPLK31MPLK4 1MPLK2 5
1MPSC1 6
Description Wire Size,Al/Cu
CatalogNumber
Neutral:125 ampere meter pack200 ampere meter pack
#6 – 2/0#1/0 – 300 kcmil
——
Equipment Ground Bar:125 ampere meter pack200 ampere meter pack
#14 – #2#14 – 2/0
——
Optional Ground Bar #6 – 2/0 1MMGBK
May 2007
14
For more information visit: www.eaton.com TD00505006E
Metering EquipmentGroup MeteringMain Tenant Circuit Breakers
Product Description
1MP, 1MM and 3MMMain Tenant Circuit BreakersThe following Cutler-Hammer breakers are to be used on 1MP, 1MM and 3MM modular metering stacks. They are120/240 Vac — field installed.
BR2100 CC2200
Product SelectionTable 24. 1MP, 1MM and 3MM Main Tenant Circuit BreakersDescription Number
ofPoles
Main TenantCircuit BreakerAmpere Rating
Catalog Number
10,000 AIC 22,000 AIC 25,000 AIC 42,000 AIC 100,000 AIC
Plug-on type circuit breakers used with 1MP, 1MM and 3MM 125 ampere modular metering stacks
222
60 70 80
BR260BR270BR280
BRH260BRH270BRH280
———
BRHH260BRHH270BRHH280
———
2222
90100110125
BR290BR2100BR2110BR2125
BRH290BRH2100BRH2110BRH2125
————
BRHH290BRHH2100BRHH2110BRHH2125
————
Bolt-on type circuit breakers used with 1MP, 1MM and 3MM 200 ampere modular metering stacks
222
60 70 80
———
———
CHH2060H2XCHH2070H2XCHH2080H2X
CHH2060H4XCHH2070H4XCHH2080H4X
CHH2060XCHH2070XCHH2080X
222
90100125
—CC2100XCC2125X
———
CHH2090H2XCHH2100H2XCHH2125H2X
CHH2090H4XCHH2100H4XCHH2125H4X
CHH2090XCHH2100XCHH2125X
222
150175200
CC2150XCC2175XCC2200X
———
CHH2150H2XCHH2175H2XCHH2200H2X
CHH2150H4XCHH2175H4XCHH2200H4X
CHH2150XCHH2175XCHH2200X
May 2007
TD00505006E For more information visit: www.eaton.com
15Metering EquipmentGroup MeteringMain Tenant Circuit Breakers
Dimensions and Knockouts (in Inches) — 1MP Meter Packs — Aluminum and Copper Bus
Figure 2. 125 Ampere Maximum Tenant Breaker
3.000
.450
"Z""Y"
"X""W"
Concentric Knockouts2-1/2", 3", 3-1/2", 4 " Knockout
Concentric Knockouts1", 1-1/4", 1-1/2", Knockout
ConcentricKnockouts1/2" Knockout
4.555 14.460
7.00
54.
690
3.61
5
24.080
5.125 5.610
3.62
57.01
5
Concentric Knockouts2-1/2", 3", 3-1/2", 4 " Knockout
Concentric Knockouts1", 1-1/4", 1-1/2", Knockout
Concentric Knockouts1/2" Knockout
.450
4.565
3.0008.000
3.000
36.130
6.56
0
"Z""Y""X""W"
.69527.000
4.69
0
5.6105.125
3, 4 Meter Device
12.5
529.
000
9.00
09.
000
48.2
90
24.260
To
of W
all M
tg. S
crew
C L
Met
er T
o
Rai
l Mtg
. Scr
ewC L
C L
21
.699
7.015(3) Knockout
for 1, 1-1/4, 1-1/2Conduit
(1) Knockout for 1-1/2, 2, 2-1/2 Conduit
34.2
50
2.025
3.1405, 6 Meter Device
12.5
509.
000
9.00
0
41.6
00
36.280
2.560 5.0009.380
11.880Mtn. for 2, 2-1/2, 3"C-H Conduit Hubs
1, 1-1/4, 1-1/2" KO6 Places
2.750
2.880
2.620
1.500
2.330
.880
4.360
2.300
1-1/2, 2, 2-1/2, 3" KO
57 Mtg Holes4 Places
34.1
80 23.7
50
1.806
6.3805.900 .060
2.250
2.750
1.440
1.880
of 1/2" Ringof 1-1/2" Ringof 1-1/2" Ringof 4" Ring
CLCL
CL
CL
"Z" ="Y" ="X" =
"W" =
125 Ampere Meter Packs
May 2007
16
For more information visit: www.eaton.com TD00505006E
Metering EquipmentGroup MeteringMeter Packs
Figure 3. 200 Ampere Maximum Tenant Breaker
3.000 3.000 5.610 .450
"Z""Y"
"X""W"
Concentric Knockouts2-1/2", 3", 3-1/2", 4 " Knockout
Concentric Knockouts1", 1-1/4", 1-1/2", 2" Knockout
Concentric Knockouts1/2" Knockout
4.565
4.69
0
6.55
5
.6953.625
38.635
27.000
7.01
5
8.000
4.69
0
7.00
5
Concentric Knockouts2-1/2", 3", 3-1/2", 4 " Knockout
Concentric Knockouts1", 1-1/4", 1-1/2", 2" Knockout
Concentric Knockouts1/2" Knockout
5.610.450
4.555
3.0005.125
"Z""Y""X"
"W"
3.615
Typ.
15.000
24.080
7.015 (4) Knock OutFor 1, 1-1/4, 1-1/2
Conduit 3, 4 Meter Device
15.8
26
2.015
25.480
3.125
18.4
2512
.125
12.1
2512
.125
64.5
35
To
of W
all M
tg. S
crew
C L Met
er T
o
Rai
l Mtg
. Scr
ewC L
C L
34.2
50
38.755
2.015
12.1
2512
.125
18.4
25
52.4
15
5, 6 Meter Device 2 Meter Device
25.480
2.015
42.6
85
12.1
5518
.400
of 1/2" Ringof 1-1/2" Ringof 1-1/2" Ringof 4" Ring
CLCL
CL
CL
"Z" ="Y" ="X" =
"W" =5 & 6 Meter Endwall 2 & 4 Meter Endwall
200 Ampere Meter Packs
TD00505006E For more information visit: www.eaton.com
17Metering Equipment
May 2007Group MeteringAccessories
Meter PacksTable 25. Accessories for 1MP, 1MM and 3MM Modular Metering Stacks
INNER-TITE is a registered trademark of Inner-Tite Corp. Lexan is a registered trademark of General Electric Co., USA. UL is a registered trademark of Underwriters Laboratories Inc.
Description Application Catalog Number
Fifth Jaw Kit Bolted onto neutral in the 3, 6 or 9 o’clock position. Typically used on network metering systems (3-phase in/single-phase out) or when specified by utility company.
1MM5JK
Isolated Fifth Jaw Kit Connects to the neutral with an insolated wire. 1MM5JKOP
Horn Bypass Used only on ringless cover stacks, kits can be installed on 125 ampere or 200 ampere sockets.Note: For 1MP2122RRL use:
1MMBPH
WCG8HB
Meter Bypass Jumper Installed on 125 ampere or 200 ampere sockets. Jumpers are plugged into jaws. Order LexanT cover plate with bypass jumpers to prevent accessto meter socket once energized. (Not UL listed.)
1MMBPJ
Lexan Blank Cover Circular cover mounted on ring or ringless devices preventing access to meter socket while meter is not in place. Includes 4 plastic tabs which plug into each jaw.
1MMPCP
Same as 1MMPCP minus the tabs located in the back to plug into jaws. This device to be used while meter bypass jumpers are in place (1MMBPJ).
1MMACP
Blank Meter Socket Cover Used for 125 ampere stacks. Fits bottom socket only. Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal.
1MMBC125B
Used on 200 ampere stacks. Fits bottom socket only. Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal.
1MMBC200B
Wall Mounting Rail Rails are 4 feet (1.2 m) in length. Bolted on wall for stacks, packs, and mains to be hung.
1MMWB
Bussed Spacer Bussed spacer 1200 ampere 4-inch (101.6 mm). Required when stacks are mounted on right-hand side in EUSERC areas. (Copper)
3MMBSK
Bus Duct Riser/Meter Center Connection
Available in 400, 600, 800 ampere Main Fusible units only. Contact Product Line for details.
—
Lexan Blank Cover
Bussed Spacer
Wall Mounting Rail
Horn Bypass Kit
Fifth Jaw Kit
May 2007