contents reduced voltage motor starters

32
April 2007 CA03902004E For more information visit: www.eaton.com Contents Reduced Voltage Motor Starters 1 Reduced Voltage Motor Starters Description Page Type S811, Intelligent Technologies (IT.) Soft Starters with DIM Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Instructional Leaflets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 IT. Solid-State Soft Starters — Enclosed Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Non-combination Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Combination with Fusible Disconnect Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Combination with Breaker Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Note: Supplement to Publication No. CA08102001E — Tab 39. S811 IT. Soft Starter

Upload: others

Post on 14-Apr-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit:

www.eaton.com

Contents

Reduced Voltage Motor Starters 1

Red

uce

d V

olt

ag

eM

oto

r S

tart

ers

Description Page

Type S811, Intelligent Technologies

(

IT.

)

Soft Starters with DIM

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

Instructional Leaflets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

IT.

Solid-State Soft Starters — Enclosed

Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

25

Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26

Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

27

Non-combination

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

Combination with Fusible Disconnect

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

29

Combination with Breaker

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

30

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31

Note:

Supplement to Publication No. CA08102001E — Tab 39.

S811 IT. Soft Starter

Page 2: Contents Reduced Voltage Motor Starters

April 2007

2

For more information visit:

www.eaton.com

CA03902004E

Reduced Voltage Motor StartersSolid-State Starters

Type S811, Intelligent Technologies

(IT.)

Soft Starters with DIM

Contents

Description Page

Type S811, Intelligent Technologies

(

IT.

)

Soft Starters with DIM

Product Description . . . . . . .

2

Application Description . . . .

2

Features and Benefits . . . . . .

4

Operation . . . . . . . . . . . . . . .

7

Catalog Number Selection . . . . . . . . . . . . . . .

8

Product Selection . . . . . . . . .

9

Options . . . . . . . . . . . . . . . . .

19

Accessories . . . . . . . . . . . . . .

19

Standards and Certifications . . . . . . . . . . .

20

Instructional Leaflets . . . . . .

20

Technical Data andSpecifications . . . . . . . . . . .

21

Dimensions . . . . . . . . . . . . . .

22

Product Description

Eaton’s Cutler-Hammer

®

IT.

S801 revolutionized the reduced voltage control marketplace with its advanced feature set and small size. In fact, readers of an industry leading control publication rated Cutler-Hammer Soft Starters best in customer satisfaction in March 2004 and April 2006. The new

IT.

S811 from Eaton’s electrical busi-ness offers all the popular features of the S801, but adds enhanced function-ality with the new DIM (Digital Inter-face Module), communications, metering, monitoring and diagnostics capabilities.

The Cutler-Hammer Intelligent Technologies (

IT.

) Line of S811 Reduced Voltage Soft Starters is very compact, multi-functional, easy to install and easy to program. Designed to control the acceleration and deceleration of three-phase motors up to 690V, the line is available from 11 amps through 1,000 amps.

The S811 is designed to be a complete package combining the SCRs, bypass contactor and overload in one, very compact unit. The S811 is available as a component for panel mounting, in motor control centers or in enclosed control (NEMA Type 1, 3R, 4, 4X, 7/9 and 12).

Application Description

Designed to control the acceleration and deceleration of three-phase motors, the

IT.

S811 soft starter uses Silicon Controlled Rectifiers (SCRs) to control the voltage to soft start and soft stop the motor. After the motor is started, internal run bypass contactors close, resulting in the motor running directly across-the-line. The built-in solid-state overload protects the motor from overload conditions with sophis-ticated algorithms that model true motor heating, resulting in better motor protection and fewer nuisance trips. Advanced protective and diag-nostic features reduce downtime.

A voltage ramp start or current limit start is available. Kick start is available in either starting mode. The soft stop option allows for a ramp stop time that is longer than the coast to stop time. The pump control option provides a smooth transition for starting and stopping a motor and eliminating the “water-hammer” effect that can damage pipes, valves and pumps.

The S811 offers an impressive array of advanced protective features. Not only are the protective features selectable, but many offer variable settings allow-ing the user to fine tune the starter to meet specific system requirements.

The S811 has an easy to use Digital Interface Module (DIM) that allows the user to configure the device and to read system parameters. The DIM includes an LCD display and keypad to scroll through the various menus. The DIM allows the user to modify control parameters, enable or disable protec-tions, set communication variables, monitor system parameters such as line voltages and currents, and access the fault queue.

Figure 1. Digital Interface Module (DIM)

The DIM can be removed from the S811 and remote mounted. Kits are available to door mount the DIM, enabling users to safely configure, commission, monitor and trouble-shoot the system at the electrical panel without opening the enclosure door. This will help eliminate the possibility of an arc flash incident.

S811 Open Soft Starter

ESC

ONLN SS OXFDO1 H STOP

Monitoring

PREV NEXT ENTER

Page 3: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit:

www.eaton.com

3Reduced Voltage Motor StartersSolid-State Starters

Type S811, Intelligent Technologies

(IT.)

Soft Starters with DIM

Communications

The S811 has built-in communication capabilities through Cutler-Hammer QC (Quick Connect) Port. QCPort enables the soft starter to be con-nected to a variety of networks, includ-ing DeviceNet™, EtherNet/Modbus, EtherNet/IP and PROFIBUS. The advantage of QCPort is that multiple control components can be connected to one Cutler-Hammer

IT.

D77D gate-way. The gateway concentrates data from the devices into a single node. Configuration is simple — a single press of the gateway’s Auto Configura-tion button sets the system up for default operation. This automatically configures the I/O assemblies to the QCPort system devices. The data from these devices are then assembled into single input and output messages.

The S811 communication parameters can be configured with the DIM or through the fieldbus using CH Studio Component Manager. Advanced communication configuration settings provide the system integrator with powerful tools to facilitate system optimization.

Figure 2. S811 Connection Diagram

Table 1. Communications Reference

See Tab 50 of CA08102001E.

See Tab 44 of CA08102001E.

FieldBus

DIM

NetworkAdapter

(Gateway)

Terminator&

Power Tap

DIN RailCommunications

Backplane

24V DCPowerSupply

+– 1 0

IT. S811 Soft Starter

Description PartNumber

CatalogPage

DeviceNet Network Adapter

D77D-DNA

EtherNet Modbus Network Adapter

D77D-EMA

EtherNet/IP Network Adapter

D77D-EIP

PROFIBUS Network Adapter

D77D-PNA

Terminator and Power Tap

D77E-QPLR

DIN Rail Communications Backplane, 7-position

D77E-BP7

DIN Rail Communications Backplane, 12-position

D77E-BP12

24V DC Power Supply (120V AC Input)

PSS55A

24V DC Power Supply (240V AC Input)

PSS55B

24V DC Power Supply (480V AC Input)

PSS55C

Page 4: Contents Reduced Voltage Motor Starters

April 2007

4

For more information visit:

www.eaton.com

CA03902004E

Reduced Voltage Motor StartersSolid-State Starters

Type S811, Intelligent Technologies

(IT.)

Soft Starters with DIM

Features and Benefits

The DIM (Digital Interface Module) provides an intuitive, easy-to-use human interface with powerful con-figuration capabilities to maximize system performance.

Door or device mounted DIM enables users to safely configure, commission, monitor and trouble-shoot the system at the electrical panel without opening the enclo

sure door, eliminating the possibility

of an arc flash incident.

System operating parameters can be monitored enterprise-wide through a communications network. Increase uptime by providing data for process management and preventive diagnostics.

Run bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs. Bypass contactor directly connects the motor to the line and improves system efficiency by reducing internal power losses.

Internal solid-state overload protec-tion provides accurate current mea-surement and trip settings. Sophisticated algorithms solve a series of differential equations that model true motor heating and cool-ing, resulting in superior motor overload protection while minimiz-ing nuisance trips. Advanced select-able protective features safeguard the motor and system against a variety of system faults.

Internal run bypass contactors and overload protection eliminate the need for additional devices, reduc-ing enclosure sizes, minimizing installation and wiring time and reducing overall assembly size and cost.

Wide range of overload FLA settings (31 – 100% of rated current) and a selectable trip class (5 – 30) offers users the flexibility to fine tune the starter to match specific application requirements.

Variable ramp times and torque con-trol settings provide unlimited start-ing configurations, allowing for maximum application flexibility.

Kick-start feature enables soft start-ing of high friction loads.

Soft stop control for applications where an abrupt stop of the load is not acceptable.

Pump control option with sophisti-cated pump algorithms on both starting and stopping that minimize the pressure surges that cause water hammer. The pump control option will maximize the life of the pump and piping systems while minimizing the downtime caused by system failure.

Six SCRs control all three motor phases, providing smooth accelera-tion and deceleration performance.

Soft acceleration and deceleration reduces wear on belts, gears, chains, clutches, shafts and bearings.

Reduce the peak inrush current’s stress on the power system.

Minimize peak starting torque to diminish mechanical system wear and damage.

24V DC control module enhances personnel and equipment safety.

Removable, lockable control termi-nal block reduces maintenance costs. Also provides the opportunity for OEMs to reduce assembly and test costs by utilizing pre-assembled wire harnesses.

Protective Features

All protective features can be config-ured, enabled or disabled with the DIM or through the communications network.

Motor Overload

The S811 includes electronic overload protection as standard. The overload meets applicable requirements for a motor overload protective device. The overload protects the motor from over heat conditions with the use of sophisti-cated algorithms that model true motor heating, resulting in superior motor protection and fewer nuisance trips.

The S811 calculates a thermal memory value. A 100% value represents the maximum safe temperature of the motor. When the thermal memory value reaches 100%, an overload trip will occur removing power to the motor. Upon trip, the S811 stores the calculated motor heating value and will not allow a motor re-start until the motor has sufficiently cooled. This fea-ture ensures the motor will not be damaged by repeated overload trip, reset and re-start cycles.

The thermal memory value can be monitored through the DIM or the communications network. The thermal memory value can be of great use in determining an impending overload trip condition. Alarms can be imple-mented in the process monitoring system warning of an impending trip before a trip occurs halting the pro-cess. Costly system downtime can be avoided.

The trip current is adjusted to match the specific application requirements by entering the motor nameplate full load current rating and trip class. The FLA adjustment includes a 3 to 1 adjustment range. The overload trip class is adjustable from class 5 through class 30. The overload is ambient temperature compensated — meaning its trip characteristics will not vary with changes in ambient temperature. The overload protection can be enabled, disabled, or disabled on start.

Short Circuit

The use of a short circuit protective device in coordination with the S811 is required in branch motor circuits by most electrical codes. Short circuit coordination ratings with both fuses and Cutler-Hammer molded case cir-cuit breakers are available providing customers with design flexibility. The S811 has short circuit coordination ratings as an open component, an enclosed starter, and in a motor control center.

Jam

Excessive current and torque up to locked rotor levels can occur in a jam condition. The condition can result in stress and damage to the motor, load, mechanical system, and the electrical distribution system. Jam protection prevents the stress and damage from a jam during normal run. After the motor is started, a current greater than 300% FLA setting will cause the starter to trip on a jam fault.

Page 5: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit:

www.eaton.com

5Reduced Voltage Motor StartersSolid-State Starters

Type S811, Intelligent Technologies

(IT.)

Soft Starters with DIM

Stall

Excessive current and torque up to locked rotor levels can occur in a stall condition. The condition can lead to an overload trip and result in stress and damage to the motor, load, mechani-cal system, and the electrical distribu-tion system. Stall protection prevents stress and damage to a motor that has not come up to speed, or stalled after the soft start time. The S811 will trip to protect the system in the event that the motor did not get to the rated speed in the defined soft start period. A current greater than 200% FLA at the end of the soft start period will cause the starter to trip on a stall fault.

Pole Over Temperature

High ambient temperatures, extended ramp times and high duty cycle condi-tions may cause the S811 power pole conductors to reach a temperature that exceeds their thermal rating. The S811 is equipped with sensors that monitor the temperature of the power poles. Over temperature protection occurs if the device’s thermal capacity is exceeded. The soft starter will trip in over temperature conditions, prevent-ing device failure.

The device pole temperature value can be monitored through the DIM or the communications network. This feature can be of use in determining an impending over temperature trip condition. Alarms can be implemented in the process monitoring system warning of an impending trip before a trip occurs, halting the process. Costly system shutdown can be avoided.

Phase Loss

Loss of a phase can cause a significant increase in the current drawn in the remaining two phases. Phase loss can lead to motor damage before an even-tual overload trip occurs. Phase loss is typically an indication of a failure in the electrical distribution system. The S811 will detect a phase loss and trip if any phase current drops below a preset value. The phase loss trip level is adjustable from 0% to 100% of the average of the other two phase levels with an adjustable trip delay of 0.1 to 60 seconds.

Phase Imbalance

Phase current or voltage imbalance can cause a significant increase in the current drawn in the remaining two phases. Phase imbalance can lead to motor damage before an eventual overload trip. Phase imbalance is typically an indication of a failure in the electrical distribution system or the motor. The S811 will detect both current and voltage phase imbalances and trip if any phase becomes imbal-anced as compared to the average of the other two phases.

The phase current imbalance trip level is adjustable from 0% to 100% of the average of the current in the other two phases with an adjustable trip delay of 0.1 to 60 seconds.

The phase voltage imbalance trip level is adjustable from 0% to 100% of the average of the voltage in the other two phases with an adjustable trip delay of 0.1 to 60 seconds.

Reset Mode

The S811 can be set up for automatic or manual reset on trip. The manual reset mode requires the operator to physically press the RESET button located on the soft starter. The over-load can be manually reset through the DIM or through the communica-tions network. The overload can also be electrically reset by energizing a 24V DC input on the control terminal block.

The automatic reset mode allows the soft starter to be automatically reset as soon as the trip condition is no longer present. With the automatic reset mode, after the fault is no longer present, the motor will be restarted as soon as a valid start signal is present.

Phase Reversal

The S811 can determine if the proper line phase sequence is present by default. The device will trip if the line phase sequence is something other than A-B-C. The S811 can be config-ured to operate under reversed phase conditions (A-C-B).

Shorted SCR Detection

The S811 monitors the operation of the power poles and will trip under a shorted SCR condition.

Open SCR Detection

The S811 monitors the operation of the power poles and will trip under an open SCR condition.

Low Current

Low current conditions can be a result of a loss of load or a failure in the mechanical system. The S811 has low current protection that will trip if the average RMS current falls below a pre-set value. The low current protection can be programmed as a percent of motor FLA from 0% to 100%.

Low Voltage

Low voltage conditions can result from disturbances in the electrical power distribution system. Low voltage conditions can cause a malfunction and damage to electrical equipment. The S811 has low voltage protection that will trip if the average RMS volt-age falls below a preset value. The low voltage protection can be pro-grammed as a percent of nominal voltage from 1% to 99% with a trip delay of 0.1 to 60 seconds.

High Voltage

High voltage conditions can result from disturbances in the electrical power distribution system. High volt-age conditions can cause malfunctions or failures of electrical equipment. The S811 has high voltage protection that will trip if the average RMS voltage is greater than a preset value. The high voltage protection can be pro-grammed as a percent of nominal voltage from 101% to 120% with a trip delay of 0.1 to 60 seconds.

Page 6: Contents Reduced Voltage Motor Starters

April 2007

6

For more information visit:

www.eaton.com

CA03902004E

Reduced Voltage Motor StartersSolid-State Starters

Type S811, Intelligent Technologies

(IT.)

Soft Starters with DIM

Monitoring Capabilities

The S811 has an impressive array of system monitoring capabilities that allow users to access real time process and diagnostic data. This data can be viewed at the device with the DIM or through a communications network. Data over a communications network can provide valuable insight into the condition of the equipment and pro-cesses. Maintenance and production personnel can monitor critical opera-tional and maintenance data from a central control station that can be located far away from the production facility. Process data can be monitored to determine system anomalies that may indicate a need for preventive maintenance or an impeding failure. Adjustments made through the com-munications network can reduce costs by minimizing the time traveling to the location where the motor controls are located. When faults do occur, real time fault data can assist maintenance in troubleshooting and planning repair resources. Remote reset signals can be given to tripped devices without the need for manual intervention by main-tenance personnel.

Average Line Current

Provides the average of the three-phase RMS line currents in amps, accurate to within 2%. Current data can be used to indicate a need for maintenance. Increased currents in a fixed load application can indicate a reduction in system efficiencies and performance, signifying system maintenance is due.

Average Pole Current

Provides the average of the three-phase RMS pole currents in amps, accurate to within 2%. The pole current is the current through the soft starter. The line and pole current will be identical in in-line applications, and will differ in inside-the-delta applications.

Average line current as a % FLA

Provides the average RMS line current as a percentage of the S811 FLA setting.

Three-Phase Line CurrentsProvides three RMS phase line cur-rents in amps, accurate to within 2%. Imbalances or changes in the relative phase current to one another can indi-cate anomalies in the motor or electri-cal distribution system.

Three-Phase Pole CurrentsProvides three RMS phase pole cur-rents in amps, accurate to within 2%. The pole current is the current through the soft starter. The line and pole current will be identical in in-line applications, and will differ in inside-the-delta applications.

Three-Phase Line VoltagesProvides the individual RMS three-phase line voltages. Imbalances or changes in the relative phase voltage to one another can indicate anomalies in the motor or electrical distribution system. Voltage can be used to moni-tor electrical distribution system per-formance. Warnings, alarms and system actions to low or high voltage conditions can be implemented.

Percent Thermal MemoryProvides the real time calculated ther-mal memory value. The S811 calcu-lates thermal memory value. A 100% value represents the maximum safe temperature of the motor. When the thermal memory value reaches 100%, an overload trip will occur, removing power to the motor.

The thermal memory value can be of great use in determining an impending overload trip condition. Alarms can be implemented in the process monitor-ing system warning of an impending trip before a trip occurs, halting the process. Costly system downtime can be avoided.

DC Control VoltageMonitors level of the 24V DC control voltage. Fluctuations in control voltage can cause component malfunction and failure. System control voltage data can be used to implement warnings, alarms and system actions to low or high voltage conditions.

Pole TemperatureIncreases in pole temperature are caused by increases in ambient tem-perature, start/stop times and start duty cycles. Changes in pole tempera-tures represent a change in system operating conditions. Identifying unexpected operating conditions or changes can prompt maintenance and aid in process evaluation activities.

Device TemperatureAn increase in device temperature is a strong indication of an increase in ambient temperature. High ambient temperature operation can be identi-fied with the Device Temperature data. Ambient temperature increases can be due to loss of enclosure cooling fans or blocked venting. High ambient temperatures will reduce the life of all electrical equipment in the enclosure.

Start CountStart count data can be used to monitor system output, schedule preventative maintenance, identify system anomalies and identify changes in system operation.

Diagnostics

Fault QueueCurrent fault and a fault queue con-taining the last nine system faults can be read through the DIM or communi-cations network. Fault identification can minimize troubleshooting time and cost and prevent arc flash inci-dents. The fault queue can be remotely accessed through a communications network to assist in planning mainte-nance resources. 30 different faults can be identified by the S811.

Control StatusThe S811 provides data that repre-sents system conditions that can be read through the DIM or the communi-cations network. This data identifies the status of the system and the con-trol commands the system is request-ing of the S811. This can be used for advanced troubleshooting and system integration activities.

Breaker StatusThe S811 has provisions to read and display circuit breaker status. Cutler-Hammer communicating Cover Con-trol or other communicating protective device is required to take advantage of this feature.

Page 7: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

7Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Operation

Starting and Stopping ModesThe S811 has a variety of starting and stopping methods to provide superior performance in the most demanding applications. The motor can be started in either Voltage Ramp Start or Current Limit Start mode. Kick Start and Soft Stop are available within both starting modes.

Voltage Ramp StartProvides a voltage ramp to the motor resulting in a constant torque increase. The most commonly used form of soft start, this start mode allows you to set the initial torque value and the duration of the ramp to full voltage conditions. Bypass contactors close after ramp time.

■ Adjustable initial torque 0 – 85% of locked rotor torque.

■ Adjustable ramp time 0.5 – 180 seconds (can be extended with factory modification).

Current Limit StartLimits the maximum current available to the motor during the start phase. This mode of soft starting is used when it becomes necessary to limit the maxi-mum starting current due to long start times or to protect the motor. This start mode allows you to set the maximum starting current as a percentage of locked rotor current and the duration of the current limit. Bypass contactors close after current limit time.

■ Maximum current of 0 – 85% locked rotor current.

■ Adjustable ramp time 0.5 – 180 seconds (can be extended with factory modification).

Kick StartSelectable feature in both Voltage Ramp Start and Current Limit Start modes. Provides a current and torque “kick” for 0 to 2.0 seconds. This pro-vides greater initial current to develop additional torque to breakaway a high friction load.

■ 0 – 85% of locked rotor torque■ 0 – 2.0 seconds duration

Soft StopAllows for a controlled stopping of a load. Used when a stop-time that is greater than the coast-to-stop time is desired. Often used with high friction loads where a sudden stop may cause system or load damage.

■ Stop time = 0 – 60 seconds.

Figure 3. Starting Characteristics — Ramp Start

Figure 4. Starting Characteristics — Current Limit Start

Figure 5. Starting Characteristics — Kick Start

Figure 6. Starting Characteristics — Soft Stop

Run (FLA)

100%

Lock

ed R

oto

r To

rqu

e

Time (Seconds)

InitialTorque

Run

Max.Allowed

100%FLA

Cu

rren

t

Time (Seconds)

100%

Lock

ed R

oto

r To

rqu

e

Ramp

Time (Seconds)

KickStart

Run (FLA)

Ramp

Time (Seconds)

Run

Page 8: Contents Reduced Voltage Motor Starters

April 2007

8

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Catalog Number Selection Table 2. S811 Open Soft Starters Catalog Numbering System

� Not available in U-Frame.� U-Frame 500 Amp unit does not have IEC Certification.

Edge and Level Sensing Control

Edge SensingEdge sensing is denoted with an “S” in the last character of the Catalog Number. Example: S801T30N3S.

Edge sensing requires +24V DC power be momentarily applied to pin 1 (with terminal P at +24V DC) to initiate a start under all conditions. After a stop or fault occurs, the +24V DC must be removed, then reapplied to pin 1 before another start can occur. This control configuration should be used when restarting of the motor after a fault or stop must be supervised man-ually or as a part of a control scheme. The cycling of +24V DC power to ter-minal 1 before starting is required regardless of the position of the auto reset switch on the CIM.

Level Sensing Level sensing is denoted with a “B” in the last character of the Catalog Number. Example: S801T30N3B.

Level sensing will enable a motor to restart after a fault is cleared without cycling +24V DC power to terminal 1 as long as:

■ Terminal P is supplied with +24V DC (to start from Terminal Block, Input #3 must also be enabled),

■ The auto reset switch on the CIM is set to enabled,

■ All faults have been reset.

This control configuration should be used where it is desirable to restart a motor after a fault without additional manual or automatic control. An example of this condition would be on a remote pumping station where it is desirable to automatically restart a pump after a power outage without operator intervention.

If the auto reset feature is used, CAUTION must be exercised to assure that any restart occurs in a safe manner.

S 8 1 1 T 3 0 N 3 S

Ampacity Rating

37 = 37 amps66 = 66 amps10 = 105 amps13 = 135 amps18 = 180 amps24 = 240 amps30 = 304 amps

36 = 360 amps42 = 420 amps50 = 500 amps �65 = 650 amps72 = 720 amps85 = 850 amps10 = 1000 amps

Frame Size

N = 65 mmR = 110 mmT = 200 mmU = 200 mmV = 290 mm

811 = Non-combination Soft Starter

N = No OptionsP = Pump ControlV = 690V Option

(Frame T18 through V85) �

3 = 3-Pole Device

S = Standard Soft Starter (Configurable for Edge or Level Control)

D = Inside-the-DeltaL = Extended Ramp StartW = Without DIM

S = IT. Soft Starter

Page 9: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

9Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Product Selection Motor applications and customer needs come in many different varieties. With the standard and severe duty rating tables, we have attempted to provide guidelines on what the IT. Soft Starter is capable of. If the application falls

under these categories, you can use these charts. For other applications, or when a question arises, consult with your local Eaton Representative or call our Technical Resource Center.

Standard DutyTable 3. Standard Duty Ratings

Table 4. Product Selection — 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C

� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.� 500A rating does not have IEC certification.

Starting Method Ramp Current %of FLA

Ramp TimeSeconds

Starts perHour

AmbientTemperature

vs. Soft Startvs. Full Voltagevs. Wye-Deltavs. 80% RVATvs. 65% RVATvs. 50% RVAT

300%500%350%480%390%300%

30 sec.10 sec.20 sec.20 sec.20 sec.20 sec.

333234

50°C50°C50°C50°C50°C50°C

Max.Current

Three-Phase Motors CatalogNumber

PriceU.S. $

kW Rating (50 Hz) hp Rating (60 Hz)

230V 380 – 400V

440V 200V 230V 460V 575 – 690V

1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N

3766

1018.5

18.530

18.537

1020

1015

1020

1020

2550

2040

3060

3050

S811N37N3SS811N66N3S

1,960.3,010.

Frame Size R

105135

3040

5563

5980

3040

2530

4050

3040

75100

6075

100125

75100

S811R10N3SS811R13N3S

4,540.5,640.

Frame Size T

180240304

517590

90110160

110147185

6075

100

506075

6075

100

6075

100

150200250

125150200

150200300

150200250

S811T18N3SS811T24N3SS811T30N3S

5,780.6,150.6,540.

Frame Size U

360420500

110129150

185220257

220257300

125150150

100125150

150175200

125150150

300350400

250300350

350450500

300350450

S811U36N3SS811U42N3SS811U50N3S �

7,880.8,870.9,980.

Frame Size V

360420500650

110129150200

185220257355

220257300425

125150150250

100125150200

150175200250

125150150200

300350400500

250300350450

350450500600

300350450500

S811V36N3SS811V42N3SS811V50N3SS811V65N3S

7,610.8,570.9,640.

10,850.

720850

1000

220257277

400475525

45050050

———

———

300350400

250300350

600700800

500600700

700900900

600700800

S811V72N3SS811V85N3SS811V10N3S �

12,470.15,100.25,200.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 10: Contents Reduced Voltage Motor Starters

April 2007

10

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Table 5. Product Selection — 25 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C

� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.� 500A rating does not have IEC certification.

Table 6. Product Selection — 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 50°C

� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.� 500A rating does not have IEC certification.

Max.Current

Three-Phase Motors CatalogNumber

PriceU.S. $

kW Rating (50 Hz) hp Rating (60 Hz)

230V 380 – 400V

440V 200V 230V 460V 575 – 690V

1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N

3463

915

1530

18.533

1020

7-1/215

1020

1020

2540

2040

3060

2550

S811N37N3SS811N66N3S

1,960.3,010.

Frame Size R

96120

2533

4563

5563

3040

2530

3040

3040

7575

6075

75100

75100

S811R10N3SS811R13N3S

4,540.5,640.

Frame Size T

150215278

456380

80110147

90132160

506075

406075

5075

100

506075

100150200

100150200

150200250

125150250

S811T18N3SS811T24N3SS811T30N3S

5,780.6,150.6,540.

Frame Size U

320380460

90110140

160200250

185220280

100125150

75100125

125150150

100125150

250300350

200250300

300350450

250300400

S811U36N3SS811U42N3SS811U50N3S �

7,880.8,870.9,980.

Frame Size V

320380460610

90110140185

160200250315

185220280375

100125150250

75100125150

125150150200

100125150200

250300350500

200250300450

300350450600

250300400500

S811V36N3SS811V42N3SS811V50N3SS811V65N3S

7,610.8,570.9,640.

10,850.

680810890

200250290

375450510

445500560

———

200——

250300400

200300350

600700700

500600600

700900900

600700700

S811V72N3SS811V85N3SS811V10N3S �

12,470.15,100.25,200.

Max.Current

Three-Phase Motors CatalogNumber

PriceU.S. $

kW Rating (50 Hz) hp Rating (60 Hz)

230V 380 – 400V

440V 200V 230V 460V 575 – 690V

1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N

3463

915

1530

18.533

1020

7-1/215

1020

1020

2540

2040

3060

2550

S811N37N3SS811N66N3S

1,960.3,010.

Frame Size R

96120

2533

4563

5563

3040

2530

3040

3040

7575

6075

75100

75100

S811R10N3SS811R13N3S

4,540.5,640.

Frame Size T

150215278

456380

80110147

90132160

506075

406075

5075

100

506075

100150200

100150200

150200250

125150250

S811T18N3SS811T24N3SS811T30N3S

5,780.6,150.6,540.

Frame Size U

320380460

90110140

160200250

185220280

100125150

75100125

125150150

100125150

250300350

200250300

300350450

250300400

S811U36N3SS811U42N3SS811U50N3S �

7,880.8,870.9,980.

Frame Size V

320380460610

90110140185

160200250315

185220280375

100125150250

75100125150

125150150200

100125150200

250300350500

200250300450

300350450600

250300400500

S811V36N3SS811V42N3SS811V50N3SS811V65N3S

7,610.8,570.9,640.

10,850.

680830960

200257302

375450510

445500540

———

200——

250300350

200300300

600700800

500600700

700900900

600700800

S811V72N3SS811V85N3SS811V10N3S �

12,470.15,100.25,200.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 11: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

11Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Table 7. Product Selection — 50 Second Ramp, 2 Starts per Hour, 300% Current Limit @ 50°C

� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.� 500A rating does not have IEC certification.

Table 8. Product Selection — 15 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C

� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.

Max.Current

Three-Phase Motors CatalogNumber

PriceU.S. $

kW Rating (50 Hz) hp Rating (60 Hz)

230V 380 – 400V

440V 200V 230V 460V 575 – 690V

1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N

2142

5.511

1018.5

1122

510

510

515

510

1530

1025

1540

1530

S811N37N3SS811N66N3S

1,960.3,010.

Frame Size R

6080

1522

3040

3345

1525

1520

2030

1525

4060

4050

5075

5060

S811R10N3SS811R13N3S

4,540.5,640.

Frame Size T

115150192

334555

5980

100

6390

110

305060

304050

405060

305060

75100150

75100125

100150200

100125150

S811T18N3SS811T24N3SS811T30N3S

5,780.6,150.6,540.

Frame Size U

280340380

80110110

150180200

160200220

75100125

75100100

100125150

75100125

200250300

200200250

250350350

250300300

S811U36N3SS811U42N3SS811U50N3S �

7,880.8,870.9,980.

Frame Size V

280340380420

80110110129

150180200220

160200220257

75100125150

75100100125

100125150150

75100125150

200250300350

200200250300

250350350450

250300300350

S811V36N3SS811V42N3SS811V50N3SS811V65N3S

7,610.8,570.9,640.

10,850.

480590650

147180205

257315370

295375415

150200250

150150200

200200250

150200200

400500500

350400450

500600600

450500500

S811V72N3SS811V85N3SS811V10N3S �

12,470.15,100.25,200.

Max.Current

Three-Phase Motors CatalogNumber

PriceU.S. $

kW Rating (50 Hz) hp Rating (60 Hz)

230V 380 – 400V

440V 200V 230V 460V 575 – 690V

1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N

2949

7.512.5

12.522

1525

7-1/215

7-1/210

1015

7-1/215

2030

1530

2540

2040

S811N37N3SS811N66N3S

1,960.3,010.

Frame Size R

7394

18.525

3745

4055

2030

2025

2530

2030

5060

4060

6075

6075

S811R10N3SS811R13N3S

4,540.5,640.

Frame Size T

155219280

456380

80110150

90132160

506075

406075

6075

100

506075

100150200

100150200

150200250

125150250

S811T18N3SS811T24N3SS811T30N3S

5,780.6,150.6,540.

Frame Size U

345405

100110

185200

200250

100125

100100

125150

100125

250300

200250

350400

300350

S811U36N3SS811U42N3S

7,880.8,870.

Frame Size V

345405465530

100110140160

185200250280

200250280335

100125150150

100100125150

125150150200

100125150150

250300350450

200250300350

350400450500

300350400450

S811V36N3SS811V42N3SS811V50N3SS811V65N3S

7,610.8,570.9,640.

10,850.

590651754

180200220

315355400

375425465

200——

150——

———

200——

500600600

400450500

600700800

500600700

S811V72N3SS811V85N3SS811V10N3S �

12,470.15,100.25,200.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 12: Contents Reduced Voltage Motor Starters

April 2007

12

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Table 9. Product Selection — 30 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C

� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.

Max.Current

Three-Phase Motors CatalogNumber

PriceU.S. $

kW Rating (50 Hz) hp Rating (60 Hz)

230V 380 – 400V

440V 200V 230V 460V 575 – 690V

1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N

2140

5.511

1018.5

12.522

510

510

510

510

1530

1025

1530

1530

S811N37N3SS811N66N3S

1,960.3,010.

Frame Size R

5575

1522

2537

3045

1520

1520

2025

1520

4050

3050

5060

4060

S811R10N3SS811R13N3S

4,540.5,640.

Frame Size T

151215264

456380

80110140

90132160

506075

406075

5075

100

506075

100150200

100150150

150200250

125150200

S811T18N3SS811T24N3SS811T30N3S

5,780.6,150.6,540.

Frame Size U

300340

90100

160180

185200

100100

75100

100125

100100

200250

200200

300350

250300

S811U36N3SS811U42N3S

7,880.8,870.

Frame Size V

300340380420

90100110129

160180200220

185200220257

100100125150

75100100125

100125150150

100100125150

200250300350

200200250300

300350350450

250300300350

S811V36N3SS811V42N3SS811V50N3SS811V65N3S

7,610.8,570.9,640.

10,850.

460500560

140150160

250257277

280300325

150150200

125150150

150200250

150150200

350400500

300350400

450500600

400450500

S811V72N3SS811V85N3SS811V10N3S �

12,470.15,100.25,200.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 13: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

13Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Severe DutyTable 10. Severe Duty Ratings

Table 11. Product Selection — > 30 Second Ramp, > 4 Starts per Hour or >300% Current Limit

� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.

Severe Duty Ratings are defined as any combination of parameters that exceed the Standard Duty Ratings where the ramp time is over 30 seconds, the number of starts per hour exceeds 4, or the current limit set is over 300%. Example: 35-Second Ramp, 5 Starts per Hour, 350% Current Limit @ 40°C Ambient.

Starting Method Ramp Current %of FLA

Ramp TimeSeconds

Starts perHour

Ambient Temperature

vs. Soft Startvs. Full Voltagevs. Wye-Deltavs. 80% RVATvs. 65% RVATvs. 50% RVAT

450%500%350%480%390%300%

30 sec.10 sec.65 sec.25 sec.40 sec.60 sec.

4103444

50°C50°C50°C50°C50°C50°C

Max.Current

Three-Phase Motors CatalogNumber

PriceU.S. $

kW Rating (50 Hz) hp Rating (60 Hz)

230V 380 – 400V

440V 200V 230V 460V 575 – 690V

1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N

2242

5.511

1018.5

1122

510

510

7-1/215

510

1530

1025

2040

1530

S811N37N3SS811N66N3S

1,960.3,010.

Frame Size R

6580

1522

3040

3345

1525

1520

2030

1525

5060

4050

5075

5060

S811R10N3SS811R13N3S

4,540.5,640.

Frame Size T

115150192

334555

5980

100

6390

110

305060

304050

405075

305060

75100150

75100125

100150200

100125150

S811T18N3SS811T24N3SS811T30N3S

5,780.6,150.6,540.

Frame Size U

240305

7590

110160

147185

75100

6075

75100

75100

200250

150200

200300

200250

S811U36N3SS811U42N3S

7,880.8,870.

Frame Size V

240305365420

7590

110129

110160185220

147185220257

75100125150

6075

100125

75100150150

75100125150

200250300350

150200250300

200300350450

200250300350

S811V36N3SS811V42N3SS811V50N3SS811V65N3S

7,610.8,570.9,640.

10,850.

480525575

147160172

257280303

295335370

150150200

150150150

200200250

150150200

400450500

350350450

500500600

450450500

S811V72N3SS811V85N3SS811V10N3S �

12,470.15,100.25,200.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 14: Contents Reduced Voltage Motor Starters

April 2007

14

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Inside-the-Delta Standard Duty Ratings

Table 12. 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C Ambient

� 15 sec. start, 300% inrush, 40°C, 1 start every 15 minutes. If these start parameters are exceeded, please refer to 290 mm V-Frame, 865A Inside-the-Delta Starter.

� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.

Table 13. 25 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C Ambient

� 15 sec. start, 300% inrush, 40°C, 1 start every 15 minutes. If these start parameters are exceeded, please refer to 290 mm V-Frame, 796A Inside-the-Delta Starter.

� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.

Max.Continuous Motor Line Current

Three-Phase Motor CatalogNumber

PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)

230 380 – 400 440 200V 230V 460V 575V

Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N65

1141018.5

18.530

18.537

1530

1525

1530

1530

4075

3060

50100

5075

S811N37N3DS811N66N3D

1,960.3,010.

Frame Size R182234

3040

5563

5980

5060

4050

6075

5060

125150

100125

150200

125150

S811R10N3DS811R13N3D

4,540.5,640.

Frame Size T311415526

517590

90110160

110147185

100125150

75100125

100125150

100125150

250300400

200250300

250300400

250300400

S811T18N3DS811T24N3DS811T30N3D

5,780.6,150.6,540.

Frame Size U623727865

110129150

185220257

220257300

200250250

150200250

250300300

200250250

450550600

400450550

550700750

450550700

S811U36N3DS811U42N3DS811U50N3D ��

7,880.8,870.9,980.

Frame Size V623727865

112512461471—

110129150200———

185220257355———

220257300425———

200250250400———

150200250300———

250300300400———

200250250300———

450550600750———

400450550700———

550700750900———

450550700750———

S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �

7,610.8,570.9,640.

10,850.12,470.15,100.25,200.

Max.Continuous Motor Line Current

Three-Phase Motor CatalogNumber

PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)

230 380 – 400 440 200V 230V 460V 575V

Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N58

1089

151530

18.533

1530

1025

1530

1530

4060

3060

50100

4075

S811N37N3DS811N66N3D

1,960.3,010.

Frame Size R164206

2533

4563

5563

5060

4050

5060

5050

125125

100125

125150

125150

S811R10N3DS811R13N3D

4,540.5,640.

Frame Size T257365477

456380

80110147

90132160

75100125

60100125

75125150

60100125

150250300

150250300

250300400

200250400

S811T18N3DS811T24N3DS811T30N3D

5,780.6,150.6,540.

Frame Size U554646796

90110140

160200250

185220280

150200250

125150200

200250250

150200250

400500550

300400500

450550700

400450600

S811U36N3DS811U42N3DS811U50N3D ��

7,880.8,870.9,980.

Frame Size V554646796

105511761358—

90110140185200——

160200250315375——

185220280375445——

150200250400———

125150200250300——

200250250300400——

150200250300300——

400500550800900——

300400500700800——

450550700900900——

400450600750900——

S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �

7,610.8,570.9,640.

10,850.12,470.15,100.25,200.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 15: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

15Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Inside-the-Delta Standard Duty Ratings

Table 14. 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 50°C Ambient

� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.

Table 15. 50 Second Ramp, 2 Starts per Hour, 300% Current Limit @ 50°C Ambient

� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.

Max.Continuous Motor Line Current

Three-Phase Motor CatalogNumber

PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)

230 380 – 400 440 200V 230V 460V 575V

Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N58

1089

151530

18.533

1530

1025

1530

1530

4060

3060

50100

4075

S811N37N3DS811N66N3D

1,960.3,010.

Frame Size R164206

2533

4563

5563

5060

4050

5060

5060

125125

100125

125150

125150

S811R10N3DS811R13N3D

4,540.5,640.

Frame Size T257365477

456380

80110147

90132160

75100125

60100125

75125150

75100125

150250300

150250300

250300400

200250400

S811T18N3DS811T24N3DS811T30N3D

5,780.6,150.6,540.

Frame Size U554646796

90110140

160200250

185220280

150200250

125150200

200250250

150200250

400450550

300400450

450550700

400450600

S811U36N3DS811U42N3DS811U50N3D �

7,880.8,870.9,980.

Frame Size V554646796

105511761358—

90110140185200257—

160200250315375450—

185220280375445500—

150200250400———

125150200250———

200250250300———

150200250300———

400450550750———

300400450700———

450550700900———

400450600750———

S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �

7,610.8,570.9,640.

10,850.12,470.15,100.25,200.

Max.Continuous Motor Line Current

Three-Phase Motor CatalogNumber

PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)

230 380 – 400 440 200V 230V 460V 575V

Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N3673

5.511

1018.5

1122

7-1/215

7-1/215

7-1/225

7-1/215

2550

1540

2560

2550

S811N37N3DS811N66N3D

1,960.3,010.

Frame Size R103138

1522

3040

3345

2540

2530

3050

2540

60100

6075

75125

75100

S811R10N3DS811R13N3D

4,540.5,640.

Frame Size T199257324

334555

5980

100

6390

110

5075

100

506075

6075

100

5075

100

125150250

125150200

150250300

150200250

S811T18N3DS811T24N3DS811T30N3D

5,780.6,150.6,540.

Frame Size U485580646

80100110

150180200

160200220

125150200

125150150

150200250

125150200

300400450

300300400

400550550

400450450

S811U36N3DS811U42N3DS811U50N3D �

7,880.8,870.9,980.

Frame Size V485580646727816

1021—

80100110129147180—

150180200220257315—

160200220257295375—

125150200250250300—

125150150200250250—

150200250250300300—

125150200250250300—

300400450550600750—

300300400500550600—

400550550700750900—

400450450550700750—

S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �

7,610.8,570.9,640.

10,850.12,470.15,100.25,200.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 16: Contents Reduced Voltage Motor Starters

April 2007

16

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Inside-the-Delta Standard Duty Ratings

Table 16. 15 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C Ambient

� U-Frame 500 Amp unit does not have IEC Certification.

Table 17. 30 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C Ambient

� U-Frame 500 Amp unit does not have IEC Certification.

Max.Continuous Motor Line Current

Three-Phase Motor CatalogNumber

PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)

230 380 – 400 440 200V 230V 460V 575V

Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N4783

7.512.5

12.522

1525

1025

1015

1525

1025

3050

2550

4060

3060

S811N37N3DS811N66N3D

1,960.3,010.

Frame Size R126162

18.525

3745

4055

3050

3040

4050

3050

75100

60100

100125

100125

S811R10N3DS811R13N3D

4,540.5,640.

Frame Size T266379485

456380

80110150

90132160

75100125

60100125

100125150

75100125

150250300

150250300

250300400

200250400

S811T18N3DS811T24N3DS811T30N3D

5,780.6,150.6,540.

Frame Size U580695798

100110140

185200250

200250280

150200250

150150200

200250250

150200250

400450550

300400450

550600700

450550600

S811U36N3DS811U42N3DS811U50N3D �

7,880.8,870.9,980.

Frame Size V580695798908

10211125

100110140160——

185200250280——

200250280335——

150200250250——

150150200250——

200250250300——

150200250250——

400450550700——

300400450550——

550600700750——

450550600700——

S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3D

7,610.8,570.9,640.

10,850.12,470.15,100.

Max.Continuous Motor Line Current

Three-Phase Motor CatalogNumber

PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)

230 380 – 400 440 200V 230V 460V 575V

Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N3669

5.511

1018.5

12.522

7-1/215

7-1/215

7-1/215

7-1/215

2550

1540

2550

2550

S811N37N3DS811N66N3D

1,960.3,010.

Frame Size R96

1301522

2537

3045

2530

2530

3040

2530

6075

5075

75100

60100

S811R10N3DS811R13N3D

4,540.5,640.

Frame Size T257365448

456380

80110140

90132160

75100125

60100125

75125150

75100125

150250300

150250250

250300400

200250300

S811T18N3DS811T24N3DS811T30N3D

5,780.6,150.6,540.

Frame Size U503580646

90100110

160180200

185200220

150150200

125150150

150200250

150150200

300400450

300300400

450550550

400450450

S811U36N3DS811U42N3DS811U50N3D �

7,880.8,870.9,980.

Frame Size V503580646727796865

90100110129——

160180200220——

185200220257——

150150200250——

125150150200——

150200250250——

150150200250——

300400450550——

300300400450——

450550550700——

400450450550——

S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3D

7,610.8,570.9,640.

10,850.12,470.15,100.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 17: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

17Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Inside-the-Delta Severe Duty Ratings Severe Duty Ratings are defined as any combination of parameters that exceed the Standard Duty Ratings where the ramp time is over 30 seconds, the num-ber of starts per hour exceeds 4, or the current limit set is over 300%.

Example: 35-Second Ramp, 5 Starts per Hour 350% Current Limit @ 40°C Ambient.

Table 18. Severe Duty Inside-the-Delta Ratings

� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.

Typical Power Wiring Diagrams

Figure 7. Line Connected Soft Starter Power Wiring Diagram

Max.Continuous Motor Line Current

Three-Phase Motor CatalogNumber

PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)

230 380 – 400 440 200V 230V 460V 575V

Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF

Frame Size N3973

5.511

1018.5

1122

7-1/215

7-1/215

1025

7-1/215

2550

1540

3060

2550

S811N37N3DS811N66N3D

1,960.3,010.

Frame Size R111138

1522

3040

3345

2540

2530

3050

2540

75100

6075

75120

75100

S811R10N3DS811R13N3D

4,540.5,640.

Frame Size T199257324

334555

5980

100

6390

110

5075

100

506075

6075

100

5075

100

125150250

125150200

150250300

150200250

S811T18N3DS811T24N3DS811T30N3D

5,780.6,150.6,540.

Frame Size U415526623

7590

110

110160185

147185220

125150200

100120150

125150250

125150200

300400450

250300400

300450550

300400450

S811U36N3DS811U42N3DS811U50N3D �

7,880.8,870.9,980.

Frame Size V415526623727816908—

7590

110129147160—

110160185220257280—

147185220257295335—

125150200250250250—

100120150200250250—

125150250250300300—

125150200250250250—

300400450550600700—

250300400450550550—

300450550700750750—

300400450550700700—

S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �

7,610.8,570.9,640.

10,850.12,470.15,100.25,200.

1 L1 3 L2

S811

5 L3

2 T1 4 T2 6 T3

M3˜

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 18: Contents Reduced Voltage Motor Starters

April 2007

18

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Figure 8. Inside-the-Delta Connected Soft Starter Power Wiring Diagram for a6-Lead Motor

Figure 9. Inside-the-Delta Connected Soft Starter Power Wiring Diagram for a12-Lead Low Voltage Motor

Figure 10. Inside-the-Delta Connected Soft Starter Power Wiring Diagram for a12-Lead High Voltage Motor

L1S L2SSupply

L3S

L31L1

3L2

5L3

T5 T4 T6

T3

T3

T3

T6

T4

T1T1

T2

T2

T2

T1

2T1

4T2

6T3

S811

T5

L1

L1

Motor

L3

L2L2

L1S L2SSupply

L3S

L3

L1

1L1

3L2

5L3

T11T5

T11T10T4

T12T6

T3T9

T3

T5

T3

T6T10

T7

T4

T1

T1

T12

T9

T2T8

T2T2

T1T7

2T1

4T2

6T3

T8

L1

Motor

L3

L2L2

12-LeadLow Voltage

S811

L1S L2SSupply 12-Lead

High VoltageL3S

L3

L1

1L1

3L2

5L3

T11

T11

T10 T12

T3

T3

T3

T6T10

T7T4

T1T1

T12

T9

T2

T2

T2

T1

2T1

4T2

6T3

T8T5

T5T8

T6T9

L1

T7T4

Motor

L3

L2L2

S811

Page 19: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

19Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Options Extended Ramp For a longer ramp acceleration time of .5 – 360 seconds, change the last digit in the Catalog Number from Page 9 to L. Table 19. Extended Ramp Option

� U-Frame 500 Amp unit does not have IEC Certification.

Extended Ramp and 690V Option690V ratings are available on the T and V Frames by changing the 8th digit in the Catalog Number to V.Table 20. 690V Option

Pump ControlFor pump control option, change the 8th digit in the Catalog Number to P.Table 21. Pump Control Option

� U-Frame 500 Amp unit does not have IEC Certification.

FrameSize

Max.Current

CatalogNumber

PriceU.S. $

N 3766

S811N37N3LS811N66N3L

2,360.3,415.

R 105135

S811R10N3LS811R13N3L

4,945.5,640.

T 180240304

S811T18N3LS811T24N3LS811T30N3L

6,190.6,570.6,940.

U 360420500

S811U36N3LS811U42N3LS811U50N3L �

8,320.9,290.

10,400.V 360

420500650

S811V36N3LS811V42N3LS811V50N3LS811V65N3L

8,030.8,970.

10,040.11,260.

720850

1000

S811V72N3LS811V85N3LS811V10N3L

12,870.15,490.24,710.

Frame Size

Max.Current

CatalogNumber

PriceU.S. $

T 180240304

S811T18V3LS811T24V3LS811T30V3L

6,930.7,310.7,450.

V 360420500

S811V36V3LS811V42V3LS811V50V3L

8,530.9,490.

10,560.650720850

S811V65V3LS811V72V3LS811V85V3L

11,770.13,380.16,010.

FrameSize

Max.Current

CatalogNumber

PriceU.S. $

N 3766

S811N37P3SS811N66P3S

3,170.4,230.

R 105135

S811R10P3SS811R13P3S

5,750.6,660.

T 180240304

S811T18P3SS811T24P3SS811T30P3S

7,010.7,360.7,740.

U 360420500

S811U36P3SS811U42P3SS811U50P3S �

9,160.10,150.11,250.

V 360420500650

S811V36P3SS811V42P3SS811V50P3SS811V65P3S

8,850.9,800.

10,860.12,090.

720850

1000

S811V72P3SS811V85P3SS811V10P3S

13,690.16,330.25,490.

Accessories

Surge SuppressorsThe surge suppressor can mount on either the line or load side of the IT. Soft Starter. It is designed to clip the line voltage (or load side induced voltage).

Table 22. Surge Suppressors

� T-Frame only.

Lug Kits The 200 mm and 290 mm soft starters do not include lugs.

The 200 mm and 290 mm soft starters each have different lug options based on your wiring needs. Each lug kit con-tains three lugs which can be mounted on either the load or line side.

Table 23. Lug Kits

� The EML33 does not have a CSA Listing.

Lug Cover Kits Replacement covers for the T and V frame are available in case of damage to the existing covers.

Table 24. Lug Cover Kits

Description CatalogNumber

PriceU.S. $

600V MOV for 65 mm and 110 mm units

EMS38 178.

600V MOV for 200 mm and 290 mm units

EMS39 193.

690V MOV for 200 mm � and 290 mm units

EMS41 220.

Surge Suppressor

Surge SuppressorMounted on a 200 mm Device

Lug Kits — EML23

FrameSize

FrameDesignation

Description CatalogNumber

PriceU.S. $

200 mm SSRV

T, U 2 cable connections, 4 AWG to 1/0 cable1 cable connection, 4/0 to 500 MCM cable2 cable connections, 4/0 to 500 MCM cable1 cable connection, 2/0 to 300 MCM cable2 cable connections, 2/0 to 300 MCM cable

EML22EML23EML24EML25EML26

175.197.249.175.222.

290 mmSSRV

V 2 cable connections, 4/0 to 500 MCM cable4 cable connections, 4/0 to 500 MCM cable6 cable connections, 4/0 to 500 MCM cable4 cable connections, 2/0 to 300 MCM cable

EML28EML30EML32EML33 �

402.403.585.408.

Description CatalogNumber

PriceU.S.$

Lug Cover T, U Frame EML27 79.

Lug Cover V Frame EML34 98.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 20: Contents Reduced Voltage Motor Starters

April 2007

20

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Digital Interface ModuleThe Digital Interface Module (DIM) is available as a replacement part.

Table 25. DIM

Control Wire ConnectorTable 26. Control Wire Connector

User Manual A comprehensive user manual is available and can be downloaded free of charge from www.eaton.com by performing a document search for MN03902002E.

Mounting PlatesThe Mounting Plates are designed to help make it easy to install or retrofit the soft starter into enclosures and MCCs. The soft starter can be mounted onto the plate prior to installation. The mounting plate is designed with tear drop mounting holes for easier installation.

Table 27. Mounting Plates

Adapter PlatesThe Adapter Plate allows customers to retrofit a V-Frame 290 mm Soft Starter with the U-Frame 200 mm Soft Starter.

Table 28. Adapter Plates

� For more information see Pub. 51719.

Vibration PlatesThe Vibration Plates allow the soft starter to be applied in high shock and vibration applications. The vibration plate allows vibration up to 5g and shock in up to 40g. The soft starter is mounted onto the vibration plate prior to installation in the panel.

Table 29. Vibration Plates

Power Supplies24V DC Power Supply which can be used with the S811 SSRV or as a stand- alone device.

Table 30. Power Supplies

DIN Rail Power Supply Mounting Kit (35 mm) Table 31. DIN Rail Mounting Kit

Standards and Certifications ■ IEC 60947-4-2■ EN 60947-4-2■ UL Listed (NMFT) – Frame N37

to V85■ UL Recognized (NMFT2) – Frame V10■ CE Marked■ CSA Certified (3211 06)■ CSA Elevator (2411 01)

Instructional Leaflets■ Instruction Manual: MN03902002E■ Outline Drawings:

❑ 65 mm, N-Frame: 10-8574❑ 110 mm, R-Frame: 10-8575❑ 200 mm, T-Frame: 10-8576❑ 200 mm, U-Frame: 10-8857❑ 290 mm, V-Frame: 10-8577

Description CatalogNumber

PriceU.S. $

Blank Cover (Filler) EMA68 58.50

DIM EMA91 332.00

Panel Mounting Kit —3 ft. Cable5 ft. Cable8 ft. Cable

10 ft. Cable

EMA69AEMA69BEMA69CEMA69D

196.00221.00245.00271.00

Description CatalogNumber

PriceU.S.$

12 pin, 5 mm pitchConnector forControl Wiring

EMA75L 16.20

Description CatalogNumber

PriceU.S. $

Mounting Plate N Frame EMM13N 61.50

Mounting Plate R Frame EMM13R 85.00

Mounting Plate T, U Frame

EMM13T 95.00

Mounting Plate V Frame EMM13V 122.00

Fan/Hood Accessory EMM18 158.00

Description CatalogNumber

PriceU.S. $

Adapter Plates � EMM13U 220.00

Description CatalogNumber

PriceU.S. $

Vibration Plate N Frame EMM14N 158.00

Vibration Plate R Frame EMM14R 170.00

Vibration Plate T, U Frame

EMM14T 196.00

Vibration Plate V Frame EMM14V 228.00

Description CatalogNumber

PriceU.S. $

115V AC Input24V DC Output

PSS55A 262.00

230V AC Input24V DC Output

PSS55B 262.00

380 – 480V AC Input24V DC Output

PSS55C 312.00

Description CatalogNumber

PriceU.S. $

DIN Rail Mounting Kit (35 mm)

PSSDIN 25.00

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

Page 21: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

21Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Technical Data and SpecificationsTable 32. Specifications— IT. Soft Starter

� U-Frame 500 Amp unit does not have IEC Certification.� UR Recognized Product.

Soft Starter (Partial Catalog Number)

S811N37

S811N66

S811R10

S811R13

S811T18

S811T24

S811T30

S811U36

S811U42

S811U50 �

S811V36

S811V42

S811V50

S811V65

S811V72

S811V85

S811V10 �

Max. Current Capacity 37 66 105 135 180 240 304 360 420 500 360 420 500 650 720 850 1000FLA Range 11 –

3720 – 66

32 – 105

42 – 135

56 – 180

75 – 240

95 – 304

112 – 360

131 – 420

156 – 500

112 – 360

131 – 420

156 – 500

203 – 650

225 – 720

265 – 580

320 – 1000

DimensionsWidth in Inches (mm) 2.66 (67.6) 4.38 (111.3) 7.67 (194.8) 7.73 (196.3) 11.05 (280.6)Height in Inches (mm) 7.38

(187.4)7.92 (201.2) 12.71 (322.9) 12.72 (323.1) 16.57 (420.8)

Depth in Inches (mm) 6.47 (164.4)

6.66 (169.2) 6.39 (162.4) 7.08 (179.9) 7.35 (186.6)

Weight in lbs. (kg) 5.8 (2.6) 10.5 (4.8) 48 (21.8) with lugs41 (18.6) without

lugs

48 (21.8) with lugs41 (18.6) without lugs

103 (46.8) with lugs91 (41.4) without lugs

General InformationBypass Mechanical Lifespan

10M

Insulating Voltage Ui 660VRamp Time Range .5 – 180 Seconds (.5 – 360 Seconds Extended Ramp)Resistance to Vibration 3gResistance to Shock 15g

Electrical InformationOperating Voltage 200 – 600VOperating Frequency 47 – 63 HzOverload Setting 30 – 100%Trip Class 5, 10, 20, & 30

Cabling Capacity (IEC 947)Number of Conductors 1 1 1 or 2 1 or 2 2, 4 or 6Wire Sizes 14 – 2 14 – 4/0 4 AWG to 500 MCM 4 AWG to 500 MCM 2/0 to 500 MCM Type of Connectors Box Lug Add-On Lug Kit

Control Wiring (12-Pin)Wire Sizes in AWG 22 – 14Number of Conductors (Stranded)

2 (or one AWG 12)

Torque Requirements in lb-in

3.5

Solid, Stranded or Flexible Max. Size in mm2

3.31

Control Power RequirementsVoltage Range (24V ± 10%) 21.6 – 26.4Steady State Current Amps

1.0 1.0 1.0 1.0 1.4

Inrush Current Amps 10 10 10 10 10Ripple 1%

Relays (1) Class A and CVoltage AC — maximum 240Voltage DC — maximum 120Amps — maximum 3

EnvironmentTemperature — Operating -30 – 50°C (No derating) Consult factory for operation > 50˚ CTemperature — Storage -50 – 70°CAltitude <2000 Meters — Consult factory for operation > 2000mHumidity <95% Non-condensingOperating Position AnyPollution degree IEC947-1 3Impulse withstand Voltage IEC947-4-1

6000V

Page 22: Contents Reduced Voltage Motor Starters

April 2007

22

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Dimensions

Figure 11. N-Frame (65 mm) S811 Approximate Dimensions in Inches (mm)

Figure 12. R-Frame (110 mm) S811 Approximate Dimensions in Inches (mm)

6.87(174.5)

1.97(50.0)

.22 (5.5)Typ.

4 Places

2.66(67.6)

3.46(88.0)

5.35(135.9)

6.47(164.4)

7.38(187.4)

3.49(88.5)

5.53(140.5)

6.66(169.2)

7.44(189.0)

3.54(90.0)

4.38(111.3)

7.92(201.2)

.27 (6.8)Typ.

4 Places

Page 23: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

23Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Figure 13. T-Frame (200 mm) S811 Approximate Dimensions in Inches (mm)

Figure 14. U-Frame (200 mm) S811 Approximate Dimensions in Inches (mm)

5.40(137.2)

6.39(162.4)

7.67(194.8)

11.77(299.0)Slots

12.71(322.9)

2.95(75.0)Slots

.28(7.1)

Slots Typ.6 Places

5.91 (150.0)Slots

11.77 (299.0)Mounting

5.20 (132.0)Mounting

Mounting Slotsfor M6 (1/4) Screws(Up to 6 Quantity)

.47(11.9)

7.08(179.9)

12.72(323.1)

7.73(196.3)

5.20 (132.0)Pole Centers

C L

C L

Page 24: Contents Reduced Voltage Motor Starters

April 2007

24

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM

Figure 15. V-Frame (290 mm) S811 Approximate Dimensions in Inches (mm)

3.74(95.0)

.26 (6.5) Dia.Typ.

4 Places

7.35(186.6)

15.16(385.0)Slots

15.63(397.0)

MountingHoles

16.57(420.8)

9.84(250.0)

11.05 (280.6).27 (6.8)Typ.

4 Places

Page 25: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

25Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedProduct Family Overview

ContentsDescription Page

IT. Solid-State Soft Starters — Enclosed

Product Family Overview . . . . . . . . . . . . . . . 25

Cover Control . . . . . . . . . . . . . 26

Catalog NumberSelection . . . . . . . . . . . . . . . 27

Non-combination

Product Selection. . . . . . . . . . 28

Combination with Fusible Disconnect

Product Selection. . . . . . . . . . 29

Combination with Breaker

Product Selection. . . . . . . . . . 30

Dimensions . . . . . . . . . . . . . . . . . 31

Product DescriptionEaton’s revolutionary design for soft starters is shown in the S752, S801 and S811 soft starter products which are members of the Cutler-Hammer® Intelligent Technologies (IT.) family of products. These Reduced Voltage Soft Starters are the most compact, multi-functional, easy-to-install products on the market. Their superiority begins with the control package, which fea-tures 24V DC control, onboard Digital Signal Processor (DSP), and use of a low impedance run contactor, all of which contribute to the IT. Soft Starter’s safety, advanced functionality and compact size.

Designed to control acceleration and deceleration of three-phase motors, products are available from .25 to 1000 amps and are suitable for mounting in a variety of enclosures including Type 1, 12, 3R, 4, 4X and 7/9.

■ Built-in overload protection❑ Adjustable trip class 5, 10, 20, 30❑ 30 – 100% FLA adjustment❑ Selectable phase loss protection

■ Selectable current limit or ramp start

■ Adjustable ramp times❑ 0 – 180 seconds standard❑ Extended ramps available

■ Adjustable torque control■ Adjustable kick start control■ Soft Stop control

❑ 0 – 60 seconds standard❑ Extended times available

■ Built-in low impedance contactor■ Six SCR Control in all units■ Selectable phase reversal protection■ Digital Interface Module

Features and Benefits■ Mechanical stress on system

❑ Reduced wear on belts, gears, chains, clutches, shafts and bear-ings. You can get up to 2 – 6 times the life on standard belts by switching to a soft starter.

❑ Elimination of water-hammer in pumping applications extends component life and helps limit leakage in system.

❑ Lower shock to product on con-veyor lines and material handling gear.

❑ Able to catch motors and fans on the fly and control their acceleration.

■ Electrical system improvements❑ Limits the peak inrush current as

required by many local codes. ❑ Helps to eliminate sags on the

plant electrical grid when starting large loads, thus avoiding brown-out conditions.

■ 24V DC advantages❑ Offers improved personnel safety

by eliminating the need for 120V AC in the enclosure.

❑ Soft Starter able to ride through 50% voltage conditions indefi-nitely due to 24V DC power supply and 0% for up to 100 mS.

■ 690V Option available on 180A ratings and larger

Digital Interface ModuleThe S811 has an easy to use Digital Interface Module (DIM) that allows the user to configure the device and to read system parameters. The DIM includes an LCD display and keypad to scroll through the various menus. The DIM allows the user to modify control parameters, enable or disable protec-tions, set communication variables, monitor system parameters such as line voltages and currents, and access the fault queue.

Digital Interface Module (DIM)

The DIM can be removed from the S811 and remote mounted. Kits are available to door mount the DIM, enabling users to safely configure, commission, monitor and trouble-shoot the system at the electrical panel without opening the enclosure door.

Enclosed 40 hp Soft StarterESC

ONLN SS OXFDO1 H STOP

Monitoring

PREV NEXT ENTER

Page 26: Contents Reduced Voltage Motor Starters

April 2007

26

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedProduct Family Overview

Standards and Certifications■ UL Listed■ IEC 947-4-2■ EN 60947.2 (for motor controller)■ cUL (indicates appropriate CSA

Standard investigation)■ ABS Type Approved

Options

Pump Control Option■ Designed to reduce “water-

hammer” during start-up and stopping sequences

■ Stop ramp extended to 120 seconds to help control larger motors and systems with long piping runs

LCD Display■ 2 line x 20 character LED back-lit

LCD display■ NEMA 4 rated■ Parameters

❑ Voltage L-L (AB, BC, AC) ❑ Phase Current❑ Average Current❑ Overload Current Setting❑ Pole Temperature❑ Relay Trip Class❑ Thermal Pile❑ Average Line Current as % of FLA❑ DC Control Voltage❑ Start Count❑ Fault History

■ English or Spanish version

Table 33. Options Description Modification

Code

Pump Control Option P42

LCD Display K5

Extended Ramp R1

Cover Control

Flange Control KitsFor on-the-job conversion of Type 1, 3R, 4, 4X and 12 enclosed starters. Knock-outs are provided on the Type 1 flange. Type 3R, 4, 4X and 12 have prepunched holes with removable hole plugs.

Factory Installed Pilot DevicesTo order factory installed pilot devices, change the 9th character of the Catalog Number to the alpha shown in the table below. Example: to order an ECS90J4CAA with START/STOP pushbuttons and a red pilot light, change the A to a C, i.e. ECS90J4CCA.

Table 34. Non-reversing Pilot Devices

� Add Code Letter from the table below to Catalog Number for voltage — Kits only. Example: C400T9B.

Description Factory InstalledFlange Control

Field Installation Kits

Position9 Alpha

AdderU.S. $

CatalogNumber

PriceU.S. $

No Cover Mounted Pilot DevicesSTART/STOP Pushbuttonswith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

ABCD

—224.00408.00592.00

—C400T1——

—99.50

——

ON/OFF Pushbuttonswith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

EFG

224.00408.00592.00

C400T2——

99.50——

HAND/OFF/AUTO Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

HJK

201.00385.00569.00

C400T12——

99.50——

START PushbuttonON PushbuttonOFF PushbuttonRed RUN Pilot LightGreen OFFRed RUN/Green OFF Pilot Lights

LMNPQR

224.00224.00224.00224.00224.00368.00

C400T3C400T4C400T5C400T9 �

C400T10 �

C400T11 �

68.5068.5068.50

197.00197.00365.00

START/STOP Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

STU

201.00385.00569.00

C400T13——

99.50——

ON/OFF Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

VWX

201.00385.00569.00

C400T14——

99.50——

Rating Code Letter Rating Code Letter Rating Code Letter

120V 60 Hz208V 60 Hz

AE

240V 60 Hz380V 50 Hz

BL

480V 60 Hz600V 60 Hz

CD

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C

Page 27: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

27Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedProduct Family Overview

Catalog Number SelectionTable 35. Solid-State Enclosed Control Catalog Numbering System

� DIM = Digital Interface Module.

E C S 9 0 S 1 C A A

Type

S = Solid-State

Class Page

93 = Non-combination S811 IT. Soft Start with DIM �94 = Combination S811 IT. Soft Start with Fusible

Disconnect and DIM �95 = Combination S811 IT. Soft Start with HMCP and

DIM �

2829

30

Amps

S752 S801/S811

J = .8K = 1.9L = 4.4M = 9N = 16P = 27R = 50

Q = 37S = 66V = 105W = 135Y = 180

Z = 2401 = 3042 = 3603 = 4204 = 500

5 = 6506 = 7207 = 8508 = 1000

Voltage

B = 230VC = 460VD = 575V

E = 200VQ = 24V DC

Cover Control

See Table 34 for Options

Disconnect Fuse Clip Ratings

A = NoneB = 30A/250V RC = 30A/600V RD = 60A/250V RE = 60A/600V RF = 100A/250V R

G = 100A/600V RH = 200A/250V RJ = 200A/600V RK = 400A/250V RL = 400A/600V RM = 600A/250V R

N = 600A/600V RP = 800A/600V LQ = 1200A/600V LR = 1600A/600V LS = 2000A/600V LT = by Description

Breaker

A = NoneB = 3AC = 7AD = 15AE = 30A

F = 50AW = 70AG = 100AH = 150AJ = 250A

K = 400AL = 600AP = 1200AQ = 1600A

Enclosure Type

1 = Type 12 = Type 3R3 = Type 44 = Type 4X (304-Grade SS)6 = Type 7/98 = Type 129 = Type 4X (316-Grade SS)

Page 28: Contents Reduced Voltage Motor Starters

April 2007

28

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedNon-combination

Table 36. Class ECS93 — S811 IT. Soft Starter Enclosures — Non-combination with DIM �

� All IT. soft starters are furnished with 24V DC coils and control power supplies. For 24V DC separate control, use Mod Code C35 and change the 8th digit to Q (i.e. ECS90S1EAA becomes ECS90S1QAA-C35).

� Standard duty horsepower ratings are for 300% ramp current, 30 seconds ramp time, and 3 starts per hour. Consult Eaton for other ratings.

� Based on 1.0 Service Factor. For 1.15 consult Eaton.

� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECS93S4EAA. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5.

� Digital Interface Module (DIM) is mounted on door as standard.

Amps MotorVoltage

hp��

CoilVoltage �

Type 1 Type 3R Type 4X � Type 7/9 Type 12 Component Soft Starter (Open)

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

Frame Size — 65 mm37A 200V

230V460V575V

10102530

24V DC ECS93Q1EAAECS93Q1BAAECS93Q1CAAECS93Q1DAA

ECS93Q2EAAECS93Q2BAAECS93Q2CAAECS93Q2DAA

ECS93Q4EAAECS93Q4BAAECS93Q4CAAECS93Q4DAA

ECS93Q6EAAECS93Q6BAAECS93Q6CAAECS93Q6DAA

ECS93Q8EAAECS93Q8BAAECS93Q8CAAECS93Q8DAA

S811N37N3S

66A 200V230V460V575V

20205060

24V DC ECS93S1EAAECS93S1BAAECS93S1CAAECS93S1DAA

ECS93S2EAAECS93S2BAAECS93S2CAAECS93S2DAA

ECS93S4EAAECS93S4BAAECS93S4CAAECS93S4DAA

ECS93S6EAAECS93S6BAAECS93S6CAAECS93S6DAA

ECS93S8EAAECS93S8BAAECS93S8CAAECS93S8DAA

S811N66N3S

Frame Size — 110 mm105A 200V

230V460V575V

304075

100

24V DC ECS93V1EAAECS93V1BAAECS93V1CAAECS93V1DAA

ECS93V2EAAECS93V2BAAECS93V2CAAECS93V2DAA

ECS93V4EAAECS93V4BAAECS93V4CAAECS93V4DAA

ECS93V6EAAECS93V6BAAECS93V6CAAECS93V6DAA

ECS93V8EAAECS93V8BAAECS93V8CAAECS93V8DAA

S811R10N3S

135A 200V230V460V575V

4050

100125

24V DC ECS93W1EAAECS93W1BAAECS93W1CAAECS93W1DAA

ECS93W2EAAECS93W2BAAECS93W2CAAECS93W2DAA

ECS93W4EAAECS93W4BAAECS93W4CAAECS93W4DAA

ECS93W6EAAECS93W6BAAECS93W6CAAECS93W6DAA

ECS93W8EAAECS93W8BAAECS93W8CAAECS93W8DAA

S811R13N3S

Frame Size — 200 mm180A 200V

230V460V575V

6060

150150

24V DC ECS93Y1EAAECS93Y1BAAECS93Y1CAAECS93Y1DAA

ECS93Y2EAAECS93Y2BAAECS93Y2CAAECS93Y2DAA

ECS93Y4EAAECS93Y4BAAECS93Y4CAAECS93Y4DAA

ECS93Y6EAAECS93Y6BAAECS93Y6CAAECS93Y6DAA

ECS93Y8EAAECS93Y8BAAECS93Y8CAAECS93Y8DAA

S811T18N3S

240A 200V230V460V575V

7575

200200

24V DC ECS93Z1EAAECS93Z1BAAECS93Z1CAAECS93Z1DAA

ECS93Z2EAAECS93Z2BAAECS93Z2CAAECS93Z2DAA

ECS93Z4EAAECS93Z4BAAECS93Z4CAAECS93Z4DAA

ECS93Z6EAAECS93Z6BAAECS93Z6CAAECS93Z6DAA

ECS93Z8EAAECS93Z8BAAECS93Z8CAAECS93Z8DAA

S811T24N3S

304A 200V230V460V575V

100100250300

24V DC ECS9311EAAECS9311BAAECS9311CAAECS9311DAA

ECS9312EAAECS9312BAAECS9312CAAECS9312DAA

ECS9314EAAECS9314BAAECS9314CAAECS9314DAA

ECS9316EAAECS9316BAAECS9316CAAECS9316DAA

ECS9318EAAECS9318BAAECS9318CAAECS9318DAA

S811T30N3S

Frame Size — 290 mm360A 200V

230V460V575V

125150300350

24V DC ECS9321EAAECS9321BAAECS9321CAAECS9321DAA

ECS9322EAAECS9322BAAECS9322CAAECS9322DAA

ECS9324EAAECS9324BAAECS9324CAAECS9324DAA

ECS9326EAAECS9326BAAECS9326CAAECS9326DAA

ECS9328EAAECS9328BAAECS9328CAAECS9328DAA

S811V36N3S

420A 200V230V460V575V

150175350450

24V DC ECS9331EAAECS9331BAAECS9331CAAECS9331DAA

ECS9332EAAECS9332BAAECS9332CAAECS9332DAA

ECS9334EAAECS9334BAAECS9334CAAECS9334DAA

ECS9336EAAECS9336BAAECS9336CAAECS9336DAA

ECS9338EAAECS9338BAAECS9338CAAECS9338DAA

S811V42N3S

500A 200V230V460V575V

150200400500

24V DC ECS9341EAAECS9341BAAECS9341CAAECS9341DAA

ECS9342EAAECS9342BAAECS9342CAAECS9342DAA

ECS9344EAAECS9344BAAECS9344CAAECS9344DAA

ECS9346EAAECS9346BAAECS9346CAAECS9346DAA

ECS9348EAAECS9348BAAECS9348CAAECS9348DAA

S811V50N3S

650A 200V230V460V575V

250250500600

24V DC ECS9351EAAECS9351BAAECS9351CAAECS9351DAA

ECS9352EAAECS9352BAAECS9352CAAECS9352DAA

ECS9354EAAECS9354BAAECS9354CAAECS9354DAA

ECS9356EAAECS9356BAAECS9356CAAECS9356DAA

ECS9358EAAECS9358BAAECS9358CAAECS9358DAA

S811V65N3S

720A 230V460V575V

300600700

24V DC ECS9361BAAECS9361CAAECS9361DAA

ECS9362BAAECS9362CAAECS9362DAA

ECS9364BAAECS9364CAAECS9364DAA

ECS9366BAAECS9366CAAECS9366DAA

ECS9368BAAECS9368CAAECS9368DAA

S811V72N3S

850A 230V460V575V

350700900

24V DC ECS9371BAAECS9371CAAECS9371DAA

ECS9372BAAECS9372CAAECS9372DAA

ECS9374BAAECS9374CAAECS9374DAA

ECS9376BAAECS9376CAAECS9376DAA

ECS9378BAAECS9378CAAECS9378DAA

S811V85N3S

1000A 230V460V575V

400800

1000

24V DC ECS9381BAAECS9381CAAECS9381DAA

ECS9382BAAECS9382CAAECS9382DAA

ECS9384BAAECS9384CAAECS9384DAA

ECS9386BAAECS9386CAAECS9386DAA

ECS9388BAAECS9388CAAECS9388DAA

S811V10N3S

Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . Page 21

Page 29: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

29Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedCombination with Fusible Disconnect

Table 37. Class ECS94 – S811 IT. Soft Starter Enclosures — Combination with Fusible Disconnect and DIM �

� All IT. soft starters are furnished with 24V DC coils and control power supplies. For 24V DC separate control, use Mod Code C35 and change the 8th digit to Q (i.e. ECS90S1EAA becomes ECS90S1QAA-C35).

� Standard duty horsepower ratings are for 300% ramp current, 30 seconds ramp time, and 3 starts per hour. Consult Eaton for other ratings.

� Based on 1.0 Service Factor. For 1.15 consult Eaton.

� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECS94S4EAA. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5.

� Consult Eaton.

� Digital Interface Module (DIM) is mounted on door as standard.

Amps MotorVoltage

hp��

CoilVoltage �

SwitchRating

Type 1 Type 3R Type 4X � Type 12 Component Soft Starter (Open)

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

Frame Size — 65 mm37A 200V 3

1024V DC 30A

60AECS94Q1EABECS94Q1EAD

ECS94Q2EABECS94Q2EAD

ECS94Q4EABECS94Q4EAD

ECS94Q8EABECS94Q8EAD

S811N37N3S

230V 7-1/210

30A60A

ECS94Q1BABECS94Q1BAD

ECS94Q2BABECS94Q2BAD

ECS94Q4BABECS94Q4BAD

ECS94Q8BABECS94Q8BAD

S811N37N3S

460V 1525

30A60A

ECS94Q1CACECS94Q1CAE

ECS94Q2CACECS94Q2CAE

ECS94Q4CACECS94Q4CAE

ECS94Q8CACECS94Q8CAE

S811N37N3S

575V 2030

30A60A

ECS94Q1DACECS94Q1DAE

ECS94Q2DACECS94Q2DAE

ECS94Q4DACECS94Q4DAE

ECS94Q8DACECS94Q8DAE

S811N37N3S

66A 200V 1020

24V DC 60A100A

ECS94S1EADECS94S1EAF

ECS94S2EADECS94S2EAF

ECS94S4EADECS94S4EAF

ECS94S8EADECS94S8EAF

S811N66N3S

230V 1520

60A100A

ECS94S1BADECS94S1BAF

ECS94S2BADECS94S2BAF

ECS94S4BADECS94S4BAF

ECS94S8BADECS94S8BAF

S811N66N3S

460V 50 100A ECS94S1CAG ECS94S2CAG ECS94S4CAG ECS94S8CAG S811N66N3S

575V 4060

60A100A

ECS94S1DAEECS94S1DAG

ECS94S2DAEECS94S2DAG

ECS94S4DAEECS94S4DAG

ECS94S8DAEECS94S8DAG

S811N66N3S

Frame Size — 110 mm105A 200V

230V460V575V

304075100

24V DC 200A200A200A200A

ECS94V1EAHECS94V1BAHECS94V1CAJECS94V1DAJ

ECS94V2EAHECS94V2BAHECS94V2CAJECS94V2DAJ

ECS94V4EAHECS94V4BAHECS94V4CAJECS94V4DAJ

ECS94V8EAHECS94V8BAHECS94V8CAJECS94V8DAJ

S811R10N3S

135A 200V230V460V575V

4050100125

24V DC 200A200A200A200A

ECS94W1EAHECS94W1BAHECS94W1CAJECS94W1DAJ

ECS94W2EAHECS94W2BAHECS94W2CAJECS94W2DAJ

ECS94W4EAHECS94W4BAHECS94W4CAJECS94W4DAJ

ECS94W8EAHECS94W8BAHECS94W8CAJECS94W8DAJ

S811R13N3S

Frame Size — 200 mm180A 200V

230V460V575V

6060150150

24V DC 400A400A400A400A

ECS94Y1EAKECS94Y1BAKECS94Y1CALECS94Y1DAL

ECS94Y2EAKECS94Y2BAKECS94Y2CALECS94Y2DAL

ECS94Y4EAKECS94Y4BAKECS94Y4CALECS94Y4DAL

ECS94Y8EAKECS94Y8BAKECS94Y8CALECS94Y8DAL

S811T18N3S

240A 200V230V460V575V

7575200200

24V DC 400A400A400A400A

ECS94Z1EAKECS94Z1BAKECS94Z1CALECS94Z1DAL

ECS94Z2EAKECS94Z2BAKECS94Z2CALECS94Z2DAL

ECS94Z4EAKECS94Z4BAKECS94Z4CALECS94Z4DAL

ECS94Z8EAKECS94Z8BAKECS94Z8CALECS94Z8DAL

S811T24N3S

304A 200V230V460V575V

100100250300

24V DC 400A400A400A400A

ECS9411EAKECS9411BAKECS9411CALECS9411DAL

ECS9412EAKECS9412BAKECS9412CALECS9412DAL

ECS9414EAKECS9414BAKECS9414CALECS9414DAL

ECS9418EAKECS9418BAKECS9418CALECS9418DAL

S811T30N3S

Frame Size — 290 mm360A 200V

230V460V575V

125125300350

24V DC 600A600A600A600A

ECS9421EAMECS9421BAMECS9421CANECS9421DAN

ECS9422EAMECS9422BAMECS9422CANECS9422DAN

ECS9424EAMECS9424BAMECS9424CANECS9424DAN

ECS9428EAMECS9428BAMECS9428CANECS9428DAN

S811V36N3S

420A 200V230V460V575V

150150350450

24V DC 600A600A600A600A

ECS9431EAMECS9431BAMECS9431CANECS9431DAN

ECS9432EAMECS9432BAMECS9432CANECS9432DAN

ECS9434EAMECS9434BAMECS9434CANECS9434DAN

ECS9438EAMECS9438BAMECS9438CANECS9438DAN

S811V42N3S

500A 200V230V460V575V

150200400500

24V DC 800A800A800A800A

ECS9441EAPECS9441BAPECS9441CAPECS9441DAP

ECS9442EAPECS9442BAPECS9442CAPECS9442DAP

ECS9444EAPECS9444BAPECS9444CAPECS9444DAP

ECS9448EAPECS9448BAPECS9448CAPECS9448DAP

S811V50N3S

650A 460V575V

500600

24V DC 800A800A

ECS9451CAPECS9451DAP

ECS9452CAPECS9452DAP

ECS9454CAPECS9454DAP

ECS9458CAPECS9458DAP

S811V65N3S

720A 460V575V

600700

24V DC 1200A1200A

ECS9461CAQECS9461DAQ

ECS9462CAQECS9462DAQ

ECS9464CAQECS9464DAQ

ECS9468CAQECS9468DAQ

S811V72N3S

850A 460V575V

700800

24V DC 1600A1600A

ECS9471CARECS9471DAR

ECS9472CARECS9472DAR

ECS9474CARECS9474DAR

ECS9478CARECS9478DAR

S811V85N3S

1000A 230V460V575V

4008001000

24V DC ���

ECS9481BA_ �

ECS9481CA_ �

ECS9481DA_ �

ECS9482BA_ �

ECS9482CA_ �

ECS9482DA_ �

ECS9484BA_ �

ECS9484CA_ �

ECS9484DA_ �

ECS9488BA_ �

ECS9488CA_ �

ECS9488DA_ �

S811V10N3S

Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19Technical Data . . . . . . . . . . . . . . . . . . . . . . . . Page 21

Page 30: Contents Reduced Voltage Motor Starters

April 2007

30

For more information visit: www.eaton.com CA03902004E

Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedCombination with Breaker

Table 38. Class ECS95 — S811 IT. Soft Starter Enclosures — Combination with Breaker and DIM �

� All IT. soft starters are furnished with 24V DC coils and control power supplies. For 24V DC separate control, use Mod Code C35 and change the 8th digit to Q (i.e. ECS90S1EAA becomes ECS90S1QAA-C35).

� Standard duty horsepower ratings are for 300% ramp current, 30 seconds ramp time, and 3 starts per hour. Consult Eaton for other ratings.

� Based on 1.0 Service Factor. For 1.15 consult Eaton.

� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECS95S4EAA. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5.

� Digital Interface Module (DIM) is mounted on door as standard.

Amps MotorVoltage

hp��

1.0S.F.

CoilVoltage �

CircuitBreakerType

Type 1 Type 3R Type 4X � Type 7/9 Type 12 Component Soft Starter (Open)

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

Frame Size 65 mm37A 200V 1/2

1310

24V DC 7A15A30A50A

ECS95Q1EACECS95Q1EADECS95Q1EAEECS95Q1EAF

ECS95Q2EACECS95Q2EADECS95Q2EAEECS95Q2EAF

ECS95Q4EACECS95Q4EADECS95Q4EAEECS95Q4EAF

ECS95Q6EACECS95Q6EADECS95Q6EAEECS95Q6EAF

ECS95Q8EACECS95Q8EADECS95Q8EAEECS95Q8EAF

S811N37N3S

230V 12310

24V DC 7A15A30A50A

ECS95Q1BACECS95Q1BADECS95Q1BAEECS95Q1BAF

ECS95Q2BACECS95Q2BADECS95Q2BAEECS95Q2BAF

ECS95Q4BACECS95Q4BADECS95Q4BAEECS95Q4BAF

ECS95Q6BACECS95Q6BADECS95Q6BAEECS95Q6BAF

ECS95Q8BACECS95Q8BADECS95Q8BAEECS95Q8BAF

S811N37N3S

460V 3/4251025

24V DC 3A7A15A30A50A

ECS95Q1CABECS95Q1CACECS95Q1CADECS95Q1CAEECS95Q1CAF

ECS95Q2CABECS95Q2CACECS95Q2CADECS95Q2CAEECS95Q2CAF

ECS95Q4CABECS95Q4CACECS95Q4CADECS95Q4CAEECS95Q4CAF

ECS95Q6CABECS95Q6CACECS95Q6CADECS95Q6CAEECS95Q6CAF

ECS95Q8CABECS95Q8CACECS95Q8CADECS95Q8CAEECS95Q8CAF

S811N37N3S

575V 137-1/21530

24V DC 3A7A15A30A50A

ECS95Q1DABECS95Q1DACECS95Q1DADECS95Q1DAEECS95Q1DAF

ECS95Q2DABECS95Q2DACECS95Q2DADECS95Q2DAEECS95Q2DAF

ECS95Q4DABECS95Q4DACECS95Q4DADECS95Q4DAEECS95Q4DAF

ECS95Q6DABECS95Q6DACECS95Q6DADECS95Q6DAEECS95Q6DAF

ECS95Q8DABECS95Q8DACECS95Q8DADECS95Q8DAEECS95Q8DAF

S811N37N3S

66A 200V 1020

24V DC 50A100A

ECS95S1EAFECS95S1EAG

ECS95S2EAFECS95S2EAG

ECS95S4EAFECS95S4EAG

ECS95S6EAFECS95S6EAG

ECS95S8EAFECS95S8EAG

S811N66N3S

230V 1520

24V DC 70A100A

ECS95S1BAWECS95S1BAG

ECS95S2BAWECS95S2BAG

ECS95S4BAWECS95S4BAG

ECS95S6BAWECS95S6BAG

ECS95S8BAWECS95S8BAG

S811N66N3S

460V 50 24V DC 100A ECS95S1CAG ECS95S2CAG ECS95S4CAG ECS95S6CAG ECS95S8CAG S811N66N3S

575V 60 24V DC 100A ECS95S1DAG ECS95S2DAG ECS95S4DAG ECS95S6DAG ECS95S8DAG S811N66N3S

Frame Size 110 mm105A 200V 30 24V DC 150A ECS95V1EAH ECS95V2EAH ECS95V4EAH ECS95V6EAH ECS95V8EAH S811R10N3S

230V 40 24V DC 150A ECS95V1BAH ECS95V2BAH ECS95V4BAH ECS95V6BAH ECS95V8BAH S811R10N3S

460V 75 24V DC 150A ECS95V1CAH ECS95V2CAH ECS95V4CAH ECS95V6CAH ECS95V8CAH S811R10N3S

575V 100 24V DC 150A ECS95V1DAH ECS95V2DAH ECS95V4DAH ECS95V6DAH ECS95V8DAH S811R10N3S

135A 200V230V460V575V

4050100125

24V DC 150A150A150A150A

ECS95W1EAHECS95W1BAHECS95W1CAHECS95W1DAH

ECS95W2EAHECS95W2BAHECS95W2CAHECS95W2DAH

ECS95W4EAHECS95W4BAHECS95W4CAHECS95W4DAH

ECS95W6EAHECS95W6BAHECS95W6CAHECS95W6DAH

ECS95W8EAHECS95W8BAHECS95W8CAHECS95W8DAH

S811R13N3S

Frame Size 200 mm180A 200V

230V460V575V

6060150150

24V DC 250A250A250A250A

ECS95Y1EAJECS95Y1BAJECS95Y1CAJECS95Y1DAJ

ECS95Y2EAJECS95Y2BAJECS95Y2CAJECS95Y2DAJ

ECS95Y4EAJECS95Y4BAJECS95Y4CAJECS95Y4DAJ

ECS95Y6EAJECS95Y6BAJECS95Y6CAJECS95Y6DAJ

ECS95Y8EAJECS95Y8BAJECS95Y8CAJECS95Y8DAJ

S811T18N3S

240A 200V230V460V575V

7575200200

24V DC 400A250A400A250A

ECS95Z1EAKECS95Z1BAJECS95Z1CAKECS95Z1DAJ

ECS95Z2EAKECS95Z2BAJECS95Z2CAKECS95Z2DAJ

ECS95Z4EAKECS95Z4BAJECS95Z4CAKECS95Z4DAJ

ECS95Z6EAKECS95Z6BAJECS95Z6CAKECS95Z6DAJ

ECS95Z8EAKECS95Z8BAJECS95Z8CAKECS95Z8DAJ

S811T24N3S

304A 200V230V460V575V

100100250300

24V DC 400A400A400A400A

ECS9511EAKECS9511BAKECS9511CAKECS9511DAK

ECS9512EAKECS9512BAKECS9512CAKECS9512DAK

ECS9514EAKECS9514BAKECS9514CAKECS9514DAK

ECS9516EAKECS9516BAKECS9516CAKECS9516DAK

ECS9518EAKECS9518BAKECS9518CAKECS9518DAK

S811T30N3S

Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . Page 21

Page 31: Contents Reduced Voltage Motor Starters

April 2007

CA03902004E For more information visit: www.eaton.com

31Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedDimensions

Table 38. Class ECS95 — S811 IT. Soft Starter Enclosures — Combination with Breaker and DIM � (Continued)

� All IT. soft starters are furnished with 24V DC coils and control power supplies. For 24V DC separate control, use Mod Code C35 and change the 8th digit to Q (i.e. ECS92S1EAF becomes ECS92S1QAF-C35).

� Standard duty horsepower ratings are for 300% ramp current, 30 seconds ramp time, and 3 starts per hour. Consult Eaton for other ratings.

� Based on 1.0 Service Factor. For 1.15 consult Eaton.

� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECS95S4EAA. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5.

� Digital Interface Module (DIM) is mounted on door as standard.

DimensionsTable 39. Minimum Enclosure Box Numbers

� Enclosure space will also accommodate for an IT. Power Supply, two 4-pole relays, CPT, and terminal blocks. Also includes space for a DNA module or MOV.

� Same as footnote �, but CPT is not included. Upsize to 7A enclosure to include space for a CPT and a full voltage bypass contactor.

Enclosure may be reduced to an A1, with all space for all items as in footnote �, excluding relays and CPTs.

Same as footnote �, but CPT is not included. Upsize to B1 enclosure to include space for a CPT and a full voltage bypass contactor.

Note: See Enclosed Control Product Focus for Box Dimensions for Type 1, 3R, 4X, 7/9 and 12.

Amps MotorVoltage

hp��

1.0S.F.

CoilVoltage �

CircuitBreakerType

Type 1 Type 3R Type 4X � Type 7/9 Type 12 Component Soft Starter (Open)

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

CatalogNumber

Frame Size 290 mm360A 200V

230V460V575V

125150300350

24V DC HMCP 600AHMCP 400AHMCP 600AHMCP 400A

ECS9521EALECS9521BAKECS9521CALECS9521DAK

ECS9522EALECS9522BAKECS9522CALECS9522DAK

ECS9524EALECS9524BAKECS9524CALECS9524DAK

————

ECS9528EALECS9528BAKECS9528CALECS9528DAK

S811V36N3S

420A 200V460V575V

150350450

24V DC HMCP 600AHMCP 600AHMCP 600A

ECS9531EALECS9531CALECS9531DAL

ECS9532EALECS9532CALECS9532DAL

ECS9534EALECS9534CALECS9534DAL

———

ECS9538EALECS9538CALECS9538DAL

S811V42N3S

500A 230V460V575V

200400500

24V DC HMCP 600AHMCP 600AHMCP 600A

ECS9541BALECS9541CALECS9541DAL

ECS9542BALECS9542CALECS9542DAL

ECS9544BALECS9544CALECS9544DAL

———

ECS9548BALECS9548CALECS9548DAL

S811V50N3S

650A 200V230V460V460V575V

200250450500600

24V DC HMCP 1200AHMCP 1200AHMCP 600AHMCP 1200AHMCP 1200A

ECS9551EAPECS9551BAPECS9551CALECS9551CAPECS9551DAP

ECS9552EAPECS9552BAPECS9552CALECS9552CAPECS9552DAP

ECS9554EAPECS9554BAPECS9554CALECS9554CAPECS9554DAP

—————

ECS9558EAPECS9558BAPECS9558CALECS9558CAPECS9558DAP

S811V65N3S

720A 230V460V575V

300600700

24V DC HMCP 1200AHMCP 1200AHMCP 1200A

ECS9561BAPECS9561CAPECS9561DAP

ECS9562BAPECS9562CAPECS9562DAP

ECS9564BAPECS9564CAPECS9564DAP

———

ECS9568BAPECS9568CAPECS9568DAP

S811V72N3S

850A 460V575V

700800

24V DC HMCP 1200AHMCP 1200A

ECS9571CAPECS9571DAP

ECS9572CAPECS9572DAP

ECS9574CAPECS9574DAP

——

ECS9578CAPECS9578DAP

S811V85N3S

1000A 230V460V575V

400800

1000

24V DC RD 1600RD 1600RD 1600

ECS9581BAQECS9581CAQECS9581DAQ

ECS9582BAQECS9582CAQECS9582DAQ

ECS9584BAQECS9584CAQECS9584DAQ

———

ECS9588BAQECS9588CAQECS9588DAQ

S811V10N3S

Rating SSRV Non-combination

Combination with Fuses

Combination with HMCP

Box No. � Box No. � Box No. �

.8 – 27A37A50A66A

105A135A180A

S752S801/S811S752S801/S811S801/S811S801/S811S801/S811

6A �7A6A �7A7AB1C

B1 B1CCDDE

A1 A1 A1 A1 B1CE

240A304A360A420A500A

S801/S811S801/S811S801/S811S801/S811S801/S811

G1G1G11010

F1EF1EF1EF1EF1E

EEEEE

650A720A850A

S801/S811S801/S811S801/S811

101010

F1EF1EF1E

F1EF1EF1E

1000A S801/S811 10 F1E F1E

Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19Technical Data . . . . . . . . . . . . . . . . . . . . . . . . Page 21

Page 32: Contents Reduced Voltage Motor Starters

Eaton CorporationElectrical Group1000 Cherrington ParkwayMoon Township, PA 15108United States877-ETN CARE (877-386-2273)Eaton.com

© 2007 Eaton CorporationAll Rights ReservedPrinted in USAPublication No. CA03902004E/CPGApril 2007