copyright reserved · 2019-09-06 · pole mounted luminaire (single head) photocell (exterior, type...
TRANSCRIPT
M
DM
A
V
K
H O A
D/I
DMM
#
#
G L H
G L H
G
PANELN2A
42POS
PANELN2A
STRIP LUMINAIRE (LENGTH AS PER LUMINAIRE SCHEDULE)
SURFACE OR SUSPENDED MOUNTED LUMINAIRE, 305x1220mm (1'x4')
WALL MOUNTED EXIT SIGN (TEXT ON SHADED SIDES, ARROWS AS INDICATED)
CEILING MOUNTED EXIT SIGN (TEXT ON SHADED SIDES, ARROWS AS INDICATED)
RECESSED LUMINAIRE / DOWN LIGHT
WALL MOUNTED LINEAR LUMINAIRE, 1220mm (4')
RECESSED LUMINAIRE, 305x1220mm (1'x4')
LUMINAIRE ON EMERGENCY CIRCUIT (INDICATED BY SHADING)
CEILING MOUNTED INFRARED LIGHTING OCCUPANCY SENSOR (DT=DUAL TECHNOLOGY)
4-GANG LINE VOLTAGE SWITCH
WALL MOUNTED EMERG. LTG. REMOTE HEAD (# OF LAMPS AS SHOWN)
KEY OPERATED SWITCH
EMERG. LTG. BATTERY PACK (# OF LAMPS AS SHOWN)
ELECTRONIC PROGRAMMABLE TIMER SWITCH
LINE VOLTAGE SWITCH c/w PILOT LIGHT
LINE VOLTAGE THREE WAY SWITCH
LINE VOLTAGE TWO POLE SWITCH
LINE VOLTAGE DIMMER SWITCH
3-GANG LINE VOLTAGE SWITCH
2-GANG LINE VOLTAGE SWITCH
LOW VOLTAGE SWITCH (30V OR LESS)
LINE VOLTAGE SWITCH
TRACK LIGHT (# OF HEADS AS SHOWN, LENGTH AS INDICATED)
POLE MOUNTED LUMINAIRE (SINGLE HEAD)
PHOTOCELL (EXTERIOR, TYPE AS INDICATED)
LIGHTING PLAN SYMBOLS
RECESSED LUMINAIRE, 610x1220mm (2'x4')
RECESSED LUMINAIRE, 610x610mm (2'x2')
SURFACE OR SUSPENDED MOUNTED, 610x1220mm (2'x4')
SURFACE OR SUSPENDED MOUNTED LUMINAIRE, 610x610mm (2'x2')
SURFACE MOUNTED OR SUSPENDED LUMINAIRE
WALL MOUNTED LUMINAIRE (S-STEP)
LINE VOLTAGE FOUR WAY SWITCH
WALL MOUNTED INFRARED LIGHTING OCCUPANCY SENSOR (DT=DUAL TECHNOLOGY)
CEILING MOUNTED EMERG. LTG. REMOTE HEAD (# OF LAMPS AS SHOWN)
LOW VOLTAGE DIMMER SWITCH
BOLLARD OR IN-GROUND LUMINAIRE
LINE VOLTAGE SWITCH c/w OCCUPANCY SENSOR
LOW VOLTAGE SWITCH c/w OCCUPANCY SENSOR
DAYLIGHT SENSOR (INTERIOR PHOTOCELL, TYPE AS INDICATED)
D
D
OS
OS
P
2
3
4
T
K
OS
EMERG. LTG. BATTERY PACK AND EXIT COMBO
LIGHTING ANNOTATION LEGEND
LUMINAIRE TYPE (SCHEDULE REFERENCE)
SWITCH LEG
PANEL AND CIRCUITaX-13
CONDUIT STUB
CONDUIT UP
CONDUIT DOWN
ELECTRICAL PANEL
MAGNETIC MOTOR STARTER
SINGLE 5-20R RECEPTACLE
QUADPLEX 5-20R RECEPTACLE
CEILING MOUNTED JUNCTION BOX
SPECIAL RECEPTACLE (TYPE AS INDICATED)
SPLIT CIRCUIT DUPLEX 5-15R RECEPTACLE
REEL CORD RECEPTACLE
FLOOR MOUNTED DUPLEX RECEPTACLE
SERVICE COLUMN / PACK POLE (NUMBER OF OUTLETS AS INDICATED)
CEILING MOUNTED DUPLEX RECEPTACLE
WALL MOUNTED JUNCTION BOX
MANUAL MOTOR STARTER c/w PILOT LIGHT
MOTOR c/w DISCONNECT SWITCH
DISCONNECT SWITCH
MOTOR
DUPLEX 5-20R RECEPTACLE, T-SLOT
FLOOR MOUNTED JUNCTION BOX
THERMOSTAT
GROUNDING / BONDING BUS BAR
COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT
POWER PLAN SYMBOLS
DOT DENOTES DEVICE MOUNTED ABOVE MILLWORK COUNTERTOP
DUPLEX 5-15R RECEPTACLE
DUPLEX 5-15R RECEPTACLE C/W INTEGRAL GFCI PROTECTION
FUSED DISCONNECT SWITCH
J
J
J
T
PANEL (TYPE AS INDICATED - SECURITY, LIGHTING RELAY, ETC.)
VFD VARIABLE FREQUENCY DRIVE
WALL MOUNTED OUTLET (C = CATV, F = FIBRE, I = INTERCOM, H = HDMI, X = XLR)
CEILING MOUNTED OUTLET
WALL MOUNTED VOICE & DATA OUTLET (# DENOTES NUMBER OF OUTLETS)
WIRELESS ACCESS POINT PROVIDE DATA OUTLET
COMMUNICATION SYMBOLS
FLOOR MOUNTED VOICE & DATA OUTLET (# DENOTES NUMBER OF OUTLETS)
CEILING MOUNTED VOICE & DATA OUTLET (# DENOTES NUMBER OF OUTLETS)
FLOOR MOUNTED OUTLET
WALL MOUNTED DATA OUTLET (# DENOTES NUMBER OF OUTLETS)
WALL MOUNTED TELEPHONE OUTLET
#
C
FIRE ALARM SYMBOLS
WALL MOUNTED HORN
WALL MOUNTED BELL ANNUNCIATOR
MANUAL STATION
FIRE ALARM SMOKE DETECTOR
FIRE ALARM HEAT DETECTOR (RATE OF RISE UNLESS OTHERWISE INDICATED)
MAGNETIC DOOR HOLDER
FIRE ALARM DUCT SMOKE DETECTOR
TAMPER SWITCH
FLOW SWITCH
PRESSURE SWITCH
WALL MOUNTED FIRE SPEAKER
CEILING STROBE
FIRE ALARM ANNUNCIATOR PANEL
WALL MOUNTED STROBE
FIRE ALARM CONTROL MODULE
FIRE ALARM MONITOR MODULE
FIRE ALARM FAULT ISOLATION MODULE
CARBON MONOXIDE DETECTOR
FIRE ALARM CONTROL PANEL
CENTRAL ALARM & CONTROL FACILITY
END OF LINE RESISTOR
CEILING MOUNTED FIRE SPEAKER WITH STROBE
WALL MOUNTED BELL ANNUNCIATOR AND STROBE
WALL MOUNTED HORN AND STROBE
WALL MOUNTED FIRE SPEAKER WITH STROBE
CEILING MOUNTED FIRE SPEAKER
120V SMOKE ALARM (CO DENOTES INTEGRAL CARBON MONOXIDE DETECTOR)
NOTE REFERENCE
REVISION NUMBER
EQUIPMENT REFERENCE
GENERAL SYMBOLS
WIRING HOME RUN
ABBREVIATIONS
EX
RE
RL
ER
BMS
CC
CM
CW
DGS
DW
EL
FAX
GF
HK
JB
MCC
MGAP
MW
N/C
PL
PM
PTR
SB
TR
TV
TYP
WP
N/O
DIC
EXISTING DEVICE TO REMAIN
REMOVE EXISTING DEVICE
RELOCATE EXISTING DEVICE
EXISTING DEVICE IN RELOCATED POSITION
BUILDING MANAGEMENT SYSTEM
CRASH CART
COFFEE MACHINE
CODE WHITE
DIAGNOSTIC SET
DISHWASHER
EXAMINATION LIGHT
FAX MACHINE
GROUND FAULT CIRCUIT INTERRUPTER
HOUSEKEEPING
JUNCTION BOX
MOTOR CONTROL CENTER
MEDICAL GAS ALARM PANEL
MICROWAVE
PATIENT LIFT
PATIENT MONITOR
PRINTER
SOUNDER BASE
TAMPER RESISTANT
TELEVISION
TYPICAL
WEATHERPROOF
NORMALLY CLOSED
NORMALLY OPEN
DICTATION
RP REPLACE EXISTING DEVICE WITH NEW DEVICE
AFG ABOVE FINISHED GRADE
AFF ABOVE FINISHED FLOOR
OC ON CENTER
SPD SURGE PROTECTIVE DEVICE
REF REFRIGERATOR
CP CODE PINK
IG ISOLATED GROUND
PATIENT WANDERING SYSTEM READER CONTROLLER
PATIENT WANDERING SYSTEM DETECTOR/EXCITER SENSOR
PANIC/DURESS PUSHBUTTON
CARD READER
DOOR POSITION SWITCH
GLASS BREAK DETECTOR
WALL MOUNTED SECURITY CAMERA, PAN/TILT/ZOOM
WALL MOUNTED SECURITY MOTION DETECTOR
CEILING MOUNTED SECURITY MOTION DETECTOR
REQUEST-TO-EXIT PUSHBUTTON
SECURITY KEY PAD (IA-INFANT ABDUCTION, PW-PATIENT WANDERING)
ELECTRIC STRIKE
WALL MOUNTED SECURITY CAMERA, FIXED
BUZZER
CEILING MOUNTED SECURITY CAMERA, FIXED
CEILING MOUNTED SECURITY CAMERA, PAN/TILT/ZOOM
INFANT ABDUCTION SYSTEM READER CONTROLLER
INFANT ABDUCTION SYSTEM DETECTOR/EXCITER SENSOR
CARD READER / KEY PAD COMBINATION
KEY SWITCH OVERRIDE
ELECTROMAGNETIC LOCK
SECURITY SYMBOLS
REQUEST-TO-EXIT MOTION SENSOR
PUSHBUTTON
WALL MOUNTED SINGLE FACED CLOCK
WALL MOUNTED DOUBLE FACED CLOCK
CEILING MOUNTED SINGLE FACED CLOCK
CEILING MOUNTED DOUBLE FACED CLOCK
WALL MOUNTED ELAPSED TIME CLOCK
CLOCK SYMBOLS
PUBLIC ADDRESS & AUDIO-VISUAL SYMBOLS
VOLUME CONTROL
BUZZER
CHIME
HORN
CEILING MOUNTED SPEAKER
WALL MOUNTED SPEAKERS
H
LOW VOLTAGE CIRCUIT BREAKER
LIGHTNING ARRESTOR
GENERATOR
CURRENT TRANSFORMER (# INDICATES NUMBER OF CTs IN GROUP)
POTENTIAL TRANSFORMER (# INDICATES NUMBER OF PTs IN GROUP)
PANELBOARD
DELTA CONNECTION
WYE CONNECTION
GROUND CONNECTION
DRAW OUT LOW VOLTAGE CIRCUIT BREAKER
DISCONNECT SWITCH
FUSE
TRANSFORMER
MAGNETIC MOTOR STARTER
TRANSFER SWITCH
NORMALLY OPEN CONTACT
NORMALLY CLOSED CONTACT
REVENUE METER
LOAD BREAK SWITCH
HIGH VOLTAGE CIRCUIT BREAKER
AUTOMATIC TRANSFER SWITCH C/W DUAL ISOLATION/BYPASS
GROUND BUS
PUSH PULL SWITCH
AMMETER
KEY SWITCH/KEY INTERLOCK
VOLTMETER
CONNECTION
RESISTOR
SPACE HEATER
LIGHT
PROBE SENSOR - WET WELL APPLICATION
FLOW SWITCH, NORMALLY CLOSED
FLOW SWITCH, NORMALLY OPEN
LEVEL SWITCH, NORMALLY CLOSED
LEVEL SWITCH, NORMALLY OPEN
PRESSURE SWITCH, NORMALLY CLOSED
PRESSURE SWITCH, NORMALLY OPEN
PUSH BUTTON MOMENTARY CONTACT, NORMALLY CLOSED
PUSH BUTTON MOMENTARY CONTACT, NORMALLY OPEN
NORMALLY-CLOSED, TIMED-CLOSED CONTACT (TIME DELAY ON DE-ENERGIZATION)
NORMALLY-CLOSED, TIMED-OPEN CONTACT (TIME DELAY ON ENERGIZATION)
NORMALLY-OPEN, TIMED-OPEN CONTACT (TIME DELAY ON DE-ENERGIZATION)
NORMALLY-OPEN, TIMED-CLOSED CONTACT (TIME DELAY ON ENERGIZATION)
THERMAL SWITCH, NORMALLY CLOSED
THERMAL SWITCH, NORMALLY OPEN
LIMIT SWITCH, NORMALLY CLOSED
LIMIT SWITCH, NORMALLY OPEN
HAND-OFF-AUTO SWITCH
INDUCTOR/REACTOR/CHOKE COIL
MANUAL MOTOR STARTER
MOTOR OVERLOAD
DOOR INTERLOCK SWITCH
DRAW OUT HIGH VOLTAGE CIRCUIT BREAKER
SCHEMATIC SYMBOLS
AUTOMATIC TRANSFER SWITCH C/W SINGLE ISOLATION/BYPASS
AUTOTRANSFORMER
BREAK LINE
CONTINUATION BREAK
ZERO SEQUENCE CURRENT TRANSFORMER
POTHEAD
CAPACITOR
SURGE PROTECTIVE DEVICE
COMBINATION MAGNETIC MOTOR STARTER
DIGITAL MULTIMETER
OS
PCPC
DSDS
FORCED AIR WALL HEATER
BASE BOARD HEATER (BLACK SQUARE INDICATES INTEGRAL THERMOSTAT)
SECURITY HORN
GROUND ROD
DOTS DENOTES SUSPENDED LUMINAIRE
DRY ALARM SWITCH
# # #
WINDOW POSITION SWITCH
DUPLEX 5-15R SWITCHED RECEPTACLE
QUADPLEX 5-20R SWITCHED RECEPTACLE
TEL
TV
SUITE TELEPHONE TERMINATION BOX
SUITE CATV TERMINATION BOX
LINE VOLTAGE SWITCH WITH PASSIVE INFRARED VACANCY SENSOR
LINE VOLTAGE SWITCH WITH DUAL TECHNOLOGY VACANCY SENSOR
LOW VOLTAGE SWITCH WITH PASSIVE INFRARED VACANCY SENSOR
LOW VOLTAGE SWITCH WITH DUAL TECHNOLOGY VACANCY SENSOR
VDT
VPIR
VPIR
VDT
S
RNG RANGE
WS WASHER
DT DUAL TECHNOLOGY OCCUPANCY SENSOR
DY DRYER
IR INFRARED OCCUPANCY SENSOR
SWD STACKED WASHER/DRYER
#° OCCUPANCY OR MOTION SENSOR BEAM SPREAD ANGLE
TYPICAL DELTA-WYE ISOLATION TRANSFORMER
OWNER POWER METER
##DUPLEX 5-20R SWITCHED RECEPTACLE
QUADPLEX 5-15R RECEPTACLE
QUADPLEX 5-15R SWITCHED RECEPTACLE
DIRECT POWER CONNECTION TO EQUIPMENT TERMINAL BOX
DUPLEX 5-15R RECEPTACLE WITH TWO USB CHARGING PORTS2 USB
4 USB DUPLEX 5-15R RECEPTACLE WITH FOUR USB CHARGING PORTS
HD HAND DRYER
FHD FAUCET / HAND DRYER COMBINATION
MP
VC
WIRELESS CONTROL
GFI
20A
20A
#
#
#
C
C
S
C
B
##
##
#
F
F
F
F
F
A
F
F
F
F
F
F
F
SA
CO
CO
H
S
DA
CACF
FACP
FAA
M
PS
FS
TS
DA
ELR
CM
MM
ISO
PTZ
PTZ
CR
CR K
K IA
KO
RE
P
RE
M
G
S
ML
ES
DP
WP
M
IAD
IAC
PWD
PWC
ET
RR REMOVE AND RE-INSTALL DEVICE IN ORIGINAL POSITION
MICROPHONE OUTLETM
Co
py
rig
ht
Re
serv
ed
Da
te
Sca
le
Dra
win
g
Pro
ject
Pro
ject
Nu
mb
er
Sh
ee
t N
um
be
r
Th
is p
lan
an
d d
esi
gn
are
th
e e
xclu
siv
e p
rop
ert
y o
f
Th
ink
spa
ce A
rch
ite
ctu
re,
Pla
nn
ing
, In
teri
or
De
sig
n
(Th
ink
spa
ce)
an
d c
an
no
t b
e u
sed
or
rep
rod
uce
d w
ith
ou
t
wri
tte
n c
on
sen
t o
f T
hin
ksp
ace
. T
his
off
ice
sh
all
be
in
form
ed
of
an
y v
ari
ati
on
s fr
om
th
e i
nfo
rma
tio
n s
ho
wn
on
th
is
dra
win
g.
Do
no
t sc
ale
dra
win
gs.
Th
ink
spa
ce,
a p
art
ne
rsh
ip o
f:
Ro
n H
off
art
, A
rch
ite
ct A
IBC
M
ark
Ma
thia
sen
, A
rch
ite
ct A
IBC
To
dd
Du
st,
Arc
hit
ect
AIB
C
H
en
k K
am
pm
an
, A
rch
ite
ct A
IBC
Issu
ed
Fo
r
PRINTED:
Da
te
Re
vis
ion
s
No
.D
ate
De
scri
pti
on
200,
16
28 D
icks
on
Av
enu
e
Kel
ow
na
BC
V1
Y 9
X1
Ph
on
e:
(25
0) 8
60-
2257
Fax
:
(
250
) 8
60-2
523
ww
w.c
ima
.ca
11/15/2018 2:50:12 PM
K0
00
29
3A
FN
HA
PR
INC
E G
EO
RG
E O
FF
ICE
RE
NO
.
SY
MB
OL
LEG
EN
D
E-00
0
20
18
-11
-01
NT
S
20
0-1
77
VIC
TO
RIA
ST
RE
ET
PR
INC
E G
EO
RG
E,
B.C
.
V2
L 5
R8
FIR
ST
NA
TIO
NS
HE
ALT
H
AU
TH
OR
ITY
06
/06
/17
DRAWING LIST
SHEET NUMBER SHEET NAME
E-000 SYMBOL LEGEND
E-100 EXISTING ELECTRICAL PLAN
E-200 ELECTRICAL RENOVATION PLAN
E-300 SCHEDULES
E-301 SCHEDULES
E-400 SPECIFICATIONS
12
01
8-1
0-0
5IS
SU
ED
FO
R C
OO
RD
INA
TIO
N
22
01
8-1
1-0
1IS
SU
ED
FO
R 9
5%
RE
VIE
W
32
01
8-1
1-0
9IS
SU
ED
FO
R B
UIL
DIN
G P
ER
MIT
42
01
8-1
1-1
5IS
SU
ED
FO
R B
I D
53 421
A
B
C
1 2 5
D
3 4
E
273
OPEN OFFICE
220
SUITE
275
OFFICE
272
OFFICE
271
LAN
276
OPEN OFFICE
270
RECEPTION
285
OFFICE
286
OFFICE
287
OFFICE
288
OPEN OFFICE
284
OFFICE
278
COPY
260
OPEN OFFICE
271
SERVER
250
SUITE
FEMALE W.C.
ST.
274
LAB
277
MEETING
279
OFFICE
280
OPEN OFFICE283
OFFICE
282
OFFICE281
OFFICE
MALE W.C.
200
STAIRS
ST.
201
CORRIDOR
s
ss
s s
s
s
s s
s
s
s
s
ss
ss
s s
s
s
s
s s
sss
s s s s s s
ss
s s s ss
s s
53 421
A
B
C
1 2 5
D
3 4
E
273
OPEN OFFICE
220
SUITE
275
OFFICE
272
OFFICE
271
LAN
276
OPEN OFFICE
270
RECEPTION
285
OFFICE
286
OFFICE
287
OFFICE
288
OPEN OFFICE
284
OFFICE
278
COPY
260
OPEN OFFICE
271
SERVER
250
SUITE
FEMALE W.C.
ST.
274
LAB
277
MEETING
279
OFFICE
280
OPEN OFFICE283
OFFICE
282
OFFICE281
OFFICE
MALE W.C.
200
STAIRS
ST.
201
CORRIDOR
ST.
GENERAL NOTES
DRAWING NOTES
1 SECURITY CCTV MONITOR.
LUMINAIRE WAS NOT OPERATIONAL DURING SITE INSPECTION.
REMOVE BOARD AND RECEPTACLES AND MOVE ALL EQUIPMENT TO LAN
ROOM 271. ALL DATA OUTLETS AND CABLING EAST OF GRIDLINE 3 TO BE
REMOVED. NEW OUTLETS AND CABLING TO BE WIRED TO LAN ROOM 271 ON EXISTING FREE-STANDING DATA RACK. PROVIDE NEW PATCH PANELS AS
REQUIRED.
LUMINAIRE TO BE RE-USED, RE-BALLASTED WITH NEW PROGRAM START BALLAST AND RE-LAMPED.
1. ALL EXISTING 2'x4' FIXTURES ARE RECESSED, 2F32T8, 3500K WITH AIR SLOTS.
2. EXISTING RECESSED POT LIGHTS LABELED WITH 'a' ARE MR16 LED. REMAINING EXISTING POT LIGHTS ARE 8" WITH SINGLE QUAD LAMP.
3. EXISTING CONTROLS ARE DOUGLAS LV CONTROLS
4. ALL JUNCTION BOXES ARE IN-WALL COVERED WITH BLANK DECORA COVER PLATE
UNLESS OTHERWISE NOTED.
5. ALL DEVICES SHALL REMAIN IN PLACE UNLESS EXPLICITLY NOTED OTHERWISE.
6. ALL LUMINAIRES TO BE REMOVED SHALL BE INVENTORIED, TAGGED AND HANDED
OVER TO OWNER.
7. ALL DEVICES SHOWN TO BE REMOVED SHALL BE COMPLETELY REMOVED FROM
SITE BY THE CONTRACTOR IN A SUSTAINABLE MANNER INCLUDING WIRING BACK
TO ORIGIN. PROVIDE COVERPLATES FOR UNUSED OUTLET BOXES.
8. EXTEND WIRING AS REQUIRED FOR DEVICES TO BE RELOCATED.
2
3
4
D
D
D
aa
a a a a
a
a
a
a
a
2
EXRLRLRLRLRL
RLRLRL
RL
RL
RE RE RE RE
RERE
RERE
RE
RE
RE
RE RE
RE RE RE RE
RE
RE RE RE RE RE
RE
EX
RE
RERE
RERE
REEX
RERE
RERE
EX
RERE
RE
EX
EXEX
EX
RERE
RE
RE RE
RE
RLRL
RL
EX
RL RE
RE
RE
RE RE
RERERE
EX
RL
EX
EX
RL
EX
EX
EX
RL
RL
EX
EX
EX
RL
RL
RLEX
RERERE
RE
RL
RL
RL
RL
RE
RE
RERERERE
RE
RE
RE
RE
RERE
RE
EX
RE
EX EX
EX EX
EX EX EX
EX EX
EX
EX
RE
EX
EX
EX EX EX
RE
RE
EX
EX
EX
EX
EX
EX
EX
EXEX
EX
EX
EX
EX EX
EX
EX
EX
DASHED LINE DENOTES
AREA OF RENOVATION
4 4 4
444
4
RL4
EXEX4
EXEXEX
EXEXEX
RE
4
4
4
4
4
4
4
4
4 4
4
EX
4
RE
RE
RERE
RL4
EX
EX
EXEX
EXEX
EX
EX
EX
4
EX
EX
4
4
RE
RE
3
3
2
2
2C-49
HC2-1
HC2-4
2C-63
HC2-32
2
2C-63
2C-47
2CA-11
2CA-6 2CA-16
2CA-142CA-5
3
HC2-11
32C-47
CISCO WIFI MOUNTED ON
CEILING ANDWIRED DOWN WALL. REMOVE
OUTLET AND WIRING AND
REPLACE WITH NEW CEILING OUTLET.
HC2-10
3HC2-9
4HC2-142C-45
2HC2-19 2C-43
3 HC2-16
2C-61
3 HC2-17
2C-61
M
J J
2C-53
J
2C-51
2C-15
2C-13
2C-13
DATA
RACK
2C-53
J2C-51
2C-38
2C-30
2C-53
J
2
2C-30
2C-532
2C-51
J
2C-19
2C-192
J
2C-51
2C-40
2C-36 2C-212
2C-15
2C-42
2C-28
2C-30
2C-301
2C-341
2C-51
2
2C-51
12C-532C-212C-19
1
2C-421
1 2C-15
M
TEL/DATA
BOARD
PANEL A 2A-16
RE
A-18
RE
GFI
2C-19
A-4
A-32C-21
2C-19
2CA-35
2CA-352 2C-55
2C-55
JA-8A-6A-6
3
J
J
EX
2CA-38
2CA-38
2CA-38
JJ
2CA-34
J
2CA-362
2CA-40
1
2CA-222CA-28
JC2
2CA-28
OS
JC1
2CA-28
2CA-55
J2
2CA-282CA-28
JJ
2CA-57
2CA-402
J
+914mm
AFF
J
2CA-40
+914mm
AFF
J
2C-33
1
3
2C-31
2C-35
HC2-30
2
2C-31
2C-35
D-33
D-17
3
HC2-26
2CA-422C-70
1
D-9
2C-70
2C-222C-22
F
2C-33
2C-24
2
HC2-28
2C-33
3
HC2-25
3
HC2-24
2C-59
J
J
C
2C-37
3HC2-20
2
2C-37
J
2C-59
2C-59
J
2C-41
J
F
FDW2C-68
2C-31K 2C-68 CR
RE
RE
4E-100
3E-100
J
D45
RP
GFIGFIA-9 A-7
30A TWIST-LOCK
A-17
J JWALL MOUNTED TV
IN-WALL CABLING FROM
LOW LEVEL TO BEHIND TV TO BE REMOVED
J
IN-WALL CABLING
TO MONITOR
RE
V6D5
FOB ACCESS
ES
ES
SHUB-M
HOLD-UP BUTTON
CISCO WIFI MOUNTED ON CEILING AND
WIRED DOWN WALL. REMOVE OUTLET
AND WIRING AND REPLACE WITH NEW CEILING OUTLET.
EX
EXEX
RP
EX
EXEX
EXEXRP
EXRP EXEX RP
RP
EX
EXRP
EX
EX
RP
EX EX
EX RP
EX
RERE
RE
RP
EX
EX
RE
RERERE
C
RL
RE
RERE
RE
EX
RERE RE
RERE
RE
RE
RE
RE
RE
RE
RERE
RE
RE
RERERERE
RERE
EX
RE
EX
RERE
RE RE
RERERE
RERE RE
RERE
EX
EX
RP
RE RE
RE
RE
EX
EX
RPRE
RE
RERE
EXEXEX
RP
RERERERERERE
RP
EXEX
EX
RP
RERE
EX
RP
EX
RR
EXEX
EX
EX
RP
EX
EX
3
RPRP
EX
EX
EX
EXEX
EX
EXEXEX
EX
EX
EX
EX
EX
EXRE
RP
EX
EX EX
RE
EXRP
EX
EX
EX
RP
RE
RE
EX
EX
RERE
REEX
RE
EX
RE
RL
EX
EX
RE
RE RE
EX
EX EX
EX
EXEXEX
EX
RP
EX EX
EX
EX
EX
EX
RP
EX
EX
EX EX
EXEX
RP
EX
EX
EXEX
RL
EX
EXEXDP
CR
EX
EX
DATA RACKS
EX
EX
EXINTRUSION ALARM
PANEL
CCTV DVR
3
DASHED LINE DENOTES
AREA OF RENOVATION
RE RE
EX
EXEX
EX
1
F FFF
EXEX EXEX
PANEL 6C
PANEL 2C-1
PANEL 2C-2
LVRC
PANEL 2CA
KEYSCAN ACCESS
CONTROL
KANTECH KT-300
ABOVE DOOR
ELECTRICAL ROOM TEL. ROOM
PANEL 6A
PANEL 6D2
PANEL 6E
PANEL 2A
PANEL 2K
T3
300 KVA
METER 1
PANEL 2D1
EF-1 TO EF-5 HOA'S AND JUNCTION BOX
MOUNTED ABOVE CAPACITOR BANK
POWER FACTOR
CORRECTION CAPACITORS
PANEL 2M
T2
75 KVA
PANEL 6M
T1
75 KVA
MC1
EXTERIOR LIGHTING
HOA'S
METER 2
MOUNTED BELOW PANEL
KANTECH
KT-300
FACP
DISTRIBUTION
SECTION
C/T
CABINET
600V, 3Ø, 4W
MAIN BREAKER
PULL
SECTION
BC HYDRO
METER
TEL. BOX
TEL. CABINET (x2)
CIRCA TELECOM
CABINETS (x9)
TEL/DATA BOARD
N
Co
py
rig
ht
Re
serv
ed
Da
te
Sca
le
Dra
win
g
Pro
ject
Pro
ject
Nu
mb
er
Sh
ee
t N
um
be
r
Th
is p
lan
an
d d
esi
gn
are
th
e e
xclu
siv
e p
rop
ert
y o
f
Th
ink
spa
ce A
rch
ite
ctu
re,
Pla
nn
ing
, In
teri
or
De
sig
n
(Th
ink
spa
ce)
an
d c
an
no
t b
e u
sed
or
rep
rod
uce
d w
ith
ou
t
wri
tte
n c
on
sen
t o
f T
hin
ksp
ace
. T
his
off
ice
sh
all
be
in
form
ed
of
an
y v
ari
ati
on
s fr
om
th
e i
nfo
rma
tio
n s
ho
wn
on
th
is
dra
win
g.
Do
no
t sc
ale
dra
win
gs.
Th
ink
spa
ce,
a p
art
ne
rsh
ip o
f:
Ro
n H
off
art
, A
rch
ite
ct A
IBC
M
ark
Ma
thia
sen
, A
rch
ite
ct A
IBC
To
dd
Du
st,
Arc
hit
ect
AIB
C
H
en
k K
am
pm
an
, A
rch
ite
ct A
IBC
Issu
ed
Fo
r
PRINTED:
Da
te
Re
vis
ion
s
No
.D
ate
De
scri
pti
on
200,
16
28 D
icks
on
Av
enu
e
Kel
ow
na
BC
V1
Y 9
X1
Ph
on
e:
(25
0) 8
60-
2257
Fax
:
(
250
) 8
60-2
523
ww
w.c
ima
.ca
11/15/2018 2:50:13 PM
K0
00
29
3A
FN
HA
PR
INC
E G
EO
RG
E O
FF
ICE
RE
NO
.
EX
IST
ING
ELE
CT
RIC
AL
PLA
N
E-10
0
20
18
-11
-01
As
ind
ica
ted
20
0-1
77
VIC
TO
RIA
ST
RE
ET
PR
INC
E G
EO
RG
E,
B.C
.
V2
L 5
R8
FIR
ST
NA
TIO
NS
HE
ALT
H
AU
TH
OR
ITY
09
/05
/18
1 : 100E-100
2 EXISTING LIGHTING LAYOUT 1 : 100E-100
1 EXISTING ELECTRICAL LAYOUT
1 : 50E-100
3EXISTING POWER LAYOUTOFFICE LEVEL ELECTRICAL ROOM
NTSE-100
5 EXISTING P1 ELECTRICAL ROOM 1 : 50E-100
4EXISTING POWER LAYOUTOFFICE LEVEL TEL. ROOM
12
01
8-1
0-0
5IS
SU
ED
FO
R C
OO
RD
INA
TIO
N
22
01
8-1
1-0
1IS
SU
ED
FO
R 9
5%
RE
VIE
W
32
01
8-1
1-0
9IS
SU
ED
FO
R B
UIL
DIN
G P
ER
MIT
42
01
8-1
1-1
5IS
SU
ED
FO
R B
I D
RE
RE
219
OFFICE
218
OFFICE
215
OFFICE
217
OFFICE
216
OFFICE214
OFFICE
212
OFFICE
210
COPY
209
MEETING
207
OPEN OFFICE
204
OFFICE
211
OFFICE
208
KITCHEN
201
LAB
202
BREAK RM
203
OPEN OFFICE
205
TEL. RM
206
LAN.
213
OFFICE
220
RECEPTION
221
BOARDROOM
222
TEL. RM
223
OFFICE
224
OPEN OFFICE
225
I.T.226
OFFICE
227
SHARED OFFICE
228
TEL. RM
230
NURSE ST.229
SEC. ST.
231
SHIPPING
207
209
212216
217
OFFICE
210
OFFICE
3
3
54321
E
D
C
B
A
FEMALE W.C. MALE W.C.
219
OFFICE
218
OFFICE
215
OFFICE
217
OFFICE
216
OFFICE214
OFFICE
212
OFFICE
210
COPY
209
MEETING
207
OPEN OFFICE
204
OFFICE
211
OFFICE
208
KITCHEN
201
LAB
202
BREAK RM
203
OPEN OFFICE
205
TEL. RM
206
LAN.
213
OFFICE
220
RECEPTION
221
BOARDROOM
222
TEL. RM
223
OFFICE
224
OPEN OFFICE
225
I.T.226
OFFICE
227
SHARED OFFICE
228
TEL. RM
230
NURSE ST.229
SEC. ST.
231
SHIPPING
207
209
212216
217
OFFICE
210
OFFICE
3
3
54321
E
D
C
B
A
FEMALE W.C. MALE W.C.
D
OS
OS
ER ER
ERER
ER
ER
ER
EX
ER
ER
EX
EX
EX
OS
OS
EX
EX
EX
EXEX
EX
EX
EXEX
EX
EX
EX
EX
EX
EX
EX EX
EX EX
EX EX
EX
EX
EX
EX
EX
EX
EX
EX EX
EX
EXEX
EX
EX
ER
3
X1
3
EX
EX
X1
D
OS
EXOS
ER
3
D3
U/C LED STRIP LIGHT
(TYPICAL OF 2 SECTIONS)
ER
OS
OS
ER
OS OS
3
X1
D1 D1 D1 D1
EXOS
OS
EX
EXER
ER
OS
OS OS
X1
D1 D1
3
DS
OS
D2
OS
OS
D2
OSER
RH1
OS
OS
DS
OS
ERD1
ER
EX
X1
X1
3
EX
X1
EX EX
OS
OS
DS
33
D3 U/C LED STRIP LIGHT
(TYPICAL)
3
DOS
OS
3
OSDS
OS
DS
RH1
OS
OS
3 3 OS
3D X1
X1
RH1
P2
DASHED LINE DENOTES
AREA OF RENOVATION
EX
EX EXEX
EX EXEX
ER
ER
ER
EX EX
EX
EX
EX
EX
EX
EX
EX
EX
ER
ER
ER
ER
ER
ER
ER
ROPELIGHT. U/C
POWER SUPPLY TO
BE MOUNTED WITHIN MILLWORK.
T2
T1
D2
ER
OS
D1 D1
D1D1
ER
ER
ER
ER
ER
ER
ER
EX
EXISTING 347V LIGHTING CIRCUITS TO
BE RE-USED FOR NEW LAYOUTS. CONTRACTOR TO RE-WIRE LIGHTING
POWER AND CONTROLS TO SUIT NEW
DESIGN SHOWN. CONNECT EXIT LIGHTS
TO EXISTING EXIT LIGHT CIRCUIT.
P2
P2P1
X1
D4
DDD
RH1
RH1
RH1
EX
EX
ER
ER
ER ER
ER
DS
EX
EX EX
D1
D1
D1
D1
D1 D1
D1
D1
D1
D1L1
L1
L1
L1
ER
3
3
2
2
2C-49
HC2-1
HC2-4
HC2-32
2
2C-63
2C-47
GFI
2CA-11
2CA-6 2CA-16
2CA-14
2CA-5
3
HC2-11
32C-47
HC2-10
3HC2-9
4
3 HC2-16
2C-61
3 HC2-17
2C-61
2C-53 2C-532C-53
2
2C-51
2C-51
2C-51
2C-51
PANEL A
2
2CA-35
2CA-352 2C-55
2C-55
EX
2CA-38
2CA-38
2CA-382CA-40
1
2CA-22 2CA-28C2
2CA-28
C1
2CA-28
2CA-55
2
2CA-282CA-28
2CA-57
2CA-402
2CA-40
+914mm
AFF
2C-33
1
2C-31
2C-352
2C-31
2C-35
D-33
D-17
3
HC2-26
2CA-422C-70
1
D-9
2C-70
2C-222C-22
F
2C-33
2C-24
2C-33
3
HC2-25
3
HC2-24
2C-59
C
2C-37
3HC2-20
2C-59
2C-59
F
FDW
CRRE
D45
RP
J
IN-WALL CABLING
TO MONITOR
FOB ACCESSES
SHUB-M
HOLD-UP BUTTON
EX
EXEX
EX
EXEX
EXEX
EXEXEX
EX
EX
EX
EX
EX EX
EX
EX
EX
EXEX
EX
EX
EX
EX
EX
EX
EXEX
EX
EX
EX
EXEX
EX
RR
EXEX
EX
EXEX
EX
3
EX
EX
EX
EXEX
EX
EXEXEX
EX
EX
EX
EXEX
EX
EX
EX EXEX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX EX
EX
EXEXEX
EX
EX EX
EX
EX
EX
EX
EX
EX
EX EX
EXEX EX
EX
EX
EX
EXEX
3
2
2
2
ESDP
CR ESDP
CR
2
ESCR
3 2
ESDP
CRK
3 2
2
4
2
4
2
2
2
EX
2
2
3
4
2
4
GFI GFIJ
MW
DP
KER
CR RE
ESDP
K
CER
+2300 AFF
GFIGFI
M
ER
DP
2 2H
H H
+254 AFF
A-33
K
CRRE
ESDP
1+1500 AFF
CR
ESDP1
+1500 AFF
M
EX
EXDATA RACKS
EX
EXINTRUSION ALARM PANEL
CCTV DVR
EX
DASHED LINE DENOTES AREA OF RENOVATION
RE
ES
EX
DP
CREX
EXEX
A-25
+1575 AFF
M
M
1
1
PROVIDE 25mmC TO
ARLINGTON BOX ABOVE.
1
PROVIDE 2x25mmC
TO T-BAR CEILING SPACE
2
3
A-19 A-19
A-27
2C-59
A-21
A-29
A-31
2CA-35
A-35
2C-28
2C-30 2C-402C-38
2C-30 2C-40
2C-38
2C-28
2C-362C-36
2C-36
2C-212C-21
2C-19
2C-34 2C-34
2C-34
2C-19
2C-15 2C-15
F2C-13
2C-19
2C-36
A-23
A-23
A-33 A-33
3
3
3A-35
A-35
A-35
FLOOR
MOUNTED (TYP)
32C-59
5
A-37
F
4
4
4
4
AC-2
CU-1 CU-2
WPWP
GROUND LEVEL
ROUTE WIRING WITHIN BUILDING
TO LANDLORD'S SATISFACTION
AC-1
EF-1
T
DETAIL NOTES
1. REFER TO ARCHITECTURAL DOOR SCHEDULE AND PLANS FOR DOOR DETAILS.
2. COORDINATE THE SUPPLY AND INSTALL OF ALL EQUIPMENT WITH THE DOOR/HARDWARE INSTALLER TO ENSURE A COMPLETE WORKING SYSTEM.
3. DRILL DOOR FRAME TO MATCH DOOR POSITION SWITCHES.
4. ALL CONDUIT SHALL BE 20mm EMT UNLESS OTHERWISE SHOWN.
5. REFER TO ELECTRICAL PLAN DRAWING FOR DEVICE LOCATIONS.
6. ALL JUNCTION BOXES SHALL BE ON THE SECURE SIDE IN THE ACCESSIBLE CEILING SPACE.
IF NO ACCESSIBLE CEILING SPACE, MOUNT JUNCTION BOXES ABOVE DOOR CENTERED AND
ALIGNED WITH EACH OTHER AND PROVIDE STAINLESS STEEL COVERPLATES.
7. RACEWAY SYSTEM TO BE CONCEALED WHERE POSSIBLE. WHERE CONCEALMENT IS NOT
POSSIBLE, PROVIDE A SURFACE MOUNTED RACEWAY SYSTEM ON THE SECURE SIDE.
8. PROVIDE FIRE GRADE PLYWOOD BACKING AND ROCKETFISH FULL MOTION TV WALL
MOUNTS SIZED APPROPRIATELY FOR THE TVS.
9. CONTRACTOR TO INSTALL ACCESS POINTS DEVICES SUPPLIED BY FNHA AND SECURE TO CEILING.
STUB INTO FRAME FOR DOOR
RELEASE WHERE SHOWN
STUB CONDUIT INTO DOOR
FRAME FOR DOOR POSITION SWITCH
150mm x 150mm ACCESS
CONTROL JUNCTION BOX ON SECURE SIDE NEAR CEILING
PROXIMITY FOB (NIC)
ON NON-SECURE SIDE
14
00
mm
25mm EMT TO SECOND ACCESS CONTROL JUNCTION
BOX. SECOND ACCESS CONTROL JUNCTION BOX TO RUN 25mm EMT TO DOOR CONTROLLER.
12m
m E
MT
12m
m E
MT
20m
m E
MT
20mm EMT
MAG-LOCK
BY OTHERS
150mm x 150mm 120V JUNCTION
BOX ON SECURE SIDE NEAR CEILING. CIRCUIT A-41.
20mm CONDUIT BETWEEN
JUNCTION BOXES
DRAWING NOTES
1 SECURITY CCTV MONITOR.
MOUNT IN RECESSED ARLINGTON OUTLET BOX BEHIND TV. 70" TV SUPPLIED
BY OTHERS TO BE CENTERED AT +2032mm (80") AFF.
MOUNT IN RECESSED ARLINGTON BOX +25mm ABOVE SHELF. SHELF MOUNTED 330mm (13") BELOW BOTTOM OF TV.
PROVIDE POKETHROUGH RECESSED FLOOR DEVICE FOR POWER AND DATA EQUAL TO LEGRAND EVOLUTION SERIES WITH CUSTOM FINISH. CONTRACTOR
SHALL X-RAY EACH LOCATION AND RETAIN THE LANDLORD'S STRUCTURAL
ENGINEER TO REVIEW AND APPROVE THE PENETRATION IN WRITING PRIOR
TO PERFORMING THE WORK. COORDINATE WITH LANDLORD FOR WIRING WITHIN TENANT SPACE BELOW.
2
3
4
CASEGOOD/STAND-ALONE WORKSTATION NOTES
POWER
1. ALL POWER RECEPTACLES AND DATA OUTLETS FOR CASEGOOD/STAND-ALONE WORKSTATIONS SHALL BE PROVIDED ALONG THE NEAREST ADJACENT WALL.
SYSTEMS/MODULAR WORKSTATION NOTES
POWER
1. WHERE SYSTEMS/MODULAR FURNITURE IS USED (REFER TO ARCHITECTURAL
DRAWINGS FOR LOCATIONS), THE CONTRACTOR SHALL PROVIDE POWER TO THE NEAREST WALL AND TERMINATE FURNITURE WHIPS BY METHOD OF HARD
WIRING.
2. ELECTRICAL CONTRACTOR TO BALANCE AND DISTRIBUTE THE ELECTRICAL
LOADS OF WORKSTATION PODS EVENLY AMONGST CIRCUITS (EX. POD OF 6
WORKSTATIONS, 2 DEDICATED CIRCUITS, 3 PODS CONNECTED TO EACH
CIRCUIT).
DATA
1. WHERE SYSTEMS/MODULAR FURNITURE IS USED (REFER TO ARCHITECTURAL
DRAWINGS FOR LOCATIONS), THE CONTRACTOR SHALL PROVIDE AND INSTALL USING COMPATIBLE VOICE DATA MODULES (VDM 2100) AND TERMINATE
WORKSTATION DATA OUTLETS WITH THE VDM.
2. VDM CAN BE FOUND WITHIN THE SYSTEMS/MODULAR FURNITURE ACCESS PANELS OR WILL BE PROVIDED BY FNHA.
DATA CABLES TO
LAN ROOM
LABELLED DATA JACKS
VDM 2100 MOUNTED IN
SYSTEMS/MODULAR
WORKSTATION ACCESS PANELS
CROSS-CONNECT DATA CABLE TO
DEVICES SUPPLIED BY OTHERS AND RUN IN FURNITURE CHASE
N
Co
py
rig
ht
Re
serv
ed
Da
te
Sca
le
Dra
win
g
Pro
ject
Pro
ject
Nu
mb
er
Sh
ee
t N
um
be
r
Th
is p
lan
an
d d
esi
gn
are
th
e e
xclu
siv
e p
rop
ert
y o
f
Th
ink
spa
ce A
rch
ite
ctu
re,
Pla
nn
ing
, In
teri
or
De
sig
n
(Th
ink
spa
ce)
an
d c
an
no
t b
e u
sed
or
rep
rod
uce
d w
ith
ou
t
wri
tte
n c
on
sen
t o
f T
hin
ksp
ace
. T
his
off
ice
sh
all
be
in
form
ed
of
an
y v
ari
ati
on
s fr
om
th
e i
nfo
rma
tio
n s
ho
wn
on
th
is
dra
win
g.
Do
no
t sc
ale
dra
win
gs.
Th
ink
spa
ce,
a p
art
ne
rsh
ip o
f:
Ro
n H
off
art
, A
rch
ite
ct A
IBC
M
ark
Ma
thia
sen
, A
rch
ite
ct A
IBC
To
dd
Du
st,
Arc
hit
ect
AIB
C
H
en
k K
am
pm
an
, A
rch
ite
ct A
IBC
Issu
ed
Fo
r
PRINTED:
Da
te
Re
vis
ion
s
No
.D
ate
De
scri
pti
on
200,
16
28 D
icks
on
Av
enu
e
Kel
ow
na
BC
V1
Y 9
X1
Ph
on
e:
(25
0) 8
60-
2257
Fax
:
(
250
) 8
60-2
523
ww
w.c
ima
.ca
11/15/2018 2:50:13 PM
K0
00
29
3A
FN
HA
PR
INC
E G
EO
RG
E O
FF
ICE
RE
NO
.
ELE
CT
RIC
AL
RE
NO
VA
TIO
N P
LAN
E-20
0
20
18
-11
-01
As
ind
ica
ted
20
0-1
77
VIC
TO
RIA
ST
RE
ET
PR
INC
E G
EO
RG
E,
B.C
.
V2
L 5
R8
FIR
ST
NA
TIO
NS
HE
ALT
H
AU
TH
OR
ITY
09
/25
/18
1 : 100E-200
2 RENOVATED LIGHTING LAYOUT 1 : 100E-200
1 RENOVATED ELECTRICAL LAYOUT
NTSE-200
3 ACCESS CONTROL SINGLE DOORNTSE-200
4 WORKSTATION VDM DETAIL
12
01
8-1
0-0
5IS
SU
ED
FO
R C
OO
RD
INA
TIO
N
22
01
8-1
1-0
1IS
SU
ED
FO
R 9
5%
RE
VIE
W
32
01
8-1
1-0
9IS
SU
ED
FO
R B
UIL
DIN
G P
ER
MIT
42
01
8-1
1-1
5IS
SU
ED
FO
R B
I D
Co
py
rig
ht
Re
serv
ed
Da
te
Sca
le
Dra
win
g
Pro
ject
Pro
ject
Nu
mb
er
Sh
ee
t N
um
be
r
Th
is p
lan
an
d d
esi
gn
are
th
e e
xclu
siv
e p
rop
ert
y o
f
Th
ink
spa
ce A
rch
ite
ctu
re,
Pla
nn
ing
, In
teri
or
De
sig
n
(Th
ink
spa
ce)
an
d c
an
no
t b
e u
sed
or
rep
rod
uce
d w
ith
ou
t
wri
tte
n c
on
sen
t o
f T
hin
ksp
ace
. T
his
off
ice
sh
all
be
in
form
ed
of
an
y v
ari
ati
on
s fr
om
th
e i
nfo
rma
tio
n s
ho
wn
on
th
is
dra
win
g.
Do
no
t sc
ale
dra
win
gs.
Th
ink
spa
ce,
a p
art
ne
rsh
ip o
f:
Ro
n H
off
art
, A
rch
ite
ct A
IBC
M
ark
Ma
thia
sen
, A
rch
ite
ct A
IBC
To
dd
Du
st,
Arc
hit
ect
AIB
C
H
en
k K
am
pm
an
, A
rch
ite
ct A
IBC
Issu
ed
Fo
r
PRINTED:
Da
te
Re
vis
ion
s
No
.D
ate
De
scri
pti
on
200,
16
28 D
icks
on
Av
enu
e
Kel
ow
na
BC
V1
Y 9
X1
Ph
on
e:
(25
0) 8
60-
2257
Fax
:
(
250
) 8
60-2
523
ww
w.c
ima
.ca
11/15/2018 2:50:13 PM
K0
00
29
3A
FN
HA
PR
INC
E G
EO
RG
E O
FF
ICE
RE
NO
.
SC
HE
DU
LES
E-30
0
20
18
-11
-01
NT
S
20
0-1
77
VIC
TO
RIA
ST
RE
ET
PR
INC
E G
EO
RG
E,
B.C
.
V2
L 5
R8
FIR
ST
NA
TIO
NS
HE
ALT
H
AU
TH
OR
ITY
10
/05
/18
12
01
8-1
0-0
5IS
SU
ED
FO
R C
OO
RD
INA
TIO
N
22
01
8-1
1-0
1IS
SU
ED
FO
R 9
5%
RE
VIE
W
32
01
8-1
1-0
9IS
SU
ED
FO
R B
UIL
DIN
G P
ER
MIT
42
01
8-1
1-1
5IS
SU
ED
FO
R B
I D
PANEL 2C-1 (CCT 1-42)
120/208 VAC
225
SECOND FLOOR ELECTRICAL ROOM
CUTLER-HAMMER POW-R-LINE C PRL1
15
13
19
17
5
7
9
1
LOADCCT.
No.
VOLTAGE
BUS AMPACITY
NAMEPLATE
BRKRBRKR
AMPS
TYPE
LOCATION
16
20
18
14
6
10
8
2
No.
CCT.LOAD
CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT.
IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN
ON THE DRAWING THE CONTRACTOR SHALL MAKEADJUSTMENTS TO SUIT THE INTENT OF THE WORK.
31
35
33
39
37
23
29
27
21
38
42
40
34
36
32
30
22
24
3
11
25
41
4
12
26
28
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
RECEPTACLES #230
RECEPTACLES #230 1P-15A
1P-15A
1P-15A
1P-15A
DDC CONTROLS WEST
HWT #260 1P-15A
1P-20A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
LAN ROOM #250
LAN ROOM #260
1P-15A
1P-15A
RECEPTACLES #220
PHOTOCOPIER RECEPTACLE #220
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
RECEPTACLES #230
RECEPTACLES #250 & 260
PHOTOCOPIER & RECEPTACLES #230
RECEPTACLES #250 & 260
RECEPTACLES #260
RECEPTACLES #260
RECEPTACLES #260
RECEPTACLES #260
RECEPTACLES #200
RECEPTACLES #200
RECEPTACLES #200
RECEPTACLES #200 & FRIDGE
MICROWAVE #200
#200 KITCHEN COUNTER RECEPTACLE
DDC CONTROLS NORTH
DDC CONTROLS EAST
DDC CONTROLS SOUTH
RECEPTACLES #200
RECEPTACLES #200
RECEPTACLES #250
RECEPTACLES #250
RECEPTACLES #250
RECEPTACLES #250
RECEPTACLES #250
RECEPTACLES #250
RECEPTACLES #250 FOR FRIDGE
COUNTER PLUG #250 KITCHEN
RECEPTACLES #200
VAV 27-2 & 28-2
VAV 25-2 & 26-2 & 32-2
VAV 23-2 & 24-2 & 31-2
VAV 21-2 & 22-2
VAV 17-2 & 18-2
VAV 19-2 & 20-2 & 29 30-2
PANEL 2C-2 (CCT 43-84)
120/208 VAC
225
SECOND FLOOR ELECTRICAL ROOM
CUTLER-HAMMER POW-R-LINE C PRL1
57
55
59
47
49
51
43
LOADCCT.
No.
VOLTAGE
BUS AMPACITY
NAMEPLATE
BRKRBRKR
AMPS
TYPE
LOCATION
48
44
No.
CCT.LOAD
CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT.
IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN
ON THE DRAWING THE CONTRACTOR SHALL MAKEADJUSTMENTS TO SUIT THE INTENT OF THE WORK.
84
78
66
45
53
46
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
RECEPTACLES #200 & 220
BLANK
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
RECEPTACLES #260
RECEPTACLES #270
KITCHEN COUNTER RECEPTACLE #230
RECEPTACLES #230
MICROWAVE COUNTER RECEPTACLE #230
SERVER RECEPTACLE #230
WASHROOMS GFI RECEPTACLES
RECEPTACLES #200
HWT #220 & 200
HWT #250
PLUGS ABOVE T-BAR #250
82
80
76
74
72
70
68
64
62
60
58
56
54
52
50
83
77
65
81
79
75
73
71
69
67
63
61
SUB PANEL 2CA ELECTRICAL ROOM 2ND
FLOOR
3P
60A
3P
70A
RECEPTACLES #200
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
RECEPTACLES #200
RECEPTACLES #220 & 230
RECEPTACLES #250
RECEPTACLES #250 AND MICROWAVE
RECEPTACLES #200
RECEPTACLES #200 EAST CORNER
RECEPTACLES #200 & 220
JANITOR & ELECTRICAL ROOM RECEPTACLES
TEL CLOSET RECEPTACLES
WASHROOM ENTRANCE RECEPTACLES
RECEPTACLES #230
RECEPTACLES #230
SUB PANEL A ROOM #260
RECEPTACLES #200
RECEPTACLES #200
RECEPTACLES #200
RECEPTACLES #200
PLUGS ABOVE T-BAR #250
PLUGS ABOVE T-BAR #250
PLUGS ABOVE T-BAR #250
PLUGS ABOVE T-BAR #250
PLUGS ABOVE T-BAR #250
PLUGS ABOVE T-BAR #250
CROSSED OUT CIRCUITS ARE REMOVED AND RE-USED. REFER TO PLAN DRAWINGS FOR RE-USED CIRCUITS. REMOVE EXISTING WIRING TO CIRCUIT AND PROVIDE NEW.
PANEL 2C HAS TWO CABINETS SIDE-BY-SIDE.
1P-15A
PANEL 6C
347/600 VAC
SECOND FLOOR ELECTRICAL ROOM
CUTLER-HAMMER POW-R-LINE C PRL2
15
13
19
17
5
7
9
1
LOADCCT.
No.
VOLTAGE
BUS AMPACITY
NAMEPLATE
BRKRBRKR
AMPS
TYPE
LOCATION
16
20
18
14
6
10
8
2
No.
CCT.LOAD
CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT.
IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN
ON THE DRAWING THE CONTRACTOR SHALL MAKEADJUSTMENTS TO SUIT THE INTENT OF THE WORK.
31
35
33
39
37
23
29
27
21
38
42
40
34
36
32
30
22
24
3
11
25
41
4
12
26
28
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
2ND FLOOR OFFICE LIGHTS
1P-15A
1P-15A
1P-15A
1P-15A
2ND & 3RD FLOOR EMERG & NIGHT LIGHTS
2ND FLOOR OFFICE LIGHTS
1P-15A
2ND FLOOR CMHC OFFICE LIGHTS
2ND FLOOR OFFICE LIGHTS
BLANK
1P-15ABLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
3RD FLOOR OFFICE LIGHTS
3RD FLOOR OFFICE LIGHTS
3RD FLOOR OFFICE LIGHTS
3RD FLOOR OFFICE LIGHTS
3RD FLOOR OFFICE LIGHTS
3RD FLOOR OFFICE LIGHTS
3RD FLOOR OFFICE LIGHTS
3RD FLOOR OFFICE LIGHTS
3RD FLOOR OFFICE LIGHTS
2ND & 3RD FLOOR LOBBY LIGHTS
2ND FLOOR OFFICE LIGHTS
2ND & 3RD FLOOR WASHROOM LIGHTS
EXIT LIGHTS
PANEL 2CA
120/208 VAC
SECOND FLOOR ELECTRICAL ROOM
CUTLER-HAMMER POW-R-LINE C PRL1
15
13
19
17
5
7
9
1
LOADCCT.
No.
VOLTAGE
BUS AMPACITY
NAMEPLATE
BRKRBRKR
AMPS
TYPE
LOCATION
16
20
18
14
6
10
8
2
No.
CCT.LOAD
CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT.
IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN
ON THE DRAWING THE CONTRACTOR SHALL MAKEADJUSTMENTS TO SUIT THE INTENT OF THE WORK.
31
35
33
39
37
23
29
27
21
38
42
40
34
36
32
30
22
24
3
11
25
41
4
12
26
28
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
LAB PLUGS #220
1P-15A
PLUGS IN HEALTH CANADA (AUTOCLAVE)
1P-20A
RECEPTACLES #260
A/C LAN ROOM #200
RECEPTACLES #270
POT LIGHTS MEETING RM #200
FRIDGE & WATER COOLER IN #200
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
LAB RECEPTACLES #220
PHOTOCOPIER #200
225
2P
20A
3P
40A
2P
20A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
LAB RECEPTACLES #220
LAB RECEPTACLES #220
LAB RECEPTACLES #220
LAB RECEPTACLES #220
LAB RECEPTACLES #220
LAB RECEPTACLES #200
LAN RECEPTACLES #200
LAN RECEPTACLES #200
LAN RECEPTACLES #200
LAN RECEPTACLES #200
LAN RECEPTACLES #200
EXHAUST FAN LAB #220
RECEPTACLES #260
RECEPTACLES #260
LAB RECEPTACLES #220
LAB RECEPTACLES #220
LAB RECEPTACLES #220
LAB RECEPTACLES #220
LAB RECEPTACLES #220
LAB RECEPTACLES #220
HEALTH CANADA DISHWASHER #200
RECEPTACLES #270
RECEPTACLES #270
RECEPTACLES #270
RECEPTACLES #270
RECEPTACLES #270
RECEPTACLES #270
RECEPTACLES #270
RECEPTACLES #270
GENERAL NOTES
1. CONFIRM EXISTING AND RE-PURPOSED CIRCUITS AND PROVIDE NEW TYPEWRITTEN
PANELBOARD SCHEDULES FOR ALL PANELBOARDS. UPDATE LABELS TO NEW ROOM NUMBERING.
PANEL A
120/208 VAC
225
SERVER ROOM 271
SQUARE D QBL 442
15
13
19
17
5
7
9
1
LOADCCT.
No.
VOLTAGE
BUS AMPACITY
NAMEPLATE
BRKRBRKR
AMPS
TYPE
LOCATION
16
20
18
14
6
10
8
2
No.
CCT.LOAD
CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT.
IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN
ON THE DRAWING THE CONTRACTOR SHALL MAKEADJUSTMENTS TO SUIT THE INTENT OF THE WORK.
31
35
33
39
37
23
29
27
21
38
42
40
34
36
32
30
22
24
3
11
25
41
4
12
26
28
KITCHEN RECEPTACLES
1P-15A
1P-15A
1P-15A
1P-15A
1P-20A
1P-15A
1P-15A
1P-15A
1P-15A
EXHAUST FANS
CCT COMP ROOM GFI RECEPTACLES
CCT COMP ROOM GFI RECEPTACLES
RECEPTACLES IN #260
SPARE
CCT
CCT
FED FROM PANEL 2C CCT 74-76-78
2P
15A
1P-15A
1P-15A
1P-15A
1P-15A
KITCHEN GFI
RECEPTACLES IN #260
COMP ROOM RECEPTACLES 1P-15A1P-30A
1P-20A
1P-20A
1P-15A
1P-20A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
RECEPTACLES IN #260
RECEPTACLES IN #260
COPIER RECEPTACLE - COPY #210
RECEPTACLE - OFFICE #211
RECEPTACLES - OPEN OFFICE #224
FLOOR RECEPTACLES - BOARDROOM #221
SPARE
SPARE
SPARE
SPARE
RECEPTACLES IN #260
RECEPTACLES IN #260
RECEPTACLES IN #260
RECEPTACLES IN #260
RECEPTACLES - OPEN OFFICE #207
FRIDGE RECEPTACLE - KITCHEN #208
COUNTER RECEPTACLES - KITCHEN #208
EF-1 BOARDROOM EXHAUST
RECEPTACLES - RECEPTION
BLANK
ACCESS DOOR LOCKS
BLANK
BLANK
BLANK
MICROWAVE RECEPTACLE - KITCHEN #208
1P-15A
1P-15A
1P-20A
DISHWASHER - KITCHEN #208
1P-15A
1P-15A
1P-15A
TEL ROOM 205 A/C2P
15A
BOARDROOM 221 A/C2P
15A
PANEL 2C-1 (CCT 1-42)
120/208 VAC
225
SECOND FLOOR ELECTRICAL ROOM
CUTLER-HAMMER POW-R-LINE C PRL1
15
13
19
17
5
7
9
1
LOADCCT.
No.
VOLTAGE
BUS AMPACITY
NAMEPLATE
BRKRBRKR
AMPS
TYPE
LOCATION
16
20
18
14
6
10
8
2
No.
CCT.LOAD
CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT.
IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN
ON THE DRAWING THE CONTRACTOR SHALL MAKEADJUSTMENTS TO SUIT THE INTENT OF THE WORK.
31
35
33
39
37
23
29
27
21
38
42
40
34
36
32
30
22
24
3
11
25
41
4
12
26
28
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
RECEPTACLES #230
RECEPTACLES #230 1P-15A
1P-15A
1P-15A
1P-15A
DDC CONTROLS WEST
HWT #260 1P-15A
1P-20A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
FRIDGE RECEPTACLES - BOARDROOM #221
COUNTER RECEPTACLES - BOARDROOM #221
1P-15A
1P-15A
RECEPTACLES #220
PHOTOCOPIER RECEPTACLE #220
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-20A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
1P-15A
RECEPTACLES #230
CONV. RECEPTACLES
PHOTOCOPIER & RECEPTACLES #230
OFFICE RECEPTACLES - IT #225 & OPEN #224
RECEPTACLES #260
RECEPTACLES #260
RECEPTACLES #260
RECEPTACLES #260
RECEPTACLES #200
RECEPTACLES #200
RECEPTACLES #200
RECEPTACLES #200 & FRIDGE
MICROWAVE #200
#200 KITCHEN COUNTER RECEPTACLE
DDC CONTROLS NORTH
DDC CONTROLS EAST
DDC CONTROLS SOUTH
RECEPTACLES #200
RECEPTACLES #200
OFFICE RECEPTACLES
RECEPTACLES #250
CONV. RECEPTACLES
RECEPTACLES #200
VAV 27-2 & 28-2
VAV 25-2 & 26-2 & 32-2
VAV 23-2 & 24-2 & 31-2
VAV 21-2 & 22-2
VAV 17-2 & 18-2
VAV 19-2 & 20-2 & 29 30-2
1P-15A
OFFICE RECEPTACLES
SWITCHED RECEPTACLES
SWITCHED RECEPTACLES
SWITCHED RECEPTACLES
SWITCHED RECEPTACLES
Co
py
rig
ht
Re
serv
ed
Da
te
Sca
le
Dra
win
g
Pro
ject
Pro
ject
Nu
mb
er
Sh
ee
t N
um
be
r
Th
is p
lan
an
d d
esi
gn
are
th
e e
xclu
siv
e p
rop
ert
y o
f
Th
ink
spa
ce A
rch
ite
ctu
re,
Pla
nn
ing
, In
teri
or
De
sig
n
(Th
ink
spa
ce)
an
d c
an
no
t b
e u
sed
or
rep
rod
uce
d w
ith
ou
t
wri
tte
n c
on
sen
t o
f T
hin
ksp
ace
. T
his
off
ice
sh
all
be
in
form
ed
of
an
y v
ari
ati
on
s fr
om
th
e i
nfo
rma
tio
n s
ho
wn
on
th
is
dra
win
g.
Do
no
t sc
ale
dra
win
gs.
Th
ink
spa
ce,
a p
art
ne
rsh
ip o
f:
Ro
n H
off
art
, A
rch
ite
ct A
IBC
M
ark
Ma
thia
sen
, A
rch
ite
ct A
IBC
To
dd
Du
st,
Arc
hit
ect
AIB
C
H
en
k K
am
pm
an
, A
rch
ite
ct A
IBC
Issu
ed
Fo
r
PRINTED:
Da
te
Re
vis
ion
s
No
.D
ate
De
scri
pti
on
200,
16
28 D
icks
on
Av
enu
e
Kel
ow
na
BC
V1
Y 9
X1
Ph
on
e:
(25
0) 8
60-
2257
Fax
:
(
250
) 8
60-2
523
ww
w.c
ima
.ca
11/15/2018 2:50:14 PM
K0
00
29
3A
FN
HA
PR
INC
E G
EO
RG
E O
FF
ICE
RE
NO
.
SC
HE
DU
LES
E-30
1
20
18
-11
-01
NT
S
20
0-1
77
VIC
TO
RIA
ST
RE
ET
PR
INC
E G
EO
RG
E,
B.C
.
V2
L 5
R8
FIR
ST
NA
TIO
NS
HE
ALT
H
AU
TH
OR
ITY
10
/03
/18
NTSE-301
1 PANEL 2C - EXISTING
NTSE-301
4 PANEL 6C - EXISTINGNTSE-301
5 PANEL 2CA - EXISTING
NTSE-301
2 PANEL A
NTSE-301
3 PANEL 2C - REVISED
12
01
8-1
0-0
5IS
SU
ED
FO
R C
OO
RD
INA
TIO
N
22
01
8-1
1-0
1IS
SU
ED
FO
R 9
5%
RE
VIE
W
32
01
8-1
1-0
9IS
SU
ED
FO
R B
UIL
DIN
G P
ER
MIT
42
01
8-1
1-1
5IS
SU
ED
FO
R B
I D
PART 1 - GENERAL
1.1 THE GENERAL CONDITIONS AND INSTRUCTIONS TO BIDDERS AS SET FORTH IN THE GENERALCONTRACT SPECIFICATIONS AND ALL ADDENDA THERETO SHALL APPLY TO, AND GOVERN ALLPORTIONS OF THE ELECTRICAL WORK.
1.2 POINTS NOT SPECIFICALLY MENTIONED SHALL BE IN STRICT ACCORDANCE WITH THE CURRENTVERSION OF THE CANADIAN ELECTRICAL CODE AND REGULATIONS OF THE ELECTRICAL INSPECTIONDEPARTMENT FROM WHICH THE PERMIT WAS OBTAINED.
1.3 WHERE THE TERMS "FURNISH", "PROVIDE" OR "INSTALL" APPEAR IN THIS DIVISION, OR AMANUFACTURER IS INDICATED WITH ITEM OR PRODUCT CATALOG NUMBER LISTED, IT IS THECONTRACTOR'S RESPONSIBILITY TO FURNISH AND INSTALL THE ITEM COMPLETE AND OPERATINGFOR THE PURPOSE OR FUNCTION INTENDED, UNLESS OTHERWISE NOTED.
PART 2 - CODES, PERMITS AND INSPECTIONS
2.1 THE INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE CURRENT EDITION OF THECANADIAN ELECTRICAL CODE (AS AMENDED BY THE AUTHORITY HAVING JURISDICTION), LOCALBUILDING CODE AND THE REGULATIONS OF THE ELECTRICAL INSPECTION DEPARTMENT HAVINGJURISDICTION.
2.2 THE ELECTRICAL TRADE SHALL OBTAIN ALL ELECTRICAL PERMITS REQUIRED AND, AFTERCOMPLETION OF THE WORK, SHALL FURNISH TO THE ENGINEER A CERTIFICATE OF FINALINSPECTION AND APPROVAL FROM THE INSPECTION DEPARTMENT.
2.3 FEES FOR ALL PERMITS AND LICENSES REQUIRED FOR THE WORK SHALL BE INCLUDED BY THEELECTRICAL CONTRACTOR.
PART 3 - STANDARD OF ACCEPTANCE
3.1 ALL MATERIALS SHALL BE NEW AND OF THE QUALITY SPECIFIED UNLESS SPECIFICALLY SHOWN ASEXISTING TO BE RE-USED IN THE CONTRACT DOCUMENTS. NEW MATERIALS SHALL CONFORM TOTHE STANDARDS OF THE CSA AND THE ULC AND APPROVED BY THESE AGENCIES, WHEREAPPLICABLE. FOR ANY MATERIAL NOT CSA APPROVED, THE CONTRACTOR SHALL OBTAIN THEAPPROVAL OF THE LOCAL INSPECTION AUTHORITY AND SHALL BEAR ALL INSPECTION CHARGESLEVIED AND ANY MODIFICATION COSTS REQUIRED.
3.2 ALL PHASES OF THE ELECTRICAL INSTALLATION SHALL BE EXECUTED IN A SATISFACTORY,WORKMANLIKE MANNER AND SHALL PRESENT A NEAT APPEARANCE WHEN COMPLETED. WORK NOTDEEMED SATISFACTORY TO THE ENGINEER SHALL BE CORRECTED AT THE CONTRACTOR'SEXPENSE.
PART 4 - SETTING OUT THE WORK
4.1 ELECTRICAL WORK IS TO BE CARRIED OUT BY QUALIFIED, LICENSED ELECTRICIANS WHO HOLD AVALID PROVINCIAL LICENSE IN ACCORDANCE WITH THE AHJ.
4.2 THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ALL WORK COMPLETEDCONTRARY TO THE INTENT OF THE DRAWINGS AND SPECIFICATIONS AND SHALL BEAR ALL COSTSFOR SAME. WHERE THE INTENT OF THE DRAWINGS AND SPECIFICATIONS ARE NOT CLEAN, THECONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITHTHE WORK.
4.3 WHERE ANY EQUIPMENT SUPPLIED BY THE ELECTRICAL TRADE MUST BE BUILT-IN WITH WORK OFOTHER CONTRACTORS, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THESUPPLYING OF THE EQUIPMENT TO BE BUILT-IN OR MEASUREMENTS TO ALLOW NECESSARYOPENINGS TO BE LEFT SO AS NOT TO HOLD UP THE WORK.
4.4 THE ELECTRICAL TRADE, IN SETTING OUT OF HIS WORK, SHALL MAKE REFERENCE TO ALL OTHERDISCIPLINES AND SPECIFICATIONS. THE ELECTRICAL CONTRACTOR SHALL CONSULT WITH THERESPECTIVE TRADES IN SETTING OUT LOCATIONS FOR ALL EQUIPMENT AND WIRING SO THATCONFLICTS ARE AVOIDED AND SYMMETRICAL SPACING IS MAINTAINED.
4.5 BEFORE SUBMITTING TENDER, CAREFULLY EXAMINE THE SITE OF THE PROPOSED WORK SO AS TOASCERTAIN ALL EXISTING CONDITIONS AFFECTING THE WORK. NO EXTRAS WILL BE ALLOWED FORWORK NECESSITATED BY CONDITIONS ORDINARILY EVIDENT ON THE SITE. REPORT TO THEENGINEER ANY CONDITIONS THAT MAY AFFECT THE PROPER COMPLETION OF THIS WORK.
4.6 WHERE LIGHTING FIXTURES, SPEAKERS, ETC. OCCUR IN ACOUSTIC TILE TYPE CEILING, THEFIXTURE OR SPEAKER LOCATION SHALL BE COORDINATED WITH THE TILE PATTERN AND SHALL BEADJUSTED, IF REQUIRED TO SUIT THE TILE PATTERN.
4.7 WHERE RECEPTACLES ARE MOUNTED ABOVE COUNTERS, BENCHES, BACKSPLASHES, ETC.,LOCATION AND MOUNTING HEIGHTS SHALL BE COORDINATED WITH THE BUILT-IN UNITS ANDARCHITECTURAL DRAWINGS.
4.8 MOUNTING HEIGHTS SHALL BE COORDINATED WITH ARCHITECTURAL DETAILS AND SHALL BEADJUSTED, IF REQUIRED, TO SUIT PANELING, DADOS, MASONRY COURSE LINES, ETC.
4.9 WHERE OUTLETS OCCUR IN THE WARM SIDE OF PERIMETER WALLS, THE ELECTRICALCONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE VAPOUR BARRIER AND ENSURE THERE ISINSULATION BEHIND THE OUTLET BOXES TO PREVENT CONDENSATION IN THE BOXES.
4.10 UPON INSTRUCTION FROM THE ENGINEER, AND PRIOR TO ORIGINAL INSTALLATION, OUTLETS MAYBE RELOCATED UP TO 3M FROM LOCATION SHOW ON DRAWINGS, AT NO ADDITIONAL COST.
4.11 OUTLETS LOCATED IN PARTY WALLS SHALL NOT BE INSTALLED BACK-TO-BACK, TO PREVENTSOUND TRANSMISSION.
4.12 INSTALLATION OF CONDUITS, OUTLETS AND EQUIPMENT IN MECHANICAL ROOMS SHALL NOTPROCEED UNTIL THE INSTALLATION OF MECHANICAL EQUIPMENT HAS PROGRESSED FAR ENOUGHTO AVOID CONFLICTS.
PART 5 - CUTTING AND PATCHING
5.1 THE BUILDING AND PARKADE CONTAIN POST TENSION CABLES WITHIN THE CONCRETE SLABS ANDSTRUCTURE. THE DETAILS OF ALL PROPOSED OPENINGS, PENETRATIONS AND INSERTS THROUGHTHE SLABS, BEAMS OR WALLS MUST BE SUBMITTED FOR REVIEW AND APPROVAL TO THESTRUCTURAL ENGINEER AND LANDLORD AND HIS BASE BUILDING STRUCTURAL ENGINEER. PROVIDEALL COSTS FOR X-RAY OR OTHER INVESTIGATIONS TO THE SATISFACTION OF THE LANDLORD PRIORTO ANY WORK WITH THE STRUCTURAL CONCRETE SYSTEMS.
5.2 STRUCTURAL MEMBERS SHALL NOT BE CUT WITHOUT THE CONSENT OF THE ENGINEER AND/ORSTRUCTURAL ENGINEER ON SITE. FOR ALL NECESSARY CUTTING, CORING, DRILLING, ETC., THEELECTRICAL CONTRACTOR SHALL PROVIDE HIS OWN FORCES AND NECESSARY EQUIPMENTREQUIRED TO COMPLETE THE WORK.
5.3 PRIOR TO RUNNING ANY DUCTS IN THE SLAB OR OTHER CONCRETE MEMBERS, CONTACT THESTRUCTURAL ENGINEER AND OBTAIN CONSENT, IN WRITING, FOR DOING SO.
PART 6 - SUBSTITUTIONS
6.1 WHERE EQUIPMENT IS SPECIFIED WITH A MANUFACTURER'S NAME, SUBSTITUTIONS MAY BEPERMITTED UPON WRITTEN APPROVAL OF THE ENGINEER NO LATER THAN THREE DAYS PRIOR TOTENDER CLOSING. SUBMIT A LIST OF PROPOSED EQUIVALENT PRODUCTS TO THE ENGINEER IN PDFFORMAT, VIA EMAIL. MATERIALS NOTED AS "EQUAL TO" MAY BE SUBSTITUTED FOR EQUAL ORSUPERIOR QUALITY WITHOUT WRITTEN APPROVAL.
6.2 ENSURE SPACE REQUIREMENTS ARE MET IF USING SERVICE AND DISTRIBUTION EQUIPMENT FROMALTERNATE MANUFACTURERS. FAILURE TO DO SO THAT REQUIRES REDESIGN OF ELECTRICALROOMS WILL NOT BE ACCEPTED. ENGINEER'S COST CAUSED BY FAILURE TO COMPLY WILL BECHARGED TO THE ELECTRICAL CONTRACTOR.
PART 7 - SHOP DRAWINGS
7.1 SUBMIT ELECTRONIC SETS OF MANUFACTURER'S DETAILED SHOP DRAWINGS, SPECIFICATIONS,DATA SHEETS, ETC. FOR EQUIPMENT INCLUDING, BUT NOT LIMITED TO: SWITCHGEAR,PANELBOARDS, SERVICE EQUIPMENT, SWITCHES, LIGHTING, CONTROLS OR AS MAY BECONSIDERED NECESSARY TO THE ENGINEER.
7.2 CIMA+ HAS ALLOWED FOR TWO SHOP DRAWING REVIEWS FOR EACH SYSTEM. ALL COSTSASSOCIATED WITH CIMA+ PROVIDING ADDITIONAL SHOP DRAWING REVIEWS SHALL BE HOURLY ATTHE CONTRACTOR'S COST.
7.3 NO PRODUCT IS TO BE ORDERED, INSTALLED OR RELATED WORK IS TO BE DONE UNTIL THE SHOPDRAWING HAS BEEN REVIEWED BY THE CONSULTANT. ANY ELECTRICAL COMPONENTS INSTALLEDOR RELATED WORK DONE WITHOUT REVIEWED SHOP DRAWINGS, SHALL BE REMOVED ANDREPLACED WITH REVIEWED COMPONENTS AND WORK AT THE CONSULTANT'S DISCRETION AND ATTHE CONTRACTOR'S COST.
7.4 ANY TIME SPENT BY THE CONSULTANT DUE TO CONTRACTOR EQUIPMENT SELECTIONS THATREQUIRE REDESIGN OR COORDINATION REVIEW WITH OTHER SYSTEMS OR DISCIPLINES SHALL BEPAID BY THE CONTRACTOR DIRECTLY TO THE CONSULTANT AT AN HOURLY COST. THECONTRACTOR SHALL REPLACE ANY ALTERNATE PRODUCTS WITH THE APPROVED PRODUCTSSHOULD THEY NOT MEET ALL THE REQUIREMENTS OF THE LAYOUTS, DIMENSIONS, PERFORMANCESPECIFICATIONS, DELIVERY TIME AND COORDINATION WITH OTHER DISCIPLINES TO THESATISFACTION OF THE CONSULTANT. THE CONTRACTOR SHALL ALLOW FOR ALL COSTS IN THEIRBASE TENDER PRICE FOR THESE REQUIREMENTS.
PART 8 - RECORD DRAWINGS
8.1 OBTAIN A WHITE SET OF PRINTS TO BE USED TO RECORD WORK AS INSTALLED. RECORD INCOLOURED PENCIL ALL CHANGES, ALTERATIONS OR ADDITIONS THAT OCCUR DURING THEPROGRESS OF WORK; INCLUDING ALL CHANGES TO THE ORIGINAL TENDER DRAWINGS COVERED BYADDENDA, CHANGE ORDERS, FIELD CHANGES, JOB CONDITIONS, ETC.
8.2 AT THE CONCLUSION OF THE JOB, FORWARD THE MARKED UP DRAWINGS TO THE ENGINEER FORUPDATING THE ORIGINAL DOCUMENTS. ALLOW $1,000 PLUS GST, WHERE APPLICABLE, IN BID PRICETO COVER THIS WORK.
PART 9 - OPERATION & MAINTENANCE MANUALS
9.1 BEFORE COMPLETION AND ACCEPTANCE OF THE PROJECT, SUBMIT AN ELECTRICAL SYSTEMOPERATION & MAINTENANCE MANUAL IN 2" (MINIMUM) D-RING BLACK BINDERS. MANUALS SHALLINCLUDE TECHNICAL DATA OF EACH PIECE OF EQUIPMENT AS WELL AS TESTS AND OPERATION ANDMAINTENANCE REQUIREMENTS NOT READILY APPARENT TO AN UNSKILLED USER OR ASREQUESTED BY THE OWNER'S REPRESENTATIVE. PROVIDE MANUAL AND SEMINAR WITH OWNER'SFORCES TO ENSURE PROPER OPERATION OF BUILDING PRIOR TO SUBSTANTIAL COMPLETION.PROVIDE A COVER PAGE ON THE BINDER FRONT AND SLEEVE. PROVIDE A PROJECT TEAM CONTACTLIST, TABLE OF CONTENTS AND LABELLED SECTION DIVIDERS. ALLOW FOR THREE HARD COPIESAND AN ELECTRONIC PDF IN THE BASE BID.
PART 10 - CHANGES TO WORK
10.1 ANY CHANGES TO THE CONTRACT DOCUMENTS REQUIRES A CONTEMPLATED CHANGE NOTICEPRODUCED BY THE CONSULTANT AND ISSUED AS A CHANGE ORDER BY THE COORDINATINGPROFESSIONAL PRIOR TO ANY RELATED WORK COMMENCING.
10.2 QUOTES SUBMITTED BY THE CONTRACTOR MUST COME COMPLETE WITH AN ITEMIZEDBREAKDOWN OF MATERIAL AND LABOUR COSTS. QUANTITIES MUST BE CLEARLY DEFINED IN EITHERMETRIC OR IMPERIAL UNIT MEASUREMENTS. MATERIAL UNIT COSTS MUST BE CLEARLY DEFINED ASA COST PER UNIT OF MEASUREMENT (IE. $/FT). LABOUR UNIT COSTS MUST BE DEFINED AS A COSTPER UNIT OF TIME (IE. $/H).
10.3 ANY ENGINEERING DESIGN, REVIEW, APPROVAL AND SITE INSPECTIONS REQUIRED BY PROPOSEDCHANGES MADE BY THE CONTRACTOR, GC OR OTHER SUB-CONTRACTOR SHALL BE PAID DIRECTLYTO THE CONSULTANT BY THE CONTRACTOR, GC OR OTHER SUB-CONTRACTOR PROPOSING THECHANGES AT A RATE OF $150/HR PLUS EXPENSES. NO ENGINEERING WORK WILL PROCEEDWITHOUT A SIGNED PURCHASE ORDER TO THE CONSULTANT FROM THE APPLICABLE CONTRACTOR.
PART 11 - TESTING
11.1 PERFORM MEGGER TESTS ON ALL FEEDERS TO ENSURE THAT THE C.E.C. REQUIREMENTS ARE MET.TAKE CURRENT READINGS ON ALL FEEDERS AND IF LOAD UNBALANCE EXCEEDS 15%, RECONNECTLOADS TO BRING WITHIN BALANCE.
PART 12 - GUARANTEE/WARRANTY
12.1 THE ELECTRICAL CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE FOR THE FOLLOWING:
.1 ALL WORK EXECUTED UNDER THIS CONTRACT WILL BE FREE FROM DEFECTS OF WORKMANSHIPAND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION.
.2 CONTRACTOR AGREES THAT IT WILL, AT ITS OWN EXPENSE, REPAIR AND REPLACE ALL SUCHDEFECTIVE WORK AND OTHER WORK DAMAGED THEREBY WHICH FAILS OR BECOMESDEFECTIVE DURING THE TERM OF THE WARRANTY PERIOD PROVIDED SUCH FAILURE IS NOT ARESULT OF IMPROPER USAGE.
.3 THE PERIOD OF THE GUARANTEE SPECIFIED SHALL IN NO WAY SUPPLANT ANY OTHERGUARANTEE OF A LONGER PERIOD, BUT SHALL BE BINDING ON WORK NOT OTHERWISECOVERED.
PART 13 - WIRING METHODS
13.1 ALL WIRING TO BE COPPER, UNLESS OTHERWISE NOTED.
13.2 ALL CABLING SHALL BE FT4 RATED EXCEPT IN PLENUM SPACES WHICH SHALL BE FT6 RATED. NOTETHAT THE T-BAR CEILING SPACES FOR THIS PROJECT ARE PLENUM SPACES SO ALL WIRING WITHINTHAT SPACE SHALL BE FT6.
13.3 FEEDERS SHALL BE SIZED WITH A MAXIMUM OF 2% VOLTAGE DROP.
13.4 BRANCH CIRCUIT WIRING SHALL BE MINIMUM #12 AWG 90C RATED IN EMT OR AC-90 MAY BE USED,WHERE PERMITTED BY CODE. WHERE WIRE SIZES ARE NOT SHOWN, THE AMPACITY MUST MATCHOR EXCEED THAT OF THE PROTECTIVE DEVICE.
13.5 FLEXIBLE CONDUIT CONNECTIONS TO MOTORS, CONTROL, ETC. TO BE FLEXIBLE PLASTICJACKETED, SEAL TIGHT OR APPROVED EQUAL. FLEXIBLE CONNECTIONS ARE REQUIRED TO ALLMOTORS FROM STUB-UPS OR JUNCTION BOXES. MAXIMUM LENGTH PERMITTED IS 3 FT.
13.6 CONDUIT TO BE SIZED IN ACCORDANCE WITH TABLE 6 OF THE CANADIAN ELECTRICAL CODE.CONDUITS TO BE INSTALLED FREE FROM DENTS. CONDUIT ENDS ARE TO BE PLUGGED TO PREVENTENTRANCE OF DIRT OR MOISTURE.
13.7 ALL PENETRATIONS OF FIRE RATED ASSEMBLIES ARE TO BE SEALED WITH AN APPROVED FIRESTOP SYSTEM SUCH THAT THE PENETRATED MEMBRANE IS MAINTAINED IN ACCORDANCE WITH THELOCAL BUILDING CODE.
.1 INSTALL ALL FIRE STOPPING IN ACCORDANCE WITH ULC FIRE RESISTANCE DIRECTORY OR ULPRODUCTS CERTIFIED FOR CANADA (CUL) DIRECTORY.
.2 INSTALL FIRE STOPPING AS PER MANUFACTURER'S RECOMMENDATIONS.
.3 REFER TO ARCHITECTURAL DRAWINGS FOR RATINGS OF ALL WALLS AND FLOORS.
13.8 WIRING SHALL BE INSTALLED CONTINUOUSLY WITHIN RACEWAYS. SPLICING SHALL ONLY BEPERMITTED AT OUTLETS AND JUNCTION BOXES.
13.9 PROVIDE A BONDING WIRE IN ALL RACEWAYS.
13.10 ALL WIRING TO BE CONCEALED IN WALLS, CEILINGS OR FLOORS, WHERE POSSIBLE. EXPOSEDCONDUIT OR WIRING SHALL BE RUN PARALLEL TO OR AT RIGHT ANGLES TO THE BUILDING LINES.
13.11 PULL BOXES SHALL BE INSTALLED TO BE AS HIDDEN AS POSSIBLE WITHOUT IMPEDING ACCESS.
PART 14 - WIRING DEVICES
14.1 LIGHT SWITCHES SHALL BE COMMERCIAL GRADE, DECORA STYLE, 15 OR 20A AS REQUIRED, WHITEFINISH, UNLESS OTHERWISE NOTED.
14.2 RECEPTACLES SHALL BE COMMERCIAL GRADE, DECORA STYLE, 15 OR 20A AS REQUIRED, WHITEFINISH, UNLESS OTHERWISE NOTED.
14.3 COVER PLATES SHALL BE THERMOPLASTIC IN FINISHED AREAS WITH COLOUR TO MATCH DEVICES.PROVIDE STAMPED METAL COVER PLATES IN UNFINISHED AREAS AND WEATHERPROOF 'IN-USE'COVERS FOR EXTERIOR RECEPTACLES.
14.4 LINE VOLTAGE DIMMERS SHALL BE EQUAL TO LEVITON DECORA ROCKER-SLIDE UNIVERSAL SERIES(1000W), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLE SWITCHES.
14.5 0-10VDC DIMMERS SHALL BE EQUAL TO LEVITON DECORA ROCKER-SLIDE ADVANCE MARK 7 SERIES(1200VA), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLE SWITCHES.
14.6 ELECTRONIC LOW VOLTAGE DIMMERS SHALL BE EQUAL TO LEVITON DECORA ROCKER-SLIDEUNIVERSAL SERIES (600VA), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLE SWITCHES.
14.7 LINE VOLTAGE SWITCHES WITH INTEGRAL PIR OCCUPANCY SENSORS SHALL BE EQUAL TO LEVITONDECORA ODS15-ID (1800VA), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLE SWITCHES.
14.8 LINE VOLTAGE SWITCHES WITH INTEGRAL PIR/ULTRASONIC OCCUPANCY SENSORS SHALL BEEQUAL TO LEVITON DECORA OSSMT-MD (800W), WITH IVORY FINISH. DO NOT GANG WITH STANDARDTOGGLE SWITCHES.
14.9 LINE VOLTAGE SWITCHES WITH INTEGRAL PIR OCCUPANCY SENSORS AND 0-10V DIMMING SHALL BEEQUAL TO LEVITON OSD10-10 (800W), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLESWITCHES. (ASHRAE 90.1 COMPLIANT)
14.10 LINE VOLTAGE CEILING MOUNT PIR OCCUPANCY SENSORS SHALL BE EQUAL TO LEVITON PROVOLTSERIES ODC15-ID (800W, 360°, 1500SQFT COVERAGE), WITH WHITE FINISH.
14.11 LINE VOLTAGE CEILING MOUNT PIR/ULTRASONIC OCCUPANCY SENSORS SHALL BE EQUAL TOLEVITON PROVOLT SERIES ODC20-MDW (800W, 360°, 2000SQFT COVERAGE), WITH WHITE FINISH.
14.12 LINE VOLTAGE WALL/CORNER MOUNT PIR OCCUPANCY SENSORS (WIDE VIEW) SHALL BE EQUAL TOLEVITON ODWWV-ID (15A, 110°, 2500SQFT COVERAGE), WITH WHITE FINISH.
14.13 LINE VOLTAGE WALL/CORNER MOUNT PIR OCCUPANCY SENSORS (LONG RANGE AISLE) SHALL BEEQUAL TO LEVITON ODWLR-ID (15A, 110°, 1200SQFT COVERAGE), WITH WHITE FINISH.
14.14 LINE VOLTAGE WALL/CORNER MOUNT PIR/ULTRASONIC OCCUPANCY SENSORS SHALL BE EQUAL TOLEVITON ODW12-MDW (15A, 100FT X 14FT @ 10FT MOUNTING HEIGHT), WITH WHITE FINISH.
PART 15 - MOUNTING HEIGHTS
15.1 MOUNTING HEIGHTS SHALL BE FROM THE FINISHED FLOOR TO THE CENTRE OF EQUIPMENT, UNLESSOTHERWISE NOTED. IF MOUNTING HEIGHT IS NOT SPECIFIED, VERIFY WITH ENGINEER PRIOR TOINSTALLATION.
.1 SWITCHES: 1200MM (48 IN.)
.2 RECEPTACLES: 305MM (12 IN.)
.3 TELEPHONE/DATA/TELEVISION OUTLETS: 450MM (18 IN.)
.4 FIRE ALARM PULL STATIONS: 1200MM (48 IN.)
.5 FIRE ALARM BELL/STROBES: NO LESS THAN 2000MM (79 IN.) AND NO MORE THAN 2400MM (95 IN.)
.6 COUNTER-TOP OUTLETS: 1120MM (44 IN.)
PART 16 - IDENTIFICATION
16.1 LABEL ALL PANELS, STARTERS, DISTRIBUTION CENTRES, LIGHTING CONTROLS, TRANSFORMERSWITH 13MM LAMICOID PLATES, PERMANENTLY ATTACHED TO THE EQUIPMENT.
16.2 PROVIDE ADHESIVE LABELS FOR RECEPTACLE CIRCUIT NUMBERS AND VOICE/DATA JACKIDENTIFICATION.
PART 17 - DISCONNECT SWITCHES
17.1 DISCONNECT SWITCHES SHALL BE EQUAL TO EATON DH1 SERIES, WEATHERPROOF WHERE NOTED.
PART 18 - MOTOR STARTERS
18.1 MANUAL MOTOR STARTERS EQUAL TO EATON B100 SERIES.
18.2 MAGNETIC MOTOR STARTERS SHALL BE EQUAL TO EATON A200 SERIES WITH HOA CONTROLS ANDAUXILIARY CONTACTS.
PART 19 - MECHANICAL AND OTHER EQUIPMENT
19.1 PROVIDE WIRING, CONNECTIONS, STARTERS, DISCONNECTS AND CONTROLS FOR ALL MECHANICAL,OWNER AND OTHER TRADE INSTALLED EQUIPMENT.
19.2 PROVIDE FLEXIBLE CONNECTIONS AND VIBRATION ISOLATION TO ALL MECHANICAL EQUIPMENT.ALL CONNECTIONS TO EQUIPMENT IN WET LOCATIONS SHALL BE LIQUID-TIGHT.
19.3 CONTROL WIRING TO BE BY THE MECHANICAL CONTRACTOR. WHERE LINE VOLTAGE POWER ISREQUIRED FOR MECHANICAL EQUIPMENT, THE ELECTRICAL CONTRACTOR SHALL PROVIDE THECONNECTION.
PART 20 - ELECTRIC HEAT
20.1 BASEBOARD HEATERS SHALL BE EQUAL TO OUELLET OFM SERIES 208 VOLT, SINGLE PHASE,COMPLETE WITH BUILT-IN THERMOSTATS AS NOTED.
20.2 FORCE FLOW HEATERS SHALL BE EQUAL TO OUELLET OAC SERIES 208 VOLT, SINGLE PHASE,COMPLETE WITH BUILT-IN THERMOSTATS AS NOTED.
20.3 CEILING MOUNTED FORCE FLOW HEATERS SHALL BE EQUAL TO OUELLET OACP SERIES 208 VOLT,SINGLE PHASE, COMPLETE WITH REMOTE MOUNTED THERMOSTAT AND T-BAR CEILING ADAPTER.
20.4 KICKSPACE FAN HEATERS SHALL BE EQUAL TO OUELLET OCP SERIES 208 VOLT, SINGLE PHASE,COMPETE WITH BUILT-IN HEATER.
20.5 UNIT HEATERS SHALL BE EQUAL TO OUELLET OAS SERIES 208 VOLT, SINGLE PHASE, COMPLETEWITH REMOTE THERMOSTAT.
20.6 PROVIDE AND INSTALL REMOTE THERMOSTATS WHERE SHOWN ON THE DRAWINGS.
PART 21 - TELEPHONE & DATA SYSTEM
21.1 PROVIDE A COMPLETE VOICE AND DATA DISTRIBUTION SYSTEM. COMPLETE SYSTEM TO BESUPPLIED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, INCLUDING BUT NOT LIMITED TO:OUTLETS, CONNECTORS, CABLING, PATCH PANELS, PATCH CABLES, ETC.
21.2 PATCH PANELS, VOICE AND DATA JACKS AND CABLING SHALL BE CAT6 STYLE INSTALLED INEXISTING DATA RACK IN THE LAN ROOM. PROVIDE TYPED LABELS FOR CABLES TERMINATED ONPATCH PANELS.
21.3 PROVIDE 4" SQUARE BOX, SINGLE GANG PLASTER RING AND 3/4 CONDUIT STUBBED INTO CEILINGSPACE AND EXTEND TO CABLE TRAY.
21.4 CABLES SHALL BE SUPPORTED AT INTERVALS NO GREATER THAN 5'0" (1524MM).
21.5 CABLES SHALL NOT BE RUN WITHIN 12" (304MM) OF LIGHTING AND NOT LESS THAN 36" (914MM)FROM MOTORS, TRANSFORMERS OR OTHER ELECTRICAL EQUIPMENT.
21.6 CABLES TO BE RUN CONTINUOUSLY, WITH NO SPLICES AND MUST NOT EXCEED A TOTAL LENGTHOF 90M.
21.7 PROVIDE 'J' HOOKS FOR CABLE SUPPORT. HOOKS SHALL NOT EXCEED 40% OF THEIR FILL CAPACITY.
21.8 ALL CABLES MUST BE BLUE AND MARKED WITH A PERMANENT LABEL ON EACH END AND AT ALLINTERMEDIATE LOCATIONS.
21.9 DATA/VOICE JACKS SHALL BE BLUE WITH WHITE COVERPLATE AND HAVE ADHESIVE LABELS TOIDENTIFY EACH OUTLET.
21.10 PROVIDE RECORD DRAWINGS SHOWING LABELLING OF EACH DATA/VOICE JACK TO BE STORED INTELECOMMUNICATIONS ROOM.
21.11 ALL CABLES AND TERMINATION HARDWARE SHALL BE 100% TESTED FOR DEFECTS IN INSTALLATIONAND TO VERIFY CABLING SYSTEM PERFORMANCE UNDER INSTALLED CONDITIONS ACCORDING TOTHE REQUIREMENTS OF CSA T568.1, LATEST EDITION. SUBMIT TEST RESULTS OF ALL CABLETESTING TO THE ENGINEER.
PART 22 - LIGHTING
22.1 THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL LUMINAIRES NOTED ON THEDRAWINGS, COMPLETE WITH LAMPS, HANGERS, ACCESSORIES, ETC. FOR A COMPLETE ANDOPERATIONAL INSTALLATION.
22.2 LUMINAIRES SHALL BE LEFT CLEAN AT COMPLETION OF THE PROJECT WITH ALL LAMPSOPERATIONAL.
22.3 SUPPLY AND INSTALL LAMPS IN ALL EXISTING LUMINAIRES TO BE RE-USED. LAMPS SHALL MATCHEXISTING.
22.4 RE-BALLAST ALL EXISTING LUMINAIRES TO BE RE-USED.
22.5 REFER TO THE LUMINAIRE SCHEDULE FOR EACH TYPE REQUIRED TO MEET THE NEEDS OF THEPROJECT. ALTERNATES MAY BE CONSIDERED DURING THE TENDER PERIOD, REFER TO PART 7 -SUBSTITUTIONS.
PART 23 - LIGHTING CONTROLS
23.1 LIGHTING CONTACTORS SHALL BE EQUAL TO EATON TYPE A202, MAGNETICALLY LATCHED.
23.2 LIGHTING CONTROLS SHALL BE TESTED, BY A PARTY INDEPENDENT TO THE DESIGN ORCONSTRUCTION OF THE PROJECT, CERTIFICATION THAT ALL LIGHTING CONTROL DEVICES HAVEBEEN CALIBRATED, ADJUSTED, PROGRAMMED AND ARE IN PROPER WORKING ORDER INACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND MANUFACTURER'S RECOMMENDATIONS,WHICH INCLUDE THE FOLLOWING:
.1 CONFIRM PLACEMENT, SENSITIVITY AND TIME-OUT FOR OCCUPANCY SENSORS YIELDACCEPTABLE PERFORMANCE AND LIGHTS TURN OFF ONLY AFTER SPACE IS VACATED AND DONOT TURN ON UNLESS SPACE IS OCCUPIED.
.2 CONFIRM TIME SWITCHES AND PROGRAMMABLE SCHEDULES ARE PROGRAMMED TO TURNTHE LIGHTS OFF.
.3 PHOTO CONTROLS REDUCE LIGHTING LEVELS BASED ON AMOUNT OF USABLE DAYLIGHT INTHE SPACE.
PART 24 - GROUNDING
24.1 SUPPLY AND INSTALL COMPLETE GROUNDING AND BONDING SYSTEM AS INDICATED AND ASREQUIRED BY THE CURRENT EDITION OF THE CANADIAN ELECTRICAL CODE AND ELECTRICALINSPECTION DEPARTMENT. ALL COMPONENTS SHALL BE SECURELY AND ADEQUATELY GROUNDEDAND WHERE REQUIRED TO ACCOMPLISH THIS, GROUNDING JUMPERS, GROUNDING STUDS ANDBUSHINGS SHALL BE USED. ENSURE THAT ALL RACEWAYS, TERMINAL PANELS, ETC. FORTELEPHONE, LOW VOLTAGE, FIRE ALARM, SOUND, ETC. ARE SECURELY AND ADEQUATELYGROUNDED AND PROVIDE GROUNDING CONDUCTOR TO WATER MAIN WHERE CALLED FOR ORWHERE REQUIRED.
PART 25 - FIRE ALARM SYSTEM
.1 THE EXISTING FIRE ALARM SYSTEM SHALL BE MAINTAINED DURING CONSTRUCTION. NOCHANGES ARE ANTICIPATED FOR THE FIRE ALARM SYSTEM.
PART 26 - SECURITY - ACCESS CONTROL
26.1 FOUR DOOR CONTROLLER: KANTECH KT-400 DOOR CONTROLLER OR APPROVED EQUAL.
26.2 PROXIMITY CARDS & READERS: KANTECH IOPROX READERS OR APPROVED EQUAL, SINGLE GANGOR MULLION MOUNT, KEYPAD AS INDICATED ON DRAWINGS. KANTECH IOPROX CARDS, TAGS, ORKEY FOBS AS PER OWNER REQUIREMENTS.
26.3 REQUEST TO EXIT DETECTOR: KANTECH T.REX OR APPROVED EQUAL.
26.4 REQUEST TO EXIT PUSH BUTTON: KANTECH PB-EXIT OR APPROVED EQUAL.
26.5 ELECTRIC STRIKE: SECURITRON UNL FOR CYLINDRICAL/TUBULAR LOCKSET OR MUNL FOR MORTISETYPE LOCK, OR APPROVED EQUALS. FAIL SAFE OR FAIL SECURE AS INDICATED ON DRAWINGS.
26.6 MAGLOCK: SECURITRON MAGNALOCK M62 SERIES AND DM62 SERIES FOR DOUBLE DOORS ORAPPROVED EQUALS.
26.7 SOFTWARE: ENTRAPASS SPECIAL EDITION OR APPROVED EQUAL.
26.8 POWER TO COME FROM INDEPENDENT 120 VOLT, 15 AMP CIRCUIT. CIRCUIT DISCONNECT DEVICEACCESSIBLE TO AUTHORIZED PERSONNEL ONLY.
26.9 SYSTEM TO INCLUDE BATTERY BANK AND CHARGER WITH SUFFICIENT CAPACITY TO OPERATESYSTEM UNDER SUPERVISORY LOAD CONDITIONS WITHOUT RECHARGING FOR 12 CONSECUTIVEHOURS.
26.10 REQUEST TO EXIT PUSH BUTTON TO BE MOUNTED AT 1524MM A.F.F.
26.11 INTEGRATION WITH INTRUSION ALARM SYSTEM MAY BE ACCOMPLISHED BY CONNECTINGINTRUSION ALARM PANEL WITH DOOR CONTROLLER. ACCESS CONTROL SOFTWARE SHOULD BECAPABLE OF RECEIVING INTRUSION EVENTS, VIEW STATUS OF ZONES AND PARTITIONS, ANDPROGRAM USER CODES. SYSTEM MAY BE ARMED/DISARMED VIA A CARD READER OR MANUALLY VIATHE WORKSTATION SOFTWARE.
PART 27 - SECURITY - NETWORK VIDEO SURVEILLANCE (NVS)
27.1 PROVIDE A COMPLETE NETWORK VIDEO SURVEILLANCE (NVS) SYSTEM TO BE INSTALLED,CONNECTED, TESTED, AND LEFT IN FIRST-CLASS OPERATING CONDITION.
27.2 THE NVS SYSTEM IS COMPRISED OF SEVERAL COMPATIBLE, CSA APPROVED COMPONENTS. INGENERAL, THE SYSTEM INCLUDES FIXED DOME NETWORK CAMERAS, NETWORK VIDEO RECORDER,LCD MONITOR, CAMERA BRACKETS, CABLES, AND INSTALLATION HARDWARE.
27.3 THE NVS SYSTEM WILL CONTINUOUSLY MONITOR ALL CAMERA POSITIONS IN SEQUENCEDETERMINED BY AN ADJUSTABLE DWELL TIME, AND DISPLAY THE VIDEO IMAGE ON THE PROVIDEDMONITOR.
27.4 NETWORK VIDEO RECORDER: PANASONIC WJ-NV200 OR APPROVED EQUAL.
27.5 NETWORK FIXED DOME CAMERA (INTERIOR): PANASONIC WV-SFR310A OR APPROVED EQUAL.PROVIDE WIDE-ANGLE LENS WHERE NOTED.
27.6 MONITOR: PANASONIC PLCD24HDA 24" LCD DISPLAY OR APPROVED EQUAL.
27.7 SOFTWARE: PANASONIC WV-ASM200W RECORDING MANAGEMENT SOFTWARE OR APPROVED EQUAL.
PART 28 - SEISMIC PROTECTION
28.1 THE ELECTRICAL CONTRACTOR SHALL PROVIDE SEISMIC RESTRAINT AND ANCHORAGE FOR ALLELECTRICAL EQUIPMENT AND SERVICES IN ACCORDANCE WITH THE CURRENT EDITION OF THE BCBUILDING CODE AND ALL APPLICABLE BUILDING BYLAWS.
28.2 INCLUDE IN THE TENDERED PRICE ALL SERVICES OF A REGISTERED PROFESSIONAL IN THE FIELDOF SEISMIC RESTRAINT TO PROVIDE SUPPLEMENTAL SCHEDULE S LETTERS OF ASSURANCE INRESPECT OF THE SEISMIC RESTRAINT OF ALL ELECTRICAL MATERIALS AND EQUIPMENT,CONDUCTING THE NECESSARY SITE REVIEWS AND PROVIDING A LETTER AT THE CONCLUSION OFTHE PROJECT CONFIRMING THAT ALL SEISMIC RESTRAINTS FOR THE ELECTRICAL WORKS HAVEBEEN INSTALLED IN ACCORDANCE WITH THE ENGINEER'S INSTRUCTIONS. SUPPLEMENTALSCHEDULES TO BE SUBMITTED TO THE ELECTRICAL ENGINEER OF RECORD.
PART 29 - FIELD REVIEWS
29.1 THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CALLING THE ENGINEER, AS REQUIRED BYTHE LOCAL BUILDING CODE, FOR FIELD REVIEWS AT ROUGH-IN, SUBSTANTIAL COMPLETION ANDTHE COMPLETION OF ANY DEFICIENCIES.
29.2 THE ELECTRICAL CONTRACTOR MUST GIVE THE ENGINEER TWO BUSINESS DAYS' NOTICE FOR ALLREVIEWS.
29.3 FAILURE TO INFORM THE ENGINEER OF PROGRESS MAY RESULT IN THE ENGINEER BEING UNABLETO ISSUE AN ASSURANCE OF PROFESSIONAL FIELD REVIEW AND COMPLIANCE (SCHEDULE C-B) TOTHE BUILDING AUTHORITY.
Co
py
rig
ht
Re
serv
ed
Da
te
Sca
le
Dra
win
g
Pro
ject
Pro
ject
Nu
mb
er
Sh
ee
t N
um
be
r
Th
is p
lan
an
d d
esi
gn
are
th
e e
xclu
siv
e p
rop
ert
y o
f
Th
ink
spa
ce A
rch
ite
ctu
re,
Pla
nn
ing
, In
teri
or
De
sig
n
(Th
ink
spa
ce)
an
d c
an
no
t b
e u
sed
or
rep
rod
uce
d w
ith
ou
t
wri
tte
n c
on
sen
t o
f T
hin
ksp
ace
. T
his
off
ice
sh
all
be
in
form
ed
of
an
y v
ari
ati
on
s fr
om
th
e i
nfo
rma
tio
n s
ho
wn
on
th
is
dra
win
g.
Do
no
t sc
ale
dra
win
gs.
Th
ink
spa
ce,
a p
art
ne
rsh
ip o
f:
Ro
n H
off
art
, A
rch
ite
ct A
IBC
M
ark
Ma
thia
sen
, A
rch
ite
ct A
IBC
To
dd
Du
st,
Arc
hit
ect
AIB
C
H
en
k K
am
pm
an
, A
rch
ite
ct A
IBC
Issu
ed
Fo
r
PRINTED:
Da
te
Re
vis
ion
s
No
.D
ate
De
scri
pti
on
200,
16
28 D
icks
on
Av
enu
e
Kel
ow
na
BC
V1
Y 9
X1
Ph
on
e:
(25
0) 8
60-
2257
Fax
:
(
250
) 8
60-2
523
ww
w.c
ima
.ca
11/15/2018 2:50:14 PM
K0
00
29
3A
FN
HA
PR
INC
E G
EO
RG
E O
FF
ICE
RE
NO
.
SP
EC
IFIC
AT
ION
S
E-40
0
20
18
-11
-01
NT
S
20
0-1
77
VIC
TO
RIA
ST
RE
ET
PR
INC
E G
EO
RG
E,
B.C
.
V2
L 5
R8
FIR
ST
NA
TIO
NS
HE
ALT
H
AU
TH
OR
ITY
10
/03
/18
12
01
8-1
0-0
5IS
SU
ED
FO
R C
OO
RD
INA
TIO
N
22
01
8-1
1-0
1IS
SU
ED
FO
R 9
5%
RE
VIE
W
32
01
8-1
1-0
9IS
SU
ED
FO
R B
UIL
DIN
G P
ER
MIT
42
01
8-1
1-1
5IS
SU
ED
FO
R B
I D