correspondence address: 1017, adarsh nagar, new … address: 1017, adarsh nagar, new link road, opp....

20
Correspondence Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692 4175 / 6697 5447 / 6573 8689 / 6574 7931. Fax : 022- 67103445 E-mail : [email protected] / [email protected] Web-site : www.dynamicmarketing.in Sole Distributor and Agents in India for :

Upload: doanthu

Post on 30-Mar-2018

223 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

Correspondence Address: 1017, Adarsh Nagar, New Link Road,

Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102.

Tel : 022- 26741904 / 6692 4175 / 6697 5447 /

6573 8689 / 6574 7931. Fax : 022- 67103445

E-mail : [email protected] / [email protected]

Web-site : www.dynamicmarketing.in

Sole Distributor and Agents in India for :

Page 2: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

MOTOR + FAN BLADE PAIRING (COUPLING)MOTOR + FAN BLADE PAIRING (COUPLING)MOTOR + FAN BLADE PAIRING (COUPLING)MOTOR + FAN BLADE PAIRING (COUPLING)

& Technical Details& Technical Details& Technical Details& Technical Details

For Aluminium Blade

Part No. Motors (In Watts) (In HP)

Blade Dia + Pitch (Inch)

Watt In

Watt Out

Air Flow Cm3h

Static Pressure mm H2O

Current (amp)

154 - 28° (6”)

233 5.0 Motor N 05-

13 / 100 5 Watts

(1/110 HP) 172 - 28° (7”)

5 32 340 5.2

0.26

200 - 28° (8”)

483 7.2 Motor N 10-

20 / 107 10 Watts (1/83 HP) 230 - 28°

(9”)

10 38 700 5.0

0.35

254 - 28° (10”)

980 9.0 0.50 Motor N 16-

30 / 013 16 Watts (1/35 HP) 300-22°

(12”)

16 65 1100 8.5

254 - 28° (10”)

1000 12.0 Motor N 25-

40 / 481 25 Watts (1/20 HP) 300 - 28°

(12”)

25 95 1500 10.1

0.68

Motor N 34-45 / 014

34 Watts (1/10 HP)

300 – 34° (12”)

34 120 1700 8.4 0.87

For Plastic Blade Part No. Motors

(In Watts) (In HP)

Blade Dia + Pitch (Inch)

Watt In Watt Out

Air Flow Cm3h

Static Pressure mm H2O

Current (amp)

154 - 28° (6”)

200 4.8 Motor N 05-13 /

100

5 Watts (1/110 HP) 200 - 28°

(8”)

5 32 425 5.0

0.26

200 - 28° (8”)

475 6.5 Motor N 10-20 /

107

10 Watts (1/83 HP) 230 - 28°

(9”)

10 38 680 4.2

0.35

Motor N 16-30 /

013

16 Watts (1/35 HP)

254 - 28° (10”)

16 65 925 6.8 0.50

Note : Speed (RPM) for all the motors will be 1300 RPM

Page 3: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692
Page 4: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692
Page 5: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692
Page 6: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692
Page 7: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692
Page 8: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692
Page 9: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

P-P. 45'014 1 (1110 HP) -1 11 7 7 9 \

I , (1,llO w m y r ~~ - 2" ~'~*~. I '

Page 10: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

General Motor Knowledge Motor Sounds Lynn R. Dutro

What does a motor sound like? What should a motor sound like? Let's turn one of ours on and listen. AC power in this country alternates 50 times or 50 cycles each second. This is also known as 50 Hz pronounced 50 "hurts". The revolving magnetic field this sets up in our motor changes from north to south each cycle. Each change flexes the magnetic structure of the motor. Two changes for each of the 50 cycles results in 100 flexes of the magnetic structure each second. This is the characteristic 100 Hz "Hum..mm" associated with ac induction motors. The more powerful the motor, the more powerful the "hum..mm". The stator induces this same magnetic field into the rotor. But, the rotor "slips" or lags behind the stator's revolving field. The difference between the rotor speed and the speed of the revolving field results in a "beat" frequency. This is audible as a "wow.wow.wow", changing to a "wow.....wow" and finally to a "wow..ww" as the rotor approaches synchronization with the stator field. As the motor comes up to speed, harmonics cause variations in pitch such that the motor sounds like it is changing gears. Our motor is running. So what do we hear? The "hum..mm" from the stator with a very slow and not quite as strong "wow......wow" from the rotor. What else? Wind noise from moving air? What else? The shaft sliding in the bearing? But, with a film of oil in the bearing, this is almost no sound at all. Certainly not like the screech of metal on metal or the grating sound of sandpaper on a table top. Is the retaining washer on straight or do you hear it "tap..tap..tap" on the square nylon thrust washer? Do you hear a "bump..bump..bump" as the hub bounces along on the end of a bearing post that is not smooth and flat? If the end-bump sounds like a "clang..clang..clang", one of the padded washers was left out. Do you hear a "tick..tick..tick" from the rotor striking something in the air gap? Or a scratching sound like everything was turning in a bucket of sand? Does the rotor run smooth and free? Or can you hear and feel it as the out-of-balance weight is thrown from side to side? Do you hear a rattle from a loose mounting screw? If the metal fan blade is loose, it will ring like a gong. A happy motor should "hum..mm" merrily along. If it sounds like a wreck, it is asking for your help.

Page 11: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

General Motor Knowledge Motor Performance Curves

Lynn R. Dutro

A motor performance curve is a picture showing the relationship between inputs and outputs. Let's choose motor speed in revolutions per minute (RPM) as a reference point and look at torque. Torque is a measure of the force a motor can develope to turn something. Begin in the lower left corner of the picture. Draw a line of increasing speed up the page. This line begins at 0 RPM and extends to the synchronous or maximum speed, 1,5001 RPM for a 4-pole motor (at 50Hz, 1.800 at 60Hz). If the motor is not energized and RPM is zero, torque is also equal to zero. The lower left corner of our picture becomes RPM = 0 and TORQUE = 0. Speed increases up the page so we will choose torque increasing across the page to the right. Turn the motor on. Torque is developed in the rotor but the rotor has not started to turn yet. "Starting" torque is available to start the rotor turning and to accelerate it up to some operating speed. As speed increases, torque is affected by the various harmonics. Most noteable is the third harmonic. This harmonic is centered at one third the synchronous speed or 5002 RPM. It's negative most effect is seen as a dip in torque at about 7003 RPM. This is the infamous "third harmonic dip". Torque will continue to increase as speed increases until a speed of maximum torque is reached. This is often refered to as "breakdown' torque. From this point upward as speed increases torque will decrease. At synchronous speed, torque will equal to zero. The most desireable operating speeds are between synchronous and breakdown. If the motor load is greater than breakdown torque, the rotor stops turning because no more torque can be developed.

1 The sincronism RPM is defined as the maximum theoretical speed of a motor:

p2f60RPM ••

= - f= frequency; p=number of poles

2 These numbers have to be considered as examples only 3 These numbers have to be considered as examples only

Page 12: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

General Motor Knowledge Motor/Fan Performance

Lynn R. Dutro

Speed starts at 0 RPM in the lower left corner and increases up the page. Torque starts at 0, at the same place on the page as speed. Torque increases to the right across the page. The moment power is applied to the motor, RPM is still 0, while the motor develops some torque to start the rotor turning. This accelerates the rotor and speed increases. Torque and speed continue to increase with speed until torque reaches some maximum value. From this point, torque decreases as the rotor begins to revolve at the same speed as the magnetic field producing it. A fan blade requires torque in an amount proportional to the square of the speed. The speed-torque requirements for three fan blades are shown drawn on top of the motor speed-torque curve. The motor fan combination will operate where these curves intersect. Here the motor speed-torque fulfills the speed and torque requirement of the fan blade. A light fan requires very little from the motor. It operates at or near the motor maximum speed and does not utilize the motor's maximum power output. A heavy fan may not allow the motor to develop its full potential or come up to speed. The medium fan is the better choice. Think of the fan blade petal as a shovel. A child can move dirt with a small spade. An adult may take the same spade and dig faster but not move very much more dirt than did the child. Give the adult a shovel and scoop for scoop more dirt will be moved than with the small spade. If the shovel is so large that the adult must dig slowly, resting between scoops, it is again likely that not much dirt will be moved. It is also likely that the adult will overheat and quit. The motor and fan blade should be matched for best efficiency. This is easily done by overlaying the speed-torque curves of the motor and fan blade.

Page 13: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

General Motor Knowledge Motor Performance

Lynn R. Dutro Remember our motor speed-torque curve. Speed starts at 0 RPM in the lower left corner and increases up the page. Torque starts at 0, at the same place and increases to the right across the page. Remember also, a fan blade requires torque in an amount proportional to the square of the speed. The speed-torque requirements for three fan blades are shown drawn on top of the motor speedtorque curve. The motor fan combination will operate where the fan curve crosses the motor curve. A light fan requires very little from the motor. A heavy fan may not allow the motor to develop its full potential. We decided that a medium fan is the best choice. Let's see why. At any point along the motor speed-torque curve, torque multiplied times the speed, multiplied times a conversion number to get the units right is equal to WATTS OUTPUT. WATTS OUTPUT divided by the WATTS INPUT then times 100% is equal to the PERCENT EFFICIENCY. I have done the arithmetic and calculated a percent (%) efficiency curve for our motor performance curve. Percent efficiency starts at 0 in the lower left corner and increases to the right just as we did for torque. Note the speed where the medium fan curve and the motor performance curve cross. I have drawn a dotted line through this point. The motor efficiency at this speed (continue along the dotted line until it crosses the % efficiency curve) is very nearly maximum. At this point we are getting the MOST out of our motor/fan combination for the LEAST amount of power input. By following a similar process you can see that both the light fan and heavy fan will cause the motor to operate at a point of lower efficiency. This kind of graphical analysis is used to aid our customers in selecting desirable motor/fan combinations.

Page 14: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

ELCO S.p.A.VIA MARCONI, 120065 INZAGO MILANOITALIAPHONE +39 02 95319.1FAX +39 02 95310138E-mail: [email protected]

✱ ✱

✱✱

✱✱

U.K.SUBSIDIARY

SPAINSUBSIDIARY

ELCO MOTORES ESPAÑA SACALLE C, PARCELA 6, NAVE 2 POL. INDUSTRIAL EL OLIVERAL 46190 RIBARROJA - VALENCIAESPAÑAPHONE +34 96 1666346 FAX +34 96 1666087E-mail: [email protected]

CANADASUBSIDIARY

ELCO MOTORS INC.275 LIBERTE CANDIAC QC J5R 3X8 - CANADAPHONE +1 450 633 1515FAX +1 450 633 0851E-mail: [email protected]

U.S.A.SUBSIDIARY

ELCO AMERICA INC.P.O. BOX 458 147 W MICHIGAN AVE.CLINTON MI 49236-0458 USAPHONE +1 517 456 9690 FAX +1 517 456 9689E-mail: [email protected]

BRASILSUBSIDIARY

ELCO DO BRASIL LTDARUA MARCELO MORAES CORDEIRO, 190CEP 06765-280 TABOÃO DA SERRA - SP - BRASILPHONE +55 11 47878029 FAX +55 11 47873106E-mail: [email protected]

AUSTRALIASUBSIDIARY

ELCO MOTORS AND FANS PTY LTD84 NORTHGATE DRIVE THOMASTOWNVIC 3074 - AUSTRALIAPHONE +61 3 9464 2066 FAX +61 3 9464 2077E-mail: [email protected]

U.A.E.SUBSIDIARY

ELCO MOTORS LIMITEDJEBEL ALI FREE ZONE AREAP.O. BOX 18358, DUBAI - U.A.E.PHONE +971 (04) 8873330FAX +971 (04) 8873331E-mail: [email protected]

SINGAPORESUBSIDIARY

ELCO MOTORS ASIA PTE LTD22 KALLANG AVENUE #07-06 HONG AIK INDUSTRIAL BUILDINGSINGAPORE 339413PHONE +65 6298 9169 FAX +65 6291 6520E-mail: [email protected]

CHINASUBSIDIARY

ELCO CHINA LIMITEDHONG KONGDONGGUAN HENGLI ELCO CHINA MOTOR FACTORYXINCHENG INDUSTRIAL ZONE,HENGLI, GUANGDONG PROVINCE, PRCPHONE +86 769 3727378FAX +86 769 3727379E-mail: [email protected]

ELCO DIRECT LIMITEDUNIT A4, LAKE ENTERPRISE PARK,BIRKDALE RD, SOUTH PARK IND. ESTATE,BOTTESFORD, SCUNTHORPE,NORTH LINCOLNSHIRE, DN17 2AU - U.K.PHONE +44 1724 859900 FAX +44 1724 859922E-mail: [email protected]

World-Wide ELCO 2004/2005 2-09-2004 16:20 Pagina 1

Page 15: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

ITALIADISTRIBUTOR

RIVACOLD SRLVIA XXV APRILE, 6061020 MONTECCHIO (PS) - ITALIAPHONE +39 0721 499308FAX +39 0721 490015www.rivacold.com

PORTUGALDISTRIBUTOR

SKKRUA MONTE DOS PIPOS, ARMAZÉM 64460-059 GUIFÕES - PORTUGALPHONE +351 22 9571100FAX +351 22 9571137E-mail: [email protected]

AUSTRIADISTRIBUTOR

SOJKA GmbH & CO. KG.KLANGGASSE 2AA-1021 WIEN 2 - ÖSTERREICHPHONE +43 1 2163060FAX +43 1 2163697E-mail: [email protected]

FRANCEDISTRIBUTOR

SOCIETE D’APPAREILLAGES DIVERS S.A.PARC IND. DES 50 ARPENTS8, SQ. LOUIS BLANC77680 ROISSY-EN-BRIE - FRANCEPHONE +33 1 60183030FAX +33 1 60293898E-mail: [email protected]

GERMANYDISTRIBUTOR

GOVI GmbHCHRISTIAN-LASSEN-STRAßE 10bD-53117 BONN - GERMANYPHONE +49 0228 62932-60FAX +49 0228 62932-61E-mail: [email protected]

U.K.DISTRIBUTOR

DEAN & WOOD LIMITEDMOLE BUSINESS PARK 3STATION RD LEATHERHEAD,SURREY KT22 7BA - ENGLANDPHONE +44 1372 364292FAX +44 1372 364296E-mail: [email protected]

BELGIUMDISTRIBUTOR

FL. HEYNENRODE LEE UWLAAN, 15B-2640 MORTSEL - BELGIUMPHONE +32 3 4401900FAX +32 3 4401027E-mail: [email protected]

GERMANYDISTRIBUTOR

ROBERT SCHIESSLKOLPINGRING 1482041 OBERHACHING - GERMANYPHONE +49 89 613060FAX +49 89 61306171

GERMANYDISTRIBUTOR

REISSREICHERTWEG 163015 OFFENBACH MAINGERMANYPHONE +49 69 84090FAX +49 69 837239

SWITZERLANDDISTRIBUTOR

H. KOCH KÄLTE AGZIELSTRASSE 23POSTFACH 139APPENZELL 9050 - SCHWEIZPHONE +41 71 7874733FAX +41 71 7874734

CROATIADISTRIBUTOR

MB FRIGO d.o.o.BANI 81 10010 ZAGREB - CROATIAPHONE +385 1 6608002FAX +385 1 6608004

HUNGARYDISTRIBUTOR

EQUINOXE EXP-IMP TRADING CO. LTD.CZOBOR ST. 101147 BUDAPEST - HUNGARYPHONE +36 1 2511488FAX +36 1 2511376E-mail: [email protected]

SLOVENIJADISTRIBUTOR

EMPOR d.o.o.LESKOSKOVA 9aLJUBJANAD Z.R. 1000SLOVENIJAPHONE +386 1520 3820FAX +386 1520 3838E-mail: [email protected]

POLANDDISTRIBUTOR

POL STOWEST SPOLKA Z.O.O.UL.KRZEMIENIECKA 118WROCLAW 54-613 - POLANDPHONE +48 71 3736 213/211/212FAX +48 71 3736483E-mail: [email protected]

TÜRKIYEAGENTDISTRIBUTOR

FRIGOTERMTARLABASI CADDESI, 110 BEYOGLU ISTANBUL 80080TÜRKIYEPHONE +90 212 2501500FAX +90 212 2550114E-mail: [email protected]

GREECEAGENTDISTRIBUTOR

A. CORRES AND CO. UNLTD72 KOSTANTINOUPOLES STR.18344 MOSCHATO - GREECEPHONE +30 210 4823176FAX +30 210 4829378E-mail: [email protected]

BULGARIADISTRIBUTOR

KAMEO Ltd.178 DUNAV BLUD. SUITE 64021 PLOVDIV - BULGARIAFAX +359 32 953875E-mail: [email protected]

ROMANIADISTRIBUTOR

MIDAL111A, PANTELIMON RD73384 BUCHAREST - ROMANIAPHONE +40 1 2504757FAX +40 1 2507075

CZECH REPUBLICDISTRIBUTOR

FRIDANAIR s.r.o.UNIVERZITNI C.P. 107132012 PLZEN - CZECH REPUBLICPHONE +420 19 7421144FAX +420 19 7421584E-mail: [email protected]

HOLLANDDISTRIBUTOR

CENTERCONCYPRESBAAN 32 2908 LT CAPELLE A/D IJSSELHOLLANDPHONE +31 10 4584455FAX +31 10 4584748E-mail: [email protected]

RUSSIADISTRIBUTOR

CPS REFRIGERATION12, STRELBITSHENSKAYA STR.192102 ST. PETERSBURG - RUSSIAPHONE +7 812 3255794FAX +7 812 3255795E-mail: [email protected]

HOLLANDDISTRIBUTOR

ECRCOLLSEWEG 265674 TR NUENEN - HOLLANDPHONE +31 40 2990600FAX +31 40 2990699E-mail: [email protected]

NORWAYDISTRIBUTOR

HILLCOSTROMSVEIEN 3461081 OSLO - NORWAYPHONE +47 2317 5280FAX +47 2317 5281E-mail: [email protected]

SWEDENAGENT

NORDICOLD ABDATAVAGEN 1643632 ASKIM - SWEDENPHONE +46 31 680440FAX +46 31 285291 E-mail: [email protected]

[email protected]

FINLANDAGENT

REFAIR OYATOMITIE 1 - P.O. BOX 52HELSINKY 00370 - FINLANDPHONE +358 9 5657780FAX +358 9 56577880E-mail: [email protected]

DENMARKDISTRIBUTOR

JESSEN JURGENSENTEMPOVEJ 18-2202750 BALLERUP - DENMARKPHONE +45 70 270607FAX +45 70 263405E-mail: [email protected]

RUSSIADISTRIBUTOR

FEAMORDZHONIKIKIDZE STR. 11117419 MOSCOW - RUSSIAPHONE / FAX +7 095 9551640E-mail: [email protected]

ECUADORDISTRIBUTOR

SEIMALSA PADRE SOLANO, 223 Y ESCOBEDO,ESQ. 3 PISO, OFC. 1-2GUAYAQUIL - EQUADORPHONE +593 4 309124FAX +593 4 562003

SANTO DOMINGODISTRIBUTOR

JOHMAR TRADING CO.AVDA. G. WASHINGTON, ESQ.CAMBRONAL, EDIFICIO MELLA,APTO 403 - SANTO DOMINGOPHONE +851 809 6876201FAX +851 809 6825973

U.A.E.DISTRIBUTOR

NASER AL SAYER & CO. L.L.C.P.O. BOX 1825 - DUBAIUNITED ARAB EMIRATESPHONE +971 4 2222471 / 2284314FAX +971 4 2275803E-mail: [email protected]

INDIADISTRIBUTOR

M/S. DYNAMIC MARKETINGA-202, DHAVALGIRI APT.,LOKHANDWALA COMPLEX,ANDHERI(W) - MUMBAI - 400053 - INDIAPHONE +91 (022) 2674 1904 / 5697 5447FAX +91 (022) 5692 4175E-mail: [email protected]

KUWAITDISTRIBUTOR

AL HASAWI AIRCONDITIONING& REFRIGERATION EQPT. EST.P.O. BOX 1175 SAFAT13012 KUWAITPHONE +965 4769100FAX +965 4720091E-mail: [email protected]

MEXICOAGENTDISTRIBUTOR

SURAMERICANA DE MOTORES S.A.DE C.V.PONIENTE 134 N°682 BODEGA“C”COL. INDUSTRIAL VALLEJO DEL. AZCAPOTZALCOC.P. 02300 - MEXICO D.F.PHONE +52 5555 870343FAX +52 5555 870310E-mail: [email protected]

COLOMBIAAGENTDISTRIBUTOR

ELCO COLOMBIA LTDACALLE 22 N° 127-21 (FONTIBON)BOGOTÀ D.C. - COLOMBIAPHONE +57 1 2988030FAX +57 1 4182525E-mail: [email protected]

WW

09.0

4.50

0

World-Wide ELCO 2004/2005 2-09-2004 16:20 Pagina 2

Page 16: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

M-AT-044 (Dich_sprot).docdot

Dichiarazione di Conformità CEEC Declaration of Conformity

come definito nella Direttiva Bassa Tensione 73/23/CEE e nella Direttiva EMC 89/336/CEEas defined by the Low Voltage Directive 73/23/EEC and the EMC guideline 89/336/EEC

Tipo di macchinaType of machinery

Motori Elettrici NET4U05NNN201

Electric Motor

I prodotti sono sviluppati, progettati e costruiti in conformità alle Direttive Bassa Tensione 73/23/CEE e DirettivaEMC 89/336/CEE sotto la responsabilità diThe products are developped, designed and manufactured in accordance with the EC Directives Low Voltage 73/23/EEC and EMC Directive89/336/EEC, on the own responsability of

Azienda ELCO S.p.A. Via Marconi, 1Company 20065 Inzago (MI) ITALY

Sono state seguite le seguenti normative armonizzate:The following harmonized standards are used:

EN 60529 (70-1)Gradi di protezione degli involucri (Codici IP).Degrees of protection provided by enclosures (IP code).EN 50081-1 (CEI 110-7)Compatibilità elettromagnetica - Norma generica sull’emissione - Parte 1: Ambienti residenziali, commerciali edell’industria leggera.Electromagnetic compatibility - Generic emission standard - Parte 1: Residential, commercial and light industry.EN 60335-1 (61-50)Sicurezza degli apparecchi elettrici d’uso domestico e similare parte 1 Norme generali, relativi ai paragrafi 10-11-13-16-18-21-23-24.1-25-27-29.Safety of household and similar electrical applicances ; part.1 : General requirements (See Declaration of Conformity Directive 73/23/CEE and89/336/CEE relative at par. 10-11-13-16-18-21-23-24.1-25-27-29.I prodotti indicati non hanno nessun tipo di protezione contro funzionamenti anomali.The listed products are not th. prot. or imp. prot.

IEC 34-1Macchine elettriche rotanti; parte 1 Caratteristiche nominali e di funzionamentoRotating electrical machines; part 1 : ating and performance

La conformità alla Direttiva EMC 89/336/CEE é valida se il prodotto è collegato direttamente alla rete elettrica. Seil prodotto è assemblato in un sistema o combinato con altri prodotti, l’installatore è responsabile per il rispettodella Direttiva EMC del sistema completo.The compliance with EMC Directive 89/336/EEC is valid if the product is connected directly to the main supply. If the product is integrated in asystem or combined with other products the systemmanufacturer is responsible for compliance with EMC for thecomplete system.

Firma/Signature

Page 17: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

M-AT-044 (Dich_sprot).docdot

Dichiarazione di Conformità CEEC Declaration of Conformity

come definito nella Direttiva Bassa Tensione 73/23/CEE e nella Direttiva EMC 89/336/CEEas defined by the Low Voltage Directive 73/23/EEC and the EMC guideline 89/336/EEC

Tipo di macchinaType of machinery

Motori Elettrici NET4U10NNN201

Electric Motor

I prodotti sono sviluppati, progettati e costruiti in conformità alle Direttive Bassa Tensione 73/23/CEE e DirettivaEMC 89/336/CEE sotto la responsabilità diThe products are developped, designed and manufactured in accordance with the EC Directives Low Voltage 73/23/EEC and EMC Directive89/336/EEC, on the own responsability of

Azienda ELCO S.p.A. Via Marconi, 1Company 20065 Inzago (MI) ITALY

Sono state seguite le seguenti normative armonizzate:The following harmonized standards are used:

EN 60529 (70-1)Gradi di protezione degli involucri (Codici IP).Degrees of protection provided by enclosures (IP code).EN 50081-1 (CEI 110-7)Compatibilità elettromagnetica - Norma generica sull’emissione - Parte 1: Ambienti residenziali, commerciali edell’industria leggera.Electromagnetic compatibility - Generic emission standard - Parte 1: Residential, commercial and light industry.EN 60335-1 (61-50)Sicurezza degli apparecchi elettrici d’uso domestico e similare parte 1 Norme generali, relativi ai paragrafi 10-11-13-16-18-21-23-24.1-25-27-29.Safety of household and similar electrical applicances ; part.1 : General requirements (See Declaration of Conformity Directive 73/23/CEE and89/336/CEE relative at par. 10-11-13-16-18-21-23-24.1-25-27-29.I prodotti indicati non hanno nessun tipo di protezione contro funzionamenti anomali.The listed products are not th. prot. or imp. prot.

IEC 34-1Macchine elettriche rotanti; parte 1 Caratteristiche nominali e di funzionamentoRotating electrical machines; part 1 : ating and performance

La conformità alla Direttiva EMC 89/336/CEE é valida se il prodotto è collegato direttamente alla rete elettrica. Seil prodotto è assemblato in un sistema o combinato con altri prodotti, l’installatore è responsabile per il rispettodella Direttiva EMC del sistema completo.The compliance with EMC Directive 89/336/EEC is valid if the product is connected directly to the main supply. If the product is integrated in asystem or combined with other products the systemmanufacturer is responsible for compliance with EMC for thecomplete system.

Firma/Signature

Page 18: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

M-AT-044 (Dich_sprot).docdot

Dichiarazione di Conformità CEEC Declaration of Conformity

come definito nella Direttiva Bassa Tensione 73/23/CEE e nella Direttiva EMC 89/336/CEEas defined by the Low Voltage Directive 73/23/EEC and the EMC guideline 89/336/EEC

Tipo di macchinaType of machinery

Motori Elettrici NET4U16NNN002

Electric Motor

I prodotti sono sviluppati, progettati e costruiti in conformità alle Direttive Bassa Tensione 73/23/CEE e DirettivaEMC 89/336/CEE sotto la responsabilità diThe products are developped, designed and manufactured in accordance with the EC Directives Low Voltage 73/23/EEC and EMC Directive89/336/EEC, on the own responsability of

Azienda ELCO S.p.A. Via Marconi, 1Company 20065 Inzago (MI) ITALY

Sono state seguite le seguenti normative armonizzate:The following harmonized standards are used:

EN 60529 (70-1)Gradi di protezione degli involucri (Codici IP).Degrees of protection provided by enclosures (IP code).EN 50081-1 (CEI 110-7)Compatibilità elettromagnetica - Norma generica sull’emissione - Parte 1: Ambienti residenziali, commerciali edell’industria leggera.Electromagnetic compatibility - Generic emission standard - Parte 1: Residential, commercial and light industry.EN 60335-1 (61-50)Sicurezza degli apparecchi elettrici d’uso domestico e similare parte 1 Norme generali, relativi ai paragrafi 10-11-13-16-18-21-23-24.1-25-27-29.Safety of household and similar electrical applicances ; part.1 : General requirements (See Declaration of Conformity Directive 73/23/CEE and89/336/CEE relative at par. 10-11-13-16-18-21-23-24.1-25-27-29.I prodotti indicati non hanno nessun tipo di protezione contro funzionamenti anomali.The listed products are not th. prot. or imp. prot.

IEC 34-1Macchine elettriche rotanti; parte 1 Caratteristiche nominali e di funzionamentoRotating electrical machines; part 1 : ating and performance

La conformità alla Direttiva EMC 89/336/CEE é valida se il prodotto è collegato direttamente alla rete elettrica. Seil prodotto è assemblato in un sistema o combinato con altri prodotti, l’installatore è responsabile per il rispettodella Direttiva EMC del sistema completo.The compliance with EMC Directive 89/336/EEC is valid if the product is connected directly to the main supply. If the product is integrated in asystem or combined with other products the systemmanufacturer is responsible for compliance with EMC for thecomplete system.

Firma/Signature

Page 19: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

M-AT-044 (Dich_sprot).docdot

Dichiarazione di Conformità CEEC Declaration of Conformity

come definito nella Direttiva Bassa Tensione 73/23/CEE e nella Direttiva EMC 89/336/CEEas defined by the Low Voltage Directive 73/23/EEC and the EMC guideline 89/336/EEC

Tipo di macchinaType of machinery

Motori Elettrici NET4U25NN202

Electric Motor

I prodotti sono sviluppati, progettati e costruiti in conformità alle Direttive Bassa Tensione 73/23/CEE e DirettivaEMC 89/336/CEE sotto la responsabilità diThe products are developped, designed and manufactured in accordance with the EC Directives Low Voltage 73/23/EEC and EMC Directive89/336/EEC, on the own responsability of

Azienda ELCO S.p.A. Via Marconi, 1Company 20065 Inzago (MI) ITALY

Sono state seguite le seguenti normative armonizzate:The following harmonized standards are used:

EN 60529 (70-1)Gradi di protezione degli involucri (Codici IP).Degrees of protection provided by enclosures (IP code).EN 50081-1 (CEI 110-7)Compatibilità elettromagnetica - Norma generica sull’emissione - Parte 1: Ambienti residenziali, commerciali edell’industria leggera.Electromagnetic compatibility - Generic emission standard - Parte 1: Residential, commercial and light industry.EN 60335-1 (61-50)Sicurezza degli apparecchi elettrici d’uso domestico e similare parte 1 Norme generali, relativi ai paragrafi 10-11-13-16-18-21-23-24.1-25-27-29.Safety of household and similar electrical applicances ; part.1 : General requirements (See Declaration of Conformity Directive 73/23/CEE and89/336/CEE relative at par. 10-11-13-16-18-21-23-24.1-25-27-29.I prodotti indicati non hanno nessun tipo di protezione contro funzionamenti anomali.The listed products are not th. prot. or imp. prot.

IEC 34-1Macchine elettriche rotanti; parte 1 Caratteristiche nominali e di funzionamentoRotating electrical machines; part 1 : ating and performance

La conformità alla Direttiva EMC 89/336/CEE é valida se il prodotto è collegato direttamente alla rete elettrica. Seil prodotto è assemblato in un sistema o combinato con altri prodotti, l’installatore è responsabile per il rispettodella Direttiva EMC del sistema completo.The compliance with EMC Directive 89/336/EEC is valid if the product is connected directly to the main supply. If the product is integrated in asystem or combined with other products the systemmanufacturer is responsible for compliance with EMC for thecomplete system.

Firma/Signature

Page 20: Correspondence Address: 1017, Adarsh Nagar, New … Address: 1017, Adarsh Nagar, New Link Road, Opp. Oriental College, Oshiwara, Andheri(W). Mumbai-400 102. Tel : 022- 26741904 / 6692

M-AT-044 (Dich_sprot).docdot

Dichiarazione di Conformità CEEC Declaration of Conformity

come definito nella Direttiva Bassa Tensione 73/23/CEE e nella Direttiva EMC 89/336/CEEas defined by the Low Voltage Directive 73/23/EEC and the EMC guideline 89/336/EEC

Tipo di macchinaType of machinery

Motori Elettrici NET4U34NNN001

Electric Motor

I prodotti sono sviluppati, progettati e costruiti in conformità alle Direttive Bassa Tensione 73/23/CEE e DirettivaEMC 89/336/CEE sotto la responsabilità diThe products are developped, designed and manufactured in accordance with the EC Directives Low Voltage 73/23/EEC and EMC Directive89/336/EEC, on the own responsability of

Azienda ELCO S.p.A. Via Marconi, 1Company 20065 Inzago (MI) ITALY

Sono state seguite le seguenti normative armonizzate:The following harmonized standards are used:

EN 60529 (70-1)Gradi di protezione degli involucri (Codici IP).Degrees of protection provided by enclosures (IP code).EN 50081-1 (CEI 110-7)Compatibilità elettromagnetica - Norma generica sull’emissione - Parte 1: Ambienti residenziali, commerciali edell’industria leggera.Electromagnetic compatibility - Generic emission standard - Parte 1: Residential, commercial and light industry.EN 60335-1 (61-50)Sicurezza degli apparecchi elettrici d’uso domestico e similare parte 1 Norme generali, relativi ai paragrafi 10-11-13-16-18-21-23-24.1-25-27-29.Safety of household and similar electrical applicances ; part.1 : General requirements (See Declaration of Conformity Directive 73/23/CEE and89/336/CEE relative at par. 10-11-13-16-18-21-23-24.1-25-27-29.I prodotti indicati non hanno nessun tipo di protezione contro funzionamenti anomali.The listed products are not th. prot. or imp. prot.

IEC 34-1Macchine elettriche rotanti; parte 1 Caratteristiche nominali e di funzionamentoRotating electrical machines; part 1 : ating and performance

La conformità alla Direttiva EMC 89/336/CEE é valida se il prodotto è collegato direttamente alla rete elettrica. Seil prodotto è assemblato in un sistema o combinato con altri prodotti, l’installatore è responsabile per il rispettodella Direttiva EMC del sistema completo.The compliance with EMC Directive 89/336/EEC is valid if the product is connected directly to the main supply. If the product is integrated in asystem or combined with other products the systemmanufacturer is responsible for compliance with EMC for thecomplete system.

Firma/Signature