cost proposal by building surveying
TRANSCRIPT
-
7/29/2019 cost proposal by building surveying
1/17
Item
NrDescription Unit Qty
Rate
Rs.
Amount
Rs.
Fondation
1
Exacavation a trench for remove the roots &
chemical treatment. ft3
360.00 20.00 7,200.00
2
Chemical treatment for roots approved by
engineer. Item Sum 4,500.00
Floor Repair
3 Refill cracks on the floor,1:3 mortar, break crack
around and properly joint ft 25.00 20.00 500.00
4 Remove the existing cement renderig floor and
filling ,compacted by suitable material and
cocrete and rendering that floor. ft2
25.00 120.00 3,000.00
5 Removal of existing damage tils and replase with
approved manufacture, size, colour and design
laid on and including 3/4" thick cement and sand
1:3 bedding and pointing with 1/4" tile grout tomatch the colour of tiles. ft
216.00 250.00 4,000.00
6
Apply anti termite treatment (pest control)
approved by the engineer. ft2
230.00 125.00 28,750.00
7
Polish the discoloration floor area approved by
the engineer. ft2
140.00 20.00 2,800.00
Wall Repair
8 Remove the existing plaster on kitchen wall and
replastering with chiken mesh and applied the
match colour C.I.C. or equivalent qualityapplication of two coats and a primer undercoat. ft
212.00 110.00 1,320.00
9 Cleaning the wall surfase removing algae,fangi
and applied the match colour C.I.C. or
equivalent quality application of two coats and a
primer undercoat. ft2
22.00 60.00 1,320.00
10
Cleaning the wall surfase and apply engineer
approved water proof application and match
colour C.I.C. or equivalent quality application of
two coats and a primer undercoat. ft2
36.00 85.00 3,060.00
56,450.00Carried to collection
-
7/29/2019 cost proposal by building surveying
2/17
Item
NrDescription Unit Qty
Rate
Rs.
Amount
Rs.
Ceiling
11 Remove the existing ceiling and replace, by
using 2" x 2" swan soft wood fixed to the wall with
3"wire nails ft2
120.00 80.00 9,600.00
12 Apply anti termite wood protection paint for all
panels, one coat ft2 240.00 40.00 9,600.00
Roof
13 0.75' x 0.75' facia boards, Wrot wood, paint with
two coats of primer and one coat of
weathersheild paint, CIC or equalent ft 240 55 13,200.00
14 Apllying necessary wood preservatives to Ridge,
rafters and purlins ft 230 30 6,900.00
15 Remove and replased the damaged parts of roof
rafter ft 40 80 3,200.00
16 Remove and replased the damaged parts of roof
battence ft 80 20 1,600.00
17 Cut and remove branches of tree to provide
proper lighting and ventilation system. Item Sum 3,800.00
18 Replace rain water gutters 6" dia half round
UPVC eaves guter fixed to timber valance board
including gutter joiner and brackets fixed at 1'
centres ft 80.00 150.00 12,000.00
19Removal of existing roofing sheet and replase
with approved corrugated asbestos roofing
sheet with necessary fasteners and other fixing
arrangements including screws, washes. Sheets
to be lapped 300mm at ends and on corrugation
at sides to timber batterns 2" x 2" sized at 5" c/c . ft2
64.00 90 5,760.00
65,660.00Carried to collection
-
7/29/2019 cost proposal by building surveying
3/17
Item
NrDescription Unit Qty
Rate
Rs.
Amount
Rs.
Doors and Windows
20 Replace decayed window frame with well
preservatived timber and apply one coat of
varnish Nr 2.00 5,400.00 10,800.00
21 Cleaned and paint window grils,match colour
C.I.C. or equivalent quality application two coats
of anti corrosive paint ft2
110.00 50.00 5,500.00
22 Replace 5" x 2 1/2" in sized hinges in main door,
fixed to the door frame with brass nails Nr 3.00 250.00 750.00
23 Replace 4" x 1 1/2" in sized hinges in windoor,
fixed to the door frame with brass nails Nr 12.00 120.00 1,440.00
24
Apllying necessary wood preservatives to door
and windoor frame approved by engineer ft 220.00 40.00 8,800.00
8,800.00
Item
NrDescription Unit Qty
Rate
Rs.
Amount
Rs.
Carried to collection
-
7/29/2019 cost proposal by building surveying
4/17
Collection
From page Bill No. 1 / 2.4 / 1 of 4 56,450.00
From page Bill No. 1 / 2.4 / 2 of 4 65,660.00
From page Bill No. 1 / 2.4 / 3 of 4 8,800.00
130,910.00Total Cost
-
7/29/2019 cost proposal by building surveying
5/17
P009 EA
BILL NO 2 - LUX
SECTION
ITEM DESCRIPTION QTY UNIT RATE
SECTION G - THERMAL AND MOISTURE
PROTECTION
WET AREA WATERPROOFING
Cold applied damp proofing system including cement,
sand screed as per the drawings and specifications
A To floors 665 m2
B To skirting,300mm high 624 m
C To walls 168 m2
TERRACE
Terrace waterproofing system; complete all in
accordance with specifications and drawings
D Min. 50mm thick lightweight concrete screed to fall 298 m2
E Slip sheet 298 m2
F 4mm thick elastomeric bitumen membrane reinforced
with 180/m2 stable non woven polyester, finished both
sides with macro performed torch of film
298 m2
G 95g/m2 non woven synthetic geotextile 596 m2
H 75mm thick Styrofoam roofmate SL-X 298 m2
J 75mm thick reinforced concrete deck 298 m2
K Min. 150 mm waterproof membrane turned up 233 m
L Allow for waterproofing dressing around pipe
penetrations and rainwater outlets
Item
CAVITY WALLS
M Apply liquid applied water proofing membrane on outer
surface of inner leaf of the external cavity wall 113 m2
BIL
-
7/29/2019 cost proposal by building surveying
6/17
Rev.01
6.06.08
Carried to collection
ROOFING SYSTEM
A Min. 35mm thick lightweight concrete screed to fall 693 m2
B Min. 50mm thick lightweight concrete screed to fall 50 m2
C Slip sheet 743 m2
D 4mm thick elastomeric bitumen membrane reinforced
with 180/m2 stable non woven polyester, finished both
sides with macro performed torch of film
743 m2
E 95g/m2 non woven synthetic geotextile 1,486 m2
F 75mm thick Styrofoam roofmate SL-X 743 m2
G 75mm thick of 20-40mm aggregate balast 693 m2
H 75mm thick reinforced concrete deck 50 m2
J Min. 150 mm waterproof membrane turned up 325 m
K Allow for waterproofing dressing around pipe
penetrations and rainwater outlets
Item
SECTION G - THERMAL AND MOISTURE
PROTECTION [con't]
Roofing system; complete all in accordance with
specifications and drawings
-
7/29/2019 cost proposal by building surveying
7/17
Carried to collection
SUNDRIES
Additional items
The Contractor shall list here and price any items
shown on the drawings, mentioned in the
Specifications or required for the satisfactory
completion of this section, but not mentioned herein.
Any such items not listed below shall be deemed to be
included
SECTION G - THERMAL AND MOISTURE
PROTECTION [con't]
-
7/29/2019 cost proposal by building surveying
8/17
Carried to collection
Collection
From page Bill No. 2 / 2.4 / G / 1 of 4
From page Bill No. 2 / 2.4 / G / 2 of 4
From page Bill No. 2 / 2.4 / G / 3 of 4
SECTION G - THERMAL AND MOISTURE
PROTECTION [con't]
-
7/29/2019 cost proposal by building surveying
9/17
Carried to Bill No. 2.4 Summary
-
7/29/2019 cost proposal by building surveying
10/17
TERN MANGROVE
RY APARTMENTS
2.4 - G+5 FLOORS
AMOUNT (AED)
S OF QUANTITIES
-
7/29/2019 cost proposal by building surveying
11/17
-
7/29/2019 cost proposal by building surveying
12/17
-
7/29/2019 cost proposal by building surveying
13/17
-
7/29/2019 cost proposal by building surveying
14/17
-
7/29/2019 cost proposal by building surveying
15/17
Item
NrDescription Unit Qty
Rate
Rs.
Amount
Rs.
Floor Repair
3Refill cracks on the pavement with 1:3 mortar,
break crack around and properly joint(diagonal
cracks, vertical cracks and horizontal cracks) ft 9.00 45.00 405.00
Wall Repair
8Remove the existing plaster on kitchen wall
and replastering with chiken mesh and applied
the match colour C.I.C. or equivalent qualityapplication of two coats and a primer
undercoat. ft2
40.00 190.00 7,600.00
9 ft2
25.00 210.00 5,250.00
10
Cleaning the wall surfase and apply engineer
approved water proof application and match
colour C.I.C. or equivalent quality application
of two coats and a primer undercoat. ft2
27.00 160.00 4,320.00
3 Refill cracks on the pavement with 1:3 mortar,break crack around and properly joint ft 6.00 45.00 270.00
Tests for identify the dampness in the walls Item 2,500.00
Replacing cladding ft2 150.00 300.00 45,000.00
65,345.00
Item
NrDescription Unit Qty
Rate
Rs.
Amount
Rs.
Ceiling
11 Remove the existing ceiling and replace, by
using 2" x 2" swan soft wood fixed to the wall
with 3"wire nails ft2
40.00 300.00 12,000.00
12 Apply anti termite wood protection paint for all
panels, one coat ft2
230.00 92.00 21,160.00
Carried to collection
-
7/29/2019 cost proposal by building surveying
16/17
Roof
Cutting off of unnecessary projections of steel
bars and making good for them Prov sum 3,000.00
18 Replace rain water gutters 6" dia half round
UPVC eaves guter fixed to timber valance
board including gutter joiner and brackets fixed
at 1' centres ft 75.00 160.00 12,000.00
19 Removal of existing roofing sheet and replase
with approved corrugated asbestos roofing
sheet with necessary fasteners and other
fixing arrangements including screws, washes.
Sheets to be lapped 300mm at ends and on
corrugation at sides to timber batterns 2" x 2"sized at 5" c/c . ft2
80.00 350 28,000.00
Drainage
Widening of existing drainage with
manholes,including excavation, backfilling ,
reinforcement and finishing and connect to the
existing drainage arrangement. ft 60.00 450 27,000.00
Water supply
furnish 2 nr of 750L capacity water tank and
necessary pipe aand fittings Prov sum 10,000.00
making good for the Water leakages in
sanitery facilities Prov sum 5,000.00
A/C
Necessary rectification works related toexisting A/C system including repairs to the
drain lines and insulation any other repairing
works as necessary. Prov sum 30,000.00
Electrical
-
7/29/2019 cost proposal by building surveying
17/17
Repairing to the electrical works including all
rewiring, and necessary replacement of
accessaries and conduting and any other safty
measures required. Prov sum 45,000.00
193,160.00Carried to collection