cpg commercial - manchester total air · pdf fileproduct specifications ss-gcpg10 4/08...
TRANSCRIPT
PRODUCT SPECIFICATIONS
SS-GCPG10 www.goodmanmfg.com 4/08
Standard FeaturesEnvironmentally friendly R-410A refrigerantTuff Tube™ tubular heat exchangerHigh-effi ciency scroll compressorCopper tube / aluminum fi n coilsContactor with lugsHigh-capacity, steel-cased fi lter dryerSingle-point entry24-volt terminal stripConvertibleEasy to serviceBuilt-in fi lter rack with standard 2” fi ltersBottom utility entryComplies with California NOx emissions standardsARI Certifi ed; ETL Listed
Cabinet FeaturesHeavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint fi nishFull perimeter railCurb fi t
ContentsNomenclature ................................................. 2 Product Specifi cations ................................. 3Airfl ow Data .................................................... 4Cooling Data Summary .............................. 5Expanded Cooling Data .............................. 6Dimensions ...................................................... 8Wiring Diagram ...........................................12Accessories ....................................................16
••••••••••••••
•
••
The new Goodman® CPG Commercial Packaged Gas/Electric Units feature the environmentally friendly refrigerant R-410A, which is chlorine-free to help prevent damage to the ozone layer. Other features include our patented Tuff Tube™ dual-diameter tubular heat exchanger and a high-effi ciency scroll compressor. These units are housed in a heavy-gauge, galvanized-steel cabinet with UV-resistant power-paint fi nish.
CPG COMMERCIAL10-TON SELF-CONTAINED PACKAGED
GAS/ELECTRIC UNITS
11.5 EER / 80% SSE
THREE-PHASE
COOLING CAPACITY: 118,000 BTU/H
HEATING CAPACITY: 210,000 BTU/H
PRODUCT SPECIFICATIONS
2 www.goodmanmfg.com SS-GCPG10
NOMENCLATURE
C P G 060 070 1 D X X X
1 2 3 4,5,6 7,8,9 10 11 12 13 14 Factory-Installed Options
Brand Special Features
C Commercial X No FeaturesA GFCI, 120v/ 15amp, 2-plug
Configuration convience powered outlet (GFCI)P Packaged Multi-Position B Low Ambient 0 Deg. (LA)
C GFCI & LAApplication
C Cooling Special Treatment
G Gas Heat X No Treatment/ StandardH Heat Pump Aluminized Heat Exchanger (AH)
B AH/CCNominal Gross Cooling Capacity C AH/EC
036 3 Tons 120 10 Tons D AH/CC/EC048 4 Tons 150 12½ tons F SH/CC060 5 Tons 180 15 Tons G SH/EC072 6 Tons 240 20 Tons H SH/CC/EC090 7½ Tons 300 25 Tons J Treated Condenser Coil (CC)102 8½ Tons K Treated Evap Coil (EC)
L CC/ECHeating Capacity S Stainless Steel Heat Exchanger (SH)CPG CPC/CPH
070 70,000 BTU/h XXX No Heat Economizer Options (Factory Installed)
105 105,000 BTU/h 010 10 kW Electric Heater X No Economizer140 140,000 BTU/h 015 15 kW Electric Heater A Economizer, Enthalpy 0-100%210 210,000 BTU/h 020 20 kW Electric Heater with Barometric Relief350 350,000 BTU/h 025 25 kW Electric Heater B Economizer, Enthalpy 0-100%400 400,000 BTU/h with Power Exhaust
Voltage Supply Fan/Drive Type/Motor
1 208v 1 Phase 4 460v 3 Phase B Belt Drive2 220/240V 1 Phase 50 Hz 5 380/415v 3 Phase 50 Hz D Direct Drive3 208v 3 Phase 7 575v 3 Phase H High-Static Belt Drive
PRODUCT SPECIFICATIONS
SS-GCPG10 www.goodmanmfg.com 3
PRODUCT SPECIFICATIONS
CPG120***3B*** CPG120***4B*** CPG120***7B***Cooling CapacityTotal BTU/h 118,000 118,000 118,000Sensible BTU/h 87,300 87,300 87,300EER / IPLV 11.50 / 12.00 11.50 / 12.00 11.50 / 12.00Decibels 83.0 83.0 83.0ARI Reference #s 3023834 3023834 3023834Heating CapacityMax. Input BTU/h 210,000 210,000 210,000Output BTU/h 168,000 168,000 168,000Steady State Effi ciency 80 80 80Temperature Rise Range (°F) 25-55 25-55 25-55No. of Burners 6 6 6Evaporator Motor / CoilMotor Type Belt Drive Belt Drive Belt DriveIndoor Nominal CFM 4,000 4,000 4,000Indoor motor FLA (Cooling) 7.8 3.9 2.7Horsepower - RPM 2.0 - 1,725 2.0 - 1,725 2.0 - 1,725Piston Size (Cooling) 0.086 0.086 0.086Filter Size (4) 16” x 24” x 2” (4) 16” x 24” x 2” (4) 16” x 24” x 2”Drain Size (NPT) ¾” ¾” ¾”R-410A Refrigerant Charge Cir #1(oz.) 220 220 220R-410A Refrigerant Charge Cir #2(oz.) 220 220 220Evaporator Coil Face Area (ft²) 10.2 10.2 10.2Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16Belt Drive Evap Fan Data# of Wheels (D x W) (1) 15” x 15” (1) 15” x 15” (1) 15” x 15”Motor Sheave / Blower Sheave VL40 / AK74 VL40 / AK74 VL40 / AK74Belt AX51 AX51 AX51Rows Deep / Fins per Inch 4 / 14 4 / 14 4 / 14Condenser Fan / CoilQuantity of condenser Fan Motors 2 2 2Horsepower - RPM ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075Fan Motor Amps (Cooling) ea. 2.40 1.20 0.84Fan Diameter / # Fan Blades 22 / 3 22 / 3 22 / 3Outdoor Nominal CFM 7,200 7,200 7,200Face Area (ft²) 32.4 32.4 32.4Rows Deep/ Fins per Inch 2/2 rows 22 fpi 2/2 rows 22 fpi 2/2 rows 22 fpiElectrical DataVoltage/Phase/ Frequency 208-230/3/60 460/3/60 575/3/60Quantity of Compressors 2 2 2Compressor RLA / LRA ea. 16 / 110.0 7.8 / 52.0 5.7 / 38.9Standard Max Static 2.0” 2.0” 2.0”Outdoor Fan RLA ea. 2.40 1.20 0.89Total Unit Amps 45 22 16Min. Circuit Ampacity¹ 49 24 17Max. Overcurrent Protection (amps)² 60 30 20Entrance Power Supply Locating Dimple Locating Dimple Locating DimpleEntrance Control Voltage Locating Dimple Locating Dimple Locating DimpleOperating Weight (lbs) 1235 1235 1235Ship Weight (lbs) 1275 1275 1275
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
PRODUCT SPECIFICATIONS
4 www.goodmanmfg.com SS-GCPG10
AIRFLOW DATA
Standard Belt-Drive Down-shot
ESP, In
H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.2 4316 780 1.57 4118 738 1.36 3771 687 1.08 3376 644 0.850.4 4282 830 1.76 3928 786 1.4 3595 740 1.130.6 4232 874 1.87 3872 830 1.52 3444 786 1.20.8 3839 880 1.64 3367 836 1.271 3326 885 1.4
1.21.4
High-Static Belt-Drive Down-shot
ESP, In
H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.8 4188 943 2.11 3793 889 1.671 4305 1002 2.39 3836 946 1.89 3416 893 1.45
1.2 4324 1053 2.63 3879 1003 2.11 3425 951 1.631.4 4428 1109 2.92 3973 1056 2.35 3434 1009 1.81.6 4465 1160 3.2 4088 1113 2.67 3506 1068 2.11.8 4129 1168 2.9 3625 1122 2.32 3694 1175 2.65
Standard Belt-Drive Horizontal
ESP, In
H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.2 4391 737 1.48 4054 693 1.22 3760 645 0.970.4 4314 781 1.61 3969 737 1.29 3534 693 10.6 4255 826 1.69 3894 781 1.38 3447 743 1.090.8 4234 876 1.85 3792 832 1.471 3724 877 1.59
1.21.4
High-Static Belt-Drive Horizontal
ESP, In
H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.8
DO NOT OPERATE
4408 885 2.021 4464 940 2.29 3929 891 1.76
1.2 4585 996 2.58 4026 946 2 3436 897 1.461.4 4697 1049 2.92 4141 1001 2.26 3509 951 1.71.6 4264 1056 2.58 3663 1007 1.961.8 4359 1105 2.85 3785 1061 2.222 3907 1114 2.49
PRODUCT SPECIFICATIONS
SS-GCPG10 www.goodmanmfg.com 5
COOLING DATA SUMMARY
Indoor AirCondenser Air Temperature
75 85 95 105 115
SCFM WB TotalMBTU/h
SensMBTU/h
WattsKWH
TotalMBTU/h
SensMBTU/h
WattsKWH
TotalMBTU/h
SensMBTU/h
WattsKWH
TotalMBTU/h
SensMBTU/h
WattsKWH
TotalMBTU/h
SensMBTU/h
WattsKWH
3200
71 122.3 61.6 9.75 119.3 61.7 10.32 116.4 62.1 10.82 110.6 61.2 11.25 102.5 57.2 11.62
67 114.4 77.1 9.47 111.6 77.2 10.02 108.9 77.7 10.50 103.5 76.6 10.91 95.8 71.6 11.27
63 107.0 88.7 9.20 104.5 88.7 9.73 101.9 89.4 10.20 96.8 88.1 10.59 89.7 82.3 10.93
59 104.8 92.5 9.03 102.3 92.6 9.54 99.8 93.3 9.99 94.8 92.0 10.38 87.8 85.9 10.71
4000
71 132.4 69.2 9.98 129.3 69.3 10.56 126.1 69.8 11.08 119.8 68.8 11.52 111.0 64.3 11.90
67 123.9 86.6 9.69 121.0 86.7 10.25 118.0 87.3 10.75 112.1 86.1 11.17 103.8 80.4 11.54
63 116.0 99.6 9.41 113.2 99.7 9.96 110.4 100.4 10.43 104.9 99.0 10.84 97.2 92.5 11.19
59 113.5 103.9 9.23 110.8 104.1 9.76 108.1 104.8 10.23 102.7 102.7 10.62 95.1 95.1 10.97
4500
71 136.4 74.7 10.05 133.2 74.8 10.65 129.9 75.4 11.17 123.4 74.3 11.61 114.3 69.4 12.00
67 127.6 93.6 9.76 124.6 93.6 10.33 121.5 94.3 10.83 115.5 93.0 11.26 107.0 86.9 11.63
63 119.4 107.6 9.48 116.6 107.7 10.03 113.8 108.5 10.51 108.1 108.1 10.93 100.1 100.1 11.28
59 116.9 112.3 9.30 114.1 114.1 9.83 111.3 111.3 10.30 105.8 105.8 10.71 98.0 98.0 11.05
Sensible heat capacities shown are based on 80°F DB entering air at the evaporator coil.For sensible heat capacities at other than 80°F DB, deduct 84 BTU/h per 100 CFM of evaporator coil air for each degree below 80°F, or add 84 BTU/h per 100 CFM of evaporator coil air per degree above 80°F.Capacities at 95°F Outdoor, 75°F DB and 63°F WB IndoorTotal MBTU/h 109.3 Sensible MBTU/h 86.4 Latent MBTU/h 22.9
PRODUCT SPECIFICATIONS
6 www.goodmanmfg.com SS-GCPG10
EXPANDED COOLING DATA
Out
door
Am
bien
t Tem
pera
ture
6575
8595
105
115
Ente
ring
Indo
or W
et B
ulb
Tem
pera
ture
IDB
Airfl
ow
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
70
4500
MB
h11
5.6
119.
813
1.3
-11
2.9
117.
112
8.3
-11
0.3
114.
312
5.2
-10
7.6
111.
512
2.1
-10
2.2
105.
911
6.0
-94
.798
.110
7.5
-
S/T
0.74
0.62
0.43
-0.
770.
640.
45-
0.79
0.66
0.46
-0.
820.
680.
47-
0.85
0.71
0.49
-0.
850.
710.
49-
∆T18
1512
-18
1512
-18
1512
-18
1612
-18
1512
-17
1411
-
Hi P
r24
726
528
0-
277
298
314
-31
533
935
8-
358
386
407
-40
343
445
8-
446
479
506
-
Lo P
r10
611
312
4-
112
120
131
-11
712
413
6-
123
131
143
-12
913
714
9-
133
142
155
-
4000
MB
h11
2.3
116.
412
7.5
-10
9.7
113.
712
4.5
-10
7.0
110.
912
1.6
-10
4.4
108.
211
8.6
-99
.210
2.8
112.
7-
91.9
95.3
104.
4-
S/T
0.71
0.59
0.41
-0.
730.
610.
43-
0.75
0.63
0.44
-0.
780.
650.
45-
0.81
0.67
0.47
-0.
810.
680.
47-
∆T18
1612
-19
1612
-19
1612
-19
1612
-18
1612
-17
1511
-
Hi P
r24
426
327
7-
274
295
311
-31
233
535
4-
355
382
403
-39
943
045
4-
441
475
501
-
Lo P
r10
511
212
2-
111
118
129
-11
612
313
4-
122
129
141
-12
713
514
8-
132
140
153
-
3200
MB
h10
3.6
107.
411
7.7
-10
1.2
104.
911
4.9
-98
.810
2.4
112.
2-
96.4
99.9
109.
5-
91.6
94.9
104.
0-
84.8
87.9
96.3
-
S/T
0.68
0.57
0.40
-0.
710.
590.
41-
0.73
0.61
0.42
-0.
750.
630.
43-
0.78
0.65
0.45
-0.
780.
660.
45-
∆T20
1813
-21
1814
-21
1814
-21
1814
-20
1813
-19
1713
-
Hi P
r23
725
526
9-
266
286
302
-30
232
534
3-
344
370
391
-38
741
744
0-
428
460
486
-
Lo P
r10
210
911
9-
108
115
125
-11
211
913
0-
118
125
137
-12
413
114
3-
128
136
148
-
75
4500
MB
h11
7.6
121.
113
1.0
140.
611
4.9
118.
312
8.0
137.
411
2.1
115.
412
5.0
134.
110
9.4
112.
612
1.9
130.
810
3.9
107.
011
5.8
124.
396
.399
.110
7.3
115.
1
S/T
0.84
0.76
0.57
0.37
0.88
0.78
0.59
0.38
0.90
0.80
0.61
0.39
0.93
0.83
0.63
0.40
0.96
0.86
0.65
0.42
0.97
0.87
0.66
0.42
∆T20
1915
1121
1916
1121
1916
1121
1916
1120
1915
1119
1814
10
Hi P
r24
926
828
329
528
030
131
833
131
834
236
137
736
239
041
142
940
743
846
348
345
048
451
153
3
Lo P
r10
711
412
513
311
412
113
214
011
812
613
714
612
413
214
415
313
013
815
116
113
414
315
616
6
4000
MB
h11
4.2
117.
512
7.2
136.
611
1.5
114.
812
4.3
133.
410
8.9
112.
112
1.3
130.
210
6.2
109.
311
8.4
127.
010
0.9
103.
911
2.4
120.
793
.596
.210
4.2
111.
8
S/T
0.81
0.72
0.55
0.35
0.84
0.75
0.57
0.36
0.86
0.77
0.58
0.37
0.88
0.79
0.60
0.38
0.92
0.82
0.62
0.40
0.93
0.83
0.63
0.40
∆T21
1916
1121
2016
1121
2016
1122
2016
1121
2016
1120
1815
10
Hi P
r24
726
528
029
227
729
831
532
831
533
935
837
335
838
640
742
540
343
445
847
844
648
050
652
8
Lo P
r10
611
312
413
211
212
013
113
911
712
413
614
512
313
114
315
212
913
714
915
913
314
215
516
5
3200
MB
h10
5.4
108.
511
7.4
126.
010
2.9
106.
011
4.7
123.
110
0.5
103.
411
2.0
120.
298
.010
0.9
109.
211
7.2
93.1
95.9
103.
811
1.4
86.3
88.8
96.1
103.
2
S/T
0.78
0.69
0.53
0.34
0.81
0.72
0.55
0.35
0.83
0.74
0.56
0.36
0.85
0.76
0.58
0.37
0.88
0.79
0.60
0.39
0.89
0.80
0.60
0.39
∆T24
2218
1224
2218
1224
2218
1224
2218
1324
2218
1222
2017
12
Hi P
r23
925
727
228
426
828
930
531
830
532
934
736
234
837
439
541
239
142
144
546
443
246
549
151
2
Lo P
r10
311
012
012
810
911
612
713
511
312
113
214
011
912
713
814
712
513
314
515
412
913
715
016
0
IDB
= E
nter
ing
Indo
or D
ry B
ulb
Tem
pera
ture
Des
ign
Sup
erhe
at 7
±2 °
F, D
esig
n S
ubco
olin
g 12
±2
°F p
ress
ures
mea
sure
d @
the
suct
ion
and
liqui
d ac
cess
fi tti
ngs;
AR
I 95°
test
con
ditio
nsH
igh
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
suct
ion
serv
ice
acce
ss fi
tting
s.S
hade
d ar
ea re
fl ect
s A
CC
A (T
VA) c
ondi
tions
PRODUCT SPECIFICATIONS
SS-GCPG10 www.goodmanmfg.com 7
EXPANDED COOLING DATA (CONT.)O
utdo
or A
mbi
ent T
empe
ratu
re65
7585
9510
511
5En
terin
g In
door
Wet
Bul
b Te
mpe
ratu
reID
BA
irfl o
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
4500
MB
h11
9.7
122.
313
0.7
139.
711
6.9
119.
412
7.6
136.
411
4.1
116.
612
4.6
133.
211
1.3
113.
812
1.5
129.
910
5.8
108.
111
5.5
123.
498
.010
0.1
107.
011
4.3
S/T
0.93
0.87
0.71
0.53
0.96
0.90
0.73
0.55
1.00
0.92
0.75
0.56
1.00
0.95
0.78
0.58
1.00
1.00
0.81
0.60
1.00
1.00
0.81
0.61
∆T23
2219
1523
2219
1523
2219
1523
2219
1522
2219
1520
2018
14
Hi P
r25
227
128
629
828
230
432
133
532
134
636
538
136
639
441
643
341
144
346
848
845
548
951
753
9
Lo P
r10
911
612
613
411
512
213
314
211
912
713
814
712
513
314
515
513
114
015
216
213
614
415
816
8
4000
MB
h11
6.2
118.
712
6.9
135.
611
3.5
116.
012
3.9
132.
411
0.8
113.
212
1.0
129.
310
8.1
110.
411
8.0
126.
110
2.7
104.
911
2.1
119.
895
.197
.210
3.8
111.
0
S/T
0.88
0.83
0.67
0.50
0.92
0.86
0.70
0.52
0.94
0.88
0.72
0.54
0.97
0.91
0.74
0.55
1.00
0.94
0.77
0.57
1.00
0.95
0.77
0.58
∆T24
2320
1624
2320
1624
2320
1624
2320
1624
2320
1622
2118
15
Hi P
r24
926
828
329
528
030
131
833
131
834
236
137
736
239
041
242
940
743
846
348
345
048
451
153
3
Lo P
r10
711
412
513
311
412
113
214
011
812
613
714
612
413
214
415
313
013
815
116
113
414
315
616
6
3200
MB
h10
7.2
109.
611
7.1
125.
210
4.8
107.
011
4.4
122.
310
2.3
104.
511
1.6
119.
399
.810
1.9
108.
911
6.4
94.8
96.8
103.
511
0.6
87.8
89.7
95.8
102.
5
S/T
0.85
0.80
0.65
0.49
0.88
0.83
0.67
0.50
0.91
0.85
0.69
0.52
0.93
0.88
0.71
0.53
0.97
0.91
0.74
0.55
0.98
0.92
0.75
0.56
∆T26
2522
1727
2522
1827
2522
1827
2622
1826
2522
1825
2421
16
Hi P
r24
226
027
528
627
129
230
832
130
833
235
036
635
137
839
941
639
542
544
946
843
747
049
651
7
Lo P
r10
411
112
112
911
011
712
813
611
412
213
314
212
012
814
014
912
613
414
615
613
013
915
116
1
85
4500
MB
h12
1.8
124.
113
0.0
138.
711
8.9
121.
212
7.0
135.
511
6.1
118.
412
4.0
132.
211
3.3
115.
512
0.9
129.
010
7.6
109.
711
4.9
122.
699
.710
1.6
106.
411
3.5
S/T
0.97
0.94
0.85
0.69
1.00
0.97
0.88
0.71
1.00
1.00
0.90
0.73
1.00
1.00
0.93
0.75
1.00
1.00
0.96
0.78
1.00
1.00
0.97
0.79
∆T24
2422
1924
2423
2024
2423
2023
2423
2022
2223
2020
2121
18
Hi P
r25
427
328
930
128
530
732
433
832
434
936
938
436
939
842
043
841
644
747
249
345
949
452
254
4
Lo P
r11
011
712
713
611
612
313
514
312
012
814
014
912
613
514
715
613
314
115
416
413
714
615
917
0
4000
MB
h11
8.2
120.
512
6.2
134.
711
5.5
117.
712
3.3
131.
511
2.7
114.
912
0.3
128.
411
0.0
112.
111
7.4
125.
310
4.5
106.
511
1.5
119.
096
.898
.710
3.3
110.
2
S/T
0.93
0.89
0.81
0.65
0.96
0.93
0.84
0.68
0.98
0.95
0.86
0.70
1.00
0.98
0.89
0.72
1.00
1.00
0.92
0.75
1.00
1.00
0.93
0.75
∆T25
2523
2025
2524
2126
2524
2125
2524
2124
2424
2022
2322
19
Hi P
r25
227
128
629
828
230
432
133
532
134
636
538
136
639
441
643
341
144
346
848
845
548
951
753
9
Lo P
r10
911
612
613
411
512
213
314
211
912
713
814
712
513
314
515
513
114
015
216
213
614
415
816
8
3200
MB
h10
9.1
111.
211
6.5
124.
310
6.6
108.
611
3.8
121.
410
4.0
106.
111
1.1
118.
510
1.5
103.
510
8.4
115.
696
.498
.310
3.0
109.
889
.391
.195
.410
1.7
S/T
0.89
0.86
0.78
0.63
0.93
0.89
0.81
0.65
0.95
0.92
0.83
0.67
0.98
0.95
0.85
0.69
1.00
0.98
0.89
0.72
1.00
0.99
0.89
0.72
∆T28
2826
2328
2826
2328
2826
2329
2827
2328
2826
2326
2624
21
Hi P
r24
426
327
728
927
429
531
132
531
133
535
436
935
538
240
342
039
943
045
447
344
147
550
152
3
Lo P
r10
511
212
213
011
111
812
913
811
612
313
414
312
112
914
115
012
713
514
815
713
214
015
316
3
IDB
= E
nter
ing
Indo
or D
ry B
ulb
Tem
pera
ture
Des
ign
Sup
erhe
at 7
±2 °
F, D
esig
n S
ubco
olin
g 12
±2
°F p
ress
ures
mea
sure
d @
the
suct
ion
and
liqui
d ac
cess
fi tti
ngs;
AR
I 95°
test
con
ditio
ns
Hig
h an
d lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ctio
n ac
cess
fi tti
ngs.
Sha
ded
area
refl e
cts
AR
I Rat
ing
cond
ition
s
PRODUCT SPECIFICATIONS
8 www.goodmanmfg.com SS-GCPG10
DIMENSIONS
ABCD
F
E
I
G
H
J
KL
M
N O PQ
R
S
T
U
V
Downflow Horizontal
W
X Y
Z
Point Dimension(”) Point Dimension
(”)A 3½ N 28⅜B 4½ O 7⅜C 12⅝ P 12⅝D 285/16 Q 5⅞E 4 R 1¾F 54¾ S 36⅜G 3 T 5 H 14 U 15½I 9215/16 V 13⅞J 36⅜ W 4½K 48⅜ X 99¾L 52⅞ Y 99⅛M 613/16 Z 61
PRODUCT SPECIFICATIONS
SS-GCPG10 www.goodmanmfg.com 9
UNIT CLEARANCES
ELECTRICAL ENTRANCE LOCATIONS
11⅝”
103/16”
3¾”
Low-Voltage Entrance
High-Voltage Entrance
Dimples Mark Drill Locations
Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48” on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airfl ow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake.
48”
36” Min.
48”
48”75”
PRODUCT SPECIFICATIONS
10 www.goodmanmfg.com SS-GCPG10
ROOF CURB INSTALLATION — RIGGING
Provisions for forks have been included in the unit base frame. No other fork locations are approved.
Unit must be lifted by the four lifting holes located at the base frame corners.Lifting cables should be attached to the unit with shackles.The distance between the crane hook and the top of the unit must not be less than 60”.Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of suffi cient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to pro-tect unit base frame from fork lift damage. To remove the struts, ex-tract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit.
Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual.Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofi ng Contractors Association Manual.Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end.Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct.
•
••
•
To assist in determining rigging requirements, unit weights are shown to the right.Note: These weights are calculated without accessories installed.
Corner & Center-of-Gravity Locations
36”
Compressor 1
Return
Evaporator Coil
SupplyCompressor 2
55”
Data Weight(lbs)
Weight A 230Weight B 330Weight C 280Weight D 405Shipping Weight 1275Operating Weight 1235
PRODUCT SPECIFICATIONS
SS-GCPG10 www.goodmanmfg.com 11
ROOF CURB INSTALLATION (CONT.)Curb installations must comply with local codes and should follow the established guidelines of the National Roofi ng Contractors Association.Proper unit installation requires that the roof curb be fi rmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb.Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for fi eld assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package.
Determine suffi cient structural support before locating and mounting the curb and package unit.Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory.
•
•
Contractor furnishes curb insulation, cant strips, fl ashing, and general roofi ng material.Support curbs on parallel sides with roof mem-bers. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings.
Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended.See the manual shipped with the roof curb for assembly and installation instructions.
•
•
TOP VIEW
3-D VIEW
15⅜ x 31⅛Supply Opening
14⅝ x 38⅜Return Opening
92¼ 53¼
14
1⅝¾
14
1⅜
POWER AND LOW-VOLTAGE BLOCK LOCATIONS
Power Wiring
ThermostatWiring
PRODUCT SPECIFICATIONS
12 www.goodmanmfg.com SS-GCPG10
WIRING DIAGRAM — CPG120*3B** (THREE-PHASE BELT DRIVE)
PRODUCT SPECIFICATIONS
SS-GCPG10 www.goodmanmfg.com 13
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date information.
WIRING DIAGRAM — CPG120*3B** (THREE-PHASE BELT DRIVE) CONT.
PRODUCT SPECIFICATIONS
14 www.goodmanmfg.com SS-GCPG10
WIRING DIAGRAM — CPG120*4B/7B** (460V / 575V BELT DRIVE)
PRODUCT SPECIFICATIONS
SS-GCPG10 www.goodmanmfg.com 15
WIRING DIAGRAM — CPG120*4B/7B** (460V / 575V BELT DRIVE) CONT.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date information.
PRODUCT SPECIFICATIONS
16 www.goodmanmfg.com SS-GCPG10
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifi cations
or designs without notice or without incurring obligations.Copyright © 2008 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
ACCESSORIES
Item # Description Package Dimensions (“)
Ship Weight
14CURB90150 Roof Curb — 14” Tall 16 x 6 x 94 18025FD90150 25% Manual Fresh-Air Damper 13 x 15½ x 40 1125MFD90150 25% Motorized Fresh-Air Damper 13 x 15½ x 40 12CDK120 Concentric Duct Kit 31 x 48 x 18 55CDK90102 Concentric Duct Kit 31 x 48 x 18 55DNECONGS90150 Downfl ow Economizer 40 x 20 x 41 135HailGD02 Condenser Coil Hail Guard 64 x 52 x 2HAKT36300 High-Altitude KitHSKT120 High Static KitHZECONGS90150 Horizontal Economizer 22 x 20 x 48 110LPKT36150 LP Conversion Kit