c:programdataautodeskrvt 2017librariesaustraliawebsite ... · slab edge to remain above finished...

9
CLIENT: PROJECT: DRAWING NAME: SCALE @ A3 PROPOSED RESIDENCE FOR PAGE NO: OF 09 PLAN NUMBER: DRAWN: CHECKED: DATE: M: 0419 786 578 M: 0403 508 705 E: [email protected] USE SCALE & RULER AS A GUIDE ONLY AREI DESIGNS AT NTS BEN DYE BEN DYE LOT 116 AREI CRESCENT AUGUSTA AREI DESIGNS W: areidesigns.com.au ABN: 31614195818 QBCC LIC: 15040397 C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED AREI PLAN CODE: COVER 01 A001-17 01/01/17 SERIES 3 ASC1 PAGE LIST PAGE NO PAGE TITLE 01 COVER 02 SITE PLAN 03 FLOOR PLAN 04 3D VIEWS 05 ELEVATIONS 06 CROSS SECTION 07 FOUNDATION PLAN 08 ELECTRICAL & FIXTURES PLAN 09 ROOF DRAINAGE REV. REVISION DESCRIPTION APPROV. DATE A CONSTRUCTION ISSUE 01/01/17 GENERAL NOTES: 1. ALL DESIGN, CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH: THE CURRENT NATIONAL CONSTRUCTION CODES (NCC) THE QUEENSLAND DEVELOPMENT CODE (QDC) BUILDING REGULATIONS CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURERS SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED 2. THESE PLANS ARE TO BE READ IN CONJUNCTION WITH CONTRACT DOCUMENTS AND ENGINEERS DRAWINGS AND SPECIFICATIONS. RESPONSIBLE PARTIES ARE TO BE NOTIFIED OF ANY DISCREPANCIES. 3. SUBSTITUTION OF ANY STRUCTURAL MEMBERS & OR VARIATIONS TO ANY PART OF THE DESIGN WILL VOID ANY RESPONSIBILITIES OF THE BUILDING DESIGNER FOR THE STRUCTURAL INTEGRITY & PERFORMANCE OF THE BUILDING. 4. 3D VIEWS, PERSPECTIVES AND ILLUSTRATIONS ARE INTENDED TO BE A VISUAL AID ONLY, THEY ARE NOT PRESCRIPTIVE BUT INDICATIVE ONLY. THE IMAGES ARE NOT TO BE RELIED UPON IN ANY WAY FOR FINAL CONSTRUCTION FINISHES AND RESULTS. 5. ALL DIMENSIONS IN MILLIMETERS. 6. DIMENSIONS TAKE PREFERENCE TO SCALE AND ARE TO STRUCTURE NOT FINISH ON NEW WORK. EXISTING WALLS MAY BE NOMINALLY DIMENSIONED. 7. ALL DIMENSIONS, DETAILS, SITE LEVELS AND FINISHED FLOOR LEVELS TO BE CONFIRMED BY CONTRACTOR BEFORE COMMENCEMENT OF ANY CONSTRUCTION AND RESPONSIBLE PEOPLE NOTIFIED OF ANY DISCREPANCIES. 8. MANUFACTURER'S SPECIFICATION MEANS A CURRENT APPROVED SPECIFICATION FOR USE UNDER THE CONDITIONS APPLICABLE THESE DRAWINGS ARE AVAILABLE DIGITALLY, IF REQUIRED. 9. ANY DATA SUPPLIED BY OTHERS AND SHOWN ON THESE DRAWINGS ARE NOT THE RESPONSIBILITY OF THIS DESIGNER. ALL USERS OF THESE DRAWINGS ARE ADVISED TO CHECK OTHER SUPPLIED DATA. 10. OWNER REMAINS RESPONSIBLE FOR ONGOING MAINTENANCE OF BUILDING. STRUCTURAL ELEMENTS IN PARTICULAR ARE TO REMAIN PROTECTED BY THE METHODS SHOWN AND LISTED IN THESE DRAWINGS. ROOF DRAINAGE NOTES: 1. ALL GUTTER AND DOWNPIPE WORKS TO AS/NZS 3500.3 AND CURRENT NCC VOLUME 2 PART 3.5.2. 2. DOWNPIPES (DP) TO BE 100mmØ UPVC. 3. TEMPORARY DOWNPIPES TO BE PROVIDED AT DP LOCATIONS DURING CONSTRUCTION DRAINING ROOFWATER ONTO GROUND, 2M MIN AWAY FROM BUILDING. 4. ALL STORMWATER, DOWN PIPES, RAIN WATER TANKS & SITE DRAINAGE TO BE SIZED & LOCATED BY THE HYDRAULIC CONSULTANT/ PLUMBER IN ACCORDANCE WITH NCC VOL. 2.3.1.2 & 3.5.2 AND QDC MP4.2/ LOCAL PLANNING SCHEME HOUSE CODE AND AS 3500 ALL PARTS. 5. THE ROOF DRAINAGE SYSTEM MUST BE PROVIDED WITH AN OVERFLOW TO PREVENT THE BACKFLOW OF WATER INTO THE BUILDING. 6. THE AREA SPECIFIC RAINFALL INTENSITY MUST BE SELECTED FROM NCC TABLE 3.5.2.1 OR FROM AS/NZ3500. 7. EAVES GUTTERS MUST BE INSTALLED AT A FALL NOT LESS THAN 1 IN 500 WITH SUPPORT BRACKETS AT 1.2m MAXIMUM CENTRES. 8. BOX GUTTERS MUST BE INSTALLED AT A FALL NOT LESS THAN 1 IN 100 IN ACCORDANCE WITH AS/NZ3500.3. 9. DOWNPIPES MUST SERVE NOT MORE THAN 12 METERS OF GUTTER LENGTH FOR EACH DOWNPIPE WHICH MUST BE LOCATED AS CLOSE AS POSSIBLE TO VALLEY GUTTERS. EAVES GUTTERS MUST BE PROVIDED WITH AN OVERFLOW SYSTEM WHERE DOWNPIPES ARE LOCATED MORE THAN 1.2 METRES FROM A VALLEY GUTTER. 10. DOWNPIPES (DP) TO BE MAX. 12m LINEAL APART. DP Ø GUTTER MAX ROOF AREA 100mm MIN. 7900mm² MIN 35m² CROSS SECT. AREA SITE WORKS NOTES: 1. POSITION OF DWELLING TO BE CONFIRMED BY SURVEYOR & CLIENT PRIOR TO ANY SITE WORKS. 2. ALL STORMWATER, DOWN PIPES, RAIN WATER TANKS & SITE DRAINAGE TO BE SIZED & LOCATED BY THE HYDRAULIC CONSULTANT/ PLUMBER IN ACCORDANCE WITH NCC VOL. 2.3.1.2 & 3.5.2 AND QDC MP4.2/ LOCAL PLANNING SCHEME HOUSE CODE AND AS 3500 ALL PARTS. 3. BUILDER TO ENSURE THAT ACTUAL SEWER LINE AND MANHOLE POSITIONS MATCH THOSE AS SHOWN AS BASED ON LOCAL AUTHORITY DOCUMENTS. ANY DISCREPANCIES MUST BE BROUGHT TO ATTENTION AND RESOLVED PRIOR TO COMMENCEMENT OF CONSTRUCTION. 4. BUILDER TO DETERMINE APPROPRIATE PLATFORMING METHOD ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS. FINISHED FLOOR LEVEL IS TO BE ABOVE THE MINIMUM LEVEL AS PER LOCAL AUTHORITIES REQUIREMENTS & TO COMPLY WITH NCC VOL. 2.3.1.2.3. 5. FALL OF LAND UNKNOWN AND IS TO BE CONFIRMED ON SITE BEFORE COMMENCEMENT OF CONSTRUCTION. ANY REQUIRED EARTHWORKS INCLUDING CUT, FILL, BATTERS AND RETAINING MUST COMPLY WITH THE CURRENT NCC VOLUME 2 3.1.1, AS 3798 & AS 4200. 6. THE FINISHED SURFACE IMMEDIATELY SURROUNDING THE DWELLING, 1000mm WIDE, IS TO FALL AWAY FROM THE DWELLING AT A SLOPE OF 1 IN 20 MINIMUM. 7. STORMWATER MUST BE CONNECTED TO A LEGAL POINT OF DISCHARGE - STORMWATER KERB ADAPTERS TO STREET (2 MAX.) ROOFWATER/STORMWATER PIPE BUBBLERS TO COUNCIL SPECIFICATION. RAINWATER TANK, OVERFLOW MUST CONNECT TO STORMWATER SYSTEM. 8. SURFACE DRAINAGE IS TO DISCHARGE EVENLY WITHIN THE SITE AND WITHOUT NUISANCE TO ADJOINING PROPERTIES. 9. ALL SUB-FLOOR AREAS MUST BE GRADED TO AVOID THE PONDING OF WATER. 10. THE HEIGHT OF FENCES, INCLUDING THE HEIGHT OF RETAINING WALLS ARE NOT TO EXCEED 2.0m ABOVE FINISHED GROUND LEVEL ONLY IF INDICATED ON THE PLANS AND TO LOCAL AUTHORITY APPROVAL. 11. WHERE SERVICES / PIPEWORK ARE LOCATED UNDER DRIVEWAYS AND SLABS CONTRACTORS ARE TO ENSURE ADEQUATE COMPACTION TO TRENCH BACKFILL IS ACHIEVED TO SUPPORT CONCRETE. PATH/DRIVEWAY NOTES: 1. DRIVEWAY SLOPE NOT TO EXCEED 1:4. CHECK WITH LOCAL AUTHORITY REQUIREMENTS PRIOR TO CONSTRUCTING ANY DRIVEWAYS, PATHWAYS OR CROSSOVERS BETWEEN THE PROPERTY BOUNDARY AND ROAD KERB. 2. PROVIDE A LAYER OF SAND A MINIMUM OF 20mm THICK UNDER THE SLAB, COMPACTED AND LEVELED. 3. SLAB THICKNESS, MESH TO ENGINEERS DESIGN. TERMITE RISK NOTES: 1. TERMITE CONTROL BARRIERS TO BE IN ACCORDANCE WITH AS 3660.1 AND NCC CLAUSE 3.1.3. 2. ANY UNTREATED TIMBER POSTS, STAIRS AND THE LIKE SHALL BE SET 75MM MINIMUM CLEAR OF GROUND FOR VISUAL TERMITE CONTROL. 3. TWO APPROVED NOTICES SHALL BE AFFIXED TO THE DWELLING AS REQUIRED ADVISING OWNERS OF THE METHOD OF TERMITE RISK MANAGEMENT USED, AND THEIR ONGOING RESPONSIBILITY FOR THE MAINTENANCE OF THE SYSTEMS. 4. BUILDER TO CONFIRM WITH OWNER THE CHOSEN METHOD OF TIMBER PROTECTION. 5. OWNER REMAINS RESPONSIBLE FOR ONGOING INSPECTION OF STRUCTURAL TIMBER ELEMENTS, AND THAT BARRIERS ARE NOT COMPROMISED. 6. WHERE CONCRETE SLAB FORMS BARRIER, SLAB TO BE CONSTRUCTED AS PER AS2870. SLAB & FOOTINGS TO BE "MONOLITHIC". TERMIMESH FLANGE TO BE CLAMPED TO PIPES AND SET IN SLAB. 75MM MIN OF EXPOSED SLAB EDGE TO REMAIN ABOVE FINISHED PERIMETER LEVEL. EXPOSED EDGE NOT TO BE COVERED BY SOIL, RENDERED OR TILED, BUT MAY BE PAINTED. WHERE BRICKWORK CONCEALS EDGE OF SLAB, IN ADDITION TO ABOVE, PROVIDE TERMIMESH BARRIER BELOW D.P.C. FIXED TO SLAB EDGE. 7. INSTALL ANT CAPPING TO ALL BRICK PIERS, TIMBER OR CONC STUMPS. KEEP TIMBER CLEAR OF GROUND WHEN ON STEEL ANCHORS. NON-TIMBER ELEMENTS (EG STEEL POSTS) NEED NO PROTECTION FROM TERMITES. 8. ALL TIMBER IN DIRECT CONTACT WITH CONC TO BE SEPARATED BY G.I. FLASHING. FLOOR PLAN NOTES: 1. SMOKE ALARMS TO BE INSTALLED IN ACCORDANCE WITH THE NCC PART 3.7.2 - SMOKE ALARMS. SMOKE ALARMS MUST COMPLY WITH AS3786. ONLY USE PHOTOELECTRIC TYPE SMOKE ALARMS ALL SMOKE ALARMS TO BE INTERCONNECTED INSTALL LOCATIONS: 1. ON EACH LEVEL OF LIVING SPACE 2. OUTSIDE EACH BEDROOM AREA 3. IN EVERY BEDROOM 2. WALL FINISHES AND WINDOW TYPES ON 3D VIEWS ARE INDICATIVE ONLY AND ARE NOT PRESCRIPTIVE. 3. BUILDER TO CONFIRM ALL DIMENSIONS PRIOR TO CONSTRUCTION. DIMENSIONS ARE TO FRAME ONLY AND DO NOT INCLUDE CLADDING/LININGS (UNO). 4. S.S. BALUSTRADING TO COMPLY WITH CURRENT NCC VOLUME 2 SECTION 3.9.2.3 'WIRE BALUSTRADING CONSTRUCTION' 5. DOORS TO W.C.'S TO HAVE LIFT OFF HINGES (ONLY IF THE DOORS SWING IN TOWARDS THE W.C). 6. MASONRY CONSTRUCTION TO AS 3700. 7. REFER ENGINEERS DRAWINGS & SPECIFICATIONS FOR ALL STRUCTURAL DETAILS, FRAMING, BRACING, TIE DOWN AND SLAB/FOOTING DETAILS. 8. SEAL WET AREAS IN ACCORDANCE WITH AS3740 & NCC REQUIREMENTS. 9. PROVIDE FLOOR WASTE TO ALL WET AREAS. 3D VIEW NOTES: 1. GROUND LINE OR SLOPE OF SITE IS NOT REPRESENTED ON 3D VIEWS. 2. FURNITURE AND FIXTURES ARE INDICATIVE ONLY AND ARE NOT PRESCRIPTIVE. 3. 3D VIEWS, PERSPECTIVES AND ILLUSTRATIONS ARE INTENDED TO BE A VISUAL AID ONLY, THEY ARE NOT PRESCRIPTIVE BUT INDICATIVE ONLY. THE IMAGES ARE NOT TO BE RELIED UPON IN ANY WAY FOR FINAL CONSTRUCTION FINISHES AND RESULTS. ELEVATION NOTES: 1. WALL FINISHES AND WINDOW TYPES ARE INDICATIVE ONLY AND ARE NOT PRESCRIPTIVE. REFER TO BUILDERS SPECIFICATIONS FOR DETAILS. 2. GROUND LINE SHOWN ON ELEVATIONS DOES NOT RELATE TO ACTUAL SLOPE OF SITE. 3. FURNITURE AND FIXTURES ARE INDICATIVE ONLY AND ARE NOT PRESCRIPTIVE. 4. ELEVATIONS ARE INTENDED TO BE A VISUAL AID ONLY, THEY ARE NOT PRESCRIPTIVE BUT INDICATIVE ONLY. THE IMAGES ARE NOT TO BE RELIED UPON IN ANY WAY FOR FINAL CONSTRUCTION FINISHES AND RESULTS. SECTION NOTES: 1. TRUSS DESIGN IS INDICATIVE ONLY AND IS NOT PRESCRIPTIVE. FINAL DESIGN TO TRUSS MANUFACTURER SPECIFICATIONS. 2. ALL PINE TO BE JD4 MIN. 3. ALL HWD. TO BE F14 MIN. 4. GROUND LINE SHOWN DOES NOT RELATE TO ACTUAL SLOPE OF SITE. 5. FURNITURE AND FIXTURES ARE INDICATIVE ONLY AND ARE NOT PRESCRIPTIVE. 6. SECTIONS ARE INTENDED TO BE A VISUAL AID ONLY, THEY ARE NOT PRESCRIPTIVE BUT INDICATIVE ONLY. THE IMAGES ARE NOT TO BE RELIED UPON IN ANY WAY FOR FINAL CONSTRUCTION FINISHES AND RESULTS. FOUNDATION NOTES: 1. THESE PLANS ARE TO BE READ IN CONJUNCTION WITH CONTRACT DOCUMENTS AND ENGINEERS DRAWINGS AND SPECIFICATIONS. RESPONSIBLE PARTIES ARE TO BE NOTIFIED OF ANY DISCREPANCIES. SITE CLASSIFICATION IS TO BE CONFIRMED BY INSPECTION OF FOOTING EXCAVATIONS. 2. PLUMBER RESPONSIBLE TO LOCATE AND CONFIRM SEWER HOUSE CONNECTION LOCATION ACCURATELY PRIOR TO COMMENCEMENT. PLUMBER IS TO VERIFY WITH SITE SUPERVISOR PRIOR TO SETTING OUT FIXTURE DRAINAGE POINTS. NO AMENDMENTS OR SPECIAL FIXTURES HAVE BEEN NOMINATED. 3. WHERE SERVICES / PIPEWORK ARE LOCATED UNDER DRIVEWAYS AND SLABS CONTRACTORS ARE TO ENSURE ADEQUATE COMPACTION TO TRENCH BACKFILL ACHIEVED TO SUPPORT CONCRETE. 4. REBATE GARAGE DOORS & SLIDING GLASS DOORS 20mm, AND SHOWER RECESSES 50mm IN LOCATIONS SHOWN. 5. ACCORDING TO MANUF' SPEC. OR BUILDERS DIRECTIONS. 6. MINIMUM COVER TO GROUND - 50mm. 7. TOP COVER TO SLAB REINFORCEMENT - 30mm. 8. GRADE FINISHED GROUND SURFACE TO DIVERT WATER AWAY FROM BUILDING. 9. WATERPROOF MEMBRANE IS 0.2mm POLYETHYLENE. JOINTS ARE TO BE LAPPED 300mm AND TAPED. 10. REINFORCEMENT TO BE SUPPORTED ON PLASTIC CHAIRS AT 1000mm CRS. 11. ALL CONCRETE IS TO BE MECHANICALLY VIBRATED DURING PLACING. 12. FILL MATERIAL AND SAND UNDER SLABS IS TO BE COMPACTED TO 95% OF MAX. DRY DENSITY. 13. FLOORS TO ALL WET AREAS TO HAVE A FALL TO A FLOOR WASTE. ELECTRICAL NOTES: 1. SMOKE ALARMS TO BE INSTALLED IN ACCORDANCE WITH THE NCC PART 3.7.2 - SMOKE ALARMS. SMOKE ALARMS MUST COMPLY WITH AS 3786. ONLY USE PHOTOELECTRIC TYPE SMOKE ALARMS ALL SMOKE ALARMS TO BE INTERCONNECTED INSTALL LOCATIONS: 1. ON EACH LEVEL OF LIVING SPACE 2. OUTSIDE EACH BEDROOM AREA 3. IN EVERY BEDROOM 2. THIS PLAN IS INDICATIVE ONLY AND IS TO BE USED ONLY AS AN EXAMPLE. OWNERS TO NOMINATE FINAL POSITIONS OF ELECTRICAL APPLIANCES, LIGHTING AND ELECTRICAL FITTINGS. PROPOSED RESIDENCE FOR AREI DESIGNS CONSTRUCTION DRAWINGS ADDRESS LOT 116 AREI CRESCENT AUGUSTA EXAMPLE PLAN ONLY

Upload: others

Post on 26-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • CLIENT: PROJECT:

    DRAWING NAME:SCALE @ A3

    PROPOSED RESIDENCE FOR

    PAGE NO:OF 09

    PLAN NUMBER:

    DRAWN:

    CHECKED:

    DATE:

    M: 0419 786 578M: 0403 508 705E: [email protected]

    USE SCALE & RULER AS A GUIDE ONLYAREI DESIGNS AT

    NTS BEN DYE

    BEN DYELOT 116 AREI CRESCENT

    AUGUSTA

    AREI DESIGNS

    W: areidesigns.com.auABN: 31614195818QBCC LIC: 15040397

    C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED

    AREI PLAN CODE:

    COVER

    01A001-17

    01/01/17

    SERIES 3 ASC1

    PAGE LIST

    PAGE NO PAGE TITLE

    01 COVER

    02 SITE PLAN

    03 FLOOR PLAN

    04 3D VIEWS

    05 ELEVATIONS

    06 CROSS SECTION

    07 FOUNDATION PLAN

    08 ELECTRICAL & FIXTURES PLAN

    09 ROOF DRAINAGE

    REV. REVISION DESCRIPTION APPROV. DATE

    A CONSTRUCTION ISSUE 01/01/17

    GENERAL NOTES:

    1. ALL DESIGN, CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH:• THE CURRENT NATIONAL CONSTRUCTION

    CODES (NCC)• THE QUEENSLAND DEVELOPMENT CODE

    (QDC)• BUILDING REGULATIONS• CURRENT ISSUES OF AUSTRALIAN

    STANDARDS & MANUFACTURERS SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED

    2. THESE PLANS ARE TO BE READ IN CONJUNCTION WITH CONTRACT DOCUMENTS AND ENGINEERS DRAWINGS AND SPECIFICATIONS. RESPONSIBLE PARTIES ARE TO BE NOTIFIED OF ANY DISCREPANCIES.

    3. SUBSTITUTION OF ANY STRUCTURAL MEMBERS & OR VARIATIONS TO ANY PART OF THE DESIGN WILL VOID ANY RESPONSIBILITIES OF THE BUILDING DESIGNER FOR THE STRUCTURAL INTEGRITY & PERFORMANCE OF THE BUILDING.

    4. 3D VIEWS, PERSPECTIVES AND ILLUSTRATIONS ARE INTENDED TO BE A VISUAL AID ONLY, THEY ARE NOT PRESCRIPTIVE BUT INDICATIVE ONLY. THE IMAGES ARE NOT TO BE RELIED UPON IN ANY WAY FOR FINAL CONSTRUCTION FINISHES AND RESULTS.

    5. ALL DIMENSIONS IN MILLIMETERS.6. DIMENSIONS TAKE PREFERENCE TO SCALE AND

    ARE TO STRUCTURE NOT FINISH ON NEW WORK. EXISTING WALLS MAY BE NOMINALLY DIMENSIONED.

    7. ALL DIMENSIONS, DETAILS, SITE LEVELS AND FINISHED FLOOR LEVELS TO BE CONFIRMED BY CONTRACTOR BEFORE COMMENCEMENT OF ANY CONSTRUCTION AND RESPONSIBLE PEOPLE NOTIFIED OF ANY DISCREPANCIES.

    8. MANUFACTURER'S SPECIFICATION MEANS A CURRENT APPROVED SPECIFICATION FOR USE UNDER THE CONDITIONS APPLICABLE THESE DRAWINGS ARE AVAILABLE DIGITALLY, IF REQUIRED.

    9. ANY DATA SUPPLIED BY OTHERS AND SHOWN ON THESE DRAWINGS ARE NOT THE RESPONSIBILITY OF THIS DESIGNER. ALL USERS OF THESE DRAWINGS ARE ADVISED TO CHECK OTHER SUPPLIED DATA.

    10. OWNER REMAINS RESPONSIBLE FOR ONGOING MAINTENANCE OF BUILDING. STRUCTURAL ELEMENTS IN PARTICULAR ARE TO REMAIN PROTECTED BY THE METHODS SHOWN AND LISTED IN THESE DRAWINGS.

    ROOF DRAINAGE NOTES:

    1. ALL GUTTER AND DOWNPIPE WORKS TO AS/NZS 3500.3 AND CURRENT NCC VOLUME 2 PART 3.5.2.

    2. DOWNPIPES (DP) TO BE 100mmØ UPVC.3. TEMPORARY DOWNPIPES TO BE PROVIDED AT DP

    LOCATIONS DURING CONSTRUCTION DRAINING ROOFWATER ONTO GROUND, 2M MIN AWAY FROM BUILDING.

    4. ALL STORMWATER, DOWN PIPES, RAIN WATER TANKS & SITE DRAINAGE TO BE SIZED & LOCATED BY THE HYDRAULIC CONSULTANT/ PLUMBER IN ACCORDANCE WITH NCC VOL. 2.3.1.2 & 3.5.2 AND QDC MP4.2/ LOCAL PLANNING SCHEME HOUSE CODE AND AS 3500 ALL PARTS.

    5. THE ROOF DRAINAGE SYSTEM MUST BE PROVIDED WITH AN OVERFLOW TO PREVENT THE BACKFLOW OF WATER INTO THE BUILDING.

    6. THE AREA SPECIFIC RAINFALL INTENSITY MUST BE SELECTED FROM NCC TABLE 3.5.2.1 OR FROM AS/NZ3500.

    7. EAVES GUTTERS MUST BE INSTALLED AT A FALL NOT LESS THAN 1 IN 500 WITH SUPPORT BRACKETS AT 1.2m MAXIMUM CENTRES.

    8. BOX GUTTERS MUST BE INSTALLED AT A FALL NOT LESS THAN 1 IN 100 IN ACCORDANCE WITH AS/NZ3500.3.

    9. DOWNPIPES MUST SERVE NOT MORE THAN 12 METERS OF GUTTER LENGTH FOR EACH DOWNPIPE WHICH MUST BE LOCATED AS CLOSE AS POSSIBLE TO VALLEY GUTTERS. EAVES GUTTERS MUST BE PROVIDED WITH AN OVERFLOW SYSTEM WHERE DOWNPIPES ARE LOCATED MORE THAN 1.2 METRES FROM A VALLEY GUTTER.

    10. DOWNPIPES (DP) TO BE MAX. 12m LINEAL APART.DP Ø GUTTER MAX ROOF AREA 100mm MIN. 7900mm² MIN 35m² CROSS SECT. AREA

    SITE WORKS NOTES:

    1. POSITION OF DWELLING TO BE CONFIRMED BY SURVEYOR & CLIENT PRIOR TO ANY SITE WORKS.

    2. ALL STORMWATER, DOWN PIPES, RAIN WATER TANKS & SITE DRAINAGE TO BE SIZED & LOCATED BY THE HYDRAULIC CONSULTANT/ PLUMBER IN ACCORDANCE WITH NCC VOL. 2.3.1.2 & 3.5.2 AND QDC MP4.2/ LOCAL PLANNING SCHEME HOUSE CODE AND AS 3500 ALL PARTS.

    3. BUILDER TO ENSURE THAT ACTUAL SEWER LINE AND MANHOLE POSITIONS MATCH THOSE AS SHOWN AS BASED ON LOCAL AUTHORITY DOCUMENTS. ANY DISCREPANCIES MUST BE BROUGHT TO ATTENTION AND RESOLVED PRIOR TO COMMENCEMENT OF CONSTRUCTION.

    4. BUILDER TO DETERMINE APPROPRIATE PLATFORMING METHOD ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS. FINISHED FLOOR LEVEL IS TO BE ABOVE THE MINIMUM LEVEL AS PER LOCAL AUTHORITIES REQUIREMENTS & TO COMPLY WITH NCC VOL. 2.3.1.2.3.

    5. FALL OF LAND UNKNOWN AND IS TO BE CONFIRMED ON SITE BEFORE COMMENCEMENT OF CONSTRUCTION. ANY REQUIRED EARTHWORKS INCLUDING CUT, FILL, BATTERS AND RETAINING MUST COMPLY WITH THE CURRENT NCC VOLUME 2 3.1.1, AS 3798 & AS 4200.

    6. THE FINISHED SURFACE IMMEDIATELY SURROUNDING THE DWELLING, 1000mm WIDE, IS TO FALL AWAY FROM THE DWELLING AT A SLOPE OF 1 IN 20 MINIMUM.

    7. STORMWATER MUST BE CONNECTED TO A LEGAL POINT OF DISCHARGE -• STORMWATER KERB ADAPTERS TO STREET (2

    MAX.)• ROOFWATER/STORMWATER PIPE• BUBBLERS TO COUNCIL SPECIFICATION.• RAINWATER TANK, OVERFLOW MUST

    CONNECT TO STORMWATER SYSTEM.8. SURFACE DRAINAGE IS TO DISCHARGE EVENLY

    WITHIN THE SITE AND WITHOUT NUISANCE TO ADJOINING PROPERTIES.

    9. ALL SUB-FLOOR AREAS MUST BE GRADED TO AVOID THE PONDING OF WATER.

    10. THE HEIGHT OF FENCES, INCLUDING THE HEIGHT OF RETAINING WALLS ARE NOT TO EXCEED 2.0m ABOVE FINISHED GROUND LEVEL ONLY IF INDICATED ON THE PLANS AND TO LOCAL AUTHORITY APPROVAL.

    11. WHERE SERVICES / PIPEWORK ARE LOCATED UNDER DRIVEWAYS AND SLABS CONTRACTORS ARE TO ENSURE ADEQUATE COMPACTION TO TRENCH BACKFILL IS ACHIEVED TO SUPPORT CONCRETE.

    PATH/DRIVEWAY NOTES:

    1. DRIVEWAY SLOPE NOT TO EXCEED 1:4. CHECK WITH LOCAL AUTHORITY REQUIREMENTS PRIOR TO CONSTRUCTING ANY DRIVEWAYS, PATHWAYS OR CROSSOVERS BETWEEN THE PROPERTY BOUNDARY AND ROAD KERB.

    2. PROVIDE A LAYER OF SAND A MINIMUM OF 20mm THICK UNDER THE SLAB, COMPACTED AND LEVELED.

    3. SLAB THICKNESS, MESH TO ENGINEERS DESIGN.

    TERMITE RISK NOTES:

    1. TERMITE CONTROL BARRIERS TO BE IN ACCORDANCE WITH AS 3660.1 AND NCC CLAUSE 3.1.3.2. ANY UNTREATED TIMBER POSTS, STAIRS AND THE LIKE SHALL BE SET 75MM MINIMUM CLEAR OF GROUND

    FOR VISUAL TERMITE CONTROL.3. TWO APPROVED NOTICES SHALL BE AFFIXED TO THE DWELLING AS REQUIRED ADVISING OWNERS OF THE

    METHOD OF TERMITE RISK MANAGEMENT USED, AND THEIR ONGOING RESPONSIBILITY FOR THE MAINTENANCE OF THE SYSTEMS.

    4. BUILDER TO CONFIRM WITH OWNER THE CHOSEN METHOD OF TIMBER PROTECTION.5. OWNER REMAINS RESPONSIBLE FOR ONGOING INSPECTION OF STRUCTURAL TIMBER ELEMENTS, AND THAT

    BARRIERS ARE NOT COMPROMISED.6. WHERE CONCRETE SLAB FORMS BARRIER, SLAB TO BE CONSTRUCTED AS PER AS2870. SLAB & FOOTINGS TO

    BE "MONOLITHIC". TERMIMESH FLANGE TO BE CLAMPED TO PIPES AND SET IN SLAB. 75MM MIN OF EXPOSED SLAB EDGE TO REMAIN ABOVE FINISHED PERIMETER LEVEL. EXPOSED EDGE NOT TO BE COVERED BY SOIL, RENDERED OR TILED, BUT MAY BE PAINTED. WHERE BRICKWORK CONCEALS EDGE OF SLAB, IN ADDITION TO ABOVE, PROVIDE TERMIMESH BARRIER BELOW D.P.C. FIXED TO SLAB EDGE.

    7. INSTALL ANT CAPPING TO ALL BRICK PIERS, TIMBER OR CONC STUMPS. KEEP TIMBER CLEAR OF GROUND WHEN ON STEEL ANCHORS. NON-TIMBER ELEMENTS (EG STEEL POSTS) NEED NO PROTECTION FROM TERMITES.

    8. ALL TIMBER IN DIRECT CONTACT WITH CONC TO BE SEPARATED BY G.I. FLASHING.

    FLOOR PLAN NOTES:

    1. SMOKE ALARMS TO BE INSTALLED IN ACCORDANCE WITH THE NCC PART 3.7.2 - SMOKE ALARMS. SMOKE ALARMS MUST COMPLY WITH AS3786.• ONLY USE PHOTOELECTRIC TYPE SMOKE

    ALARMS• ALL SMOKE ALARMS TO BE

    INTERCONNECTED• INSTALL LOCATIONS:

    1. ON EACH LEVEL OF LIVING SPACE2. OUTSIDE EACH BEDROOM AREA3. IN EVERY BEDROOM

    2. WALL FINISHES AND WINDOW TYPES ON 3D VIEWS ARE INDICATIVE ONLY AND ARE NOT PRESCRIPTIVE.

    3. BUILDER TO CONFIRM ALL DIMENSIONS PRIOR TO CONSTRUCTION. DIMENSIONS ARE TO FRAME ONLY AND DO NOT INCLUDE CLADDING/LININGS (UNO).

    4. S.S. BALUSTRADING TO COMPLY WITH CURRENT NCC VOLUME 2 SECTION 3.9.2.3 'WIRE BALUSTRADING CONSTRUCTION'

    5. DOORS TO W.C.'S TO HAVE LIFT OFF HINGES (ONLY IF THE DOORS SWING IN TOWARDS THE W.C).

    6. MASONRY CONSTRUCTION TO AS 3700.7. REFER ENGINEERS DRAWINGS & SPECIFICATIONS

    FOR ALL STRUCTURAL DETAILS, FRAMING, BRACING, TIE DOWN AND SLAB/FOOTING DETAILS.

    8. SEAL WET AREAS IN ACCORDANCE WITH AS3740 & NCC REQUIREMENTS.

    9. PROVIDE FLOOR WASTE TO ALL WET AREAS.

    3D VIEW NOTES:

    1. GROUND LINE OR SLOPE OF SITE IS NOT REPRESENTED ON 3D VIEWS.

    2. FURNITURE AND FIXTURES ARE INDICATIVE ONLY AND ARE NOT PRESCRIPTIVE.

    3. 3D VIEWS, PERSPECTIVES AND ILLUSTRATIONS ARE INTENDED TO BE A VISUAL AID ONLY, THEY ARE NOT PRESCRIPTIVE BUT INDICATIVE ONLY. THE IMAGES ARE NOT TO BE RELIED UPON IN ANY WAY FOR FINAL CONSTRUCTION FINISHES AND RESULTS.

    ELEVATION NOTES:

    1. WALL FINISHES AND WINDOW TYPES ARE INDICATIVE ONLY AND ARE NOT PRESCRIPTIVE. REFER TO BUILDERS SPECIFICATIONS FOR DETAILS.

    2. GROUND LINE SHOWN ON ELEVATIONS DOES NOT RELATE TO ACTUAL SLOPE OF SITE.

    3. FURNITURE AND FIXTURES ARE INDICATIVE ONLY AND ARE NOT PRESCRIPTIVE.

    4. ELEVATIONS ARE INTENDED TO BE A VISUAL AID ONLY, THEY ARE NOT PRESCRIPTIVE BUT INDICATIVE ONLY. THE IMAGES ARE NOT TO BE RELIED UPON IN ANY WAY FOR FINAL CONSTRUCTION FINISHES AND RESULTS.

    SECTION NOTES:

    1. TRUSS DESIGN IS INDICATIVE ONLY AND IS NOT PRESCRIPTIVE. FINAL DESIGN TO TRUSS MANUFACTURER SPECIFICATIONS.

    2. ALL PINE TO BE JD4 MIN.3. ALL HWD. TO BE F14 MIN.4. GROUND LINE SHOWN DOES NOT RELATE TO

    ACTUAL SLOPE OF SITE.5. FURNITURE AND FIXTURES ARE INDICATIVE ONLY

    AND ARE NOT PRESCRIPTIVE.6. SECTIONS ARE INTENDED TO BE A VISUAL AID

    ONLY, THEY ARE NOT PRESCRIPTIVE BUT INDICATIVE ONLY. THE IMAGES ARE NOT TO BE RELIED UPON IN ANY WAY FOR FINAL CONSTRUCTION FINISHES AND RESULTS.

    FOUNDATION NOTES:

    1. THESE PLANS ARE TO BE READ IN CONJUNCTION WITH CONTRACT DOCUMENTS AND ENGINEERS DRAWINGS AND SPECIFICATIONS. RESPONSIBLE PARTIES ARE TO BE NOTIFIED OF ANY DISCREPANCIES. SITE CLASSIFICATION IS TO BE CONFIRMED BY INSPECTION OF FOOTING EXCAVATIONS.

    2. PLUMBER RESPONSIBLE TO LOCATE AND CONFIRM SEWER HOUSE CONNECTION LOCATION ACCURATELY PRIOR TO COMMENCEMENT. PLUMBER IS TO VERIFY WITH SITE SUPERVISOR PRIOR TO SETTING OUT FIXTURE DRAINAGE POINTS. NO AMENDMENTS OR SPECIAL FIXTURES HAVE BEEN NOMINATED.

    3. WHERE SERVICES / PIPEWORK ARE LOCATED UNDER DRIVEWAYS AND SLABS CONTRACTORS ARE TO ENSURE ADEQUATE COMPACTION TO TRENCH BACKFILL ACHIEVED TO SUPPORT CONCRETE.

    4. REBATE GARAGE DOORS & SLIDING GLASS DOORS 20mm, AND SHOWER RECESSES 50mm IN LOCATIONS SHOWN.

    5. ACCORDING TO MANUF' SPEC. OR BUILDERS DIRECTIONS.

    6. MINIMUM COVER TO GROUND - 50mm.7. TOP COVER TO SLAB REINFORCEMENT - 30mm.8. GRADE FINISHED GROUND SURFACE TO DIVERT

    WATER AWAY FROM BUILDING.9. WATERPROOF MEMBRANE IS 0.2mm

    POLYETHYLENE. JOINTS ARE TO BE LAPPED 300mm AND TAPED.

    10. REINFORCEMENT TO BE SUPPORTED ON PLASTIC CHAIRS AT 1000mm CRS.

    11. ALL CONCRETE IS TO BE MECHANICALLY VIBRATED DURING PLACING.

    12. FILL MATERIAL AND SAND UNDER SLABS IS TO BE COMPACTED TO 95% OF MAX. DRY DENSITY.

    13. FLOORS TO ALL WET AREAS TO HAVE A FALL TO A FLOOR WASTE.

    ELECTRICAL NOTES:

    1. SMOKE ALARMS TO BE INSTALLED IN ACCORDANCE WITH THE NCC PART 3.7.2 - SMOKE ALARMS. SMOKE ALARMS MUST COMPLY WITH AS 3786.• ONLY USE PHOTOELECTRIC TYPE SMOKE

    ALARMS• ALL SMOKE ALARMS TO BE

    INTERCONNECTED• INSTALL LOCATIONS:

    1. ON EACH LEVEL OF LIVING SPACE2. OUTSIDE EACH BEDROOM AREA3. IN EVERY BEDROOM

    2. THIS PLAN IS INDICATIVE ONLY AND IS TO BE USED ONLY AS AN EXAMPLE. OWNERS TO NOMINATE FINAL POSITIONS OF ELECTRICAL APPLIANCES, LIGHTING AND ELECTRICAL FITTINGS.

    PROPOSED RESIDENCE FOR

    AREI DESIGNS

    CONSTRUCTION DRAWINGS

    ADDRESS

    LOT 116 AREI CRESCENT AUGUSTA

    EXAMP

    LE PLA

    N ONLY

  • 1500

    6000

    1500

    3820

    AREI CRESCENT

    27° 24' 00"

    34.092 m

    117° 24' 25"

    19.400 m

    207° 24' 00"

    34.092 m

    297° 24' 25"

    19.400 m

    LOT 116

    SP 250657

    LOT 117SP 250657

    LOT 115SP 250657

    LINE OF WALL

    6452

    6450

    KERB

    DRIVEWAY

    CLIENT: PROJECT:

    DRAWING NAME:SCALE @ A3

    PROPOSED RESIDENCE FOR

    PAGE NO:OF 09

    PLAN NUMBER:

    DRAWN:

    CHECKED:

    DATE:

    M: 0419 786 578M: 0403 508 705E: [email protected]

    USE SCALE & RULER AS A GUIDE ONLY

    1:200

    AREI DESIGNS AT

    BEN DYE

    BEN DYELOT 116 AREI CRESCENT

    AUGUSTA

    AREI DESIGNS

    W: areidesigns.com.auABN: 31614195818QBCC LIC: 15040397

    C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED

    AREI PLAN CODE:1 3 5 7 9

    0m 2m 4m 6m 8m 10m

    SITE PLAN

    02A001-17

    01/01/17

    SERIES 3 ASC1

    PROPERTY DESCRIPTION

    LOT: 116 SP250657SUBURB: KIRKWOODLOCALITY: GLEN EDENLOCAL AUTHORITY: GRCZONING: LD RESIDENTIAL AREA OF LOT - 661m²AREA OF RESIDENCE - 208.1m²SITE COVERAGE - 31.48%

    AREA OF DRIVEWAY - 60m²

    COUNCIL ONLINE MAPPING AERIAL VIEW

    PP

    DP

    LEGEND

    W

    H

    GM

    WATER CONNECTION

    TELSTRA PIT

    ELECTRICAL TURRET

    MAN HOLE

    SEWER LINE

    STREET LIGHT

    POWER POLE

    CONTOUR LINE

    EXISTING RETAINING

    NEW RETAINING

    ROOF LINE

    STORM WATER PIT

    STORM WATER LINE

    FENCE

    ELECTRICAL

    HYDRANT

    TELSTRA COMMUNICATIONS

    UNDERGROUND GAS MARKER

    WATER LINE

    100mm DOWN PIPE

    T

    REV. REVISION DESCRIPTION APPROV. DATE

    A CONSTRUCTION ISSUE 01/01/17

    EXAMP

    LE PLA

    N ONLY

  • PATIOCONCRETE

    DININGTILE

    KITCHENTILE

    LIVINGTILE

    ENTRYTILE

    PORCHCONCRETE

    GARAGECONCRETE

    STUDYTILE

    WIPTILE

    LDRYTILE

    W.CTILE

    BATHTILE

    BED 2CARPET

    BED 3CARPET

    MASTERCARPET

    WIRCARPET

    WIRCARPET

    ENSTILE

    LINEN

    LINEN

    CUP'D

    ROBEROBE

    18/21 S.WW17

    18/06 LU

    W12

    18/075 CNR F.GW11

    18/06 LUW13

    21/045 LU

    W14

    18/09 LU

    W8

    21/06 F.GW10

    21/06 F.GW9

    12/15 S.WW1

    21/15 SL.G.DW2

    09/06 S.WW3

    12/15 S.WW4

    18/12 S.WW5

    18/12 S.WW6

    18/06 D.HUW18

    12/18 LU

    W15

    06/18 S.WW16

    21/36 SL.G.D STACKER

    W7

    820

    D10

    210/75

    OPENING

    21/075

    OPENING

    820D4

    820D3

    720

    D6

    720D5

    820

    D2

    820

    D1

    21/48 PANEL LIFT

    D7

    920

    D8

    720

    D11

    820

    D9

    21/10OPENING

    15/078

    NICHE

    21/095

    OPENING

    BATH

    VANITY

    SHWR

    W/M

    TUB

    SHWRVANITY

    W.C.

    SINK

    FRIDGE

    W.C.

    D/W

    ASH

    U/B OVENH/PLATE

    2.400m CEILING HEIGHTCONCRETE CONSTRUCTION

    450 O/H FROM O/S BRICK 20° COLORBOND

    450 O/H FROM O/S BRICK 20° COLORBOND

    OHC

    OHC

    1140 4680 8830 4700

    3940

    1500

    1500

    6240

    450

    1590 1550 3410 12800

    480

    3250

    3430

    2420

    4050

    1400 5970

    2670

    4504230

    150 1903890

    150

    190

    3710

    1270

    930190 150

    1130

    1870

    150

    190

    1530

    19350

    19350

    13630

    13630

    220

    2990

    220

    220

    2990

    70

    2350

    220

    220

    3210

    70

    5410

    220

    220

    530

    70

    3060

    70

    950

    70

    4390

    220

    220

    530

    70

    3060

    70

    950

    70

    2160

    70

    2160

    220

    220

    5800

    220

    220

    1570

    70

    1570

    70

    4020

    220

    220

    3500

    220

    220

    3210

    7095070

    530

    70

    2400

    70

    1800

    70

    3500

    220

    220

    2190

    70

    1970

    70

    530

    70

    2400

    7078070

    950

    70

    3500

    220

    220

    3210

    70

    950

    70

    8440

    220

    220

    3210

    70

    950

    70

    8440

    220

    2201450

    701450

    220

    2201480

    701450

    701450

    701480

    701900

    70950

    701620

    70530

    705900

    220

    2208390

    220

    2204050

    2101460

    220

    2203240

    701300

    704050

    2101460

    220

    2203000

    703000

    701900

    70950

    701620

    70530

    705900

    220

    2201500

    901800

    709480

    705900

    220

    2201500

    902790

    701300

    704050

    901330

    701580

    220

    2201500

    902790

    701300

    704050

    901330

    701580

    705900

    220

    750

    2890

    750

    1000 3050

    950

    70

    780

    1300 900 1250 600

    4520

    3920

    1040

    960

    1270

    600 ENS

    ENS

    ENS

    ENS

    BED 3

    BED 3

    BED 3

    BED 3

    BED 2

    BATH

    BATH

    BATH

    BED 2

    BED 2

    ROBE

    ROBE

    ROBE

    ROBE

    ROBE

    ROBE

    MASTERMASTER

    MASTER

    MASTER

    MASTER

    MASTER

    MASTERENS WIR

    WIR

    WIR

    WIR

    WIR

    HALL

    HALL

    HALL

    HALL

    HALL

    HALL

    KIT/DIN

    HALL

    KITCHEN

    KITCHEN

    KITCHEN

    KITCHEN

    KITCHEN

    OPENING

    KITCHEN

    KITCHEN

    KITCHEN

    KITCHEN

    ENTRY

    ENTRY

    ENTRY

    WIP

    WIP

    WIP

    WIP

    STUDY

    STUDY

    STUDY

    LIV/DIN

    LIV/DIN

    LIV/DIN

    LIV/DIN

    OPENING

    NICHE

    KIT/DIN

    OPENING

    NICHE

    GARAGE

    GARAGE

    GARAGE

    GARAGE

    GARAGE

    CUP'D

    CUP'D

    LINEN

    LINEN

    LINEN

    LINEN

    LDRY

    LDRY

    LDRY

    W.C

    W.C

    HALL

    KITCHEN

    BATH

    190x190 F14 HWD POST,DURABILITY 1 OR 2

    220mm BRICK VENEER

    OPENING

    OPENING

    CLIENT: PROJECT:

    DRAWING NAME:SCALE @ A3

    PROPOSED RESIDENCE FOR

    PAGE NO:OF 09

    PLAN NUMBER:

    DRAWN:

    CHECKED:

    DATE:

    M: 0419 786 578M: 0403 508 705E: [email protected]

    USE SCALE & RULER AS A GUIDE ONLY

    1:100

    AREI DESIGNS AT

    BEN DYE

    BEN DYELOT 116 AREI CRESCENT

    AUGUSTA

    AREI DESIGNS

    W: areidesigns.com.auABN: 31614195818QBCC LIC: 15040397

    C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED

    AREI PLAN CODE:.5 .5 .5 .5 .5

    0m 1m 2m 3m 4m 5m

    FLOOR PLAN

    03A001-17

    01/01/17

    SERIES 3 ASC1

    A

    B

    C

    D

    WINDOW SCHEDULE

    MARK SIZE DESCRIPTION

    W1 1200 x 1500 ALUM. FRAMED SLIDING WINDOW

    W2 2100 x 1500 ALUM. FRAMED SLIDING GLASS DOOR

    W3 900 x 600 ALUM. FRAMED SLIDING WINDOW

    W4 1200 x 1500 ALUM. FRAMED SLIDING WINDOW

    W5 1800 x 1200 ALUM. FRAMED SLIDING WINDOW

    W6 1800 x 1200 ALUM. FRAMED SLIDING WINDOW

    W7 2100 x 3600 ALUM. FRAMED SLIDING GLASS DOOR

    W8 1800 x 900 ALUM. FRAMED LOUVERS

    W9 2100 x 300 ALUM. FRAMED FIXED GLASS

    W10 2100 x 300 ALUM. FRAMED FIXED GLASS

    W11 1800 x 750 x 750 ALUM. FRAMED CORNER FIXED GLASS

    W12 1800 x 600 ALUM. FRAMED LOUVERS

    W13 1800 x 600 ALUM. FRAMED LOUVERS

    W14 2100 x 450 ALUM. FRAMED LOUVERS

    W15 1200 x 1800 ALUM. FRAMED LOUVERS

    W16 600 x 1800 ALUM. FRAMED SLIDING WINDOW

    W17 1800 x 2100 ALUM. FRAMED SLIDING WINDOW

    W18 1800 x 600 ALUM. FRAMED DOUBLE HUNG

    DOOR SCHEDULE

    MARK SIZE DOOR TYPE

    D1 2100 x 820 HOLLOW CORE SWING

    D2 2100 x 820 HOLLOW CORE SWING

    D3 2100 x 820 HOLLOW CORE SWING

    D4 2100 x 820 HOLLOW CORE SWING

    D5 2100 x 720 HOLLOW CORE SWING

    D6 2100 x 720 HOLLOW CORE SWING

    D7 2100 x 4800 PANEL LIFT DOOR

    D8 2040 x920 SOLID CORE SWING

    D9 2100 x 820 HOLLOW CORE CAVITY SLIDER

    D10 2100 x 820 HOLLOW CORE SWING

    D11 2100 x 720 HOLLOW CORE CAVITY SLIDER

    FLOOR AREAS

    GARAGE 38.2 m²

    LIVING 148.3 m²

    PATIO 17.1 m²

    PORCH 4.5 m²

    TOTAL 208.1 m²

    C CASEMENT WINDOWSL.G.D SLIDING GLASS DOORS.W SLIDING WINDOWA AWNING WINDOWD.HU DOUBLE HUNG WINDOWB.D. BIFOLD DOORSLU LOUVERSSL SIDELIGHTM.V. MECHANICAL VENTSKL SKYLIGHTF.G. FIXED GLASS WINDOW

    REV. REVISION DESCRIPTION APPROV. DATE

    A CONSTRUCTION ISSUE 01/01/17

    LEGEND

    EXAMP

    LE PLA

    N ONLY

  • CLIENT: PROJECT:

    DRAWING NAME:SCALE @ A3

    PROPOSED RESIDENCE FOR

    PAGE NO:OF 09

    PLAN NUMBER:

    DRAWN:

    CHECKED:

    DATE:

    M: 0419 786 578M: 0403 508 705E: [email protected]

    USE SCALE & RULER AS A GUIDE ONLY

    1:150

    AREI DESIGNS AT

    BEN DYE

    BEN DYELOT 116 AREI CRESCENT

    AUGUSTA

    AREI DESIGNS

    W: areidesigns.com.auABN: 31614195818QBCC LIC: 15040397

    C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED

    AREI PLAN CODE: 0m 1.5m 3m 4.5m 6m 7.5m

    3D VIEWS

    04A001-17

    01/01/17

    SERIES 3 ASC1

    REV. REVISION DESCRIPTION APPROV. DATE

    A CONSTRUCTION ISSUE 01/01/17

    EXAMP

    LE PLA

    N ONLY

  • 2100 W

    INDOW HT

    2400 CEILING HT

    5227 OVERALL HT

    PITCH20.0°

    450

    COLORBOND ROOF

    EXTERNAL BRICK

    2100 W

    INDOW HT

    2400 CEILING HT

    5227 OVERALL HT

    PITCH20.0°

    450

    COLORBOND ROOF

    190x190 F14 HWD. POSTDURABILITY 1 OR 2

    EXTERNAL BRICK

    2100 W

    INDOW HT

    2400 CEILING HT

    5227 OVERALL HT

    COLORBOND ROOF

    190x190 F14 HWD. POSTDURABILITY 1 OR 2

    450

    PITCH20.0°

    EXTERNAL BRICK

    2100 W

    INDOW HT

    2400 CEILING HT

    5227 OVERALL HT

    450

    PITCH20.0°

    COLORBOND ROOF

    21/48 PANEL LIFT DOOR EXTERNAL BRICK190x190 F14 HWD. POSTDURABILITY 1 OR 2

    CLIENT: PROJECT:

    DRAWING NAME:SCALE @ A3

    PROPOSED RESIDENCE FOR

    PAGE NO:OF 09

    PLAN NUMBER:

    DRAWN:

    CHECKED:

    DATE:

    M: 0419 786 578M: 0403 508 705E: [email protected]

    USE SCALE & RULER AS A GUIDE ONLY

    1:100

    AREI DESIGNS AT

    BEN DYE

    BEN DYELOT 116 AREI CRESCENT

    AUGUSTA

    AREI DESIGNS

    W: areidesigns.com.auABN: 31614195818QBCC LIC: 15040397

    C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED

    AREI PLAN CODE:.5 .5 .5 .5 .5

    0m 1m 2m 3m 4m 5m

    ELEVATIONS

    05A001-17

    01/01/17

    SERIES 3 ASC1

    A

    B

    C

    D

    ELEVATION A

    ELEVATION B

    ELEVATION C

    ELEVATION D

    REV. REVISION DESCRIPTION APPROV. DATE

    A CONSTRUCTION ISSUE 01/01/17

    EXAMP

    LE PLA

    N ONLY

  • BATHKITCHENDINING

    CONCRETE SLAB/FOOTING TO ENGINEERS DESIGN

    PREFABRICATED ROOF TRUSSES TO MANUFACTURERS SPECIFICATIONS

    PITCH20.0°

    REFER TO TYPICAL SECTION

    2100 W

    INDOW HT

    2400 CEILING HT

    5227 OVERALL HT

    ROOF BATTENS @ 900 CRS MAX. INTERMITTENT SAFETY BATTENS AS REQUIRED

    FOIL WRAP & INSULATION TO MEET CURRENT NCC REQUIREMENTS

    SELECT EXTERNAL BRICK WITH WALL TIES TO AS 3700

    WEEPHOLES @ 1.2m MAX.INSTALL DAMP PROOF COURSE AS PER NCC REQUIREMENTS

    TERMITE MONITORING SYSTEM TO AS 3660. METHOD TO BUILDERS & OWNERS DISCRETION

    90/70x35 PINE EXTERNAL TIMBER FRAME MGP1290/70x35 PINE INTERNAL TIMBER FRAME MGP10

    SELECTED INSULATION IN ACCORDANCE WITH ENERGY EFFICIENCY AND CURRENT NCC REQUIREMENTS

    CONCRETE FLOOR

    10mm PLASTERBOARD INTERNAL SHEETINGWET AREA PLASTERBOARD IN COMMON WET AREAS

    RIBBON PLATE

    35x45 PINE CEILING BATTENSOR METAL FURRING CHANNELS @ 450 CRS MAX

    COLORBOND FASCIA AND GUTTER

    F.C. SHEET SOFFITS AND INFILLS

    COLORBOND ROOF OVER FOIL SARKING

    CONCRETE SLAB/FOOTING TO ENGINEERS DESIGN

    PREFABRICATED ROOF TRUSSES TO MANUFACTURERS SPECIFICATIONS

    LINTEL AS PER ENGINEERS DESIGN

    NOTES:• BRACING, CONNECTIONS AND TIE-DOWN TO ENGINEERS DESIGN

    • ROOF PITCH AS NOTED ON PLANS AND ELEVATIONS

    • OVERHANG AS NOTED ON PLANS AND ELEVATIONS

    • PIPE PENETRATIONS TO NCC REQUIREMENTS

    CEILING HEIGHT AS PER PLA

    NS AND ELEVATIONS

    BRICK SILL WITH FLASHING AND WEEP HOLES

    WINDOW AND FLASHINGS INSTALLED TO MANUFACTURERS REQUIREMENTS

    CLIENT: PROJECT:

    DRAWING NAME:SCALE @ A3

    PROPOSED RESIDENCE FOR

    PAGE NO:OF 09

    PLAN NUMBER:

    DRAWN:

    CHECKED:

    DATE:

    M: 0419 786 578M: 0403 508 705E: [email protected]

    USE SCALE & RULER AS A GUIDE ONLY

    1:100

    AREI DESIGNS AT

    BEN DYE

    BEN DYELOT 116 AREI CRESCENT

    AUGUSTA

    AREI DESIGNS

    W: areidesigns.com.auABN: 31614195818QBCC LIC: 15040397

    C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED

    AREI PLAN CODE:.5 .5 .5 .5 .5

    0m 1m 2m 3m 4m 5m

    CROSS SECTION

    06A001-17

    01/01/17

    SERIES 3 ASC1

    1 : 20TYPICAL SECTION

    REV. REVISION DESCRIPTION APPROV. DATE

    A CONSTRUCTION ISSUE 01/01/17

    EXAMP

    LE PLA

    N ONLY

  • 75mm STEP

    1140 4680 8830 4700

    3940

    1500

    1500

    6240

    450

    1370 1550 3410 12800

    3430

    2420

    4050

    1400 5970

    2670

    4504230

    150 1903890

    150

    190

    3710

    1270

    930190 150

    1130

    1870

    150

    190

    1530

    19130

    19350

    13630

    13630

    380

    540

    1470

    1735

    2930

    380

    465

    970 6800

    6450

    720

    18652760

    8140

    8955

    10470

    10900

    11155

    75mm STEP

    RE-ENTRANT BARS

    APPROX. FIXTURE POSITION

    450

    3280

    DIMENSIONS TO ALL WASTEPIPES ARE APPROX ONLY.ALTERNATE FIXTURES MAYCAUSE PIPE VARIATION.

    SLABMESH TO ENGINEERS SPECIFICATIONS

    1900 9500

    220

    3210

    220

    2990

    220

    2201500

    BATH

    BATH

    ENS

    ENS

    CLIENT: PROJECT:

    DRAWING NAME:SCALE @ A3

    PROPOSED RESIDENCE FOR

    PAGE NO:OF 09

    PLAN NUMBER:

    DRAWN:

    CHECKED:

    DATE:

    M: 0419 786 578M: 0403 508 705E: [email protected]

    USE SCALE & RULER AS A GUIDE ONLY

    1:100

    AREI DESIGNS AT

    BEN DYE

    BEN DYELOT 116 AREI CRESCENT

    AUGUSTA

    AREI DESIGNS

    W: areidesigns.com.auABN: 31614195818QBCC LIC: 15040397

    C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED

    AREI PLAN CODE:.5 .5 .5 .5 .5

    0m 1m 2m 3m 4m 5m

    FOUNDATION PLAN

    07A001-17

    01/01/17

    SERIES 3 ASC1

    REV. REVISION DESCRIPTION APPROV. DATE

    A CONSTRUCTION ISSUE 01/01/17

    EXAMP

    LE PLA

    N ONLY

  • ELECTRICAL & FIXTURES LEGEND

    DOWN LIGHT RECESSED

    FLOOD LIGHT EXTERNAL

    FLUORO SINGLE 900mm

    TELEVISION POINT

    PHONE/DATA POINT

    GPO DOUBLE

    GPO SINGLE

    GPO SINGLE WATERPROOF

    METER BOX

    CEILING FAN

    SMOKE DETECTOR

    SYMBOL DESCRIPTION

    DISTRIBUTION BOX

    FLUORO DOUBLE 900mm

    GPO DOUBLE WATERPROOF

    OYSTER FLUORO LIGHT

    TRACK LIGHT

    HEAT LAMP LIGHT

    HEAT EXHAUST LIGHT (3in1)

    UP/DOWN LIGHT

    EXHAUST LIGHT

    LED STRIP LIGHTING

    EXTERIOR SENSOR LIGHT

    ANTENNA

    FLOOD LIGHT EXTERNAL (2)

    EXHAUST CEILING FAN

    EXHAUST WALL FAN

    AIR CON HEAD (SPLIT)

    AIR CON UNIT (SPLIT)

    HOT WATER SYSTEM

    DINING

    ?

    ENTRY

    LIVING

    KITCHEN

    MASTER

    WIR

    WIR

    ENS

    BED 3 BED 2

    BATH

    W.C

    LDRY

    GARAGE

    STUDY

    WIP

    PATIO

    PORCH

    CLOTHES LINE

    LIGHT SWITCHESWALL MOUNTED LIGHTSPOWER OUTLETS (STANDARD)

    POWER OUTLETS OTHER

    M/WAVE OVEN ROWERM/WAVE UNDER BENCHKITCHEN BENCHREFRIGERATORRANGEHOODD/WASHVANITY BASINSLAUNDRY BENCHW/MACHINE

    1150mm AFL2000mm AFL300mm AFL

    1800mm AFL300mm AFL1000mm AFL1500mm AFL1800mm AFL300mm AFL1000mm AFL1000mm AFL1500mm AFL

    ELECTRICAL LINE

    POWER POINT HEIGHTS AFL

    2WAY 2WAY

    2WAY

    2WAY

    HOSE COCK

    GAS BOTTLES

    FLOOR WASTE

    PENDANT

    CLIENT: PROJECT:

    DRAWING NAME:SCALE @ A3

    PROPOSED RESIDENCE FOR

    PAGE NO:OF 09

    PLAN NUMBER:

    DRAWN:

    CHECKED:

    DATE:

    M: 0419 786 578M: 0403 508 705E: [email protected]

    USE SCALE & RULER AS A GUIDE ONLY

    1:100

    AREI DESIGNS AT

    BEN DYE

    BEN DYELOT 116 AREI CRESCENT

    AUGUSTA

    AREI DESIGNS

    W: areidesigns.com.auABN: 31614195818QBCC LIC: 15040397

    C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED

    AREI PLAN CODE:.5 .5 .5 .5 .5

    0m 1m 2m 3m 4m 5m

    ELECTRICAL & FIXTURES PLAN

    08A001-17

    01/01/17

    SERIES 3 ASC1

    REV. REVISION DESCRIPTION APPROV. DATE

    A CONSTRUCTION ISSUE 01/01/17

    EXAMP

    LE PLA

    N ONLY

  • TOTAL ROOF AREA = 252.2m²

    450mm ROOF OVERHANG TYP

    20° FALL

    20° FALL

    20° FALL

    20° FALL

    20° FALL

    20° FALL

    20° FALL

    20° FALL

    20° FALL

    DP

    DP

    DP DP

    DP

    DP DP DP

    DP

    450mm ROOF OVERHANG TYP

    COLORBOND CUSTOM ORB ROOF SHEETINGCOLORBOND FASCIA & GUTTER

    CONNECT TO LPOD

    CONNECT TO LPOD

    KE

    RB

    KE

    RB

    CLIENT: PROJECT:

    DRAWING NAME:SCALE @ A3

    PROPOSED RESIDENCE FOR

    PAGE NO:OF 09

    PLAN NUMBER:

    DRAWN:

    CHECKED:

    DATE:

    M: 0419 786 578M: 0403 508 705E: [email protected]

    USE SCALE & RULER AS A GUIDE ONLY

    1:100

    AREI DESIGNS AT

    BEN DYE

    BEN DYELOT 116 AREI CRESCENT

    AUGUSTA

    AREI DESIGNS

    W: areidesigns.com.auABN: 31614195818QBCC LIC: 15040397

    C COPYRIGHT AREI DESIGNS ALL RIGHTS RESERVED

    AREI PLAN CODE:.5 .5 .5 .5 .5

    0m 1m 2m 3m 4m 5m

    ROOF DRAINAGE

    09A001-17

    01/01/17

    SERIES 3 ASC1

    REV. REVISION DESCRIPTION APPROV. DATE

    A CONSTRUCTION ISSUE 01/01/17

    EXAMP

    LE PLA

    N ONLY

    Sheets01 - COVER02 - SITE PLAN03 - FLOOR PLAN04 - 3D VIEWS05 - ELEVATIONS06 - CROSS SECTION07 - FOUNDATION PLAN08 - ELECTRICAL & FIXTURES PLAN09 - ROOF DRAINAGE