CRIMINAL JUSTICE CENTER LOBBY AND LOCKER ROOM RENOVATION (COVID-19 CARES ACT) 2739 E. LAS VEGAS ST, COLORADO SPRINGS, CO 80906 100% CONSTRUCTION DOCUMENTS 07/15/2020 INDEX OF DRAWINGS VICINITY MAP SITE F OU NT A I N C R E E K SAND CREEK SAND CREEK I NTERSTA T E - 25 CANA M HWY E. L AS VEG AS ST E. L AS VEG AS ST EL POMAR YOUTH SPORTS PARK SPRING CREEK YOUTH SERVICES CENTER J AN IT EL L R D DELTA DR © DLR Group REVISIONS 7/15/2020 1:48:48 PM BIM 360://37-20111-01 Criminal Justice Center/37-20111-01_CriminalJusticeCenter_AR_2020.rvt 37 - 20111 - 01 07/15/2020 EL PASO COUNTY - CRIMINAL JUSTICE CENTER 100% CONSTRUCTION DOCUMENTS COVER SHEET G0.0 2739 E. LAS VEGAS ST, COLORADO SPRINGS, CO 80906 LOBBY AND LOCKER ROOM RENOVATION .ARCHITECTURAL. ADA1.1 DEMOLITION FLOOR PLAN ADA3.1 DEMOLITION REFLECTED CEILING PLAN A0.0 WALL TYPES A1.1 FLOOR PLAN A2.1 LARGE SCALE PLANS A3.1 REFLECTED CEILING PLAN A9.1 DOOR AND FRAME SCHEDULE A10.1 GENERAL BUILDING DETAILS A11.1 INTERIOR ELEVATIONS A11.2 INTERIOR ELEVATIONS A13.0 INTERIOR SCHEDULES A13.1 INTERIOR FINISH PLAN .GENERAL. G0.0 COVER SHEET G0.1 SYMBOLS AND ABBREVIATIONS CP1.1 PARTIAL CODE PLAN .MECHANICAL. M0.0 MECHANICAL LEGEND M0.1 MECHANICAL SPECIFICATIONS M1.1 MECHANICAL FLOOR PLAN .PLUMBING. P0.0 PLUMBING LEGEND P0.1 PLUMBING SPECIFICATIONS P1.1 PLUMBING FLOOR PLAN P6.1 PLUMBING SCHEDULES .ELECTRICAL. E0.1 ELECTRICAL LEGEND E1.2 ELECTRICAL SPECIFICATIONS ED1.1 ELECTRICAL DEMOLITION PLAN ED1.2 LIGHTING DEMOLOTION PLAN E1.1 ELECTRICAL PLAN E2.1 LIGHTING PLAN E6.1 ELECTRICAL ONE-LINE DIAGRAM E6.2 ELECTRICAL SCHEDULES NORTH E0. E0. P0.1 .2 M0.1 .2

Upload: others

Post on 11-May-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

CRIMINAL JUSTICE CENTERLOBBY AND LOCKER ROOM RENOVATION (COVID-19 CARES ACT)

2739 E. LAS VEGAS ST,

COLORADO SPRINGS, CO 80906

100% CONSTRUCTION DOCUMENTS

07/15/2020

INDEX OF DRAWINGSVICINITY MAP

SITE

FO

UN

TA

IN C

RE

EK

SAND CREEK

SAND CREEK

INTE

RSTA

TE - 25CANAM HW

Y

E. LA

S V

EG

AS

ST

E. LA

S V

EG

AS

ST

EL POMAR YOUTH SPORTS PARK

SPRING CREEK YOUTH SERVICES CENTER

JAN

ITE

LL R

D

DELTA DR

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:4

8 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

COVER SHEET

G0.0

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N.ARCHITECTURAL.

ADA1.1 DEMOLITION FLOOR PLAN

ADA3.1 DEMOLITION REFLECTED CEILING PLAN

A0.0 WALL TYPES

A1.1 FLOOR PLAN

A2.1 LARGE SCALE PLANS

A3.1 REFLECTED CEILING PLAN

A9.1 DOOR AND FRAME SCHEDULE

A10.1 GENERAL BUILDING DETAILS

A11.1 INTERIOR ELEVATIONS

A11.2 INTERIOR ELEVATIONS

A13.0 INTERIOR SCHEDULES

A13.1 INTERIOR FINISH PLAN

.GENERAL.

G0.0 COVER SHEET

G0.1 SYMBOLS AND ABBREVIATIONS

CP1.1 PARTIAL CODE PLAN

.MECHANICAL.

M0.0 MECHANICAL LEGEND

M0.1 MECHANICAL SPECIFICATIONS

M1.1 MECHANICAL FLOOR PLAN

.PLUMBING.

P0.0 PLUMBING LEGEND

P0.1 PLUMBING SPECIFICATIONS

P1.1 PLUMBING FLOOR PLAN

P6.1 PLUMBING SCHEDULES

.ELECTRICAL.

E0.1 ELECTRICAL LEGEND

E1.2 ELECTRICAL SPECIFICATIONS

ED1.1 ELECTRICAL DEMOLITION PLAN

ED1.2 LIGHTING DEMOLOTION PLAN

E1.1 ELECTRICAL PLAN

E2.1 LIGHTING PLAN

E6.1 ELECTRICAL ONE-LINE DIAGRAM

E6.2 ELECTRICAL SCHEDULES

NORTH

E0.E0.

P0.1

.2

M0.1

.2

Page 2: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

GENERAL SYMBOLS

???

?

?

???

SIM

???

?

?

???

?

???

??E

ast

XX/ A11.X

1

?

ROOM NAME

???

Program Area4.100?

1t

?

DESCRIPTION

DETAIL NUMBER

SHEET NUMBER

CROSS REFERENCE

WALL SECTION

SIMILAR OR TYPICALREFERENCE

DETAIL REFERENCE

BUILDING SECTION

BUILDING ELEVATIONINTERIOR ELEVATION

CASEWORK ELEVATION

KEYNOTE

COLUMN GRID LINE

ROOM NUMBER/NAME

DOOR NUMBER /INTERIOR WINDOW

EXTERIOR WINDOW NUMBER

WALL TYPE

REVISION NUMBER

EARTH

GRAVEL

SAND

CONCRETE

PRECAST CONCRETE

STEEL

GYM FLOOR

WOOD (CONTINUOUS BLOCKING)

WOOD (NON-CONTINUOUS BLOCKING)WOOD (TRIM/FINISH)

GLASS

STONE

SHINGLES

CONCRETE MASONRY UNIT

BRICK VENEER

STEEL (LARGE SCALE)

PLYWOOD (LARGE SCALE)

GYPSUM WALL BOARD

BATT INSULATION

RIGID INSULATION

SPRAY FOAM INSULATION

FIRE SAFING INSULATION

PROTECTION BOARD

CARPET (LARGE SCALE)

ACOUSTIC TILE (LARGE SCALE)

TILE (LARGE SCALE)

? ?

PROPERTY LINE

LOT LINE

EASMENT LINE

BUILDING LINE, EXISTING

BUILDING LINE, NEW W/DOOROPENING AND STRUCTURAL STOOP

PRIMARY CONTOUR, EXISTING

PRIMARY CONTOUR, NEW

SECONDARY CONTOUR, EXISTING

SECONDARY CONTOUR, NEW

SLOPE, PAVEMENT

DRAINAGE DITCH OR SWALE

STREET CENTERLINE

CURB, THICKENED EDGE

CURB, EXISTING

CURB, NEW

PAVING CONTRACTION JOINT

PAVING KEYED CONSTRUCTION JOINT

PAVING TIED CONSTRUCTION JOINT

PAVING EXPANSION JOINT

FENCE, SECURITY

FENCE, BARBED WIRE

FENCE, CHAIN LINK

FENCE, WOOD

SEED LIMIT

SOD LIMIT

STORM DRAIN

SUBDRAIN

SUBDRAIN, PERFORATED

SANITARY SEWER

FORCE MAIN

WATER

FIRE

GAS

HIGH PRESSURE STEAM

MEDIUM PRESSURE STEAM

LOW PRESSURE STEAM

UNDERGROUND ELEC/TELEPHONE

OVERHEAD POWER

LAWN SPRINKLER HOT LINE

LAWN SPRINKLER LATERAL

100

100

99

99

1% SLOPEDOWN

KCJ

KCT

EJ

xx xx xx xx

x x x x

SD

S

FM

W

F

G

HPS

MPS

LPS

UGE/UGT

OHP

HOT

LAT

AREA INLET

CURB INLET

MANHOLE

OBSERVATION RISER

HEAD WALL

FLARED END

CLEAN OUT

CAP

THRUST BLOCK

VALVE

POST INDICATOR VALVE

REDUCER

MAGNESIUM ANODE

DIELECTRIC COUPLING

CATHODIC TEST STATION

FIRE HYDRANT

POWER POLE

LIGHT POLE

TELEPHONE MANHOLE

TELEPHONE BOX

SPRINKLER HEAD, 360°

SPRINKLER HEAD, 270°

SPRINKLER HEAD, 180°

SPRINKLER HEAD, 90°

QUICK COUPLING

TREE, EXISTING DECIDUOUS

TREE, EXISTING CONIFER

SHADE TREE

ORNAMENTAL TREE

DECIDUOUS TREE

SHRUB

CLIPPED SHRUB

X'

X"

QC

FH

A

PIV

CO

OR

SITE SYMBOLS

GENERAL NOTES

A. GENERAL NOTES APPLY TO ALL SHEETS.B. DIMENSIONS ARE ACTUAL AND ARE TO FACE OF STUDS, FACE

OF CONCRETE WALLS, FACE OF CMU WALLS, FACE OF FRAMES, OR CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE.

C. SEE SHEET A0.0 FOR WALL TYPES. D. ALL INTERIOR STUD WALLS SHALL EXTEND TO UNDERSIDE OF

FLOOR OR ROOF DECK ABOVE UNLESS NOTED OTHERWISE. SEE REFLECTED CEILING PLAN NOTES.

E. PROVISIONS SHALL BE MADE AT ALL FULL HEIGHT NON-BEARING WALLS FOR 1-INCH VERTICAL MOVEMENT OF THE BUILDING STRUCTURE WITHOUT TRANSFER OF COMPRESSIVE LOADS TO WALL. FILL IRREGULARITIES BETWEEN TOP OF WALL AND DECK ABOVE WITH FIRE SAFING INSULATION OR FIRE STOPPING MATERIALS AS REQUIRED TO MEET FIRE RATING OF RESPECTIVE WALLS. SEE DETAILS 53/A0.0

F. ALL PENETRATIONS THROUGH WALLS SHALL BE SEALED WITH THRU-WALL FIRE STOPPING MATERIAL AS REQUIRED TO ACHIEVE THE RESPECTIVE FIRE-RESISTIVE RATING AND SMOKE STOPPAGE. SEE SPECIFICATION SECTION 078413.

G. FURNISH AND INSTALL FIRE-TREATED WOOD BLOCKING OR METAL BACKING PLATE IN METAL STUD PARTITIONS FOR THE PROPER ANCHORAGE OF ALL WALL ATTACHED ITEMS; I.E. TOILET ACCESSORIES, CASEWORK, MILLWORK, WALL-MOUNTED FIXTURES, MARKER BOARDS, TACK BOARDS, DOOR STOPS, AUDIO VISUAL BRACKETS, ETC.

H. INCLUDE ALL OWNER FURNISHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTOR INSTALLED ITEMS IN THE CONSTRUCTION SCHEDULE, AND SHALL COORDINATE WITH THE OWNER TO ACCOMMODATE THESE ITEMS.

I. COORDINATE ALL MECHANICAL CHASE SIZES WITH THE MECHANICAL CONTRACTOR.

J. EXTEND FURRING CHANNELS AND GYPSUM BOARD UP 4 INCHES ABOVE FINISHED CEILING ON CMU WALLS.

NOTE: LIGHTING LAYOUT TO BE REARRANGED PER NEW FLOOR PLAN, REBALANCE HVAC SYSTEM TO ACCOMODATE THE NEW FLOOR PLAN LAYOUT.

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:5

0 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

SYMBOLS ANDABBREVIATIONS

G0.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

ABBREVIATIONSVERT VERTICAL

VEST VESTIBULE

VF VINYL FLOOR

VOC VOLITILE ORGANIC COMPOUND

VOL VOLUME

VP VENEER PLASTER

VT VINYL TILE

VWC VINYL WALL COVERING

W WEST

W WIDE

W/ WITH

W/O WITHOUT

WB WALL BASE

WC WATER CLOSET

WC WALL COVERING

WCL WATER CLOSET/LAVATORY COMBINATION

WD WOOD

WDF WOOD FLOORING

WDW WINDOW

WG POLISHED WIRE GLASS

WI WROUGHT IRON

WOM WALK OFF MAT

WR WASTE RECEPTACLE

WRB WEATHER RESISTANT BARRIER

WW WARM WHITE

WWF WELDED WIRE FABRIC

YD YARD

NWC NORMAL WEIGHT CONCRETE

O to O OUT TO OUT

OA OVERALL

OC ON CENTER

OFCI OWNER FURNISHED CONTRACTOR INSTALLED

OFF OFFICE

OFOI OWNER FURNISHED OWNER INSTALLED

OPG(S) OPENING(S)

OPP OPPOSITE

OSHA OPERATIONAL SAFETY AND HEALTH ADMINISTRATION

OTB OPEN TO BELOW

OVFL OVERFLOW

OVHD OVERHEAD

P PAINT

PAN B PANIC BOLT

PAR PARALLEL

PB PARTICLE BOARD

PC PRECAST CONCRETE

PCD PAPER CUP DISPENSER

PCT PORCELAIN CERAMIC TILE

PD PANIC DEVICE

PENT PENTHOUSE

PERF PERFORATED

PERP PERPENDICULAR

PG PATTERN GLASS

PIC PORTABLE INSTRUMENT CONNECTION

PIG PATTERN INSULATING GLASS

PL PLATE

PL PROPERTY LINE

PL PLASTIC LAMINATE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PR PAIR

PREFAB PREFABRICATED

PROJ PROJECT(OR) (ION)

PS PROJECTION SCREEN

PT POINT

PTD PAPER TOWEL DISPENSER

PTD/R COMBINATION TOWEL DISPENSER/RECEPTACLE

PTN PARTITION

PVC POLYVINYL CHLORIDE

PWL SOUND POWER LEVEL

QT QUARRY TILE

QTR RND QUARTER ROUND

QTY QUANTITY

RAD RADIUS

RB RUBBER BASE

RC REMOTE CONTROL

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFERENCE

REFL REFLECTED

REM REMOVABLE

REQ(D) REQUIRE(D)

RESIL RESILIENT

REV REVISION(S)

RF RESILIENT FLOORING

RF RUBBER FLOOR

RFM RECESSED FLOOR MAT

RH ROBE HOOK

RI&C ROUGH IN AND CONNECT

RM ROOM

RND ROUND

S SOUTH

S SINK

SAT SPRAYED ACOUSTIC TREATMENT

SAW SOUND ABSORBING WALL UNITS

SB SPLASH BLOCK

SC SOLID CORE

SC SHOWER CURTAIN

SCD SEAT COVER DISPENSER

SCH SHOWER CURTAIN HOOK

SCHED SCHEDULE

SCR SHOWER CURTAIN ROD

SCT STRUCTURAL CLAY TILE

SD SOAP DISPENSER

SECT SECTION

SECY SECRETARY

SG SPANDREL GLASS

SGL SINGLE

SH SHOWER

SHM SECURITY HOLLOW METAL

SHT SHEET

SIM SIMILAR

SLNT SEALANT

SM SHEET METAL

SND SANITARY NAPKIN DISPOSAL

SNV SANITARY NAPKIN VENDOR

SPEC SPECIFICATION(S)

SPL SOUND PRESSURE LEVEL

SPL SPECIAL

SQ SQUARE

SS STAINLESS STEEL

SS SOLID SURFACE

SSA STORM SHELTER AREA

SSS STAINLESS STEEL SHELF

ST STONE

ST STAIR

STAG'D STAGGERED

STC SOUND TRANSMISSION CLASS

STD STANDARD

STGR STRINGER

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUBFL SUBFLOOR

SURF SURFACE

SUSP SUSPENDED

SV SHEET VINYL

SYM SYMETRICAL

T TREAD

T&G TONGUE AND GROOVE

T.O. TOP OF

TAN TANGENT

TB TOWEL BAR

TBD TACK BOARD

TCP TOILET COMPARTMENT PARTITION

TEMP TEMPORARY

TERR TERRAZZO

TG TINTED FLOAT GLASS

TH THRESHOLD

TI TENANT IMPROVEMENT

TIG TINTED INSULATING GLASS

TMR TILT MIRROR UNIT

TOP TOP OF PAVING

TRANS TRANSVERSE

TT TERRAZZO TILE

TTD TOILET TISSUE DISPENSER

TTG TINTED TEMPERED FLOAT GLASS

TTIG TINTED TEMPERED INSULATING GLASS

TW TACK WALL

TYP TYPICAL

UL UNDERWRITERS LABORATORIES

UNEX UNEXCAVATED

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UR URINAL

US UTILITY SHELF

UTIL UTILITY

VB VAPOR BARRIER

VB VINYL BASE

VCB VENTED COVE BASE

EXP EXPANSION

EXP EXPOSED

EXT EXTERIOR

F FABRIC

F.O. FACE OF

F.V. FIELD VERIFY

FAB FABRICATE(D)

FB FACE BRICK

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FIG FIGURE

FIN FINISHED

FIX FIXTURE

FL FLOOR

FLASH FLASHING

FLEX FLEXIBLE

FLG FLOORING

FLM FULL LENGTH MIRROR

FLUOR FLUORESCENT

FO FINISH OPENING

FOC FACE OF CONCRETE

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF STUD

FOW FACE OF WALL

FP FIREPROOFING

FR FIRE RESISTANT

FRP FIBERGLASS REINFORCED PANEL

FRT FIRE RESISTANCE TREATED

FS FLOOR SINK

FSS FOLDING SHOWER SEAT

FT FEET

FTG FOOTING

FUT FUTURE

FVC FIRE VALVE CABINET

FWC FABRIC WALL COVERING

G GROUT

GA GAUGE

GAL GALLON

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GD GARBAGE DISPOSAL

GEN GENERAL

GFA GROSS FLOOR AREA

GL GLUE LAMINATED

GL GLASS

GMP GUARANTTED MAXIMUM PRICE

GOVT GOVERNMENT

GR GUARD RAIL

GR GRADE

GRS GALVANIZED RIGID STEEL

GWB GYPSUM WALL BOARD

GYP GYPSUM

H HEIGHT

HC HOLLOW CORE

HD HAND DRYER

HDBD HARDBOARD

HDR HEADER

HDWD HARDWOOD

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HOUR

HR HANDRAIL

HS HARDWARE SET

HSS HOLLOW STRUCTURAL SHAPE

HVAC HEATING VENTILATING AND AIR CONDITIONING

i.e. THAT IS

IAW IN ACCORDANCE WITH

IBC INTERNATIONAL BUILDING CODE

ID INSIDE DIAMETER

IF INSIDE FACE

IJ ISOLATION JOINT

IJS IN JOIST SPACE

IN INCH

INC INCLUDE(ING)

INSUL INSULATION

INT INTERIOR

JAN JANITOR

JCT JUNCTION

JFB JOINT FILLER BOARD

JST JOIST

JT JOINT

KCJ KEYED CONSTRUCTION JOINT

KD KNOCKDOWN

KH KITCHEN HOOD

KIT KITCHEN

L ANGLE

LAB LABORATORY

LAM LAMINATED

LAV LAVATORY

LB(S) POUND(S)

LBR LUMBER

LDG LOADING

LF LINEAR FOOT

LG LENGTH (LONG)

LG LAMINATED GLASS

LIN LINEAR

LINO LINOLEUM

LKR LOCKER

LOC LOCATION

LONG LONGITUDINAL

LSC LIFE SAFETY CODE

LTG LIGHTING

LV LOUVER

LVT LUXURY VINYL TILE

LWC LIGHT WEIGHT CONCRETE

M THOUSAND

MAG MAGNETIC

MAINT MAINTENANCE

MAN MANUAL

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MB MOP BASIN

MBD MARKER BOARD

MBH MOP/BROOM HOLDER

MC MEDICINE CABINET

MECH MECHANICAL

MEMB MEMBRANE

MEZZ MEZZANINE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MR/S MIRROR WITH SHELF

MTD MOUNTED

MTG MOUNTING

MUL MULLION

N NORTH

NA NOT APPLICABLE

NC NOISE CRITERIA

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NOM NOMINAL

NTS NOT TO SCALE

# NUMBER

& AND

@ AT

AB ANCHOR BOLT

AB AIR BARRIER

ABS ASBESTOS

ACC ADA ACCESSIBLE

ACR ACRYLIC

AD ACCESS DOOR

ADA AMERICANS WITH DISABILITY ACT

ADDN ADDITION OR ADDITIONAL

ADJ ADJUSTABLE

ADJT ADJACENT

ADMIN ADMINISTRATION

AEC AUTOMATED EXTERNAL DEFIBRILLATIORS

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

AL ALUMINUM

ALT ALTERNATE

ALUM ALUMINUM

ANCH ANCHOR

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

AP ACCESS PANEL

APC ACOUSTIC PANEL CEILING

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASPH ASPHALT

AUTO AUTOMATIC

AVG AVERAGE

AWP ACOUSTIC WALL PANEL

B.O. BOTTOM OF

BCS BABY CHANGING STATION

BD BOARD

BLDG BUILDING

BLK BLOCK

BLKG BLOCKING

BLKHD BULKHEAD

BM(S) BEAM(S)

BOT BOTTOM

BRDG BRIDGING

BRG BEARING

BRKT BRACKET

BSMT BASEMENT

BT BATHTUB

BTWN BETWEEN

C CHANNEL

CAB CABINET

CANT CANTILEVER

CAP CAPACITY

CBD CHALKBOARD

CER CERAMIC

CF CUBIC FEET

CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED

CFSF COLD-FORMED STEEL FRAMING

CG CLEAR FLOAT GLASS

CI CAST IRON

CIG CLEAR INSULATING GLASS

CIP CAST IN PLACE

CJ CONTROL JOINT

CJA CONTROL JOINT ABOVE

CL CENTER LINE

CLG CEILING

CLOS CLOSET

CLR CLEAR

CMU CONCRETE MASONRY UNIT

COL COLUMN

COM COMMON

COMB COMBINATION

COMM COMMUNICATIONS

COMPR COMPRESSIBLE

CONC CONCRETE

CONF CONFERENCE

CONFIG CONFIGURATION

CONN(S) CONNECTION(S)

CONST CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACT(OR)

CORR CORRIDOR

CP COVER PLATE

CPT CARPET

CR CHAIR RAIL

CS COUNTERSINK

CSTJ CONSTRUCTION JOINT

CSWK CASEWORK

CT CERAMIC TILE

CTG CLEAR TEMPERED FLOAT GLASS

CTIG CLEAR TEMPERED INSULATING GLASS

CTR CENTER

CU COPPER

CU CUBIC

CU COMBINATION UNIT

CV CONDOM VENDOR

CY CUBIC YARD

CYL CYLINDER

D DEPTH

DB DECIBEL

DBL DOUBLE

DC DUST COLLECTOR

DEG DEGREE

DEMO DEMOLISH OR DEMOLITION

DEPR DEPRESS(ION)(ED)

DEPT DEPARTMENT

DET DETAIL

DET DETENTION

DF DRINKING FOUNTAIN

DG DOOR GRILLE

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DIV SPECIFICATION DIVISION

DN DOWN

DPFG DAMPROFFING

DR DOOR

DSN DOWNSPOUT NOZZLE

DW DISHWASHER

DWG(S) DRAWING(S)

DWL(S) DOWEL(S)

DWR DRAWER

E EAST

EA EACH

EA EACH FACE

EB EXPANSION BOLT

EC ELECTRICAL CONTRACTOR

EE EACH END

EEW EMERGENCY EYE WASH

EEWS EMERGENCY EYE WASH SHOWER

EFF EFFICIENCY

EJ EXPANSION JOINT

EL ELEVATION

ELAS ELASTOMERIC

ELEC ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

ENCL ENCLOSURE

ENG ENGINEER

ENTR ENTRANCE

EQ EQUAL

EQUIP EQUIPMENT

EQUIV EQUIVALENT

ERF EPOXY RESIN FLOORING

EUI ENERGY USE INTENSITY

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXIST EXISTING

Page 3: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

2 3 4 5 6 7 8 9 10

9.48.9

G

H

I

J

J.5

1.5

D

E

F

146 SF

OFFICE

H025

100 2B

93 SF

OFFICE

H022

100 1B

94 SF

OFFICE

H021

100 1B

94 SF

OFFICE

H020

100 1B

229 SF

BREAK ROOM

H023

100 3B

148 SF

COMMON ELECT

H017

300 1B

75 SF

HOLDING

H036

100 1B

96 SF

COMMAND STAFF LKR RM

H037A

50 2B

498 SF

FEMALE LOCKER RM

H013A

50 10B

282 SF

FEMALES

H013

100 3B

354 SF

MALES

H014

100 4B

1007 SF

MALE LOCKER RM

H014A

50 11B

530 SF

COURT ROOM

H035

40 14B

303 SF

ACA

H028

50 7B

439 SF

RECEPTION

H001

100 5B

123 SF

OFFICE

H002

100 2B

141 SF

OFFICE

H003

100 2B

141 SF

OFFICE

H004

100 2B

141 SF

OFFICE

H005

100 2B

158 SF

OFFICE

H006

100 2B

52 SF

STORAGE

H007 123 SF

OFFICE

H008 125 SF

CONFERENCE ROOM

H009

15 9B

515 SF

COMPUTER ROOM

H010

20 26B

75 SF

TELEPHONE ROOM

H011

100 1B

183 SF

BREAK ROOM

H012

15 13B

42 SF

STORAGE

H027

300 1S

54 SF

STORAGE

H029

300 1S

108 SF

MAIL ROOM

H030

50 3B

237 SF

OFFICE

H031

100 3B

113 SF

OFFICE

I038

117 SF

OFFICE

I039

64 SF

ELECTRICAL ROOM

I040

64 SF

TELECOM ROOM

I041

37 SF

VESTIBULE

H037

100 1B

1260 SF

LOBBY

I001

77 SF

VESTIBULE

I000

441 SF

LOBBY

I000A

15 30B

108 SF

SECURITY OFFICE

I001A

100 2B

77 SF

CELL 1

I011

79 SF

CELL 2

I012

66 SF

CELL 3

I013

66 SF

CELL 4

I014

83 SF

CELL 5

I015

83 SF

CELL 6

I016

117 SF

CELL 7

I017108 SF

CELL 8

I018125 SF

CELL 9

I019

45 SF

MEDICAL INTERVIEW

I021

100 1B

67 SF

MEDICAL INTERVIEW

I022

100 1B

37 SF

INTOX

I024

100 1B

37 SF

INTOX

I025

100 1

651 SF

INMATE WAITING

I010

15 44B

56 SF

INTEERVIEW

I027

100 1B

56 SF

INTERVIEW

I028

100 1B

598 SF

INTAKE LOBBY

I029

15 40B

58 SF

INTERVIEW

I030

100 1B

68 SF

INTERVIEW

I031

100 1B

120 SF

STORAGE

I033

300 1S

372 SF

BRIEFING

I034

100 4B

156 SF

BREAK ROOM

I035

15 11B

3471 SF

INTAKE

I037

319 SF

MENS PROCESS

I008

304 SF

WOMENS PROCESS

I009

87 SF

INTERVIEW

I046

100 1B

87 SF

INTERVIEW

I047

2299 SF

Room

I049

142 SF

JUDGES CHAMBER

H034

100 2B

179 SF

CLERK

H032

100 2B

69 SF

OFFICE

I007

100 1B

331 SF

CITY ID

I045

100 4B

10'

26'

28'

5'

13'

22'

19'

20'

7'

19'

11'

4'

16'

PD

PD

PD

PD

PD

PD

SYMBOL LEGEND

WALL SEPARATION LEGEND

0

0

0

0

- COMBINED OCCUPANT LOAD AT A GIVEN DOOR OR STAIR- TOTAL EXIT CAPACITY OF DOOR OR STAIR (THE CAPACITY OF DOORS ARE DETERMINED AS FOLLOWS: CLEAR OPENING WIDHT IN INCHES DIVIDED BY 0.2 THE CAPACITY OF STAIRS ARE DETERMINED AS FOLLOWS WIDTH IN INCHES DIVIDED BY 0.3)

- COMBINED OCCUPANT LOAD AT A GIVEN DOOR. (SUM OF THESE EQUALS TOTAL OCCUPANT LOAD)- TOTAL EXIT CAPACITY OF DOOR (THE CAPACITY OF DOORS ARE DETERMINED AS FOLLOWS: CLEAR OPENING WIDTH IN INCHES DIVIDED BY 0.2)

PD

?

- PANIC DEVICE- DOOR FIRE RATING

WALL HOURLY RATING1 = 1 HOUR2 = 2 HOUR

ROOM NAMERM # SQ.FT.

X X X- CODE ROOM TAG

OCCUPANT LOAD

OCCUPANT LOAD FACTOR

OCCUPANT TYPE

APPLICABLE CODES

THE FOLLOWING CODES WITH COLORADO SPRINGS WERE REFERENCED AND USED TO DEVELOP THIS SET OF CONSTRUCTION DOCUMENTS. SHOULD CONFLICTS ARISE BETWEEN CODES, COMPLY WITH THE MOST STRINGENT REQUIREMENT OR WRITTEN AUTHORIZATION FROM THE AUTHORITY HAVING JURISDICTION.

2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL MECHANICAL CODE2015 INTERNATIONAL PLUMBING CODE2017 NATIONAL ELECTRIC CODE2015 INTERNATIONAL ENERGY CONSERVATION CODE2010 ADA STANDARDS AS ADOPTED BY THE STATE OF COLORADO2017 ICC/ ANSI A117.1 - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES OCCUPANCY CLASSIFICATION AND USE

THE FOLLOWING BUILDING OCCUPANCIES ARE CLASSIFIED UNDER IBC CHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION:

BUSINESS GROUP B

INSTUTIONAL GROUP I-3

STORAGE ACCESSORY USE TO GROUP B*

*SECTION 508.2.3 - AGGREGATE ACCESSORY OCCUPANCIES SHALL NOT OCCUPY MORE THAT 10% OF THE FLOOR AREA OF THE STORY IN WHICH THEY ARE LOCATED.

PROJECT SUMMARY

CONSTRUCTION CLASSIFICATION: TYPE-II FRUSE AND OCCUPANCY: I-3 & BUSINESS OCCUPANCYAUTOMATIC SPRINKLER: YES

UPDATES ARE IN RESPONSE TO COVID-19 AND ARE APART OF THE CARES ACT RELIEF FUNDING. LOCATED IN COLORADO SPRINGS, THE CRIMINAL JUSTICE CENTER IS UNDERGOING AN INTERIOR RENOVATION. THE PROJECT SCOPE OF WORK INCLUDES RENOVATION WORK TO SOME OFFICE SPACE, LOCKER ROOM, TOILET ROOMS AND MAIN ENTRY LOBBY.

IBC - CHAPTER 5: GENERAL BUIDING HEIGHT AND AREASEXISTING - REMAINS UNCHANGED

IBC - TYPES OF CONSTRUCTION: SECTION 601

FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)

BUILDING ELEMENTTYPE-II FR

B

PRIMARY STRUCTURAL FRAME 0

0

0

0

0

BEARING WALLS

EXTERIOR

INTERIOR

NONBEARING WALLS AND PARTITIONS

EXTERIOR

FLOOR CONSTRUCTION AND ASSOCIATED MEMBERS

ROOF CONSTRUCTION AND ASSOCIATED MEMBERS 0

IBC - CHAPTER 6: TYPES OF CONSTRUCTIONEXISTING - REMAINS UNCHANGED

GENERAL BUILDING HEIGHTS AND AREAS

MEANS OF EGRESS SIZING

SECTION 1005:1005.3.2 OTHER EGRESS COMPONENTSTHE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH PER OCCUPANT.

SECTION 1017:1017.2 EXIT ACCESS TRAVEL DISTANCEB OCCUPANCY: 200FT WITHOUT SPRINKLER SYSTEM

SECTION 1020:1020.2 MINIMUM CORRIDOR WIDTHB OCCUPANCY: 44 INCHES

1020.4 DEAD ENDSWHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS REQUIRED, THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE THAN 20 FEET IN LENGTH.

SECTION 1006:TABLE 1006.2.1 MAXIMUM COMMON PATH OF EGRESS TRAVELB OCCUPANCY: 75FT WITHOUT SPRINKLER SYSTEM

1006.3.1 MINIMUM NUMBER OF EXITSOCCUPANT LOAD 1-500 SHALL BE NOT LESS THAN 2OCCUPANT LOAD 501-1000 SHALL BE NOT LESS THAN 3 FIRE PROTECTION & LIFE SAFETY SYSTEMS

SECTION 906: PORTABLE FIRE EXTINGUISHERS906.3.1 MAXIMUM DISTANCE OF TRAVEL TO EXTINGUISHER - 75 FEET

FEC - FIRE EXTINGUISHER LOCATION

- EGRESS PATH

- LONGEST TRAVEL DISTANCE TO EXIT

HATCHED AREA INDICATES AREASNOT IN SCOPE OF THE PROJECT

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:4

7 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

PARTIAL CODEPLAN

CP1.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

NORTHSCALE: 1/8" = 1'-0"

CODE PLAN

Page 4: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

2 3 4 5 6 7 8 9 10

9.48.9

G

H

I

J

J.5

1.5

D

E

F

3' -

4"

4' -

0"

D.07

D.07

D.01D.01

D.07

D.06

D.04D.04

D.03D.03

D.02

D.02

D.05

D.08

D.10

D.11

D.11

D.13

D.10

D.14

D.15

D.15

D.16

D.16

D.06

D.03D.03

D.09

D.09 D.09

D.17D.17

D.17D.17D.17

D.01

D.01

D.16

D.16

D.17

D.17D.17

4"

3' -

4"

3' -

4"

4"

D.18

D.18

D.18

D.18

D.18

D.18

D.18

D.09D.12

D.19D.20

D.20

D.20

D.20

D.20

D.03D.03

D.03

D.03

D.20

D.20

A10.1

41

LEGEND NOTES

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:4

2 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

DEMOLITIONFLOOR PLAN

ADA1.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

NORTHSCALE: 1/8" = 1'-0"

DEMOLITION PLAN, LEVEL 01

D.01 DEMOLISH COUNTERTOP, SINK AND P-TRAPS. CAPDOMESTIC WATER SUPPLY AND WASTE PIPING,PREPARE FOR NEW SINK.

D.02 DEMOLISH TRANSACTION COUNTER AND WINDOW.

D.03 DEMOLISH EXISTING FLOORING, PREPARE SURFACEFOR NEW SCHEDULED FINISH. RE: FINISH SCHEDULE

D.04 DEMOLISH FLOOR MOUNTED SEATING

D.05 DEMOLISH CORNER OF CONCRETE DRAINAGE SWALE TOPROVIDE SPACE FOR NEW SIDEWALK

D.06 DEMOLISH SECURITY STATION MILLWORK, RAISEDPLATFORM, COUNTERTOP, AND ALL ASSOCIATEDELECTRICAL ELEMENTS AND FIXTURES. PREPARESURFACE FOR NEW FLOOR

D.07 CUT OPENING INTO EXISTING WALL FOR SCHEDULEDDOOR

D.08 REMOVE AND PROTECT WALK-THRU METAL DETECTOR

D.09 REMOVE AND PROTECT EXISTING LOCKERS, RETURN TOOWNERS STOCK. TYP

D.10 DEMOLISH FLOOR MOUNTED BENCHES

D.11 REMOVE FIRE EXTINGUISHER AND PROTECT FORRELOCATION

D.12 DEMOLISH UPPER CABINETS

D.13 DEMOLISH WALL MOUNTED TROPHY CASE

D.14 DEMOLISH EL PASO COUNTY INSIGNIA

D.15 PROTECT EXISTING ROLL-UP SECURITY SHUTTERS

D.16 DEMOLISH TOILET PARTITIONS

D.17 DEMOLISH PLUMBING FIXTURE, CAP DOMESTIC WATERSUPPLY, WASTE & VENT PIPING. PREPARE FOR NEWPLUMBING FIXTURE

D.18 DEMOLISH EXISTING DOOR AND FRAME, VERIFY WITHOWNER IF ANYTHING TO BE SALVAGED

D.19 DEMOLISH EXISTING WINDOW

D.20 DEMOLISH EXISTING WALL

Page 5: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

3 4 5 6 7 8 9 10

G

H

I

J

J.5

1.5

D

E

F

D.21D.21

D.21D.21

D.21D.21

D.21D.21

D.21D.21

A10.1

41

LEGEND NOTES

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:4

4 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

DEMOLITIONREFLECTEDCEILING PLAN

ADA3.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

NORTHSCALE: 1/8" = 1'-0"

DEMOLITION CEILING PLAN, LEVEL 01

D.21 DEMOLISH EXISTING CEILING GRID AND TILE, SALVAGEUNDAMAGED CEILING TILES

Page 6: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

WALL TYPE NOTES

A. SEE CP SERIES SHEETS FOR LOCATIONS OF FIRE/SMOKE RATED WALLS.

B. CONSTRUCT FIRE RATED GWB PARTITIONS ACCORDING TO THE FIRE RATED ASSEMBLIES INDICATED ON THE WALL TYPE.

C. SEE DETAIL 53/A0.0 FOR GWB PARTITION SLIP CONNECTION BELOW FLOOR AND ROOF DECKS.

D. SEE DETAIL 51/A0.0 FOR CONTROL JOINT LOCATIONS AT DOOR FRAMES LOCATED IN GWB PARTITIONS.

E. SEE DETAIL 51/A0.0 FOR NON-STRUCTURAL METAL STUD FRAMING DETAILS.

F. REFER TO GENERAL NOTES ON SHEET A0.1 FOR ADDITIONAL REQUIREMENTS REGARDING GWB PARTITIONS.

S42

STUD TRACK & ANCHOR

SCHEDULED RUBBER BASE

FINISH FLOOR

5/8" GWB BOTH SIDES

MTL STUD FRAMING

SOUND BATT INSULATION

WALL ANGLE

ACOUSTICAL CEILING TILE

BASE

PLAN

HEAD

CONTINUOUS ACOUSTICAL SEALANT

3-5/8" METAL STUD FRAMINGGWB TO DECK

UNDERSIDE OF DECK

MTL RUNNER CHANNEL

SLOTTED TRACK

1"

CONTINUOUS ACOUSTICAL SEALANT

F1

STUD TRACK & ANCHOR

SCHEDULED RUBBER BASE

FINISH FLOOR

5/8" GWB BOTH SIDES

MTL STUD FRAMING

BATT INSULATION

BASE

PLAN

2-1/2" METAL STUD FRAMING

MTL RUNNER CHANNEL

HEAD

EXISTING WALLWALL ANGLE

ACOUSTICAL CEILING TILE

HEAD

MTL RUNNER CHANNELT

YP

6"

S41

STUD TRACK & ANCHOR

SCHEDULED RUBBER BASE

FINISH FLOOR

5/8" GWB

MTL STUD FRAMING

SOUND BATT INSULATION

WALL ANGLE - ACTCONDITIONS

SCHEDULED CEILING

BASE

PLAN

HEAD

CONTINUOUS ACOUSTICAL SEALANT

3-5/8" METAL STUD FRAMINGGWB TO DECK

MTL RUNNER CHANNEL6"

S43

STUD TRACK & ANCHOR

SCHEDULED RUBBER BASE

FINISH FLOOR

5/8" GWB BOTH SIDES

MTL STUD FRAMING

SOUND BATT INSULATION

WALL ANGLE

ACOUSTICAL CEILING TILE

BASE

PLAN

HEAD

CONTINUOUS ACOUSTICAL SEALANT

3-5/8" METAL STUD FRAMINGGWB WITH FIBERGLASS PANEL TO DECK

UNDERSIDE OF DECK

MTL RUNNER CHANNEL

SLOTTED TRACK

1"

CONTINUOUS ACOUSTICAL SEALANT

LEVEL 3 BULLET RESISTANT FIBERGLASS PANEL, UL752

LOBBY SIDE

SCREW BETWEEN STUDS

SLIP PLANE

TWO LAYER APPLICATION

OPTION - A

ONE LAYER APPLICATION

CL

TWO LAYER APPLICATIONONE LAYER APPLICATION

OPTION - BCL

TOP OF MTL. STUDS

NOTE: UL SYSTEM NO. HW-D-0060

NOTE: UL SYSTEM NO. HW-D-0020

3/16" x 1-1/4" SCREWS AT 2'-8" O.C. MAX. AT FLOOR ASSEMBLY ABOVE AND NO. 8x18 SCREWS AT ROOF DECK AT 2'-8" O.C. MAX.

BOTTOM OF MTL. ROOF DECK OR PRECAST FLOOR/CEILING SLAB

TOP OF MTL. STUDS

STABILIZE STUDS AT TOP W/ CONT. CHANNEL AND BRIDGE CLIP AT EACH STUD

SEE WALL TYPE AS SCHEDULED

CONT. SEALANT BOTH SIDES - FIRE RATED SEALANT AT RATED WALLS. ACOUSTICAL SEALANT AT SOUND WALLS.

16 GA. RECEIVER CHANNEL CONT. W/ 2-1/2" MIN. LEGS NO CONNECTION BETWEEN CHANNEL AND STUDS BELOW

FIRE SAFING INSULATION AT RATED WALLS, SOUND ATTENUATION BLANKETS AT SOUND WALLS

GWB COVER PIECE(S) SCRIBE TO CONFORM TO THE SHAPE OF METAL DECK W/ SLIP REQUIREMENTSGWB AND ADDITIONAL FINISHES PER WALL TYPE

BLANKET INSULATION PER WALL TYPE

3/16" x 1-1/4" SCREWS AT 2'-8" O.C. MAX. AT FLOOR ASSEMBLY ABOVE AND NO. 8x18 SCREWS AT ROOF DECK AT 2'-8" O.C. MAX

BOTTOM OF MTL. ROOF DECK OR FLOOR SLAB

MTL. STUD WALL FRAMING, SEE WALL TYPE FOR SIZE, SPACING AND GAUGE OF STUDS. STABILIZE AT TOP W/ CONT. CHANNEL AND BRIDGE CLIP AT EACH STUD.

TWO LAYER APPLICATION

OPTION - A

ONE LAYER APPLICATION

CL

NOTE: UL SYSTEM NO. HW-D-0060HEAD OF WALL PERPENDICULAR TO FLUTES HEAD OF WALL PARALLEL TO FLUTES

TWO LAYER APPLICATION

OPTION - A

ONE LAYER APPLICATION

CL

NOTE: UL SYSTEM NO. HW-D-0060

FIRE SAFING INSULATION AT RATED WALLS, SOUND ATTENUATION BLANKETS AT SOUND WALLS

HEAD OF WALL PARALLEL TO FLUTES

14 GA CONT. PLATE

HEAD OF WALL PERPENDICULAR TO FLUTES

TWO LAYER APPLICATIONONE LAYER APPLICATION

OPTION - BCL

NOTE: UL SYSTEM NO. HW-D-0020

3/16" x 1-1/4" SCREWS AT 2'-8" O.C. MAX. AT FLOOR ASSEMBLY ABOVE AND NO. 8x18 SCREWS AT ROOF DECK AT 2'-8" O.C. MAX.

BOTTOM OF MTL. ROOF DECK OR PRECAST FLOOR/CEILING SLAB

TOP OF MTL. STUDS

STABILIZE STUDS AT TOP W/ CONT. CHANNEL AND BRIDGE CLIP AT EACH STUD

HEAD OF WALL PARALLEL TO FLUTES

Z-FURRING @ 24" O.C. TO STABILIZE TRACK

TWO LAYER APPLICATIONONE LAYER APPLICATION

OPTION - B CL

NOTE: UL SYSTEM NO. HW-D-0020

3/16" x 1-1/4" SCREWS AT 2'-8" O.C. MAX. AT FLOOR ASSEMBLY ABOVE AND NO. 8x18 SCREWS AT ROOF DECK AT 2'-8" O.C. MAX.

BOTTOM OF MTL. ROOF DECK OR PRECAST FLOOR/CEILING SLAB

TOP OF MTL. STUDS

STABILIZE STUDS AT TOP W/CONT. CHANNEL AND BRIDGECLIP AT EACH STUD

HEAD OF WALL PARALLEL TO FLUTES

14 GA CONT. PLATE

FIRE SAFING INSULATION AT RATED WALLS, SOUND ATTENUATION BLANKETS AT SOUND WALLS

FIRE SAFING INSULATION AT RATED WALLS, SOUND ATTENUATION BLANKETS AT SOUND WALLS

LONG LEG DEFLECTION COMPENSATING HEAD TRACK: SECURE TO DECKING ABOVE

FIRE SAFING INSULATION AT RATED WALLS, SOUND ATTENUATION BLANKETS AT SOUND WALLS

LONG LEG DEFLECTION COMPENSATING HEAD TRACK: SECURE TO DECKING ABOVE

LONG LEG DEFLECTION COMPENSATING HEAD TRACK: SECURE TO DECKING ABOVEINTUMESCENT MASTIC

FIREPROOFING; EXTEND MIN 1/2" ONTO GWB & DECKING

SEE WALL TYPE AS SCHEDULED

SEE WALL TYPE AS SCHEDULED

INTUMESCENT MASTIC FIREPROOFING; EXTEND MIN 1/2" ONTO GWB & DECKING

INTUMESCENT MASTIC FIREPROOFING; EXTEND MIN 1/2" ONTO GWB & DECKING

5/8

" M

AX

.

5/8"

MA

X

0' -

3"

0' -

1"

0' -

2 1

/2"0

' - 0

1/2

"

0' -

0 1

/2"

0' -

3"

0' -

1"

0' -

2 1

/2"

5/8

" M

AX

TOP OF MTL. STUDS

CONT. SEALANT BOTH SIDES - FIRE RATED SEALANT AT RATED WALLS. ACOUSTICAL SEALANT AT SOUND WALLS.

16 GA. RECEIVER CHANNEL CONT. W/ 2-1/2" MIN. LEGS NO CONNECTION BETWEEN CHANNEL AND STUDS BELOW

GWB COVER PIECE(S) SCRIBE TO CONFORM TO THE SHAPE OF METAL DECK W/ SLIP REQUIREMENTSGWB AND ADDITIONAL FINISHES PER WALL TYPE

3/16" x 1-1/4" SCREWS AT 2'-8" O.C. MAX. AT FLOOR ASSEMBLY ABOVE AND NO. 8x18 SCREWS AT ROOF DECK AT 2'-8" O.C. MAX

BOTTOM OF MTL. ROOF DECK OR FLOOR SLAB

MTL. STUD WALL FRAMING, SEE WALL TYPE FOR SIZE, SPACING AND GAUGE OF STUDS. STABILIZE AT TOP W/ CONT. CHANNEL AND BRIDGE CLIP AT EACH STUD.

SCREW BETWEEN STUDS

SLIP PLANEBLANKET INSULATION PER WALL TYPE TOP OF MTL. STUDS

CONT. SEALANT BOTH SIDES - FIRE RATED SEALANT AT RATED WALLS. ACOUSTICAL SEALANT AT SOUND WALLS.

16 GA. RECEIVER CHANNEL CONT. W/ 2-1/2" MIN. LEGS NO CONNECTION BETWEEN CHANNEL AND STUDS BELOW

GWB COVER PIECE(S) SCRIBE TO CONFORM TO THE SHAPE OF METAL DECK W/ SLIP REQUIREMENTSGWB AND ADDITIONAL FINISHES PER WALL TYPE

3/16" x 1-1/4" SCREWS AT 2'-8" O.C. MAX. AT FLOOR ASSEMBLY ABOVE AND NO. 8x18 SCREWS AT ROOF DECK AT 2'-8" O.C. MAX

BOTTOM OF MTL. ROOF DECK OR FLOOR SLAB

MTL. STUD WALL FRAMING, SEE WALL TYPE FOR SIZE, SPACING AND GAUGE OF STUDS. STABILIZE AT TOP W/ CONT. CHANNEL AND BRIDGE CLIP AT EACH STUD.

SLIP PLANE

BLANKET INSULATION PER WALL TYPE

SCREW BETWEEN STUDS

0' -

2 1

/2"

0' -

1"

0' -

3"

0' -

0 1

/2" 5/

8" M

AX

5/8"

MA

X

CONTROL JOINT LOCATIONS

SILL STUDS WITH CRIPPLE STUDS BELOW AT WINDOW OPENING

CRIPPLE STUDS ABOVE HEAD RUNNERSEE NOTE BELOW

JAMB STUDS

HEADER STUDS

STIFFENER STUDS

TOP RUNNER

BOTTOM RUNNER

C

TYP. METAL STUD FRAMING AT FRAME OPENINGNO SCALE

B

5/8" GYPSUM WALLBOARD OVER 6" COLD FORM METAL FRAMING

LINE OF GYPSUM WALLBOARD RETURN AT OPENING BELOWOPENING

BELOW

TEAR AWAY 'L' BEAD TRIM NO FASTENERS INTO RUNNER TRACK

SCALE: 1-1/2" = 1'-0"

TYP. VERT. SLIP CONTROL JOINT D

SM 'L' TRIM ON VERTICAL SLIP JOINT BOTH SIDES

D

AT EXTERIOR WALL SEE ELEVATIONS FOR LOCATIONS

SPRAY FOAM INSULATION

E/F

OPENING WIDTH

0' TO 5'-0"

10'-1" TO 15'-0"5'-1" TO 10'-0"

INTERIOR HEADER SCHEDULE

FRAMING MEMBERS

TWO - 8" x 20 GATWO - 10" x 20 GA

TWO - 3-5/8" x 20 GA

TRACK (SAME GAUGE AS HEADER) (TYP)

BOX LINTEL (HEADER) SEE SCHEDULE BELOW (TYP)

SEE PLAN FOR WALL TYPE (TYP)

#12 SCREWS AT 16" O.C. TYP.

SPAN UP TO 10'-0"

SPAN GREATER THAN 10'-0"

NOTE:1. HEADER SHALL BE UNPUNCHED AND OF THE SIZE AND GAUGE LISTED.

E

F

TRACK AT TOP AND BOTTOM OF HEADER

CONTROL JOINT LOCATIONS

TOP TRACK

CRIPPLE STUDS ABOVE HEADERTOP TRACK - SEE NOTE BELOW

HEADER STUDS

STIFFENER STUDS

BEARING STUD

BOTTOM TRACK

NOTE: ABOVE HEADER, PROVIDE 1/2" MIN CLEAR SPACE BETWEEN CRIPPLESTUDS AND STIFFENER STUDS BOTH SIDES OF ALL DOOR OPENINGS

TYP METAL STUD FRAMING AT DOOR OPENING

TYP GWB CONTROL JOINT ABOVE

GWB/METAL STUD WALL -SEE PLAN FOR WALL TYPE

DOOR FRAME BELOW

CONTROL JOINT

CRIPPLE STUDS @ 16" OC

STIFFENER STUDS

NOTE:AT DOUBLE LAYER GWB LOCATIONSMAINTAIN 1/2" CLEAR SPACE ATFIRST LAYER AND CONTROL JOINTAT SECOND LAYER

0' - 0 1/2"

SCALE: 1-1/2" = 1'-0"

NO SCALE

C

C

A

E/F

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:0

3 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

WALL TYPES

A0.0

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

SCALE: 1 1/2" = 1'-0"

Wall Types

SCALE: 3" = 1'-0"A0.0

53 STUD WALL SLIP CONNECTIONS AT RATED WALLS - FIRE STOP @ GWBSCALE: 1 1/2" = 1'-0"A0.0

51 METAL STUD OPENINGS AND CONTROL JOINTS

Page 7: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

2 3 4 5 6 7 8 9 10

9.48.9

G

H

I

J

J.5

1.5

D

E

F

LOCKER COUNT

MALE = 420FEMALE = 252COMMAND STAFF = 36

TOTAL = 708

TYP6' - 0"

10.02

10.04

09.0209.02

32.02

32.01TY

P

5' -

0"

32.04

32.03

36

A10.1

09.05

A2.1

12

OFFICE

H025

OFFICE

H022

OFFICE

H021

OFFICE

H020

TOILET

H024

BREAK ROOM

H023

COMMONELECT

H017

HOLDING

H036

COMMANDSTAFF LKR RM

H037A

FEMALELOCKER RM

H013A

FEMALES

H013

MALES

H014

MALELOCKER RM

H014A

COURT ROOM

H035

ACA

H028

RECEPTION

H001

OFFICE

H002

OFFICE

H003

OFFICE

H004

OFFICE

H005

OFFICE

H006

STORAGE

H007

OFFICE

H008

CONFERENCEROOM

H009

COMPUTERROOM

H010

TELEPHONEROOM

H011

BREAK ROOM

H012

STORAGE

H027

STORAGE

H029

MAIL ROOM

H030

OFFICE

H031

CORRIDOR

H000

OFFICE

I038

OFFICE

I039

ELECTRICALROOM

I040

TELECOMROOM

I041

MENS TOILET

I042

WOMENSTOILET

I043

AH022

A2.1

51

A2.1

53

AH014A

AH028

VESTIBULE

H037 AH037A

AH023

AH021

XH017

XH020

XH024

XH023A

XH013 XH014

XH037

XH029A XH029BXH027

AI003

AI002

AI001

LOBBY

I001

VESTIBULE

I000

LOBBY

I000A

SECURITYOFFICE

I001A

AI001A

XI038

XI039

XI040

XI041

X1042

XI043

XH012A XH012B XH011

XH007

XH001BXH010

XH008 XH009

XH001A

XH006A XH005 XH004 XH003

XH002B

XH002A

XH006B

XH035B XH035A

XH034B

XH034A

XH033

XH032

XH036A

XI006A

XI006B XI007XH035C

XI045

XI004 X044A

XI046

XI047

XI044C

XI008A

XI009A

XI008B

XI009B

XI049

XI011

XI012

XI013

XI014

XI015

XI016XI017BXI018BXI019BXI020

XI017AXI018AXI019A

XI026B

XI022B

XI022A

XI021

XI023

XI044A

XI029B

XI037

X1029A

1006

XI026A

X1027X1028

XI024 XI025

XI026C

XI031 XI030

1008

XI033

XI036

XI034

XI035

XI032

CELL 1

I011

CELL 2

I012

CELL 3

I013

CELL 4

I014

CELL 5

I015

CELL 6

I016

CELL 7

I017

CELL 8

I018

CELL 9

I019

JANITORS

I020

MEDICALINTERVIEW

I021

MEDICALINTERVIEW

I022

JANITORS

I023

INTOX

I024

INTOX

I025

SALLYPORT

I026

INMATEWAITING

I010

INTEERVIEW

I027

INTERVIEW

I028

INTAKE LOBBY

I029

INTERVIEW

I030

INTERVIEW

I031

INTAKE

I037

STORAGE

I033

BRIEFING

I034

BREAK ROOM

I035

TOILET

I036

INTAKE

I037

MENSPROCESS

I008

WOMENSPROCESS

I009

INTERVIEW

I046

INTERVIEW

I047INMATEWAITING

I044Room

I049

JUDGESCHAMBER

H034

CLERK

H032

TOILET

H033

SALLYPORT

I053

OFFICE

I007

CITY ID

I045

SALLYPORT

I004

VEST

I004A

CORRIDOR

H036A

XI044B

XI000A

XI000B

32.03

32.03 32.03 32.0332.03

32.03

32.03

32.03

32.03

32.03

32.03

32.0332.03

32.03

32.03

EQ EQ

08.02

10.04

A10.1

41

49'-7

" VE

RIF

Y

LEGEND NOTES

GENERAL NOTES

A. GENERAL NOTES APPLY TO ALL SHEETS.B. DIMENSIONS ARE ACTUAL AND ARE TO FACE OF STUDS, FACE

OF CONCRETE WALLS, FACE OF CMU WALLS, FACE OF FRAMES, OR CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE.

C. SEE SHEET A0.0 FOR WALL TYPES. D. ALL INTERIOR STUD WALLS SHALL EXTEND TO UNDERSIDE OF

FLOOR OR ROOF DECK ABOVE UNLESS NOTED OTHERWISE. SEE REFLECTED CEILING PLAN NOTES.

E. PROVISIONS SHALL BE MADE AT ALL FULL HEIGHT NON-BEARING WALLS FOR 1-INCH VERTICAL MOVEMENT OF THE BUILDING STRUCTURE WITHOUT TRANSFER OF COMPRESSIVE LOADS TO WALL. FILL IRREGULARITIES BETWEEN TOP OF WALL AND DECK ABOVE WITH FIRE SAFING INSULATION OR FIRE STOPPING MATERIALS AS REQUIRED TO MEET FIRE RATING OF RESPECTIVE WALLS. SEE DETAILS 53/A0.0

F. ALL PENETRATIONS THROUGH WALLS SHALL BE SEALED WITH THRU-WALL FIRE STOPPING MATERIAL AS REQUIRED TO ACHIEVE THE RESPECTIVE FIRE-RESISTIVE RATING AND SMOKE STOPPAGE. SEE SPECIFICATION SECTION 078413.

G. FURNISH AND INSTALL FIRE-TREATED WOOD BLOCKING OR METAL BACKING PLATE IN METAL STUD PARTITIONS FOR THE PROPER ANCHORAGE OF ALL WALL ATTACHED ITEMS; I.E. TOILET ACCESSORIES, CASEWORK, MILLWORK, WALL-MOUNTED FIXTURES, MARKER BOARDS, TACK BOARDS, DOOR STOPS, AUDIO VISUAL BRACKETS, ETC.

H. INCLUDE ALL OWNER FURNISHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTOR INSTALLED ITEMS IN THE CONSTRUCTION SCHEDULE, AND SHALL COORDINATE WITH THE OWNER TO ACCOMMODATE THESE ITEMS.

I. COORDINATE ALL MECHANICAL CHASE SIZES WITH THE MECHANICAL CONTRACTOR.

J. EXTEND FURRING CHANNELS AND GYPSUM BOARD UP 4 INCHES ABOVE FINISHED CEILING ON CMU WALLS.

NOTE: LIGHTING LAYOUT TO BE REARRANGED PER NEW FLOOR PLAN, REBALANCE HVAC SYSTEM TO ACCOMODATE THE NEW FLOOR PLAN LAYOUT.

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:0

7 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

FLOOR PLAN

A1.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

NORTHSCALE: 1/8" = 1'-0"

FLOOR PLAN, LEVEL 01

08.02 CARD ACCESS CONTROLLED DOOR

09.02 NEW VCT FLOORING, RE: FINISH PLAN AND SCHEDULE

09.05 NEW EL PASO COUNTY INSIGNIA - 8'-0" DIA

10.02 SECURITY EQUIPMENT, OWNER PROVIDED CONTRACTORINSTALLED

10.04 RETRACTABLE SECURITY STANCHION, OWNERPROVIDED CONTRACTOR INSTALLED

32.01 NEW SIDEWALK

32.02 42" HIGH GUARDRAIL

32.03 NEW ARCHITECTURAL BOLLARD, RE: SPECIFICATIONS,6'-0" SPACING TYP

32.04 NEW CONCRETE DRAINAGE SWALE

Page 8: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

TOILET ACCESSORIES

ABBREVIATIONSABBREV DESCRIPTION

GB-1 GRAB BAR (BACK WALL) - SALVAGE AND REINSTALLGB-2 GRAB BAR (SIDE WALL) - SALVAGE AND REINSTALLGB-4 GRAB BAR (AMBULATORY STALL) - SALVAGE AND REINSTALLGB-5 GRAB BAR (SHOWER)MR MIRROR - 24"X36" (CFCI)PTD PAPER TOWEL DISPENSER (CFCI)SD LIQUID SOAP DISPENSER (CFCI)SCR SHOWER CURTAIN ROD - SALVAGE AND REINSTALLSND SANITARY NAPKIN DISPOSAL (CFCI)TTD SURFACE MOUNTED TOILET PAPER DISPENSER (CFCI)

MR URINAL URINAL

(ACC)

PTD/R

(ACC)

LAV LAV TTD SD

WC

(ACC)

WC

(ACC)

SND

RH

(ACC)

RH-1 MBH US SSS

ADA SAD 2010 - 604, 609ANSI A117.1 2003 - 604.5.1

ADA SAD2010 - 604.8.3

ADA SAD2010 - 603.4

ADA SAD2010 - 606.1

ADA SAD2010 - 606.3

ADA SAD2010 - 604.7

ADA SAD2010 - 606.1

ADA SAD2010 - 605.2

ADA SAD2010 - 603.3

ADULT MOUNTING HEIGHTS

TO

B.O

.4

0"

MA

X

2' -

0" 17

" M

AX

T.O

. C

ON

TR

OL

S4

8"

MA

X

34

" M

AX

27

" M

IN

8" MIN

11" MIN 9"

MIN

34

" M

AX

27

" M

IN

9"

MIN

TO

DIS

PE

NS

ER

15

" M

IN T

O 4

8"

MA

X

T.O

. C

ON

TR

OL

S4

4"

MIN

- 4

8"

MA

X

FLOOR MOUNTED WC59" MIN AT

WALL HUNG WC56" MIN AT

12" MAX42" MIN

C TO REAR WALL41" MAX - 39" MINL

GB-3

GB-2

GB-1

T.O

. G

RA

B B

AR

33

" M

IN -

36

" M

AX

7" TO 9"

1' -

6"

B.O

. G

RA

B B

AR

41

" M

AX

- 3

9"

MIN

18

" M

IN

48

" M

AX

60" MIN

1' - 6"

12" MIN 24" MIN

36" MIN

1' -

6"

T.O

. G

RA

B B

AR

33

" M

IN -

36

" M

AX

2' -

4"

5' -

9"

48

" M

AX 6' -

0"

48

" M

AX

40

" M

IN

15

" M

IN

RE

FL

EC

TIN

GS

UR

FA

CE

A. ACCESSIBLE URINAL SHALL PROVIDE CLEAR FLOOR SPACE PER ADA SAD 2010 - 605.3

B. ACCESSIBLE WATER CLOSETS SHALL PROVIDE CLEAR SPACE PER ADA SAD 2010 - 604.3.1

C. ACCESSIBLE LAVATORIES AND SINKS SHALL PROVIDE CLEAR SPACE PER ADA SAD 2010 - 606.2

D. ACCESSIBLE TOILET ROOMS SHALL PROVIDE A TURNING SPACE OF 60 INCHES IN DIAMETER PER ADA SAD 2010 - 304.3.1

E. ACCESSIBLE TOILET PARTITIONS SHALL COMPLY WITH ADA SAD 2010 - 604.8.1

F. EXPOSED PIPES AND SURFACES UNDER LAVATORIES AND SINKS SAHLL BE INSULATED PER ADA SAD 2010 - 606.5

GENERAL NOTES FOR ACCESSIBILITY

2 3 4

E

F

1' - 8 1/8"24 LOCKERS CENTERED

12' - 1 1/4" 1' - 8 1/8"

1' -

2 3

/4"

5' -

8 1

/4"

2' -

6 3

/4"

12

LO

CK

ER

S C

EN

TE

RE

D

6' -

1 1

/4"

2' -

6 3

/4"

12

LO

CK

ER

S C

EN

TE

RE

D

6' -

1 1

/4"

1' -

3 3

/8"

1' -

3 3

/8"

2412

1218

18

42

18

18

18

MIN

1' -

0"

EQ 6' - 0" EQEQ

1' -

3"

EQ

EQ

1' -

3"

EQ

EQ 6' - 0" EQ

EQ

1' -

3"

EQ 6' - 0"

S41

S41

S41

S41

S41

S41 S41

S41

S41

S41

S41

S41

S41

1' - 2 7/8"42 LOCKERS CENTERED

21' - 1 1/4" 6 7/8"

28

LO

CK

ER

S C

EN

TE

RE

D1

4' -

1 1

/4"

4' -

0 1

/8"

4' -

0"

2' -

0"

4' -

0"

1' -

3 1

/2"

42

28

20 36

18

2' - 4" 1' - 3" 2' - 4" 2' - 8" 2' - 4" 1' - 3" 2' - 4" 2' - 8" 5' - 0"

6' -

0"

3' -

0"

6' -

0"

24

24

1' -

3"

2' -

4"

2' -

6"

3' -

5"

4' - 0" 2' - 0" 4' - 0" 2' - 0"

28

14

1' - 9 1/4"

1' -

9 1

/4"

24 24

18

1' - 3" 2' - 4" 2' - 6" 2' - 4" 1' - 3" 2' - 4" 1' - 4"

18 18

30 30

S42

S42

S42

S41

S41S41

S41

S41

S41

A10.1

31

A10.1

33

12

A10.1

21

OFFICE

H025

OFFICE

H022

OFFICE

H021

OFFICE

H020

BREAK ROOM

H023

COMMONELECT

H017

HOLDING

H036

COMMANDSTAFF LKR RM

H037A

FEMALELOCKER RM

H013A

FEMALES

H013

MALES

H014

MALELOCKER RM

H014A

COURT ROOM

H035

STORAGE

H027

CORRIDOR

H000

AH022

AH021

XH025

AH023

XH020

XH017

XH013 XH014XH014A

XH027

XH037

AH037A

AH014A

XH014A

XH035B

XH035C

713

A11.132 31

30

30

S42S42

S42

4' -

6"

8' - 4"

ALIGN

A11.135 34

24

10.06

10.0622.02

22.03

22.03

22.03

10.06

10.06

22.01

22.01

22.01

22.01

10.01

10.05

10.0510.05

10.05

10.05

10.05

10.05

10.05

10.05

10.05

10.0510.0510.05

10.05

10.05

10.05

10.05

10.05

10.05 10.05

10.05

10.05

10.05

10.05

10.05

10.05

10.0510.08

10.01

10.01

10.01

10.08 10.08

10.08

10.08

10.01

10.01

10.01

08.01

WA

LL IN

FIL

L

3' -

4"

3"

07.01

WA

LL IN

FIL

L

3' -

4"

3"

07.01

07.01

4' - 0" 2' - 4"

10.05

EQ

1' -

3"

EQ

6' -

0"

3' -

0"

12

' - 0

"

12

' - 0

"

08.05

08.07

08.07

10.10

10.09

10.09

10.11

10.11

10.11

10.11

WALL INFILL3' - 4"

07.01

10.09

10.09

10.12

10.12

10.12

10.12

ALIGN

ALIGN

A10.1

13

S41

S41

A10.1

14

ADJUST EXISTING PLUMBING LINESFOR INSTALLATION OF NEW FIXTURE

EQ

EQ

6

H

I

56

A10.1

56

A10.1

45

A10.1

46

A10.1

A10.1

26

A10.1

16

A9.1

5

A9.14

VERIFY11' - 3 7/8"

9' -

10

"46

A10.1

AI001

AI001A

S43

S43

A11.1

51

52

LOBBY

I000A

SECURITYOFFICE

I001A

LOBBY

I001

INTAKE

I037

OFFICE

I038

VESTIBULE

I000

A11.153

54

4' -

0"

2' -

1"

2' - 1" 7' - 6"

6' -

8"

45

A10.1

09.03

08.04

08.04

08.02

08.0408.04

10.03

09.04

08.03

08.03

09.01

10.07

10.07

W1 W1

W2

W2

W4

W5

3' - 9" 3' - 9"

2' - 6" 2' - 6"

LINE OF SOFFIT ABOVE, ALIGN ALUMUNUM FRAMEWITH LINE OF SOFFIT

EQ EQ

08.06

28.01

O

M

S

28.02

DASHED LINE INDICATES

OPENING TO BE REMOTELY

RELEASED BY PUSH BUTTON

6

A11.1

14

11

1312

A11.1

21

24

23

22

SND

TTD

TTD

WOMENS

I003

MENS

I002

AI003

AI002

INSTALL NEW FIXTUREAT EXISTING FIXTURELOCATION

INSTALL NEW FIXTUREAT EXISTING FIXTURELOCATION

MRMR

INSTALL NEW FIXTUREAT EXISTING FIXTURELOCATION

10.06

10.06

22.03

22.03

22.01

22.01

22.02

10.11

10.11

08.02

08.02

O

M

S

O

M

S

LEGEND NOTES

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:1

3 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

LARGE SCALEPLANS

A2.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

SCALE: 1/4" = 1'-0"A2.1

12 ENLARGED TOILET AND LOCKER ROOM PLAN

SCALE: 1/4" = 1'-0"A2.1

51 ENLARGED FLOOR PLANSCALE: 1/4" = 1'-0"A2.1

53 ENLARGED TOLET ROOM PLAN

07.01 INFILL EXISTING OPENING TO MATCH EXISTING WALLCONSTRUCTION

08.01 PROVIDE TRANSLUCENT FILM ON INSIDE OF WINDOWSURFACE

08.02 CARD ACCESS CONTROLLED DOOR

08.03 STOREFRONT WITH TRANSLUCENT FILM

08.04 BULLET RESISTANT TRANSACTION WINDOW ANDPASS-THRU TRAY

08.05 ,NEW SCHEDULED DOOR WITH KEY ACCESS

08.06 REMOTE ACCESS CONTROL

08.07 NEW SCHEDULED DOOR OPENING

09.01 BULLET RESISTANT WALL AND GLAZING

09.03 ADD BULLET RESISTANT LAYER TO EXISTING WALL

09.04 PATCH & TOUCH UP WALL AS NECESSARY TO MATCHADJACENT WALL FINISH AND TEXTURE

10.01 72"L X 15"W X 17 1/2"H WOOD BENCH WITH PEDESTALS

10.03 TRANSACTION DRAWER

10.05 NEW LOCKERS WITH SLANTED TOP AND COVERED BASE,VERIFY NUMBERING SEQUENCE WITH OWNER, TYPICAL

10.06 NEW TOILET PARTITION

10.07 OFCI WALL MOUNTED TV'S

10.08 48"L X 15"W X 17 1/2"H WOOD BENCH WITH PEDESTALS

10.09 24"X36" MIRROR

10.10 EXISTING BENCH TO REMAIN

10.11 SURFACE MOUNTED SOAP DISPENSER

10.12 EXISTING SHOWER PANS TO REMAIN

22.01 NEW SINK, CONNECT TO EXISTING DOMESTIC WATER,WASTE AND VENT PIPING

22.02 NEW URINAL, CONNECT TO EXITING DOMESTIC WATER,WASTE AND VENT PIPING

22.03 NEW WATER CLOSET, CONNECT TO EXISTING DOMESTICWATER, WASTE AND VENT PIPING

28.01 MOUNT PUSH BUTTON UNDER MILLWORK FOR REMOTERELEASE OF OPENING AI001. CONTRACTOR TOCOORDINATE WITH OWNERS REPRESENTATIVE ANDMILLWORK CONTRACTOR FOR FINAL LOCATION

28.02 INTEGRATE OPENING WITH PLC SYSTEM. CARD ACCESSSYSTEM TO OPEN DOOR VIA PLC SYSTEM DRY CONTACT.DOOR POSITION SWITCH AND OVERHEAD MOTIONSENSOR DEVICES TO INTEGRATE INTO PLC AS WELL.COORDINATE INTERFACE WITH OWNERS SECURITYELECTRONICS MAINTENANCE STAFF

Page 9: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

A. REFLECTED CEILING PLAN GENERAL NOTES APPLY TO ALL REFLECTED CEILING PLAN SHEETS.

B. ALL CEILING GRIDS/PANELS SHALL BE CENTERED IN EACH ROOM UNLESS NOTED OTHERWISE.

C. CEILING HEIGHTS ARE NOTED ON THE REFLECTED CEILING PLAN UNLESS NOTED OTHERWISE.

D. ALL ELECTRICAL FIXTURES, SPEAKERS, SMOKE AND THERMAL DETECTORS, MECHANICAL GRILLES, SPRINKLER HEADS, ETC. SHALL BE CENTERED BETWEEN CEILING GRIDS UNLESS NOTED OTHERWISE. SPRINKLER HEADS SHALL BE WITHIN A 3" RADIUS CENTERED BETWEEN CEILING GRIDS.

E. IN ACOUSTICAL CEILING PANELS WITH SCORE IN THE CENTER, CENTER DEVICES REFERENCE IN NOTE D IN ONE HALF OF THE TILE. DO NOT LOCATE ON THE SCORE. FOR APC WITH MULTIPLE SCORED PATTERNS, COORDINATE LOCATION WITH THE ARCHITECT.

F. PROVIDE SUSPENSION SYSTEM AROUND ELECTRICAL FIXTURES, MECHANICAL GRILLES, DIFFUSERS, ETC. AT ACOUSTICAL PANEL CEILINGS.

G. ALL DIMENSIONS ON REFLECTED CEILING PLANS ARE ACTUAL AND ARE TO THE FOLLOWING UNLESS NOTED OTHERWISE:a. FACE OF FINISHED WALLb. FACE OF FINISHED BULKHEADSc. CENTERLINE OF COLUMNSd. CENTERLINE OF TEES

H. IN AREAS WITH EXPOSED STRUCTURE CEILINGS, COORDINATE EXACT LOCATIONS OF MECHANICAL GRILLES, DIFFUSERS, DUCTWORK AND ELECTRICAL FIXTURES WITH EACH REPRESENTATIVE SUBCONTRACTOR.

I. ALL WALLS EXTEND TO UNDERSIDE OF DECK EXCEPT THOSE SHOWN SHADED IN WHICH GYPSUM BOARD OR MASONRY EXTENDS MIN 4" ABOVE FINISHED CEILING. ALL METAL STUDS EXTEND TO UNDERSIDE OF FLOOR OR ROOF DECK.

REFLECTED CEILING PLANGENERAL NOTES

3 4 5 6 7 8 9 10

G

H

I

J

J.5

1.5

D

E

F

EXIST

9' - 0"

EXIST

9' - 0"

APC-1

9' - 0"

APC-1

9' - 0"

APC-1

9' - 0"

APC-1

9' - 0"

GYP

8' - 10"

GYP

8' - 10"

EXIST

8' - 0"

EXIST

8' - 0"

EXIST

8' - 0"

09.0709.07

09.0709.07

09.07

09.07

GYPSUM BOARDBULKHEAD

GYPSUM BOARDBULKHEAD

EXIST

15' - 0"

EXIST

8' - 0"

EXIST

9' - 0"

EXIST

9' - 0"

GYP

8' - 10"

GYPSUM BOARDBULKHEAD

LEGEND NOTES

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:1

7 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

REFLECTEDCEILING PLAN

A3.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

NORTHSCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN

09.07 NEW CEILING GRID AND CEILING TILE

Page 10: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

DOOR AND FRAME SCHEDULEGENERAL NOTES

A. ALL HOLLOW METAL FRAMES SET IN METAL STUD WALLS SHALL BE FILLED WITH MINERAL WOOL BLANKET INSULATION.

B. GLASS TYPES FOR DOORS ARE INDICATED IN THE DOOR GLAZING COLUMN OF THE DOOR AND FRAME SCHEDULE. GLASS TYPES FOR FRAMES ARE INDICATED ON THE FRAME ELEVATIONS OR IN THE SPECIFICATIONS.

C. TO COORDINATE EXACT SIZE OF DOOR WITH MANUFACTURER.D. FRAME MANUFACTURER SHALL COORDINATE LOCATIONS OF ALL

CONCEALED CONDUIT AND J-BOXES REQUIRED FOR SECURITY SYSTEM HARDWARE PRIOR TO MANUFACTURING OF HOLLOW METAL FRAMES AND COORDINATE WITH SECURITY HARDWARE AND DEVICES.

E. PROVIDE HEAD RECEIVERS AT ALUMINUM STOREFRONTS AND CURTAIN WALLS AS REQUIRED FOR STRUCTURAL DEFLECTION ALLOWANCE.

F. SEE SPECIFICATIONS HARDWARE SECTION FOR HARDWARE SETS NOTED IN DOOR AND FRAME SCHEDULE.

NOTE:

TTG = 1/4" TRANSLUCENT TEMPERED GLASSCTG= 1/4" CLEAR TEMPERED GLASSGL-1= BULLET RESISTANT GLASSWD = WOODHM = HOLLOW METAL

A B

3' -

7"

2' -

9"

4" 6"

SEE SCHEDSEE SCHED

SE

E S

CH

ED

SE

E S

CH

ED

1' -

0"

8"

SE

E S

CH

ED

SEE SCHED

6" 6"

C

TTG

A

SE

E S

CH

ED

2"

2" SEE SCHED 2"

5/8" GYPSUM BOARD BOTH SIDES, TYP

3-5/8" MTL STUD

TOP TRACK HEADER

SEALANT BOTH SIDES, TYP

1/2"

HOLLOW METAL FRAME,SEE SCHEDULE

DOOR, SEE SCHEDULE

1/2"

FILL HM FRAME WITH MINERAL WOOL INSULATION

DOOR, SEE SCHEDULE

JAMB ANCHOR

HOLLOW METAL FRAME,SEE SCHEDULE

DOUBLE STUDS AT JAMB

5/8" GYPSUM BOARD

SEALANT BOTH SIDES, TYP

1/2

"1

/2"

2" 2' - 2" 2"

2"

4' -

0"

2' -

10

"

GL-1

W1

4' -

3"

SPEAK-THRU

2"

4' -

0"

2' -

10

"

2" 3' - 0" 2"

4' -

3"

SP[EAK-THRUGL-1

W2

2" 3' - 0" 2" 3' - 0" 2" 3' - 0" 4"

9' - 10"

2"

7' -

8"

2"

8' -

0"

CTG CTG CTG

W4

4" 3' - 0" 2" 3' - 0" 2" 3' - 0" 2"1' - 3 7/8"

2"

2"

7' -

8"

2"

8' -

0"

VERIFY11' - 3 7/8"

LINE OF GYPSUM SOFFITABOVE, ALIGN FRAME WITHSOFFIT

W5

TTG TTG TTG TTG

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:2

0 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

DOOR ANDFRAMESCHEDULE

A9.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

_DOOR AND FRAME SCHEDULE_

NUMBER

PANEL FRAME

FIRERATING HARDWARE SET

DETAILS

COMMENTSNO. OFPANELS WIDTH HEIGHT THICKNESS MATERIAL GLASS TYPE DEPTH MATERIAL TYPE HEAD JAMB SILL

AH014A 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM A 06 15/A9.1 25/A9.1

AH021 1 3' - 0" 7' - 0" 1 3/4" WD B 5 3/4" HM A 03 15/A9.1 25/A9.1

AH022 1 3' - 0" 7' - 0" 1 3/4" WD B 5 3/4" HM A 03 15/A9.1 25/A9.1

AH023 1 3' - 0" 7' - 0" 1 3/4" WD B 5 3/4" HM A 02 15/A9.1 25/A9.1 KEY ACCESS CONTROL

AH028 1 3' - 0" 7' - 0" 1 3/4" WD B 5 3/4" HM A 03 15/A9.1 25/A9.1

AH037A 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM A 05 15/A9.1 25/A9.1

AI001 1 3' - 0" 7' - 0" 1 3/4" HM A 5 3/4" HM A 01 15/A9.1 25/A9.1 REMOTE ACCESS CONTROL AND CARDREADER

AI001A 1 3' - 0" 7' - 10" 1 3/4" Glass C 4 1/2" ALUM W5 04

AI002 1 3' - 0" 7' - 0" 1 3/4" HM EXIST 5 3/4" HM EXIST EX-01 EXIST EXIST EXISTING DOOR AND FRAME TO REMAIN.PROVIDE CARD READER ACCESS

AI003 1 3' - 0" 7' - 0" 1 3/4" HM EXIST 5 3/4" HM EXIST EX-01 EXIST EXIST EXISTING DOOR AND FRAME TO REMAIN.PROVIDE CARD READER ACCESS

SCALE: 1/4" = 1'-0"

DOOR TYPESSCALE: 1/4" = 1'-0"

INTERIOR FRAME ELEVATIONS

SCALE: 3" = 1'-0"A9.1

15 DOOR HEAD DETAIL

SCALE: 3" = 1'-0"A9.1

25 DOOR JAMB DETAIL

SCALE: 1/8" = 1'-0"

WINDOW TYPES

SCALE: 12" = 1'-0"

HARDWARE SETS

Page 11: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

2' -

6"

BULLET RESISTANT THRU-WALL TRANSACTION DRAWER

LEVEL 3 BULLET RESISTANT FIBERGLASS PANEL, UL752

5/8" TYPE "X" GYPSUM BOARD EA. SIDEOF METAL STUD FRAMING

METAL TRACK

BOX FRAME AROUND PERIMETER

RECEPTIONLOBBY

HOLLLOW METAL FRAME -GROUT SOLID - REFER TO WINDOW SCHEDULE AND ELEVATIONS

1 1/4" x 1 1/4" x 1/8" STEEL ANGLE METAL STOP

BULLET RESISTANT SPEAK THRU

T.O. COUNTER

2'-10"

RECEPTIONLOBBY

STAINLESS STEELCOUNTER

16" WIDE INTEGERAL 16 GA. STAINLESS STEEL DIP TRAY

GLAZING - REFER TO WINDOW SCHEDULE

2"

1' - 3" 2' - 1"

CONTINUOUS 1/4" BENT STEEL ANGLE EACH SIDE

2X NAILER WITH ANCHORS AT 2'-0" O.C.

FILE CASEWORK BY OWNER

WINDOW R.O.

7'-0"

STAINLESS STEEL BENT METAL BRACKET FULL WIDTH OF OPENING

BENT RETURNS AT PERMITER OF COUNTERTOP

BULLET-RESISTANTPANEL, RE: SPECS

WALL TYPE PER PLANS

6"

CONCRETE PAVINGAT APRON, SLOPE TODRAIN AWAY FROM BLDG

EXPANSION MAT'LAND SEALANT

ARCHITECTURAL BOLLARD, RE: SPECS

4' -

0"

1' - 6"

1' - 6" DIA CONCRETEFOOTING

SLOPED CONCRETEBASE

CORNER MULLION

ALUMINUM STOREFRONT SYSTEM

90.00°

4 1/2"

4 1/

2"

CLEAR TEMPERED GLAZING

TEMPERED GLAZING WITH TRANSLUCENT FILM

NOTE:

1. TOP OF CABINET TO BE 5'-0" A.F.F. VERIFY ROUGH OPENING DIMENSION WITH CABINET MFR. - TOP OF RO @ 4'-8" A.F.F.

2. VERIFY DIMENSIONS AND WALL SUPPORT REQUIREMENTS WITH CABINET MFR.3. PROVIDE FIRE RATED CABINET ASSEMBLY AT FIRE RATED WALL LOCATIONS.4. PROVIDE ACCESSIBLE TYPE HARDWARE MOUNTED @ 48" H. MAX. TO HANDLE5. FIRE EXTINGUISHER HANDLE 48" A.F.F. MAX.6. VERIFY FIRE EXTINGUISHER CABINET IS APPROPRIATE SIZE FOR WALL DEPTH.

RE: PLANS FOR WALL TYPE

GWB/METAL STUD WALL -SEE PLANS FOR WALL TYPE

FIRE EXTINGUISHER CABINET AS SPECIFIED

AT GWB WALL

6"

6 1/

2"

2 1/

2"

R.O

.

4"

1' - 1"

10 1/2" R.O.

TEMPERED GLAZING WITH TRANSLUCENT FILM

ALUMINIUM STOREFRONTSYSTEM

WALLEXISTING

SHIM & CONTINUOUS SEALANT, BOTH SIDES TYP

2

1' - 8 3/4"

1' -

11

1/4

"

HATCHED AREA REPRESENTSEXISTING WALL CONSTRUCTION

NEW METAL LOCKERSAS SPECIFIED

S41S41

S42S41

S41

S41

S41

ALIGN NEW CONSTRUCTIONWITH EXISTING WALL

NEW METAL LOCKERSAS SPECIFIED

NEW METAL LOCKERSAS SPECIFIED

1' - 9 7/8"

1' -

0"

S41

S41

S41

S42

S41

S41

S41

S42

1' -

3 5

/8"

1' -

4"

1' - 2 3/4"

1' - 7 1/8"

NEW METAL LOCKERSAS SPECIFIED

NEW METAL LOCKERSAS SPECIFIED

NEW METAL LOCKERSAS SPECIFIED

2

E

VE

RIF

Y1

' - 3

1/2

"

HATCHED AREA REPRESENTSEXISTING WALL CONSTRUCTION

S41

S41NEW METAL LOCKERSAS SPECIFIED

1' - 9 7/8"

EXISTING WINDOW TO REMAIN

CONC SUBSTRATE

RF TO CPT

CPT

REDUCER STRIP

TILE

CONC SUBSTRATE

CPT TO CONC

CPT

REDUCER STRIP

CONC

A B

CONC SUBSTRATE

LVT/RF TO CONC

LVT/RF

REDUCER STRIP

CONC

CNOTE: FLOOR FINISH CHANGES SHALL OCCUR UNDER THE COMMUNICATING DOOR, UNO.

NOTE: FLOOR FINISH CHANGES SHALL OCCUR UNDER THE COMMUNICATING DOOR, UNO.

NOTE: FLOOR FINISH CHANGES SHALL OCCUR UNDER THE COMMUNICATING DOOR, UNO.

CPT TO CPTD

NOTE: FLOOR FINISH CHANGES SHALL OCCUR UNDER THE COMMUNICATING DOOR, UNO.

CARPET RUBBER TRANSITION STRIPCARPET

CARPET

4"

METAL LOCKER,RE: SPECIFICATIONS

MANUFACTURERS 4" BASE

EXISTING CONCRETE SLAB

WALL RTPE, RE: PLANS

METAL PEDESTALS

EXISTING CONCRETE SLAB

BENCH, RE: SPECS

1' -

5 1

/2"

1' - 3" RE: PLAN FOR BENCH LENGTH

+2'-6" AFF

+2'-10" AFF

OFFICE SIDE LOBBY SIDE

VERIFY 1' - 1"

4" 1' - 3"

PLAM COUNTER

BULLET RESISTANT SPEAK THRU

STAINLESS STEELCOUNTER

16" WIDE INTEGERAL 16 GA. STAINLESS STEEL DIP TRAY

CONTINUOUS 1/4" BENT STEEL ANGLE EACH SIDE

STAINLESS STEEL BENT METAL BRACKET FULL WIDTH OF OPENINGBENT RETURNS AT PERMITER OF COUNTERTOP

EXISTING WALL

HOLLLOW METAL FRAME -GROUT SOLID - REFER TO WINDOW SCHEDULE AND ELEVATIONS

1 1/4" x 1 1/4" x 1/8" STEEL ANGLE METAL STOP

GLAZING - REFER TO WINDOW SCHEDULE

WINDOW R.O.

7'-0"

2"

4

F

2"

S41

S41

HATCHED AREA REPRESENTSEXISTING WALL CONSTRUCTION

NEW METAL LOCKERSAS SPECIFIED

S41

S41

S41

S42

1' - 8 3/4"

1' -

4"

HATCHED AREA REPRESENTSEXISTING WALL CONSTRUCTION

NEW METAL LOCKERSAS SPECIFIED

3' -

0"

IN FIELD39'-9" VERIFY 2"

1' -

6"

1' -

6"

6'-0" MAX

1 1/2" DIATMETER HANDRAIL. PAINTEDGALVANIZED METAL

EXISTING WALL

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:2

5 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

GENERALBUILDINGDETAILS

A10.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

SCALE: 1 1/2" = 1'-0"A10.1

56 TRANSACTION DRAWER

SCALE: 3/4" = 1'-0"A10.1

46 TRANSACTION COUNTER SECTION

SCALE: 1/2" = 1'-0"A10.1

36 BOLLARD DETAIL

SCALE: 3" = 1'-0"A10.1

26 INTERIOR STOREFRONT CORNER MULLION

SCALE: 1 1/2" = 1'-0"A10.1

55 FIRE EXTINGUISHER CABINET

SCALE: 3" = 1'-0"A10.1

16 INTERIOR STOREFRONT JAMB

SCALE: 1 1/2" = 1'-0"A10.1

31 PLAN DETAILSCALE: 1 1/2" = 1'-0"A10.1

33 PLAN DETAIL

SCALE: 1 1/2" = 1'-0"A10.1

21 PLAN DETAIL

SCALE: 1 1/2" = 1'-0"A10.1

51 TYP. FLOOR TRANSITION DETAILS

SCALE: 1 1/2" = 1'-0"A10.1

15 LOCKER BASE DETAIL

SCALE: 1 1/2" = 1'-0"A10.1

25 BENCH DETAIL

SCALE: 3/4" = 1'-0"A10.1

45 TRANSACTION WINDOW COUNTER SECTION

SCALE: 1 1/2" = 1'-0"A10.1

13 PLAN DETAILSCALE: 1 1/2" = 1'-0"A10.1

14 PLAN DETAIL

SCALE: 1/2" = 1'-0"A10.1

41 EXTERIOR HANDRAIL ELEVATION

Page 12: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

VERIFY IN FIELD6' - 5 3/4"

14

A11.2

10.0510.09 10.09

22.01 22.01

4' -

0"

XH014A

TB-1

TL-1

SS-1

10.1110.11

NOTE:NO TILE BEHIND MIRROR. MIRROR TO SIT FLUSHAGAINST WALL.

4' -

0"

VERIFY IN FIELD4' - 6 1/2"

14

A11.2

TL-1

TB-1

PAINTEDGYPSUMBOARD

AI003

TC-1SS-1

22.03

10.09

22.01

10.11

NOTE:NO TILE BEHIND MIRROR. MIRROR TO SIT FLUSHAGAINST WALL.

4' -

0"

TL-1

TB-1

PAINTEDGYPSUMBOARD

SS-1

22.01

10.09

10.11

4' -

0"

TL-1

TB-1

PAINTEDGYPSUMBOARD

22.03

4' -

0"

TL-1

TB-1

PAINTEDGYPSUMBOARD

TC-1

4' -

0"

TL-1

TB-1

PAINTEDGYPSUMBOARD

TC-1

4' -

0"

TL-1

TB-1

PAINTEDGYPSUMBOARD

SS-1

22.01

10.09

10.11

4' -

0"

14

A11.2

AI002

10.09

22.03

22.02

22.01

TL-1

TB-1

PAINTEDGYPSUMBOARD

TC-1

10.09

NOTE:NO TILE BEHIND MIRROR. MIRROR TO SIT FLUSHAGAINST WALL.

4' -

0"

22.03

TL-1

TB-1

PAINTEDGYPSUMBOARD

6

4' -

2"

2' -

10

"

2' - 6"2' - 6"2' - 6"

AI001

LINE OF EXISTINGCEILING

2' -

6"

EQEQ

TRANSACTIONDRAWER

56

A10.1

46

A10.1

46

A10.1

EXISTING COLUMNS

4" RUBBER BASE

W1 W1

3' - 4" 2' - 4" 3' - 4"

2' -

10

"4

' - 2

"

2' -

6"

TRANSACTION DRAWER

RUBBERBASE

56

A10.1

W2 W2

45

A10.1

45

A10.1 2' -

6"

3' - 4" 2' - 4" 3' - 4"

TRANSACTIONDRAWER

PLAM-1COUNTER WITH SUPPORTBRACKETS

W2 W2

2' -

6"

PLAM-1 COUNTERWITH SUPPORTBRACKETS

2' - 1" 7' - 6"

4' -

0"

XH014

22.02

22.03

10.05TL-1

TB-1

PAINTEDGYPSUMBOARD

TC-1

PAINTEDGYPSUMBOARD

EXISTING SHOWERPANS TO REMAIN

4' -

0"

TILE IN SHOWERSTO BE FULL HEIGHT

22.0322.03

TL-1

TB-1

XH013

TC-1

TC-1

PAINTEDGYPSUM BOARD

EXISTING SHOWERPANS TO REMAIN

4' -

0"

VERIFY IN FIELD6' - 1"

14

A11.2

PAINTED GYPSUMBOARD

TL-1

SS-1

10.0510.09 10.09

22.01 22.01TB-1

10.1110.11

NOTE:NO TILE BEHIND MIRROR. MIRROR TO SIT FLUSHAGAINST WALL.

LEGEND NOTES

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:3

2 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

INTERIORELEVATIONS

A11.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

SCALE: 1/4" = 1'-0"A11.1

31 MALES H014 INTERIOR ELEVATION

SCALE: 1/4" = 1'-0"A11.1

11 WOMENS I003 ELEVATIONSCALE: 1/4" = 1'-0"A11.1

12 WOMENS I004 ELEVATIONSCALE: 1/4" = 1'-0"A11.1

13 WOMENS I003 ELEVATIONSCALE: 1/4" = 1'-0"A11.1

14 WOMENS I003 ELEVATION

SCALE: 1/4" = 1'-0"A11.1

21 MENS I002 ELEVATIONSCALE: 1/4" = 1'-0"A11.1

22 MENS I002 ELEVATIONSCALE: 1/4" = 1'-0"A11.1

23 MENS I002 ELEVATIONSCALE: 1/4" = 1'-0"A11.1

24 MENS I002 ELEVATION

SCALE: 1/4" = 1'-0"A11.1

51 LOBBY I100A INTERIOR ELEVATIONSCALE: 1/4" = 1'-0"A11.1

52 LOBBY I100A INTERIOR ELEVATIONSCALE: 1/4" = 1'-0"A11.1

53 INTAKE I037 INTERIOR ELEVATIONSCALE: 1/4" = 1'-0"A11.1

54 INTAKE I037 INTERIOR ELEVATION

SCALE: 1/4" = 1'-0"A11.1

32 MALES H014 INTERIOR ELEVATIONSCALE: 1/4" = 1'-0"A11.1

34 MALES H014 INTERIOR ELEVATIONSCALE: 1/4" = 1'-0"A11.1

35 MALES H014 INTERIOR ELEVATION

10.05 NEW LOCKERS WITH SLANTED TOP AND COVERED BASE,VERIFY NUMBERING SEQUENCE WITH OWNER, TYPICAL

10.09 24"X36" MIRROR

10.11 SURFACE MOUNTED SOAP DISPENSER

22.01 NEW SINK, CONNECT TO EXISTING DOMESTIC WATER,WASTE AND VENT PIPING

22.02 NEW URINAL, CONNECT TO EXITING DOMESTIC WATER,WASTE AND VENT PIPING

22.03 NEW WATER CLOSET, CONNECT TO EXISTING DOMESTICWATER, WASTE AND VENT PIPING

Page 13: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

A. PROVIDE SEALANT AT ALL PERIMETER JOINTS WHERE COUNTERTOPS, BACK AND SIDE SPLASHES, CASEWORK AND MILLWORK ABUT WALLS.

CASEWORK AND MILLWORK GENERAL NOTES

EXISTING WALL

1/2" SOLID SURFACE COUNTER OVER 3/4" MARINE GRADE PLYWD SUBSTRATE (TYP)

UNDERMOUNT SINK- SEE PLUMBING

FAUCET- SEE PLUMBING

RACKS MADE TO ORDER EHV-VANITY SUPPORTS WITH PLAM REMOVABLE ACCESS PANEL, ATTACH TO FURRING STRIPS, WHERE OCCURS

MIRROR

WALL TILE AS SCHED.

1' -

1"

1' -

4"

5"

7"

WALL TILE AS SCHED.(TO UNDERSIDE OF COUNTERTOP)

9"

8" MIN

2' -

3"

7" MAX 6" MAX 11" MIN

1' - 5" MIN

MA

X A

FF

2' -

10"

STEEL ANGLE

RACKS COUNTER SUPPORT BRACKET, FLUSH MOUNT INSTALLATION

BLOCKING AS REQUIRED

WALL TYPE PER PLAN

2"x2" EDGE NAILER

1 1/2" x 1 1/2" STEEL ANGLE 24" VERTICAL LEG 18" HORIZONTAL LEG FASTEN TO METAL STUDS @ 16" O.C.

FASTEN WITH #10 SCREW @ 6" O.C.

COUNTERTOP, SEE ELEVATIONS FOR FINISH MATERIAL

SE

E E

LE

VA

TIO

NS

WALL FINISH, PER SCHEDULE

SEE PLAN

RESILIENT BASE

4"

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:3

3 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

INTERIORELEVATIONS

A11.2

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

SCALE: 1" = 1'-0"A11.2

14 COUNTER LAV DETAIL- SOLID SURFACESCALE: 1" = 1'-0"A11.2

15 TYP. WALL MOUNTED COUNTER

Page 14: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

A. ROOM FINISH SCHEDULE GENERAL NOTES APPLY TO ALL ROOM FINISH SCHEDULE SHEETS.

B. SEE SPECIFICATION FOR PAINTING OF ITEMS NOT NOTED IN THE ROOM FINISH SCHEDULE.

C. ALL GYPSUM WALLBOARD BULKHEADS SHALL BE PAINTED P-1 UNLESS NOTED OTHERWISE.

D. SEE REFLECTED CEILING PLANS FOR CEILING MATERIAL AND HEIGHT.

E. CEILING HEIGHTS, AS NOTED ON THE REFLECTED CEILING PLANS, ARE MEASURED FROM FINISH FLOOR OF SCHEDULED ROOM. FIELD VERIFY EXISTING HEIGHTS AND MATCH EXISTING

F. CONTRACTOR SHALL FURNISH AND INSTALL WALL BASE AROUND CASEWORK AND MILLWORK.

G. WHERE FLOOR FINISH CHANGES FROM ONE ROOM TO ANOTHER, SET JOINT OF THE MATERIALS AT THE CENTER OF THE COMMUNICATING DOOR.

ROOM FINISH SCHEDULEGENERAL NOTES

FLOOR NOTES:

1. SEE SHEET A13.1 FOR FLOOR PATTERN.2. SEE SHEET A13.1 FOR CERAMIC TILE FLOOR PATTERN.3. THIN-SET CERAMIC TILE FLOORS.

WALL NOTES:

1. SEE SHEET A11.1 FOR CERAMIC TILE WALL ELEVATIONS.2. CERAMIC TILE WAINSCOT TO 4'-0" ABOVE FINISH FLOOR.

CEILING NOTES:

1. SEE REFLECTED CEILING PLANS FOR CEILING ACCENT PAINT COLORS AND LOCATIONS

ROOM FINISH SCHEDULESPECIFIC NOTES

FFF

WW

C

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:3

3 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

INTERIORSCHEDULES

A13.0

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

FINISH SCHEDULE - CFCI

MaterialNumber DESCRIPTION MANUFACTURER PRODUCT SIZE COLOR/FINISH NOTES

09 30 00 Tiling

CT-1 Floor Tile DALTILE 12" X 12" TBD

TB-1 Cove Tile Base DALTILE 4" X 12" TBD

TL-1 Wall Tile DALTILE 6" X 6" TBD

TL-2 Wall Tile DALTILE TBD

066400 CUSTOM CASEWORK

PLAM-1 PLASTIC LAMINATE

088000 GLAZING

GF-1 GLAZING FILM 3M

GL-1 BULLET RESISTANT GLAZING

GL-2 GLAZING CLEAR TEMPERED

095100 ACOUSTIC CEILING TILE

APC-1 STANDARD CEILING PANEL

096500 RESILIENT FLOORING

RB-1 RESILIENT BASE JOHNSONITE 4" MATCH EXISTING

RF-1 RESILIENT FLOORING - FIELD ARMSTRONG VINYL COMPOSITION TILE 12" X 12" TBD

RF-2 RESILIENT FLOORING - ACCENT ARMSTRONG VINYL COMPOSITION TILE 12" X 12" TBD

RF-3 RESILIENT FLOORING - LOGO ARMSTRONG VINYL COMPOSITION TILE 12" X 12" TBD

096800 CARPET

CPT-1 CARPET TANDUS TBD 24" X 24"

CPT-2 CARPET TANDUS TBD 24" X 24"

WOC-1 WALK-OFF CARPET TANDUS TBD 24" X 24"

099000 PAINTING

PT-1 FIELD PAINT SHERWIN WILLIAMS LOW VOC, PREMIUM PAINT COLOR TBD; FLAT FINISH

PT-2 ACCENT PAINT SHERWIN WILLIAMS LOW VOC, PREMIUM PAINT COLOR TBD; FLAT FINISH

102100 TOILET COMPARTMENTS

TC-1 TOILET COMPARTMENT ASI SOLID PHENOLIC COLOR TBD ANCHORED/OVERHEAD BRACED

123661 SOLID SURFACING

SS-1 SOLID SURFACE TBD COLOR TBD

_ROOM FINISH SCHEDULE_

ROOM

FLOOR FINISH BASE FINISH MATERIAL

WALL

COMMENTSNUMBER NAME NORTH EAST SOUTH WEST

H013 FEMALES CT-1 TL-1

H013A FEMALE LOCKER RM CPT-1 RB-1

H014 MALES CT-1 TL-1

H014A MALE LOCKER RM CPT-1 RB-1

H037 VESTIBULE CPT-1 RB-1

H037A COMMAND STAFF LKR RM CPT-1 RB-1

I002 MENS CT-1 TL-1

I003 WOMENS CT-1 TL-1

Page 15: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

INTERIOR FINISH PLANGENERAL NOTES

A. INTERIOR FINISH PLAN GENERAL NOTES APPLY TO ALL INTERIOR FINISH PLAN SHEETS.

B. NOT ALL FLOOR AND WALL FINISHES ARE NOTED ON THE INTERIOR FINISH PLANS. SEE ROOM FINISH SCHEDULE FOR FLOOR AND WALL FINISHES NOT NOTED.

C. FLOOR PATTERN DIMENSIONS AND LOCATIONS ARE APPROXIMATE. MINOR ADJUSTMENTS MAY BE MADE FOR LAYOUT AND TO MINIMIZE WASTE AS LONG AS THE DESIGN INTENT IS MAINTAINED.

D. FOR FLOOR TILE PRODUCTS, ADJUST LAYOUT AS NECESSARY TO AVOID USING CUT WIDTHS THAT EQUAL LESS THEN ONE-HALF OF A TILE AT ROOM PERIMETER.

2 3 4 5 6 7 8 9 10

9.48.9

G

H

I

J

J.5

1.5

D

E

F

3' -

4"

PT-1

RB-1

CPT-1

COMMAND STAFF LKR RM

H037A

PT-1

RB-1

CPT-1

FEMALE LOCKER RM

H013A

PT-1

TL-1

CT-1

FEMALES

H013

09.0609.06

09.0609.0609.0609.06

CT

CP

T

CT

CP

T

PT-1

RB-1

CPT-1

MALE LOCKER RM

H014A

PT-1

RB-1

CPT-1

VESTIBULE

H037

PT-1

TL-1

CT-1

MALES

H014

TL-1/PT-1

TL-1

CT-1

WOMENS

I003

TL-1/PT-1

TL-1

CT-1

MENS

I002

PT-1

RB-1

EXIST

LOBBY

I000A

-

-

EXIST

VESTIBULE

I000

PT-1

RB-1

RF-1,2,3

LOBBY

I001

RF-3

8'-0" DIA. FLOOR LOGO

EQ EQ

09.05

09.06

09.06

09.06

09.06

LEGEND NOTES

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

8:3

8 P

M

BIM

360

://3

7-2

011

1-0

1 C

rim

inal Ju

stice

Ce

nte

r/37

-20

111

-01

_C

rim

ina

lJusticeC

ente

r_A

R_

20

20

.rvt

37-20111-01

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

INTERIOR FINISHPLAN

A13.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

SCALE: 1/8" = 1'-0"A13.1

2 FIRST FLOOR FINISH PLAN

WALL

BASE

FLOOR

09.05 NEW EL PASO COUNTY INSIGNIA - 8'-0" DIA

09.06 NEW TILE FLOORING, RE: FINISH PLAN AND SCHEDULE

Page 16: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

S D

SYMBOL

DOUBLE SINGLEABBR DESCRIPTION

RETURN DUCT UP

SUPPLY DUCT UP

OUTSIDE AIR DUCT UP

EXHAUST DUCT UP

RETURN DUCT DN

ROUND DUCT UP

ROUND DUCT DN

ROUND DUCT RISE

ROUND DUCT DROP

RADIUS ELBOW DUCT RISE

CAPPED DUCT

FIRE SMOKE DAMPER

FIRE DAMPER

SMOKE DAMPER

MOTORIZED DAMPER

RA

SA

OA

EA

RA

FSD

FD

SD

MD

SA

OA

EA

SUPPLY DUCT DN

OUTSIDE AIR DUCT DN

EXHAUST DUCT DN

ABBR DESCRIPTION ABBR DESCRIPTION ABBR DESCRIPTION

RADIUS ELBOW DUCT DROP

MITRED ELBOW DUCT RISE

MITRED ELBOW DUCT DROP

MITRED ELBOW

VANED ELBOW

RADIUS ELBOW

RECT.-TO-ROUND DUCT TRANSITION

DUCT TRANSITION

MANUAL VOLUME DAMPER W/ LOCKING

QUADRANT

MVD

CONICAL SPIN-IN FITTING W/ MANUAL VOLUME DAMPER

CONICAL TAP

FLEXIBLE DUCT CONNECTOR

FC

LOW PRESSURE FLEXIBLE DUCT

HVAC:

SYMBOL

SUPPLY DIFFUSER4-WAY THROW

SUPPLY DIFFUSER3-WAY THROW

SUPPLY DIFFUSER2-WAY THROW

SUPPLY DIFFUSER1-WAY THROW

RETURN AIR GRILLE

EXHAUST AIR GRILLE

CEILING ACCESS PANEL

AP

AIR TERMINALS:

MECHANICAL LEGEND

PIPING: SUPPLY PIPING (TYPE ABBR. AND

DESCR. NEXT COLUMN)

CHILLED WATER SUPPLY

CHWS

CHILLED WATER RETURN

CHWR

CONDENSER WATER SUPPLY

CWS

CONDENSER WATER RETURN

CWR

PROCESS COOLING WATER SUPPLY

PCS

PROCESS COOLING WATER RETURN

PCR

SYMBOL

RSREFRIGERANT

SUCTION

RLREFRIGERANT

LIQUID

RLREFRIGERANT

LIQUID

VALVES:

GV GATE VALVE

CV CHECK VALVE

PRVPRESSURE

REDUCING VALVE

SV SOLENOID VALVE

BLV BALANCING VALVE

GLVGLOBE VALVE

(STRAIGHT PATTERN)

BFV BUTTERFLY VALVE

BV BALL VALVE

PV PLUG VALVE

DVHOSE END DRAIN

VALVE

TCVAUTOMATIC TEMP. CONTROL VALVE,

2-WAY

GLVGLOBE VALVE

(ANGLE PATTERN)

TCVAUTOMATIC TEMP. CONTROL VALVE,

3-WAY

TPRTEMPERATURE/

PRESSURE RELIEF VALVE

STRSTRAINER W/

BLOW-OFF VAVLVE & CAPPED HOSE

END

FV FLOW VENTURI

SYMBOL

SYMBOLS:AIR TERMINAL

CALLOUT, TYP (X) DEVICES

1i

-

1i

-

MECHANICAL EQUIPMENT TAG

(POWERED)

MECHANICAL EQUIPMENT TAG (NON-POWERED)

RETURN/EXHAUST AIR FLOW SYMBOL

SUPPLY AIR FLOW SYMBOL

1

A101

SIMSECTION MARKER

SHEET KEY NOTE

T

TS

H

PS

CD

CO

THERMOSTAT

SPACE TEMPERATURE

SENSOR

HUMIDISTAT

SPACE PRESSURE SENSOR

CARBON DIOXIDE SENSOR

CARBON MONOXIDE SENSOR

DUCT MOUNTED SMOKE DETECTOR

SD SUCTION DIFFUSER

GLOW PRESSURE GAS(0.5 PSI OR

LESS)

MGMEDIUM PRESSURE GAS (0.5 TO 2 PSI)

LVG LEAVING

MA MAKE-UP AIR

MAX MAXIMUM

MCA MINIMUM CIRCUIT AMPACITY

MBH THOUSAND BTUH

MCC MOTOR CONTROL CENTER

MIN MINIMUM

MOCP MAX OVER CURRENT PROTECTION

MTL METAL

NC NOISE CRITERIA

(N) NEW

NTS NOT TO SCALE

OA OUTSIDE AIR

O.C. ON CENTER

OPNG OPENING

P PUMP

PD PRESSURE DROP/ DIFFERENTIAL

PF PRE-FILTER

PRESS PRESSURE

PSIG POUNDS PER SQUARE INCH GAUGE

PWL SOUND POWER LEVEL

QTY QUANTITY

RA RETURN AIR

(R) RELOCATE

REF REFERENCE

RF RETURN FAN

RH RELATIVE HUMIDITY

RLA RUNNING LOAD AMPS

RPM REVOLUTION PER MIN.

RQD REQUIRED

SA SUPPLY AIR

SCFM STANDARD AIR CUBIC FEET PER MINUTE

SF SUPPLY FAN

SHT SHEET

SPECS SPECIFICATIONS

SP STATIC PRESSURE

SQ SQUARE

SQFT SQUARE FOOT

SS STAINLESS STEEL

ST SOUND TRAP

TG TRANSFER GRILLE

TOD TOP OF DUCT

TSP TOTAL STATIC PRESSURE

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

UTR UP THRU ROOF

VAV VARIABLE AIR VOLUME

VEL VELOCITY

VFD VARIABLE FREQUENCY DRIVE

VSD VARIABLE SPEED DRIVE

VTR VENT THRU ROOF

WB WET-BULB

WF WATER FILTRATION

W/ WITH

W/0 WITHOUT

ABBREVIATIONS:

ABBR DESCRIPTION

FITTINGS:

CR CONCENTRIC REDUCER

ERECCENTRIC REDUCER

P&TPRESSURE/

TEMPERATURE PORT TAPS

U UNION

EJ EXPANSION JOINT

FC FLEXIBLE PIPE CONNECTOR

AC ALIGNMENT GUIDE

AN PIPE ANCHOR

FS FS FLOW SWITCH

PS PS PRESSURE SWITCH

PGPRESSURE GAUGE W/ GAUGE COCK

STEAM TRAP

ELBOW UP

ELBOW DN

TEE UP

TEE DN

ABBR DESCRIPTION

(NOT ALL SYMBOLS LISTED BELOW ARE USED IN THIS SET OF MECHANICAL DRAWINGS)

A101

1SIM

DIAGRAM CALLOUT

HEATING WATER SUPPLY

HWS

HEATING WATER RETURN

HWR

HIGH TEMP. HOT WATER SUPPLY

HTWS

HIGH TEMP. HOT WATER RETURN

HTWR

LOW PRESSURE STEAM SUPPLY

LPS

MEDIUM PRESSURE STEAM SUPPLY

MPS

HIGH PRESSURE STEAM SUPPLY

HPS

LOW PRESSURE STEAM CONDENSATE

RETURN

LPR

MPR

HPR

MEDIUM PRESSURE STEAM CONDENSATE

RETURN

HIGH PRESSURE STEAM CONDENSATE

RETURN

PRPUMPED

CONDENSATE RETURN

SCW SOFT COLD WATER

ACONTROL AIR (PNEUMATIC)

BD BOILER BLOW DOWN

BF BOILER FEED

BO BLOW OFF

CF CHEMICAL FEED

DR EQUIPMENT DRAIN

D INDIRECT DRAIN

PIPING:

RETURN PIPING (TYPE ABBR. AND

DESCR. NEXT COLUMN)

1

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

4:0

6:2

8 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

MECHANICALLEGEND

M0.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

07/15/2020

Page 17: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

4:0

6:2

8 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

MECHANICALSPECIFICATIONS

M0.2

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

BASIC MECHANICAL REQUIREMENTS

1. CONDITIONS1.1. UNLESS OTHERWISE NOTED, THE WORK DESCRIBED ON THE PLANS AND SPECIFICATIONS SHALL INCLUDE THE FURNISHING AND INSTALLATION OF ALL LABOR AND MATERIALS NECESSARY FOR COMPLETE AND OPERATIONAL

HVAC PLUMBING SYSTEMS. CONTRACTOR SHALL FURNISH THESE EVEN IF ITEMS REQUIRED TO ACHIEVE THIS (I.E. OFFSETS, ISOLATION AND BALANCING DEVICES, MAINTENANCE CLEARANCES, ETC.) ARE NOT SPECIFICALLY SHOWN.

1.2. ALL CAPACITIES ARE SCHEDULED AT A JOBSITE ALTITUDE OF 6200 FT ABOVE SEA LEVEL2. CODES AND REGULATIONS

2.1. COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES, REGULATIONS AND ORDINANCES, AND THE LATEST APPLICABLE REQUIREMENTS OF THE 2015 INTERNATIONAL BUILDING, MECHANICAL AND ENERGY CONSERVATION CODES, INTERNATIONAL PLUMBING CODE, FUEL GAS, AND ENERGY CONSERVATION CODES, LATEST EDITIONS OF NFPA, PPRBD REGIONAL AMENDMENTS, AND REGULATIONS OF THE UTILITY COMPANY FURNISHING SERVICE AS INTERPRETED BY THE LOCAL INSPECTION AUTHORITY WHO SHALL HAVE FINAL JURISDICTION.

2.2. COMPLY ALSO WITH ALL OSHA REQUIREMENTS AND DIRECTIVES.3. DEFINITIONS

3.1. DEFINITIONS OF DIVISION 1 AND GENERAL CONDITIONS OF THIS SPECIFICATION ALSO APPLY TO DIVISIONS 21-23 CONTRACT.3.2. "PROCUREMENT REQUIREMENTS" CONSTITUTE THE SOLICITATION, INSTRUCTIONS FOR PROCUREMENT, AVAILABLE INFORMATION, AND PROCUREMENT FORMS AND SUPPLEMENTS.3.3. “CONTRACT DOCUMENTS” CONSTITUTE THE CONTRACTING REQUIREMENTS, SPECIFICATIONS, CONTRACT DRAWINGS, PRE-CONTRACT REVISIONS (ADDENDA), CLARIFICATIONS AND PROPOSALS, AND CONTRACT MODIFICATIONS

PREPARED BY ARCHITECT FOR CONTRACTOR'S BID OR CONTRACTOR'S NEGOTIATIONS WITH THE OWNER.3.4. "CONSTRUCTION DOCUMENTS" INCLUDE THE "PROCUREMENT REQUIREMENTS", "CONTRACT DOCUMENTS", AND ANY RESOURCE DRAWINGS.3.5. “CONSTRUCTION SUBMITTALS” AND SIMILAR TERMS FOR DIVISIONS 21-23 WORK REFER TO SHOP DRAWINGS, COORDINATION DRAWINGS, PRODUCT DATA, SAMPLES, QA/QC SUBMITTALS, INFORMATIONAL SUBMITTALS, AND

CONSTRUCTION PHOTOGRAPHS PREPARED BY THE CONTRACTOR THAT CONVEY INFORMATION ABOUT SYSTEMS, EQUIPMENT, MATERIALS, PRODUCTS, AND ADMINISTRATIVE MATTERS, AND ARE NOT CONSIDERED CONSTRUCTION DOCUMENTS.

3.6. “(N)” INDICATES “NEW” EQUIPMENT TO BE PROVIDED UNDER THIS CONTRACT.3.7. “(E)” INDICATES “EXISTING” EQUIPMENT ON SITE WHICH MAY OR MAY NOT NEED TO BE RELOCATED AS A PART OF THIS WORK.3.8. “(R)” INDICATES EXISTING EQUIPMENT TO BE RELOCATED AS PART OF THIS WORK.3.9. “FURNISH” MEANS TO “SUPPLY” AND USUALLY REFERS TO AN ITEM OF EQUIPMENT.3.10. “INSTALL” MEANS TO “SET IN PLACE, CONNECT AND PLACE IN FULL OPERATIONAL ORDER”.3.11. “PROVIDE” MEANS TO “FURNISH AND INSTALL”.3.12. “EQUIVALENT” MEANS “MEETS THE SPECIFICATIONS OF THE REFERENCE PRODUCT OR ITEM IN ALL SIGNIFICANT ASPECTS.” SIGNIFICANT ASPECTS SHALL BE AS DETERMINED BY THE ARCHITECT.3.13. “WORK BY OTHER(S) DIVISIONS”; “RE:_____ DIVISION”, AND SIMILAR EXPRESSIONS MEAN WORK TO BE PERFORMED UNDER THE CONTRACT DOCUMENTS, BUT NOT NECESSARILY UNDER THE DIVISION OR SECTION OF THE WORK ON

WHICH THE NOTE APPEARS. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO COORDINATE WORK OF THE CONTRACT BETWEEN HIS/HER SUPPLIERS, SUBCONTRACTORS AND EMPLOYEES. IF CLARIFICATION IS REQUIRED, CONSULT ARCHITECT BEFORE SUBMITTING BID.

3.14. BY INFERENCE, ANY REFERENCE TO A “CONTRACTOR” OR “SUB-CONTRACTOR” MEANS THE ENTITY WHICH HAS CONTRACTED WITH THE OWNER FOR THE WORK OF THE CONTRACT DOCUMENTS.3.15. “ENGINEER” MEANS THE DESIGN PROFESSIONAL FIRM WHICH HAS PREPARED THESE CONTRACT DOCUMENTS. ALL QUESTIONS, SUBMITTALS, ETC. OF THIS DIVISION SHALL BE ROUTED TO THE ARCHITECT THROUGH PROPER

CONTRACTUAL CHANNELS.4. DRAWINGS AND SPECIFICATIONS

4.1. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND SHALL NOT BE SCALED. THEY SHOW CERTAIN PHYSICAL RELATIONSHIPS WHICH MUST BE ESTABLISHED WITHIN THE DIVISIONS 21-23 WORK AND ITS INTERFACE WITH OTHER WORK. ESTABLISHING THIS RELATIONSHIP IN THE FIELD IS THE EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR. THIS DIVISION SHALL COORDINATE ITS WORK WITH ALL DIVISIONS OF THE WORK AND ADJUST ITS WORK AS REQUIRED BY ACTUAL CONDITIONS OF THE PROJECT. 4.1.1. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING A BID TO BECOME THOROUGHLY FAMILIAR WITH THE ACTUAL CONDITIONS OF THE PROJECT.4.1.2. CERTAIN SYSTEMS REQUIRE ENGINEERING OF INSTALLATION DETAILS BY CONTRACTOR. UNLESS FULLY DETAILED IN THE CONTRACT DOCUMENTS, SUCH ENGINEERING IS THE EXCLUSIVE RESPONSIBILITY OF THE

CONTRACTOR.4.1.3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHERE CLEARANCES ARE LIMITED, AND WHERE INSTALLATION DRAWINGS OR SCHEMATICS, “CONSTRUCTION DRAWINGS”, OR COORDINATION DRAWINGS MAY BE

REQUIRED. THE CONTRACTOR SHALL PREPARE ALL SUCH COORDINATION DRAWINGS AS PART OF THE BASE CONTRACT. SUCH DRAWINGS MAY BE SUBMITTED TO THE ARCHITECT FOR RECORD AND COMMENT (AT THE CONTRACTOR'S OPTION).

4.2. REFER TO ARCHITECTURAL, STRUCTURAL, ELECTRICAL AND MECHANICAL DRAWINGS AND SPECIFICATIONS, AS A PART OF THIS SET, AND BE RESPONSIBLE FOR ALL INFORMATION CONTAINED THEREIN THAT AFFECTS MECHANICAL WORK.

4.3. LAY OUT ALL WORK IN ADVANCE. DO NOT DEFACE WORK OF OTHER TRADES. SLEEVES AND OPENINGS THROUGH THE ROOF TO BE BY THE BASE BUILDING ROOFING CONTRACTOR.5. PERMITS

5.1. SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, LICENSES, UTILITY COMPANY CHARGES AND INSPECTIONS IN CONNECTION WITH THE MECHANICAL WORK.6. COORDINATION

6.1. ORDER THE PROGRESS OF THE WORK TO CONFORM TO THE PROGRESS OF OTHER TRADES. COORDINATE ALL ELECTRICAL INSTALLATION AND ROUGH-IN AS REQUIRED.7. WORKMANSHIP

7.1. PROVIDE A COMPETENT FOREMAN ON THE JOB AT ALL TIMES. ACCOMPLISH ALL WORK IN A NEAT, WORKMANLIKE, FIRST-QUALITY MANNER COMPATIBLE WITH GOOD COMMERCIAL PRACTICES AND STANDARDS. PROVIDE COMPETENT WORKMEN.

8. SHOP DRAWINGS AND MATERIALS LIST8.1. SUBMIT COMPLETE MANUFACTURER'S SHOP DRAWINGS AND MATERIAL LISTS FOR APPROVAL OR AS REQUIRED IN DIVISION 1. PRIOR TO SUBMITTING THE SHOP DRAWINGS, REVIEW AND CERTIFY SAME AS TO COMPLIANCE WITH

THE PLANS AND SPECIFICATIONS AND FOR DIMENSIONAL SUITABILITY FOR THE APPLICATION. ALL PROPOSED DEVIATIONS FROM SPECIFICATIONS MUST BE CLEARLY LISTED UNDER A PROMINENT HEADING ENTITLED “DEVIATIONS”. INCLUDE ALL EQUIPMENT, DUCTWORK, VALVES, PIPING, CONTROLS AND APPURTENANCES. 8.1.1. IF PROJECT PERMITS ELECTRONIC SUBMITTALS, SUBMIT ONE (1) HARD COPY OF CONTROLS, INSTALLATION SHOP DRAWINGS, TEST-ADJUST-BALANCE REPORTS, AND FIRE PROTECTION DRAWINGSTO ENGINEER FOR

REVIEW IN ADDITION TO ELECTRONIC COPIES.8.2. PROVIDE MATERIAL AS SPECIFIED. SUBSTITUTIONS MAY BE CONSIDERED BEFORE THE CONTRACT DATE AS LONG AS DEDUCT ALTERNATE IS SUBMITTED AT BID TIME. SUBMIT SUBSTITUTIONS SEPARATELY FOR EACH PRODUCT

WITH SUPPORTING DATA, DRAWINGS AND SAMPLES AS APPROPRIATE, INCLUDING:8.2.1. ITEMIZED COMPARISON OF THE QUALITIES OF THE PROPOSED SUBSTITUTION WITH THAT SPECIFIED.8.2.2. CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK BECAUSE OF THE SUBSTITUTION.8.2.3. COST DATA COMPARING THE PROPOSED SUBSTITUTION WITH THE PRODUCT SPECIFIED.8.2.4. THE ARCHITECT WILL BE THE JUDGE OF THE ACCEPTABILITY OF THE PROPOSED SUBSTITUTION.8.2.5. ALL MATERIALS SHALL BE NEW AND BEAR THE UNDERWRITERS' LABORATORIES, INC. APPROVAL, PROVIDED A STANDARD HAS BEEN ESTABLISHED FOR THE MATERIAL.8.2.6. ALL EQUIPMENT SHALL MEET OR EXCEED MINIMUM REQUIREMENTS OF SMACNA AND ASHRAE.

9. INSTALLATION9.1. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH INFORMATION AS INDICATED ON THE DRAWINGS AND IN FULL ACCORD WITH MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS.

10. CUTTING AND PATCHING10.1. PROVIDE ALL CUTTING, CHANNELING, CHASING, DRILLING, ETC., OPERATIONS AS MAY BE REQUIRED FOR THE MECHANICAL WORK. IN GENERAL, ALL SUCH OPERATIONS SHALL BE HELD TO A MINIMUM.10.2. ALL PATCHING AND PAINTING SHALL BE DONE BY THE CONTRACTOR.

11. TEMPORARY CONSTRUCTION11.1. PROVIDE TEMPORARY HEAT AND WATER FOR CONSTRUCTION AS REQUIRED. USE OF EXISTING HEAT AND UTILITIES IS NOT ACCEPTABLE WITHOUT PRIOR WRITTEN PERMISSION OF THE ARCHITECT.

12. INTERRUPTION OF EXISTING SERVICES12.1. SHUTDOWN, WHEN NECESSARY, SHALL BE SCHEDULED TWO (2) WEEKS IN ADVANCE WITH THE OWNER AND PERFORMED DURING NON-WORKING HOURS (7:00PM - 6:00AM). INTERRUPTION SHALL BE ONLY AT OWNER APPROVED TIMES.

13. GUARANTEE13.1. GUARANTEE ALL MATERIALS, LABOR, WORKMANSHIP AND THE SUCCESSFUL OPERATION OF ALL EQUIPMENT INSTALLED UNDER THIS CONTRACT FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE AGAINST

DEFECTS AND FAULTY WORKMANSHIP.13.2. REPAIR OR REPLACE, AT NO EXPENSE TO THE OWNER, ALL DEFECTS WHICH MAY ARISE DURING THIS TIME DUE TO INFERIOR OR DEFECTIVE MATERIALS, EQUIPMENT OR WORKMANSHIP.

14. RECORD DRAWINGS14.1. MAINTAIN A COMPLETE SET OF MECHANICAL DRAWINGS AT THE JOB SITE WITH ALL CHANGES TO CONTRACT DOCUMENTS NEATLY MARKED THEREON IN A CONTRASTING COLOR. THIS SHALL BE A SEPARATE SET OF DRAWINGS

NOT USED FOR CONSTRUCTION PURPOSES, WHICH SHALL BE KEPT UP TO DATE AS THE JOB PROGRESSES AND SHALL BE MADE AVAILABLE FOR OBSERVATION BY THE ARCHITECT AT ALL TIMES. SUBMIT A COMPLETE RECORD SET OF DRAWINGS INCORPORATING ALL ADDENDUMS, BULLETINS AND INFORMATION REQUESTS TO THE ARCHITECT UPON COMPLETION OF THE PROJECT. PROVIDE ELECTRONIC CAD AND PDF FILES OF RECORD DRAWINGS ALONG WITH HARD COPY OF DRAWINGS.

15. DEMONSTRATION15.1. DEMONSTRATE THE OPERATION OF ALL SYSTEMS FOR THE OWNER AT A TIME AS DIRECTED BY THE ARCHITECT. PROVIDE TWO (2) HOURS OF INSTRUCTION.

16. MAINTENANCE MANUALS16.1. PRIOR TO COMPLETION OF PROJECT, SUBMIT FOUR (4) SETS OF OPERATION AND MAINTENANCE MANUALS IN THREE RING BINDERS.

17. EXISTING BUILDING17.1. THE CONTRACTOR'S ATTENTION IS CALLED TO THE FACT THAT THE EXISTING BUILDING WILL BE OCCUPIED BY THE OWNER DURING CONSTRUCTION. CONTINUED OPERATION OF THE FACILITY SHALL NOT BE HINDERED BY THIS

WORK. THE CONTRACTOR SHALL ACCOUNT FOR ALL ADDITIONAL COSTS WHICH MAY BE INCURRED BY HIM DUE TO THE DIFFICULTY OF WORKING OVER AND AROUND EMPLOYEES, DESKS, EQUIPMENT, ETC.; AND DUE TO THE HOURS OF THE DAY IN WHICH AN AREA MAY BE AVAILABLE WHEN SUBMITTING HIS BID.

17.2. CLEAN ALL SUPPLY, EXHAUST, TRANSFER AND RETURN AIR GRILLES BEING REUSED UNLESS OTHERWISE NOTED.17.3. VISUALLY INSPECT ALL EXISTING FIRE DAMPERS AND SMOKE/FIRE DAMPERS FOR PROPER POSITION AND ACCESS. REPLACE BROKEN LINKAGES AS REQUIRED. REPORT ANY ADDITIONAL DISCREPANCIES TO THE ARCHITECT

IMMEDIATELY.17.4. MATCH THE MATERIAL AND CONSTRUCTION METHODS OF ALL RELOCATED PIPE, DUCTWORK, CONDUITS, ETC. WHICH ARE TO BE RELOCATED WITH THAT OF THE ORIGINAL.17.5. DURING DEMOLITION OPERATIONS, ALL PERSONS AND PROPERTY SHALL BE PROTECTED. THE WORK SHALL PROCEED IN SUCH A MANNER SO AS TO MINIMIZE ANY SPREADING OF DUST, DEBRIS AND FLYING PARTICLES, AND SO

THAT ANY RELATED EFFECTS OF THE DEMOLITION DO NOT INTERFERE WITH SURROUNDING EQUIPMENT, PERSONNEL OR THE OPERATION OF THE BUILDING.17.6. MINIMIZE DISRUPTIONS TO MECHANICAL AND ELECTRICAL SYSTEMS IN OCCUPIED AREAS. COORDINATE ANY REQUIRED SYSTEM OUTAGES WITH THE ARCHITECT IN ADVANCE.

18. TENANT FINISH18.1. NO INCREASE ON CONTRACT SUM WILL BE ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING CONDITIONS. COORDINATE AND ADJUST ALL WORK BETWEEN TRADES AND EXISTING CONDITIONS IN ORDER TO ACCOMPLISH A

NEAT, INTEGRATED AND EFFICIENT INSTALLATION.18.2. EXAMINE THE CONTRACT DOCUMENTS OF ALL TRADES (E.G., THE ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL LIGHTING PLAN, FIRE PROTECTION PLAN, ETC.).18.3. COORDINATE NECESSARY EQUIPMENT, DUCTWORK AND PIPING LOCATIONS SO THAT THE FINAL INSTALLATION IS COMPATIBLE WITH THE MATERIALS AND EQUIPMENT OF THE OTHER TRADES.

19. ELECTRICAL COORDINATION19.1. VERIFY THE ELECTRICAL SERVICE PROVIDED BY THE ELECTRICAL CONTRACTOR BEFORE ORDERING ANY MECHANICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. INSTALLATION OR BID OF INCORRECT POWER OR

EQUIPMENT SHALL BE REMOVED AND REPLACED WITH CORRECT NEW AT NO INCREASE ON CONTRACT SUM.19.2. PROVIDE PREMIUM EFFICIENCY MOTORS WITH 1.15 SERVICE FACTOR ON ALL EQUIPMENT 1 HP AND OVER. MOTORS SHALL BE CAPABLE OF OPERATING CONTINUOUSLY AT 105OF UNDER JOBSITE CONDITIONS AND ALTITUDE.19.3. ALL MOTORS ½ HP OR SMALLER SHALL BE PROVIDED 1-PHASE. ALL OTHER MOTORS SHALL BE PROVIDED 3-PHASE UNLESS OTHERWISE NOTED.

BASIC MECHANICAL MATERIALS AND METHODS1. PRODUCTS

1.1. ACCESS PANELS.1.1.1. REFER TO ARCHITECTURAL DOCUMENTS FOR FINISHES AND PANEL TYPES.1.1.2. DOORS SHALL BE A MINIMUM OF 16 GAUGE STEEL, UNLESS REQUIRED OTHERWISE FOR FIRE RATING.1.1.3. PROVIDE WITH CONCEALED OR FLUSH MOUNT LATCHES.1.1.4. PROVIDE WITH FIRE RATING EQUIVALENT TO CONSTRUCTION WHICH INSTALLED.

1.2. FIRE-STOPPING MATERIALS.1.2.1. PRODUCTS TO BE USED SHALL HAVE BEEN TESTED IN ACCORDANCE WITH ASTM E 814-88, “AND UL 1479 TEST METHOD FOR THROUGH PENETRATIONS”, AND BE LISTED IN THE UL FIRE RESISTANCE DIRECTORY.1.2.2. PROVIDE FASTENERS, RESTRICTING COLLARS, BACKING MATERIALS, AND PROTECTIVE COATINGS AS REQUIRED TO COMPLY WITH THE UL SYSTEM LISTING

2. APPLICATION2.1. CUTTING AND PATCHING.

2.1.1. WHERE CUTTING AND PATCHING IS REQUIRED, ARCHITECTURAL REQUIREMENTS GOVERN.2.1.2. KEEP CUTTING TO A MINIMUM WHERE REQUIRED.2.1.3. PROVIDE PATCHING TO MATCH EXISTING AT A MINIMUM.2.1.4. DO NOT CUT OR DRILL THROUGH STRUCTURAL ITEMS WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT.

2.2. ACCESS PANELS 2.2.1. FURNISHED AND LOCATED BY DIVISIONS 21-23, INSTALLED BY TRADE RESPONSIBLE FOR SURFACE IN WHICH IT IS INSTALLED.2.2.2. COORDINATE EXACT LOCATION WITH ARCHITECT OR ARCHITECTURAL DRAWINGS.

2.3. FIRE-STOPPING2.3.1. INSTALL FIRESTOPPING MATERIALS IN ACCORDANCE WITH THEIR UL AND ASTM TESTED METHODS.2.3.2. INSTALL FIRE STOPPING AT ALL PENETRATIONS THROUGH FIRE-RATED CONSTRUCTION.

MECHANICAL IDENTIFICATION1. LABEL ALL NEW PIPING AND EQUIPMENT. 2. PROVIDE FULL BAND OR STRIP TYPE MARKERS AND FLOW ARROWS ON PIPING.3. PROVIDE ENGRAVED PLASTIC VALVE TAGS WITH VALVE NUMBER AND ATTACH WITH STANDARD CHAIN OR S-HOOKS. 4. PROVIDE LABELS ON CEILINGS UNDER CONCEALED DEVICES.5. LABEL EQUIPMENT AS TO THE AREA SERVED.6. PROVIDE LABEL COLORS TO COMPLY WITH ANSI A13.1.

PIPING AND EQUIPMENT INSULATION1. MANUFACTURERS

1.1. JOHNS-MANVILLE, ARMSTRONG, OWENS-CORNING, KNAUF.2. MATERIALS

2.1. SEAL ALL PIPING WHICH IS NORMALLY COLDER THAN AMBIENT WITH VAPOR BARRIER RATED MASTIC.2.2. TYPE A: FIBERGLASS PIPE INSULATION WITH SELF ADHESIVE ALL SERVICE VAPOR BARRIER JACKET. FITTINGS INSULATED WITH FIBERGLASS INSERTS IN PVC FITTING COVERS. ALL MATERIALS FLAME SPREAD 25, SMOKE

DEVELOPED 50.2.3. TYPE B: FLEXIBLE ELASTOMERIC CLOSED CELL PIPE INSULATION, FLAME SPREAD 25, SMOKE DEVELOPED 50.2.4. TYPE C: FLEXIBLE FIBERGLASS BLANKET WITH REINFORCED KRAFT/ALUMINUM FOIL VAPOR BARRIER FACING.2.5. TYPE D: SEMI-RIGID FIBERGLASS BOARD WITH REINFORCED VAPOR BARRIER FACING 3 LBS/CU. FT. DENSITY.2.6. TYPE E: FIBERGLASS BONDED TO FLEXIBLE ALL SURFACE JACKET. FIBERGLASS SLIT OR ORIENTED TO ALLOW CONFORMANCE TO ROUND SURFACES. DENSITY 3 LBS/CU. FT.

3. APPLICATION1.1. PIPING

1.1.5.1. ALL SIZES 1” THICK TYPE A OR B.1.1.6. ABOVE GROUND HEATING HOT WATER.1.1.6.1. 1-1/4” AND SMALLER- 1-½" THICK TYPE A INDOORS, 2” THICK TYPE A OUTDOORS.1.1.6.2. 1-1/2" AND LARGER 2” THICK INDOORS AND OUTDOORS THICK TYPE A.

DUCTWORK1. APPLICATION

1.1. FABRICATE IN ACCORDANCE WITH LATEST EDITION OF SMACNA STANDARDS AND INTERNATIONAL MECHANICAL CODE FOR LOW AND MEDIUM DUCTWORK PRESSURE.1.2. GALVANIZED STEEL, PITTSBURGH LOCK LONGITUDINAL SEAMS SEALED AIRTIGHT, DUCTMATE, OR T.D.C. SYSTEM.1.3. EXPOSED DUCT: SPIRAL GALVANIZED WITH “PAINTLOC” FINISH WHERE DUCT WILL BE PAINTED.1.4. CONCEALED DUCT: ROUND OR RECTANGULAR AS SHOWN ON DRAWINGS.1.5. DUCT TAPE NOT PERMITTED AS SEALANT.1.6. FIBERGLASS DUCT SYSTEMS NOT PERMITTED.1.7. DUCT DIMENSIONS ARE INSIDE CLEAR.1.8. DIFFUSER NECK SIZE IS SAME AS HARD DUCT SIZE, UNLESS NOTED OTHERWISE.1.9. UNLESS OTHERWISE NOTED, ALL CHANGES IN DIRECTION SHALL BE MADE WITH RADIUS ELBOWS WITH RADIUS TO CENTERLINE EQUAL TO 1.5 DUCT WIDTH.1.10. WHERE REQUIRED FOR SPACE CONSTRAINTS, PROVIDE SQUARE THROAT ELBOWS WITH SINGLE WIDTH TURNING VANES WITH TRAILING EDGE.1.11. FOR DUCT WIDTHS OF 36" OR LESS, PROVIDE MANUFACTURED SINGLE WIDTH TURNING VANES, WITH SPACING IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS FOR "STANDARD SPACING". USE DOUBLE

THICKNESS BLADES FOR DUCT WIDTHS GREATER THAN 36" AND INCREASE DUCT SIZE TO MAINTAIN FREE AREA. USE NO TRAILING EDGES.

2. DUCTWORK LINING2.1. JOHNS-MANVILLE PERMACOTE LINACOUSTIC, NCR OF 0.70 OR HIGHER BASED ON “TYPE A MOUNTING” AND TESTED IN ACCORDANCE WITH ASTM C423. EPA REGISTERED ANTI-MICROBIAL ACRYLIC COATED AGENT, FACTORY

APPLIED TO RESIST MICROBIAL GROWTH AS DETERMINED BY ASTM G21 AND G22.

DUCTWORK ACCESSORIES1. VOLUME DAMPERS SHALL COMPLY WITH SMACNA. DAMPER EACH BRANCH RUNOUT DUCT AND WHERE REQUIRED FOR ADEQUATE BALANCING. WHERE VOLUME DAMPERS ARE NOT READILY ACCESSIBLE, PROVIDE REMOTE OPERATOR.2. MISCELLANEOUS DUCTWORK ACCESSORIES.

2.1. DUCT ACCESS DOORS2.1.1. PROVIDE HINGED DUCT ACCESS DOORS WITH GASKETS, AND WITH INSULATION WHERE DUCTWORK IS INDICATED TO BE INSULATED.2.1.2. CESCO MODEL HAD-HINGED OR APPROVED EQUAL.

DUCT INSULATION1. MATERIALS:

1.1. FLEXIBLE FACED FIBERGLASS DUCTWORK INSULATION: JOHNS-MANVILLE MICROLITE, WITH FSK FACTORY APPLIED FOIL_SCRIM_KRAFT FACING.1.2. RIGID FIBERGLASS DUCTWORK INSULATION: JOHNS MANVILLE 800 SERIES, SPIN-GLAS TYPE 814, 3 LB. DENSITY RIGID BOARD WITH FSK JACKET.

1.2.1. FLEXIBLE PLAIN FIBERGLASS DUCTWORK INSULATION: JOHNS MANVILLE MICROLITE 1.0 LB/CU. FT. UNFACED.1.3. DUCTWORK INSULATION ACCESSORIES: PROVIDE STAPLES, BANDS, WIRES, TAPE, ANCHORS, CORNER ANGLES, AND SIMILAR ACCESSORIES AS RECOMMENDED BY THE INSULATION MANUFACTURER FOR THE APPLICATIONS

INDICATED.2. APPLICATION:

2.1. CONCEALED UNLINED SUPPLY DUCTWORK: 1-1/2" THICK FLEXIBLE FACED FIBERGLASS.2.2. EXPOSED UNLINED SUPPLY DUCTWORK IN CONDITIONED SPACE: NONE.2.3. CONCEALED UNLINED RETURN AIR DUCTWORK: 1-1/2" FLEXIBLE FIBERGLASS, WITH OR WITHOUT FACING.2.4. EXHAUST AIR DUCTWORK WITHIN 30 FEET OF OPENING TO EXTERIOR: 1-1/2" THICK FLEXIBLE FACED FIBERGLASS.

FANS

1. MANUFACTURERS1.1. GREENHECK, COOK, ACME, PENNBARRY.2. PRODUCTS

2.3. UPBLAST ROOF EXHAUSTERS.2.3.1. SPUN ALUMINUM HOUSING2.3.2. INTERNAL RUBBER VIBRATION ELIMINATORS2.3.3. BALL BEARINGS2.3.4. AIRFOIL FAN WHEEL2.3.5. FAN SHALL MEET ALL SOUND CRITERIA AS LISTED IN THE SCHEDULE.2.3.6. WIND TIE-DOWNS TO CURB.2.3.7. SEE SCHEDULE FOR CAPACITIES AND ACCESSORIES2.3.8. UL 762 LISTED FOR GREASE LADEN AIR WHERE NOTED, WITH DRAIN HOLES AND ACCESS DOORS

3. INSTALLATION3.1. INSTALL UNITS LEVEL AND PLUMB3.2. PROVIDE FLEXIBLE DUCT CONNECTIONS AT ALL FANS.3.3. SECURE FANS TO ROOF CURBS AT 12” O.C., MINIMUM 2 PER SIDE AND MAXIMUM 6” FROM CORNERS. PROVIDE WIND TIE-DOWNS TO CURB.3.4. PROVIDE RESILIENT GASKET BETWEEN FAN AND CURB.3.5. CHECK FAN FOR PROPER BALANCE TO ELIMINATE UNUSUAL NOISE OR VIBRATION.3.6. EXTEND DUCT FULL SIZE OF CURB OPENING TO TOP OF CURB WITH CONTINUOUS FLANGE OVER TOP OF CURB TO CREATE AN AIRTIGHT SEAL.

AIR INLETS AND OUTLETS1. MANUFACTURERS

1.1. PRICE, TITUS, KRUEGER, ACUTHERM THERMAFUSER.2. PRODUCTS

2.1. REFER TO DRAWINGS AND SCHEDULE FOR TYPE AND ACCESSORIES.2.2. SUBMIT CATALOG DATA.2.3. FOR MANUFACTURERS OTHER THAN NAME SCHEDULED, SUBMIT ALSO EACH OUTLET SHOWING NC, THROW AND PRESSURE DROP ALONG WITH ITEMIZED COMPARISON TO SPECIFIED OUTLET.2.4. PROVIDE PRODUCTS TESTED IN ACCORDANCE WITH AIR DIFFUSION COUNCIL TEST CODES AND BEARING THE ADC SEAL. SUBMIT SUPPORTING DATA THAT SHOWS OUTLETS WERE TESTED IN ADC CERTIFIED LAB.2.5. PROVIDE ALUMINUM IN ALL LOCKER/TOILET/SHOWER AND ADJACENT AREAS.

3. APPLICATION3.1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS.3.2. EXPOSED MOUNTING SCREWS:

3.2.1. USE TAMPER PROOF SCREWS IN COUNTERSUNK HOLES.3.2.2. PAINT SCREWS TO MATCH FRAME.

3.3. FIRE RATED CEILINGS:3.3.1. PROVIDE INSULATION EQUIVALENT TO CEILING CONSTRUCTION RATING ABOVE DIFFUSER BETWEEN CEILING OPENING AND CEILING DAMPER.3.3.2. PROVIDE RATED DAMPER IN EACH FIRE RATED CEILING WHERE SHOWN AND REQUIRED. COORDINATE WITH ARCHITECTURAL PLANS. NOT ALL DAMPERS ARE SHOWN OR NOTED ON DOCUMENTS.

3.4. CEILING AIR OUTLETS3.4.1. ALIGN IN CEILING WITH TILES OR ARCHITECTURAL FEATURES AND LOCATE SYMMETRICALLY.3.4.2. PROVIDE MINIMUM ONE DIAMETER STRAIGHT DUCT INLET AND FULL RADIUS BEND ON FLEXIBLE DUCT CONNECTION. WHERE CEILING SPACE IS INADEQUATE, PROVIDE INSULATED PLENUM WITH HEIGHT EQUAL TO TWO

NECK DIAMETERS AND SIDE INLET TAP NEAR TOP OF PLENUM.3.4.3. PROVIDE FRAMED OPENING IN HARD-LID CEILINGS SO CEILING AIR OUTLET MOUNTS ON THE FRAME AND IS REMOVABLE SIMILAR TO AN OUTLET IN A LAY-IN CEILING SYSTEM.3.4.4. RELOCATE DIFFUSERS WITHIN A 2 FOOT RADIUS WHERE CEILING PATTERN IS AT VARIANCE WITH OUTLET LOCATIONS SHOWN.

3.5. SIDEWALL AIR OUTLETS3.5.1. MOUNT AT HEIGHT AS SHOWN OR AS DIRECTED BY ARCHITECT.3.5.2. ARRANGE SO LOCATIONS ARE SYMMETRICAL TO AND CONGRUENT WITH ARCHITECTURAL FEATURES.

3.6. BALANCING3.6.1. DO NOT USE OPPOSED BLADE DAMPERS AT AIR OUTLETS FOR BALANCING. PROVIDE ALL BRANCH DUCTS WITH VOLUME DAMPERS. ONLY WHERE IT IS NOT POSSIBLE TO INSTALL DUCT DAMPERS PROVIDE OPPOSED BLADE

KEY-OPERATED DAMPERS DIRECTLY BEHIND THE AIR OUTLET. FURNISH TWO KEYS FOR EACH TYPE OF OPERATOR.

BUILDING MANAGEMENT AND AUTOMATIC TEMPERATURE CONTROL SYSTEMS

1. MANUFACTURERS1.1. MATCH EXISTING BUILDING SYSTEM.

2. APPLICATION2.1. EXISTING CONTROL AND SUPERVISION OF EQUIPMENT AND SPACES IS DDC. INTERFACE WITH BUILDING DDC SYSTEM. SUCCESSFUL CONTRACTOR SHALL PROVIDE ALL DEVICES REQUIRED FOR FULL AND FUNCTIONAL CONTROL

OF THE SYSTEMS PRESENTED IN THE CONSTRUCTION DOCUMENTS.2.2. PROVIDE TEMPERATURE SENSOR IN IT ROOM TO MONITOR AND ALARM AT DDC AND LOCAL AUDIO/VISUAL ALARM OUTSIDE THE ROOM TO INDIRECTLY VERIFY CRAC UNIT OPERATION.2.3. PROVIDE DDC CONNECTION TO NEW SUBZONE VAV DIFFUSER CONTROLLER TO MONITOR AND ALARM.2.4. RECALIBRATE AND CLEAN EXISTING THERMOSTATS BEING REUSED.2.5. LABEL ALL DEVICES INCLUDING THERMOSTATS. 2.6. UPDATE EXISTING DDC SYSTEM GRAPHICS.2.7. ALL DEVICES AND INSTALLATION SHALL BE WARRANTED TO BE FREE FROM DEFECTS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF JOB ACCEPTANCE BY THE OWNER. ANY EQUIPMENT, SOFTWARE, OR LABOR FOUND TO BE

DEFECTIVE DURING THIS PERIOD SHALL BE REPAIRED OR REPLACED WITHOUT EXPENSE TO THE OWNER. FACTORY AUTHORIZED WARRANTY SERVICE SHALL BE AVAILABLE WITHIN 75 MILES OF JOBSITE.3. SEQUENCE OF OPERATIONS

3.1. COMMISSION EXISTING TO VERIFY PROPER OPERATION.3.2. MAINTAIN SAME CONTROL SEQUENCE AS EXISTING IF OWNER SATISFIED WITH EXISTING.

TEST-ADJUST-BALANCE1. TEST- ADJUST- BALANCE OF ALL AIR SYSTEMS SHALL BE BY A NEBB, AABC OR TABB CERTIFIED INDEPENDENT CONTRACTOR OR TAB FIRM APPROVED BY THE ENGINEER, HIRED BY GENERAL CONTRACTOR. PROCEDURE IN ACCORDANCE

WITH ASSOCIATED AIR BALANCE COUNCIL (AABC), NEBB OR TABB.2. TAKE READINGS OF EXISTING SYSTEMS AFFECTED BY WORK PRIOR TO STARTING WORK TO DOCUMENT EXITING FLOWS. SUBMIT REPORT. 3. NOTIFY THE CONTRACTOR OF CONDITIONS DETRIMENTAL TO THE PROPER COMPLETION OF THE TEST-ADJUST-BALANCE WORK PRIOR TO THE START OF BALANCING. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS

HAVE BEEN CORRECTED.4. ADJUST AIRFLOWS TO WITHIN -5% TO +5% OF SCHEDULED VALUES AND OUTSIDE AIR AT THE UNIT 0% TO +5%.5. SUBMIT COMPLETE BALANCE REPORTS TO THE ARCHITECT AND TO THE BUILDING DEPARTMENT.6. SUBMIT APPROVED BALANCE REPORT TO INSPECTOR AT TIME OF FINAL INSPECTION.7. PATCH HOLES IN INSULATION AND DUCTWORK THAT HAVE BEEN DRILLED OR CUT FOR TEST PURPOSES IN A MANNER RECOMMENDED BY THE ORIGINAL INSTALLER.

07/15/2020

Page 18: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

SD

SD

SD

S DS D

S DS D

SD

SD

SD

SD

T T

T

T

T

SD

T

T

T

T

T

2 3 4 5 6 7 8 9

10

9.48.98.2

G

H

I

1.5

D

E

F

30"x

16"

SA

36"x14" RA

14"x

12"

SA

8"x8" EA

12"x10" EA

10"x

10"

EA

12"x

8"

SA

14"x12" SA 18"x12" SA

14"x

12"

SA

12"x

10"

SA

14"ø SA

28"x

16"

SA

20"x16" SA

24"x18" SA

20"x

8"

SA

14"ø SA 16"x14" SA

12"x

12"

SA

12"x

12"

SA

14"x

12"

SA

30"x12" SA 25"x10" SA

46"x

12"

RA

16"ø SA 14"ø SA

12"ø

SA

18"x16" SA

20"x8" SA

18"x

16"

SA

14"ø SA

20"x8" SA

22"x22" TA

8"ø

SA

9"ø

SA

8"x

10"

EA

10"x

10"

EA

16"ø

SA

14"x12" SA

22"x

16"

SA

10"E (4)

468

E465

E465

E335

E335

14"E

720

14"E

715

8"E

90

E180

E135

8"E

200

E180

E315

E400

E440

8"E

250

8"E

245

8"E

245

6"E

150

E150

E125

E50

E430

E430

E125

FEMALELOCKER RM

H013A

MALELOCKER RM

H014A

FEMALES

H013

MALES

H014

COMMANDSTAFF LKR RM

H037A

CORRIDOR

H000

1

EF

2

EF

N400

24"x24"

10"x10"EA

M3

M4

M1

M2

M5

M6

8"x8" SA

M7

M8

M9

M10

14"x14" EA

N590

24"x24"

N120

12"x12"

M11

M11

M11

PROVIDE FINAL TAB REPORT ON EXISTING IN THIS AREA INCLUDING RESTROOMS

M10 M10(E) AHU ON ROOFREBALANCE TO 11,465 CFM, 2,300 OA. MODIFY AHU CONTROLS TO ACCOMMODATE INCREASED OA DURING FAN TURNDOWN.

M12

14"x12"EA

M13

(E) RTU ON ROOFREBALANCE TO 1,872 CFM, 375 CFM OA.

16"ø SA

M9

M1

M14

M9

E (3)150

M15

PROVIDE FINAL TAB REPORT ON EXISTING IN THIS AREA INCLUDING RESTROOMS

(E)TRANSFER BOOT ABOVE CEILING INTO RETURN AIR PLENUM

12"x

12"

EA

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

4:0

6:2

8 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

MECHANICALFLOORPLAN

M1.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

1/8" = 1'-0"1 MECHANICAL PLAN

MECHANICAL GENERAL NOTES

1 FIELD VERIFY EXACT LOCATION AND CONDITIONOF ALL EQUIPMENT, DUCTWORK AND GRD'SPRIOR TO BEGINNING WORK.

2 SEAL ALL PENETRATIONS THROUGH RATEDWALLS TO MAINTAIN THE INTEGRITY OF THEWALL RATING.

3 CONTRACTOR SHALL RECORD EXISTINGAIRFLOWS FOR DIFFUSERS. GRILLES, ROOFTOPUNITS, FANS, AND VAV BOXES AFFECTED FORBASIS OF EXISTING CONDITIONS PRIOR TOSTARTING WORK. SUBMIT REPORT TOARCHITECT.

4 BALANCE ALL SYSTEMS AT COMPLETION OFPROJECT TO INDICATED FLOWS. PROVIDEARCHITECT & INSPECTION WITH REPORT.

5 RECALIBRATE REUSED THERMOSTATS.

6 MOUNT THERMOSTATS +48"AFF TO THE TOP ANDCOORDINATE LOCATION OF THERMOSTATS WITHLIGHT SWITCHES. ARRANGE IN ORDERLYFASHION.

7 CONTRACTOR SHALL NOTIFY ARCHITECT IN RFIFORM OF ANY DISCREPANCIES OR QUESTIONSPRIOR TO PROCEEDING WITH WORK.

8 CLEAN ALL GRD'S BEING REUSED ORRELOCATED WITHIN AREAS OF WORK.

9 ALL MATERIALS IN RETURN AIR PLENUMS SHALLHAVE A MINIMUM RATING OF 25 FLAME/ 50SMOKE.

10 OCCUPANCY AND SPACE TYPES IN OPENOCCUPIED AREA AND OTHER AREAS HAVE NOTCHANGED FROM EXISTING DESIGN, THEREFORE,NO CHANGE IN OUTSIDE AIR VENTILATION ISREQUIRED.

11 INSTALLATION SHALL CONFORM TO THEREQUIREMENTS OF THE INTERNATIONALMECHANICAL AND ENERGY CONSERVATIONCODES.

12 MATCH EXISTING MATERIALS FOR LIKE NEWWORK.

13 CAP REMOVED DUCTS AT CONNECTIONS TOEXISTING.

14 RELOCATE SPRINKLER HEADS AND SIZE PIPESPER NFPA 13. PROVIDE SYTLE HEAD ANDCOVERS TO MATCH EXISTING.

15 SUPPORT ALL EQUIPMENT INDEPENDENTLY. DONOT SUPPORT FROM PIPING.

16 USE CURRENT CODE FOR DUCT INSULATION

17 MAINTAIN 10 FT. MIN CLEARANCE FROMPARAPET WITH ROOF MOUNTED EQUIPMENT.

18 PROVIDE REMOTE OPERATORS RECESSEDBEHIND SOLID ESCUTCHEON PLATE ON ALLVOLUME DAMPERS ABOVE HARD LID CEILINGS.

19 REMOVE AND REPLACE CEILING AIR DEVICESAND LOCATE THEM TO MESH WITH NEWREFLECTED CEILING AS REQUIRED PERARCHITECTURAL DRAWINGS.

20 UPDATE DDC SYSTEM GRAPHICS ANDCONTROLS.

21 OWNER HAS FIRST RIGHT OF REFUSAL FORREMOVED ITEMS.

22 CONTRACTOR SHALL COORDINATE WORKBETWEEN ALL OTHER TRADES. REFER TO ARCH,STRUCT, ELEC AND PLBG DRAWINGS AND BERESPONSIBLE FOR ALL INFORMATIONCONTAINED THEREIN THAT AFFECTSMECHANICAL WORK.

KEY NOTES

M1 RELOCATE EXISTING THERMOSTAT TO NEWLOCATION.

M2 RELOCATE EXISTING SUPPLY AIR DIFFUSER TONEW LOCATION IN COMMAND STAFF LKR ROOMH037A.

M3 NEW ROOF MOUNTED EXHAUST FAN (EF-1)EQUAL TO GREENHECK CUE-090-VG, DIRECTDRIVE UPBLAST CENTRIFUGAL ROOF EXHAUST,400 CFM, 0.5 SP, 1725 RPM, 1/10 HP, 115V/1PH,12.5x12.5 ROOF OPENING, BACKDRAFT DAMPER,DISCONNECT SWITCH, BIRDSCREEN, WINDTIE-DOWNS, INSULATED ROOF CURB,INTERLOCK WITH HVAC UNIT WHICH SERVESSAME SYSTEM (VIA DDC SYSTEM), LABEL FANSAS TO AREAS SERVED. COORDINATE NEWROOF OPENING WITH STRUCTURAL ENGINEERAND REROOFING WITH ARCHITECT.

M4 NEW ROOF MOUNTED EXHAUST FAN (EF-2)EQUAL TO GREENHECK CUE-121-VG, DIRECTDRIVE UPBLAST CENTRIFUGAL ROOF EXHAUST,1300 CFM, 0.75 SP, 1725 RPM, 1/2 HP, 115V/1PH,14.5x14.5 ROOF OPENING, BACKDRAFT DAMPER,DISCONNECT SWITCH, BIRDSCREEN, WINDTIE-DOWNS, INSULATED ROOF CURB,INTERLOCK WITH HVAC UNIT WHICH SERVESSAME SYSTEM (VIA DDC SYSTEM), LABEL FANSAS TO AREAS SERVED. COORDINATE NEWROOF OPENING WITH STRUCTURAL ENGINEERAND REROOFING WITH ARCHITECT.

M5 RELOCATED SUPPLY AIR DIFFUSER.REBALANCE TO 90 CFM.

M6 RELOCATE EXISTING VAV BOX TO NEWLOCATION OUTSIDE COMMAND STAFF LKRROOM H037A. CAP EXISTING DUCT.

M7 RELOCATED EXISTING VAV BOX (VAV1H-2),PIPING AND VALVING. PROVIDE NEW 2 PIECEFULL PORT BALL VALVES AND PETE'S PLUGS ATCOIL. REFURBISH CONTROL VALVE. REBALANCETO 90 CFM.

M8 REMOVE EXISTING DUCTWORK ASSOCIATEDWITH VAV BOX AND SUPPLY AIR DIFFUSER. CAPDUCT AT MAIN.

M9 RELOCATED EXISTING THERMOSTAT.COORDINATE FINAL LOCATION WITH ARCHITECTPRIOR TO INSTALLATION.

M10 COORDINATE LOCATIONS OF EXISTING SUPPLYAIR DIFFUSER AND RETURN AIR GRILLES WITHNEW REFLECTED CEILING LAYOUT AND LIGHTS.REBALANCE DIFFUSERS TO CFM SHOWN ANDEXISTING ASSOCIATED ROOF TOP UNIT AND/ORVAV BOX.

M11 NEW EXHAUST REGISTER EQUAL TO PRICEPDDR, PERFORATED. COORDINATE WITHREFELECTED CEILING PLAN LIGHT LOCATIONSAND ALL FRAME STYLES WITH CEILING SYSTEMFURNISHED, REFER TO ARCHITECTURALDIVISION.

M12 VOLUME DAMPER. BALANCE TO REMAININGRETURN AIR FROM COMM ELEC ROOM.

M13 REMOVE EXISTING RETURN AIR GRILLE ANDRETURN TO OWNER. REPLACE WITH NEWEXHAUST REGISTER EQUAL TO PRICE PDDR,PERFORATED.

M14 EXISTING RETURN AIR GRILLE TO REMAIN.PROVIDE BACKDRAFT DAMPER IN A BOOT. AIRCAN ONLY GO IN ROOM, NOT BACK OUT INTOPLENUM.

M15 PROVIDE 20 SQ. FT. TRANSFER AIR OPENING INWALL ABOVE CEILING.

07/15/2020

Page 19: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

ABBR DESCRIPTIONABBR DESCRIPTION ABBR DESCRIPTIONSYMBOL

PLUMBING LEGEND

PIPING:

PIPING TO BE REMOVED

SYMBOL SYMBOL

SYMBOLS:PLUMBING FIXTURE

DESIGNATION

1i

-

1i

-

PLUMBING EQUIPMENT TAG

(POWERED)

PLUMBING EQUIPMENT TAG (NON-POWERED)

1

A101

SIM

SECTION MARKER

SHEET KEY NOTE

FITTINGS:

CR CONCENTRIC REDUCER

ERECCENTRIC REDUCER

P&TPRESSURE/

TEMPERATURE PORT TAPS

U UNION

EJ EXPANSION JOINT

FC FLEXIBLE PIPE CONNECTOR

AC ALIGNMENT GUIDE

AN PIPE ANCHOR

FS FS FLOW SWITCH

PS PS PRESSURE SWITCH

PGPRESSURE GAUGE W/ GAUGE COCK

STEAM TRAP

ELBOW UP

ELBOW DN

TEE UP

TEE DN

(NOT ALL SYMBOLS LISTED BELOW ARE USED IN THIS SET OF MECHANICAL DRAWINGS)

A101

1SIM

DIAGRAM CALLOUT

DOMESTIC COLD WATER

CW

DOMESTIC HOT WATER

HW

DOMESTIC HOT RECIRCULATING

WATER

HWC

SANITARY WASTE ABOVE FLOOR

SAN

SANITARY WASTE BELOW FLOORSBF

V

ST

SANITARY VENT

STORM PIPING

OD STORM OVERFLOOR PIPING

SCW SOFT COLD WATER

G LOW PRESSURE GAS (<= 0.5 PSI)

MG MEDIUM PRESSURE GAS (0.5 TO 2 PSI)

F FIRE

DR EQUIPMENT DRAIN

A COMPRESSED AIR

D INDIRECT DRAIN

EXISTING PIPING1i

(E)

POINT OF CONNECTION

INVERT ELEVATION

VALVES:

GV GATE VALVE

CV CHECK VALVE

PRVPRESSURE

REDUCING VALVE

SV SOLENOID VALVE

BLV BALANCING VALVE

GLVGLOBE VALVE

(STRAIGHT PATTERN)

BFV BUTTERFLY VALVE

BV BALL VALVE

PV PLUG VALVE

DVHOSE END DRAIN

VALVE

GLVGLOBE VALVE

(ANGLE PATTERN)

TPRTEMPERATURE/

PRESSURE RELIEF VALVE

STRSTRAINER W/

BLOW-OFF VAVLVE & CAPPED HOSE

END

FV FLOW VENTURI

WCO WALL CLEANOUT

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FS FLOOR SINK

HB

WH

HOSE BIBB

WALL HYDRANT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AP ACCESS PANEL

DIA DIAMETER

DN DOWN

DWG DRAWING

(E) EXISTING

FPM FEET PER MINUTE

FS FLOOR SINK

FT. WC.FEET WATER COLUMN

GAL GALLON

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

IN. WC. INCHES WATER COLUMN

ISOL. ISOLATOR

KW KILOWATTS

LBS POUNDS

LBS/HR POUNDS PER HOUR

MAX MAXIMUM

MIN MINIMUM

(N) NEW

NTS NOT TO SCALE

O.C. ON CENTER

OPNG OPENING

P PUMP

PD PRESSURE DROP/ DIFFERENTIAL

PRESS PRESSURE

PSIG POUNDS PER SQUARE INCH GAUGE

QTY QUANTITY

(R) RELOCATE

REF REFERENCE

RPM REVOLUTION PER MIN.

RQD REQUIRED

SHT SHEET

SPECS SPECIFICATIONS

SQFT SQUARE FOOT

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

VTR VENT THRU ROOF

W/ WITH

W/O WITHOUT

ABBREVIATIONS:

1

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

2:4

2:0

4 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

PLUMBINGLEGEND

P0.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

07/15/20

Page 20: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

PLUMBING PIPE MATERIALS SCHEDULE

NOTES

SERVICE

WASTE & VENT ABOVE GROUND

DOMESTIC WATER ABOVE GROUND

1. REFER TO SPECIFICATION FOR DETAILED REQUIREMENTS AND JOINING METHODS.

ALLOWABLE MATERIAL

CAST IRON PIPE: CISPI 301, HUBLESS. CAST IRON.

COPPER TUBE: TYPE L, DRAWN

BASIC PLUMBING REQUIREMENTS

1. CONDITIONS

1.1. UNLESS OTHERWISE NOTED, THE WORK DESCRIBED ON THE PLANS AND SPECIFICATIONS SHALL INCLUDE THE FURNISHING AND INSTALLATION OF ALL LABOR AND MATERIALS NECESSARY FOR COMPLETE AND OPERATIONAL HVAC AND PLUMBING SYSTEMS. CONTRACTOR SHALL

FURNISH THESE EVEN IF ITEMS REQUIRED TO ACHIEVE THIS (I.E. OFFSETS, ISOLATION AND BALANCING DEVICES, MAINTENANCE CLEARANCES, ETC.) ARE NOT SPECIFICALLY SHOWN.

1.2. ALL CAPACITIES ARE SCHEDULED AT A JOBSITE ALTITUDE OF 6100 FT ABOVE SEA LEVEL

2. CODES AND REGULATIONS

2.1. COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES, REGULATIONS AND ORDINANCES, AND THE LATEST APPLICABLE REQUIREMENTS OF THE 2015 INTERNATIONAL PLUMBING CODE, INTERNATIONAL BUILDING CODE, LATEST EDITIONS OF NFPA, PPRBD REGIONAL AMENDMENTS, AND

REGULATIONS OF THE UTILITY COMPANY FURNISHING SERVICE AS INTERPRETED BY THE LOCAL INSPECTION AUTHORITY WHO SHALL HAVE FINAL JURISDICTION.

2.2. COMPLY ALSO WITH ALL OSHA REQUIREMENTS AND DIRECTIVES.

3. DEFINITIONS

3.1. DEFINITIONS OF DIVISION 1 AND GENERAL CONDITIONS OF THIS SPECIFICATION ALSO APPLY TO DIVISION 22-23 CONTRACT.

3.2. "PROCUREMENT REQUIREMENTS" CONSTITUTE THE SOLICITATION, INSTRUCTIONS FOR PROCUREMENT, AVAILABLE INFORMATION, AND PROCUREMENT FORMS AND SUPPLEMENTS.

3.3. “CONTRACT DOCUMENTS” CONSTITUTE THE CONTRACTING REQUIREMENTS, SPECIFICATIONS, CONTRACT DRAWINGS, PRE-CONTRACT REVISIONS (ADDENDA), CLARIFICATIONS AND PROPOSALS, AND CONTRACT MODIFICATIONS PREPARED BY ARCHITECT FOR CONTRACTOR'S BID OR

CONTRACTOR'S NEGOTIATIONS WITH THE OWNER.

3.4. "CONSTRUCTION DOCUMENTS" INCLUDE THE "PROCUREMENT REQUIREMENTS", "CONTRACT DOCUMENTS", AND ANY RESOURCE DRAWINGS.

3.5. “CONSTRUCTION SUBMITTALS” AND SIMILAR TERMS FOR DIVISION 22-23 WORK REFER TO SHOP DRAWINGS, COORDINATION DRAWINGS, PRODUCT DATA, SAMPLES, QA/QC SUBMITTALS, INFORMATIONAL SUBMITTALS, AND CONSTRUCTION PHOTOGRAPHS PREPARED BY THE CONTRACTOR

THAT CONVEY INFORMATION ABOUT SYSTEMS, EQUIPMENT, MATERIALS, PRODUCTS, AND ADMINISTRATIVE MATTERS, AND ARE NOT CONSIDERED CONSTRUCTION DOCUMENTS.

3.6. “(N)” INDICATES “NEW” EQUIPMENT TO BE PROVIDED UNDER THIS CONTRACT.

3.7. “(E)” INDICATES “EXISTING” EQUIPMENT ON SITE WHICH MAY OR MAY NOT NEED TO BE RELOCATED AS A PART OF THIS WORK.

3.8. “(R)” INDICATES EXISTING EQUIPMENT TO BE RELOCATED AS PART OF THIS WORK.

3.9. “FURNISH” MEANS TO “SUPPLY” AND USUALLY REFERS TO AN ITEM OF EQUIPMENT.

3.10. “INSTALL” MEANS TO “SET IN PLACE, CONNECT AND PLACE IN FULL OPERATIONAL ORDER”.

3.11. “PROVIDE” MEANS TO “FURNISH AND INSTALL”.

3.12. “EQUIVALENT” MEANS “MEETS THE SPECIFICATIONS OF THE REFERENCE PRODUCT OR ITEM IN ALL SIGNIFICANT ASPECTS.” SIGNIFICANT ASPECTS SHALL BE AS DETERMINED BY THE ARCHITECT.

3.13. “WORK BY OTHER(S) DIVISIONS”; “RE:_____ DIVISION”, AND SIMILAR EXPRESSIONS MEAN WORK TO BE PERFORMED UNDER THE CONTRACT DOCUMENTS, BUT NOT NECESSARILY UNDER THE DIVISION OR SECTION OF THE WORK ON WHICH THE NOTE APPEARS. IT IS THE

CONTRACTOR'S SOLE RESPONSIBILITY TO COORDINATE WORK OF THE CONTRACT BETWEEN HIS/HER SUPPLIERS, SUBCONTRACTORS AND EMPLOYEES. IF CLARIFICATION IS REQUIRED, CONSULT ARCHITECT BEFORE SUBMITTING BID.

3.14. BY INFERENCE, ANY REFERENCE TO A “CONTRACTOR” OR “SUB-CONTRACTOR” MEANS THE ENTITY WHICH HAS CONTRACTED WITH THE OWNER FOR THE WORK OF THE CONTRACT DOCUMENTS.

3.15. “ENGINEER” MEANS THE DESIGN PROFESSIONAL FIRM WHICH HAS PREPARED THESE CONTRACT DOCUMENTS. ALL QUESTIONS, SUBMITTALS, ETC. OF THIS DIVISION SHALL BE ROUTED TO THE ARCHITECT THROUGH PROPER CONTRACTUAL CHANNELS.

4. DRAWINGS AND SPECIFICATIONS

4.1. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND SHALL NOT BE SCALED. THEY SHOW CERTAIN PHYSICAL RELATIONSHIPS WHICH MUST BE ESTABLISHED WITHIN THE DIVISION 22 WORK AND ITS INTERFACE WITH OTHER WORK. ESTABLISHING THIS RELATIONSHIP IN THE FIELD IS THE

EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR. THIS DIVISION SHALL COORDINATE ITS WORK WITH ALL DIVISIONS OF THE WORK AND ADJUST ITS WORK AS REQUIRED BY ACTUAL CONDITIONS OF THE PROJECT.

4.1.1. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING A BID TO BECOME THOROUGHLY FAMILIAR WITH THE ACTUAL CONDITIONS OF THE PROJECT.

4.1.2. CERTAIN SYSTEMS REQUIRE ENGINEERING OF INSTALLATION DETAILS BY CONTRACTOR. UNLESS FULLY DETAILED IN THE CONTRACT DOCUMENTS, SUCH ENGINEERING IS THE EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR.

4.1.3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHERE CLEARANCES ARE LIMITED, AND WHERE INSTALLATION DRAWINGS OR SCHEMATICS, “CONSTRUCTION DRAWINGS”, OR COORDINATION DRAWINGS MAY BE REQUIRED. THE CONTRACTOR SHALL PREPARE ALL SUCH

COORDINATION DRAWINGS AS PART OF THE BASE CONTRACT. SUCH DRAWINGS MAY BE SUBMITTED TO THE ARCHITECT FOR RECORD AND COMMENT (AT THE CONTRACTOR'S OPTION).

4.2. REFER TO ARCHITECTURAL AND CIVIL DRAWINGS AND SPECIFICATIONS, AS A PART OF THIS SET, AND BE RESPONSIBLE FOR ALL INFORMATION CONTAINED THEREIN THAT AFFECTS MECHANICAL WORK.

4.3. LAY OUT ALL WORK IN ADVANCE. DO NOT DEFACE WORK OF OTHER TRADES.

5. PERMITS

5.1. SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, LICENSES, UTILITY COMPANY CHARGES AND INSPECTIONS IN CONNECTION WITH THE MECHANICAL WORK.

6. COORDINATION

6.1. ORDER THE PROGRESS OF THE WORK TO CONFORM TO THE PROGRESS OF OTHER TRADES. COORDINATE ALL ELECTRICAL INSTALLATION AND ROUGH-IN AS REQUIRED.

7. WORKMANSHIP

7.1. PROVIDE A COMPETENT FOREMAN ON THE JOB AT ALL TIMES. ACCOMPLISH ALL WORK IN A NEAT, WORKMANLIKE, FIRST-QUALITY MANNER COMPATIBLE WITH GOOD COMMERCIAL PRACTICES AND STANDARDS. PROVIDE COMPETENT WORKMEN.

8. SHOP DRAWINGS AND MATERIALS LIST

8.1. SUBMIT COMPLETE MANUFACTURER'S SHOP DRAWINGS AND MATERIAL LISTS FOR APPROVAL OR AS REQUIRED IN DIVISION 1. PRIOR TO SUBMITTING THE SHOP DRAWINGS, REVIEW AND CERTIFY SAME AS TO COMPLIANCE WITH THE PLANS AND SPECIFICATIONS AND FOR DIMENSIONAL

SUITABILITY FOR THE APPLICATION. ALL PROPOSED DEVIATIONS FROM SPECIFICATIONS MUST BE CLEARLY LISTED UNDER A PROMINENT HEADING ENTITLED “DEVIATIONS”. INCLUDE ALL EQUIPMENT, VALVES, PIPING, AND APPURTENANCES.

8.2. PROVIDE MATERIAL AS SPECIFIED. SUBSTITUTIONS MAY BE CONSIDERED BEFORE THE CONTRACT DATE AS LONG AS DEDUCT ALTERNATE IS SUBMITTED AT BID TIME. SUBMIT SUBSTITUTIONS SEPARATELY FOR EACH PRODUCT WITH SUPPORTING DATA, DRAWINGS AND SAMPLES AS

APPROPRIATE, INCLUDING:

8.2.1. ITEMIZED COMPARISON OF THE QUALITIES OF THE PROPOSED SUBSTITUTION WITH THAT SPECIFIED.

8.2.2. CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK BECAUSE OF THE SUBSTITUTION.

8.2.3. COST DATA COMPARING THE PROPOSED SUBSTITUTION WITH THE PRODUCT SPECIFIED.

8.2.4. THE ARCHITECT WILL BE THE JUDGE OF THE ACCEPTABILITY OF THE PROPOSED SUBSTITUTION.

8.2.5. ALL MATERIALS SHALL BE NEW AND BEAR THE UNDERWRITERS' LABORATORIES, INC. APPROVAL, PROVIDED A STANDARD HAS BEEN ESTABLISHED FOR THE MATERIAL.

8.2.6. ALL EQUIPMENT SHALL MEET OR EXCEED MINIMUM REQUIREMENTS OF SMACNA AND ASHRAE.

9. INSTALLATION

9.1. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH INFORMATION AS INDICATED ON THE DRAWINGS AND IN FULL ACCORD WITH MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS.

10. CUTTING AND PATCHING

10.1. PROVIDE ALL CUTTING, CHANNELING, CHASING, DRILLING, ETC., OPERATIONS AS MAY BE REQUIRED FOR THE MECHANICAL WORK. IN GENERAL, ALL SUCH OPERATIONS SHALL BE HELD TO A MINIMUM.

10.2. ALL PATCHING AND PAINTING SHALL BE DONE BY THE CONTRACTOR.

11. TEMPORARY CONSTRUCTION

11.1. PROVIDE TEMPORARY HEAT AND WATER FOR CONSTRUCTION AS REQUIRED. USE OF EXISTING HEAT AND UTILITIES IS NOT ACCEPTABLE WITHOUT PRIOR WRITTEN PERMISSION OF THE ARCHITECT.

12. INTERRUPTION OF EXISTING SERVICES

12.1. SHUTDOWN, WHEN NECESSARY, SHALL BE SCHEDULED THREE (3) WEEKS IN ADVANCE WITH THE OWNER AND PERFORMED DURING NON-WORKING HOURS (7:00PM - 6:00AM). INTERRUPTION SHALL BE ONLY AT OWNER APPROVED TIMES.

13. GUARANTEE

13.1. GUARANTEE ALL MATERIALS, LABOR, WORKMANSHIP AND THE SUCCESSFUL OPERATION OF ALL EQUIPMENT INSTALLED UNDER THIS CONTRACT FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE AGAINST DEFECTS AND FAULTY WORKMANSHIP.

13.2. REPAIR OR REPLACE, AT NO EXPENSE TO THE OWNER, ALL DEFECTS WHICH MAY ARISE DURING THIS TIME DUE TO INFERIOR OR DEFECTIVE MATERIALS, EQUIPMENT OR WORKMANSHIP.

14. RECORD DRAWINGS

14.1. MAINTAIN A COMPLETE SET OF MECHANICAL DRAWINGS AT THE JOB SITE WITH ALL CHANGES TO CONTRACT DOCUMENTS NEATLY MARKED THEREON IN A CONTRASTING COLOR. THIS SHALL BE A SEPARATE SET OF DRAWINGS NOT USED FOR CONSTRUCTION PURPOSES, WHICH

SHALL BE KEPT UP TO DATE AS THE JOB PROGRESSES AND SHALL BE MADE AVAILABLE FOR OBSERVATION BY THE ARCHITECT AT ALL TIMES. SUBMIT A COMPLETE RECORD SET OF DRAWINGS INCORPORATING ALL ADDENDUMS, BULLETINS AND INFORMATION REQUESTS TO THE

ARCHITECT UPON COMPLETION OF THE PROJECT. PROVIDE ELECTRONIC CAD AND PDF FILES OF RECORD DRAWINGS ALONG WITH HARD COPY OF DRAWINGS.

15. DEMONSTRATION

15.1. DEMONSTRATE THE OPERATION OF ALL SYSTEMS FOR THE OWNER AT A TIME AS DIRECTED BY THE ARCHITECT.

16. MAINTENANCE MANUALS

16.1. PRIOR TO COMPLETION OF PROJECT, SUBMIT FOUR (4) SETS OF OPERATION AND MAINTENANCE MANUALS IN THREE RING BINDERS.

17. EXISTING BUILDING

17.1. THE CONTRACTOR'S ATTENTION IS CALLED TO THE FACT THAT THE EXISTING BUILDING WILL BE OCCUPIED BY THE OWNER DURING CONSTRUCTION. CONTINUED OPERATION OF THE FACILITY SHALL NOT BE HINDERED BY THIS WORK. THE CONTRACTOR SHALL ACCOUNT FOR ALL

ADDITIONAL COSTS WHICH MAY BE INCURRED BY HIM DUE TO THE DIFFICULTY OF WORKING OVER AND AROUND EMPLOYEES, DESKS, EQUIPMENT, ETC.; AND DUE TO THE HOURS OF THE DAY IN WHICH AN AREA MAY BE AVAILABLE WHEN SUBMITTING HIS BID.

17.2. MATCH THE MATERIAL AND CONSTRUCTION METHODS OF ALL RELOCATED PIPE, CONDUITS, ETC. WHICH ARE TO BE RELOCATED WITH THAT OF THE ORIGINAL.

17.3. DURING DEMOLITION OPERATIONS, ALL PERSONS AND PROPERTY SHALL BE PROTECTED. THE WORK SHALL PROCEED IN SUCH A MANNER SO AS TO MINIMIZE ANY SPREADING OF DUST, DEBRIS AND FLYING PARTICLES, AND SO THAT ANY RELATED EFFECTS OF THE DEMOLITION DO

NOT INTERFERE WITH SURROUNDING EQUIPMENT, PERSONNEL OR THE OPERATION OF THE BUILDING.

17.4. MINIMIZE DISRUPTIONS TO MECHANICAL AND ELECTRICAL SYSTEMS IN OCCUPIED AREAS. COORDINATE ANY REQUIRED SYSTEM OUTAGES WITH THE ARCHITECT IN ADVANCE.

18. TENANT FINISH

18.1. NO INCREASE ON CONTRACT SUM WILL BE ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING CONDITIONS. COORDINATE AND ADJUST ALL WORK BETWEEN TRADES AND EXISTING CONDITIONS IN ORDER TO ACCOMPLISH A NEAT, INTEGRATED AND EFFICIENT INSTALLATION.

18.2. EXAMINE THE CONTRACT DOCUMENTS OF ALL TRADES (E.G., THE ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL LIGHTING PLAN, ETC.).

18.3. COORDINATE NECESSARY EQUIPMENT AND PIPING LOCATIONS SO THAT THE FINAL INSTALLATION IS COMPATIBLE WITH THE MATERIALS AND EQUIPMENT OF THE OTHER TRADES.

BASIC MECHANICAL MATERIALS AND METHODS

1. PRODUCTS

1.1. ACCESS PANELS.

1.1.1. REFER TO ARCHITECTURAL DOCUMENTS FOR FINISHES AND PANEL TYPES.

1.1.2. DOORS SHALL BE A MINIMUM OF 16 GAUGE STEEL, UNLESS REQUIRED OTHERWISE FOR FIRE RATING.

1.1.3. PROVIDE WITH CONCEALED OR FLUSH MOUNT LATCHES.

1.1.4. PROVIDE WITH FIRE RATING EQUIVALENT TO CONSTRUCTION WHICH INSTALLED.

1.2. FIRE-STOPPING MATERIALS.

1.2.1. PRODUCTS TO BE USED SHALL HAVE BEEN TESTED IN ACCORDANCE WITH ASTM E 814-88, “AND UL 1479 TEST METHOD FOR THROUGH PENETRATIONS”, AND BE LISTED IN THE UL FIRE RESISTANCE DIRECTORY.

1.2.2. PROVIDE FASTENERS, RESTRICTING COLLARS, BACKING MATERIALS, AND PROTECTIVE COATINGS AS REQUIRED TO COMPLY WITH THE UL SYSTEM LISTING

2. APPLICATION

2.1. CUTTING AND PATCHING.

2.1.1. WHERE CUTTING AND PATCHING IS REQUIRED, ARCHITECTURAL REQUIREMENTS GOVERN.

2.1.2. KEEP CUTTING TO A MINIMUM WHERE REQUIRED.

2.1.3. PROVIDE PATCHING TO MATCH EXISTING AT A MINIMUM.

2.1.4. DO NOT CUT OR DRILL THROUGH STRUCTURAL ITEMS WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT.

2.2. ACCESS PANELS

2.2.1. FURNISHED & LOCATED BY DIVISION 22, INSTALLED BY TRADE RESPONSIBLE FOR SURFACE IN WHICH IT IS INSTALLED.

2.2.2. COORDINATE EXACT LOCATION WITH ARCHITECT OR ARCHITECTURAL DRAWINGS.

2.3. FIRE-STOPPING

2.3.1. INSTALL FIRESTOPPING MATERIALS IN ACCORDANCE WITH THEIR UL AND ASTM TESTED METHODS.

2.3.2. INSTALL FIRE STOPPING AT ALL PENETRATIONS THROUGH FIRE-RATED CONSTRUCTION.

IDENTIFICATION

1. LABEL ALL NEW PIPING.

2. PROVIDE FULL BAND OR STRIP TYPE MARKERS AND FLOW ARROWS ON PIPING.

3. PROVIDE LABEL COLORS TO COMPLY WITH ANSI A13.1.

PLUMBING PIPE AND PIPE FITTINGS

1. DOMESTIC WATER, SIZE FOUR INCH AND UNDER:

1.1. PIPE: COPPER TUBE, HARD TEMPER, TYPE L.

1.2. FITTINGS: WROUGHT COPPER, OR CAST BRONZE.

1.3. BRAZED, SOLDERED OR PROPRESS JOINTS.

1.4. BALL VALVES:

1.4.1. ALL BRONZE, FULL PORT, 150 SWP, ADJUSTABLE PACKING GLAND NUT, TWO PIECE DESIGN.

2. SOIL AND VENT PIPING, ALL SIZES:

2.1. ABOVE GROUND:

2.1.1. CAST IRON NO HUB, NEOPRENE GASKET AND STAINLESS STEEL SLEEVE JOINT.

2.1.2. COUPLINGS SHALL BE HEAVY DUTY, ALL STAINLESS STEEL: 3" WIDE 304 STAINLESS STEEL SHIELD; "FLOATING" EYELET. CISPI 301, CERTIFIED BY NSF INTERNATIONAL, BEAR BOTH CISPI 301 AND NSF INTERNATIONAL COLLECTIVE TRADEMARKS ON COUPLINGS.

2.1.2.1. TORQUE TO MINIMUM 30 INCH POUNDS PER MANUFACTURER'S RECOMMENDATION.

2.1.2.2. HUSKY SERIES 4000 OR EQUIVALENT.

3. PIPING INSTALLATION:

3.1. ALL PIPING SHALL BE ADEQUATELY SUPPORTED FROM THE BUILDING STRUCTURE TO PREVENT SAGGING, POCKETING, SWAYING OR DISPLACEMENT BY MEANS OF HANGERS AND SUPPORTS. PIPING SHALL NOT BE SUPPORTED BY EQUIPMENT.

3.2. SUPPORT CAST IRON PIPE EACH SIDE OF EACH JOINT.

3.3. FLUSH OUT PIPING AND REMOVE CONTROL DEVICES BEFORE PERFORMING PRESSURE TEST. PRESSURIZE PIPING AT FULL HEIGHT COLUMN OF WATER IN PIPING. IF LEAKAGE IS OBSERVED , REPAIR LEAKS AND RETEST.

3.4. SLOPE ALL GRAVITY DRAINAGE PIPING AS REQUIRED BY PLANS AND IN ACCORDANCE WITH APPLICABLE CODES.

PLUMBING FIXTURES

1. PLUMBING FIXTURES MUST CONFORM TO THE STANDARDS SET FORTH BY THE INTERNATIONAL PLUMBING CODE VERSION ENFORCED BY CODE AUTHORITIES AND IAPMO.

2. COMPLY WITH MAXIMUM WATER REQUIREMENT OF PLUMBING FIXTURES: TANK TYPE WATER CLOSET 1.28 GPM, URINAL 0.5 GPM, LAVATORY 0.5 GPM & SHOWER 1.5 GPM.

PIPING AND EQUIPMENT INSULATION

1. MANUFACTURERS

1.1. JOHNS-MANVILLE, ARMSTRONG, OWENS-CORNING, KNAUF.

2. MATERIALS

2.1. SEAL ALL PIPING WHICH IS NORMALLY COLDER THAN AMBIENT WITH VAPOR BARRIER RATED MASTIC.

2.2. TYPE A: FIBERGLASS PIPE INSULATION WITH SELF ADHESIVE ALL SERVICE VAPOR BARRIER JACKET. FITTINGS INSULATED WITH FIBERGLASS INSERTS IN PVC FITTING COVERS. ALL MATERIALS FLAME SPREAD 25, SMOKE DEVELOPED 50.

2.3. TYPE B: FLEXIBLE ELASTOMERIC CLOSED CELL PIPE INSULATION, FLAME SPREAD 25, SMOKE DEVELOPED 50.

3. APPLICATION

3.1. PIPING

3.1.1. ABOVE GROUND DOMESTIC COLD WATER.

3.1.1.1. ALL SIZES, ½" THICK TYPE A OR B.

3.1.1.2. PVC JACKET WHERE EXPOSED IN NORMALLY OCCUPIED AREAS FOR NEW AND EXISTING PIPING.

3.1.2. ABOVE GROUND DOMESTIC HOT WATER AND HOT WATER RECIRCULATION.

3.1.2.1. LESS THAN 2-1/2" - 1" THICK TYPE A OR B.

3.1.2.2. PVC JACKET WHERE EXPOSED IN NORMALLY OCCUPIED AREAS FOR NEW AND EXISTING PIPING.

TEST-ADJUST-BALANCE

1. NOTIFY THE CONTRACTOR OF CONDITIONS DETRIMENTAL TO THE PROPER COMPLETION OF THE TEST-ADJUST-BALANCE WORK PRIOR TO THE START OF BALANCING. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.

2. TEST PRESSURE PIPING TO 150 PSI FOR FOUR (4) HOURS; GRAVITY DRAIN PIPING TO TOP OF SYSTEM.3. SUBMIT COMPLETE BALANCE REPORTS TO THE ARCHITECT.

4. SUBMIT APPROVED BALANCE REPORT TO INSPECTOR AT TIME OF FINAL INSPECTION.

5. AFTER SYSTEM HAS BEEN IN OPERATION FOR ONE (1) MONTH, THOROUGHLY CHECK SYSTEM AND DEVICES FOR WATER (PLUMBING) LEAKAGE.

6. CHLORINATE DOMESTIC WATER SYSTEMS PER CODE AND CERTIFY.

EXISTING BUILDING HAS A 4" DOMESTIC CW SYSTEM WITH REDUCED PRESSURE BACKFLOWPREVENTER AND METER. THIS PROJECT HAS REMOVED ONE (1) EXISTING PLUMBING FIXTURE AND REPLACED SEVENTEEN (17) EXISTING FIXTURES WITH NEW LOW FLOW FIXTURES. THE LOAD FOR THE ENTIRE BUILDING HAS DECREASED. THE EXISTING WATER ENTRY ASSEMBLY HAS NOT CHANGED.

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

2:4

2:0

4 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

PLUMBINGSPECIFICATIONS

P0.2

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

07/15/20

Page 21: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

2 3 4 5 6 7 8 9

10

9.48.98.2

G

H

I

1.5

D

E

F

P3

P3

P3

P3

P1

P2

P4

P4P4

P4

P5

P5

P5

P5 P5

OFFICE

H025

OFFICE

H022

OFFICE

H021

OFFICE

H020

BREAK ROOM

H023

TOILET

H024

FEMALELOCKER RM

H013A

MALELOCKER RM

H014A

COMMONELECT

H017

COURT ROOM

H035

HOLDING

H036

CORRIDOR

H036A

VESTIBULE

H037

FEMALES

H013

MALES

H014

COMMANDSTAFF LKR RM

H037A

STORAGE

H027

CORRIDOR

H000

ACA

H028

OFFICE

H031

MAIL ROOM

H030

STORAGE

H029

JUDGESCHAMBER

H034

CLERK

H032

TOILET

H033

SALLYPORT

I053

OFFICE

I007

CITY ID

I045

BREAK ROOM

H012

TELEPHONEROOM

H011

COMPUTERROOM

H010

STORAGE

H007

OFFICE

H008

CONFERENCEROOM

H009

RECEPTION

H001

OFFICE

H006

OFFICE

H005

OFFICE

H004

OFFICE

H003

OFFICE

H002

SECURITYOFFICE

I001A

LOBBY

I001

WOMENS

I003

MENS

I002

SALLYPORT

I004

VEST

I004A

WOMENSTOILET

I043

MENS TOILET

I042

TELECOMROOM

I041

ELECTRICALROOM

I040

OFFICE

I039

OFFICE

I038

INMATEWAITING

I044

INTERVIEW

I046

INTERVIEW

I047

BRIEFING

I034

BREAK ROOM

I035

LOBBY

I000A

VESTIBULE

I000

TOILET

I036

STORAGE

I033

INTAKE

I037

INTERVIEW

I031

INTERVIEW

I030

INTAKE LOBBY

I029

INTERVIEW

I028

INTEERVIEW

I027

INTOX

I024

JANITORS

I023

INTOX

I025

SALLYPORT

I026

JANITORS

I020

MEDICALINTERVIEW

I021

MEDICALINTERVIEW

I022

CELL 9

I019CELL 8

I018

CELL 7

I017

INMATEWAITING

I010

CELL 6

I016

CELL 5

I015

CELL 4

I014

CELL 3

I013

CELL 2

I012

CELL 1

I011

WOMENSPROCESS

I009

Room

I049

MENSPROCESS

I008

P3 P1

P1P2

P3P1

P1

SH-1

SH-1

SH-1

SH-1

L-1

L-1

WC-2

UR-1

WC-2

WC-1

L-1

L-1

L-1 WC-2

WC-2UR-1

L-1

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

2:4

2:0

5 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

PLUMBING FLOORPLAN

P1.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

1/8" = 1'-0"1 PLUMBING PLAN

PLUMBING GENERAL NOTES

I CONTRACTOR SHALL FIELD VERIFY SIZES ANDLOCATION OF PIPING PRIOR TO BEGINNINGWORK.

II REFER TO GENERAL DEMOLITION NOTES ONARCHITECTURALDRAWINGS FOR ADDITIONALINFORMATION AND SCOPE OF WORKREQUIREMENTS. REFER TO ARCHITECTURALDRAWINGS FOR DIMENSIONED FLOOR PLANS.

III RESERVE RIGHT OF OWNER TO FIRST REFUSALFOR ALL EXISTING PLUMBING FIXTURES OREQUIPMENT REMOVED. FIXTURES ANDEQUIPMENT NOT ACCEPTED FOR OWNER USE,AND ALL DEBRIS, SHALL BE REMOVED FROMSITE FOR PROPER DISPOSAL.

IV REMOVE ALL EXISTING PIPING SERVINGPLUMBING FIXTURES OR EQUIPMENT BEINGREMOVED. REMOVE PIPING BACK TO EXISTINGMAINS AND CAP OR PLUG AS REQUIRED OR ASSHOWN. FIELD COORDINATE WITH OWNERREPRESENTATIVE AND ALL TRADES TO MINIMIZEDISRUPTION OF EXISTING SERVICES.

V ALL APPLICABLE PLUMBING FIXTURES,APPURTENANCES AND PIPING SHALL COMPLYWITH "REDUCTION OF LEAD IN DRINKING WATERACT" PUBLIC LAW 111-380.

VI WHERE EXISTING WASTE, VENT AND WATERPIPES PROVIDE ROUGH-IN FOR NEW FIXTURE,LEAVE EXISTING PIPES SUITABLE FOR NEWCONNECTIONS.

VII RELOCATE AND ADD NEW SPRINKLER HEADSAND SIZE PIPES PER NFPA 13.

VIII SEAL ALL PENETRATIONS THROUGH RATEDWALLS AND FLOORS TO MAINTAIN THEINTEGRITY OF THE RATING.

IX MATCH EXISTING MATERIALS FOR LIKE NEWWORK.

X USE CURRENT CODE FOR PLUMBING PIPEINSULATION.

KEY NOTES

P1 REPLACE EXISTING WATER CLOSET WITHNEW. CONFIRM IN FIELD AND MATCHEXISTING BOLT PATTERNS.

P2 REMOVE EXISTING URINALS. REPLACE WITHONE NEW URINAL AND NEW WALL CARRIEREQUAL TO ZURN Z122.

P3 REPLACE EXISTING LAVATORY WITH NEW.PROVDE WATTS LFUSG-B-M2 MIXING VALVE.CONNECT 2"SAN, 2"VENT AND 1/2"CW & HWTO EXISTING. PROVIDE NEW RISERS,SUPPLIES AND TRAP.

P4 REPLACE EXISTING SHOWER VALVES WITHNEW. CONFIRM IN FIELD AND MATCHEXISTING BOLT PATTERNS.

P5 EXISTING PLUMBING FIXTURES TO REMAIN.

07/15/20

Page 22: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

2:4

2:0

6 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

PLUMBINGSCHEDULES

P6.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

PLUMBING FIXTURE SCHEDULE

CODE FIXTURE DESCRIPTION LOCATION

MIN CW

CONN

MIN. HW

CONN

MIN. SAN

CONN

MIN. VENT

CONN. MANUFACTURER MODEL NO. FAUCET/FLUSH VALVE REMARKS

L-1 LAVATORY (ADA) COUNTER MOUNTED - 0.5 GPM RESTROOMS 1/2" 1/2" 1 1/2" 1 1/2" SLOAN SS-3102 SLOAN BASYS EFX-250-4-BAT-BDT-CP-0.5-MLM-IR-FCT ADA, EBF, CT, GS, PT, ST

SH-1 SHOWER (ADA) HAND HELD SHOWER - 1.5 GPM LOCKER RESTROOMS 1/2" 1/2" 0" 0" BRADLEY WS-1WCA - ADA, AS, HH W/ EF VALVE

UR-1 URINAL (ADA) WALL HUNG - EBFV - 0.5 GPF RESTROOMS 3/4" 0" 2" 1 1/2" SLOAN SU-1006 SLOAN G2 SENSOR G2 8186-0.5 ADA, EBFV, VC, WFC, TS W/ SS DRAIN GUARDS

WC-1 WATER CLOSET FLOOR MOUNTED - FV - 1.28 GPF RESTROOMS 1" 0" 4" 2" SLOAN ST-2009 SLOAN G2 SENSOR G2 8111-1.28 EBFV, BO, FM, S, VC, TS, EB

WC-2 WATER CLOSET (ADA) FLOOR MOUNTED - FV - 1.28 GPF RESTROOMS 1" 0" 4" 2" SLOAN ST-2029 SLOAN G2 SENSOR G2 8111-1.28 ADA, EBFV, BO, FM, S, VC, TS, EB

PB PRESSURE BALANCING

PC POLISHED CHROME

PES PORCELAIN ENAMELED STEEL

PT CHROME PLATED BRASS P-TRAP WITH CLEANOUT

PTB PRESSURE - TEMPERATURE BALANCED

RB REGULAR/PLAIN BOWL

S SOLID WHITE ELONGATED OPEN FRONT SEAT, LESS COVER WITH CHECK HINGE

SC SOLID WHITE ELONGATED OPEN FRONT SEAT WITH COVER

SP SOLID WHITE PLAIN-RIM OPEN FRONT SEAT, LESS COVER WITH CHECK HINGE

SS STAINLESS STEEL

ST CHROME PLATED BRASS ANGLE LOOSE KEY STOPS

TS TOP SPUD

VB VACUUM BREAKER

VC VITREOUS CHINA

VR VANDAL RESISTANT

WFC WALL FIXTURE CARRIER

WH WALL HUNG

WO WALL OUTLET

GENERAL NOTES

1 COLD WATER AND DRAINAGE FIXTURE UNITS AND SIZES ARE BASED ON THE 2015 INTERNATIONAL PLUMBING CODE FOR DESIGN BASIS.

2 ALL EXPOSED PIPING SERVICING ADA FIXTURES SHALL BE INSULATED PER ADA REQUIREMENTS WITH TRUEBRO HANDI LAV-GUARD SYSTEM.

3 ALL FIXTURES ARE WHITE UNLESS OTHERWISE NOTED. ALL TRIM IS CHROME UNLESS OTHERWISE INDICATED.

4 REFER TO ARCHITECTURAL DRAWINGS FOR ALL MOUNTING HEIGHTS.

5 PROVIDE ALL PLUMBING FIXTURE ACCESSORIES, (CHROME PLATED), SUCH AS BUT NOT LIMITED TO TRAPS, STRAINERS, SUPPLIES (WHEELSTOPS, ANGLE STOPS WITH LOOSE KEY STOPS) VERTICAL RISER TUBES, (AERATORS, VANDAL RESISTANT AERATORS), ETC.

6 PROVIDE SHOCK ARRESTORS AT ALL TOILET ROOM GROUPS AND QUICK-CLOSING VALVES. LOCATE BEHIND WALL OR ABOVE CEILING.COORDINATE LOCATION WITH ARCHITECT AND PROVIDE ACCESS PANEL WHERE REQUIRED IN HARD SURFACES.

7 ALL PLUMBING FIXTURES SHALL COMPLY WITH "REDUCTION OF LEAD IN DRINKING WATER ACT" PUBLIC LAW 111-380.

8 PROVIDE SHUTOFF BALL VALVES BEHIND ACCESS PANEL IN HOT AND COLD WATER SUPPLY PIPES TO MSB'S.

9 WHERE CONNECTION SIZE IS NOTED AS 0", SIZE AS REQUIRED.

ABBREVIATIONS

ADA AMERICANS WITH DISABILITIES ACT AND ANSI 117.1 APPROVED

AS ANTISCALD

BO BOTTOM OUTLET

CT COUNTER TOP

EB ELONGATED BOWL

EBF ELECTRONIC, BATTERY OPERATED FAUCET

EBFV ELECTRONIC, BATTERY OPERATED FLUSH VALVE

EWF ELECTRONIC, WIRED FAUCET W/ TRANSFORMER

EWFV ELECTRONIC, WIRED FLUSH VALVE W/ TRANSFORMER

FM FLOOR MOUNTED

FP FREEZE PROOF

FR FLOW RESTRICTOR

FT TANK

FV FLUSH VALVE

GS CHROME PLATED BRASS GRID STRAINER AND TAIL PIECE

HH HAND HELD SHOWER

IBP INTEGRAL BACKFLOW PREVENTER

MF METERING FAUCET

MV MIXING VALVE

07/15/20

Page 23: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

ABBREVIATIONS

A, AMPACADAAFAFFAFGAHYAMANNANTATSAUTOAUXAWG

BKRBFG

CCABCBCCTVCKTCLGCOCOMBCONDCTCU

dBDISCDLDWG

EEAECEFEGEHCELECELEVEMEMTEOLEQUIPEREWCEWHEXH

FF/AFACPFAAPFBOFCFDRFLAFLEXFLRFLUOR

GALVGENGFIGNDGRC

HDHHHIDHOAHPHPFHPSHTR

IDIMCINCAND

JBOX

KCMILKVAKWKWH

LALFCLPFLTGLV

MAXMBMCMCBMCCMCPMDPMECHMFRMGMHMINMLOMOVMTGMTRMSBMTDMTGMV

AMPEREABOVE COUNTERAMERICANS WITH DISABILITIES ACTAMPERE FUSE/FRAMEABOVE FINISHED FLOORABOVE FINISHED GRADEAIR HANDLING UNITAMMETERANNUNCIATORANTENNAAUTOMATIC TRANSFER SWITCHAUTOMATICAUXILIARYAMERICAN WIRE GAUGE

BREAKERBELOW FINISHED GRADE

CONDUITCABINETCIRCUIT BREAKERCLOSED CIRCUIT TELEVISIONCIRCUITCEILINGCONDUIT ONLYCOMBINATIONCONDUCTORCURRENT TRANSFORMERCOPPER

DECIBELDISCONNECTDAMP LABELDRAWING

EXISTINGEACHELECTRICAL CONTRACTOREXHAUST FANEQUIPMENT GROUNDELECTRIC HEATING COILELECTRIC OR ELECTRICALELEVATOREMERGENCYELECTRIC METALLIC TUBINGF/A END OF LINE RESISTOREQUIPMENTEXISTING TO BE REMOVED/RELOCATEDELECTRIC WATER COOLERELECTRIC WATER HEATEREXHAUST

FUSEFIRE ALARMFIRE ALARM CONTROL PANELFIRE ALARM ANNUNCIATOR PANELFURNISHED BY OTHERSFOOTCANDLESFEEDERFULL LOAD AMPERESFLEXIBLEFLOORFLUORESCENT

GALVANIZEDGENERATORGROUND FAULT CIRCUIT INTERRUPTERGROUNDGALVANIZED RIGID CONDUIT

HEAVY DUTYHAND HOLEHIGH INTENSITY DISCHARGEHAND-OFF-AUTOHORSEPOWERHIGH POWER FACTORHIGH PRESSURE SODIUMHEATER

INSIDE DIAMETERINTERMEDIATE GRADE METALLIC CONDUITINCANDESCENT

JUNCTION BOX

THOUSAND OF CIRCULAR MILLSKILOVOLT AMPEREKILOWATTKILOWATT HOUR

LIGHTNING ARRESTORLIQUIDTIGHT FLEXIBLE CONDUITLOW POWER FACTORLIGHTINGLOW VOLTAGE

MAXIMUMMAIN BREAKERSMECHANICAL CONTRACTORMAIN CIRCUIT BREAKERMOTOR CONTROL CENTERMOTOR CIRCUIT PROTECTORMAIN DISTRIBUTION PANELMECHANICALMANUFACTURERMOTOR GENERATORMANHOLE OR METAL HALIDEMINIMUMMAIN LUGS ONLYMOTOR OPERATED VALVEMOUNTING HEIGHTMOTORMAIN SWITCHBOARDMOUNTEDMOUNTINGMEDIUM VOLTAGE

NNECNCNFNFPANICNLNONTS

OCOD

PPAPBPBXPEPFPHPNLPRPRIPSCoPTPVCPWR

RRERECRGSRMRPM

SECSECTSHTSPDSPDTSPSTSTSTDSWSWBD

TTCTELTELCOTEMPTOTSTTCTTB

UCU/GUHULUONUPS

VV/DVFDVMWW/WHWHMWPWT

XFMRXP

NEUTRALNATIONAL ELECTRICAL CODENORMALLY CLOSEDNON FUSEDNATIONAL FIRE PROTECTION ASSOCIATIONNOT IN CONTRACTNIGHT LIGHTNORMALLY OPENNOT TO SCALE

ON CENTEROUTSIDE DIAMETER

POLEPUBLIC ADDRESSPUSH BUTTONPRIVATE BRANCH EXCHANGEPHOTOELECTRICPOWER FACTORPHASEPANELPAIRPRIMARYPUBLIC SERVICE COMPANYPOTENTIAL TRANSFORMERPOLYVINYL CHLORIDEPOWER

REMOVERELOCATED EXISTINGRECEPTACLERIGID GALVANIZED STEELROOMREVOLUTIONS PER MINUTE

SECONDARY/SECONDSECTIONSHEETSURGE PROTECTION DEVICESINGLE POLE, DOUBLE THROWSINGLE POLE, SINGLE THROWSHUNT TRIPSTANDARDSWITCHSWITCHBOARD

TWIST LOCKTIME CLOCKTELEPHONETELEPHONE COMPANYTEMPORARYTHERMAL OVERLOADTIME SWITCHTELEPHONE TERMINAL CABINET OR CLOSETTELEPHONE TERMINAL BOARD

UNDER COUNTERUNDER GROUNDUNIT HATERUNDERWRITER LABORATORIESUNLESS OTHERWISE NOTEDUNINTERRUPTIBLE POWER SUPPLY

VOLTVOICE/DATAVARIABLE FREQUENCY DRIVEVOLTMETERWATTWITHWATT HOURWATT HOUR METERWATHERPROOFWATERTIGHT

TRANSFORMEREXPLOSION PROOF

ABBREVIATIONS

ANNOTATION LEGEND

SYMBOL DESCRIPTION

RACEWAY LEGEND

SYMBOL

BRANCH CIRCUIT HOMERUN TO PANELBOARDNUMBER OF ARROWS INDICATE NUMBER OFPANEL LEGS. NUMERAL INDICATES CIRCUITBREAKER NUMBER.

POWER

SYMBOL DESCRIPTION

STUD CLG FLOOR WALL

SINGLE RECEPTACLE

DUPLEX RECEPTACLE

FOURPLEX RECEPTACLE

SPECIAL RECEPTACLE

SPECIAL RECEPTACLE

JUNCTION BOX

POWER POLE

SINGLE POLE THERMAL OVERLOAD SWITCH

NON-FUSED DISCONNECT SWITCH

FUSED DISCONNECT SWITCH

PANEL BOARD

TRANSFORMER

X X X X

X X X X

J J J J

T

TO

SYMBOL DESCRIPTION

1

XXXX

#

SHT.

AA-1,3,5

KEYED NOTE TAG

PANELBOARD NAME TAG

DETAIL TAG

IDENTIFIES DINGLE OR MULTIWIRE BRANCHCIRCUITS (THREE CIRCUITS SHOWN) IN HOMERUN TO PANEL AA.

DESCRIPTION

CONCEALED CONDUIT IN WALL OR CEILING

CONDUIT BELOW GRADE OR BELOW SLAB

CONDUIT CAP

CONDUIT CONTINUATION

CONDUIT UP

CONDUIT DOWN

SPECIAL RECEPTACLE MODIFIERS

COMMUNICATIONS

FIRE ALARM

GENERAL NOTES FOR REMODEL

GENERAL ELECTRICAL REQUIREMENTSLIGHTING

1. ALL EXPOSED RACEWAYS ARE TO BE INSTALLED PARALLEL OR PERPENDICULAR TO WALLS OR STRUCTURAL MEMBERS SUCH THAT THEY FOLLOW STRUCTURAL SURFACE CONTOURS AND SHALL BE INSTALLED SUCH THAT THEY DO NOT OBSTRUCT PASSAGEWAYS OR ACCESS TO EQUIPMENT. MULTIPLE RACEWAYS SHOULD BE INSTALLED GROUPED TOGETHER. THE LOCATION OF PUBLICLY VISIBLE RACEWAYS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. (EXTRA TIME SHOULD BE ALLOWED FOR THIS REVIEW AND APPROVAL.)

2. THE DISCONNECTING MEANS FOR ALL MECHANICAL EQUIPMENT SHALL BE ACCESSIBLE AND HAVE THE CLEARANCE IN FRONT AS REQUIRED BY NEC AMENDMENTS.

3. ALL CEILING ATTACHED OBJECTS AND FLOOR ATTACHED EQUIPMENT INCLUDING BUT NOT LIMITED TO PENDANT LIGHTING FIXTURES, CHANDELIERS, GENERAL LIGHTING, MULTIPLE RACEWAYS, GENERATORS, TRANSFORMERS, ELECTRICAL SWITCHGEAR, AND SWITCHBOARDS SHALL BE INSTALLED IN ACCORDANCE WITH SUPPORTING OBJECTS FOR SEISMIC ZONE AS REQUIRED BY STATE AND LOCAL CODES AND PER STRUCTURAL ENGINEERS RECOMMENDATIONS.

4. DATA GIVEN ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED. ABSOLUTE ACCURACY IS NOT GUARANTEED AND THE CONTRACTOR SHALL OBTAIN AND VERIFY EXACT LOCATIONS, MEASUREMENTS, LEVELS, SPACE REQUIREMENTS, POTENTIAL CONFLICTS WITH OTHER TRADES, ETC. AT THE SITE AND SHALL SATISFACTORILY ADAPT HIS WORK TO ACTUAL CONDITIONS AT THE BUILDINGS. THE DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND SHALL NOT BE SCALED. HOWEVER THIS DOES NOT RELIEVE ANY SUB-CONTRACTOR FROM COORDINATING HIS WORK WITH ALL OTHER TRADES AND FROM ADJUSTING HIS WORK AS REQUIRED BY THE ACTUAL CONDITIONS OF THE PROJECT. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING COSTS TO BECOME THOROUGHLY FAMILIAR WITH THE ACTUAL CONDITIONS OF THE PROJECT.

5. COORDINATE AND ADJUST ALL WORK BETWEEN TRADES AND EXISTING CONDITIONS IN ORDER TO ACCOMPLISH A NEAT, INTEGRATED AND EFFICIENT INSTALLATION WHICH INCLUDE BUT ARE NOT LIMITED TO:

a. EXAMINE THE CONTRACT DOCUMENTS OF ALL TRADES (IE. THE ARCHITECTURAL REFLECTED CEILING PLAN, MECHANICAL HVAC DRAWINGS, ELECTRICAL LIGHTING PLAN, FIRE PROTECTION PLAN, ETC.).

b. COORDINATE NECESSARY EQUIPMENT, FIXTURES, ETC. SO THAT THE FINAL INSTALLATION IS COMPATIBLE WITH THE MATERIALS AND EQUIPMENT OF THE OTHER TRADES.

c. THIS CONTRACTOR SHALL ASSIST THE DIVISION 15 CONTRACTOR IN PREPARING SHOP DRAWINGS FOR COORDINATING INSTALLATION OF ALL WORK (IE. LOCATING ALL LIGHTING FIXTURES IN CEILING WITH CEILING CLEARANCES, RACEWAYS, CABLE TRAY, PIPING, EQUIPMENT FOR CLEARANCE THROUGHOUT).

d. THE ELECTRICAL DRAWINGS INDICATE THE ELECTRICAL REQUIREMENTS FOR A SIGNIFICANT PORTION OF THE MECHANICAL AND PLUMBING SYSTEMS. ADDITIONAL MECHANICAL AND PLUMBING EQUIPMENT IS INDICATED ON THE DIVISION 15 DRAWINGS. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE COMPLETE WIRING AND FUSIBLE DISCONNECTING MEANS FOR ALL MECHANICAL AND PLUMBING EQUIPMENT UNLESS OTHERWISE NOTED.

6. DEFINITIONS:

a. "FURNISH" MEANS TO "SUPPLY" AND USUALLY REFERS TO AN ITEM OF EQUIPMENT.

b. "INSTALL" MEANS TO "SET IN PLACE, CONNECT AND PLACE IN FULL OPERATIONAL ORDER".

c. "PROVIDE" MEANS TO "FURNISH AND INSTALL".

d. "EQUIVALENT" MEANS "MEETS THE SPECIFICATIONS OF THE REFERENCE PRODUCT OR ITEM IN ALL SIGNIFICANT ASPECTS." SIGNIFICANT ASPECTS SHALL BE DETERMINED BY THE ENGINEER.

e. "WORK BY OTHER(S) (CONTRACTOR): "RE: DIVISION", AND SIMILAR EXPRESSIONS MEANS WORK TO BE PERFORMED UNDER THE CONTRACT DOCUMENTS, BUT NOT NECESSARILY UNDER THE DIVISION OR SECTION OF THE WORK ON WHICH THE NOTE APPEARS. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO COORDINATE THE WORK OF THE CONTRACT BETWEEN HIS/HER SUPPLIERS, SUBCONTRACTORS, AND EMPLOYEES. IF CLARIFICATION IS REQUIRED, CONSULT ARCHITECT BEFORE START OF WORK.

7. "FIRESTOPPING" REQUIREMENT. ALL PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR FIRE STOPS ASTM-E-814. ALL PENETRATIONS SHALL MEET F AND T RATINGS AS REQUIRED BY THE BUILDING CODE.

8. ALL ELECTRICAL CONDUIT CROSSING BUILDING SEISMIC SEPARATION OR EXPANSION JOINTS SHALL BE PROVIDE WITH APPROVED FLEXIBLE CONNECTORS. REFER TO THE ARCHITECTURAL PLANS FOR ALL EXPANSION JOINT LOCATIONS.

9. WHERE DISCONNECTS ARE INDICATED ON DRAWINGS CONTRACTOR SHALL PROVIDE FINAL CONNECTION TO EQUIPMENT BEING SERVED BY DISCONNECT.

1. OBTAIN STRUCTURAL ENGINEERS APPROVAL PRIOR TO ANY CORE DRILLING OF AN EXISTING SUSPENDED SLAB. X-RAY THE SLAB TO AVOID RE-BAR, ETC.

2. THE INFORMATION ON THE DEMOLITION DRAWINGS REGARDING EXISTING CONDITIONS WAS OBTAINED LARGELY FROM FIELD OBSERVATIONS AND DISCUSSIONS WITH FACILITY PERSONNEL. PROVIDE A SURVEY OF THE EXISTING BUILDING, AND VERIFICATION OF THE EXISTING CONDITIONS.

3. REFER TO THE ARCHITECTURAL DEMOLITION FLOOR PLANS AND REFLECTED CEILING PLANS, TO ESTABLISH THE COMPLETE SCOPE OF WORK.

4. PROVIDE THE REQUIRED NEW CONDUIT, CONDUIT INTERCEPTIONS, JUNCTION BOXES, PULL BOXES, NEW CONDUCTORS, ETC. TO ACCOMPLISH THE WORK, INTEGRATE THE NEW WORK WITH THE EXISTING WHERE INDICATED. MAINTAIN THE CONTINUITY AND OPERATION OF THE EXISTING SYSTEMS IN THE AREAS ADJACENT TO THE REMODELED AREAS.

5. EXISTING BRANCH CIRCUIT CONDUITS MAY BE REUSED FOR THE NEW WORK. UNDER THESE CONDITIONS, PROVIDE ALL NEW CONDUCTORS. CONDUCTOR FILL PER CODE. IN CEILING SPACES, REMOVE ANY EXISTING CONDUITS THAT ARE NOT REUSED.

6. WHERE THE ARCHITECTURAL DRAWINGS INDICATE THAT AN EXISTING PARTITION IS TO BE REMOVED, DISCONNECT AND REMOVE EXISTING ELECTRICAL AND SIGNAL DEVICES, OUTLET BOXES, CONDUIT AND CONDUCTORS. REMOVE CONDUCTORS BACK TO THE LAST ELECTRICAL OR SIGNAL DEVICE TO REMAIN ACTIVE. REFER TO THE DEMO AND MODERNIZATION DRAWINGS FOR THE SCOPE OF THIS WORK.

7. ALL REMOVED LIGHTING FIXTURES, RECEPTACLE OUTLETS, SECURITY, PUBLIC ADDRESS AND FIRE ALARM DEVICES SHALL BE RETURNED TO THE OWNER AS DIRECTED.

8. WHERE THE ELECTRICAL DRAWINGS INDICATE THAT A DEVICE, OF ANY TYPE, IS TO BE REMOVED FROM A PARTITION THAT REMAINS, DISCONNECT AND REMOVE THE DEVICE AND OUTLET BOX. REMOVE THE CONDUCTORS BACK TO THE LAST DEVICE TO REMAIN ACTIVE. CAP THE CONDUIT IN THE PARTITION AND ABANDON. AT THE TOP OF THE PARTITION, INTERCEPT AND CAP THE CONDUIT IN THE CEILING SPACE AT THE FIRST ACCESSIBLE COUPLING.

9. WHERE THE DRAWINGS INDICATE THAT AN EXISTING CONDUIT (BRANCH CIRCUIT OR FEEDER) IS TO BE INTERCEPTED, FOR PURPOSES OF EXTENDING TO A NEW LOCATION, ALWAYS REMOVE THE EXISTING CONDUCTORS AND PROVIDE NEW CONDUCTORS BETWEEN POINTS OF CONNECTION. WHEN THIS WORK REQUIRES REMOVING AN EXISTING WIRING DEVICE (RECEPTACLE OR SWITCH) AT A LOCATION THAT REMAINS, PROVIDE A NEW WIRING DEVICE AND PLATE.

LETTER RATING NEMA NOTES

1

G 125V, 1~, 20A, 2P, 3W DUPLEX 5-20R GROUND FAULT INTERRUPTING

WP 125V, 1~, 20A, 2P, 3W 5-20R GROUND FAULTINTERRUPTING WITHIN-USE WEATHERPROOFCOVER

THE NUMBER OF WIRES INDICATED INCLUDES THE GROUND.1

RECESSED 2'x4' FIXTURE

RECESSED 2'x2' FIXTURE

RECESSED 1'x4' FIXTURE

LINEAR PENDANT FIXTURE

WALL MOUNTED FIXTURE

STRIP LIGHT

PENDANT MOUNTED STRIP LIGHT

RECESSED DOWNLIGHT

WALL SWITCHSUPERSCRIPTS:

2 - 2 POLE SWITCH3 - 3 WAY SWITCH4 - 4 WAY SWITCHTO - THERMAL OVERLOADLV - LOW VOLTAGEP - PILOT LIGHT

SINGLE POLE TOGGLE SWITCH(LOWER CASE LETTERS DENOTES MULTIPLE SWITCHES)

CEILING MOUNTED DUAL TECH OCCUPANCY SENSOR

WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR SWITCH

(LOWER CASE LETTERS DENOTES DUAL LEVEL SWITCHING)

a,b

ab

SYMBOL

CLG FLOOR WALL

DESCRIPTION

TELEPHONE OUTLET, 1V UON

DATA OUTLET, 2D UON

KEY NOTES:

SYMBOL DESCRIPTION

CLG WALL

SPEAKER

SPEAKER WITH STROBE

STROBE

SMOKE DETECTOR

PULL STATION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

PROXIMITY CARD READER

DURESS ALARM

DOOR RELEASE

ELECTRIC STRIKE

R

D

DR

ES

SECURITYONE-LINE SYMBOLS

CONTROL TRANSFORMER

BRANCH CIRCUIT PANELBOARD

BRANCH CIRCUIT PANELBOARD W/ MAIN CIRCUIT BREAKER

UTILITY METER

GROUND

FEEDER IDENTIFIER SYMBOL

NON-FUSED DISCONNECT SWITCH

DISCONNECT SWITCH W/ AMP FRAM AND AMP FUSE

MOLDED CASE CIRCUIT BREAKER

GROUND FAULT CIRCUIT BREAKER

NON-FUSED SWITCH

FUSED SWITCH

FUSE

TRANSFORMER

TRANSFORMER (DELTA TO GROUND WYE)

XXXX

XXXX

M

X

XXXA3P

G

NO SCALE

NOTES:1. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX

UNLESS OTHERWISE NOTED.2. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS

SHALL GOVERN OVER THOSE SHOWN ABOVE.3. CONTRACTOR SHALL ENSURE THAT MOUNTING HEIGHTS COMPLY

WITH CURRENT ADA REQUIREMENTS.4. WHEREVER DEVICES ARE INDICATED TO BE ABOVE

DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OFDOOR TRIM AND CEILING LINE.

5. ALL ABOVE COUNTER (DESIGNATED BY "AC") DEVICES SHALL BEMOUNTED 8" ABOVE COUNTER TO OR A MAXIMUM HEIGHT OF 44"(3'-8") TO TOP OF DEVICE. VERIFY HEIGHTS WITH ARCHITECT.

TYPICAL DEVICE MOUNTING HEIGHTS

TYPICAL 9'-0" CEILING OR HIGHER

TYPICAL 8'-0" CEILING

TOP OF CABINET

TOP OF CABINET

TOP OF CABINET

TV

TV

FACP

FAAP

CONTROL PANELS

(WALL PHONES)

(SINGLE ORGANGED,ALL TYPES)

FINISHED FLOOR

18"

(1'-6")

UO

N

46"

(3'-10")

UO

N

54"

(4'-6")

UO

N

64"

(5'-4")

UO

N

72"

(6'-0")

UO

N

78"

(6'-6")

UO

N

84"

(7'-0")

UO

N

96"

(8'-0")

UO

N

82"

(6'-10")

OR

6"

BE

LO

W C

EIL

ING

,W

HIC

HE

VE

R IS

LO

WE

R

M

NOTE: ALL DEVICES INDICATEDTO BE INSTALLED AT DIFFERENTMOUNTING HEIGHTS AND LOCATEDWITHIN ONE STUD SPACE FROMEACH OTHER SHALL ALIGNVERTICALLY, ON THE SAME SIDEOF THE STUD. WHERE WALLMOUNTED TELEPHONES OCCUR OVERLIGHT SWITCHES, VOLUME CONTROLS,ETC. OFFSET ONE STUD SPACE.

SHADED SYMBOLS DENOTE EMERGENCY FIXTURES

SINGLE-PHASE BRANCH CIRCUIT CONDUCTOR SIZING

120V CIRCUITS:

CIRCUIT LENGTH (2)0-75 FT76-125 FT126-190 FT191-300 FT

WIRE SIZE#12#10#8#6 (1)

208V/240V/277V CIRCUITS:

CIRCUIT LENGTH (2)0-125 FT126-215 FT216-330 FT

WIRE SIZE#12#10#8

NOTES:(1) FOR TERMINATING IN PANELBOARDS, PROVIDE A UL846A/B LISTED, HYDRAULICALLY-APPLIED COMPRESSION PIN ADAPTER TERMINAL WITH INSULATED COVER THAT IS DESIGNED FOR #6 AWG COPPER CONDUCTOR TO #8 PIN SIZE.

(2) CIRCUIT LENGTH IS MEASURED ONE-WAY TO THE THEORETICAL CENTER OF THE ELECTRICAL LOAD.

(3) CALCULATIONS ARE BASED ON A 4.0% VOLTAGE DROP FOR A 16A LOAD WITH UNITY POWER FACTOR.

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

9:2

5 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

ELECTRICALLEGEND

E0.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

7/15/2020

Page 24: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

SECTION 260000 - ELECTRICAL

PART 1 - GENERAL

1.01 CONFORM TO ALL APPLICABLE STATE, COUNTY AND MUNICIPAL

CODES AND ORDINANCES AND NEMA, UL, ANSI AND CBM

STANDARDS. WHERE A PROVISION OF PERTINENT CODES AND

STANDARDS CONFLICT WITH THIS SPECIFICATION, THE MORE

STRINGENT PROVISIONS SHALL GOVERN.

1.02 APPLY AND PAY FOR ALL PERMITS AND/OR INSPECTIONS REQUIRED

BY LEGAL AUTHORITIES.

1.03 COORDINATE ELECTRICAL WORK, AND EXISTING SYSTEM

SHUTDOWNS WITH THE OWNER. NOTIFY THE OWNER OF PLANNED

SHUTDOWNS A MINIMUM OF TWO (2) DAYS PRIOR TO

COMMENCEMENT OF THE WORK, INCLUDING INFORMATION OF TYPE

OF SERVICE, PLANNED TIME AND ANTICIPATED LENGTH OF OUTAGE.

1.04 PRIOR TO SUBMITTING BID, SURVEY THE AREA WHERE THE NEW

WORK WILL BE DONE FOR ANY EXISTING CONDITIONS WHICH MAY

AFFECT OR BE AFFECTED BY THE WORK UNDER THIS SECTION.

EXAMINE THE DRAWINGS AND SPECIFICATIONS OF ALL TRADES TO

ESTABLISH THE SCOPE OF WORK TO BE PROVIDED UNDER THIS

SECTION. LIST ANY EXCEPTIONS TO THE CONTRACT DOCUMENTS

AND SUBMIT WITH BID.

1.05 EXERCISE EXTREME CARE TO INSURE PROTECTION OF EXISTING

ELECTRICAL EQUIPMENT AND PREMISES FROM DAMAGE. ASSUME

COMPLETE RESPONSIBILITY FOR ANY AND ALL DAMAGE RESULTING

FROM THIS WORK.

1.06 EXERCISE CARE TO PREVENT THE GENERATION OF UNNECESSARY

NOISE DURING THE WORK, AND KEEP NOISE LEVELS TO THE

MINIMUM POSSIBLE.

1.07 PROVIDE BID BASED ON SPECIFIED MATERIAL AND EQUIPMENT.

SUBSTITUTIONS OF SPECIFIED MATERIALS AND EQUIPMENT ARE

SUBJECT TO THE APPROVAL OF THE ENGINEER.

1.08 PROVIDE SHOP DRAWINGS AND MANUFACTURER'S DATA, FOR

LIGHTING FIXTURES, RECEPTACLES, OUTLETS, CONDUCTORS AND

CONDUITS.

1.09 GUARDING

A. PROVIDE PROTECTION FOR MOVING PARTS AND HAZARDOUS

CONDITIONS.

B. PROVIDE INDUSTRIAL ACCIDENT AND WARNING SIGNS PER ANSI AND

OSHA.

C. ERECT AND MAINTAIN SUITABLE BARRIERS, PROTECTIVE DEVICES,

LIGHTS AND WARNING SIGNS FOR THE PROTECTION OF THE PUBLIC

AND EMPLOYEES FROM THE WORK UNDER THIS SECTION.

D. CONFORM WITH APPLICABLE SAFETY REGULATIONS, INCLUDING

THOSE OF THE ENGINEER AND OWNER.

1.10 MANUFACTURER'S NAMES, PRODUCTS AND NUMBERS LISTED ON THE

DRAWINGS OR IN THESE SPECIFICATIONS, ALONG WITH SPECIFIC

DESCRIPTIONS IN THESE SPECIFICATIONS, SET THE STANDARD OF

QUALITY AND PERFORMANCE. SELECT PRODUCTS OF ONE OF THE

LISTED MANUFACTURERS MEETING THESE STANDARDS AND MODIFY

STANDARD CATALOG ITEMS WHERE REQUIRED TO MEET

SPECIFICATIONS. THE PHRASE "OR EQUAL BY" FOLLOWED BY

MANUFACTURER'S NAMES MEANS, THAT THIS MANUFACTURER'S

PRODUCT SHALL MATCH THE PERFORMANCE, CONSTRUCTION, FIT

AND FEATURES SPECIFIED.

1.11 AT THE CONCLUSION OF THE WORK, PROVIDE A SET OF RECORD

REPRODUCIBLE ELECTRICAL CONTRACT DRAWINGS, SIGNED AND

DATED, INDICATING THE ACTUAL INSTALLATION OF THE ELECTRICAL

WORK INCLUDING ALL REVISIONS, BULLETINS AND CHANGE ORDERS.

1.12 GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR FROM THE DATE

OF WRITTEN ACCEPTANCE OF THE WORK BY THE OWNER.

PART 2 - PRODUCTS

2.01 GENERAL

A. PROVIDE MATERIAL AND EQUIPMENT OF NEW AND RECENT

MANUFACTURE, CURRENTLY UL LABELED AND/OR LISTED FOR THE

SPECIFIED USE.

B. WHERE UL LABELING IS NOT AVAILABLE, PROVIDE CERTIFICATION BY

A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL).

C. FOR EACH CATEGORY OF MATERIAL AND EQUIPMENT, USE

PRODUCTS OF THE SAME MANUFACTURE AND TYPE.

2.02 CONDUCTORS - 600V

A. GENERAL:

1. PROVIDE CONDUCTORS SUITABLE FOR THE TEMPERATURE,

CONDITIONS, AND LOCATION WHERE INSTALLED. ALL CONDUCTORS

SHALL BE NEW AND DELIVERED TO THE SITE IN ORIGINAL UNBROKEN

PACKAGES OR REELS. MANUFACTURED WITHIN EIGHT (8) MONTHS OF

INSTALLATION, OF SOFT DRAWN COPPER OF NOT LESS THAN 98

PERCENT CONDUCTIVITY, 75 DEGREE CELSIUS TEMPERATURE

RATING, CONFORMING WITH ASTM SPECIFICATION AND NEC; 600V

INSULATION UNLESS SPECIFICALLY NOTED OTHERWISE, OF THE

TYPE SPECIFIED, STANDARD AMERICAN WIRE GAUGE (AWG) SIZES;

SOLID FOR NO. 10 AWG AND SMALLER; STRANDED FOR NO. 8 AWG

AND LARGER.

2. ALL PACKAGES, PLAINLY MARKED OR TAGGED WITH UNDERWRITERS'

LABELS; SIZE, TYPE, INSULATION AND VOLTAGE RATING OF THE

WIRE; NAME OF MANUFACTURING COMPANY AND THE TRADE NAME

OF THE WIRE; DATE OF MANUFACTURE.

B. CONDUCTOR MATERIAL: ALL CONDUCTORS SHALL BE COPPER, SINGLE

CONDUCTOR RATED AT 600 VOLTS, WHICH CONFORM OR EXCEED

ICEA SPECIFICATIONS AND THE FOLLOWING CONDUCTOR

INSULATION:

1. SIZES NO. 1 AND LARGER: XHHW-2, 75 C RATED.

2. NO. 2 AWG AND SMALLER: THWN, XHHW-2.

3. FOR DRY LOCATIONS: THWN.

C. MC (METAL CLAD) CABLE: USE ONLY FROM OVERHEAD JUNCTION

BOXES DOWN THE WALL TO ELECTRICAL OUTLETS. DO NOT USE FOR

HOMERUNS, RUNS TO LIGHT SWITCHES, CONNECTING DEVICES FROM

ADJACENT OR OPPOSITE WALLS, AND CONNECTING DEVICES IN SEPARATE

ROOMS. A CONDUIT AND JUNCTION BOX “BACKBONE” SYSTEM SHALL BE

INSTALLED THROUGHOUT THE BUILDING. MC CABLE IS TO ONLY BE

UTILIZED DOWN THE WALL FROM THE OVERHEAD JUNCTION BOX LOCATED

IN THE ROOM IT'S SERVICING. MC CABLE ALSO SERVING OUTLETS IN

ADJACENT ROOMS IS NOT ACCEPTABLE, I.E. BACK TO BACK OUTLETS.

PROPER FACTORY APPLIED CONDUCTOR COLOR-CODING SHALL BE

FOLLOWED, TAPING OF CONDUCTORS IS NOT ACCEPTABLE. MC CABLE

SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS AND STANDARDS:

1. UL 83, 1479, 1569, AND NEC 230 AND 300.

2. GALVANIZED STEEL ARMOR.

3. 2, 3, AND 4 CONDUCTORS, #12 AND #10 THHN SOLID COPPER.

4. MYLAR TAPE COVERING FOR CONDUCTOR ASSEMBLY.

5. 90°C MAXIMUM TEMPERATURE RATING, DRY LOCATIONS

6. INSULATED GREEN GROUNDING CONDUCTOR.

7. MAXIMUM 600V RATING

8. WHERE INDICATED ON THE DRAWINGS, PROVIDE #10 NEUTRAL

CONDUCTOR COMBINED WITH THE #12 PHASE CONDUCTORS IN THE

CABLE ASSEMBLY.

2.03 RACEWAYS

A. RIGID STEEL CONDUIT: ANSI C80.1: RIGID CONDUIT INCLUDING

COUPLINGS, LOCKNUTS, NIPPLES: STEEL, HOT-DIPPED GALVANIZED

INSIDE AND OUT AFTER THREADING, GALVANIZED, THREADED

MALLEABLE IRON OR STEEL FITTINGS, NOTCHED LOCKNUTS WITH

GRIPPING TEETH. DELIVER WITH PLASTIC THREAD PROTECTORS ON

EXPOSED CONDUIT THREADS.

B. INTERMEDIATE STEEL CONDUIT: UL 1242: INTERMEDIATE METAL

CONDUIT INCLUDING COUPLINGS, LOCKNUTS, NIPPLES: STEEL, HOT

PROCESS GALVANIZED OUTSIDE, LACQUERED OR ENAMELED INSIDE,

GALVANIZED THREADS, GALVANIZED THREADED MALLEABLE IRON OR

STEEL FITTINGS, NOTCHED LOCKNUTS WITH GRIPPING TEETH.

DELIVER WITH PLASTIC THREAD PROTECTORS ON EXPOSED

CONDUIT THREADS.

C. ELECTRICAL METALLIC TUBING AND FITTINGS: ANSI C80.3: ELECTRIC

METALLIC TUBING (EMT) INCLUDING LOCKNUTS, COUPLINGS AND

CONNECTORS: GALVANIZED STEEL, LACQUERED OR ENAMELED

INTERIOR; RAINTIGHT GLAND RING COMPRESSION TYPE FITTINGS

AND SETSCREW FITTINGS, INSULATED THROAT CONNECTORS.

D. FLEXIBLE METAL CONDUIT: UL 1, ZINC-COATED STEEL: FLEXIBLE

CONDUIT: MANUFACTURED FROM SINGLE STEEL STRIP, GALVANIZED

ON ALL FOUR SIDES PRIOR TO FABRICATION, DIE CAST TWIST-IN

CONNECTORS, UL LISTED FOR GROUND CONTINUITY. ALUMINUM OR

REDUCED WALL FLEXIBLE CONDUIT IS NOT ACCEPTABLE.

E. LIQUIDTIGHT FLEXIBLE CONDUIT AND FITTINGS: UL 360: LIQUIDTIGHT

FLEXIBLE CONDUIT: FLEXIBLE GALVANIZED STEEL CORE, WITH

EXTRUDED POLYVINYL CHLORIDE COVER. LIQUIDTIGHT INSULATED

THROAT FITTINGS TO SEAL AND GROUND CONDUIT. PROVIDE

SEPARATE BOND WIRE WHERE INTEGRAL GROUND CONDUCTOR IS

NOT AVAILABLE.

2.04 OUTLET AND JUNCTION BOXES AND FITTINGS.

A. PROVIDE BRIGHT AND NEW STOCK, STORED WHERE CONTINUOUSLY

PROTECTED FROM WEATHER AND CONFORMING TO THE FOLLOWING:

1. OUTLET BOXES AND COVERS: STEEL, KNOCKOUT TYPE, WITH FULL

ACCESS SCREW-ON COVERS OR PLASTER RINGS, HOT-DIPPED,

GALVANIZED, WITH CADMIUM PLATED OR GALVANIZED MACHINE

SCREWS.

2. CAST OUTLET BOXES: CAST FERROUS METAL CONSTRUCTION,

GALVANIZED, COMPLETE WITH THREADED HUBS FOR RIGID CONDUIT,

NUMBER AND LOCATION AS REQUIRED, AND PLUGS IN UNUSED HUBS;

CAST DEVICE PLATES SUITABLE FOR INDICATED DEVICE; MEETING

NEC REQUIREMENTS FOR BENDING AND PERMITTED NUMBER OF

CONDUCTORS; EDGES WELDED AND GROUND SMOOTH, LEAVING

INTERIOR FILLETS; GALVANIZED AFTER FABRICATION; GASKETED

COVERS; STAINLESS STEEL SCREWS; FACTORY PAINTED WITH GRAY

ENAMEL. GASKETS TO BE FACTORY MADE OR AN APPROVED TYPE. IN

HAZARDOUS AREA, APPROVED FOR THE CLASS OF HAZARD. FOR

CLASS "1", DIVISION "1", GROUP B HAZARD CLASSIFICATION UNLESS

OTHERWISE NOTED.

3. JUNCTION OR PULL BOXES:

a. CODE GAUGE SHEET STEEL CONSTRUCTION, RUST RESISTANT ZINC

COATING, WITH FULL ACCESS SCREWED ON COVERS AND CADMIUM

PLATED OR GALVANIZED MACHINE SCREWS, MINIMUM SIZE PER THE

GOVERNING ELECTRICAL CODE OR AS NOTED ON THE DRAWINGS,

WHICHEVER IS GREATER; BARRIERS FOR REQUIRED SEPARATION;

SPECIAL CONFIGURATION, WHERE DETERMINED FROM FIELD

MEASUREMENTS TO SURMOUNT STRUCTURAL CONDITIONS. FOR

FLUSH MOUNTING, EXTEND COVERS 3/4" BEYOND EDGE OF BOXES.

WHERE USED FOR CABLE SUPPORT, BRACE BOX TO SUPPORT CABLE

WEIGHT. FOR JUNCTION BOXES LARGER THAN 36" IN ANY DIMENSION,

PROVIDE 3/4" DIAMETER STEEL PIPE CABLE SUPPORTS WITH

FLANGED ENDS WITH CONTINUOUS FIBER INSULATING SLEEVE AND

BOLTED TO BOX FRAME, SPACED ON 36" CENTERS MAXIMUM. FOR

COVER DIMENSIONS 3'x4' OR LARGER, PROVIDE TWO PIECE COVERS

EQUIPPED WITH HANDLES.

b. FACTORY FINISH: WASH AND PHOSPHATE UNDERCOAT. ANSI 49 GRAY

ENAMEL PAINT FOR NEMA 1, ANSI 61 GRAY POLYESTER POWDER

FINISH FOR NEMA 3R AND 12. KNOCKOUT CLOSURES AND LOCKNUTS;

PROVIDE CORROSION-RESISTANT BOX KNOCKOUT CLOSURES,

CONDUIT LOCKNUTS, OFFSET CONNECTORS, OF TYPES AND SIZES,

TO SUIT RESPECTIVE INSTALLATION REQUIREMENTS AND

APPLICATIONS.

2.05 WIRING DEVICES

A. GENERAL:

1. SPECIFICATION GRADE DEVICES.

2. GENERAL USE: IVORY COLOR (AS AVAILABLE) UNLESS OTHERWISE

NOTED OR SPECIFIED.

3. SCREW TYPE TERMINALS ON DEVICES, SUITABLE FOR UP TO NO. 10

SOLID COPPER CONDUCTORS.

4. WHERE NOT SPECIFIED HEREIN, PROVIDE CONFIGURATION AS

INDICATED ON DRAWINGS.

B. RECEPTACLES: SHALL COMPLY WITH UL 498 AND NEMA WD1 AND

WD5.

1. GENERAL: NUMBER OF POLES AND AMPERE RATING AS SHOWN ON

DRAWINGS AND OF NEMA STANDARD CONFIGURATIONS. GROUND

POLE CONNECTED TO CIRCUIT GROUNDING CONDUCTOR.

2. DUPLEX CONVENIENCE RECEPTACLES: 20A, 125V; GROUNDING

THIRD POLE; SIDE-WIRED FOR 2 WIRE CIRCUIT USE. WHERE 2

CIRCUITS ARE INDICATED, PROVIDE INDIVIDUAL CIRCUIT FOR EACH

HALF. NEMA 5-20R.

3. GROUND FAULT INTERRUPTING (GFI) RECEPTACLES: NEMA 5-20R

DUPLEX RECEPTACLE WITH INTEGRAL GROUND FAULT PROTECTION.

4. WEATHERPROOF RECEPTACLES: NEMA 5-20R DUPLEX GFI

RECEPTACLE MOUNTED IN CAST BOX, STUB MOUNTED, WITH

GASKETED LIFT COVER. PROVIDE PLUGGED HUBS IN BOX SIDES FOR

EXTENSION.

C. TOGGLE SWITCHES:

1. FLUSH TUMBLER, AC TYPE, INSULATED BASE, COMPLETELY

ENCLOSED.

2. 20A, TUNGSTEN LOAD RATED, AT 277V.

3. 1 POLE, 2 POLE, 3-WAY, 4-WAY OR KEY OPERATED AS INDICATED ON

DRAWINGS. 2 POLE UNIT USEABLE FOR (2) 120V CIRCUITS OR (1) 277V

CIRCUIT ONLY. DO NOT USE FOR TWO 277V CIRCUITS.

D. WALL PLATES: SINGLE AND COMBINATION, OF TYPES, SIZES, AND

WITH GANGING AND CUTOUTS AS INDICATED. PROVIDE METAL

SCREWS FOR SECURING PLATES TO DEVICES WITH SCREW HEADS

COLORED TO MATCH FINISH OF PLATES. PROVIDE WALL PLATES

WITH LEGEND AS SPECIFIED, OR WHERE INDICATED ON DRAWINGS.

ALL LETTERING SHALL BE BLACK FOR NORMAL POWER SYSTEMS AND

RED FOR EMERGENCY POWER SYSTEMS. PROVIDE PLATES

POSSESSING THE FOLLOWING ADDITIONAL CONSTRUCTION

FEATURES:

1. DEVICE PLATES OF ONE MAKE AND DESIGN FOR ALL OUTLETS,

SMOOTH, SATIN FINISH, TYPE 302, STAINLESS STEEL, 0.035" THICK,

BEVELED EDGES, TO FIT DEVICE.

2. FOR EXTERIOR LOCATIONS: PROVIDE METALLIC COVER, THE TYPE OF

WEATHERPROOF COVER THAT MAINTAINS THE WEATHERPROOF

INTEGRITY WHILE THE OUTLET IS IN USE.

2.06 CIRCUIT AND MOTOR DISCONNECT SWITCHES

A. HEAVY DUTY (HD) HORSEPOWER RATED, QUICK-MAKE, QUICK-BREAK,

SAFETY TYPE, EXTERNALLY OPERATED, RATING AND NUMBER OF

POLES REQUIRED, CAPABLE OF SWITCHING 10 TIMES SWITCH

RATING. FUSED FOR BRANCH CIRCUIT PROTECTION, AND IN

ELEVATOR MACHINE ROOMS, WITH UL REJECTION TYPE CLIPS.

NON-FUSED FOR MOTOR DISCONNECT WHERE INDICATED. SWITCH

AND ENCLOSURE TO BE LABELED FOR 75 DEGREE CELSIUS WIRE.

B. INCLUDE BYPASSIBLE INTERLOCK, PADLOCK PROVISIONS, POSITIVE

ON AND OFF INDICATION, MOLDED CASE BREAKER MECHANISM OR

VISIBLE BLADES, SINGLE SWITCH MECHANISM TO PRECLUDE

MECHANICAL SINGLE PHASING, SOLID NEUTRAL BAR FOR FOUR

WIRE FEEDERS, COPPER TERMINALS, SPRING LOADED CLIPS WITH

NON-CURRENT CARRYING SPRINGS.

C. ENCLOSURES TO BE NEMA TYPE 1 IN INTERIOR DRY LOCATIONS,

NEMA TYPE 3R ON EXTERIOR AND IN WET LOCATIONS, NEMA TYPE

4X IN CORROSIVE LOCATIONS.

D. USE MANUAL MOTOR STARTING SWITCHES FOR MANUAL CONTROL

AND/OR DISCONNECTING OF 120V FRACTIONAL MOTORS AND FOR

DISCONNECTING OF 3 PHASE MOTORS UP TO 5 HP AT 230V AND 10

HP AT 480V. FLUSH MOUNTED IN FINISHED AREAS. NEMA 1

ENCLOSURE ON INTERIOR, NEMA 3R ON EXTERIOR.

2.07 MANUAL MOTOR STARTERS

A. VOLTAGE AS REQUIRED, HORSEPOWER RATED, PADLOCKABLE,

TOGGLE OPERATED, WITH POLE AND BIMETALLIC OVERLOAD HEATER

FOR EACH UNDERGROUND LEG, ON, OFF AND TRIPPED INDICATION,

INTEGRAL RUNNING PILOT LIGHT, FLUSH MOUNTED WHERE

PRACTICAL.

B. WHERE USED FOR MOTOR DISCONNECT SWITCH OMIT OVERLOADS

AND PILOT LIGHT.

2.08 LIGHTING FIXTURES, GENERAL

A. PROVIDE A COMPLETE LIGHTING SYSTEM, WIRED, ASSEMBLED AND

OPERABLE, INCLUDING LIGHTING EQUIPMENT AND ACCESSORIES AS

SHOWN ON THE DRAWINGS, DESCRIBED IN THE FIXTURE SCHEDULE,

SPECIFIED HEREIN AND COVERED BY ALLOWANCE. ACCESSORIES

INCLUDE CANOPIES, SUSPENSION OF PROPER LENGTHS, HICKEYS,

CASTINGS, SOCKETS, HOLDERS, REFLECTORS, BALLASTS, DIFFUSING

MATERIAL, LOUVERS, PLASTER AND MOUNTING FRAMES, LAMPS,

RECESSING BOXES, SUPPORTING BRACKETS AND CHANNELS,

WHERE REQUIRED TO SPAN STRUCTURAL MEMBERS.

B. FIXTURES TO BE FACTORY PREWIRED AND PREASSEMBLED.

CATALOG NUMBERS OR SERIES ARE GIVEN FOR MANUFACTURER'S

IDENTIFICATION. CONFORM TO WRITTEN DESCRIPTIVE

REQUIREMENTS GOVERNING MATERIAL AND FABRICATION, EITHER IN

THE GENERAL OR SPECIFIC SECTIONS. WHERE CATALOG NUMBERS

ARE INDICATED AS MODIFIED, NO MODIFICATION WILL BE REQUIRED

IF THE STANDARD UNIT FULLY CONFORMS TO ALL DESCRIPTIVE

REQUIREMENTS IN THE SPECIFICATIONS AND CONFORMS WITH

SPECIFIED CEILING CONSTRUCTION.

C. FOR RECESSED FIXTURES, PROVIDE FRAME AND TRIM COMPATIBLE

WITH CEILING TYPE AND CONSTRUCTION. REFER TO CEILING

SPECIFICATIONS AND ARCHITECTURAL DRAWINGS TO DETERMINE

TYPES.

D. PROVIDE ADEQUATE LAMP SHIELDING, PROPER VENTILATION AND

HEAT DISSIPATION.

E. SECURE DIFFUSERS TO TRIM BY DEVICES NOT REQUIRING TOOLS

FOR REMOVAL, OR FOR RELAMPING. PROVIDE SAFETY CHAIN

ATTACHMENT TO FIXTURE HOUSING FOR PORTIONS OF FIXTURES

WHICH ARE REMOVED FOR SERVICING OR RELAMPING.

F. GENERAL CONSTRUCTION:

1. SHEET METAL: FREE OF TOOL MARKS AND DENTS. PAINTED AFTER

PUNCHING AND FORMING TO ELIMINATE EXPOSED UNPAINTED

EDGES. INTERSECTIONS AND JOINTS FORMED TRUE, SUFFICIENTLY

RIGID TO PREVENT DISTORTION AFTER ASSEMBLY.

2. CASTINGS: FREE OF BLEMISHES, SCALE AND RUST, AND FINISHED

SMOOTH.

3. ALUMINUM SURFACES, NONREFLECTING: ANODIZED CLEAR OR WITH

COLOR AS INDICATED. CASTINGS TO BE IRRADIATED, SANDBLASTED

OR ANODIZED.

4. ALUMINUM REFLECTORS: TREAT WITH ALZAK PROCESS TO PROVIDE

PERMANENT REFLECTIVE SURFACE OF 85% MINIMUM. EXTRUDED

REFLECTORS TO BE UNSCORED, BRIGHT DIPPED AND CLEAR

ANODIZED.

G. LIGHTING FIXTURE DESCRIPTION: REFER TO THE SCHEDULE ON THE

DRAWINGS, OR IN THE SPECIFICATIONS, AND TO GENERAL

REQUIREMENTS IN OTHER PARAGRAPHS HEREIN FOR FULL FIXTURE

DESCRIPTION.

H. FOR RECESSED FIXTURES, PROVIDE MOUNTING FRAME WITH AN

ATTACHED PREWIRED JUNCTION BOX, RATED FOR THROUGH WIRING

WITH 60 DEGREE CELSIUS CONDUCTORS, DESIGNED FOR

INSTALLATION WITHOUT INSTALLING TRIM, DIFFUSERS OR LENS.

VERIFY SUITABILITY OF ATTACHED JUNCTION BOXES FOR NUMBER

OF CONDUCTORS INDICATED ON DRAWINGS, AND PROVIDE

ADDITIONAL BOXES WHERE ATTACHED JUNCTION BOX CAPACITY IS

EXCEEDED.

I. PROVIDE SPECIFIC UL LABEL FOR USE AND MOUNTING.

LABEL USE

IC INSULATED CEILINGS

NON IC (WITH THERMAL OVERLOAD) FIXED CEILINGS

SC SUSPENDED ACCESSIBLE CEILING

PC CONCRETE POUR CEILING

DAMP LOCATION EXTERIOR PROTECTED LOCATIONS

WET LOCATION EXTERIOR EXPOSED LOCATIONS

J. FASTEN OR HINGE TRIMS AND LENSES TO THE FIXTURE BODY SO

THAT NO PART OF THE FIXTURE MUST BE HELD DURING THE

RELAMPING PROCEDURE. SECURELY RETAIN LENSES IN LENS DOOR

SO THAT DROPPING OF DOOR CANNOT DISLODGE LENS

K. GLASS LENSES OR DIFFUSERS TO BE FREE FROM SPHERICAL OR

CHROMATIC IMPERFECTIONS AND HAVE THERMAL CHARACTERISTICS

OF PYREX.

2.09 PANELBOARDS

A. GENERAL FEATURES:

1. CODE GAUGE, SHEET STEEL CABINETS, RUST RESISTANT ZINC

COATING WITH CORNERS LAPPED AND WELDED OR RIVETED, DEAD

FRONT, DEAD REAR, FRONT ACCESSIBLE.

2. FULL HEIGHT UNREDUCED COPPER BUS, RIGIDLY SUPPORTED.

SOLDERLESS, BOLTED PRESSURE BAR TYPE, COPPER LUGS FOR

CONNECTION. BUS FEEDER SEQUENCE AS FOR SWITCHBOARDS.

SOLID COPPER NEUTRAL BAR FOR GROUNDED SYSTEMS. LUGS

SIZED FOR FEEDERS. SUB-BREAKERS, SPLIT BUS, MAIN LUGS, MAIN

BREAKER, DOUBLE LUGS, VOLTAGE AND CURRENT RATINGS, ALL AS

INDICATED ON THE DRAWINGS.

3. MAIN BREAKERS, COMMON TRIP, SINGLE HANDLE, MOUNTED

VERTICALLY AHEAD OF PANEL BUS.

4. COPPER EQUIPMENT GROUND BUS FOR TERMINATION OF FEEDER

AND BRANCH CIRCUIT GROUNDING CONDUCTORS.

5. HINGED LOCKABLE DOOR COVERING ALL DEVICES. FLUSH CATCH

AND CYLINDER LOCK. VAULT HANDLE ON DOORS OVER 4' HIGH. ALL

PANELS AND CABINETS KEYED ALIKE. PROVIDE TWO KEYS PER

PANEL AND CABINET. FOR NEW PANELBOARDS IN EXISTING

FACILITIES, MATCH KEYS AND LOCKS TO EXISTING PANELBOARDS.

6. CERTIFY CONFORMANCE WITH THE SPECIFICATIONS.

B. BRANCH CIRCUIT PANELBOARDS ADDITIONAL FEATURES:

1. MINIMUM SIZE 20" WIDE, BY 5-3/4" DEEP, UNLESS SPECIFICALLY

INDICATED OTHERWISE.

2. INDEX CARDHOLDER ON INSIDE OF DOOR WITH TYPEWRITTEN

CIRCUIT SCHEDULES REFLECTING AS-BUILT CIRCUITING, BEHIND

CLEAR PLASTIC COVER IN METAL FRAME.

3. AUTOMATIC CIRCUIT BREAKERS, 1" WIDE NOMINAL, MOLDED CASE,

TRIP FREE, QUICK-MAKE, QUICK-BREAK, THERMAL MAGNETIC TYPE,

BOLTED TO THE BUS, WITH HANDLES CLEARLY INDICATING SIZE AND

TRIPPED POSITION, OF SIZE AND ARRANGEMENT AS SHOWN ON

SCHEDULES. COMMON INTERNAL TRIP FOR MULTI-POLE BREAKERS.

PERMANENT FACTORY INSTALLED METAL CIRCUIT NUMBERS ON

ADJACENT TRIM (INCLUDING SPACES), SCREWED OR RIVETED TO

TRIM. ADHESIVELY APPLIED LABELS ARE NOT ACCEPTABLE.

PART 3 - EXECUTION

3.01 SITE CONDITIONS

A. EXAMINE THE DRAWINGS OF ALL TRADES, AND SPECIFICATION

SECTIONS, SURVEY THE EXISTING CONDITIONS, AND INCLUDE

NECESSARY ALLOWANCES IN BID PROPOSAL.

B. RESOLVE ALL CONFLICTS WITH CODE REQUIREMENTS, SITE

CONDITIONS AND THE WORK OF OTHER TRADES.

C. VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO

CONSTRUCTION AND PROTECT THEM FROM DAMAGE.

D. PAY COSTS INCURRED DUE TO DAMAGE OF EXISTING UTILITIES OR

OTHER FACILITIES.

3.02 LOCATIONS

A. DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC, AND ALTHOUGH THE

SIZE AND LOCATIONS OF EQUIPMENT ARE GENERALLY SHOWN TO

SCALE, MAKE USE OF DATA IN CONTRACT DOCUMENTS, AND

INFORMATIONAL DOCUMENTS, INCLUDING SHOP DRAWINGS, AND

VERIFY THIS INFORMATION AGAINST FIELD CONDITIONS.

B. DRAWINGS INDICATE THE REQUIRED SIZE AND POINTS OF

TERMINATION OF CONDUITS, AND THE NUMBER AND SIZE OF WIRES

AND SUGGEST PROPER ROUTING OF CONDUIT. INSTALL CONDUIT

WITH ALL NECESSARY OFFSETS, JUNCTION BOXES, AND FITTINGS TO

CONFORM TO THE STRUCTURE, AVOID OBSTRUCTIONS, PRESERVE

HEADROOM, MAINTAIN REQUIRED ACCESSIBILITY, AND SATISFY THE

REQUIREMENTS OF THE GOVERNING CODES AND THE STANDARDS

OF GOOD PRACTICE.

C. WHEN CHANGES IN INDICATED LOCATIONS OR ARRANGEMENTS ARE

NECESSARY DUE TO CONDITIONS IN BUILDING CONSTRUCTION,

REARRANGEMENT OF FURNISHINGS OR EQUIPMENT, OR CONFLICT IN

LOCATION, MAKE SUCH CHANGES AT NO COST TO OWNER,

PROVIDED THAT THE CHANGE IS ORDERED BEFORE CONDUIT IS

INSTALLED AND THAT LENGTH OF CONDUIT RUN IS NOT REVISED BY

MORE THAN TEN FEET.

D. BRING DISCREPANCIES BETWEEN DIFFERENT DRAWINGS, BETWEEN

DRAWINGS AND ACTUAL FIELD CONDITIONS, OR BETWEEN

DRAWINGS AND SPECIFICATIONS, PROMPTLY TO THE ATTENTION OF

THE ARCHITECT OR ENGINEER FOR DECISION, AND STOP PERTINENT

WORK SUBJECT TO RESOLUTION OF THE CONFLICT.

E. COORDINATE THE LOCATION OF THE LIGHTING FIXTURES AND

FRAMING WITH THE CEILING CONSTRUCTION SO THAT THE OVERALL

PATTERN IS ACCEPTABLE TO THE ARCHITECT. ARCHITECTURAL

REFLECTED CEILING DRAWINGS, PLANS AND DETAILS GOVERN.

F. PROVIDE CLARIFYING DETAILS WHERE REQUIRED BY INSPECTING

AUTHORITY AND OBTAIN ARCHITECT'S AND INSPECTOR'S APPROVAL

PRIOR TO INSTALLATION.

3.03 RESPONSIBILITY

A. PROVIDE COMPLETE FUNCTIONING SYSTEMS AND INCLUDE LABOR,

MATERIAL AND ASSOCIATED TOOLS AND TRANSPORTATION

REQUIRED FOR THE SYSTEM TO OPERATE SAFELY AND

SATISFACTORILY. PROVIDE EMPTY CONDUIT SYSTEMS WHERE

SPECIFIED, COMPLETE, CLEAR, AND WITH PULL WIRES, READY TO

ACCEPT CONDUCTORS AND ALLOW FOR EQUIPMENT INSTALLATION.

B. PROVIDE WORK INDICATED ON THE DRAWINGS WHETHER OR NOT

SPECIFICALLY MENTIONED IN THE SPECIFICATIONS.

C. COORDINATE THE INSTALLATION OF ELECTRICAL ITEMS WITH THE

SCHEDULES FOR WORK OF OTHER TRADES TO PREVENT DELAYS IN

TOTAL WORK. ASSUME RESPONSIBILITY FOR COOPERATIVE WORK,

WHICH MUST BE ALTERED DUE TO LACK OF PROPER SUPERVISION

OR FAILURE TO MAKE PROPER PROVISION IN TIME. PERFORM

ALTERATIONS TO ARCHITECT'S SATISFACTION, AND PAY COSTS.

D. RESOLVE CODE CONFLICTS PRIOR TO INSTALLATION. REMOVE AND

REPLACE WORK CONFLICTING WITH CODES OR, IN THE ARCHITECT'S

OPINION, NOT MEETING SPECIFIED REQUIREMENTS AND PAY COSTS.

3.04 QUALITY ASSURANCE

A. PROVIDE AN EXPERIENCED SUPERINTENDENT IN CHARGE OF

ERECTION OF THE WORK, TOGETHER WITH ALL NECESSARY

JOURNEYMEN, HELPERS AND LABORERS REQUIRED TO PROPERLY

UNLOAD, ERECT, CONNECT, ADJUST, OPERATE AND TEST THE WORK

INVOLVED TO PRODUCE A NEAT, WORKMANLIKE INSTALLATION.

LATEST INDUSTRY STANDARDS ARE CONSIDERED MINIMUM.

B. FOR THE ACTUAL FABRICATION, INSTALLATION, AND TESTING OF THE

WORK OF THIS SECTION USE ONLY THOROUGHLY TRAINED AND

EXPERIENCED PERSONNEL WHO ARE COMPLETELY FAMILIAR WITH

THE REQUIREMENTS FOR THIS WORK AND WITH THE INSTALLATION

RECOMMENDATIONS OF THE MANUFACTURERS OF THE SPECIFIED

ITEMS. WHERE SPECIFIED, PROVIDE FACTORY PERSONNEL FOR

TESTING AND ADJUSTING. SUBMIT QUALITY ASSURANCE PROGRAM

AND DETAILED TESTING PROCEDURES FOR REVIEW.

3.05 EXISTING FACILITIES

A. EXAMINE THE DRAWINGS AND SPECIFICATIONS OF THE COMPLETE

WORK, AND INSPECT THE SITE TO ESTABLISH THE SCOPE OF

DEMOLITION WORK AND NEW WORK TO BE PROVIDED UNDER THIS

SECTION AND CLARIFICATION OF THE PHASING OF THE WORK.

B. BASED ON PROJECT PHASING AND SCHEDULING, DEMOLITION WORK

WILL BE TAKING PLACE IN AND AROUND EXISTING AREAS THAT ARE

TO REMAIN IN SERVICE. WHERE THE WORK UNDER THIS SECTION

AFFECTS OR INTERFERES WITH THE OPERATION OF EXISTING AREAS

TO REMAIN IN SERVICE, OR PORTIONS OF THE WORK ALREADY IN

OPERATION, PROVIDE NECESSARY WORK AND MATERIAL INCLUDING

PREMIUM PAY, REQUIRED TO AVOID SHUTDOWN OF THESE AREAS

DURING NORMAL OPERATIONS. OBTAIN OWNER'S APPROVAL FOR

SHUTDOWN, IN WRITING, 48 HOURS PRIOR TO SHUTDOWN.

C. EXISTING ELECTRICAL AND SIGNAL FACILITIES OUTSIDE OF THE

DEMOLITION AREA TO REMAIN IN PLACE AND IN SERVICE DURING

DEMOLITION.

D. UNLESS SPECIFICALLY NOTED OR OTHERWISE INDICATED OR

DIRECTED, REMOVE EXISTING ELECTRICAL EQUIPMENT IN THE

AREAS TO BE DEMOLISHED. DELIVER EQUIPMENT REMOVED,

INCLUDING LIGHTING FIXTURES, TO THE OWNER'S REPRESENTATIVE.

3.06 REMODELING

A. WHERE REMODELING OF EXISTING AREAS IS INDICATED, PROVIDE

WORK INDICATED AND REQUIRED FOR A COMPLETE AND OPERATING

FACILITY. WHERE WORK IS ADJACENT TO EXISTING FIXTURES OR

DEVICES, PROVIDE MATCHING PRODUCTS TO PRESENT UNIFORM

APPEARANCE. SALVAGE DEMOLISHED MATERIAL AND EQUIPMENT

AND DELIVER TO OWNER AS DIRECTED. DISPOSE OF SALVAGED

MATERIAL AND EQUIPMENT WHERE SO DIRECTED IN WRITING BY

OWNER. PATCH OPENINGS IN EXISTING WALLS OR FLOORS CAUSED

BY REMOVAL OF MATERIAL AND/OR EQUIPMENT UNDER THIS WORK.

B. VERIFY ALL EXISTING FIXTURES TO BE REUSED ARE FUNCTIONAL

PRIOR TO BIDDING. PROVIDE NEW LAMPS AT ALL REUSED FIXTURES.

3.07 DEMOLITION

A. WHERE AREAS OF EXISTING FACILITIES ARE INDICATED TO BE

DEMOLISHED OR REMODELED, VISIT SITE TO DETERMINE SCOPE OF

WORK. RELOCATE ELECTRIC AND SIGNAL SYSTEM EQUIPMENT, AND

REROUTE OR REPLACE CONDUIT AND WIRING TO CONFORM WITH

NEW USE OF THE AREA AND MAINTAIN OPERATION OF ADJACENT

AREAS.

3.08 FLASHING

A. WHEREVER CONDUIT EXTENDS THROUGH ROOF, INSTALL A FOUR

POUND SEAMLESS LEAD FLASHING ASSEMBLY AND COUNTER

FLASHING.

3.09 TESTS AND CERTIFICATION

A. GENERAL: PROVIDE TESTING IN ACCORDANCE WITH NETA

REQUIREMENTS, AS SPECIFIED UNDER INDIVIDUAL EQUIPMENT AND

SYSTEM SPECIFICATIONS AND AS FOLLOWS:

1. UPON COMPLETION OF THE WORK, AND AS A CONDITION FOR

ACCEPTANCE, TEST ALL COMPONENTS AND SYSTEMS IN THE

PRESENCE OF THE OWNER'S REPRESENTATIVE TO DEMONSTRATE

COMPLIANCE WITH THE SPECIFICATIONS. PROVIDE TESTS AS

SPECIFIED AND AS REQUIRED BY THE CODE OR ENFORCING

AUTHORITIES. ADJUST, REPAIR AND/OR REPLACE DEFECTIVE

MATERIAL AND EQUIPMENT.

2. TIGHTEN ALL BOLTED CONNECTIONS AND MEGGAR ALL EQUIPMENT

AND BUS PRIOR TO TESTING.

3. TABULATE ALL TEST DATA AND PREPARE CERTIFIED TYPEWRITTEN

REPORT COVERING ALL TESTING PERFORMED AND INCLUDE IN

OPERATING AND MAINTENANCE INSTRUCTION MANUAL(S).

3.10 INSTALLATION OF CONDUCTORS

A. STORE CONDUCTORS WHERE CONTINUOUSLY PROTECTED FROM

SUNLIGHT, HEAT AND WEATHER.

B. CIRCUIT AS INDICATED ON PLANS AND SINGLE LINE DIAGRAMS.

C. DO NOT INSTALL MORE CONDUCTORS IN A RACEWAY THAN

INDICATED ON THE DRAWINGS.

D. MINIMUM WIRE SIZE SHALL BE NO. 12 AWG, EXCEPT FOR CONTROL

OR SIGNAL CIRCUITS WHICH MAY BE NO. 14 AWG.

E. ALL WIRING FOR BRANCH CIRCUITS SHALL BE MINIMUM NO. 12 AWG,

PROTECTED BY 20 AMPERE CIRCUIT BREAKERS. IF DISTANCE FROM

PANEL TO FIRST OUTLET IS 75' OR GREATER FOR 120 VOLT CIRCUITS,

AND 125' OR GREATER FOR 277 VOLT CIRCUITS, NO. 10 AWG SHALL

BE INSTALLED THROUGHOUT THE CIRCUIT, UNLESS NOTED

OTHERWISE ON THE DRAWINGS.

F. PROVIDE CONDUCTORS IN PARALLEL FEEDER RUNS OF IDENTICAL

LENGTHS.

G. ACCEPTABLE PULLING MEANS INCLUDE: FISH TAPE WITH BALL TYPE

HEADS, CABLE ROPE, AND BASKET WEAVE WIRE/CABLE GRIPS WHICH

DO NOT DAMAGE CABLES OR RACEWAYS. DO NOT USE ROPE

HITCHES FOR PULLING ATTACHMENTS TO WIRE OR CABLE.

H. USE ONLY LUBRICANT, WHICH DOES NOT DAMAGE CONDUCTORS, AS

A PULLING AID. NO LUBRICANT IS TO BE USED ON BRANCH CIRCUIT

CONDUCTORS CONNECTED TO GROUND FAULT-INTERRUPTING

CIRCUIT BREAKERS.

I. BUNDLE AND SECURE FEEDER, BRANCH CIRCUIT AND CONTROL

CONDUCTORS, IN PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL

CENTERS, AND TERMINAL CABINETS WITH NYLON TIE WRAPS

SUITABLE FOR CONDUCTOR SIZE. PROVIDE TIE WRAPS ON

APPROXIMATELY 12" CENTERS. IDENTIFY SPARE CONDUCTORS (LINE,

CONTROL AND SIGNAL).

J. TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS, INCLUDING

SCREWS AND BOLTS, IN ACCORDANCE WITH MANUFACTURER'S

PUBLISHED TORQUE TIGHTENING VALUES. WHERE MANUFACTURER'S

TORQUE REQUIREMENTS ARE NOT INDICATED, TIGHTEN

CONNECTORS AND TERMINALS TO COMPLY WITH TIGHTENING

TORQUE VALUES SPECIFIED IN UL 486A AND UL 486B.

K. INSTALL ALL CONDUCTORS IN CONDUIT. COMPLETE CONDUIT

SYSTEM AND CLEAN AND DRY CONDUIT BEFORE PULLING IN

CONDUCTORS. INSTALL CONDUCTORS AFTER GENERAL

CONSTRUCTION WORK IN AREA HAS PROGRESSED SUFFICIENTLY TO

AVOID CONDUCTOR DAMAGE.

L. RUN NEUTRAL CONDUCTORS CONTINUOUS TO PANEL. DO NOT

COMBINE. RUN FEEDERS CONTINUOUS TO PANEL OR EQUIPMENT

WITHOUT SPLICES. DO NOT SPLICE OR TAP IN EQUIPMENT

ENCLOSURES OR CONDUIT BODIES. MAKE NECESSARY SPLICES ON

TAPS ONLY IN JUNCTION BOXES, PULL BOXES, OR IN OVERSIZE

WIRING GUTTERS DESIGNED FOR THE PURPOSE AT PANELBOARDS.

M. ALLOW 8" MINIMUM FREE LENGTH OF CONDUCTOR WHERE

TERMINATING IN OUTLET OR PULL BOX. PROVIDE LONGER LENGTHS

WHERE INDICATED.

N. DO NOT LOOP THROUGH RECEPTACLE TERMINALS: CONNECT BY

MEANS OF CONDUCTOR TAPS JOINED TO BRANCH CIRCUIT

CONDUCTORS.

3.11 CONNECTIONS AND TERMINATIONS, LINE VOLTAGE CONDUCTORS:

A. FOR BRANCH CIRCUIT CONDUCTORS NO. 8 AWG AND SMALLER, USE

STEEL SPRING WITH SEMI-RIGID INSULATING SHELL, OR SETSCREW

TYPE, TAPED.

B. FOR CONDUCTORS NO. 6 AWG AND LARGER, USE COPPER OR

BRONZE BOLTED PRESSURE BAR MECHANICAL CONNECTORS AND

LUGS, OR COMPRESSION TYPE AT CONTRACTOR'S OPTION, SIZED

FOR CONDUCTORS. FOR CONDUCTORS NO. 1 AWG AND LARGER, USE

LUGS WITH TWO BOLTS THROUGH TONGUE MINIMUM, OR EQUAL

ANTI-TURN CONSTRUCTION (SUBMIT SAMPLE). CONNECTORS AND

LUGS WHICH ARE CRIMP TYPE OR WHICH APPLY SETSCREWS

DIRECTLY TO THE CONDUCTORS ARE NOT ACCEPTABLE. FASTEN

LUGS WITH FLAT AND SPRING WASHERS AND HEX NUT.

C. COORDINATE EQUIPMENT TERMINATIONS WITH EQUIPMENT

SUPPLIER TO INSURE THAT TERMINALS PROVIDED CONFORM WITH

REQUIREMENTS SPECIFIED HEREIN.

D. FOR CONNECTIONS AT MOTORS, USE LUGS ON MOTOR AND BRANCH

CIRCUIT CONDUCTORS, BOLTED AND TAPED. FOR CONDUCTORS NO.

8 AWG AND SMALLER, CRIMP LUGS TO CONDUCTORS.

E. SPLICE GROUNDING CONDUCTORS BY MEANS OF EXOTHERMIC

WELDING AND TERMINATE BY MEANS OF APPROVED GROUNDING

CONNECTORS. DO NOT SOLDER.

F. POSITION SPLICES IN PULL BOXES AND JUNCTION BOXES, SO THEY

ARE ACCESSIBLE FROM THE REMOVABLE COVER SIDE OF THE BOX.

G. PROVIDE WATERPROOF CONNECTIONS IN WET LOCATIONS. PENCIL

AND ROUGHEN CONDUCTORS AND APPLY RUBBER TAPE EQUAL TO

INSULATION THICKNESS. COVER WITH TWO HALF-LAPPED LAYERS OF

8.5 MIL, ALL WEATHER, VINYL PLASTIC TAPE, SUITABLE FOR BELOW

FREEZING APPLICATION, AND COAT WITH SEALANT. FORM

CONDUCTORS INTO DRIP LOOPS SO THAT WATER DOES NOT

COLLECT ON CONNECTIONS. BLOW OUT CONDUIT TO REMOVE

MOISTURE AND SEAL CONDUIT ENDS WITH WATERPROOF

COMPOUND.

H. TORQUE ELECTRICAL CONDUCTOR TERMINATIONS IN ACCORDANCE

WITH EQUIPMENT MANUFACTURER'S DIRECTIONS AND INDUSTRY

STANDARDS.

3.12 CONDUIT

A. USE RIGID STEEL CONDUIT UP TO 6", OR INTERMEDIATE STEEL

CONDUIT UP TO 4": IN SLAB ON GRADE; ON EXTERIOR; ENCASED IN

EXTERIOR MASONRY OR CONCRETE WALLS; IN WET LOCATIONS; IN

REFRIGERATED SPACES; WHERE CONDUIT IS ROUTED EXPOSED

WITHIN 7 FEET OF FLOOR OR WALKING SURFACES; IN SUSPENDED

SLABS, BUT ONLY WHERE PERMISSION IS OBTAINED FROM

ARCHITECT IN WRITING FOR CONDUIT TO BE RUN IN A SUSPENDED

SLAB.

B. USE RIGID OR INTERMEDIATE STEEL CONDUIT, OR ELECTRIC

METALLIC TUBING UP TO 4" FOR: DRY CONCEALED LOCATIONS;

WHERE CONDUIT IS ROUTED EXPOSED ABOVE 7 FEET FROM FLOOR

OR WALKING SURFACES; INCLUDING BUT NOT LIMITED TO

MECHANICAL ROOMS, IN ELECTRICAL AND TELEPHONE ROOMS AT

ALL HEIGHTS.

C. USE FLEXIBLE STEEL CONDUIT, 1/2” MINIMUM, AND 3/4” MAXIMUM,

TRADE SIZE, IN METAL STUD PARTITIONS AND ABOVE ACCESSIBLE

LAY-IN TILE CEILINGS. DO NOT USE FLEXIBLE CONDUIT FOR

HOMERUNS TO PANELBOARDS, OR FOR EMERGENCY CIRCUITS.

D. USE 24" MINIMUM LENGTH OF LIQUIDTIGHT FLEXIBLE STEEL CONDUIT,

1/2" MINIMUM TRADE SIZE, SLACK CONNECTED FOR: CONNECTION

FROM OUTLET TO MOTOR AND OTHER MOVING OR VIBRATING

EQUIPMENT; CODE LENGTH TO LIGHTING FIXTURES IN DAMP OR WET

LOCATIONS; TO TRANSFORMER HOUSINGS; TO KITCHEN EQUIPMENT;

ALL FLEXIBLE CONNECTIONS IN EXPOSED AREAS. WHERE CONDUIT

STUBS INTO BOTTOM OF DRY TYPE TRANSFORMER, WITHOUT

CONNECTING TO ENCLOSURE, BOND CONDUIT TO ENCLOSURE AND

OMIT FLEX CONNECTION.

E. PROVIDE BEND RADIUS FOR FLEXIBLE CONDUIT NOT LESS THAN 5

TIMES THE TRADE SIZE.

F. DO NOT USE FLEXIBLE CONDUIT FOR TELECOMMUNICATIONS OR

DATA CABLING UNLESS SPECIFICALLY SHOWN ON THE DRAWINGS.

G. WHERE PENETRATING FLOORS OR FIRE SEPARATIONS, USE UL

LISTED FITTINGS AND/OR DEVICES TO MAINTAIN SEPARATION

INTEGRITY.

3.13 INSTALLATION OF CONDUIT

A. DELIVER RACEWAYS AND WIREWAYS TO THE SITE IN STANDARD

LENGTHS, AND STORE WHERE CONTINUOUSLY PROTECTED FROM

MOISTURE AND WEATHER.

B. CONDUIT SIZES ON THE DRAWINGS ARE MINIMUM, SIZED FOR

COPPER CONDUCTORS, FOR NORMAL DIMENSION INSULATION.

UNLESS OTHERWISE NOTED, USE 1/2" TRADE SIZE MINIMUM.

INCREASE SIZES WHERE REQUIRED BY PHYSICAL CONDITIONS, OR

CONDUCTOR INSULATION. DO NOT COMBINE RUNS WITHOUT

WRITTEN APPROVAL. ALLOW FOR GROUNDING CONDUCTOR.

C. CONCEAL CONDUIT FROM VIEW ABOVE CEILINGS, BELOW FLOORS OR

IN WALLS. REFER TO ARCHITECTURAL SECTIONS AND DETAILS TO

DETERMINE CONDUIT ROUTING REQUIRED TO CONCEAL CONDUIT.

D. CONDUIT MAY BE EXPOSED TO VIEW IN SHOP AND UTILITY AREAS

AND WHERE INDICATED. INSTALL ALL CONDUIT RUNS PARALLEL

WITH OR PERPENDICULAR TO STRUCTURAL MEMBERS. SURMOUNT

OBSTRUCTIONS BY USE OF BENDS, OFFSETS, AND WHERE

NECESSARY WITH JUNCTION AND PULL BOXES. FOR SURFACE

MOUNTED OUTLETS AND SMALL JUNCTION BOXES WITHIN 7' OF

FLOOR, USE CAST BOXES AND/OR CONDUIT BODIES.

E. CUT CONDUITS AND RACEWAYS SQUARE AND FREE OF BURRS. REAM

CONDUIT ENDS AND CLEAN CONDUITS BEFORE PULLING

CONDUCTORS.

F. CAP OPEN ENDS OF CONDUITS WITH APPROVED MANUFACTURED

CONDUIT SEALS UNTIL READY TO PULL IN CONDUCTORS.

G. FOR BENDS AND OFFSETS IN CONDUIT, USE LARGE RADIUS FACTORY

FITTINGS, OR BEND WITH HYDRAULIC BENDER MEETING THE NEC

REQUIREMENTS. REPLACE ALL FLATTENED, DEFORMED OR KINKED

CONDUIT.

H. PROVIDE NO. 14 AWG BLACK IRON PULL WIRE OR POLYETHYLENE OR

NYLON PULL ROPE IN ALL EMPTY CONDUITS AND STUBS OVER 10' IN

LENGTHS, EXTENDING AT LEAST 12" BEYOND CONDUIT. PULL ROPE

TENSILE STRENGTH TO BE 240 POUNDS UP TO 1-1/2" CONDUIT AND

800 POUNDS FOR LARGER CONDUIT.

I. SECURE RIGID OR IMC CONDUITS TO PANELBOARDS, PULL BOXES,

WIREWAYS AND ENCLOSURES WITH LOCKNUTS, INSIDE AND OUT,

AND PROVIDE IMPACT RESISTANT PLASTIC, INSULATED THROAT OR

MALLEABLE IRON BUSHINGS AT TERMINATIONS IN PULL BOXES,

WIREWAYS, SIGNAL CABINETS, BOXES AND ENCLOSURES. ZINC

INSULATED THROAT HUBS WITH "O" RING GASKETS MAY BE USED IN

LIEU OF DOUBLE LOCKNUT AND BUSHING. FOR FEEDER

CONDUCTORS NO. 4 AWG AND LARGER, PROVIDE STEEL OR

MALLEABLE IRON INSULATING BUSHINGS WITH PLASTIC LINER. FOR

EMT, PROVIDE INSULATED THROAT CONNECTORS SECURED WITH

LOCKNUT ON INTERIOR OF BOX OR ENCLOSURE.

J. FIELD THREAD RIGID AND IMC CONDUIT TO CONFORM TO AMERICAN

STANDARD PIPE THREADS TAPERED FOR THE ENTIRE LENGTH AT 3/4

INCH/FOOT. TREAT THREADS WITH PROTECTIVE COATING TO

PREVENT CORROSION, BUT MAINTAIN ELECTRICAL CONTINUITY.

K. UPON COMPLETION OF INSTALLATION OF RACEWAYS, INSPECT

INTERIORS OF RACEWAYS; CLEAR ALL BLOCKAGES AND REMOVE

BURRS, DIRT, AND CONSTRUCTION DEBRIS.

3.14 INSTALLATION OUTLET BOXES AND FITTINGS

A. GENERAL: INSTALL ELECTRICAL BOXES AND FITTINGS IN

ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS,

APPLICABLE REQUIREMENTS OF THE CODE AND NECA'S "STANDARD

OF INSTALLATION," AND IN ACCORDANCE WITH RECOGNIZED

INDUSTRY PRACTICES TO FULFILL PROJECT REQUIREMENTS.

B. COORDINATE INSTALLATION OF ELECTRICAL BOXES AND FITTINGS

WITH CONDUCTORS, WIRING DEVICES, AND RACEWAY INSTALLATION

WORK.

C. INSTALL OUTLETS AND BOXES IN READILY ACCESSIBLE LOCATIONS.

D. INSTALLING BOXES BACK-TO-BACK IN WALLS IS NOT PERMITTED.

PROVIDE A MINIMUM OF 12" OF SEPARATION.

E. AVOID USING ROUND BOXES WHERE CONDUIT MUST ENTER BOX

THROUGH SIDE OF BOX, WHICH WOULD RESULT IN DIFFICULT AND

INSECURE CONNECTIONS WHEN FASTENED WITH LOCKNUT OR

BUSHING ON ROUNDED SURFACES.

F. TAPS AND SPLICES WHERE PERMITTED BY THESE SPECIFICATIONS

WITHIN EXTERIOR JUNCTION BOXES, SHALL BE PERFORMED WITH AN

ENCAPSULATING WATERTIGHT SPLICE OR TAP KIT WHICH INSULATES

AND MOISTURE SEALS THE CONNECTION. KIT SHALL CONSIST OF THE

APPROPRIATE SIZE AND TYPE MOLD, ENCAPSULATING RESIN AND

END SEALING TAPE.

G. SUBSEQUENT TO INSTALLATION OF BOXES, PROTECT BOXES FROM

CONSTRUCTION DEBRIS AND DAMAGE.

H. PROVIDE ADDITIONAL PULL OF JUNCTION BOXES AS REQUIRED TO

MEET CODE REQUIREMENTS OR TO FACILITATE PULLING OF WIRES.

LOCATE IN UTILITY AREAS, ABOVE ACCESSIBLE CEILINGS, ON IN

APPROVED LOCATIONS.

I. SIZE BOXES FOR DEVICES CONTAINED AND THE NUMBER OF WIRES

PASSING THROUGH OR TERMINATING THEREIN, BUT NOT LESS THAN

4" SQUARE BY 1-1/2" DEEP. USE PULL AND JUNCTION BOXES OF

ADEQUATE SIZE FOR SPLICES AND TERMINATIONS CONTAINED

THEREIN.

J. USE 4-11/16" SQUARE BOX WITH ROUND PLASTER RING, FOR

SURFACE MOUNTED CEILING FIXTURES.

K. WHERE MORE THAN ONE SWITCH IS SHOWN AT ONE LOCATION,

GROUP BEHIND COMMON PLATE. USE GANG BOXES FOR THREE OR

MORE DEVICES. PROVIDE BARRIER BETWEEN 277V SWITCHES

CONTROLLING TWO OR MORE CIRCUITS.

L. UNLESS SPECIFIED OTHERWISE IN OTHER SECTIONS, PROVIDE A

4-11/16" SQUARE BY 2-1/8" DEEP BOX WITH ONE GANG FLUSH

PLASTER RING FOR WALL MOUNTED TELEPHONE, DATA, COMPUTER,

DICTATION, MATV OR INTERCOM OUTLETS.

M. RECESS BOXES, EXCEPT IN UNFINISHED AREAS SUCH AS UTILITY

TUNNELS, MECHANICAL, AND ELECTRICAL SPACES. PROVIDE

EXTENSION RINGS AND/OR PLASTER RINGS TO FINISH FLUSH WITH

FINISHED SURFACES, INCLUDING THE INSIDE FACE OF THE BACKS OF

CASEWORK. INSTALL APPROVED FACTORY MADE KNOCKOUT SEALS

WHERE KNOCKOUTS ARE NOT INTACT, AND CLOSE ALL OPENINGS.

N. USE CAST METAL, GASKETED BOXES FOR LOCATIONS NOTED ON

DRAWINGS AND AS FOLLOWS: STUB MOUNTED OUTLETS; SURFACE

MOUNTED OUTLETS WITHIN 7' OF THE FLOOR; WET OR CORROSIVE

LOCATIONS; OUTLETS ON THE EXTERIOR OR WITHIN EXTERIOR

WALLS FACING THE EXTERIOR. FOR FLUSH MOUNTED OUTLETS,

PROVIDE ADAPTER PLATES. PROVIDE THREADED PLUGS IN UNUSED

HUBS.

O. SUPPORT LIGHT FIXTURE OUTLETS TO BUILDING STRUCTURE AND

EQUIP WITH FIXTURE STUD AND HANGAR BAR OR SUPPORTING

DEVICE AS REQUIRED. SUPPORT LIGHTING FIXTURES IN EXCESS OF

60 POUNDS TO STRUCTURE INDEPENDENTLY OF OUTLET BOX.

P. PROVIDE BOXES FOR ALL DEVICES. FOR DEVICES NOT SPECIFIED OR

SCHEDULED, USE BOXES AS APPROVED, ADEQUATE FOR DEVICE TO

BE INSTALLED.

Q. COMBINE DEVICES IN GANGED BOX WITH SUITABLE BARRIERS

BEHIND COMMON PLATE WHERE INDICATED, SPECIFIED, OR

DETAILED. PROVIDE SEPARATE OR BARRIERED BOXES FOR NORMAL

AND EMERGENCY DEVICES.

R. INSTALL BOXES IN A RIGID MANNER, WITH BOX HANGERS,

EXPANSION SHIELDS IN MASONRY, AND MACHINE SCREWS ON METAL

WORK. DO NOT NAIL TO STRUCTURE. USE PLATED OR GALVANIZED

SCREWS THROUGHOUT.

S. SECURE PULL AND JUNCTION BOXES TO THE STRUCTURE

INDEPENDENTLY OF THE CONDUITS BY MEANS OF BOLTS, ROD

HANGERS OR BRACKETS.

3.15 SUPPORT AND FASTENING OF RACEWAYS AND WIREWAYS

A. INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL

COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WITH

CODE REQUIREMENTS.

B. COORDINATE WITH THE BUILDING STRUCTURAL SYSTEM, AND WITH

OTHER ELECTRICAL, HVAC AND PLUMBING SYSTEMS INSTALLATIONS.

C. INSTALL RIGID STEEL CONDUIT WITH THREADED COUPLINGS.

SUPPORT CONDUITS 1" AND LARGER ON 10 FOOT INTERVALS,

SMALLER THAN 1" ON 7 FOOT INTERVALS, ALL SIZES WITHIN 3' OF

CONNECTION TO ANY ELECTRICAL ENCLOSURE, BOX, CABINET, OR

FITTING, INCLUDING COUPLINGS.

D. SUPPORT ELECTRIC METALLIC TUBING ON MAXIMUM SPACING OF 10'

AND WITHIN 3' OF CONNECTION TO ANY ELECTRICAL ENCLOSURE,

BOX, CABINET, OR FITTING, INCLUDING COUPLINGS.

E. AT PLASTER OR DRYWALL PARTITIONS, ATTACH ONLY TO THE

FRAMING STUDS OR TO A BACKING PLATE OR STEEL CHANNEL THAT

SPANS BETWEEN STUDS.

F. ATTACH TO SOLID MASONRY WALLS WITH STEEL WEDGE EXPANSION

ANCHORS.

G. DO NOT FASTEN RIGID CONDUIT OR TUBING TO EQUIPMENT SUBJECT

TO VIBRATION OR MOUNTED ON SHOCK MOUNTS.

H. WHERE ATTACHING TO STEEL MEMBERS, USE BEAM CLAMP, WELDED

THREADED STUDS, OR MACHINE SCREWS.

I. WHERE NOT OTHERWISE SPECIFIED HEREIN, SUPPORT ALL SIZES OF

SUSPENDED CONDUIT FROM BEAMS OR GIRDERS WITH FACTORY

MADE PIPE HANGERS WITH SPLIT HINGED MALLEABLE IRON OR

SPRINGABLE STEEL PIPE RINGS AND SOLID ROUND MILD STEEL

RODS, 1/4" DIAMETER FOR UP TO 1-1/4" CONDUIT, 3/8" DIAMETER UP

TO 2" CONDUIT, AND 1/2" DIAMETER FOR LAGER CONDUIT. FRICTION

TYPE CONDUIT SUPPORT HARDWARE AND ATTACHMENTS ARE NOT

ACCEPTABLE. WHERE REQUIRED CONDUIT SUPPORT SPACING IS

MORE FREQUENT THAN STRUCTURAL MEMBERS, PROVIDE

INTERMEDIATE STEEL SUPPORT AS REQUIRED.

J. PROVIDE TRAPEZE TYPE HANGERS WHERE THREE OR MORE

CONDUITS RUN PARALLEL AND CLAMP CONDUIT TO HANGER WITH

GALVANIZED STEEL CONDUIT CLAMPS. PROVIDE DIAGONAL SEISMIC

BRACING FOR SUSPENDED RUNS OF CONDUITS 2-1/2" TRADE SIZE

AND LARGER. UTILIZE U-CHANNELS FOR TRAPEZE ASSEMBLIES.

LATHING CHANNELS ARE NOT ACCEPTABLE.

K. DO NOT USE PERFORATED METAL STRAP OR WOOD AS SUPPORT

MATERIAL.

L. SUPPORT CONDUIT TO STRUCTURE ABOVE SUSPENDED CEILINGS 3"

MINIMUM ABOVE CEILING TO ALLOW REMOVAL OF TILE. DO NOT

SUPPORT FROM T-BARS OR T-BAR HANGER WIRES. MAINTAIN 2"

CLEARANCE ABOVE RECESSED LIGHT FIXTURES.

M. ABOVE FIXED CEILINGS AND IN STUD WALLS, TIE CONDUIT 1" OR

SMALLER TO FURRING, SUPPORT CHANNELS CAPABLE OF CARRYING

THE WEIGHT, OR STUDS WITH NO. 16 GAUGE GALVANIZED WIRE TIES

4' ON CANTER, MAXIMUM.

N. SUPPORT EXPOSED CONDUITS ON ROOFTOPS ON STEEL PEDESTALS

WITH RUBBER BASES THAT REST ON TOP OF ROOFING MEMBRANE,

NOT REQUIRING ANY ATTACHMENT TO THE ROOF STRUCTURE AND

NOT PENETRATING THE ROOFING ASSEMBLY, WITH SUPPORT

FIXTURES AS RECOMMENDED BY THE MANUFACTURER. MINIMUM OF

4-1/2" HIGH BY 6" WIDE BY 9-3/5" LONG. THE BASE SHALL BE

COMBINED WITH A MINIMUM 7/8" HIGH, 14 GAUGE GALVANIZED STEEL

U-CHANNEL, FASTENED TO THE BASE, TO FORM THE BASIC SUPPORT

SYSTEM. A SINGLE BASE WITH U-CHANNEL SHALL PROVIDE AN

ULTIMATE LOAD CAPACITY OF 500 LBS PER LINEAR FOOT, MINIMUM.

3.16 INSTALLATION OF LIGHTING FIXTURES

A. COORDINATE EXACT QUANTITIES AND CRITICAL DIMENSIONS WITH

THE CONTRACT DOCUMENTS AND FIELD CONDITIONS.

B. INSTALL LIGHTING FIXTURES IN ACCORDANCE WITH FIXTURE

MANUFACTURER'S WRITTEN INSTRUCTIONS, APPLICABLE

REQUIREMENTS OF THE CODE, NECA'S "STANDARD OF

INSTALLATION," NEMA STANDARDS, AND WITH RECOGNIZED

INDUSTRY PRACTICES TO ENSURE THAT LIGHTING FIXTURES FULFILL

INSTALLATION REQUIREMENTS.

C. INSTALL RECESSED FIXTURES PROPERLY TO ELIMINATE LIGHT

LEAKAGE BETWEEN FIXTURE FRAME AND FINISHED SURFACE.

PROVIDE PLASTER FRAMES FOR RECESSED FIXTURES INSTALLED IN

OTHER THAN SUSPENDED GRID TYPE ACOUSTICAL CEILING

SYSTEMS. BRACE FRAMES TEMPORARILY TO PREVENT DISTORTION

DURING HANDLING.

D. CONNECTIONS: USE UNDERWRITERS' LABORATORIES APPROVED

SOLDERLESS CONNECTORS FOR SPLICING.

E. BLOCKING: PROVIDE SUPPLEMENTAL BLOCKING AND SUPPORT

UNDER THIS SECTION, AS REQUIRED TO SUPPORT FIXTURE FROM

STRUCTURAL MEMBERS ADEQUATE FOR FIXTURE WEIGHT. REFER

TO THE ARCHITECTURAL DETAILS FOR ACCEPTABLE METHODS FOR

BLOCKING AND SUPPORT IN WALLS AND CEILINGS.

F. SURFACE MOUNTED FIXTURES: SECURE TO STRUCTURAL MEMBERS

OR TO STRUCTURAL CHANNELS WHICH SPAN STRUCTURAL

MEMBERS WITH 1/4" MINIMUM MACHINE SCREWS.

G. CONNECTIONS: DO NOT USE FIXTURES AS PULL OR JUNCTION

BOXES. DO NOT USE FLEX CONDUIT BETWEEN SEPARATED,

SUSPENDED FIXTURES. SURFACE MOUNTED FIXTURES, SEPARATED

BY NOT MORE THAN 6" IN UTILITY AREAS, ARE TO BE NIPPED

TOGETHER. CONNECT FROM RECESSED FIXTURES TO FIXTURE

OUTLET WITH 6" LENGTH OF FLEXIBLE CONDUIT AND CONDUCTORS.

H. LOCATION: LOCATE FIXTURE OUTLETS, RECESSED FIXTURES, AND

DETERMINE THE LENGTH OF CUSTOM, CONTINUOUS ROW COVE OR

"REVERSE COVE" FIXTURES, BY REFERENCE TO ARCHITECTURAL

REFLECTED CEILING PLANS AND DETAILS AND MEASUREMENT OF

BUILDING CONSTRUCTION. DO NOT SCALE ELECTRICAL DRAWINGS.

I. LAMPING: FOR INITIAL LAMPING OF OVERHEAD FIXTURES DURING

CONSTRUCTION, OMIT DIFFUSER INSTALLATION. PRIOR TO FINAL

ACCEPTANCE AND WHEN DIRECTED BY THE OWNER IN WRITING,

CLEAN THE FIXTURES, REMOVE CONSTRUCTION LAMPS, RELAMP

WITH NEW LAMPS AND INSTALL DIFFUSERS.

J. DO NOT INSTALL EXPOSED FIXTURES, REFLECTORS OR TRIMS UNTIL

ALL PLASTERING AND PAINTING THAT MAY MAR FIXTURE FINISH IS

COMPLETED. REPLACE BLEMISHED, DENTED, DAMAGED OR

UNSATISFACTORY FIXTURES AS DIRECTED.

K. SUPPORT ALL FIXTURES INDEPENDENT OF DUCTWORK OR PIPING.

3.17 GROUNDING AND BONDING

A. CONDUCTORS

1. INSULATED CONDUCTORS: COPPER WIRE OR CABLE INSULATED FOR

600 V UNLESS OTHERWISE REQUIRED BY APPLICABLE CODE OR

AUTHORITIES HAVING JURISDICTION.

B. INSTALLATION

1. CONDUCTORS: INSTALL SOLID CONDUCTOR FOR NO. 8 AWG AND

SMALLER, AND STRANDED CONDUCTORS FOR NO. 6 AWG AND

LARGER, UNLESS OTHERWISE INDICATED.

2. INSTALL INSULATED EQUIPMENT GROUNDING CONDUCTORS WITH

ALL FEEDERS AND BRANCH CIRCUITS.

3.18 ACCEPTABLE MANUFACTURERS

A. MOLDED CASE CIRCUIT BREAKERS:

1. FOR BRANCH CIRCUIT PANELBOARDS: SAME AS PANELBOARD

MANUFACTURER.

2. FOR SWITCHBOARDS: SAME AS SWITCHBOARD MANUFACTURER.

B. DISCONNECT SWITCHES (HEAVY DUTY, QUICK-MAKE, QUICK-BREAK):

1. 800A AND SMALLER: GENERAL ELECTRIC, SQUARE D, CUTLER

HAMMER AND SIEMENS. REJECTION TYPE FOR FUSED UNITS.

2. MOTOR SWITCHES: FOR 120V, 230V, UP TO 5HP, 460V UP TO 10HP:

SQUARE D CLASS 2510. EQUAL BY GENERAL ELECTRIC, CUTLER

HAMMER OR SIEMENS.

C. FUSES: RK5

D. WIRING DEVICES:

1. MAINTAINED SWITCHES: HUBBELL, LEVITON, PASS/SEYMOUR OR

COOPER.

2. DUPLEX AND SINGLE RECEPTACLES: SPECIFICATION GRADE,

HUBBELL, LEVITON, COOPER OR PASS/SEYMOUR.

3. WEATHERPROOF HINGED COVER: HUBBELL, INTERMATIC, LEVITON

OR PASS/SEYMOUR.

4. PLATES - SMOOTH, SATIN FINISH, TYPE 302, 0.035" STAINLESS STEEL:

HUBBELL, LEVITON, COOPER OR PASS/SEYMOUR.

E. INSULATED BUSHINGS: O.Z. GEDNEY TYPES A, B AND COPPER LUG

BLG, OR APPROVED EQUIVALENT.

F. EMT FITTINGS - STEEL RAINTIGHT: APPLETON, CROUSE-HINDS, STEEL

CITY OR THOMAS AND BETTS.

G. LIQUIDTIGHT FLEX: TYPE U.A. WITH BUILT-IN BOND WIRE, AMERICAN

FLEX CONDUIT, ANACONDA OR O.Z. GEDNEY.

H. STEEL OUTLET BOXES: 4: SQUARE BY 1-1/2" DEEP MINIMUM,

APPLETON, STEEL CITY, THOMAS AND BETTS OR CROUSE-HINDS.

I. CAST BOXES AND CONDUIT BODIES: APPLETON, CROUSE-HINDS,

PYLE-NATIONAL, O.Z. GEDNEY OR CROUSE-HINDS.

J. 600V CONDUCTOR INSTALLATION ACCESSORIES:

1. STEEL SPRING CONNECTORS (NO. 8 AND SMALLER): SCOTCHLOCK

TYPES R AND Y, IDEAL WIRENUT.

2. SOLDERLESS CONNECTORS: (NO. 6 AND LARGER) COPPER OR

BRONZE BOLTED PRESSURE BAR TYPE: BRUNDY, THOMAS AND

BETTS, O.Z. GEDNEY, TELEDYNE PENN-UNION.

3. POWER DISTRIBUTION BLOCKS: SQUARE D CLASS 9080, EQUIVALENT

BY MARATHON SPECIAL PRODUCTS OR ILSCO.

4. COMPRESSION CONNECTORS (MOTOR CONNECTIONS NO.8 AND

SMALLER): T&B STAKON, BURNDY OR EQUIVALENT.

5. TAPE: SCOTCH #23 RUBBER TAPE AND #33 VINYL TAPE. SOLA BASIC,

SIERRA-TOMIC.

6. SEALANT: SCOTCHKOTE. NO KNOWN EQUAL.

7. PULLING COMPOUND: POWDERED SOAPSTONE, IDEAL YELLOW 77,

WIRELUBE, MINERALLAC #100, SIERRA-TOMIC.

8. CABLE SUPPORTS: O.Z. GEDNEY SPLIT WEDGE, KELLEMS CABLE

CLAMPS.

K. AFTERSET ANCHORS: EXPANSION SHIELD TYPE, HILTY KWIK BOLT,

PHILLIPS "READHEAD" WEDGE TYPE.

L. CONDUCTORS - 600V AND BELOW; SOUTHWIRE, ENCORE WIRE,

AMERICAN INSULATED WIRE, ANACONDA, OKONITE.

M. CONDUIT BUSHINGS: SPECIFICATION GRADE, METAL INSULATING

TYPE, INCLUDING GROUNDING BUSHINGS ON 1-1/4" AND LARGER;

METALLIC INSULATING TYPE, 1 INCH AND SMALLER. METAL

INSULATING TYPE BUSHING TO HAVE MOLDED ON HIGH IMPACT

PHENOLIC INSULATION. OZ/GEDNEY OR APPROVED EQUIVALENT.

N. ROOFTOP SUPPORTS: COOPER B-LINE, GASTITE, MIFAB.

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

9:2

6 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

ELECTRICALSPECIFICATIONS

E0.2

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

7/15/2020

Page 25: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

G

GG

G

G

D

2 3 4 5 6 7 8 9

10

9.48.98.2

G

H

I

1.5

D

E

F

OFFICE

H025

OFFICE

H022

OFFICE

H021

OFFICE

H020

TOILET

H024

BREAK ROOM

H023

COMMONELECT

H017

HOLDING

H036

COMMANDSTAFF LKR RM

H037A

FEMALES

H013

MALES

H014

COURT ROOM

H035

ACA

H028

RECEPTION

H001

OFFICE

H002

OFFICE

H003

OFFICE

H004

OFFICE

H005

OFFICE

H006

STORAGE

H007

OFFICE

H008

CONFERENCEROOM

H009

COMPUTERROOM

H010

TELEPHONEROOM

H011

BREAK ROOM

H012

STORAGE

H027

STORAGE

H029

MAIL ROOM

H030

OFFICE

H031

CORRIDOR

H000

OFFICE

I038

OFFICE

I039

ELECTRICALROOM

I040

TELECOMROOM

I041

MENS TOILET

I042

WOMENSTOILET

I043

WOMENS

I003

MENS

I002

VESTIBULE

H037

LOBBY

I001

VESTIBULE

I000

LOBBY

I000A

SECURITYOFFICE

I001A

CELL 1

I011

CELL 2

I012

CELL 3

I013

CELL 4

I014

CELL 5

I015

CELL 6

I016

CELL 7

I017

CELL 8

I018

CELL 9

I019

JANITORS

I020

MEDICALINTERVIEW

I021

MEDICALINTERVIEW

I022

JANITORS

I023

INTOX

I024

INTOX

I025

SALLYPORT

I026

INMATEWAITING

I010

INTEERVIEW

I027

INTERVIEW

I028

INTAKE LOBBY

I029

INTERVIEW

I030

INTERVIEW

I031

INTAKE

I037

STORAGE

I033

BRIEFING

I034

BREAK ROOM

I035

TOILET

I036

MENSPROCESS

I008

WOMENSPROCESS

I009

INTERVIEW

I046

INTERVIEW

I047INMATEWAITING

I044Room

I049

JUDGESCHAMBER

H034

CLERK

H032

TOILET

H033

SALLYPORT

I053

OFFICE

I007

CITY ID

I045

SALLYPORT

I004

VEST

I004A

CORRIDOR

H036A

(R)

(R)

(R)

(R)(R)

(R)

(R)

(R)(R)

(R)

(R) (R) (R)

(R)

(R) (R) (R) (R) (R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R) (R) (R)

(R)(R)

(R)

(R)(R)

(R)

(R)

(R)

E6

(R)E7

(E)(E)

(E) (E)

(E)

(E)

(E) (E)

(E)

(E) (E)

(E)

(E)

(E)

(E)

(E) (E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E) (E)

(E)

(E)

(E)

(E)(E)(E)

(E)

(E)

(E)

(E)

(E)(E)(E)

(E)

(E)

(E) (E)

(R)

(E)

(E)

(E)

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

9:3

6 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

ELECTRICALDEMOLITIONPLAN

ED1.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

1/8" = 1'-0"1 POWER -DEMOLITION

GENERAL NOTES - DEMOLITION

1 ALL ELECTRICAL DEVICES AND LIGHT FIXTURESSHOWN DASHED AND TAGGED "(R)" ARE TO BEDISCONNECTED AND REMOVED, INCLUDING ALLASSOCIATED CONDUIT AND CONDUCTORS BACKTO THE SOURCE OR LAST DEVICE TO REMAINACTIVE. MAINTAIN CONTINUITY FOR EXISTINGDEVICES TO REMAIN.

2 EXISTING DEVICE AND LIGHT FIXTUREQUANTITIES AND LOCATIONS WERE TAKENFROM EXISTING DRAWINGS AND SITEOBSERVATIONS. CONTRACTOR SHALL FIELDVERIFY ALL DEVICES AND CIRCUITING.

3 WHEN REMODELING WORK INTERFERES WITHCIRCUITS THAT WOULD OTHERWISE BEUNTOUCHED, CONTRACTOR SHALL REWORKCIRCUITS AS REQUIRED.

KEY NOTES

E6 EXISTING DURESS STATION TO BE REMOVED.EXTEND CONDUIT AND CONDUCTORS TO NEWDURESS BUTTON.

E7 EXISTING ANNUCIATOR PANEL TO BERELOCATED TO OTHER SIDE OF PANEL.

7/15/2020

Page 26: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

2 3 4 5 6 7 8 9

10

9.48.98.2

G

H

I

1.5

D

E

F

OFFICE

H025

OFFICE

H022

OFFICE

H021

OFFICE

H020

TOILET

H024

BREAK ROOM

H023

COMMONELECT

H017

HOLDING

H036

FEMALELOCKER RM

H013A

FEMALES

H013

MALES

H014

MALELOCKER RM

H014A

COURT ROOM

H035

ACA

H028

RECEPTION

H001

OFFICE

H002

OFFICE

H003

OFFICE

H004

OFFICE

H005

OFFICE

H006

STORAGE

H007

OFFICE

H008

CONFERENCEROOM

H009

COMPUTERROOM

H010

TELEPHONEROOM

H011

BREAK ROOM

H012

STORAGE

H027

STORAGE

H029

MAIL ROOM

H030

OFFICE

H031

CORRIDOR

H000

OFFICE

I038

OFFICE

I039

ELECTRICALROOM

I040

TELECOMROOM

I041

MENS TOILET

I042

WOMENSTOILET

I043

WOMENS

I003

MENS

I002

VESTIBULE

H037

LOBBY

I001

VESTIBULE

I000

LOBBY

I000A

SECURITYOFFICE

I001A

CELL 1

I011

CELL 2

I012

CELL 3

I013

CELL 4

I014

CELL 5

I015

CELL 6

I016

CELL 7

I017

CELL 8

I018

CELL 9

I019

JANITORS

I020

MEDICALINTERVIEW

I021

MEDICALINTERVIEW

I022

JANITORS

I023

INTOX

I024

INTOX

I025

SALLYPORT

I026

INMATEWAITING

I010

INTEERVIEW

I027

INTERVIEW

I028

INTAKE LOBBY

I029

INTERVIEW

I030

INTERVIEW

I031

INTAKE

I037

STORAGE

I033

BRIEFING

I034

BREAK ROOM

I035

TOILET

I036

MENSPROCESS

I008

WOMENSPROCESS

I009

INTERVIEW

I046

INTERVIEW

I047INMATEWAITING

I044Room

I049

JUDGESCHAMBER

H034

CLERK

H032

TOILET

H033

SALLYPORT

I053

OFFICE

I007

CITY ID

I045

SALLYPORT

I004

VEST

I004A

CORRIDOR

H036A

(R)

(R)

(R)

(R)

(R)

(R)

(R)(R)

(R)(R)

(R) (R)

(R)

(R)

(R)

(R)

(R) (R)

(R)

(R)

(R)

(R)(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R)

(R) (R)

(R)(R)

(E)(E)

(E)(E)

(E)

(E)

(E) (E)

(E)

(E)

(E)

(E)

(E)

(E) (E)

(E)

(E)

(E)

(E)

(E)

(E)

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

9:3

9 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

LIGHTINGDEMOLITIONPLAN

ED2.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

1/8" = 1'-0"1 LIGHTING -DEMOLITION

GENERAL NOTES - DEMOLITION

1 ALL ELECTRICAL DEVICES AND LIGHT FIXTURESSHOWN DASHED AND TAGGED "(R)" ARE TO BEDISCONNECTED AND REMOVED, INCLUDING ALLASSOCIATED CONDUIT AND CONDUCTORS BACKTO THE SOURCE OR LAST DEVICE TO REMAINACTIVE. MAINTAIN CONTINUITY FOR EXISTINGDEVICES TO REMAIN.

2 EXISTING DEVICE AND LIGHT FIXTUREQUANTITIES AND LOCATIONS WERE TAKENFROM EXISTING DRAWINGS AND SITEOBSERVATIONS. CONTRACTOR SHALL FIELDVERIFY ALL DEVICES AND CIRCUITING.

3 WHEN REMODELING WORK INTERFERES WITHCIRCUITS THAT WOULD OTHERWISE BEUNTOUCHED, CONTRACTOR SHALL REWORKCIRCUITS AS REQUIRED.

KEY NOTES

7/15/2020

Page 27: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

G

GG

G

G

2

22

R

RR

D DR

J

JJ

TO

TO

2 3 4 5 6 7 8 9

10

9.48.98.2

G

H

I

1.5

D

E

F

OFFICE

H025

OFFICE

H022

OFFICE

H021

OFFICE

H020

TOILET

H024

BREAK ROOM

H023

COMMONELECT

H017

HOLDING

H036

COMMANDSTAFF LKR RM

H037A

FEMALELOCKER RM

H013A

FEMALES

H013

MALES

H014

MALELOCKER RM

H014A

COURT ROOM

H035

ACA

H028

RECEPTION

H001

OFFICE

H002

OFFICE

H003

OFFICE

H004

OFFICE

H005

OFFICE

H006

STORAGE

H007

OFFICE

H008

CONFERENCEROOM

H009

COMPUTERROOM

H010

TELEPHONEROOM

H011

BREAK ROOM

H012

STORAGE

H027

STORAGE

H029

MAIL ROOM

H030

OFFICE

H031

CORRIDOR

H000

OFFICE

I038

OFFICE

I039

ELECTRICALROOM

I040

TELECOMROOM

I041

MENS TOILET

I042

WOMENSTOILET

I043

WOMENS

I003

MENS

I002

VESTIBULE

H037

LOBBY

I001

VESTIBULE

I000

LOBBY

I000A

SECURITYOFFICE

I001A

CELL 1

I011

CELL 2

I012

CELL 3

I013

CELL 4

I014

CELL 5

I015

CELL 6

I016

CELL 7

I017

CELL 8

I018

CELL 9

I019

JANITORS

I020

MEDICALINTERVIEW

I021

MEDICALINTERVIEW

I022

JANITORS

I023

INTOX

I024

INTOX

I025

SALLYPORT

I026

INMATEWAITING

I010

INTEERVIEW

I027

INTERVIEW

I028

INTAKE LOBBY

I029

INTERVIEW

I030

INTERVIEW

I031

INTAKE

I037

STORAGE

I033

BRIEFING

I034

BREAK ROOM

I035

TOILET

I036

MENSPROCESS

I008

WOMENSPROCESS

I009

INTERVIEW

I046

INTERVIEW

I047INMATEWAITING

I044Room

I049

JUDGESCHAMBER

H034

CLERK

H032

TOILET

H033

SALLYPORT

I053

OFFICE

I007

CITY ID

I045

SALLYPORT

I004

VEST

I004A

CORRIDOR

H036A

(E)

L1C

ELC

L1C3

ELC2

(E)

(E)

(E)

(E)

L1C-12

L1C-56

L1C-58

E5

E3 E2

E1

E1

E1

(N)

(N)

(N)

(N)

(N) (N)(N)(N)

(N)

(N)

(N)

(N)

(N)

L1C3-11

E4

1

EF

2

EF

L1C3-12

E7

(E)(E)

(E) (E)

(E)

(E)

(E) (E)

(E)

(E) (E)

(E)

(E)

(E)

(E)

(E) (E)

(E)

(E)

(N)

(N)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E) (E)

(E)

(E)

(E)

(E)(E)(E)

(E)

(E)

(E)

(E)

(E)(E)(E)

(E)

(E)

(E) (E)

(E)

(E)

(TYP. OF 3)

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

9:2

7 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

ELECTRICALFLOOR PLAN

E1.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

1/8" = 1'-0"1 POWER -NEW WORK

GENERAL NOTES - POWER

1 ELECTRICAL CONTRACTOR SHALL COORDINATEEXACT LOCATION OF ALL MECHANICAL ANDPLUMBING EQUIPMENT WITH MECHANICAL ANDPLUMBING CONTRACTORS. REFER TOMECHANICAL AND PLUMBING EQUIPMENTSCHEDULES FOR ALL ELECTRICALCONNECTIONS.

2 ALL EXPOSED CONDUIT SHALL BE ROUTEDPERPENDICULAR, PARALLEL, AND TIGHT TOCOLUMNS AND BEAMS. ALL EXPOSED CONDUITROUTING SHALL BE COORDINATED WITHENGINEER AND ARCHITECT PRIOR TOINSTALLATION. NO ADDITIONAL COST TOOWNER WILL BE ALLOWED FOR RELOCATINGCONDUIT DUE TO THE LACK OF COORDINATIONWITH ARCHITECT.

3 ALL BACK BOXES SHALL BE FLUSH MOUNTEDUNLESS OTHERWISE NOTED. ALL VERTICALSECTIONS OF CONDUIT SHALL BE CONCEALED.CONTRACTOR SHALL COORDINATEINSTALLATION OF CONDUIT AND BACK BOXES INCONCRETE, MASONARY AND GYP. WALLS.

4 COORDINATE ALL FLOOR BOX LOCATIONS WITHARCHITECT AND LOW VOLTAGE CONTRACTORPRIOR TO INSTALLATION.

5 PROVIDE TAMPER RESISTANT RECEPTACLES INAPPLICABLE LOCATIONS AS DEFINED IN NFPA 70(2017) ARTICLE 406.12.

KEY NOTES

E1 ROUGH-IN FOR CARD READER. COORDINATEHEIGHT WITH ARCHITECT PRIOR TO ROUGH-IN.

E2 NEW REMOTE DOOR RELEASE BUTTON.

E3 NEW DURESS BUTTON, EXTEND ANDCONNECT TO EXISTING DURESS SYSTEM.COORDINATE EXACT CONNECTIONREQUIREMENTS WITH EXISTING SYSTEM.

E4 POWER CONNECTION TO DOOR HARDWARE.

E5 PROVIDE NEW POWER POLE WITH (2) DUPLEXOUTLETS.

E7 EXISTING ANNUCIATOR PANEL TO BERELOCATED TO OTHER SIDE OF PANEL.

7/15/2020

Page 28: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

REF.

3

3

3

3

2 3 4 5 6 7 8 9

10

9.48.98.2

G

H

I

1.5

D

E

F

OFFICE

H025

OFFICE

H022

OFFICE

H021

OFFICE

H020

TOILET

H024

BREAK ROOM

H023

COMMONELECT

H017

HOLDING

H036

COMMANDSTAFF LKR RM

H037A

FEMALELOCKER RM

H013A

FEMALES

H013

MALES

H014

MALELOCKER RM

H014A

COURT ROOM

H035

ACA

H028

RECEPTION

H001

OFFICE

H002

OFFICE

H003

OFFICE

H004

OFFICE

H005

OFFICE

H006

STORAGE

H007

OFFICE

H008

CONFERENCEROOM

H009

COMPUTERROOM

H010

TELEPHONEROOM

H011

BREAK ROOM

H012

STORAGE

H027

STORAGE

H029

MAIL ROOM

H030

OFFICE

H031

CORRIDOR

H000

OFFICE

I038

OFFICE

I039

ELECTRICALROOM

I040

TELECOMROOM

I041

MENS TOILET

I042

WOMENSTOILET

I043

WOMENS

I003

MENS

I002

VESTIBULE

H037

LOBBY

I001

VESTIBULE

I000

LOBBY

I000A

SECURITYOFFICE

I001A

CELL 1

I011

CELL 2

I012

CELL 3

I013

CELL 4

I014

CELL 5

I015

CELL 6

I016

CELL 7

I017

CELL 8

I018

CELL 9

I019

JANITORS

I020

MEDICALINTERVIEW

I021

MEDICALINTERVIEW

I022

JANITORS

I023

INTOX

I024

INTOX

I025

SALLYPORT

I026

INMATEWAITING

I010

INTEERVIEW

I027

INTERVIEW

I028

INTAKE LOBBY

I029

INTERVIEW

I030

INTERVIEW

I031

INTAKE

I037

STORAGE

I033

BRIEFING

I034

BREAK ROOM

I035

TOILET

I036

MENSPROCESS

I008

WOMENSPROCESS

I009

INTERVIEW

I046

INTERVIEW

I047INMATEWAITING

I044Room

I049

JUDGESCHAMBER

H034

CLERK

H032

TOILET

H033

SALLYPORT

I053

OFFICE

I007

CITY ID

I045

SALLYPORT

I004

VEST

I004A

CORRIDOR

H036A

A A

A

AEM

A A

A

AEM

A

A

AEM

A

A

A

A

AEM

A

A

AEM

A

AEM

AEMA A

A

A

L2

L2

B

B

C C

C1 C

L1

L1

L1 L1

L1L1

L3

L3L3

L3

L3

L3

L3

(E)(E)

(E)(E)

(E)

(E)

(E) (E)

(E)

(E)

(E)

(E)

(E)

(E) (E)

(E)

(E)

(E)

(E)

(E)

(E)

L4

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

9:3

1 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

LIGHTING PLAN

E2.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

1/8" = 1'-0"1 LIGHTING -NEW WORK

GENERAL NOTES - LIGHTING

1 REFER TO SHEET E6.2 FOR LIGHT FIXTURESCHEDULE.

2 REFER TO ARCHITECTURAL REFLECTED CEILINGPLANS FOR ALL FIXTURE LOCATIONS WITHIN ACEILING OR CEILING GRID. FOR AREAS WITHOUTCEILINGS, FIXTURE LOCATIONS AREDIAGRAMMATIC. THE INTENT IS TO ALIGN,CENTER, OR SPACE FIXTURES BETWEENARCHITECTURAL AND STRUCTURAL ELEMENTS.

3 ALL SURFACE MOUNTED CONDUIT SHALL BEROUTED PERPENDICULAR AND PARALLEL TOBEAMS AND COLUMNS. ALL CONDUIT ROUTINGSHALL BE COORDINATED WITH THE ARCHITECTPRIOR TO INSTALLATION AND INSTALLED IN ANEAT AND CONSISTENT MANNER. ALL SURFACEMOUNTED CONDUIT WHERE EXPOSED TOPUBLIC AREAS SHALL BE PAINTED. PAINT COLORTO BE DETERMINED BY THE ARCHITECT.

4 ELECTRICAL CONTRACTOR SHALL FIELD VERIFYEXACT FIXTURE LENGTHS FOR ALL CONTINUOUSLINEAR FIXTURES. FOR COVES, PROVIDECONTINUOUS ILLUMINATION WITH 6" MAXIMUMDISTANCE BETWEEN END OF FIXTURE ANDWALL.

5 ELECTRICAL CONTRACTOR TO COORDINATEWITH MECHANICAL CONTRACTOR FORPLACEMENT OF FIXTURES WITHIN MECHANICALROOMS.

6 PROVIDE AN UN-SWITCHED, AND NOT RELAYCONTROLLED, HOT CONDUCTOR TO EACH EXITSIGN AND EMERGENCY BATTERY PACK.

7 COORDINATE EXACT LOCATIONS ANDQUANTITIES OF OCCUPANCY SENSORS WITHMANUFACTURERS RECOMMENDATIONS FORCOVERAGE AND REQUIRED DISTANCES FROMHVAC DIFFUSERS.

8 DOCUMENTATION PER 408.3.2 2015 IECC WILL BEPROVIDED.

KEY NOTES

L1 DIRECTLY REPLACE EXISTING FIXTURE WITHNEW. RECONNECT TO EXISTING LIGHTINGCIRCUIT AND CONTROLS.

L2 CONNECT NEW SWITCHES TO EXISTING LIGHTFIXTURES.

L3 CONNECT FIXTURE TO EXISTING EMERGENCYCIRCUIT EHC-3. LOAD ON CIRCUIT INCREASEDBY 230 VA. PROVIDE A UL-824 PLENUM RATEDDIMMING EMERGENCY LIGHTING CONTROLUNIT(S) AS REQUIRED (WATTSTOPPERELCU-200 OR EQUAL) AND SWITCH WITHNORMAL LIGHTS SERVING AREA.

L4 CONNECT TO EXISTING LIGHTING CIRCUITSERVING AREA. TOTAL LOAD ON CIRCUITREDUCED BY 972 VA.

7/15/2020

Page 29: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

EXISTING UTILITY TRANSFORMER

TO UTILITY

SPD

100A3P1

4000A/3P

1200A3P2

H1C H1D

2000A/3P

2000A208/120V, 3PH, 4WEXISTING

4000A MCB480Y/277V, 3PH, 4WEXISTING

G

G

N

(E) 3/0 GND

PROVIDE CONCRETE PAD

10 SETS - 4#600 KCMIL, 4"C

METERING CT'S AND VT'S LOCATED IN SECONDARY COMPARTMENT OF PAD MOUNTED TRANSFORMER

L1C

45KVA480-208/120V

L1D

30KVA480-208/120V

60AF60AS

125AF200AS

125AF200AS

ONLY PART OF SWITCHBOARD IS SHOWN

ONLY PART OF SWITCHBOARD IS SHOWN

(4-250 KCMIL) 2-1/2"C

(4#1) 1-1/2"C(4#4) 1-1/4"C

(4#1/0,1#6G) 2"C

(3#3,1#6G) 1-1/2"C

(4#2,1#8G) 1-1/4"C

4 SETS - 3#350 KCMIL, 1#4/0G, 3-1/2"C

L1C3

100A3P250A3P

100A3P

REVISED LOADS ON EXISTING PANELS

GENERAL NOTES:

DOOR DETAIL INDICATES DOOR HANDLE OR CRASHBAR ON SECURED SIDE OF DOOR FOR REFERENCE ONLY. REFER TO DOOR HARDWARE DIVISION SPECIFICATIONS FOR ACTUAL HARDWARE INFORMATION.

LOCK POWER WILL VARY DEPENDING ON LOCK TYPE AND DOOR HARDWARE. REFER TO SECURITY SCHEDULES FOR COORDINATED POWER REQUIREMENTS. CONTRACTOR SHALL CROSS REFERENCE WITH OFFICIAL DOOR HARDWARE SCHEDULE/SPECIFICATIONS TO CONFIRM FINAL REQUIREMENTS.

1.

2.

DOOR MONITOR: PROVIDE FLUSH MOUNTED DOOR STATUSMONITOR.

DOOR MONITOR CONDUIT: PROVIDE 3/4"C. (19mm) FROM DOOR FRAME TO J-BOX.

READER/KEYPAD: PROVIDE 4"X4"X2-1/8" (1OOmmX100mmX54mm) BACK-BOX AND SINGLE GANG MUD RING MOUNTED ON NON-SECURED SIDE OF DOOR AT 42" AFF. (WITH READER)

READER/KEYPAD CONDUIT: PROVIDE 3/4"C. (19mm) TO J-BOX.

SECURITY J-BOX: PROVIDE 8"X8"X4" (200mmX200mmX100mm) J-BOX FLUSH MOUNTED ABOVE FINISHED ACCESSIBLE CEILING ON SECURED SIDE OF DOOR.

SECURITY J-BOX CONDUIT: PROVIDE 1"C. (25mm) TO NEAREST COMM ROOM OR CABLE TRAY, U.N.O. ON LEGEND.

LOCKING HARDWARE CONDUIT: PROVIDE 3/4"C. (19mm) FROM DOOR FRAME TO J-BOX. COORDINATE FRAME TIE-IN LOCATION WITH DOOR HARDWARE DIVISION.

ELECTRIC LOCKSET: ELECTRIFIED LOCK AND HINGE, SHOWN FOR REFERENCE ONLY. (REFER TO DOOR HARDWARE DIVISION FOR ADDITIONAL INFO.)

ELECTRIC STRIKE: ELECTRIFIED STRIKE, SHOWN FOR REFERENCE ONLY. (REFER TO DOOR HARDWARE DIVISION FOR ADDITIONAL INFO.)

ELECTROMAGNETIC LOCKS: SURFACE MOUNTED ELECTROMAGNETIC LOCK, SHOWN FOR REFERENCE ONLY. (REFER TO DOOR HARDWARE DIVISION FOR ADDITIONAL INFO.)

PIR MOTION REX: PROVIDE MOTION "REX" DEVICE CENTERED AND MOUNTED TO TOP OF DOOR FRAME. ROUTE CABLING INTO DOOR FRAME AND UP TO J-BOX.

PUSH BUTTON REX: WHERE APPLICABLE (PER DRAWINGS / SCHEDULES) PROVIDE PUSH BUTTON "REX" MOUNTED ON SECURED SIDE OF DOOR AT 42" AFF WITH 4"X4"X2-1/8" (100MMX100MMX54MM) BACK-BOX, SINGLE GANG FACEPLATE AND 3/4"C UP TO SECURITY J-BOX.

KEY NOTES:

1

2

3

4

5

6

7

8

9

CARD-IN WITH CONTACTS, FREE EXIT, PIR MOTION REX, PUSH BUTTON REX (WHERE APPLICABLE)

6

5

7

4

3

3

9

8

10

7

2

11

1

R

10

11

12

GENERAL NOTES:

FURNITURE AND/OR MILLWORK IS SHOWN HERE FOR REFERENCE ONLY. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION AND TO COORDINATE FINAL DEVICE PLACEMENT PRIOR TO INSTALLATION.

1.

DURESS BUTTON: PROVIDE SURFACE MOUNTED DURESS BUTTON UNDER FRONT EDGE OF COUNTER, DESK OR TABLE.

FLEXIBLE CONDUIT WHIP: PROVIDE 3/4" FLEXIBLE WHIP FROM DURESS BUTTON TO J-BOX LOCATED BELOW COUNTER, DESK OR TABLE.

DURESS BUTTON J-BOX: PROVIDE 4"X4"X2-1/8" (100mmX100mmX 54mm) BACK-BOX AND SINGLE GANG FACE PLATE FLUSH MOUNTED IN WALL BELOW COUNTER, DESK OR TABLE AT 24" AFF.

DURESS BUTTON CONDUIT: PROVIDE 3/4"C. (19mm) FROM J-BOX TO NEAREST ACCESSIBLE CEILING, CABLE TRAY, OR COMM ROOM.

KEY NOTES:

3

1

2

3

4

1

2

4

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

9:3

1 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

ELECTRICALONE-LINEDIAGRAM

E6.1

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

NO SCALE1

EXISTING ONE-LINE DIAGRAM

NO SCALE2

CARD ACCESS - SINGLE DOOR

NO SCALE3

DURESS BUTTON - UNDER DESK OR TABLE

ALL EQUIPMENT, DEVICES AND FEEDERS SHOWN ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED.

7/15/2020

Page 30: CRIMINAL JUSTICE CENTER - admin.elpasoco.com

© D

LR

Gro

up

REVISIONS

7/1

5/2

020

1:4

9:3

2 P

M

BIM

36

0://3

7-2

01

11-0

1 C

rim

ina

l Justice C

en

ter/

37-2

01

11

-01

_C

rim

inalJ

usticeC

en

ter_

ME

P_

20

20.r

vt

Project Number

07/15/2020

EL P

AS

O C

OU

NT

Y -

CR

IMIN

AL J

US

TIC

E C

EN

TE

R

100%CONSTRUCTIONDOCUMENTS

ELECTRICALSCHEDULES

E6.2

2739 E

. LA

S V

EG

AS

ST

,C

OLO

RA

DO

SP

RIN

GS

, C

O 8

0906

LO

BB

Y A

ND

LO

CK

ER

RO

OM

RE

NO

VA

TIO

N

7/15/2020

TOTAL LOAD 68.77 190.9

KITCHEN LOADS * 0%2. PROVIDE NEW BREAKER MATCH EXISTING.

(RECEPTACLE LOADS - 10KVA) * 50% -5.08 -14.11. REVISED LOAD ON CIRCUIT MADE SPARE.

LARGEST MOTOR LOAD * 25% 0.24 0.7NOTES:

LONG CONTINUOUS LOADS * 25% 0.75 2.1

TOTAL CONNECTED LOAD 72.86 202.2

KVA AMPS * ALL LOADS ARE EXISTING U.O.N.

OPTIONS:

199.6 192.1 215.5 AMPS

TOTAL CONNECTED PHASE LOAD 23952 23048 25860 VA

83 - - - 720 20A/1P R CLASSIFICATION & ID NORTH 84

81 - - - 720 20A/1P R CLASSIFICATION SOUTH 82

79 LIEBER AIR CONDITIONER EQ 100A/3P 720 20A/1P R INTAKE CUBICLE POWER POLE 80

77 - - - 2000 400 20A/1P EQ ELECTRIC RM FIBER OPTIC 78

75 - - - 2000 - - - 76

73 LEE TEMP CONDENSERS EQ 30A/3P 2000 - - - 74

71 SCANNER (ISLAND) EQ 20A/1P 800 20A/3P TVSS 72

69 REC - RMS 1009-1010 R 20A/1P 720 720 20A/1P R REC - INMATE CLASS 70

67 COMP. OUTLETS - ISLAND EQ 20A/1P 800 720 20A/1P R REC - INMATE CLASS 68

65 POWER POLE PRINTERS EQ 20A/1P 1000 720 20A/1P R REC - INMATE CLASS 66

63 LEE TEMP RECIEVER TANK EQ 20A/1P 800 720 20A/1P R REC - EAST INTAKE 64

61 LTG - CANS OVER PASS CTR LT 20A/1P 500 1000 20A/1P EQ POWER POLE - INTAKE PRINTER 62

59 HT TRACE EQ 20A/1P 500 1000 20A/1P EQ COFFEE - WEST INTAKE 60

57 P-4 M 20A/1P 696 200 20A/1P EQ KIOSK 58 2

55 HT TRACE EQ 20A/1P 500 720 20A/1P EQ REC - SECURITY OFFICE 56 2

53 REC R 20A/1P 720 1200 20A/1P EQ WASHER 54

51 RECEPT - FRONT OF CELLS R 20A/1P 720 360 20A/1P EQ TELE. 52

49 REC R 20A/1P 720 720 20A/1P R REC 50

47 COPIER EQ 20A/1P 1000 720 20A/1P R REC 48

45 REC - FLAG POLE SALLY PORT R 20A/1P 720 720 20A/1P R REC 46

43 REC R 20A/1P 720 720 20A/1P R REC 44

41 EXISTING LOAD EQ 20A/1P 1000 936 - - - 42

39 - - - 3300 936 - - - 40

37 - - - 4000 936 15A/3P EQ CONVEYOR 38

35 L1C3 P 100A/3P 3548 936 - - - 36

33 - - - 1000 936 - - - 34

31 DRYER EQ 20A/2P 1000 936 15A/3P EQ CONVEYOR 32

29 - - - 1000 1000 20A/1P EQ 4-PLUGS FOR FLOOR BUFF 30

27 COPIER EQ 20A/2P 1000 720 20A/1P R REC ADMIN 28

25 MICROWAVE EQ 20A/1P 1000 720 20A/1P R BREAK ROOM 26

23 COFFEE EQ 20A/1P 1000 720 20A/1P R REC ADMIN 24

21 REFRIGERATOR EQ 20A/1P 1000 720 20A/1P R REC ADMIN - CITY ID 22

19 VENDING EQ 20A/1P 1000 720 20A/1P R REC ADMIN - WOMEN RR 20

17 VENDING EQ 20A/1P 1000 720 20A/1P R REC ADMIN - MENS RR 18

15 VENDING EQ 20A/1P 1000 720 20A/1P R REC ADMIN 16

13 VENDING EQ 20A/1P 1000 720 20A/1P R REC ADMIN - COURT RM 14

11 VENDING EQ 20A/1P 1000 1000 20A/1P EQ X-RAY & METAL DETECTOR 12 1

9 VENDING EQ 20A/1P 1000 400 20A/1P EQ FIRE ANNUCIATION PANEL 10

7 LTG LT 20A/1P 500 720 20A/1P R REC ADMIN (ATM FRONT LOBBY) 8

5 LTG LT 20A/1P 500 720 20A/1P R REC ADMIN 6

3 LTG LT 20A/1P 500 720 20A/1P R REC ADMIN 4

1 LTG - ENTRY SOFFIT LT 20A/1P 500 360 20A/1P EQ QUAD - NEW PHONE BOARD 2

N # DESCRIPTION TYPE BRKR PHASE A PHASE B PHASE C BRKR TYPE DESCRIPTION # N

VA

RATING: 10K AIC 250A BUS

MOUNTING: SURFACE 250A MCB

LOCATION: ELEC RM I040 208Y/120V, 3PH-4W+GND

EPC CJC REMODEL L1C M-E ENGINEERS, INC.

7/15/2020

TOTAL LOAD 11.21 31.1

KITCHEN LOADS * 0%

(RECEPTACLE LOADS - 10KVA) * 50%1. PROVIDE NEW BREAKER, MATCH EXISTING.

LARGEST MOTOR LOAD * 25% 0.24 0.7NOTES:

LONG CONTINUOUS LOADS * 25% 0.13 0.3

TOTAL CONNECTED LOAD 10.85 30.1

KVA AMPS * ALL LOADS ARE EXISTING U.O.N.

OPTIONS:

33.3 27.5 29.6 AMPS

TOTAL CONNECTED PHASE LOAD 4000 3300 3548 VA

41 SPACE SPACE 42

39 SPACE SPACE 40

37 SPACE SPACE 38

35 SPACE SPACE 36

33 SPACE SPACE 34

31 SPACE SPACE 32

29 SPACE SPACE 30

27 SPACE SPACE 28

25 SPACE SPACE 26

23 SPACE SPACE 24

21 SPACE SPACE 22

19 SPACE SPACE 20

17 SPACE SPACE 18

15 SPACE SPACE 16

13 SPACE SPACE 14

1 11 LOBBY - DOOR HARDWARE EQ 20A/1P 600 948 20A/1P M LOCKER ROOM EF-1 & EF-2 12 1

9 LTG - TRACK LOBBY AREA LT 20A/1P 500 800 20A/1P EQ EXISTING LOAD 10

7 - - - 1000 1000 - - - 8

5 EXISTING LOAD EQ 20A/2P 1000 1000 20A/2P EQ EXISTING LOAD 6

3 - - - 1000 1000 - - - 4

1 EXISTING LOAD EQ 20A/2P 1000 1000 20A/2P EQ EXISTING LOAD 2

N # DESCRIPTION TYPE BRKR PHASE A PHASE B PHASE C BRKR TYPE DESCRIPTION # N

VA

RATING: 10K AIC 100A BUS

MOUNTING: SURFACE MLO

LOCATION: ELEC RM I040 208Y/120V, 3PH-4W+GND

EPC CJC REMODEL L1C3 M-E ENGINEERS, INC.

(EXISTING PANEL) (EXISTING PANEL)

TOTAL LOAD ADDED TO PANEL IS 1824 VA (5.1 AMPS AT 208V-3P)

TOTAL LOAD REMOVED FROM PANEL IS 1224 VA (3.4 AMPS AT 208V-3P)

LIGHTING FIXTURE SCHEDULEFIXTURE

TYPE MANUFACTURER SERIES

LAMP INFORMATION INPUT

WATTS VOLTAGE MOUNTING DESCRIPTIONTYPE

A COLUMBIALITHONIAMETALUX

LJT24GTL24

24GRLED

LED3500K

34 VA 277 V RECESSED - 2X4 LED TROFFER- MINIMUM 4,000 LUMENS OUTPUT- #12 PATTERN ACRYLIC LENS- FLUSH WHITE STEEL DOOR

AEM COLUMBIALITHONIAMETALUX

LJT24GTL24

24GRLED

LED3500K

34 VA 277 V RECESSED - SAME AS TYPE 'A' EXCEPT ON EMERGENCY GENERATOR CIRCUIT

B PRESCOLITEHALO

LITHONIA

LFS6SLPD6

LDN6

LED3500K

16 VA 277 V RECESSED - 6" LED OPEN DOWNLIGHT- SEMI-DIFFUSE CLEAR ALZAK REFLECTOR- 1500 LUMEN MODULE- 0-10V DIMMING DRIVER

C COLUMBIALITHONIAMETALUX

LCL4SNLED

ZL1N

LED3500K

42 VA 277 V MOUNTED IN COVE - 4' LENGTH LED STRIPLIGHT- MEDIUM LUMEN OUTPUT (~5300 LUMENS)- FIXED OUTPUT DRIVE- MOUNTED IN EXISTING COVE

C1 COLUMBIALITHONIAMETALUX

LCL4SNLED

ZL1N

LED3500K

21 VA 277 V MOUNTED IN COVE - SAME AS TYPE 'C' EXCEPT 2' IN LENGTH

-1.7 KW

LOAD ON SERVICE WAS REDUCED BY -4.7 AMPS

LOAD ADDED BY NEW WORK + 2.2 AMPS

LOAD TO BE REMOVED BY DEMO WORK: - 6.9 AMPS

LOAD CALCULATION FOR EXISTING SERVICE 480Y/277V, 3 PHASE, 4 WIRE, 4000A SERVICE

7/15/2020