crl esk1/esp1 - c.r. laurence co., inc.crl esk1/esp1 electric strike keeper or sinle doors 03...

11
11M0255 INSTALLATION INSTRUCTIONS CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER FOR SINGLE DOORS ALUMINUM Phone: (800) 421-6144 • Fax: (800) 587-7501 crlaurence.com • usalum.com • crl-arch.com NOTE: Sensor feature available on ESP Strikes only.

Upload: others

Post on 13-Jul-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

11M0255

INSTALLATION INSTRUCTIONS

CRL ESK1/ESP1ELECTRIC STRIKE KEEPER

FOR SINGLE DOORS

ALUMINUM

Phone: (800) 421-6144 • Fax: (800) 587-7501crlaurence.com • usalum.com • crl-arch.com

NOTE: Sensor feature available on ESP Strikes only.

Page 2: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

02crlaurence.com | usalum.com

ORDER OF ASSEMBLY AND INSTALLATION

INTRODUCTION/TOOLS REQUIRED ............................................................................................................. 03

PARTS IDENTIFICATION.................................................................................................................................. 04

HEADER PREPARATION 05 - 06

ELECTRIC STRIKE APPLICATIONS ................................................................................................................ 07

ESK1/ESP1 ELECTRIC STRIKE INSTALLATION 08 - 11

VOLTAGE AND WIRING .............................................................................................................................. 08

ELECTRIC STRIKE ATTACHMENT ............................................................................................................ 09

ELECTRIC STRIKE ADJUSTMENT ............................................................................................................ 10

RE-ATTACH STRIKE COVER AND MAKE FINAL ADJUSTMENTS .......................................................... 11

The rapidly changing technology within the architectural aluminum products industry demands that C.R. Laurence/U.S. Aluminum reserve the right to revise, discontinue, or change any product line, specification, or electronic media without prior written notice.

NOTE: Dimensions in parentheses ( ) are millimeters unless otherwise noted.

Page 3: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

03crlaurence.com | usalum.com

INTRODUCTIONESK1/ESP1 ELECTRIC STRIKE KEEPER

• Designed for use with 1/2" or 3/4" (12.7 or 19) tempered glass doors.

• Used in conjunction with CRL glass door Panic and Deadbolt Handles.

• Fail secure. (Fail safe optional)

• Latch/Deadbolt Monitor (ESP Strikes only)

This Electric Strike Keeper satisfies the following safety standards: a. American National Standards Institute (ANSI/BHMA) i. A117.1 Providing Accessibility and Usability for Physically Handicapped People ii. A156.3 Exit Devices iii. A156.18 Materials and Finishes b. Americans with Disabilities Act (A.D.A.) c. American Society for Testing and Materials (ASTM) d. National Fire Protection Association (NFPA 101) e. Underwriters Laboratory (UL) i. 305 Panic Hardware

Tools RequiredDrill bits: 1/4" Taps: 5/16-18Tape MeasureSaw HorsesCordless Drill Phillips Head Screwdriver1/4" and 3/16" Hex Keys3/4" Masking Tape

Center PunchFlat Metal File Round Metal FileJigsaw with Metal Cutting Blade Stepladder Framing Square/Straight EdgeESP040 Adjustable Gauge (Ordered Separately)

FEATURES

NOTE: Any modifications, other than those specified in this document, could result in this product's failure to meet UL safety ratings and void the manufacturer's warranties.

Page 4: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

04crlaurence.com | usalum.com

PARTS LISTCALL OUT QTY PART PART NO. DESCRIPTION

2 ESK015/16-18 x 1" SHCS

Stop Screw for Rail Mount Doors (Bumper Sold Separately)

2 ESK025/16-18 x 1" SHCS

Stop Screw for Glass Mount Doors (Bumper Sold Separately)

2 BMPRBR Rubber Bumper for Strike

D

E

FASTENERS AND PARTS LIST

CALL OUT QTY. FASTENER FASTENER

DESCRIPTION PART USED WITHPART NUMBER

2 5/16-18 x 3/4" SHCS

ESK1/ESP1 Electric Strike Keeper

for Single Door

2 10-32 x 1/2" FHMS

Electric Strike Cover (Included with ESK1/ESP1)

2 1/4-20 x 1/2" SHCS

ESK1/ESP1 Electric Strike Keeper

for Single Door

PARTS IDENTIFICATION

A

B

C

F

Page 5: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

05crlaurence.com | usalum.com

NOT TO SCALE

HEADER PREPARATION

1. Place the header horizontally on the work surface, interior side up. 2. Mark the centerlines and the layout on the header as shown in. (Fig. 1)

REMOVE HEADER AND PREPARE PER ATTACHED TEMPLATE

INTERIOR

FIG. 1

Drill and Tap 5/16-18 x 3/4" UNC (2) Places

Centerline of Pivot

4-1/8" (104.8) to Leading Edge-Swing 3 This Side4-1/8" (104.8) to Leading Edge-Swing 4 This Side

1" (25.4) on 1/2" (12.7) Glass

1/4" (6.4) Centerline for 1/2" (12.7) Glass

1-1/8" (28.6) on 3/4" (19) Glass

3/8" (9.5) Centerline for 3/4" (19) Glass

Face of Glass

VIEW SHOWN FROM BELOW

EXTERIOR

R 1/8" (3) (Typ.)

3"(76)

3"(76.2)13/32"

(10.3)

1-13/32"(35.7)

1-5/32"(29.4) 29/32"

(23)29/32"(23)

11/16"(17.5)

1-13/16"(46)

1-9/32"(32.5)

6"(152.4)

3-15/16"(100)

Page 6: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

06crlaurence.com | usalum.com

NOT TO SCALE

HEADER PREPARATION (CONTINUED)

Interior Edge of Header

Use Template from Box

Drill and Tap for a (2) 5/16"-18 x 3/4" SHCS

REINSTALL THE PREPARED HEADER AND CONTINUE WITH THE ELECTRIC STRIKE INSTALLATION

Hardware Configuration

FIG. 2ESP SHOWN

Exterior Edge of Header

FIG. 3

Page 7: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

07crlaurence.com | usalum.com

NOT TO SCALE

FIG. 4DOOR RAIL MOUNTING

Folger Adam 310-1 Electric Strike with 3/4" (19) Straight Keeper

Adjustable Bolt/Stop

Electric Strike Parallel to Door

2 F.O.G.

Header

ELECTRIC STRIKE APPLICATIONS DOOR RAIL APPLICATION AND DIRECT TO GLASS APPLICATION

Adjustable Bolt/Stop

2 F.O.G.

DIRECT TO GLASS MOUNTINGFIG. 5

Header

FIG. 6

NOTE: Face of the Strike Keeper MUST be set at 87 degrees as illustrated in Figure 6. To adjust the Strike refer to page 10.

Electric Wires

Header

Face of the Strike Keeper factory preset at 87 degrees87º

Electric Strike Mounting Bolts

Folger Adam 310-1 Electric Strike with 3/4" (19) Straight Keeper

Door Stop Mounting Bolts

Door Stop Cover (included) Cover Retaining

Screw

D

Folger Adam 310-1 Electric Strike with 3/4" (19) Straight Keeper

EESK01 Rail Stop Screw

ESK02 Glass Stop Screw

3/16" (5) Gap

3/16" (5) Gap

Page 8: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

08crlaurence.com | usalum.com

NOT TO SCALE

ELECTRICAL RATINGS FOR SOLENOID

CONTINUOUS DUTY 24V DC

RESISTANCE IN OHMS 96

AMPS .25

MINIMUM GAGE REQUIREMENTS

300 FEET OR LESS 18 ga.

300 - 400 FEET 16 ga.

WIRE STANDARDSWIRE # COLOR USAGE

1 BLACK RETURN (–)

2 PURPLE 24V DC POWER

3 BLACK COM

4 RED NO

5 BLUE NC

ELECTRIC STRIKE

BOLT MONITOR SWITCH

FIG. 7

Strike Mechanism

Sensor

Purple Wire

Black Wire

Red Wire

Black WireBlue Wire

VOLTAGE AND WIRINGELECTRIC STRIKE ATTACHMENT

1. Before installing the strike, make the necessary wire connections. Refer to the table below in. (Fig. 7)

for ESK/ESP strikes.

for latch/deadbolt and monitor on ESP strikes only.

2. When you are installing the strike into the frame cut-out (Fig. 3, page 06), tuck the wiring away from the strike area to avoid pinching.

NOTE: Proper operating voltage must be supplied to the Strike for it to function correctly. Voltage must be within +10% of the required voltage that is listed on the Strike Label.

6A

6B

Specifications• Handle material: 1-1/4" (32) diameter Stainless Steel Tubing.• Switch, SPDT, maximum contact rating 5 Amps @ 250 Volts. • Watertight precision body. • 10 million cycle mechanism. • Meets with IP67 (IEC 529) requirements.

2

4

5

1

3

6A

6B

Page 9: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

09crlaurence.com | usalum.com

NOT TO SCALE

FIG. 8

FIG. 9

(2) 1/4-20 x 1/2" SHCS

Strike Mechanism

Face Plate

C

(2) 5/16-18 x 3/4"SHCS

A

ELECTRIC STRIKE ATTACHMENT (CONTINUED)1. Fasten the Electric Strike to the header using (2) 5/16-18 x 3/4" SHCS. (Fig. 8)

2. Check the horizontal alignment. Make sure that the centerline of the latch bolt is aligned with the centerline of the strike.

3. In case of misalignment, a 3/16" (4.8) horizontal adjustment may be made between the strike mechanism and the face plate. (Fig. 9)

A

Page 10: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

10crlaurence.com | usalum.com

*THIS IS REQUIRED ONLY IF: 1. Electric Strike is replaced. 2. The latch sensor gives a false reading when the door is pushed out while secured.To Adjust: A) Remove the (2) 5/16-18 x 3/4" SHCS. B) Remove the Strike from the header. (Fig.10) C) Loosen the (2) 1/4"-20 x 1/2" SHCS. D) Apply pressure to the Strike Keeper to create a gap. (Fig.11) E) Insert the ESP040 Electric Offset Jig while holding the Strike Keeper. (Fig.12) F) Push and hold the Strike Keeper in against the Jig and re-tighten the (2) 1/4"-20 x 1/2" SHCS. (Fig.13) G) Remove the ESP040 Electric Offset Jig. (Fig.14) H) Install the Electric Strike Assembly using the (2) 5/16-18 x 3/4" SHCS.

C

C

A

A

FIG. 14FIG. 13

FIG. 11 FIG. 12

Strike Keeper

ESP040 Electric Offset Jig ordered separately. Used only for the ESP Strikes

Strike Keeper

(2) 1/4"-20 x 1/2" SHCS

Strike Keeper

FIG. 10

(2) 5/16"-18 x 3/4" SHCS

C (2) 1/4"-20 x 1/2" SHCS

Strike Keeper

C

A

ESP040 Electric Offset Jig ordered separately. Used only for the ESP Strikes

ESP040 Electric Offset Jig ordered separately. Used only for the ESP Strikes

ELECTRIC STRIKE ATTACHMENT (CONTINUED)ELECTRIC STRIKE ADJUSTMENT

Page 11: CRL ESK1/ESP1 - C.R. Laurence Co., Inc.CRL ESK1/ESP1 ELECTRIC STRIKE KEEPER OR SINLE DOORS 03 INTRODUCTION ESK1/ESP1 ELECTRIC STRIKE KEEPER • Designed for use with 1/2" or 3/4" (12.7

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

11crlaurence.com | usalum.com

NOT TO SCALE

10-32 x 1/2" FHMS (2) Places

B

Allen Wrench

ELECTRIC STRIKE INSTALLATION (CONTINUED)RE-ATTACH STRIKE COVER AND MAKE FINAL ADJUSTMENTS

1. Install the Strike cover using (2) 10-32 x 1/2" FHMS. (Fig. 15)

2. When the door closes against the rubber stop pads, the retractable bolt should automatically move upward to engage the Strike.

3. If it does NOT engage, the door stops should be adjusted inward. Do not overtighten. This can cause the door to rattle. 4. To adjust the stop, remove the rubber bumper covering a socket for a 1/4" Allen wrench. (Fig. 16) Insert the wrench and rotate in or out as needed. (Fig. 17) One full turn is equal to approximately 1/16" (1.6) of adjustment. Re-attach the rubber bumper.

B

FIG. 15

FIG. 16

FIG. 17

BMPRBR Rubber Bumper

F