cross member: 48” o.c. lights 2: combo emerg/exit light w ... diligence/modular and...

78

Upload: lydien

Post on 01-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

August 1, 2016

August 1, 201602-46

Matthew Mackel

Director, Business Development

PO Box 701273

Houston, TX 77270

August 1, 2016

18x44 CLASSROOM SIDESTACKED (CL17A)

GENERAL BUILDING SPECIFICATIONS

Customer Acceptance

FRAME ELECTRIC Main Beams: 12” Jr. I-beam Load Center: 125A, 120V/240V, 1 phase, Exterior Type: Outrigger Lights 1: 2x4 Fixtures, T8 with elec ballasts Cross Member: 48” O.C. Lights 2: Combo emerg/exit light w/ remote head Hitch: Detachable Underslung Switches: 20A, Std white toggle type - Dual switching Axles: Triple with Brakes as Needed Receptacles: 20A, Std white, duplex type, GFI as needed

Raceway: EMT, Voice/Data roughin FLOOR (50lb live load) Bottom Board: 0.040 Mobilflex PLUMBING Joists: 2x8, #2 SYP at 16” O.C. Water Closet: None Insulation: R-22 Unfaced Lavatory: None Decking: Single ¾ Sturd-I-Floor Plywood Sink: None Floor Covering: 1/8 VCT Throughout Water Heater: None Trim: 4” Vinyl cove base Supply: None Misc: NA Waste: None

Misc: None EXT/INT WALLS (140 mph/ 3 sec) Studs: 2x6, #2 SYP @ 16” O.C. Plates: 2x6, #2 SYP : (2) Top (1) Bottom HVAC Sheathing: None Heat/Cool: 3 Ton / 10KW Wall Hung Wall Covering: 5/8 Vinyl Covered Gyp, Type-X Duct: Free blow into room at wall grille Insulation: R-15 Kraft (ext) Supply: None Partitions: None Return: Wall grille at unit Partitions: None Thermostat: Programmable, one per unit Siding/Trim: 3/8 LP Smartside Exhaust Fan: None

Misc: NA ROOF Mateline Truss: Transverse Multilayer Plywood Beam STATE LABELS and APPROVALS Rafters: 2x8, #2 SYP @ 24” O.C. IBC, IPC, NEC and ADA Sheathing: 7/16 Densdeck TX/LA/OK Approval Insulation: R-30 Kraft Insulation Additional State approval - see Pricing Catalog Ceiling: 2x4 Grid @ 8’6” Roofing: 45mil EPDM Misc: 48” Overhang Endwalls Only

INT/EXT DOORS Exterior Doors: 36”x 80” Commercial Steel with metal

frame and 10x10 vision panel Hardware deadbolts with Push/Pull

Interior Doors None

WINDOWS Size: 30x50 Vinyl Vert Slidr, Clear, DIG, 1” blinds Size: Qty 2

INTERIOR FURNISHING Base/Wall Cabinets: None Markerbd/Tackbd: None

24x64 CLASSROOM BUILDING (CL17B)

BUILDING SPECIFICATIONS

Customer Acceptance

1.0 FRAME 1.1 TYPE: Outrigger. 1.2 BEAM: M12x11.8# I-beam. 1.3 OUTRIGGER: 14 ga. formed steel @ 48" o.c. 1.4 CROSSMEMBER: 14 ga. formed steel @ 48" o.c. 1.5 HEADERS: 10 ga. formed member with tapered ends installed on front. 1.6 HITCH: Demountable with 2-5/16" coupler and elevating jack. 1.7 AXLES: Triple 5000# with electric brakes on 2 axles. Each frame shall be equipped with one set

of additional hangers to allow for future installation of one axle. 1.8 TIRES: 8:00 x 14.5 10 ply rated. 1.9 PAINT: Black asphalt on entire assembly less axles.

2.0 FLOOR 2.1 BOTTOM BOARD: .040 one piece rolled type asphalt. 2.2 INSULATION: R-21 Kraft faced fiberglass batts. 2.3 JOISTS: 2x6 #2 yellow pine installed transverse @ 16" o.c. 2.4 PERIMETER RAILS: Double 2x6 #2 yellow pine on all sides and ends of each module.

2.5 DECKING: Single layer 3/4" tongue and groove underlayment grade plywood installed perpendicular to floor joists. Hold back decking 2” each side of mateline and ship loose 4” wide pieces of ¾” plywood for site installation.

2.6 COVERING: 1/8” 12” x 12” vinyl composition tile shall be plant installed. Tile shall be held back at mateline and pieced in on site. MODULE MANUFACTURER shall shiploose tile to be installed at the mateline tile seam.

3.0 EXTERIOR WALLS 3.1 TYPE: IBC framing. 3.2 STUDS: 2x6 #2 SYP @ 16” o.c. 3.3 BOTTOM PLATE: Single 2x6 #3 SYP. 3.4 TOP PLATE: Double 2x6 #3 SYP. 3.5 HEADERS: Double 2x6 #2 SYP on edge with 1/2" CDX plywood filler. 3.6 SILLS: Flat 2x6 #2 SYP. 3.7 WALL HEIGHT: Minimum 8'- 1 -1/2", refer to prints.

3.8 INTERIOR FINISH: 1/2” Vinyl covered gypsum wall board installed full height all walls. VCG shall be installed flush to mateline. Ship loose 4” wide vinyl covered batten for installation on site. VCG shall be Ruff Stuff White.

3.9 INSULATION: R-19 Kraft faced fiberglass batts to roof.

3.10 SHEATHING: 15# felt entire exterior full height entire exterior

3.11 SIDING: LP SmartPanel Fiber Siding. Color and profile shall be from manufacturer's standard

3.12 TRIM: SmartPanel Trim. Color and profile shall be from manufacturer's standard

24x64 CLASSROOM BUILDING (CL17B)

BUILDING SPECIFICATIONS

Customer Acceptance

3.0 EXTERIOR WALLS (continued) 3.13 TIE DOWNS: Frame ties provided and installed on site – shop drawings to identify location/quantity.

3.14 SKIRTING: Same material as used for exterior siding installed to grade with vented panels and crawl space access panel.

3.15 NOTE: Not Applicable.

4.0 INTERIOR WALLS 4.1 STUDS: 2x4 stud grade SYP @ 16" o.c. 4.2 BOTTOM PLATE: Single 2x4 #3 SYP. 4.3 TOP PLATE: Double 2x4 #3 SYP. 4.4 HEADERS: Double 2x4 #2 SYP on edge with 1/2" CDX plywood filler. 4.5 WALL HEIGHT: Classroom dividing wall shall be constructed full height to roof structure.

4.6 INTERIOR FINISH: 1/2” Vinyl covered gypsum wall board installed full height all walls. VCG shall be installed flush to mateline. Ship loose 4” wide vinyl covered batten for installation on site. VCG shall be Ruff Stuff White.

4.7 INSULATION: R-11 unfaced fiberglass batts full height all interior walls.

5.0 MOULDING 5.1 BASE: 4” vinyl cove base throughout. Base shall be plant installed.

5.2 VERTICAL: Prefinished vinyl wrapped wood battens installed on all seams.

5.3 WINDOWS: The jambs of all windows shall be finished with vinyl faced luan to match wall vinyl.

6.0 ROOF 6.1 RAFTERS: 2x6 #2 yellow pine installed @ 24" o.c. Rafters to be installed so as to provide a minimum

2:12 pitch. 6.2 RIDGE GIRDER: Single 3-1/2" x 24” pre-engineered wood girder each side of mate line. 6.3 BRIDGING: 1-1/2" steel angle installed @ 8' o.c. from girder to rafter.

6.4 CEILING: 2x4 acoustical mineral fiber in suspended T-grid system. Ceiling tiles shall be Armstrong 1729 or equal. Ceiling shall be installed at the factory.

The ceiling tile and grid shall be installed independent in each modular section with a white melamine cap site installed at the mateline seam. Melamine cap shall be shipped loose.

6.5 CEILING HEIGHT: The finished ceiling height throughout the building is 7'-10 1/2".

6.6 INSULATION: R-38 Un-faced fiberglass batts installed between the rafters. Insulation shall be held in place by the use of nylon/plastic netting.

6.7 SHEATHING: ½” CDX or 7/16" oriented strand board installed perpendicular to the roof joists.

24x64 CLASSROOM BUILDING (CL17B)

BUILDING SPECIFICATIONS

Customer Acceptance

6.0 ROOF (continued) 6.8 ROOFING: 29 ga. galvalume "R" panel steel installed over one layer of 15# felt.

6.9 DRAFT STOP: N/A

7.0 EXTERIOR DOORS 7.1 DOORS: 1-3/4" x 36" x 80" 18 ga. hollow core commercial steel. 7.2 FRAMES: All exterior doors will be equipped with 16 ga. commercial steel frames.

7.3 LOCKSET/ HARDWARE: All exterior doors will be equipped with deadbolt assembly with two keys per door.

7.4 CLOSER: A heavy duty hydraulic closer shall be provided on all exterior doors. Door closers shall be “Door-o-Matic” SC61, or equal.

7.5 EXTERIOR PULL/ INTERIOR PUSH: Each exterior door shall be equipped with a Rockwood 70CXUS28. Or equal push/pull

plate.

7.6 FINISH: The interior and exterior side of the doors and frames will be painted to match the building exterior body color.

8.0 INTERIOR DOORS (Option with Restroom Units only) 8.1 DOORS: 1-3/4" X 36” X 80" high prefinished woodgrain stain grade hollow core wood doors, brown

finish. All doors shall be by TELL Manufacturing, or equal.

8.2 FRAMES: All interior doors shall be set in prefinished steel frames with baked enamel finish. All frames shall be by TELL Manufacturing, or equal.

8.3 HARDWARE: All interior doors shall be equipped with mortise hinges.

8.4 CLOSERS: None. 8.5 LATCHSETS: Restroom doors shall be equipped with privacy function lever handle lock set.

9.0 WINDOWS 9.1 TYPE: All windows shall be 58”x24” horizontal slider with clear single strength glazing bronze

painted finish frames and insect screen. Windows shall be H & R Series 600, or equal.

9.2 MINI-BLINDS: All windows shall be equipped with 1” aluminum slat mini-blinds. Color shall be #026 Gray.

10.0 ELECTRICAL 10.1 SERVICE: 120/240v, single phase, 3W, 60hz. 10.2 "MDP": 1 phase, interior, flush mount with 200 AMP main breaker. Panel shall be by Square

“D”, or equal.

24x64 CLASSROOM BUILDING (CL17B)

BUILDING SPECIFICATIONS

Customer Acceptance

10.0 ELECTRICAL (continued) 10.3 ENTRANCE: Electrical service entry location shall be stubbed through the floor at the plant for

connection to existing service by others on site.

10.4 RACEWAY: Minimum #12 AWG copper wire in concealed EMT conduit with set screw fittings. Wire insulation to be THHN.

10.5 LIGHTS: 2’x4’, 120v, four tube, recessed, fluorescent light with acrylic diffuser. Lights shall be equipped with T-8 lamps and electronic ballasts. Lights shall be plant wired and secured to the roof joists for shipment to the job site. Lights shall be Metalux 2GR8432UNLVEB8IU, or equal.

10.6 EXTERIOR LIGHT: 70 Watt high pressure sodium exterior wall pack with photo cell; Lumark HPWM70P. Refer to drawings for location.

10.7 RECEPTACLES: 120v Ivory duplex grounding type with matching plastic cover. Receptacles shall be Leviton BR20-SI, or equal. (1) 110 volt, wired dedicated circuit installed above the ceiling in each classroom Refer to the drawings for location.

(1) 110 volt dedicated outlet for fire alarm control panel.

10.8 SWITCHES: 120v 20 AMP toggle type commercial specification grade. Device and cover shall be Ivory in color. (2) Switches shall be provided in each classroom and wired in a manner allowing half the fixtures to be illuminated at one time.

Switches shall be Leviton CS120-CI, or equal.

10.9 EXIT LIGHTS: 110v illuminated exit signs with battery backup. (Plant installed) Exit lights shall be LPX70RWH – Surelite, or equal.

10.10 LOW VOLTAGE: J-boxes with conduit to above ceiling with pull wire shall be provided for fire alarm devices and computer/telephone. Refer to drawings for location and quantities. All wiring and devices provided and installed by others.

11.0 PLUMBING None

12.0 H.V.A.C. 12.1 COOLING: (2) 36,000 B.T.U. 240v 1 phase wall hung H.V.A.C. system with fresh air intake damper.

HVAC units shall be Bard WA36A10, or equal.

12.2 HEATING: 10kw 240v electric resistance heat strip in each air conditioner.

12.3 SUPPLY: Through rigid foil faced fiberglass duct with wall thickness equal to R6 installed below rafters with insulated circular flex duct to designated diffusers.

12.4 DIFFUSERS: 24” x 24” White stamped metal with adjustable damper. Diffusers shall be Airmate 705- 8, or equal.

24x64 CLASSROOM BUILDING (CL17B)

BUILDING SPECIFICATIONS

Customer Acceptance

12.0 H.V.A.C. (continued) 12.5 RETURN AIR: Through a wall mounted grill located at the HVAC unit (no return plenum).

12.6 THERMOSTAT: (1) Programmable thermostat shall be provided for each HVAC unit, Luxpro PSP511 or equal.

13.0 FURNISHINGS 13.1 TACKBOARDS: Each classroom shall be equipped with (1) 4’-0” x 4’-0” Claridge #844F or equal,

tackboard with heavy duty satin finish aluminum frames. (To be plant installed.)

13.2 MARKERBOARDS: Each classroom will be equipped with (2) 4'-0" x 8'-0" Claridge #MLC 2048 or equal, 2048 white marker boards with heavy duty satin finished anodized aluminum frames and troughs. (To be plant installed)

13.3 FIRE EXTINGUISHERS: 5# ABC Surface mount fire extinguishers installed adjacent to each exterior door.

14.0 DESIGN CRITERIA 14.1 FLOORS: The floor systems shall be constructed to accommodate a live load of 50lb/sft in addition

to the dead loads.

14.2 WALLS: The exterior walls shall be framed, braced and secured in accordance with the requirements of the IBC; 170 mph wind speed design load.

14.3 ROOFS: All structural components of the roof system shall be designed and erected to span their respective areas and carry a live load of 20lb/sft and a dead load of 10lb/sft.

14.4 HEATING: The heating system shall be designed to maintain an interior temperature of 75 degrees + or – 2 degrees.

14.5 COOLING: The cooling system shall be designed to maintain an interior temperature of 75 degree + or – 2 degrees.

14.6 CODES: The building shall be built in accordance with the following codes. A. International Building Code, 2012 B. 2007 ASHRAE 90.1 C. International Mechanical Code, 2012 D. National Electrical Code, 2012 E. International Energy Conservation Code, 2009 F. Texas Accessibility Standards G. State of Texas Industrialized, Housing and Building Rules, as administered by the

Texas Department of Licensing and Regulations. H. In addition to TX approvals, the building shall be approved for LA,AR and OK.

14.7 SPECIAL: The specifications and codes as illustrated herein will be modified as necessary to accommodate additional State approvals as needed for the facility types listed within our proposal response. Refer to the Pricing Catalog information for the applicability of additional States.

24x64 CLASSROOM BUILDING (CL17B)

BUILDING SPECIFICATIONS

Customer Acceptance

14.0 DESIGN CRITERIA (continued)

The scope of this design does not include accessibility elements required for the project site. It is the owners responsibility to have these designs developed and to make submittal as required to the authorities having jurisdiction through their design professional.

END OF BUILDING SPECIFICATIONS – 24x64 Classroom

BASE MODEL CLASSROOM BUILDING WING (CL03 – CL12)

BUILDING SPECIFICATIONS

Customer Acceptance

1.0 FRAME 1.1 TYPE: Outrigger - 12”. 1.2 BEAM: M12x11.8# I-beam. 1.3 OUTRIGGER: 14 ga. formed steel @ 48" o.c. 1.4 CROSSMEMBER: 14 ga. formed steel @ 48" o.c. 1.5 HEADERS: 10 ga. formed member with tapered ends installed on front. 1.6 HITCH: Demountable with 2-5/16" coupler and elevating jack. 1.7 TIRES: 8:00 x 14.5 10 ply rated. 1.8 PAINT: Black asphalt on entire assembly less axles. 1.9 AXLES: As required for transport.

2.0 FLOOR 2.1 BOTTOM BOARD: .040 one piece rolled continuous construction board. 2.2 INSULATION: R-21 Kraft faced fiberglass batts. 2.3 JOISTS: 2x6 #2 SYP installed transverse at 16" o.c. 2.4 PERIMETER RAILS: Double 2x6 #2 SYP on all sides. 2.5 DECKING: Single layer ¾ SturdiFloor T&G plywood installed perpendicular to floor joists. 2.6 COVERING: 1/8” Vinyl composition floor tile throughout

3.0 EXTERIOR WALLS 3.1 TYPE: IBC Framing 3.2 STUDS: 2x6 #2 SYP @ 16" O.C. 3.3 BOTTOM PLATE: Single 2x6 #3 SYP. 3.4 TOP PLATE: Double 2x6 #3 SYP. 3.5 HEADERS: Double 2x6 #2 SYP on edge with 1/2" CDX plywood filler. 3.6 SILLS: Flat 2x6 #2 SYP. 3.7 WALL HEIGHT: As required per plan. 3.8 FIRE BLOCKS: 2x4 installed @ ceiling line. 3.9 INTERIOR FINISH: ½” Vinyl covered gypsum installed full height throughout. VCG shall be Ruff Stuff

White. Corridor walls to be one hour fire rated where required by code.

3.10 INSULATION: R-19 Kraft faced fiberglass batts installed to roof structure.

3.11 SHEATHING: 15# felt entire exterior full height entire exterior .

3.12 SIDING: LP SmartPanel Fiber siding. Color and profile shall be from manufacturer's standard.

3.13 TRIM: SmartPanel Trim. Color and profile shall be from manufacturer's standard.

3.14 FASCIA/RAKE: None. 3.15 TIE DOWNS: Frame ties per plans.

3.16 SKIRTING: LP SmartPanel Fiber siding. Color and profile shall be from manufacturer's standard.

BASE MODEL CLASSROOM BUILDING WING (CL03 – CL12)

BUILDING SPECIFICATIONS

Customer Acceptance

4.0 INTERIOR WALLS 4.1 STUDS: 2x4 #2 SYP @ 16" o.c. 4.2 BOTTOM PLATE: Single 2x4 #3 SYP. 4.3 TOP PLATE: Double 2x4 #3 SYP. 4.4 HEADERS: Double 2x4 #2 SYP on edge with 1/2" CDX plywood filler.

4.5 WALL HEIGHT: As required per plan.

4.6 INTERIOR FINISH: 1/2” vinyl covered gypsum installed full height throughout. VCG shall be Ruff Stuff White. Corridor walls to be one hour fire rated as required by code.

4.7 INSULATION: R-13 Unfaced insulation within the partition walls between classrooms.

5.0 MOULDING 5.1 BASE: 4" Vinyl cove base throughout entire building - 6” Vinyl within restrooms (as applicable) 5.2 WINDOWS: The jambs of all windows shall be finished the same as the walls. 5.3 WALL TRIM: Wall seams and corners shall receive prefinished wood trims as applicable.

6.0 ROOF 6.1 RAFTERS: 2x6 #2 SYP installed @ 24" O.C. Rafters shall be installed so as to provide a minimum

pitch.

6.2 RAILS: 2x6 #2 SYP. 6.3 RIDGE GIRDER: Double 1-1/2" pre-engineered wood girder or multi-layer plywood beam each side of mate

line shall be utilized to support spans as shown. Columns concealed within walls.

6.4 BRIDGING: 1-1/2" steel angle installed @ 8' o.c. from girder to rafter. 6.5 CEILING: Standard 2x4 acoustical, Armstrong, installed in the field by WS. Corridor shall have

one hour rated subceiling.

6.6 CEILING HEIGHT: The finished ceiling height throughout the building shall be 7'-10". 6.7 INSULATION: R-38 Un-faced fiberglass batts installed between roof joists. Nylon netting shall be used

to hold insulation in place.

6.8 DRAFT STOP: As illustrated on final engineered manufacturer's shop drawings. 6.9 SHEATHING: 3/8” FR OSB installed perpendicular to the roof joists and as required for wind loading. 6.10 ROOFING: 0.045 EPDM rubber membrane installed as required for wind loading .

7.0 EXTERIOR DOORS 7.1 DOORS: (2) 72" X 80" 16 Ga. hollow core commercial steel - by TELL Manufacturing, or equal. 7.2 FRAMES: Steel doors shall be equipped with 18 Ga. knockdown commercial steel frames - by TELL

Manufacturing, or equal.

7.3 HARDWARE: All exterior steel doors shall be equipped with 1-1/2 pr. of 4-1/2"x4-1/2" ball bearing, non- removable pin butt hinges, full weatherstrip and threshold. Each set of exit doors shall have

panic hardware by TELL Manufacturing, or equal.

BASE MODEL CLASSROOM BUILDING WING (CL03 – CL12)

BUILDING SPECIFICATIONS

Customer Acceptance

7.0 EXTERIOR DOORS (continued) 7.4 WINDOW: 8x30 Vision panel within each door.

7.5 EXIT DEVICE: Exterior steel doors shall be equipped with panic bar hardware per manufacturer’s std - by TELL Manufacturing, or equal.

7.6 CLOSER: A hydraulic closer with back check feature shall be provided on all exterior steel doors - by TELL Manufacturing, or equal.

7.7 FINISH: The interior and exterior side of the steel doors and frames shall be painted to match the exterior trim.

8.0 INTERIOR DOORS 8.1 DOORS: 1-3/4" X 36” X 80" high prefinished woodgrain stain grade hollow core wood doors, brown

finish. All doors shall be by TELL Manufacturing, or equal. Corridor doors shall be 20 minute labeled for fire rating as required with closers or self closing hinges.

8.2 FRAMES: All interior doors shall be set in prefinished steel frames with baked enamel finish. All frames shall be by TELL Manufacturing, or equal.

8.3 HARDWARE: All interior doors shall be equipped with mortise hinges.

8.4 CLOSERS: None. 8.5 LATCHSETS: Restroom doors shall be equipped with privacy function lever handle lock set. All

remaining interior doors to have passage lever handle lock set.

8.6 MISC: All interior doors shall have 8x30 vision panel (excluding restrooms).

9.0 WINDOWS 9.1 TYPE: 36" X 60" Aluminum vertical slider with single clear glazing, bronze painted frames, and

insect screens. (Qty of 1 per classroom – no blinds)

10.0 ELECTRICAL 10.1 SERVICE: 120/208/240v- 1 phase- 3W- 60hz.

10.2 "MDP": Main distribution panel (MDP) shall be exterior mounted and installed by others in the field. Homerun wiring for the sub-panels back to the “MDP” shall be performed in the field by others.

10.3 SUB-PANELS: 24 Circuit 1 phase, indoor, surface mount with main lug only – 150 amp rated. (1) Sub- panel shall be provided as required and refer to final engineered manufacturer's shop

drawings.

10.4 BREAKERS: All breakers shall be plug in type.

10.5 ENTRANCE: EMT conduit stubbed through floor. 10.6 CROSSOVERS: J-boxes shall be installed above the ceiling for electrical crossovers.

BASE MODEL CLASSROOM BUILDING WING (CL03 – CL12)

BUILDING SPECIFICATIONS

Customer Acceptance

10.0 ELECTRICAL (continued) 10.7 RACEWAY/

CONDUCTORS: Minimum #12 AWG type THHN copper wire in concealed EMT or ENT conduit with appropriate fittings.

10.8 FLUORESCENT LIGHTS: 4'-0" four tube, recessed, fluorescent light with acrylic prismatic diffusers and T8 Bulbs

with electronic ballasts. Fixtures are to be factory installed.

10.9 INCANDESCENT LIGHTS: None.

10.10 EMERGENCY LIGHTS: Dual head emergency light with back up battery power shall be plant installed.

10.11 EXIT LIGHTS: Dual faced 120 volt ceiling mount exit light with back up battery power shall be plant installed. One installed over each exterior door.

10.12 RECEPTACLES: 120v 20 AMP duplex specification grade grounding type with matching plastic cover. Ivory. Designated receptacles shall be provided with GFCI protection.

10.13 SWITCHES: 120v 20 AMP toggle type with matching plastic cover. Ivory.

10.14 MISC.: Provide (2) empty j-boxes with ¾ conduit stubbed above the grid per classroom by the plant for voice/data system wiring and devices by others. Fire alarm as required with rough-

in by the plant for system wiring and devices by others.

10.15 MISC.: Each classroom shall have (1) 120V receptacle and associated data box mounted above the grid for overhead projector equipment to be provided by the Owner.

11.0 PLUMBING (if option is selected) 11.1 WATERLINES: Type "L" copper with sweat copper fittings. Fixtures shall be provided with shut-off valves. 11.2 WASTELINES: PVC-DWV-SCH-40 drain, waste and vent lines.

11.3 WATERHEATER: 20 Gallon, 240v Electric with T&P valve. A shut-off shall be provided to allow client to provide cold water only to the lavatories.

11.4 WATER CLOSET: White vitreous china tank type with open front seat and elongated bowl. Designated water closets shall be installed for the handicapped.

11.5 MODESTY PART.: 5’-0” high steel with baked on enamel finish modesty partition and urinal blinds. Units shall be installed 12” from floor with modesty door and lock. Color shall be: Almond.

11.6 URINAL: White vitreous china wall hung with flushometer valve.

11.7 LAVATORIES: Vitreous china wall hung with 4" washerless centerset faucet. Designated lavatories shall be installed for the handicapped and shall be equipped with Handi-guard water supply and drain protective covers and wrist blade handle.

BASE MODEL CLASSROOM BUILDING WING (CL03 – CL12)

BUILDING SPECIFICATIONS

Customer Acceptance

11.0 PLUMBING (continued) 11.8 MOP SINK: Single bowl fiberglass mounted on legs with laundry tray faucet. 11.9 SINK: Not Applicable

11.10 WATER COOLER: 8 GPH wall mounted refrigerated water coolers. (1) Water cooler shall be installed for the handicapped.

11.11 ACCESSORIES: Single roll toilet paper holder at each water closet. Stainless steel grab bars at each handicapped water closet. 18"x36" metal edged mirror above each lavatory in restrooms only.

12.0 H.V.A.C. 12.1 PACKAGED: 36,000 B.T.U., 240V, 1 phase, wall mount air conditioner at classrooms and

other areas as applicable and as shown on the manufacturer’s shop drawings.

12.2 HEATING: 240v Electric resistance heat strip in each air conditioner.

12.3 SUPPLY DUCTS: Rigid, foil faced fiberglass insulated duct board w/ insulated flex (R6 min) to diffusers.

12.4 DIFFUSERS: Standard size, 24x24, ceiling mount throughout building.

12.5 RETURN AIR: Rigid, foil faced fiberglass insulated duct board w/ insulated flex (R5 min) from diffusers back to plenum walls.

12.6 THERMOSTAT: Programmable thermostat with each HVAC unit. 12.7 EXHAUST FANS: None.

13.0 CASEWORK None .

14.0 FURNISHINGS 14.1 TACKBOARDS: Each classroom shall be equipped with (1) 4'-0"x4'-0” tack board with heavy duty satin

finish aluminum frames; plant installed.

14.2 MARKERBOARDS: Each classroom shall be equipped with (1) 4’x16’ white marker boards with aluminum trim and marker trough; plant installed.

15.0 DESIGN CRITERIA 15.1 FLOORS: The floor systems shall be constructed to accommodate a live load of 50lb/sft (100lb/sft

corridor) in addition to the dead loads.

15.2 WALLS: The exterior walls shall be framed, braced and secured in accordance with the requirements of the IBC for 140 mph wind speed design load.

15.3 ROOFS: All structural components of the roof system shall be designed and erected to span their respective areas and carry a live load of 20lb/sft and a dead load of10lb/sft.

BASE MODEL CLASSROOM BUILDING WING (CL03 – CL12)

BUILDING SPECIFICATIONS

Customer Acceptance

15.0 DESIGN CRITERIA (continued) 15.4 HEAT/COOL: The heating/cooling system shall be designed as per industry standards and will be

designated on the manufacturer’s shop drawings.

15.5 CODES: The building shall be built in accordance with the following codes. A. International Building Code, 2012 B. 2007 ASHRAE 90.1 C. International Mechanical Code, 2012 D. National Electrical Code, 2012 E. International Energy Conservation Code, 2009 F. Texas Accessibility Standards G. State of Texas Industrialized, Housing and Building Rules, as administered by the

Texas Department of Licensing and Regulations. H. In addition to TX approvals, the building shall be approved for LA,AR and OK.

15.6 SPECIAL: The specifications and codes as illustrated herein will be modified as necessary to accommodate additional State approvals as needed for the facility types listed within our proposal response. Refer to the Pricing Catalog information for the applicability of additional States.

The scope of this design does not include accessibility elements required for the project site. It is the owners responsibility to have these designs developed and to make submittal as required to the authorities having jurisdiction through their design professional.

END OF BUILDING SPECIFICATIONS - Classroom Wing

BASE MODEL CLASSROOM BUILDING DOUBLES (CL01 – CL02)

BUILDING SPECIFICATIONS

Customer Acceptance

1.0 FRAME 1.1 TYPE: Outrigger. 1.2 BEAM: M12x11.8# I-beam. 1.3 OUTRIGGER: 14 ga. formed steel @ 48" o.c. 1.4 CROSSMEMBER: 14 ga. formed steel @ 48" o.c. 1.5 HEADERS: 10 ga. formed member with tapered ends installed on front. 1.6 HITCH: Demountable with 2-5/16" coupler and elevating jack. 1.7 AXLES: Triple 5000# with electric brakes on 2 axles. Each frame shall be equipped with one set

of additional hangers to allow for future installation of one axle. 1.8 TIRES: 8:00 x 14.5 10 ply rated. 1.9 PAINT: Black asphalt on entire assembly less axles.

2.0 FLOOR 2.1 BOTTOM BOARD: .040 one piece rolled type asphalt. 2.2 INSULATION: R-21 Kraft faced fiberglass batts. 2.3 JOISTS: 2x6 #2 yellow pine installed transverse @ 16" o.c. 2.4 PERIMETER RAILS: Double 2x6 #2 yellow pine on all sides and ends of each module.

2.5 DECKING: Single layer 3/4" tongue and groove underlayment grade plywood installed perpendicular to floor joists. Hold back decking 2” each side of mateline and ship loose 4” wide pieces of ¾” plywood for site installation.

2.6 COVERING: 1/8” 12” x 12” vinyl composition tile shall be plant installed. Tile shall be held back at mateline and pieced in on site. MODULE MANUFACTURER shall shiploose tile to be installed at the mateline tile seam.

3.0 EXTERIOR WALLS 3.1 TYPE: IBC framing. 3.2 STUDS: 2x6 #2 SYP @ 16” o.c. 3.3 BOTTOM PLATE: Single 2x6 #3 SYP. 3.4 TOP PLATE: Double 2x6 #3 SYP. 3.5 HEADERS: Double 2x6 #2 SYP on edge with 1/2" CDX plywood filler. 3.6 SILLS: Flat 2x6 #2 SYP. 3.7 WALL HEIGHT: Minimum 8'- 1 -1/2", refer to prints.

3.8 INTERIOR FINISH: 1/2” Vinyl covered gypsum wall board installed full height all walls. VCG shall be installed flush to mateline. Ship loose 4” wide vinyl covered batten for installation on site. VCG shall be Ruff Stuff White.

3.9 INSULATION: R-19 Kraft faced fiberglass batts to roof.

3.10 SHEATHING: 15# felt entire exterior full height entire exterior

3.11 SIDING: LP SmartPanel Fiber Siding. Color and profile shall be from manufacturer's standard

3.12 TRIM: SmartPanel Trim. Color and profile shall be from manufacturer's standard

BASE MODEL CLASSROOM BUILDING DOUBLES (CL01 – CL02)

BUILDING SPECIFICATIONS

Customer Acceptance

3.0 EXTERIOR WALLS (continued) 3.13 TIE DOWNS: Frame ties provided and installed on site – shop drawings to identify location/quantity.

3.14 SKIRTING: Same material as used for exterior siding installed to grade with vented panels and crawl space access panel.

3.15 NOTE: Not Applicable.

4.0 INTERIOR WALLS 4.1 STUDS: 2x4 stud grade SYP @ 16" o.c. 4.2 BOTTOM PLATE: Single 2x4 #3 SYP. 4.3 TOP PLATE: Double 2x4 #3 SYP. 4.4 HEADERS: Double 2x4 #2 SYP on edge with 1/2" CDX plywood filler. 4.5 WALL HEIGHT: Classroom dividing wall shall be constructed full height to roof structure.

4.6 INTERIOR FINISH: 1/2” Vinyl covered gypsum wall board installed full height all walls. VCG shall be installed flush to mateline. Ship loose 4” wide vinyl covered batten for installation on site. VCG shall be Ruff Stuff White.

4.7 INSULATION: R-11 unfaced fiberglass batts full height all interior walls.

5.0 MOULDING 5.1 BASE: 4” vinyl cove base throughout. Base shall be plant installed.

5.2 VERTICAL: Prefinished vinyl wrapped wood battens installed on all seams.

5.3 WINDOWS: The jambs of all windows shall be finished with vinyl faced luan to match wall vinyl.

6.0 ROOF 6.1 RAFTERS: 2x6 #2 yellow pine installed @ 24" o.c. Rafters to be installed so as to provide a minimum

2:12 pitch. 6.2 RIDGE GIRDER: Single 3-1/2" x 24” pre-engineered wood girder each side of mate line. 6.3 BRIDGING: 1-1/2" steel angle installed @ 8' o.c. from girder to rafter.

6.4 CEILING: 2x4 acoustical mineral fiber in suspended T-grid system. Ceiling tiles shall be Armstrong 1729 or equal. Ceiling shall be installed at the factory.

The ceiling tile and grid shall be installed independent in each modular section with a white melamine cap site installed at the mateline seam. Melamine cap shall be shipped loose.

6.5 CEILING HEIGHT: The finished ceiling height throughout the building is 7'-10 1/2".

6.6 INSULATION: R-38 Un-faced fiberglass batts installed between the rafters. Insulation shall be held in place by the use of nylon/plastic netting.

6.7 SHEATHING: ½” CDX or 7/16" oriented strand board installed perpendicular to the roof joists.

BASE MODEL CLASSROOM BUILDING DOUBLES (CL01 – CL02)

BUILDING SPECIFICATIONS

Customer Acceptance

6.0 ROOF (continued) 6.8 ROOFING: 29 ga. galvalume "R" panel steel installed over one layer of 15# felt.

6.9 DRAFT STOP: N/A

7.0 EXTERIOR DOORS 7.1 DOORS: 1-3/4" x 36" x 80" 18 ga. hollow core commercial steel. 7.2 FRAMES: All exterior doors will be equipped with 16 ga. commercial steel frames.

7.3 LOCKSET/ HARDWARE: All exterior doors will be equipped with deadbolt assembly with two keys per door.

7.4 CLOSER: A heavy duty hydraulic closer shall be provided on all exterior doors. Door closers shall be “Door-o-Matic” SC61, or equal.

7.5 EXTERIOR PULL/ INTERIOR PUSH: Each exterior door shall be equipped with a Rockwood 70CXUS28. Or equal push/pull

plate.

7.6 FINISH: The interior and exterior side of the doors and frames will be painted to match the building exterior body color.

8.0 INTERIOR DOORS (Option with Restroom Units only) 8.1 DOORS: 1-3/4" X 36” X 80" high prefinished woodgrain stain grade hollow core wood doors, brown

finish. All doors shall be by TELL Manufacturing, or equal.

8.2 FRAMES: All interior doors shall be set in prefinished steel frames with baked enamel finish. All frames shall be by TELL Manufacturing, or equal.

8.3 HARDWARE: All interior doors shall be equipped with mortise hinges.

8.4 CLOSERS: None. 8.5 LATCHSETS: Restroom doors shall be equipped with privacy function lever handle lock set.

9.0 WINDOWS 9.1 TYPE: All windows shall be 58”x24” horizontal slider with clear single strength glazing bronze

painted finish frames and insect screen. Windows shall be H & R Series 600, or equal.

9.2 MINI-BLINDS: All windows shall be equipped with 1” aluminum slat mini-blinds. Color shall be #026 Gray.

10.0 ELECTRICAL 10.1 SERVICE: 120/240v, single phase, 3W, 60hz. 10.2 "MDP": 1 phase, interior, flush mount with 200 AMP main breaker. Panel shall be by Square

“D”, or equal.

BASE MODEL CLASSROOM BUILDING DOUBLES (CL01 – CL02)

BUILDING SPECIFICATIONS

Customer Acceptance

10.0 ELECTRICAL (continued) 10.3 ENTRANCE: Electrical service entry location shall be stubbed through the floor at the plant for

connection to existing service by others on site.

10.4 RACEWAY: Minimum #12 AWG copper wire in concealed EMT conduit with set screw fittings. Wire insulation to be THHN.

10.5 LIGHTS: 2’x4’, 120v, four tube, recessed, fluorescent light with acrylic diffuser. Lights shall be equipped with T-8 lamps and electronic ballasts. Lights shall be plant wired and secured to the roof joists for shipment to the job site. Lights shall be Metalux 2GR8432UNLVEB8IU, or equal.

10.6 EXTERIOR LIGHT: 70 Watt high pressure sodium exterior wall pack with photo cell; Lumark HPWM70P. Refer to drawings for location.

10.7 RECEPTACLES: 120v Ivory duplex grounding type with matching plastic cover. Receptacles shall be Leviton BR20-SI, or equal. (1) 110 volt, wired dedicated circuit installed above the ceiling in each classroom Refer to the drawings for location.

(1) 110 volt dedicated outlet for fire alarm control panel.

10.8 SWITCHES: 120v 20 AMP toggle type commercial specification grade. Device and cover shall be Ivory in color. (2) Switches shall be provided in each classroom and wired in a manner allowing half the fixtures to be illuminated at one time.

Switches shall be Leviton CS120-CI, or equal.

10.9 EXIT LIGHTS: 110v illuminated exit signs with battery backup. (Plant installed) Exit lights shall be LPX70RWH – Surelite, or equal.

10.10 LOW VOLTAGE: J-boxes with conduit to above ceiling with pull wire shall be provided for fire alarm devices and computer/telephone. Refer to drawings for location and quantities. All wiring and devices provided and installed by others.

11.0 PLUMBING (Option with Restroom Units only) 11.1 WATERLINES: Type "L" copper with sweat copper fittings. Fixtures shall be provided with shut-off valves.

11.2 WASTELINES: PVC-DWV-SCH-40 drain, waste and vent lines.

11.3 WATER HEATER: Insta-Hot, point of use, 240v Electric.

11.4 WATER CLOSET: White vitreous china tank type with open front seat and elongated bowl. Designated water closets shall be installed for the handicapped.

11.5 MODESTY PART.: Not Applicable.

11.6 URINAL: Not Applicable.

BASE MODEL CLASSROOM BUILDING DOUBLES (CL01 – CL02)

BUILDING SPECIFICATIONS

Customer Acceptance

11.0 PLUMBING (continued) 11.7 LAVATORIES: Vitreous china wall hung with 4" washerless centerset faucet. Lavatories shall be installed

for the handicapped and shall be equipped with Handi-guard water supply and drain protective covers and wrist blade handle.

11.8 MOP SINK: Not Applicable.

11.9 SINK: Not Applicable.

11.10 WATER COOLER: Not Applicable.

11.11 ACCESSORIES: Single roll toilet paper holder at each water closet.Stainless steel grab bars at each handicapped water closet.18"x36" metal edged mirror above each lavatory in restrooms only.

12.0 H.V.A.C. 12.1 COOLING: (2) 36,000 B.T.U. 240v 1 phase wall hung H.V.A.C. system with fresh air intake damper.

HVAC units shall be Bard WA36A10, or equal.

12.2 HEATING: 10kw 240v electric resistance heat strip in each air conditioner.

12.3 SUPPLY: Through rigid foil faced fiberglass duct with wall thickness equal to R6 installed below rafters with insulated circular flex duct to designated diffusers.

12.4 DIFFUSERS: 24” x 24” White stamped metal with adjustable damper. Diffusers shall be Airmate 705- 8, or equal.

12.5 RETURN AIR: Through a wall mounted grill located at the HVAC unit (no return plenum).

12.6 THERMOSTAT: (1) Programmable thermostat shall be provided for each HVAC unit, Luxpro PSP511 or equal.

13.0 FURNISHINGS 13.1 TACKBOARDS: Each classroom shall be equipped with (1) 4’-0” x 4’-0” Claridge #844F or equal,

tackboard with heavy duty satin finish aluminum frames. (To be plant installed.)

13.2 MARKERBOARDS: Each classroom will be equipped with (2) 4'-0" x 8'-0" Claridge #MLC 2048 or equal, 2048 white marker boards with heavy duty satin finished anodized aluminum frames and troughs. (To be plant installed)

13.3 FIRE EXTINGUISHERS: 5# ABC Surface mount fire extinguishers installed adjacent to each exterior door.

BASE MODEL CLASSROOM BUILDING DOUBLES (CL01 – CL02)

BUILDING SPECIFICATIONS

Customer Acceptance

14.0 DESIGN CRITERIA 14.1 FLOORS: The floor systems shall be constructed to accommodate a live load of 50lb/sft in addition

to the dead loads.

14.2 WALLS: The exterior walls shall be framed, braced and secured in accordance with the requirements of the IBC; 170 mph wind speed design load.

14.3 ROOFS: All structural components of the roof system shall be designed and erected to span their respective areas and carry a live load of 20lb/sft and a dead load of 10lb/sft.

14.4 HEATING: The heating system shall be designed to maintain an interior temperature of 75 degrees + or – 2 degrees.

14.5 COOLING: The cooling system shall be designed to maintain an interior temperature of 75 degree + or – 2 degrees.

14.6 CODES: The building shall be built in accordance with the following codes. A. International Building Code, 2012 B. 2007 ASHRAE 90.1 C. International Mechanical Code, 2012 D. National Electrical Code, 2012 E. International Energy Conservation Code, 2009 F. Texas Accessibility Standards G. State of Texas Industrialized, Housing and Building Rules, as administered by the

Texas Department of Licensing and Regulations. H. In addition to TX approvals, the building shall be approved for LA,AR and OK.

14.7 SPECIAL: The specifications and codes as illustrated herein will be modified as necessary to accommodate additional State approvals as needed for the facility types listed within our proposal response. Refer to the Pricing Catalog information for the applicability of additional States.

The scope of this design does not include accessibility elements required for the project site. It is the owners responsibility to have these designs developed and to make submittal as required to the authorities having jurisdiction through their design professional.

END OF BUILDING SPECIFICATIONS - Double

CLASSROOMS FLEXX BOXX (CL17C-CL17L)

GENERAL BUILDING SPECIFICATIONS

Customer Acceptance

FRAME ELECTRIC Main Beams: 12” Jr. I-beam Load Center: None - Option per Client Selection Type: Outrigger Lights 1: None - Option per Client Selection Cross Member: 48” O.C. Lights 2: None - Option per Client Selection Hitch: Detachable Underslung Switches: None - Option per Client Selection Axles: Triple with Brakes as Needed Receptacles: None - Option per Client Selection

Raceway: None - Option per Client Selection FLOOR (50lb live load) Bottom Board: 0.040 Mobilflex PLUMBING Joists: 2x6 or 2x8, #2 SYP at 16” O.C. Water Closet: None - Option per Client Selection Insulation: R-22 Unfaced Lavatory: None - Option per Client Selection Decking: Single ¾ Sturd-I-Floor Plywood Sink: None - Option per Client Selection Floor Covering: None - Option per Client Selection Water Heater: None - Option per Client Selection Trim: None - Option per Client Selection Supply: None - Option per Client Selection Misc: NA Waste: None - Option per Client Selection

Misc: None - Option per Client Selection EXT/INT WALLS (140 mph/ 3 sec) Studs: 2x6, #2 SYP @ 16” O.C. Plates: 2x6, #2 SYP : (2) Top (1) Bottom HVAC Sheathing: None Heat/Cool: None - Option per Client Selection Wall Covering: 1/2 Vinyl Covered Gyp - Int Height8’ Duct: None - Option per Client Selection Insulation: R-13 Kraft (ext) Supply: None - Option per Client Selection Partitions: None - Option per Client Selection Return: None - Option per Client Selection Partitions: None - Option per Client Selection Thermostat: None - Option per Client Selection Siding/Trim: 3/8 LP Smartside Exhaust Fan: None - Option per Client Selection

Misc: None - Option per Client Selection ROOF Mateline Truss: Transverse Multilayer Plywood Beam STATE LABELS and APPROVALS Rafters: 2x8, #2 SYP @ 24” O.C. IBC, IPC, NEC and ADA Sheathing: 7/16 Densdeck TX/LA/OK Approval Insulation: R-38 Kraft Insulation Additional State approval - see Pricing Catalog Ceiling: None - Option per Client Selection

Ceiling height to be 8’ AFF Roofing: 45mil EPDM Misc: Support Columns at Mateline Spaced as Req’d

INT/EXT DOORS Exterior Doors: None - Option per Client Selection Interior Doors: None - Option per Client Selection

WINDOWS Size: None - Option per Client Selection

INTERIOR FURNISHING Base/Wall Cabinets: None - Option per Client Selection Markerbd/Tackbd: None - Option per Client Selection

MEDICAL BUILDING FLEXX BOXX (DC32A-DC32J)

GENERAL BUILDING SPECIFICATIONS

Customer Acceptance

FRAME ELECTRIC Main Beams: 12” Jr. I-beam Load Center: None - Option per Client Selection Type: Outrigger Lights 1: None - Option per Client Selection Cross Member: 48” O.C. Lights 2: None - Option per Client Selection Hitch: Detachable Underslung Switches: None - Option per Client Selection Axles: Triple with Brakes as Needed Receptacles: None - Option per Client Selection

Raceway: None - Option per Client Selection FLOOR (50lb live load) Bottom Board: 0.040 Mobilflex PLUMBING Joists: 2x6 or 2x8, #2 SYP at 16” O.C. Water Closet: None - Option per Client Selection Insulation: R-22 Unfaced Lavatory: None - Option per Client Selection Decking: Single ¾ Sturd-I-Floor Plywood Sink: None - Option per Client Selection Floor Covering: None - Option per Client Selection Water Heater: None - Option per Client Selection Trim: None - Option per Client Selection Supply: None - Option per Client Selection Misc: NA Waste: None - Option per Client Selection

Misc: None - Option per Client Selection EXT/INT WALLS (140 mph/ 3 sec) Studs: 2x6, #2 SYP @ 16” O.C. Plates: 2x6, #2 SYP : (2) Top (1) Bottom HVAC Sheathing: None Heat/Cool: None - Option per Client Selection Wall Covering: 1/2 Vinyl Covered Gyp - Int Height8’ Duct: None - Option per Client Selection Insulation: R-13 Kraft (ext) Supply: None - Option per Client Selection Partitions: None - Option per Client Selection Return: None - Option per Client Selection Partitions: None - Option per Client Selection Thermostat: None - Option per Client Selection Siding/Trim: 3/8 LP Smartside Exhaust Fan: None - Option per Client Selection

Misc: None - Option per Client Selection ROOF Mateline Truss: Transverse Multilayer Plywood Beam STATE LABELS and APPROVALS Rafters: 2x8, #2 SYP @ 24” O.C. IBC, IPC, NEC and ADA Sheathing: 7/16 Densdeck TX/LA/OK Approval Insulation: R-38 Kraft Insulation Additional State approval - see Pricing Catalog Ceiling: None - Option per Client Selection

Ceiling height to be 8’ AFF Roofing: 45mil EPDM Misc: Support Columns at Mateline Spaced as Req’d

INT/EXT DOORS Exterior Doors: None - Option per Client Selection Interior Doors: None - Option per Client Selection

WINDOWS Size: None - Option per Client Selection

INTERIOR FURNISHING Base/Wall Cabinets: None - Option per Client Selection Markerbd/Tackbd: None - Option per Client Selection

OFFICE FLEXX BOXX (OB28E-OB28N)

GENERAL BUILDING SPECIFICATIONS

Customer Acceptance

FRAME ELECTRIC Main Beams: 12” Jr. I-beam Load Center: None - Option per Client Selection Type: Outrigger Lights 1: None - Option per Client Selection Cross Member: 48” O.C. Lights 2: None - Option per Client Selection Hitch: Detachable Underslung Switches: None - Option per Client Selection Axles: Triple with Brakes as Needed Receptacles: None - Option per Client Selection

Raceway: None - Option per Client Selection FLOOR (50lb live load) Bottom Board: 0.040 Mobilflex PLUMBING Joists: 2x6 or 2x8, #2 SYP at 16” O.C. Water Closet: None - Option per Client Selection Insulation: R-22 Unfaced Lavatory: None - Option per Client Selection Decking: Single ¾ Sturd-I-Floor Plywood Sink: None - Option per Client Selection Floor Covering: None - Option per Client Selection Water Heater: None - Option per Client Selection Trim: None - Option per Client Selection Supply: None - Option per Client Selection Misc: NA Waste: None - Option per Client Selection

Misc: None - Option per Client Selection EXT/INT WALLS (140 mph/ 3 sec) Studs: 2x6, #2 SYP @ 16” O.C. Plates: 2x6, #2 SYP : (2) Top (1) Bottom HVAC Sheathing: None Heat/Cool: None - Option per Client Selection Wall Covering: 1/2 Vinyl Covered Gyp - Int Height8’ Duct: None - Option per Client Selection Insulation: R-13 Kraft (ext) Supply: None - Option per Client Selection Partitions: None - Option per Client Selection Return: None - Option per Client Selection Partitions: None - Option per Client Selection Thermostat: None - Option per Client Selection Siding/Trim: 3/8 LP Smartside Exhaust Fan: None - Option per Client Selection

Misc: None - Option per Client Selection ROOF Mateline Truss: Transverse Multilayer Plywood Beam STATE LABELS and APPROVALS Rafters: 2x8, #2 SYP @ 24” O.C. IBC, IPC, NEC and ADA Sheathing: 7/16 Densdeck TX/LA/OK Approval Insulation: R-38 Kraft Insulation Additional State approval - see Pricing Catalog Ceiling: None - Option per Client Selection

Ceiling height to be 8’ AFF Roofing: 45mil EPDM Misc: Support Columns at Mateline Spaced as Req’d

INT/EXT DOORS Exterior Doors: None - Option per Client Selection Interior Doors: None - Option per Client Selection

WINDOWS Size: None - Option per Client Selection

INTERIOR FURNISHING Base/Wall Cabinets: None - Option per Client Selection Markerbd/Tackbd: None - Option per Client Selection

OFFICE COMPLEX MULTI-OCCUPANT RESTROOM MODULE (OB28O)

GENERAL BUILDING SPECIFICATIONS

Customer Acceptance

FRAME ELECTRIC Main Beams: 12” Jr. I-beam Load Center: 125A, 120V/240V, 1 phase, Exterior Type: Outrigger Lights 1: 2x4 Fixtures, T8 with elec ballasts Cross Member: 48” O.C. Lights 2: Combo emerg/exit light w/ remote head Hitch: Detachable Underslung Switches: 20A, Std white toggle type - Dual switching Axles: Triple with Brakes as Needed Receptacles: 20A, Std white, duplex type, GFI as needed

Raceway: EMT, Voice/Data roughin FLOOR (50lb live load) Bottom Board: 0.040 Mobilflex PLUMBING Joists: 2x8, #2 SYP at 16” O.C. Water Closet: Handicapped, tank type Insulation: R-21 Unfaced Lavatory: White vitreous, wall hung Decking: Single ¾ Sturd-I-Floor Plywood Sink: 15x15 Stainless steel, sink as shown Floor Covering: 1/8 VCT Throughout Water Heater: 20 gallon, electric Trim: 4” Vinyl cove base Supply: Type ‘L’ , hard copper Misc: Moist Stop Brick Flashing, Perimeter 12” Waste: Schedule 40 PVC

Misc: Floor drains, Roughin for EWC, Accessories EXT/INT WALLS (140 mph/ 3 sec) Misc: Fiberglass mop sink on legs Studs: 2x6, #2 SYP @ 16” O.C. Plates: 2x6, #2 SYP : (2) Top (1) Bottom HVAC Sheathing: None Heat/Cool: 3 Ton / 10KW Wall Hung Wall Covering: ½ Vinyl Covered Gyp / FRP(48”) in RR Duct: Foil faced fiberglass ductboard Insulation: R-21 Kraft (ext) R-11 Unfaced (int) Supply: Ducted Partitions: 2x4, #2 SYP @ 16” O.C. Return: Wall jump to plenum wall Partitions: 3/8 Plywood @ Mateline Walls Thermostat: Programmable, one per unit Siding/Trim: 3/8 LP Smartside Exhaust Fan: Fan/light combo within restrooms

Misc: NA ROOF Mateline Truss: Transverse Multilayer Plywood Beam STATE LABELS and APPROVALS Rafters: 2x8, #2 SYP @ 24” O.C. IBC, IPC, NEC and ADA Sheathing: 7/16 Densdeck TX/LA/OK Approval Insulation: R-38 Kraft Insulation Additional State approval - see Pricing Catalog Ceiling: 2x4 Grid @ 8’6” with Humiguard tiles Roofing: 45mil EPDM Misc: 6” Overhang Endwalls Only

INT/EXT DOORS Exterior Doors: 36”x 80” Tell Star Insulated 20 ga

metal frame 18ga and 7x22 vision panel Interior Doors 36”x 80” Hollow core w/ metal jamb

Hardware - Int privacy(RR), passage Hardware - Ext keylocks and deadbolts

WINDOWS Size: None

INTERIOR FURNISHING Base/Wall Cabinets: Prefinished wood base/wall cabinets with laminate

countertop per plan

Furniture and appliances by others

OFFICE COMPLEX MULTI-OCCUPANT RESTROOM MODULE (OB28W)

GENERAL BUILDING SPECIFICATIONS

Customer Acceptance

FRAME ELECTRIC Main Beams: 12” Jr. I-beam Load Center: 125A, 120V/240V, 1 phase, Exterior Type: Outrigger Lights 1: 2x4 Fixtures, T8 with elec ballasts Cross Member: 48” O.C. Lights 2: Combo emerg/exit light w/ remote head Hitch: Detachable Underslung Switches: 20A, Std white toggle type - Dual switching Axles: Triple with Brakes as Needed Receptacles: 20A, Std white, duplex type, GFI as needed

Raceway: EMT, Voice/Data roughin FLOOR (50lb live load) Bottom Board: 0.040 Mobilflex PLUMBING Joists: 2x8, #2 SYP at 16” O.C. Water Closet: Handicapped, tank type Insulation: R-21 Unfaced Lavatory: White vitreous, wall hung Decking: Single ¾ Sturd-I-Floor Plywood Sink: 15x15 Stainless steel, sink as shown Floor Covering: 1/8 VCT Throughout Water Heater: 20 gallon, electric Trim: 4” Vinyl cove base Supply: Type ‘L’ , hard copper Misc: Moist Stop Brick Flashing, Perimeter 12” Waste: Schedule 40 PVC

Misc: Floor drains, Roughin for EWC, Accessories EXT/INT WALLS (140 mph/ 3 sec) Misc: Fiberglass mop sink on legs Studs: 2x6, #2 SYP @ 16” O.C. Plates: 2x6, #2 SYP : (2) Top (1) Bottom HVAC Sheathing: None Heat/Cool: 3 Ton / 10KW Wall Hung Wall Covering: ½ Vinyl Covered Gyp / FRP(48”) in RR Duct: Foil faced fiberglass ductboard Insulation: R-21 Kraft (ext) R-11 Unfaced (int) Supply: Ducted Partitions: 2x4, #2 SYP @ 16” O.C. Return: Wall jump to plenum wall Partitions: 3/8 Plywood @ Mateline Walls Thermostat: Programmable, one per unit Siding/Trim: 3/8 LP Smartside Exhaust Fan: Fan/light combo within restrooms

Misc: NA ROOF Mateline Truss: Transverse Multilayer Plywood Beam STATE LABELS and APPROVALS Rafters: 2x8, #2 SYP @ 24” O.C. IBC, IPC, NEC and ADA Sheathing: 7/16 Densdeck TX/LA/OK Approval Insulation: R-38 Kraft Insulation Additional State approval - see Pricing Catalog Ceiling: 2x4 Grid @ 8’6” with Humiguard tiles Roofing: 45mil EPDM Misc: 6” Overhang Endwalls Only

INT/EXT DOORS Exterior Doors: 36”x 80” Tell Star Insulated 20 ga

metal frame 18ga and 7x22 vision panel Interior Doors 36”x 80” Hollow core w/ metal jamb

Hardware - Int privacy(RR), passage Hardware - Ext keylocks and deadbolts

WINDOWS Size: None

INTERIOR FURNISHING Base/Wall Cabinets: Prefinished wood base/wall cabinets with laminate

countertop per plan

Furniture and appliances by others