cryogenics in clio masatake ohashi and the lcgt collaboration
DESCRIPTION
Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration. What is CLIO ?. CLIO is a cryogenic interferometer with 100m baseline in the Kamioka Mine. CLIO is a prototype for LCGT. CLIO objective is to demonstrate reduction of thermal noise by mirror cooling. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/1.jpg)
58th Fujihara Seminar 2009/05/28
Cryogenics in CLIOMasatake Ohashi and the LCGT collaboration
![Page 2: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/2.jpg)
58th Fujihara Seminar 2009/05/28
CLIO is a cryogenic interferometer with 100m baseline in the Kamioka Mine.
CLIO is a prototype for LCGT.
CLIO objective is to demonstrate reduction of thermal noise by mirror cooling.
What is CLIO ?
![Page 3: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/3.jpg)
Illustrated by Dr. Miyoki
![Page 4: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/4.jpg)
58th Fujihara Seminar 2009/05/28
Contents
• CLIO Outline– Sapphire Mirror– Cryogenic Suspension System– Cryostat and Cooling Technique
• Status of CLIO– Present Status as a prototype of
LCGT
• Summary
![Page 5: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/5.jpg)
58th Fujihara Seminar 2009/05/28
Sapphire Mirror
![Page 6: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/6.jpg)
58th Fujihara Seminar 2009/05/28
CLIO Sapphire Mirror
Substrate: Crystal Systems (US)
Polish: CANON (Japan)
Coating: JAE (Japan) R=99.9%
Diameter 100mm Thickness 60mm (same as TAMA mirrors)
![Page 7: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/7.jpg)
58th Fujihara Seminar 2009/05/28
Sapphire Mirror- Absorption -
Absorption of laser light is important factor for mirror cooling.
We need better quality sapphire substrates.
LCGT requirement : substrate 20ppm/cm (not achieved) coating 1ppm (OK)
![Page 8: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/8.jpg)
58th Fujihara Seminar 2009/05/28
Sapphire Mirror- Mechanical Quality Factor -
Over 108 is obtained at low temperature.
Measured by Dr. Uchiyama
20K300K
Suspended by double sapphire wires
![Page 9: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/9.jpg)
58th Fujihara Seminar 2009/05/28
Sapphire Mirror- Dissipation of the Coating film -
Loss A
ng
le
Temperature [K]Dissipation seems to be almost independent of Temperature
Measured by Dr. K. Yamamoto
![Page 10: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/10.jpg)
58th Fujihara Seminar 2009/05/28
Cryogenic Techniques
![Page 11: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/11.jpg)
58th Fujihara Seminar 2009/05/28
Cryogenic Technique- Estimated Heat Generation in the Mirror -
T=20 K
q=290 mW ・ Design Safety factor
Mirror substrate : SapphireSuspension rods : Sapphire
Exhaust heat
![Page 12: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/12.jpg)
58th Fujihara Seminar 2009/05/28
CLIO Cryostat for end mirror
![Page 13: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/13.jpg)
58th Fujihara Seminar 2009/05/28
Low vibration Pulse Tube refrigerator
developed by KEK and SUMITOMO
![Page 14: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/14.jpg)
58th Fujihara Seminar 2009/05/28
8.8K45K
63K
12.9K
Cooling test and achieved temperature
Several days are necessary for mirror cooling.
Measured by Dr. Uchiyama
![Page 15: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/15.jpg)
58th Fujihara Seminar 2009/05/28
300K Radiation in vacuum pipes
Radiation shield (40K)Mirror (20K)
300K Radiation( straying )
300K Radiation from inside of vacuum pipes warms mirrors
Serious Problem for cooling
Radiation shield, Baffles, …
![Page 16: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/16.jpg)
58th Fujihara Seminar 2009/05/28
Radiation Shields (cloistered mirror)
Radiation shield for mirrors
![Page 17: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/17.jpg)
58th Fujihara Seminar 2009/05/28
Cryogenic suspension system
Mirror
Intermediatemass
Basic design is double pendulum
![Page 18: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/18.jpg)
58th Fujihara Seminar 2009/05/28
Cooling method by a cryocooler
![Page 19: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/19.jpg)
58th Fujihara Seminar 2009/05/28
Cooling procedure
Cooling shortens length of suspension by 2mm STEP1
cooling mirror alignment
STEP4 cooling mirror alignment
STEP2 cooling mirror alignment
STEP3 cooling mirror alignment
![Page 20: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/20.jpg)
58th Fujihara Seminar 2009/05/28
Current status of CLIO
![Page 21: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/21.jpg)
Noise budget at room temperature
58th Fujihara Seminar 2009/05/28
Thermal noise of suspension
Thermal noise of mirror
Current sensitivity is limited by thermal noises
![Page 22: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/22.jpg)
58th Fujihara Seminar 2009/05/28
Expected Noise Spectrum at 20K
Frequency [Hz]100 1K10 10K
10-21
10-20
10-19
10-18
10-17
10-16
Shot Noise
Suspension Thermal Noise@300K
Mirror Thermal Noise@300K
SQL
Total@300K
Total@20K
This curve is already realized
We started mirror cooling last week.
![Page 23: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/23.jpg)
Today’s DATA
58th Fujihara Seminar 2009/05/28
Preliminary
One mirror is cooled to 14K.
![Page 24: Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration](https://reader035.vdocuments.net/reader035/viewer/2022070416/5681528c550346895dc0b0da/html5/thumbnails/24.jpg)
58th Fujihara Seminar 2009/05/28
SUMMARY
Cryogenic prototype CLIO is
in commissioning phase.
Cryogenic interferometer is feasible. But we have to improve some points, especially, the combination of heat transfer and vibration isolation is important.