Page 1 of 16 MADE IN USA IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible Read, understand, and follow all safety information and instructions in this manual before using or servicing this product. Retain these instructions for future reference. CSW-12-VD Portable Evaporative Cooler A Product of Advanced Radiant Systems, Inc. www.cool-space.com [email protected]

Upload: others

Post on 27-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 1 of 16

MADE IN

USA

IMPORTANT SAFETY INFORMATION INSIDE

• Serious injury or death possible

• Read, understand, and follow all safety information and instructions in this manual before using or servicing this product.

• Retain these instructions for

future reference.

CSW-12-VD Portable Evaporative Cooler

A Product of Advanced Radiant Systems, Inc.

www.cool-space.com [email protected]

Page 2: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of
Page 3: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 2 of 16

INDEX

Index Page 2 Signal Word Definitions Page 2 General Description and Use Page 3 Specifications Page 4 Wiring Page 4 How Evaporative Cooling Works Pages 5 & 6 Unpacking Page 6 & 7 Assembly Instructions Pages 7 Connecting the Water Supply Page 8 Connecting the Electrical Supply Page 8 Start-Up Procedure Page 9 Maintenance Pages 10 & 11 Troubleshooting Page 12 Replacement Parts Page 13 Warranty Page 14

ATTENTION: The table to the right provides definitions of the signal words that can be found throughout this manual. These signal words are used to express the severity of the hazard at hand. The signal words are generally used in conjunction with safety symbols that correspond to the text for that particular hazard. As you read this manual, refer back to this table when you are unsure of the signal word definition.

Page 4: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 3 of 16

ELECTRICAL SHOCK HAZARD FIRE HAZARD

• Serious injury or death may

occur. • Do not use in locations

containing hazardous or explosive atmospheres.

• Do not use outdoors in wet

conditions and in unprotected locations.

This unit is a compact, self-contained, high-efficiency portable evaporative cooler capable of lowering existing temperatures by as much as 26 degrees. The unit draws air across water-saturated high-efficiency cooling pads, causing a gradual evaporation of the water, thereby removing heat from the air. The 10-gallon reservoir provides hours of operation without a water supply. Evaporative cooling is also environmentally friendly, since it does not use chlorofluorocarbons (CFC’s), and therefore does not contribute to ozone depletion.

GENERAL DESCRIPTION & USE

Benefits

• Significantly reduces air temperatures and generates a cooler and more comfortable working environment

• Compact portable cooling system with quiet fan axial blower design

• Easy to operate and maintain, plus an economical solution for low cost spot cooling

• Cooling media pad contains a paper treated CELdek material with a rigid protective edge coating (Munters MI-T-edg ®) to extend the life of the pad, plus provide added weather and algae protection, durability, and formulated to withstand repeated cleaning without damage to the pad

• Ready to plug into any 120VAC receptacle and hooks up to any standard garden hose for direct water supply

• Applications would include workshop environments, material handling areas, automotive shops, office areas, and many more!

Features

• Reduces air temperatures up to 26-degrees

• Cools an area of approximately 900 sq. ft. (30’ x 30’)

• 4” thick highly efficient cooling pads • Four 3” diameter swivel bearing

wheels, two locking, for easier portability and positioning over many surface types.

• Indented top for tool & product placement

• Internal reservoir with water capacity of 10 -gallons for remote applications, includes oversize inlet opening for reservoir filling.

• Auto fill hose connector for continuous use with a garden hose

• Includes 17’ long cord with ground fault 120 volt plug

Page 5: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 4 of 16

SPECIFICATIONS

Air Volume 3800-CFM (2200-CFM Low), 700-FPM @ 6FT Fan Motor Variable Cooling Media Type CELdek high cellulose paper treated media pads for effective cooling and resistance

to edge degradation. Cross-fluted design induces highly turbulent mixing of air & water for optimum cooling and enhanced self-cleaning.

Cooling Media Size 18" x 18" and 4" thick Water Reservoir Capacity 10 - gallons Switch Variable Cord 17’ long, 18 ga. 3-conductor cord GFCI Protective Guard CSW-12VD Oscillating Power Supply 120-VAC; 60 Hz; 3-Amps Unit Dimensions 21-1/4" wide x 27-1/2" tall x 23” deep Unit Weight 51 lbs. (without water in reservior) Water Supply Standard garden hose connection or hand fill reservoir

WIRING

Page 6: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 5 of 16

To understand how the portable evaporative cooler works a basic understanding of psychrometrics is necessary. Psychrometrics is the branch of thermodynamics devoted to the study of air and water vapor mixtures. The psychrometric chart is a graphical representation of properties of moist air. To illustrate how the unit operates, some of the relevant properties are described in this section followed by a sample application.

Dry-bulb temperature is measured with a thermometer. Dry-bulb temperature lines on the psychrometric chart are the vertical lines. The wet bulb temperature is the lowest temperature that can be reached by evaporating water into the air.

Dew-point temperature is the temperature to which a given sample of air must be cooled so that moisture will start condensing out of it. When air is saturated, the dry-bulb, wet-bulb, and dew-point temperatures will all be equal. The horizontal lines show the dew-point temperature on the psychrometric chart.

Relative humidity is the amount of moisture in the air relative to the amount of moisture the air would hold if saturated at that dry-bulb temperature. Percent humidity is not the same as relative humidity and is not used in HVAC design. This graph shows the relative humidity curves on the psychrometric chart.

HOW EVAPORATIVE COOLING WORKS

DRY BULB TEMP WET BULB TEMP

DEW POINT TEMP

Page 7: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 6 of 16

Inspect your unit for any concealed shipping damage and report it immediately to your carrier. In addition to our evaporative cooler the following items are included in a hardware pack and will need to be installed before operating the unit.

UNPACKING

Non-Swivel w/ lock (qty. 2)

The following example illustrates the use of the psychrometric chart as it relates to evaporative cooling. Since all of the items described above are properties, any two of them describe a state point on the psychrometric chart. Once this point is determined, the values of all the other properties can be read from the chart. The example below shows a Mollier type psychrometric chart for atmospheric pressure. The dot shown is a state point and the following properties are known about the air/water mixture at this state.

Take the air/water mixture described by the state point above, with a dry-bulb temperature of 97° and 43% relative humidity, for example. As the air passes through the cooling media on the unit, moisture is added to the air increasing the relative humidity. This increase in relative humidity brings a decrease in dry bulb temperature. When the relative humidity is raised to 70%, the dry bulb temperature has dropped to 86°F. When the humidity level approaches 100%, the dry bulb temperature has dropped nearly 20°F to 78°F.

78°F

71°F

97°F

43%

WET BULB TEMP

DRY BULB TEMP

Dry-bulb temperature: 97° Wet-bulb temperature: 78° Dew-point temperature: 71° Relative humidity: 43%

Swivel Casters: (qty. 2)

Page 8: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 7 of 16

Casters (4)

Screws (2) Bottom of unit

Screws: (qty. 8)

ASSEMBLY

Wheel Assembly Tools required: 7/16” nut driver

1.) Turn unit over and place on cardboard to protect finish

2.) Align wheel plate with embedded nuts on bottom of housing

3.) Attach using (2) screws 4.) Repeat steps 2 and 3 for each wheel

ELECTRICAL SHOCK HAZARD

• Serious injury or death may occur.

• Disconnect from electrical

supply before and during assembly of this product.

Pad Installation 1.) Remove pad retainer bar 2.) See page 12

Pads

Washer (2)

Screws (2)

Pad retainer bar

Page 9: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 8 of 16

Garden hose connection: This unit comes equipped with pressure regulator a female garden hose adapter that can be connected to any standard garden hose. The float will automatically maintain the correct water level. DO NOT over tighten as this may cause the float assembly to rotate resulting in over filling of reservoir. Stand-alone: This unit can also be manually filled and moved into position. To fill the unit; simply remove the fill cap located on the side of the housing, fill with water, and replace the cap. NOTE: Do not fill the reservoir past the max water line. Water can easily spill from inside the unit when rolling the cooler on uneven surfaces or if the reservoir is overfilled.

-Do not connect this unit to any water source where the water pressure exceeds 60 psi. This will cause permanent damage to the unit. Pressures above 60 psi must use a pressure regulator. A pressure reducing valve is installed on the float inlet. -Do not fill the reservoir past the MAX water level line indicator.

CONNECTING THE WATER SUPPLY

ELECTRICAL SHOCK HAZARD

• Serious injury or death may occur.

• Disconnect from electrical

supply before and during assembly of this product.

This cooler comes equipped with a 120-volt power supply cord and should only be plugged into a 120 VAC, 60 Hz branch circuit that includes a properly sized over current protection device (fuse or circuit breaker). Consult a licensed electrician if there is a question about adequacy of the electrical supply. EXTENSION CORDS Use only 3-conductor extension cords of 14AWG to 25 ft., 12AWG to 50 ft. & 10AWG to 100ft. length maximum. Do not use the extension cord powering this cooler to power any other appliances or electrical loads.

CONNECTING THE ELECTRICAL SUPPLY

ELECTRICAL SHOCK HAZARD

• Serious injury or death may occur.

• Make certain the power

source conforms to specifications on data label.

• Do not connect plug to power

supply without cooling pads installed and fastened in place.

Page 10: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 9 of 16

Initial start-up:

Clean out the Sump: Remove any foreign material in the sump before start up. It is normal for some debris to accumulate in the sump. It is best to flush out the sump with water to clear any debris.

Filling the unit with water: Once the unit has been hooked up to a water source, turn the water supply valve on and the unit will fill with water. The float valve will shut off the water flow when the reservoir is filled.

START-UP PROCEDURE

Do not operate the pump when the reservoir is dry. This will cause the pump to fail and also void the warranty.

There are 4 factors to consider when determining where to place your evaporative cooler.

1. Fresh air supply: The inlet side of the unit (pad side) requires a constant, uninterrupted supply of fresh air for maximum performance. A distance of 3 ft. of clear space is recommended.

2. Discharge airflow: The cool air discharged from the unit should be free of obstruction to allow the air to

circulate in order to maximize the cooling zone.

3. Ventilation: Allow cooled air to circulate away from discharge area of cooler. This ensures that the unit does not re-circulate air that has already been through the evaporative cooling process.

4. Placement: The unit must be placed on a level surface to operate correctly. The units create an oval shaped

air pattern that can reach out as far as 20 feet. Obstacles such as racks and workbenches may interfere with the cooling zone. An attempt should be made to locate the unit in such a manner that interruption of the air pattern is held to a minimum. Multiple units may be required to cover large areas.

ELECTRICAL SHOCK HAZARD

• Serious injury or death may occur.

• Disconnect from electrical

supply before servicing this product.

Annual start-up: At the beginning of each cooling season follow the same procedures as the initial start-up with some possible exceptions. If the media was removed for the winter, it will have to be replaced (note instructions below on media replacement). Check the condition of the media. If the flutes of the media are clogged with buildup of alkali deposits or are otherwise damaged, consider replacing the media. This is the best time to make this decision while the unit is not being used and may not be as critically needed.

Starting the pump: Allow the reservoir to fill before turning the pump on. Once the reservoir is full, the pump switch may be turned to the ‘ON’ position.

Initial Washing of the Cooling Media: The media should be washed for several hours by running the pump without any airflow through the media. This washing action will clean out any debris in the media as well as reduce any odor and improve wetting ability.

Break in Period for Cooling Media: The media will reach its peak operating condition after about 100 hours of operation. The chemical constituency rigidifying agents in the media will then be set and will not leach out further. Ignore any coloration in the water during this initial period.

If a strong odor persists, run the pump to flush the media with water, without airflow through the media, until the odor disappears.

Page 11: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 10 of 16

ODOR CONTROL

One of the few inconvenient aspects of evaporative cooling is the control of unpleasant odors. There are two primary causes of these odors:

1. Initial wetting of new pads 2. Poor maintenance and storage behaviors and/or poor quality water.

Your EVAP-series cooler has been delivered with pads that have never been wet. The same is true of replacement pads. The resins and adhesives used to create these pads will give off an odor during initial use that can last for a week or more. This can’t be avoided but it can be minimized. As the cooler is used over time, algae and bacteria growth can occur. This can also be minimized. Below are recommended actions to be taken to address noticeable odor due to the above causes.

Odor from Initial Wetting of Pads

1. At first use of your new cooler or after installing new replacement pads, make certain there is lots of fresh air available to the cooler.

2. Add one capful of liquid laundry fabric

softener to the water in the bottom reservoir of the cooler.

3. The odor from initial wetting of pads

should disappear in approx. two weeks of operation.

4. If odor does not disappear after two

weeks of operation, follow the steps for “Periodic Odor Maintenance”.

Periodic Odor Maintenance

1. Make certain the cooler is full of fresh water.

2. Flush the pads for 3 – 4 hours by

operating the pump only with the fan off. Adjust flow control valve for maximum rate of recirculating water flow.

3. After flushing, empty the reservoir

through the front drain and clean out any residual particulate in the reservoir.

4. Refill reservoir with fresh water and

proceed to use the cooler.

5. Repeat the above steps as necessary to eliminate odor.

Page 12: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 11 of 16

MAINTENANCE

Algae/Bacterial Control Control with chemicals. Chlorine is the most commonly used chemical to control organisms. It is potentially dangerous and should be used with great caution. One of the best methods to introduce chlorine into the water circulation system is on the pressure side of the pump on a continual or timed basis. Note: Consult water treatment experts before attempting chemical water treatment. Neither media manufacturers’ nor equipment manufacturers’ warranties cover damage due to chemical water treatment and warranty may be voided when chemicals are used. Other chemicals suitable for organism control include hydrogen peroxide, bromine based oxidizers, and other commercial products. It is important to maintain a 6 to 9 pH level after treatment. Control without chemicals. With water, sunlight, and nutrients, most organisms can survive. The water in the media can be allowed to dry out and any organisms living in the media will become dry and flaky. This can then be flushed out at the next start up of the unit. Shading the media will prevent the sunlight from encouraging the growth of organisms. Nutrients are available from the air itself, however in some instances, phosphates and fertilizers are carried in the air stream and should be avoided. Flushing the media with fresh water and dumping the sump water periodically is the best preventative measure that can be taken. This flush and dump action will actually prevent alkali deposits and algae/bacteria from growing. There are also some non-recirculating water distribution systems available that provide a constant flushing/dumping action.

Water Chemistry Hard water contains relatively large amounts of minerals, primarily calcium. A sample of water can contain only a specific maximum amount of dissolved solids in solution. If these concentrations increase beyond a certain level, the excess minerals precipitate out as a solid material. This precipitation will appear as the familiar white residue left on the face of the media. It is commonly referred to as alkali, calcium depositions or salts. The same process occurs in the desert when water collects in depressions and since only pure water evaporates the minerals are left behind. These are commonly referred to as “dry lakes” or “salt flats”. The build up of these minerals on the face of the media does not because a problem until the airflow is restricted. There is no easy way to remove these deposits. The best solution to this problem is preventive rather than corrective action and usually requires simple actions such as media flushing with fresh water and periodic dumping of the sump water. Soft water is on the opposite side of the scale for water chemistry as compared to hard water. Basically, removing or diluting the effects of the calcium in the water creates soft water. Soft water is not to be confused with pure water. Pure water does not contain or contains very small amounts of minerals found in either hard or soft water. While hard water can leave deposits in the media, soft water can cause harm to the media by leaching out the rigidifying agents. Either water condition can have some adverse effects on the media. PH Range. A pH range of 6 to 9 is the acceptable range for the media, the closer to the center the better. The re-circulating system of the water distribution allows the mineral content in the sump water to become more and more intensive because the same water is re-circulating. The pure water is lost to evaporation while the minerals just continue to build up. TDS is the abbreviation for “Total Dissolved Solids” and represents, as the name implies, a way of identifying a measurement of the mineral content.

CHEMICAL BURN HAZARD POISONOUS GAS HAZARD

• Serious injury or death may

occur. • Read, understand and follow

all chemical manufacturers’ instructions when using the chemicals noted in these pages.

Page 13: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 12 of 16

CHEMICAL BURN HAZARD POISONOUS GAS HAZARD

• Serious injury or death may

occur. • Read, understand and follow

all chemical manufacturers’ instructions when using the chemicals noted in these pages.

Removing the cooling media: In order to perform any maintenance on internal components the cooling pads must be removed to access the inside of the unit. Media removal / replacement is simple, if you follow these instructions! The media is soft when wet so be very careful when handling. The media has two separate flute angles, which are transverse to each other and alternate across the face of the media. One flute is 45° and the other is 15°. The alignment of the flute arrangement in relation to the direction of airflow is critically important. The 45° flute must be aligned upwards in the direction of the airflow. The 15° flute must be aligned downwards in the direction of the airflow.

1. Using a 5/16” nut driver, remove the (2) screws holding the pad retainer bracket in place. Save all hardware.

2. The pad may be tilted out of the unit and lifted out of the drain tray.

Note: Reinstall pads correctly; refer to sides of pad material for airflow direction.

To keep your unit operating at peak efficiency, ensure that the cooling pads are kept clean and dust-free. Dust and other particles have an adverse effect on the media’s ability to introduce water into the air stream. If the pad surface becomes dirty or dusty, clean with a soft brush and water. Daily maintenance: At start-up: It is best to run the pump several minutes before the fan is started to clean out any debris on the media. At shut-down: When shutting down your evaporative cooler at the end of each workday, the pump should be turned off approximately 15 minutes before the fan is turned off. This will allow the pads to drain and dry out. This simple guideline will ensure long and efficient pad life as well as help to control mildew and bacteria growth. Periodic maintenance: Depending on how often the unit operates, this procedure should be performed anywhere from every week for heavy use to monthly for light use.

1. Drain reservoir. 2. Remove cooling pads. 3. Clean out reservoir with either a towel or wet/dry

vacuum. 4. Reinstall pads and pad retainers.

ELECTRICAL SHOCK HAZARD

• Serious injury or death may occur.

• Disconnect from electrical

supply before servicing this product.

Annual shutdown / Storage: 1. Wash down the media to flush out all the debris. 2. Open the drain in the sump to drain out any

standing water. 3. Wash the interior of the unit to remove any

algae or micro-organisms as well as calcium deposits. A weak dilution of muriatic acid will help clean the alkali (calcium) deposits. Commercial chlorine will kill and clean out the algae.

4. Store the unit in a dry area and cover if possible to prevent dust build-up.

Airflow Direction

Screws

Pad retainer Pad material

Page 14: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 13 of 16

TROUBLESHOOTING

Fan System: The fan system consists of two primary elements: Fan Blade and Motor Problem Check Solution

Fan won’t run and makes no sound. Power cord, extension cord, switches, and circuit breaker.

Reconnect power or extension cord. Reset breaker.

Fan motor won’t run and makes a humming sound.

Motor stalled (will not turn by hand). Replace motor.

Breaker trips or fuse blows when fan is started.

Motor stall. Check power source for min. 115v/10 amp. Extension cord adequacy.

Replace motor. Upgrade power supply. Replace with heavier cord.

Motor overheating and shutting off. Restarting several minutes later.

Extension cord gauge too small. Inlet air obstructed or too close to wall. Faulty motor.

Replace with heavier cord. Provide additional inlet clearance. Replace motor.

Fan motor won’t run and switch makes soft clicking sound.

Switch making good contact. Replace switch.

Water Systems: The water delivery system consists of four primary elements: Water Hose, Float Assembly, Pump, and Water Distribution Channel. Problem Check Solution Floor at side of the unit is wet. Water inlet hose is loose at supply

hose. Tighten connections and/or replace hose washers.

The unit overflows from reservoir. Float valve hose is loose at bulkhead fitting or at float valve. Water pressure is too high to allow float valve to shutoff (60psi max). Float valve is not seating properly.

Tighten connections and/or replace hose washers. Reduce water pressure by adding an inline pressure reducer. Check float valve. Replace float

Water leaking from drain valve. Make sure drain nut is secure. Tighten drain nut. Too many dry streaks in the pads. Holes in water distribution tray are

blocked. Remove distribution tray and clean

Water spitting from the unit. Hose connection loose. Tighten hose. Replace hose and washer.

Pump motor will not run when switch is turned on.

Check switch, cord and circuit breakers.

Replace switch and reset breaker.

ELECTRICAL SHOCK HAZARD

• Serious injury or death may occur.

• Disconnect from electrical

supply before servicing this product.

Page 15: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 14 of 16

ITEM NO.

DESCRIPTION PART NO. QUANTITY

1 FAN ASSEMBLY CS-F12-VD 60HZ 1 2 ON/OFF SWITCH CS-E110 1 3 VARIABLE SWITCH CS-E187-VD 60HZ 1 4 PUMP CS-E12-101 1 5 FLOAT CS-P053.1 1 6 PAD MEDIA KIT CS-A12-101 1

COMMON REPLACEMENT PARTS

DO NOT DISCARD FAULTY PARTS! THEY MUST BE RETURNED IN ORDER TO RECEIVE WARRANTY CREDIT

WARRANTY

WARRANTY Your COOLSPACE unit is guaranteed against any defective material or workmanship for a period of 12 months from your date of original purchase. Please call (800) 557-5716 to receive a returned goods authorization number to return and receive any defective parts. Shipping costs for returns are at the expense of the customer.

It is our goal to have satisfied Customers, and to provide you with any support you may need. If you have any questions about our product, operation or are having technical problems please call 1-800-557-5716.

IN CASE OF PRODUCT FAILURE:

Please have the following information ready when you call:1. Model Number and Serial Number.2. Proof of purchase.3. Description of the problem encountered with product.

SELLER'S LIABILITY

Seller will not be liable for any loss, damage, cost of repair, incidental or consequential damages of any kind, whether based on warranty, contract or negligence, and arising in connection with the sale, use or repair of the Products. Seller's maximum liability shall not in any case exceed the contract price for the Products claimed to be defective or unsuitable.

RETURNED GOODS Equipment may be accepted for return with in 90 days of shipment, when authorized by us with our return labels. Request necessary permission and special Return Authorization Tags. Currently listed equipment in new and unused condition, and in factory sealed cartons, may normally be returned for full credit less 25% (minimum charge $20.00) charge for handling, repacking and restocking, and less transportation charges both ways, at net prices prevailing at time of purchase or time of return, whichever is lower. Advanced Radiant Systems, Inc., however, reserves the right to refuse any return, at our discretion, and is not responsible for error. All special, custom made or equipment with special finishes, and modified versions of cataloged numbers are not returnable. All returned merchandise is subject to inspection. Unsalvageable and damaged merchandise will be credited at salvage value or less costs of repairs.

DAMAGED GOODS

Minimum charge on replacement will be waived if order is accompanied by copy of proof of claim submitted to carrier. No repair, replacement, or other adjustment by the customer is authorized by us, unless so stated in writing by our Sales Service department.

Page 16: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of
Page 17: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 15 of 16

COOLSPACE® Warranty Form

Date Purchased: __________________________

Purchased From: _______________________________________________

Model Number: CSW- __________ Serial Number: ___________________

Company: _____________________________________________________

Contact: _______________________________________________________

Address: _______________________________________________________

Phone Number: __________________ Fax Number: ___________________

You must complete this form and return within fifteen (15) days of initial purchase to validate your cooler’s warranty. Please call COOLSPACE® (800) 557-5716 if you have questions. Please fax or mail this completed form to:

Fax to: (317) 485-0118

Mail to: COOL-SPACE® Warranty Dept. 315 N. Madison St. Fortville IN 46040 Submit online: www.COOL-SPACE.com under the CONTACT tab.

www.cool-space.com

Page 18: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of
Page 19: CS WAVE Owners Manual 2014 - Air Conditioningflnac.com/pdfs/coolspace/cool-space-wave12-operation-manual.pdf · psychrometric chart is a graphical representation of properties of

Page 16 of 16

IMPORTANT NOTICE: DO NOT RETURN TO PLACE OF PURCHASE.

Please call 800-557-5716 for technical service support and warranty information

315 North Madison Street, Fortville IN 46040 Phone: 317-577-0417 – Fax: 317-485-0118

1-800-557-5716 www.cool-space.com [email protected]

REV 06/14jw PN CSW-VD MANUAL