csm2 and msrfl project: drainage layout plansplot date: 11 april 2013 - 11:01 a.m. plotted by: james...
TRANSCRIPT
FOR CONSENT
62236-A-C401 0
AMW TP
NJD TM
CMG
10.05.12
1:2000 (A3)
This Drawing must not beused for Construction unlesssigned as Approved
Date
CheckDrafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:17 October 2012 - 12:56 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings A\400 Drainage\62236-A-C401.dwgPlotted by: Annie Porteous
A3 Scale
SW_SDC
EXISTING BOUNDARY
SOAKPIT OVERLAND FLOW
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
LEGEND
W
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
FOR CONSENT
62236-A-C402
1
AMW TP
NJD TM
CMG
10.05.12
1:2000
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 9:04 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C402.dwg
Plotted by:
James Long
A3 Scale
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
W
BACKFILL EXISTING STOCKWATER RACE
SOAKPIT OVERLAND FLOW
INDICATIVE PROPOSED POND
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
LEGENDSANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
FOR CONSENT
62236-A-C403
1
AMW TP
NJD TM
CMG
10.05.12
1:2000
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 9:52 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C403.dwg
Plotted by:
James Long
A3 Scale
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
W
BACKFILL EXISTING STOCKWATER RACE
SOAKPIT OVERLAND FLOW
INDICATIVE PROPOSED POND
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
LEGEND
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
FOR CONSENT
62236-A-C404 0
AMW TP
NJD TM
CMG
10.05.12
1:2000
This Drawing must not beused for Construction unlesssigned as Approved
Date
CheckDrafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:17 October 2012 - 1:00 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings A\400 Drainage\62236-A-C404.dwgPlotted by: Annie Porteous
A3 Scale
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
LEGEND
W
BACKFILL EXISTING STOCKWATER RACE
SOAKPIT OVERLAND FLOW
INDICATIVE PROPOSED POND
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
FOR CONSENT
62236-A-C405 0
AMW TP
NJD TM
CMG
10.05.12
1:2000
This Drawing must not beused for Construction unlesssigned as Approved
Date
CheckDrafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:17 October 2012 - 1:01 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings A\400 Drainage\62236-A-C405.dwgPlotted by: Annie Porteous
A3 Scale
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
LEGEND
W
BACKFILL EXISTING STOCKWATER RACE
SOAKPIT OVERLAND FLOW
INDICATIVE PROPOSED POND
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
FOR CONSENT
62236-A-C406 0
AMW TP
NJD TM
CMG
10.05.12
1:2000 (A3)
This Drawing must not beused for Construction unlesssigned as Approved
Date
CheckDrafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:17 October 2012 - 1:03 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings A\400 Drainage\62236-A-C406.dwgPlotted by: Annie Porteous
A3 Scale
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
LEGEND
W
BACKFILL EXISTING STOCKWATER RACE
SOAKPIT OVERLAND FLOW
INDICATIVE PROPOSED POND
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
FOR CONSENT
62236-A-C408
1
DX TP
TM TM
GAP
16.10.12
1:2000
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:11 April 2013 - 11:01 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C408.dwg
Plotted by:
James Long
A3 Scale
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
W
BACKFILL EXISTING STOCKWATER RACE
SOAKPIT OVERLAND FLOW
INDICATIVE PROPOSED POND
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
LEGENDSANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
FOR CONSENT
62236-A-C411
1
DX TP
TM TM
GAP
16.10.12
1:5000
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 9:49 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C411.dwg
Plotted by:
James Long
A3 Scale
SW_SDC
SW_SDC
S
SW
HV HV
E
TELSTRA
TCOM TCOM
FO FO
C
EN EN
NG NG
FOR CONSENT
62236-A-C412
2
JAL TP
JR DGA
GAP
21.05.13
1:5000
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
W
BACKFILL EXISTING STOCKWATER RACE
SOAKPIT OVERLAND FLOW
INDICATIVE PROPOSED POND
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:21 May 2013 - 2:19 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C412.dwg
Plotted by:
James Long
A3 Scale
LEGENDLEGEND
CC
CC
CC
CC
CC
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CC
C
TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA
0 100 200 300 400 500 600
0
100
200
300
1100
1200
130014
00
0
100
200
0
0
WW
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
APPROXIMATE EXTENT OF 'NATURAL'1m GROUNDWATER CLEARANCE
APPROXIMATE EXTENT OF'NATURAL' 1m GROUNDWATERCLEARANCE
SUBSOIL DISPOSAL/GROUNDWATERDRAINAGE AREAROBINSONS OVERPASS RISING
MAIN TO DISPOSAL FIELD
ROBINSONS ROAD OVERPASSGROUNDWATER PUMPING WETWELL
STOCKWATER RACEUPSTREAM SIPHON
STRUCTURE
STOCKWATER RACE PIPEDADJACENT TO ROBINSONSROAD CUTTING
PROPOSED BUFFERSTORAGE DISPOSAL FIELD
APPROXIMATE EXTENT OF OVERLANDFLOW PROTECTION STORMWATER BUND TO CONTAIN
POTENTIALLY CONTAMINATED SITERUNOFF
STOCKWATER RACE PIPEDADJACENT TO CURRAGHSROAD CUTTING
EXISTING STOCKWATERRACE TO BE REMOVED
APPROXIMATE EXTENT OF OVERLANDFLOW PROTECTION
ROBI
NSON
S RO
AD
EXTENT OF WORKS - CSM2EXTENT OF WORKS - MSRFL
JOIN LINE - SHEET 1
JOIN LINE - SHEET 2
CURR
AGHS
ROA
D
ROBINSONS ROADOVERPASS
POTENTIALLY CONTAMINATED LAND.EXCAVATION TO BE MINIMISED IN THIS AREA
SUMP AND SOAKPIT FORMOUNTABLE KERB ANDCHANNEL DRAINAGE
N
LARGE PIPE (CONVEYANCEOF STORM FLOWS)
STOCKWATER RACE SIPHON(CONVEYANCE OF LOWFLOWS)
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 10:00 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C401.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C401
1
AW TP
NJD TM
CMG
10.05.12
1:2000
SW_SDC
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
600
700
800
900
1000 1100
1200
1300
1400
600
700
800
900
1000
1100
0
100
200
300
400
500
600
500
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE
STOCKWATER RACEUPSTREAM SIPHONSTRUCTURE
RECONTOUR SURFACEAS REQUIRED
PROPOSED CROSS DRAINTO SAFE GUARD AGAINSTOVERLAND FLOW FLOODING
EXISTING 750mmØ RC RAILWAY CULVERT(APPROXIMATE LOCATION)
OVERLAND FLOW UPSTREAM SIPHONSTRUCTURE SIPHON ENTRY. APPROX200mm BELOW OUTSIDE LANE LINELEVEL OF CARRIAGEWAY
SCRUFFYDOMEMANHOLE
PROPOSED STORMWATERBUND
JOIN LINE - SHEET 1JOIN LINE - SHEET 2
JOIN LINE - SHEET 2
JOIN LINE - SHEET 4
MAINTENANCEACCESS
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:11 April 2013 - 9:46 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C402.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C402
1
AW TP
NJD TM
CMG
10.05.12
1:2000
E EE E
EE
E EE E E E
EE
EE
EE
EE
EE
E
EE
EE
EE
EE
EE
EE
EE
E
EE
EE EE EE EE EE EE EE EE EE EE EE EE E
E
E E
E
E
E
TRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA
1100
600
700
40 0
500
0100
0
0
100
600
70 0
800
0100200
300
400
500
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_ SDC
JOIN LINE - SHEET 2
JOIN LINE - SHEET 3
N
JONES ROAD
C S M 2
WATERHOLES ROAD
DAWSONS ROAD
JONES ROAD
M A I N S O U T H R O A D ( S H 1 )
This Drawing must not beused for Construction unlesssigned as Approved
Date
CheckDrafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:17 October 2012 - 1:33 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C403.dwgPlotted by: Annie Porteous
A3 Scale
FOR CONSENT
62236-B-C403 0
AW TP
NJD TM
CMG
10.05.12
1:2000
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
LEGEND
W
BACKFILL EXISTING STOCKWATER RACE
INDICATIVE PROPOSED POND
SURFACE WATER SOAKAGE AREA
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
PROPOSED RISING MAIN
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
1300
1400
1500
1600
1700
1800
1900
2000
0
100
200
300
400
200
300
WATERHOLES ROAD
J OIN L INE - SHEET 2J OIN L INE - SHEET 4
N
JOIN
LINE
- SH
EET
15
JOIN
LINE
- SH
EET
4
JOIN
LINE
- SHE
ET 5
JOIN
LINE
- SHE
ET 4
WATERHOLES ROAD
C S M 2
WATER
HOLES ROAD
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
EE
EE
EE
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
EE
E E
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE
STOCKWATER RACEDOWNSTREAM SIPHONSTRUCTURE
PROPOSED STORMWATERBUND
PROPOSED KERBAND CHANNEL
W
W
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
W
PROPOSED CROSS DRAIN TO SAFEGUARD AGAINST OVERLAND FLOWFLOODING
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
PROPOSED STORMWATERBUND
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
WATERHOLES ROADUNDERPASS
This Drawing must not beused for Construction unlesssigned as Approved
Date
CheckDrafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:17 October 2012 - 1:34 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C404.dwgPlotted by: Annie Porteous
A3 Scale
FOR CONSENT
62236-B-C404 0
AW TP
NJD TM
GARY PAYNE
29.08.12
1:2000
EXISTING BOUNDARY
INDICATIVEPROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED DRY SWALE
PROPOSED SWALE
PROPOSED FLUME
PROPOSED CATCHPIT
PROPOSED DRAIN
PROPOSED STOCKWATER RACE
PROPOSED HEADWALL
INDICATIVE AREAS OFENVIRONMENTAL SIGNIFICANCE
PROPOSED SOAK PIT LOCATION
LEGEND
W
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
E
E
E
E
E
E
E
E
2100
2200 2300
2400
2500
2600
2700
2800
500
HAMPTONS ROAD
WATERHOLES ROAD
N
JOIN
LINE
- SH
EET
5
JOIN
LINE
- SH
EET
4
JOIN LI
NE - SH
EET 5
JOIN LI
NE - SH
EET 1
5
JOIN
LINE
- SH
EET
6JO
IN LI
NE -
SHEE
T 5
W
W
W
W
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
PROPOSED STORMWATERCROSS DRAIN
PROPOSED STORMWATERBUND
PROPOSED STORMWATERBUND
WATERHOLES ROAD
STORMWATER RACE TO BEREALIGNED
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 11:43 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C405.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C405
1
AW TP
NJD TM
CMG
10.05.12
1:2000
SW_SDC
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
C
CC
CC
CC
C
C
C
C
CCCCCCCCCCC
EXISTING STOCKWATER RACETO BE INFILLED
NEW STOCKWATER RACE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
PROPOSED STORMWATERBUND
PROPOSED KERB AND CHANNEL
EXISTING STOCKWATERRACE TO BE INFILLED
EXISTING STOCKWATER RACETO BE INFILLED
PROPOSED CROSS DRAIN TOSAFE GUARD AGAINSTOVERLAND FLOW FLOODING
STOCKWATER RACE TOTERMINATE
2800
2900
3000
3100
3200
3300
3400
3500
200
300
500
600
WW
WW
W
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
WW
WW
W
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
WWWWWWWWWWWW
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
WW
WW
WW
W
W
W
WW
WW
W
N
JOIN
LINE
- SH
EET
6
JOIN
LINE
- SH
EET
5
JOIN
LINE
- SH
EET
7JO
IN LI
NE -
SHEE
T 6
TRENTS ROAD
TRENTS ROAD
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:3 July 2013 - 4:13 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C406.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C406
2
AW TP
NJD TM
CMG
10.05.12
1:2000
SW_SDC
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
3500
3600
3700
3800
3900 4000 4100
4200
300
500
C
C
C
C
C
C
C
C
C
C
C
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
STOCKWATER RACE UPSTREAMSIPHON STRUCTURE
STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE
REALIGN EXISTINGSTOCKWATER RACE
REALIGN EXISTINGSTOCKWATER RACE
PROPOSED STORMWATERBUND
BLAKES ROAD TERMINATES
PROPOSED STORMWATERBUND
PROPOSED STORMWATERBUND
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
OVERLAND FLOW UPSTREAMSIPHON STRUCTURETRENTS ROAD UNDERPASS
BLAKES ROAD TERMINATES
BLAKES ROAD
WW
SW_SDC
SW_SDC
SW_SDC
SW_S
DC SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDCSW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
WW
WW
WW
W
W
W
W
W
W
W SW_SDC
N
JOIN
LINE
- SH
EET
7JO
IN LI
NE -
SHEE
T 6
JOIN
LINE
- SH
EET
8
JOIN
LINE
- SH
EET
7
JOIN LINE - SHEET 16JOIN LINE - SHEET 7
TRENTS ROAD
TRENTS ROAD
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:3 July 2013 - 4:14 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C407.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C407
2
AW TP
NJD TM
CMG
10.05.12
1:2000
SW_SDC
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
4200
43 00
4 4 00
4500
4600 4700 4800
4900
0 100
0
100
200
300
NJO
IN LI
NE -
SHEE
T 8
JOIN
LINE
- SH
EET
7
J OIN
L INE
- SH
EET 9
J OIN
L INE
- SH
EET 8
C S M 2
SW_S
DC
SW_S
DC
SW_S
DC
SW_S
DC
SW_S
DC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
PROPOSED STORMWATERBUND
PROPOSED CROSS DRAIN TOSAFE GUARD AGAINSTOVERLAND FLOW FLOODING
PROPOSED STORMWATERBUND
This Drawing must not beused for Construction unlesssigned as Approved
Date
CheckDrafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:17 October 2012 - 1:43 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C408.dwgPlotted by: Annie Porteous
A3 Scale
FOR CONSENT
62236-B-C408 0
AW TP
NJD TM
CMG
10.05.12
1:2000
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
LEGEND
W
BACKFILL EXISTING STOCKWATER RACE
INDICATIVE PROPOSED POND
SURFACE WATER SOAKAGE AREA
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
PROPOSED RISING MAIN
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
4900
5000
5100
5200
5300
5400
5500
5600
100
200
300
400
500
600
0
100
200
0
100
200
300
300
400
500
600
0
100
0
100
0
100
200
300
400
500
300
400
500
600
700
SHAN
DS R
OAD
N
JOIN
LINE
- SH
EET
9JO
IN LI
NE -
SHEE
T 8
JOIN
LINE
- SH
EET
10JO
IN LI
NE -
SHEE
T 9
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
HVHV
HVHV
HVHV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
EE
EE
EE
EE
E
E
E
E E
EE
E
E
E
E
EE
SW_SDCSW_SDC
WW
WW
W
WW
SW_SDCSW_SDC
SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT
SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT
SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT
PROPOSED KERB AND CHANNEL
REALIGN LAND DRAINAGEWATER RACE
STOCKWATER RACETO BE INFILLED
SURFACE WATER SOAKAGEAREA DISPOSAL LEVELS TOBE LOWER THAN ADJACENTSWALE INVERT
SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT
RECONTOUR SURFACE AS REQUIRED
RECONTOUR SURFACE AS REQUIRED
RECONTOUR SURFACE AS REQUIRED
RECONTOUR SURFACE AS REQUIRED
RECONTOUR SURFACE AS REQUIRED
PROPOSED STORMWATERBUND WITH NIB WALL IFREQUIRED
PROPOSED KERB AND CHANNEL
PROPOSED CROSS DRAIN
PROPOSED KERB AND CHANNEL
PROPOSED CROSS DRAIN TOSAFE GUARD AGAINSTOVERLAND FLOW FLOODING
SHANDS ROAD UNDERPASS
NOTE: LOCATION OF OVERLAND FLOWPATHS TO BE CONFIRMEDBASED ON DETAILED SURVEY. ADDITIONAL SIPHONS MAY BEREQUIRED TO TRANSMIT OVERLAND FLOW UPSTREAM OFMOTORWAY UNDER THE OFF RAMP TO SOAKAGE
STOCKWATER RACE UPSTREAMSIPHON STRUCTURE
STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE
STOCKWATER RACE CHANGES TOLAND DRAINAGE RACEDOWNSTREAM OF SHANDS ROAD
MARSHS ROAD
SWALE TO DISPOSAL AREA
SWALE TO DISPOSAL AREA
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 12:52 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C409.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C409
1
AW TP
NJD TM
CMG
10.05.12
1:2000
SW_SDC
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
5600 5700 5800
5900
6000
6100
6200
6300
300
400100
200
300
400
500
600
700
800
400
500
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CC
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW W W W W W
W
W
W
W
SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT
PROPOSED KERB AND CHANNEL
LAND DRAINAGE RACE UPSTREAMSIPHON STRUCTURE
EXISTING STOCKWATERRACE TO BE INFILLED
EXISTING STOCKWATER RACE(LAND DRAINAGE RACE)
PROPOSED STORMWATER BUND
EXISTING STOCKWATER RACETO BE INFILLED
MARSHS ROAD UNDERPASS
MARSHS ROAD
N
JOIN
LINE
- SH
EET
10
JOIN
LINE
- SH
EET
9
JOIN
LINE
- SH
EET
11JO
IN LI
NE -
SHEE
T 10
REALIGN STOCKWATER RACE(LAND DRAINAGE RACE)
LAND DRAINAGE RACE DOWNSTREAMSIPHON STRUCTURE
REALIGN STOCKWATER RACE(LAND DRAINAGE RACE)
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 9:13 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C410.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C410
1
AW TP
NJD TM
CMG
10.05.12
1:2000
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
BACKFILL EXISTING RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
RETAIN EXISTING RACE
6300
6400 6500
6600
6700
6800
6900
7000
600
N
SPRINGS R
OAD
JOIN
LINE
- SH
EET
11
JOIN
LINE
- SH
EET
10
JOIN
LINE
- SH
EET
12
JOIN
LINE
- SH
EET
11
S
S
S
S
S
PROPOSED STORMWATERBUND OVERLAND FLOW UPSTREAM
SIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
PROPOSED STORMWATER BUND
OVERLAND FLOW UPSTREAMSIPHON STRUCTURE
PROPOSED STORMWATERBUND
CYCLE /WALKING TRAIL
OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE
PROPSOED CYCLEWAY
PROPSOED CYCLEWAY
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 12:59 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C411.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C411
1
AW TP
NJD TM
CMG
10.05.12
1:2000
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
BACKFILL EXISTING RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
RETAIN EXISTING RACE
7000
7100
7200
7300
7400
7500
7600
7700
7800
0
100
200
100
200
300
400
500
100
200
300
400
500
600
W
W
W
W
W
WWW
WW
WW
WW
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EEPROPOSED LAND DRAINAGE RACE
PROPOSED LAND DRAINAGE RACE
EXISTING FIELD DRAIN TO BE INFILLEDPROPOSED STORMWATER
TREATMENT AND DISPOSAL AREA
PROPOSEDDISPOSAL FIELD
PROPOSED CROSS DRAIN
PROPOSED KERB AND CHANNEL
REALIGN MONTGOMERIES DRAIN
STOCKWATER RACE UPSTREAMSIPHON STRUCTURE
STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE
EXISTING CSM1MUSHROOM PONDS
PROPOSED CROSS DRAIN
PROPOSED STORMWATER BUND
LOW LEVEL SLUICE VALVE AND MANHOLE, OUTLETPIPE TO MEET STORMWATER INFRASTRUCTURE ATCCC OWAKA BASIN OUTLET PIPE DISCHARGE POINT
SPRINGS ROAD UNDERPASS
ON RAMP
HALSWELL JUNCTION ROAD
SPRI
NGS R
OAD
JOHN PATERSON DRIVE
N
JOIN
LINE
- SH
EET
12JO
IN LI
NE -
SHEE
T 11
JOIN
LINE
- SH
EET
14JO
IN LI
NE -
SHEE
T 12
JOIN LINE - SHEET 12JOIN LINE - SHEET 13
-C425
PROPOSED CYCLEWAY
PROPOSED CYCLEWAY
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 1:01 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C412.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C412
1
AW TP
NJD TM
CMG
10.05.12
1:2000
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
BACKFILL EXISTING RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
RETAIN EXISTING RACE
CC
CC
CC
CC
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
S
S
SS
SS
S
S
S
S
EXISTING CCC HALSWELLJUNCTION ROAD POND
EXISTING CSM1 DRAINAGE TOBE RETAINED IN THIS AREA
0
100
200
0
100
SPRIN
GS ROA
D
HALSWELL JUNCTION ROAD
N
JOIN LINE - SHEET 12JOIN LINE - SHEET 13
SPRI
NGS
ROAD
WILMERS ROAD
This Drawing must not beused for Construction unlesssigned as Approved
Date
CheckDrafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:17 October 2012 - 2:12 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C413.dwgPlotted by: Annie Porteous
A3 Scale
FOR CONSENT
62236-B-C413 0
AW TP
NJD TM
CMG
10.05.12
1:2000
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
LEGEND
W
BACKFILL EXISTING STOCKWATER RACE
INDICATIVE PROPOSED POND
SURFACE WATER SOAKAGE AREA
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
PROPOSED RISING MAIN
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
7800
7900 8000 8100
8300 8400
8500
0 100200
200
300
400
500
500
600
700
0
100
200
300
600
8200
E
E
EXISTING CSM1LEE POND TO BE
RETAINED
W
W
W
W
MODIFIED OWAKABASIN
PROPOSED KERB AND CHANNEL
PROPOSED KERBAND CHANNEL
PROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
ON RAMP
OFF RAMP
POND OVERFLOW TOMONTGOMERIES DRAIN
HALSWELL JUNCTION ROAD
N
HALSWELL JUNCTION ROAD
JOIN
LINE
- SH
EET
14JO
IN LI
NE -
SHEE
T 12
JOIN LINE - SHEET 18JOIN LINE - SHEET 14
PROPOSEDDISPOSAL FIELD
EXISTING 1050mm Ø TWINCULVERTS
RAMP POND 1 (FIRSTFLUSH)
RAMP POND 2
EXISTING 750mm ØCULVERT
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 1:21 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C414.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C414
1
AW TP
NJD TM
CMG
10.05.12
1:2000
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
BACKFILL EXISTING RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
RETAIN EXISTING RACE
1800
1900
2000
2100
2200
100
200
300
400
500
0
100 200
300
W
W
W
W
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
W
N
JOIN LINE - SHEET 15JOIN LINE - SHEET 4
JOIN LINE - SHEET 5JOIN LINE - SHEET 15
HAMP
TONS
ROA
D
WATERHOLES ROADC
SM
2
CS
M2
WATERHOLES ROAD
This Drawing must not beused for Construction unlesssigned as Approved
Date
CheckDrafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:17 October 2012 - 2:16 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C415.dwgPlotted by: Annie Porteous
A3 Scale
FOR CONSENT
62236-B-C415 0
AW TP
NJD TM
CMG
10.05.12
1:2000
EXISTING BOUNDARY
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
RETAIN EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SIPHON STRUCTURE
LEGEND
W
BACKFILL EXISTING STOCKWATER RACE
INDICATIVE PROPOSED POND
SURFACE WATER SOAKAGE AREA
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
PROPOSED RISING MAIN
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
3300
3400
3500
3600
3700
0 100
200
300 500 600 700
C
C
C
C
C
C
C
C
C
C
C
C
CC
CC
CC
CC
CC
C
EE
EE
EE
EEEEEEEEEE
EE
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EXISTING SLUICE GATES TOCONTROL STOCKWATER RACEFLOWS
WW
WW
WW
WW
WW
WW
WW
WW
WW
WW
WW
WW
W
WW
WW
WW
WW
WW
WW
WW
WW
WW
WW
WW
WW
W
WW
WW
WW
WW
SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC
SW_SDC
SW_SDC
SW_SDC
SW_SDC
WW
WW
WW
WW W
W
WW
WW
WW
N
JOIN LINE - SHEET 6JOIN LINE - SHEET 16
JOIN LINE - SHEET 16JOIN LINE - SHEET 7
TRENTS ROADTRENTS ROAD
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:3 July 2013 - 4:15 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C416.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C416
1
AW TP
NJD TM
CMG
10.05.12
1:2000
SW_SDC
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
EXISTING STOCKWATER RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
SW_S
DCSW
_SDC
WW
WW
WW
WW
SW_S
DCSW
_SDCSHANDS ROAD
SHANDS ROAD
N
JOIN LINE - SHEET 10
JOIN LINE - SHEET 9
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
HVHV
HVHV
HVHV
HVHV
HVHV
HVHV
HVHV
HVHV
HVHV
HVHV
HVHV HV
HVHV
HVHV HV
HVHV
HVHV
HV HV HV HVHV
HVHV
HV HVHV
HVHV
HVHV HV
HVHV
HV HV HV HV HV HV HV
HVHV
HVHV
HV
HVHV
HVHV
HV
HVHV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
HV
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
EEEEE E
E
E
EE
EE
EE
E
EE
E
EE
E
EE
EE
EE
E E E E E E E E E E E EE E
EE
EEEEEEEEEEEEEEEE EEEE
EEE
EEEE
MARS
HS R
OAD
MARS
HS R
OAD
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 1:12 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C417.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C417
1
AW TP
NJD TM
CMG
10.05.12
1:2000
SANITARY SEWER (CCC & SDC)
CHORUS CABLE
SUPPLY WATER (CCC & SDC)
STORMWATER (CCC &SDC)
ABANDONED LINE
HIGH VOLTAGE O/H
TELSTRA CLEAR CABLE
TELECOM CABLE
TELECOM FIBRE OPTIC
ORION U/G POWER
LEGEND - EXISTING SERVICE
ENABLE NETWORK
CONTACT ENERGY / ROCKGAS
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
BACKFILL EXISTING RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
W
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
RETAIN EXISTING RACE
6900
7000
7100
7200
7300
7400
7500
7600
7700 7800 7900
8000
8100
0
100
200
0
100200
0
100
200
300
400
500
100
200
300
400
500
600
700
0100
200
0
100
200
300
400
500
600
300
0
100
200
300
400
500
600
8200
W
W
W
W
WW
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 2:41 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C425.dwg
Plotted by:
James Long
A3 Scale
FOR COMMENT
62236-B-C425
1
D. CROWLEY TP
TM TM
GAP
16.10.12
1:4000
AC426
AC426
BC426
BC426
JOHN PATERSON DR EXTENSION
HALSWELL JUNCTION ROAD
SPRI
NGS R
OAD
CSM2
MODIFIED MUSHROOM POND
MODIFIED OWAKA BASIN WITHGROUND WATER INFILTRATION
MAIZE MAZE FOREBAY(FIRST FLUSH)
RAMP POND 2
RESHAPED AND EXTENDED OWAKABASIN WITH ACCESS TRACK FORMAINTENANCE
N
MONTGOMERYS DRAIN TO BE RE-ALIGNED
MONTGOMERYS DRAINTO BE INFILLED
MAIZE MAZE POND 1
MAIZE MAZE POND 2
PROPOSED DISPOSALTRENCHES
MH 550
MH 600
MH 650
MH 500
GROUNDWATER OUTLET DRAINTO UPPER KNIGHTS STREAM(OFF PAGE)
UPPER KNIGHTS STREAM(AS PER THE NRRP PLANNINGMAPS - LOWLAND STREAM)
GROUNDWATERINFILTRATION GALLERY
EXISTING RACE TO BE INFILLED ANDREALIGNED TO NEW ACCESS ROAD
REALIGN STREAM ADJACENT TONEW ACCESS ROAD
GROUND WATER LOWERING TRUNKDRAINAGE (FINAL ALIGNMENT TBC)
EXISTING HALSWELL JUNCTION ROAD POND(OFF PAGE)
EXISTING MONTGOMERYS DRAIN
EXISTING HALSWELL JUNCTION ROADOVERFLOW PIPE TO MONTGOMERYS DRAIN(MODIFIED DURING CSM1 CONSTRUCTION)
PIPE TO CONNECT MONTGOMERYSDRAIN TO OWAKA
PROPOSED CYCLEWAY
REALIGN STOCKWATERRACE
RAMP POND OVERFLOW VIA EXISTINGMONTGOMERYS DRAIN PIPED SECTION
CCC PROPOSED OWAKASWALE TO WILMERS QUARRY
CONTROL WEIR TO DIRECTFIRST FLUSH TO OWAKA BASIN
OWAKA BASIN OVERFLOW VIAEXISTING MONTGOMERYS DRAINPIPED SECTION
EXISITNG SW PIPE DRAINING TOEXISTING STOCKWATER RACE
EXISITNG OWAKA CULVERT TOBE EXTENDED
RAMP POND 1 (FIRST FLUSH)
MONTGOMERYS DRAIN REPLACEDWITH SWALE
RELOCATE EXISTING INLET
OVERLAND FLOW BUND
WILMERS QUARRY
MAIZE MAZE POND OVERFLOW TOSWALE
MAIZE MAZE POND DRAW DOWNPIPE
EMERGENCY OVERFLOW FROMMUSHROOM POND
EXISTING BOUNDARY
INDICATIVE PROPOSED POND
PROPOSED STORMWATER PIPE
PROPOSED CROSS DRAIN
PROPOSED SWALE
PROPOSED CATCHPIT
BACKFILL EXISTING RACE
PROPOSED STOCKWATER RACE
PROPOSED SOAK PIT LOCATION
SURFACE WATER SOAKAGE AREA
SIPHON STRUCTURE
LEGEND
CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS
SOAKPIT WATER QUALITY DRY POND
GROUNDWATER MANAGEMENTDRAINAGE SYSTEM
RETAIN EXISTING RACE
PROPOSED CYCLEWAY
0
100
200
300
400
500CHAINAGE 600
10
20
30
600
700
800
839
10
20
30
200
300
400
500CHAINAGE 600
700
800
900
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateApprovedCheckedDrawnRevisionNo
Title
Project
Client
Check
Designed
Approved
Drawn
A1 Scale
Design
This drawing has been prepared for the benefit
of the NZ Transport Agency (NZTA). No
liability is accepted by these companies or any
employee or sub-consultant of these
companies with respect to its use by any other
person.
This disclaimer shall apply notwithstanding
that the drawing may be made available to
other persons for an application for permission
or approval or to fulfil a legal requirement.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Plot Date: Cad File No:12 April 2013 - 1:23 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C426.dwg
Plotted by:
James Long
A3 Scale
FOR CONSENT
62236-B-C426
1
DC TP
TM TM
GAP
16.10.12
V. 1:2000, V: 1:500
SECTIONAC425 SCALE 1 :1000 H, 1:250 V @ A1
SECTIONBC425 SCALE 1 :1000 H, 1:250 V @ A1 LEGEND
EXISTING LIDAR SURFACE
INTERIM SURFACE
FINAL SURFACE
DESIGN WATER LEVEL
SPRI
NGS
ROAD
JOHN
PAT
ERSO
N DR
EXTE
NSIO
N
CSM2
POND
2
MAIZE MAZE PONDS
POND
1
FORE
BAY
HALS
WEL
L JUN
CTIO
NRO
AD O
N-RA
MP
CSM2MU
SHRO
OMPO
ND 1
RAMP
PON
D
MODI
FIED
OWAK
ABA
SIN
RAMPMU
SHRO
OMPO
ND 2
MUSH
ROOM
POND
2
MUSH
ROOM
POND
3
POND DESIGN WATERLEVEL = 18.5m RL
POND DESIGN WATERLEVEL = 19.6m RL
EXISTING MUSHROOMPOND TO BE FILLED ASPART OF CSM2
POND DESIGN WATERLEVEL = 21.38m RL
POND DESIGN WATERLEVEL = 19.75m RL POND INVERT
LEVEL = 18.75m RLEXISTING FILL AND UNDERDRAINAGE SYSTEM
SPRI
NGS
ROAD
QUAR
RY
HALS
WEL
LJU
NCTI
ON R
OAD
MH 50
0
MH 55
0
MH 60
0
MH 60
0
MH 65
0
VERTICAL 1:250 @ A1HORIZONTAL 1:1000 @ A1
GROUND WATER LOWERING CONNECTIONNETWORK AND INFILTRATION TRENCH
GROUND WATER LOWERING TRUNKDRAINAGE TO UPPER KNIGHT STREAM
APPROXIMATE GROUND PROFILE
INFILTRATION TRENCH AND GROUNDWATER LOWERING TRUNK MAIN
UPPE
R KN
IGHT
S ST
REAM
SECTION ALONG OUTFALL PIPESECTION ALONG SECTION A
JOIN LINE 1
JOIN LINE 1
APPROXIMATE GROUND PROFILE
APPROXIMATE GROUND PROFILE