csm2 and msrfl project: drainage layout plansplot date: 11 april 2013 - 11:01 a.m. plotted by: james...

28
FOR CONSENT 62236-A-C401 0 AMW TP NJD TM CMG 10.05.12 1:2000 (A3) This Drawing must not be used for Construction unless signed as Approved Date Check Drafting Date Approved Checked Drawn Revision No Title Project Client Check Designed Approved Drawn A1 Scale Design This drawing has been prepared for the benefit of the NZ Transport Agency (NZTA). No liability is accepted by these companies or any employee or sub-consultant of these companies with respect to its use by any other person. This disclaimer shall apply notwithstanding that the drawing may be made available to other persons for an application for permission or approval or to fulfil a legal requirement. DO NOT SCALE Note: * indicates signatures on original issue of drawing or last revision of drawing Plot Date: Cad File No: 17 October 2012 - 12:56 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings A\400 Drainage\62236-A-C401.dwg Plotted by: Annie Porteous A3 Scale SW_SDC EXISTING BOUNDARY SOAKPIT OVERLAND FLOW PROPOSED STORMWATER PIPE PROPOSED CROSS DRAIN PROPOSED SWALE PROPOSED CATCHPIT EXISTING STOCKWATER RACE PROPOSED STOCKWATER RACE PROPOSED SOAK PIT LOCATION SIPHON STRUCTURE LEGEND W SANITARY SEWER (CCC & SDC) CHORUS CABLE SUPPLY WATER (CCC & SDC) STORMWATER (CCC &SDC) ABANDONED LINE HIGH VOLTAGE O/H TELSTRA CLEAR CABLE TELECOM CABLE TELECOM FIBRE OPTIC ORION U/G POWER LEGEND - EXISTING SERVICE ENABLE NETWORK CONTACT ENERGY / ROCKGAS

Upload: others

Post on 28-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

FOR CONSENT

62236-A-C401 0

AMW TP

NJD TM

CMG

10.05.12

1:2000 (A3)

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:17 October 2012 - 12:56 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings A\400 Drainage\62236-A-C401.dwgPlotted by: Annie Porteous

A3 Scale

SW_SDC

EXISTING BOUNDARY

SOAKPIT OVERLAND FLOW

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

LEGEND

W

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 2: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

FOR CONSENT

62236-A-C402

1

AMW TP

NJD TM

CMG

10.05.12

1:2000

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 9:04 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C402.dwg

Plotted by:

James Long

A3 Scale

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

W

BACKFILL EXISTING STOCKWATER RACE

SOAKPIT OVERLAND FLOW

INDICATIVE PROPOSED POND

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

LEGENDSANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 3: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

FOR CONSENT

62236-A-C403

1

AMW TP

NJD TM

CMG

10.05.12

1:2000

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 9:52 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C403.dwg

Plotted by:

James Long

A3 Scale

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

W

BACKFILL EXISTING STOCKWATER RACE

SOAKPIT OVERLAND FLOW

INDICATIVE PROPOSED POND

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

LEGEND

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 4: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

FOR CONSENT

62236-A-C404 0

AMW TP

NJD TM

CMG

10.05.12

1:2000

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:17 October 2012 - 1:00 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings A\400 Drainage\62236-A-C404.dwgPlotted by: Annie Porteous

A3 Scale

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

LEGEND

W

BACKFILL EXISTING STOCKWATER RACE

SOAKPIT OVERLAND FLOW

INDICATIVE PROPOSED POND

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

Page 5: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

FOR CONSENT

62236-A-C405 0

AMW TP

NJD TM

CMG

10.05.12

1:2000

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:17 October 2012 - 1:01 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings A\400 Drainage\62236-A-C405.dwgPlotted by: Annie Porteous

A3 Scale

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

LEGEND

W

BACKFILL EXISTING STOCKWATER RACE

SOAKPIT OVERLAND FLOW

INDICATIVE PROPOSED POND

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 6: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

FOR CONSENT

62236-A-C406 0

AMW TP

NJD TM

CMG

10.05.12

1:2000 (A3)

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:17 October 2012 - 1:03 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings A\400 Drainage\62236-A-C406.dwgPlotted by: Annie Porteous

A3 Scale

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

LEGEND

W

BACKFILL EXISTING STOCKWATER RACE

SOAKPIT OVERLAND FLOW

INDICATIVE PROPOSED POND

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 7: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

FOR CONSENT

62236-A-C408

1

DX TP

TM TM

GAP

16.10.12

1:2000

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:11 April 2013 - 11:01 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C408.dwg

Plotted by:

James Long

A3 Scale

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

W

BACKFILL EXISTING STOCKWATER RACE

SOAKPIT OVERLAND FLOW

INDICATIVE PROPOSED POND

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

LEGENDSANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 8: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

FOR CONSENT

62236-A-C411

1

DX TP

TM TM

GAP

16.10.12

1:5000

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 9:49 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C411.dwg

Plotted by:

James Long

A3 Scale

SW_SDC

SW_SDC

S

SW

HV HV

E

TELSTRA

TCOM TCOM

FO FO

C

EN EN

NG NG

Page 9: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

FOR CONSENT

62236-A-C412

2

JAL TP

JR DGA

GAP

21.05.13

1:5000

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

W

BACKFILL EXISTING STOCKWATER RACE

SOAKPIT OVERLAND FLOW

INDICATIVE PROPOSED POND

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:21 May 2013 - 2:19 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-A-C412.dwg

Plotted by:

James Long

A3 Scale

LEGENDLEGEND

Page 10: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

CC

CC

CC

CC

CC

CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC

CC

C

TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA

0 100 200 300 400 500 600

0

100

200

300

1100

1200

130014

00

0

100

200

0

0

WW

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

APPROXIMATE EXTENT OF 'NATURAL'1m GROUNDWATER CLEARANCE

APPROXIMATE EXTENT OF'NATURAL' 1m GROUNDWATERCLEARANCE

SUBSOIL DISPOSAL/GROUNDWATERDRAINAGE AREAROBINSONS OVERPASS RISING

MAIN TO DISPOSAL FIELD

ROBINSONS ROAD OVERPASSGROUNDWATER PUMPING WETWELL

STOCKWATER RACEUPSTREAM SIPHON

STRUCTURE

STOCKWATER RACE PIPEDADJACENT TO ROBINSONSROAD CUTTING

PROPOSED BUFFERSTORAGE DISPOSAL FIELD

APPROXIMATE EXTENT OF OVERLANDFLOW PROTECTION STORMWATER BUND TO CONTAIN

POTENTIALLY CONTAMINATED SITERUNOFF

STOCKWATER RACE PIPEDADJACENT TO CURRAGHSROAD CUTTING

EXISTING STOCKWATERRACE TO BE REMOVED

APPROXIMATE EXTENT OF OVERLANDFLOW PROTECTION

ROBI

NSON

S RO

AD

EXTENT OF WORKS - CSM2EXTENT OF WORKS - MSRFL

JOIN LINE - SHEET 1

JOIN LINE - SHEET 2

CURR

AGHS

ROA

D

ROBINSONS ROADOVERPASS

POTENTIALLY CONTAMINATED LAND.EXCAVATION TO BE MINIMISED IN THIS AREA

SUMP AND SOAKPIT FORMOUNTABLE KERB ANDCHANNEL DRAINAGE

N

LARGE PIPE (CONVEYANCEOF STORM FLOWS)

STOCKWATER RACE SIPHON(CONVEYANCE OF LOWFLOWS)

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 10:00 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C401.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C401

1

AW TP

NJD TM

CMG

10.05.12

1:2000

SW_SDC

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 11: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

600

700

800

900

1000 1100

1200

1300

1400

600

700

800

900

1000

1100

0

100

200

300

400

500

600

500

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE

STOCKWATER RACEUPSTREAM SIPHONSTRUCTURE

RECONTOUR SURFACEAS REQUIRED

PROPOSED CROSS DRAINTO SAFE GUARD AGAINSTOVERLAND FLOW FLOODING

EXISTING 750mmØ RC RAILWAY CULVERT(APPROXIMATE LOCATION)

OVERLAND FLOW UPSTREAM SIPHONSTRUCTURE SIPHON ENTRY. APPROX200mm BELOW OUTSIDE LANE LINELEVEL OF CARRIAGEWAY

SCRUFFYDOMEMANHOLE

PROPOSED STORMWATERBUND

JOIN LINE - SHEET 1JOIN LINE - SHEET 2

JOIN LINE - SHEET 2

JOIN LINE - SHEET 4

MAINTENANCEACCESS

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:11 April 2013 - 9:46 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C402.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C402

1

AW TP

NJD TM

CMG

10.05.12

1:2000

Page 12: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

E EE E

EE

E EE E E E

EE

EE

EE

EE

EE

E

EE

EE

EE

EE

EE

EE

EE

E

EE

EE EE EE EE EE EE EE EE EE EE EE EE E

E

E E

E

E

E

TRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA TELSTRA

1100

600

700

40 0

500

0100

0

0

100

600

70 0

800

0100200

300

400

500

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_ SDC

JOIN LINE - SHEET 2

JOIN LINE - SHEET 3

N

JONES ROAD

C S M 2

WATERHOLES ROAD

DAWSONS ROAD

JONES ROAD

M A I N S O U T H R O A D ( S H 1 )

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:17 October 2012 - 1:33 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C403.dwgPlotted by: Annie Porteous

A3 Scale

FOR CONSENT

62236-B-C403 0

AW TP

NJD TM

CMG

10.05.12

1:2000

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

LEGEND

W

BACKFILL EXISTING STOCKWATER RACE

INDICATIVE PROPOSED POND

SURFACE WATER SOAKAGE AREA

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

PROPOSED RISING MAIN

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 13: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

1300

1400

1500

1600

1700

1800

1900

2000

0

100

200

300

400

200

300

WATERHOLES ROAD

J OIN L INE - SHEET 2J OIN L INE - SHEET 4

N

JOIN

LINE

- SH

EET

15

JOIN

LINE

- SH

EET

4

JOIN

LINE

- SHE

ET 5

JOIN

LINE

- SHE

ET 4

WATERHOLES ROAD

C S M 2

WATER

HOLES ROAD

E

E

E

E

E

E

E

E

E

E

E

E

E

EE

EE

EE

EE

E

EE

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EE

E

E

E

E

E

E

EE

E E

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE

STOCKWATER RACEDOWNSTREAM SIPHONSTRUCTURE

PROPOSED STORMWATERBUND

PROPOSED KERBAND CHANNEL

W

W

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

W

PROPOSED CROSS DRAIN TO SAFEGUARD AGAINST OVERLAND FLOWFLOODING

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

PROPOSED STORMWATERBUND

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

WATERHOLES ROADUNDERPASS

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:17 October 2012 - 1:34 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C404.dwgPlotted by: Annie Porteous

A3 Scale

FOR CONSENT

62236-B-C404 0

AW TP

NJD TM

GARY PAYNE

29.08.12

1:2000

EXISTING BOUNDARY

INDICATIVEPROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED DRY SWALE

PROPOSED SWALE

PROPOSED FLUME

PROPOSED CATCHPIT

PROPOSED DRAIN

PROPOSED STOCKWATER RACE

PROPOSED HEADWALL

INDICATIVE AREAS OFENVIRONMENTAL SIGNIFICANCE

PROPOSED SOAK PIT LOCATION

LEGEND

W

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 14: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

E

E

E

E

E

E

E

E

2100

2200 2300

2400

2500

2600

2700

2800

500

HAMPTONS ROAD

WATERHOLES ROAD

N

JOIN

LINE

- SH

EET

5

JOIN

LINE

- SH

EET

4

JOIN LI

NE - SH

EET 5

JOIN LI

NE - SH

EET 1

5

JOIN

LINE

- SH

EET

6JO

IN LI

NE -

SHEE

T 5

W

W

W

W

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

PROPOSED STORMWATERCROSS DRAIN

PROPOSED STORMWATERBUND

PROPOSED STORMWATERBUND

WATERHOLES ROAD

STORMWATER RACE TO BEREALIGNED

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 11:43 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C405.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C405

1

AW TP

NJD TM

CMG

10.05.12

1:2000

SW_SDC

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 15: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

CC

CC

CC

CC

CC

CC

CC

CC

CC

CC

C

CC

CC

CC

C

C

C

C

CCCCCCCCCCC

EXISTING STOCKWATER RACETO BE INFILLED

NEW STOCKWATER RACE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

PROPOSED STORMWATERBUND

PROPOSED KERB AND CHANNEL

EXISTING STOCKWATERRACE TO BE INFILLED

EXISTING STOCKWATER RACETO BE INFILLED

PROPOSED CROSS DRAIN TOSAFE GUARD AGAINSTOVERLAND FLOW FLOODING

STOCKWATER RACE TOTERMINATE

2800

2900

3000

3100

3200

3300

3400

3500

200

300

500

600

WW

WW

W

W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W

WW

WW

W

W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W

WWWWWWWWWWWW

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDCSW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

WW

WW

WW

W

W

W

WW

WW

W

N

JOIN

LINE

- SH

EET

6

JOIN

LINE

- SH

EET

5

JOIN

LINE

- SH

EET

7JO

IN LI

NE -

SHEE

T 6

TRENTS ROAD

TRENTS ROAD

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:3 July 2013 - 4:13 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C406.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C406

2

AW TP

NJD TM

CMG

10.05.12

1:2000

SW_SDC

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 16: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

3500

3600

3700

3800

3900 4000 4100

4200

300

500

C

C

C

C

C

C

C

C

C

C

C

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

STOCKWATER RACE UPSTREAMSIPHON STRUCTURE

STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE

REALIGN EXISTINGSTOCKWATER RACE

REALIGN EXISTINGSTOCKWATER RACE

PROPOSED STORMWATERBUND

BLAKES ROAD TERMINATES

PROPOSED STORMWATERBUND

PROPOSED STORMWATERBUND

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

OVERLAND FLOW UPSTREAMSIPHON STRUCTURETRENTS ROAD UNDERPASS

BLAKES ROAD TERMINATES

BLAKES ROAD

WW

SW_SDC

SW_SDC

SW_SDC

SW_S

DC SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDCSW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

WW

WW

WW

W

W

W

W

W

W

W SW_SDC

N

JOIN

LINE

- SH

EET

7JO

IN LI

NE -

SHEE

T 6

JOIN

LINE

- SH

EET

8

JOIN

LINE

- SH

EET

7

JOIN LINE - SHEET 16JOIN LINE - SHEET 7

TRENTS ROAD

TRENTS ROAD

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:3 July 2013 - 4:14 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C407.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C407

2

AW TP

NJD TM

CMG

10.05.12

1:2000

SW_SDC

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 17: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

4200

43 00

4 4 00

4500

4600 4700 4800

4900

0 100

0

100

200

300

NJO

IN LI

NE -

SHEE

T 8

JOIN

LINE

- SH

EET

7

J OIN

L INE

- SH

EET 9

J OIN

L INE

- SH

EET 8

C S M 2

SW_S

DC

SW_S

DC

SW_S

DC

SW_S

DC

SW_S

DC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

PROPOSED STORMWATERBUND

PROPOSED CROSS DRAIN TOSAFE GUARD AGAINSTOVERLAND FLOW FLOODING

PROPOSED STORMWATERBUND

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:17 October 2012 - 1:43 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C408.dwgPlotted by: Annie Porteous

A3 Scale

FOR CONSENT

62236-B-C408 0

AW TP

NJD TM

CMG

10.05.12

1:2000

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

LEGEND

W

BACKFILL EXISTING STOCKWATER RACE

INDICATIVE PROPOSED POND

SURFACE WATER SOAKAGE AREA

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

PROPOSED RISING MAIN

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 18: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

4900

5000

5100

5200

5300

5400

5500

5600

100

200

300

400

500

600

0

100

200

0

100

200

300

300

400

500

600

0

100

0

100

0

100

200

300

400

500

300

400

500

600

700

SHAN

DS R

OAD

N

JOIN

LINE

- SH

EET

9JO

IN LI

NE -

SHEE

T 8

JOIN

LINE

- SH

EET

10JO

IN LI

NE -

SHEE

T 9

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

HVHV

HVHV

HVHV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

E

E

E

E

E

E

E

E

E

E

E

EE

E

E

E

E

E

E

E

E

EE

EE

EE

EE

E

E

E

E E

EE

E

E

E

E

EE

SW_SDCSW_SDC

WW

WW

W

WW

SW_SDCSW_SDC

SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT

SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT

SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT

PROPOSED KERB AND CHANNEL

REALIGN LAND DRAINAGEWATER RACE

STOCKWATER RACETO BE INFILLED

SURFACE WATER SOAKAGEAREA DISPOSAL LEVELS TOBE LOWER THAN ADJACENTSWALE INVERT

SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT

RECONTOUR SURFACE AS REQUIRED

RECONTOUR SURFACE AS REQUIRED

RECONTOUR SURFACE AS REQUIRED

RECONTOUR SURFACE AS REQUIRED

RECONTOUR SURFACE AS REQUIRED

PROPOSED STORMWATERBUND WITH NIB WALL IFREQUIRED

PROPOSED KERB AND CHANNEL

PROPOSED CROSS DRAIN

PROPOSED KERB AND CHANNEL

PROPOSED CROSS DRAIN TOSAFE GUARD AGAINSTOVERLAND FLOW FLOODING

SHANDS ROAD UNDERPASS

NOTE: LOCATION OF OVERLAND FLOWPATHS TO BE CONFIRMEDBASED ON DETAILED SURVEY. ADDITIONAL SIPHONS MAY BEREQUIRED TO TRANSMIT OVERLAND FLOW UPSTREAM OFMOTORWAY UNDER THE OFF RAMP TO SOAKAGE

STOCKWATER RACE UPSTREAMSIPHON STRUCTURE

STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE

STOCKWATER RACE CHANGES TOLAND DRAINAGE RACEDOWNSTREAM OF SHANDS ROAD

MARSHS ROAD

SWALE TO DISPOSAL AREA

SWALE TO DISPOSAL AREA

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 12:52 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C409.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C409

1

AW TP

NJD TM

CMG

10.05.12

1:2000

SW_SDC

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 19: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

5600 5700 5800

5900

6000

6100

6200

6300

300

400100

200

300

400

500

600

700

800

400

500

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

CC

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

WW W W W W W

W

W

W

W

SURFACE WATER SOAKAGE AREADISPOSAL LEVELS TO BE LOWERTHAN ADJACENT SWALE INVERT

PROPOSED KERB AND CHANNEL

LAND DRAINAGE RACE UPSTREAMSIPHON STRUCTURE

EXISTING STOCKWATERRACE TO BE INFILLED

EXISTING STOCKWATER RACE(LAND DRAINAGE RACE)

PROPOSED STORMWATER BUND

EXISTING STOCKWATER RACETO BE INFILLED

MARSHS ROAD UNDERPASS

MARSHS ROAD

N

JOIN

LINE

- SH

EET

10

JOIN

LINE

- SH

EET

9

JOIN

LINE

- SH

EET

11JO

IN LI

NE -

SHEE

T 10

REALIGN STOCKWATER RACE(LAND DRAINAGE RACE)

LAND DRAINAGE RACE DOWNSTREAMSIPHON STRUCTURE

REALIGN STOCKWATER RACE(LAND DRAINAGE RACE)

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 9:13 a.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C410.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C410

1

AW TP

NJD TM

CMG

10.05.12

1:2000

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

BACKFILL EXISTING RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

RETAIN EXISTING RACE

Page 20: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

6300

6400 6500

6600

6700

6800

6900

7000

600

N

SPRINGS R

OAD

JOIN

LINE

- SH

EET

11

JOIN

LINE

- SH

EET

10

JOIN

LINE

- SH

EET

12

JOIN

LINE

- SH

EET

11

S

S

S

S

S

PROPOSED STORMWATERBUND OVERLAND FLOW UPSTREAM

SIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

PROPOSED STORMWATER BUND

OVERLAND FLOW UPSTREAMSIPHON STRUCTURE

PROPOSED STORMWATERBUND

CYCLE /WALKING TRAIL

OVERLAND FLOW DOWNSTREAMSIPHON STRUCTURE

PROPSOED CYCLEWAY

PROPSOED CYCLEWAY

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 12:59 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C411.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C411

1

AW TP

NJD TM

CMG

10.05.12

1:2000

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

BACKFILL EXISTING RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

RETAIN EXISTING RACE

Page 21: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

7000

7100

7200

7300

7400

7500

7600

7700

7800

0

100

200

100

200

300

400

500

100

200

300

400

500

600

W

W

W

W

W

WWW

WW

WW

WW

W

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

E

E

E

E

EE

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EEPROPOSED LAND DRAINAGE RACE

PROPOSED LAND DRAINAGE RACE

EXISTING FIELD DRAIN TO BE INFILLEDPROPOSED STORMWATER

TREATMENT AND DISPOSAL AREA

PROPOSEDDISPOSAL FIELD

PROPOSED CROSS DRAIN

PROPOSED KERB AND CHANNEL

REALIGN MONTGOMERIES DRAIN

STOCKWATER RACE UPSTREAMSIPHON STRUCTURE

STOCKWATER RACE DOWNSTREAMSIPHON STRUCTURE

EXISTING CSM1MUSHROOM PONDS

PROPOSED CROSS DRAIN

PROPOSED STORMWATER BUND

LOW LEVEL SLUICE VALVE AND MANHOLE, OUTLETPIPE TO MEET STORMWATER INFRASTRUCTURE ATCCC OWAKA BASIN OUTLET PIPE DISCHARGE POINT

SPRINGS ROAD UNDERPASS

ON RAMP

HALSWELL JUNCTION ROAD

SPRI

NGS R

OAD

JOHN PATERSON DRIVE

N

JOIN

LINE

- SH

EET

12JO

IN LI

NE -

SHEE

T 11

JOIN

LINE

- SH

EET

14JO

IN LI

NE -

SHEE

T 12

JOIN LINE - SHEET 12JOIN LINE - SHEET 13

-C425

PROPOSED CYCLEWAY

PROPOSED CYCLEWAY

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 1:01 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C412.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C412

1

AW TP

NJD TM

CMG

10.05.12

1:2000

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

BACKFILL EXISTING RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

RETAIN EXISTING RACE

Page 22: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

CC

CC

CC

CC

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

S

S

SS

SS

S

S

S

S

EXISTING CCC HALSWELLJUNCTION ROAD POND

EXISTING CSM1 DRAINAGE TOBE RETAINED IN THIS AREA

0

100

200

0

100

SPRIN

GS ROA

D

HALSWELL JUNCTION ROAD

N

JOIN LINE - SHEET 12JOIN LINE - SHEET 13

SPRI

NGS

ROAD

WILMERS ROAD

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:17 October 2012 - 2:12 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C413.dwgPlotted by: Annie Porteous

A3 Scale

FOR CONSENT

62236-B-C413 0

AW TP

NJD TM

CMG

10.05.12

1:2000

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

LEGEND

W

BACKFILL EXISTING STOCKWATER RACE

INDICATIVE PROPOSED POND

SURFACE WATER SOAKAGE AREA

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

PROPOSED RISING MAIN

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 23: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

7800

7900 8000 8100

8300 8400

8500

0 100200

200

300

400

500

500

600

700

0

100

200

300

600

8200

E

E

EXISTING CSM1LEE POND TO BE

RETAINED

W

W

W

W

MODIFIED OWAKABASIN

PROPOSED KERB AND CHANNEL

PROPOSED KERBAND CHANNEL

PROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

ON RAMP

OFF RAMP

POND OVERFLOW TOMONTGOMERIES DRAIN

HALSWELL JUNCTION ROAD

N

HALSWELL JUNCTION ROAD

JOIN

LINE

- SH

EET

14JO

IN LI

NE -

SHEE

T 12

JOIN LINE - SHEET 18JOIN LINE - SHEET 14

PROPOSEDDISPOSAL FIELD

EXISTING 1050mm Ø TWINCULVERTS

RAMP POND 1 (FIRSTFLUSH)

RAMP POND 2

EXISTING 750mm ØCULVERT

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 1:21 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C414.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C414

1

AW TP

NJD TM

CMG

10.05.12

1:2000

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

BACKFILL EXISTING RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

RETAIN EXISTING RACE

Page 24: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

1800

1900

2000

2100

2200

100

200

300

400

500

0

100 200

300

W

W

W

W

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

W

N

JOIN LINE - SHEET 15JOIN LINE - SHEET 4

JOIN LINE - SHEET 5JOIN LINE - SHEET 15

HAMP

TONS

ROA

D

WATERHOLES ROADC

SM

2

CS

M2

WATERHOLES ROAD

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

DesignThis drawing has been prepared for the benefitof the NZ Transport Agency (NZTA). Noliability is accepted by these companies or anyemployee or sub-consultant of thesecompanies with respect to its use by any otherperson.This disclaimer shall apply notwithstandingthat the drawing may be made available toother persons for an application for permissionor approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:17 October 2012 - 2:16 PM N:\NZ\Christchurch\Projects\51\28982 CSM2\CADD\CSM 2+3\CAD\Drawings - Scheme Assessment\Drawings B\400 Drainage\62236-B-C415.dwgPlotted by: Annie Porteous

A3 Scale

FOR CONSENT

62236-B-C415 0

AW TP

NJD TM

CMG

10.05.12

1:2000

EXISTING BOUNDARY

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

RETAIN EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SIPHON STRUCTURE

LEGEND

W

BACKFILL EXISTING STOCKWATER RACE

INDICATIVE PROPOSED POND

SURFACE WATER SOAKAGE AREA

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

PROPOSED RISING MAIN

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 25: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

3300

3400

3500

3600

3700

0 100

200

300 500 600 700

C

C

C

C

C

C

C

C

C

C

C

C

CC

CC

CC

CC

CC

C

EE

EE

EE

EEEEEEEEEE

EE

EE

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EXISTING SLUICE GATES TOCONTROL STOCKWATER RACEFLOWS

WW

WW

WW

WW

WW

WW

WW

WW

WW

WW

WW

WW

W

WW

WW

WW

WW

WW

WW

WW

WW

WW

WW

WW

WW

W

WW

WW

WW

WW

SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC SW_SDC

SW_SDC

SW_SDC

SW_SDC

SW_SDC

WW

WW

WW

WW W

W

WW

WW

WW

N

JOIN LINE - SHEET 6JOIN LINE - SHEET 16

JOIN LINE - SHEET 16JOIN LINE - SHEET 7

TRENTS ROADTRENTS ROAD

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:3 July 2013 - 4:15 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C416.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C416

1

AW TP

NJD TM

CMG

10.05.12

1:2000

SW_SDC

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

EXISTING STOCKWATER RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

Page 26: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

SW_S

DCSW

_SDC

WW

WW

WW

WW

SW_S

DCSW

_SDCSHANDS ROAD

SHANDS ROAD

N

JOIN LINE - SHEET 10

JOIN LINE - SHEET 9

CC

CC

CC

CC

CC

CC

CC

CC

CC

CC

HVHV

HVHV

HVHV

HVHV

HVHV

HVHV

HVHV

HVHV

HVHV

HVHV

HVHV HV

HVHV

HVHV HV

HVHV

HVHV

HV HV HV HVHV

HVHV

HV HVHV

HVHV

HVHV HV

HVHV

HV HV HV HV HV HV HV

HVHV

HVHV

HV

HVHV

HVHV

HV

HVHV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

HV

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

EEEEE E

E

E

EE

EE

EE

E

EE

E

EE

E

EE

EE

EE

E E E E E E E E E E E EE E

EE

EEEEEEEEEEEEEEEE EEEE

EEE

EEEE

MARS

HS R

OAD

MARS

HS R

OAD

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 1:12 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C417.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C417

1

AW TP

NJD TM

CMG

10.05.12

1:2000

SANITARY SEWER (CCC & SDC)

CHORUS CABLE

SUPPLY WATER (CCC & SDC)

STORMWATER (CCC &SDC)

ABANDONED LINE

HIGH VOLTAGE O/H

TELSTRA CLEAR CABLE

TELECOM CABLE

TELECOM FIBRE OPTIC

ORION U/G POWER

LEGEND - EXISTING SERVICE

ENABLE NETWORK

CONTACT ENERGY / ROCKGAS

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

BACKFILL EXISTING RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

W

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

RETAIN EXISTING RACE

Page 27: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

6900

7000

7100

7200

7300

7400

7500

7600

7700 7800 7900

8000

8100

0

100

200

0

100200

0

100

200

300

400

500

100

200

300

400

500

600

700

0100

200

0

100

200

300

400

500

600

300

0

100

200

300

400

500

600

8200

W

W

W

W

WW

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 2:41 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C425.dwg

Plotted by:

James Long

A3 Scale

FOR COMMENT

62236-B-C425

1

D. CROWLEY TP

TM TM

GAP

16.10.12

1:4000

AC426

AC426

BC426

BC426

JOHN PATERSON DR EXTENSION

HALSWELL JUNCTION ROAD

SPRI

NGS R

OAD

CSM2

MODIFIED MUSHROOM POND

MODIFIED OWAKA BASIN WITHGROUND WATER INFILTRATION

MAIZE MAZE FOREBAY(FIRST FLUSH)

RAMP POND 2

RESHAPED AND EXTENDED OWAKABASIN WITH ACCESS TRACK FORMAINTENANCE

N

MONTGOMERYS DRAIN TO BE RE-ALIGNED

MONTGOMERYS DRAINTO BE INFILLED

MAIZE MAZE POND 1

MAIZE MAZE POND 2

PROPOSED DISPOSALTRENCHES

MH 550

MH 600

MH 650

MH 500

GROUNDWATER OUTLET DRAINTO UPPER KNIGHTS STREAM(OFF PAGE)

UPPER KNIGHTS STREAM(AS PER THE NRRP PLANNINGMAPS - LOWLAND STREAM)

GROUNDWATERINFILTRATION GALLERY

EXISTING RACE TO BE INFILLED ANDREALIGNED TO NEW ACCESS ROAD

REALIGN STREAM ADJACENT TONEW ACCESS ROAD

GROUND WATER LOWERING TRUNKDRAINAGE (FINAL ALIGNMENT TBC)

EXISTING HALSWELL JUNCTION ROAD POND(OFF PAGE)

EXISTING MONTGOMERYS DRAIN

EXISTING HALSWELL JUNCTION ROADOVERFLOW PIPE TO MONTGOMERYS DRAIN(MODIFIED DURING CSM1 CONSTRUCTION)

PIPE TO CONNECT MONTGOMERYSDRAIN TO OWAKA

PROPOSED CYCLEWAY

REALIGN STOCKWATERRACE

RAMP POND OVERFLOW VIA EXISTINGMONTGOMERYS DRAIN PIPED SECTION

CCC PROPOSED OWAKASWALE TO WILMERS QUARRY

CONTROL WEIR TO DIRECTFIRST FLUSH TO OWAKA BASIN

OWAKA BASIN OVERFLOW VIAEXISTING MONTGOMERYS DRAINPIPED SECTION

EXISITNG SW PIPE DRAINING TOEXISTING STOCKWATER RACE

EXISITNG OWAKA CULVERT TOBE EXTENDED

RAMP POND 1 (FIRST FLUSH)

MONTGOMERYS DRAIN REPLACEDWITH SWALE

RELOCATE EXISTING INLET

OVERLAND FLOW BUND

WILMERS QUARRY

MAIZE MAZE POND OVERFLOW TOSWALE

MAIZE MAZE POND DRAW DOWNPIPE

EMERGENCY OVERFLOW FROMMUSHROOM POND

EXISTING BOUNDARY

INDICATIVE PROPOSED POND

PROPOSED STORMWATER PIPE

PROPOSED CROSS DRAIN

PROPOSED SWALE

PROPOSED CATCHPIT

BACKFILL EXISTING RACE

PROPOSED STOCKWATER RACE

PROPOSED SOAK PIT LOCATION

SURFACE WATER SOAKAGE AREA

SIPHON STRUCTURE

LEGEND

CONTRIBUTING AREA TOPROPOSED STORMWATERTREATMENT AND DISPOSAL AREAS

SOAKPIT WATER QUALITY DRY POND

GROUNDWATER MANAGEMENTDRAINAGE SYSTEM

RETAIN EXISTING RACE

PROPOSED CYCLEWAY

Page 28: CSM2 and MSRFL Project: Drainage layout plansPlot Date: 11 April 2013 - 11:01 a.m. Plotted by: James Long Cad File No: \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400

0

100

200

300

400

500CHAINAGE 600

10

20

30

600

700

800

839

10

20

30

200

300

400

500CHAINAGE 600

700

800

900

This Drawing must not be

used for Construction unless

signed as Approved

Date

Check

Drafting

DateApprovedCheckedDrawnRevisionNo

Title

Project

Client

Check

Designed

Approved

Drawn

A1 Scale

Design

This drawing has been prepared for the benefit

of the NZ Transport Agency (NZTA). No

liability is accepted by these companies or any

employee or sub-consultant of these

companies with respect to its use by any other

person.

This disclaimer shall apply notwithstanding

that the drawing may be made available to

other persons for an application for permission

or approval or to fulfil a legal requirement.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Plot Date: Cad File No:12 April 2013 - 1:23 p.m. \\Beca.net\projects\339\3390691\CAD\Drawings_PostSubmission\Drawings\400 Drainage\62236-B-C426.dwg

Plotted by:

James Long

A3 Scale

FOR CONSENT

62236-B-C426

1

DC TP

TM TM

GAP

16.10.12

V. 1:2000, V: 1:500

SECTIONAC425 SCALE 1 :1000 H, 1:250 V @ A1

SECTIONBC425 SCALE 1 :1000 H, 1:250 V @ A1 LEGEND

EXISTING LIDAR SURFACE

INTERIM SURFACE

FINAL SURFACE

DESIGN WATER LEVEL

SPRI

NGS

ROAD

JOHN

PAT

ERSO

N DR

EXTE

NSIO

N

CSM2

POND

2

MAIZE MAZE PONDS

POND

1

FORE

BAY

HALS

WEL

L JUN

CTIO

NRO

AD O

N-RA

MP

CSM2MU

SHRO

OMPO

ND 1

RAMP

PON

D

MODI

FIED

OWAK

ABA

SIN

RAMPMU

SHRO

OMPO

ND 2

MUSH

ROOM

POND

2

MUSH

ROOM

POND

3

POND DESIGN WATERLEVEL = 18.5m RL

POND DESIGN WATERLEVEL = 19.6m RL

EXISTING MUSHROOMPOND TO BE FILLED ASPART OF CSM2

POND DESIGN WATERLEVEL = 21.38m RL

POND DESIGN WATERLEVEL = 19.75m RL POND INVERT

LEVEL = 18.75m RLEXISTING FILL AND UNDERDRAINAGE SYSTEM

SPRI

NGS

ROAD

QUAR

RY

HALS

WEL

LJU

NCTI

ON R

OAD

MH 50

0

MH 55

0

MH 60

0

MH 60

0

MH 65

0

VERTICAL 1:250 @ A1HORIZONTAL 1:1000 @ A1

GROUND WATER LOWERING CONNECTIONNETWORK AND INFILTRATION TRENCH

GROUND WATER LOWERING TRUNKDRAINAGE TO UPPER KNIGHT STREAM

APPROXIMATE GROUND PROFILE

INFILTRATION TRENCH AND GROUNDWATER LOWERING TRUNK MAIN

UPPE

R KN

IGHT

S ST

REAM

SECTION ALONG OUTFALL PIPESECTION ALONG SECTION A

JOIN LINE 1

JOIN LINE 1

APPROXIMATE GROUND PROFILE

APPROXIMATE GROUND PROFILE