current status of xmass experiment 11 th international workshop on low temperature detectors...

Download Current status of XMASS experiment 11 th International Workshop on Low Temperature Detectors (LTD-11) Takeda Hall, University of Tokyo, JAPAN 8/1, 2005

If you can't read please download the document

Upload: aileen-lucas

Post on 18-Jan-2018

216 views

Category:

Documents


0 download

DESCRIPTION

100kg Prototype 800kg detector 10 ton detector ~ 30cm ~ 80cm ~ 2.5m R&D Dark matter search Multipurpose detector (solar neutrino,  …) We are now here  Strategy of the scale-up With light guide

TRANSCRIPT

Current status of XMASS experiment 11 th International Workshop on Low Temperature Detectors (LTD-11) Takeda Hall, University of Tokyo, JAPAN 8/1, 2005 Hiroshi Ogawa (ICRR) Whats XMASS Xenon MASSive detector for solar neutrino (pp/ 7 Be) Xenon neutrino MASS detector ( decay) Xenon detector for Weakly Interacting MASSive Particles (DM search) Multi purpose low-background experiment with liq. Xe Large Z (=54) Self-shielding effect Large photon yield (~42 photons/keV ~ NaI(Tl)) Low threshold High density (~3 g/cm 3 ) Compact detector (10 ton: sphere with diameter of ~2m) Purification (distillation) No long life radioactive isotope Scintillation wavelength ~175 nm, detected directly by PMT Relative high temperature (~165 K) Merit of using Liq. Xe: 100kg Prototype 800kg detector 10 ton detector 30cm 80cm 2.5m R&D Dark matter search Multipurpose detector (solar neutrino, ) We are now here Strategy of the scale-up With light guide Gamma ray shield OFHC cubic chamber Liq. Xe (31cm) 3 MgF 2 window 54 2-inch low BG PMTs 16% photo- coverage Hamamatsu R8778 100 kg prototype detector In the Kamioka Mine (near the Super-K) 2,700 m.w.e Vertex and energy reconstruction by fitter Vertex and energy calibration using radioactive sources 137Cs & 60Co Self shielding power are measured by 137Cs &60Co Confirmation of estimated 800 kg detector performance PMT are developed for VUV region (Q.E.~ PMT performance (Gain, Q.E.) in low temp. is similar to one in room temp. z position distribution of the collimated ray source run Data and MC agree well Demonstration of self shielding effect Shelf shielding for real data and MC Good agreement (< factor 2) Self shielding effect can be seen clearly. Very low background (10 -2 keV) REAL DATA MC simulation All volume 20cm FV 10cm FV (3kg) All volume 20cm FV 10cm FV (3kg) Miss-reconstruction due to dead-angle region from PMTs. Reduced in Light guide measurement & future 800kg detector. Event rate (/kg/day/keV) /kg/day/keV Aug. 04 run preliminary 3.9days livetime ~1.6Hz, 4 fold, triggered by ~0.4p.e. Kr = 3.31.1 ppt (by mass spectrometer) 687keV (99.563%) as BG Achieved by distillation U-chain = (337)x g/g (by prototype detector) Th-chain < 23x g/g(90%CL) (by prototype detector) 1/2 =164 s (Q=3.3MeV) (7.7MeV) 214 Bi 214 Po 210 Pb 1/2 =299ns (Q=2.3MeV) (8.8MeV) 212 Bi 212 Po 208 Po Delayed coincidence search (radiation equilibrium assumed) Internal backgrounds in liq. Xe were measured Main sources in liq. Xe are Kr, U-chain and Th-chain XMASS succeeds to reduce Kr concentration in Xe from ~3[ppb] to 3.3(1.1)[ppt] with one cycle (~1/1000) ~3m Lower Higher ~1% ~99% Purified Xe: 3.31.1 ppt Kr (measured) Off gas Xe: 330100 ppb Kr (measured) Raw Xe: ~3 ppb Kr (preliminary) (178K) (180K) Processing speed : 0.6 kg / hour Design factor : 1/1000 Kr / 1 pass Purified Xe : Off gas = 99:1 Xe purification system Boiling point atm) Xe178.1K Kr129.4K 800 kg detector Main purpose: Dark Matter search ~800-2 PMTs immersed into liq. Xe 70% photo-coverage ~80cm diameter ~5 keVee threshold External ray BG: 60cm, 346kg 40cm, 100kg Expected dark matter signal (assuming cm 2, Q.F.=0.2 50GeV / 100GeV,) pp & 7 Be solar Achieved Expected sensitivity SI ~ cm 2 = 10-9 pb SD~ cm 2 = 10-3 pb XMASS FV 0.5 ton year E th = 5 keVee~25 p.e., 3 discovery w/o any pulse shape info. Detector design Geometry : 12 pentagons / pentakisdodecahedron A tentative design (not final one) Hamamatsu R8778MOD(hex) 12cm 5.4cm 5.8cm (edge to edge) 0.3cm (rim) Hexagonal quartz window Effective area: 50mm (min) QE