customer: 901-simb simba ground - wicksteed · 2021. 1. 6. · solid steel to bs 970 part 1 steel...

29
Complied by Date ISSUE ECN DATE SIGN CUSTOMER: FIXING: ORDER No: AB 01/05/12 901-SIMB Simba Ground 0 1655 01/05/12 AB 1 Minor 30/10/13 DB

Upload: others

Post on 01-Apr-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Complied by

Date

ISSUEECNDATESIGN

CUSTOMER: FIXING:ORDER No:

AB

01/05/12

901-SIMB Simba Ground

01655

01/05/12AB

1

Minor30/10/13

DB

Page 2: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Complied by

Date

ISSUEECNDATESIGN

CUSTOMER: FIXING:ORDER No:

AB

01/05/12

901-SIMB Simba Ground

750 1150 1250

750850

750

375

15

01

850

375

750

600 x 300

700 x 300

650 x 400

All foundations are 300 x 300unless otherwise stated

All foundations are 375 deepunless otherwise stated

01655

02/05/12AB

1

Minor30/10/13

DB

Page 3: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Complied by

Date

ISSUEECNDATESIGN

CUSTOMER: FIXING:ORDER No:

AB

02/05/12

901-SIMB Simba Ground

3700 2450

2420

2330

6250

6150

10

50

18

00

800

2600

18004350

R2450

R2500

R1000

R1000

R1700R1500

Safety surfacing29.5m² of 40mm wetpourwith 20.5m edging

01655

02/05/12AB

1

Minor30/10/13

DB

Page 4: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Complied by

Date

ISSUEECNDATESIGN

CUSTOMER: FIXING:ORDER No:

AB

02/05/12

901-SIMB Simba Ground

450

6500

400

6500

01655

02/05/12AB

Safety surfacing34.5m² of 33mm tileswith 24.5m edging

1

Minor30/10/13

DB

Page 5: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Complied by

Date

ISSUEECNDATESIGN

CUSTOMER: FIXING:ORDER No:

AB

02/05/12

901-SIMB Simba Ground

1125

125

900

6500

7000

Safety surfacing26 grassmats (1m x 1.5m)

01655

02/05/12AB

1

Minor30/10/13

DB

Page 6: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Complied by

Date

ISSUEECNDATESIGN

CUSTOMER: FIXING:ORDER No:

AB

02/05/12

901-SIMB Simba Loose-fill

2475

1450 3500 1300

145

04000

900

2375

1300

1400

180

085

0100

0

900 2550 1000 1800

6250

6350

01655

02/05/12AB

Safety surfacing32m² of loose-fill areawith 21.5m edging

1

Minor

30/10/13

DB

Page 7: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Complied by

Date

ISSUEECNDATESIGN

CUSTOMER: FIXING:ORDER No:

AB

02/05/12

901-SIMB Simba Ground

01655

02/05/12AB

90167Access steps

90159Low slide

90157Corner monkey pole slider

90155Curved wall

90154Curved climbing wall

90152Open tower

90151Quadrant tower

90110Double arch bridge

1

Minor30/10/13

DB

Page 8: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

SPECIFICATION Bridge: Made from 250 and 20 mm Nominal bore tube to BS 1387. Floor Panel: Made from Durbar 3 mm thick Chequer plate Logs: Made from recycled plastic. Fasteners: Non standard anti-vandal, plated for weather protection. Finish: Low lead polyester powder paint to BSEN 71 Part 3

INSTALLATION INSTRUCTIONS 1 Read installation instructions through before commencing erection of unit. 2 Do NOT tighten fastenings until the unit is completely assembled

DELIVERY LIST

Part No. Description Qty

90110-01 Double Arch Bridge Assembly 1

- Fixings pack 1

TROPICA DOUBLE ARCH BRIDGE

PROD CODE: 90110

SIZE: 1446 x 785 x 1100 mm

AGE RANGE: UP TO 8 YEARS

WEIGHT OF HEAVIEST PART 25 Kg

OVERALL WEIGHT OF UNIT 93 Kg

TROPICA - Double Arch Bridge 90110 page 1 of 3

Fixing Detail to Tower: 1. Attach Double Arch Bridge To Tower

using M10 x 50 lg Pent button head screws (B).

Page 9: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

TROPICA - Oriental roof 90123 page 2 of 3

TROPICA - Double Arch Bridge 90110 page 2 of 3

MINIMUM SPACE

FOUNDATION DETAIL:

Fixing Detail 1. Logs are attached to chequer plate floor,

using (E) M10 x 25 lg Pent button head screw, Neoprene Washer (F) and (D) M10 Safety fastener.

FIXING DETAIL FOR LOGS

Page 10: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

REF QTY DESCRIPTION PART No

A 1 Double Arch Bridge Assembly 90110-01

B 8 M10 x 50 lg Pent button head screw 2176-129

C 7 Plastic log 90110-02

D 21 M10 Safety Fastener 2177-002

E 21 M10 x 25 lg Pent button head screw 2176-126

F 21 Neoprene Washer 2900-041

COMPILED: APPROVED : REV NEW 1 2 3

MH ECN 1396 1455 minor minor

DATE: DATE: SIG. MH SB PK SB

31/010/01 DATE. 31/10/01 23/09/03 18/03/04 18/05/05

Note:-All spare parts are available from Wicksteed Leisure on request.

For maintenance instructions see separate sheet.

TROPICA - Double Arch Bridge 90110 page 3 of 3

Note:-Ensure all installation aids are removed before first use.

Page 11: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

SPECIFICATION

INSTALLATION INSTRUCTIONS

Note

Note

PROD. CODE

SIZE

AGE RANGE

F/ FALL HEIGHT

HEAVIEST PART

TOTAL WEIGHT

Planet Jungle

Single Towers90150/90151/90152

0.8 x 0.8 x 3.25

990mm

Approx 70 - 78 kg ea

90150/1/2Page 1 of 3

90150SquareTower

90151QuadrantTower

90152OpenTower

Solid steel to BS 970 part 1Steel RHS to BS 4848 part 23mm Durbar chequer plateWelds are from copper-free wire to BS EN 440Low lead polyester powder paint to BS 71 part 3

1 Read instructions thoroughly before commencing installation of unit

2 Excavate foundations as shown in the foundation plan

3 Position tower in the excavated foundations on a brick, ensuring it is plumb,square and at the correct height, orientation and distance

4 When unit is fully assembled and all fixings secure, back fill the foundationswith concrete (4 parts gravel/2 parts sand/1 part cement) 0.095m² for towerswith 3 legs, 0.125m² for towers with 4 legs

5 Allow concrete to set for 48 hours before first use

ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE

Page 12: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

90150/1/2

Page 2 of 3

1295

deck

heig

ht

220

8

3248

324

8

2898324

8

2898

90150SquareTower

90151QuadrantTower

90152OpenTower

800800

800

800

Page 13: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

REV

ECN

SIG.

DATE:

COMPILED

DATE:

90150/1/2

Page 3 of 3

AB

23/04/12

3 LEG TOWER - FOR BARK FIX ADD

DESCRIPTIONPART NUMBERQTYITEM

BELOW GROUND ASSY5071-00331

SPRAGGING IRON3031-01032

M12 x 25 LG HEX HD SCREW2175-13463

4 LEG TOWER - FOR BARK FIX ADD

DESCRIPTIONPART NUMBERQTYITEM

BELOW GROUND ASSY5071-00341

SPRAGGING IRON3031-01042

M12 x 25 LG HEX HD SCREW2175-13483

FoundationsCare must be taken in abnormal conditions

750

750

750

750

300 square

300 square

380

Brick

400

305

38

0

Round offconcrete

Bark

Brick

123

Typical foundation detailsfor all single towers

01655AB

23/04/12

990

de

ckheig

ht

1

Minor

DB

30/10/13

Page 14: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

SPECIFICATION

INSTALLATION INSTRUCTIONS

Note

Note

PROD. CODE

SIZE

AGE RANGE

F/ FALL HEIGHT

HEAVIEST PART

TOTAL WEIGHT

Planet JungleCurved Climbing Wall

90154

1.09 x 0.24 x 1.89

6 to Adult

1.01m

Approx 22.5 kg

Approx 23.5 kg

90154Page 1 of 2

15mm thick HDPE 100% recyclableStandard fixings are made to either BS 3692 or BS 4190Non-standard fixings are anti-vandal and corrosion resistant

1 Read instructions thoroughly before commencing installation of unit

The climbing wall is overbent

2 To fit the panel position it against the tower and gently push in the centre,easing the panel over the struts and uprights as necessary

3 Fit the fixings down the middle of the panel

4 Fit the fixings down both sides

ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE

Page 15: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

A ( 1 : 5 )

REV

ECN

SIG.

DATE:

COMPILED

DATE:

90154

Page 2 of 2

AB

24/04/12

PARTS LIST

DESCRIPTIONPART NUMBERQTYITEM

CURVED CLIMBING PANEL90154-0111

FIXING WASHER2900-041162

Black Poepplemann Cup2611-031_Cup323

Black Poepplemann Cap2611-031_Cap324

FIXING SPACER (15 panel)2472-009165

Wicksteed Washer2215-519166

M10 Binx Nut2191-010167

M10 x 50 Hex Head Bolt2185-038168

A

6 3 7 4

5

24 8 3

1

These fixings to goagainst inside oftower strut

01655AB

24/04/12

11672AB

03/12/12

Page 16: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

SPECIFICATION

INSTALLATION INSTRUCTIONS

Note

Note

PROD. CODE

SIZE

AGE RANGE

F/ FALL HEIGHT

HEAVIEST PART

TOTAL WEIGHT

Planet Jungle

Curved Wall90155

1.09 x 0.24 x0.99

0.99m

Approx 14 kg

Approx 14.5 kg

90155Page 1 of 2

15mm thick HDPE 100% recyclableStandard fixings are made to either BS 3692 or BS 4190Non-standard fixings are anti-vandal and corrosion resistant

1 Read instructions thoroughly before commencing installation of unit

The climbing wall is overbent

2 To fit the panel position it against the tower and gently push in the centre,easing the panel over the struts and uprights as necessary

3 Fit the fixings down the middle of the panel

4 Fit the fixings down both sides

ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE

Page 17: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

A ( 1 : 5 )

REV

ECN

SIG.

DATE:

COMPILED

DATE:

90155

Page 2 of 2

AB

24/04/12

PARTS LIST

DESCRIPTIONPART NUMBERQTYITEM

CURVED WALL PANEL90155-0111

FIXING WASHER2900-041102

Black Poepplemann Cup2611-031_Cup203

Black Poepplemann Cap2611-031_Cap204

FIXING SPACER (15 panel)2472-009105

Wicksteed Washer2215-519106

M10 Binx Nut2191-010107

M10 x 50 Hex Head Bolt2185-038108

A

6 3 7 4

5

2

3

8

4

1

These fixings to goagainst inside oftower strut

01655AB

24/04/12

11672AB

03/12/12

Page 18: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

SPECIFICATION

INSTALLATION INSTRUCTIONS

Note

Note

PROD. CODE

SIZE

AGE RANGE

F/ FALL HEIGHT

HEAVIEST PART

TOTAL WEIGHT

Planet JungleCorner Monkey Pole

90157

0.8 x 0.55 x 2.54

Up to 8 years old

990mm

Approx 25.9 kg

Approx 26.2 kg

90157Page 1 of 3

Solid steel to BS 970 part 1Steel nominal bore tube (medium) to BS 1387Welds are from copper-free wire to BS EN 440Low lead polyester powder paint to BS 71 part 3

Standard fixings are made toBS 3692 or BS 4190Non-standard fixings are anti-vandaland corrosion resistant

1 Read instructions thoroughly before commencing installation of unit

2 Excavate foundations as shown in the plan

3 Position pole slider on a brick in the excavated hole, ensuring it is plumb, squareand at the correct height

4 Fix the pole slider to the tower as shown

5 When the unit is fully assembled and all fixings secure, backfill the foundationwith 0.03m³ of concrete (4 parts gravel/2 parts sand/1 part cement)

6 Allow concrete to set for 48 hours before first use

ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE

Page 19: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

90157

Page 2 of 3

FoundationsCare must be taken in abnormal conditions

850

850

750

750

300 square

37

5

(379)

Brick

40

0

300

380

Brick

BarkRound offconcrete

Page 20: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

REV

ECN

SIG.

DATE:

COMPILED

DATE:

90157

Page 3 of 3

AB

24/04/12

FOR BARK FIX ADD

DESCRIPTIONPART NUMBERQTYITEM

BELOW GROUND ASSY5071-00314

SPRAGGING IRON3031-01015

M12 x 25 LG HEX HD SCREW2175-13426

PARTS LIST

DESCRIPTIONPART NUMBERQTYITEM

WELDED CORNER MONKEY POLE ASSY90157-0111

Wicksteed Washer2215-51942

M10 x 25 Pent Button Head2176-12643

Sliding Pole Assy4202-48217

M10 x 40 Pent Button Head2176-13318

M10 Safety Fastener2177-00219

2

3

1

Fixingsintotower

01655AB

24/04/12

8

9

7

1

Minor

DB

21/08/15

Page 21: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

SPECIFICATION

INSTALLATION INSTRUCTIONS

Note

Note

PROD. CODE

SIZE

AGE RANGE

F/ FALL HEIGHT

HEAVIEST PART

TOTAL WEIGHT

PLanet Jungle

Low Slide90159

0.8 x 2.66 x 1.9

Up to 8 years old

1.19m

Approx 57.5 kg

Approx 85.5 kg

90159Page 1 of 3

Solid steel to BS 970 part 1Steel nominal bore tube (medium) to BS 1387Stainless steel to BS 1449 part 2Welds are from copper-free wire to BS EN 440Low lead polyester powder paint to BS 71 part 3

Standard fixings are made toBS 3692 or BS 4190Non-standard fixings are anti-vandaland corrosion resistant

1 Read instructions thoroughly before commencing installation of unit

2 Excavate foundations as shown in the plan

3 Place lower end on bricks in the excavated hole

4 Position slide and slideguard against the tower, ensuring it is plumb, squareand at the correct height

5 Fit the support legs, placing them on bricks in their excavated hole

6 When the unit is fully assembled and all fixings secure, backfill the foundationwith 0.03m³ of concrete (4 parts gravel/2 parts sand/1 part cement)

7 Allow concrete to set for 48 hours before first use

ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE

In accordance with 6.1.3 EN1176-1:2008 we recommend that slides do notface south or near due south due to heat build up.

Page 22: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

90159

Page 2 of 3

FoundationsCare must be taken in abnormal conditions

375

375

1150 1250

600

300700

300

Bricks

Page 23: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

REV

ECN

SIG.

DATE:

COMPILED

DATE:

90159

Page 3 of 3

AB

24/04/12

DESCRIPTIONPART NUMBERQTYITEM

LOW SLIDE CHUTE90159-0111

SINGLE SLIDE BARRIER90106-0212

SPRAGGING IRON3031-01023

SUPPORT LEG3001-03124

Top Cap Plug2611-00225

Wicksteed Washer2215-51946

M12 Plain Washer2215-50947

M10 Washer2215-50828

M12 Spring Washer2212-20429

M10 Safety Fastener2177-002210

M12 x 30 Pent Button Head2176-177211

M10 x 30 Pent Button Head2176-132212

M10 x 50 Pent Button Head2176-129213

M10 x 25 Pent Button Head2176-126214

14 6

12 6

25

11 9 73

4

1

01655AB

24/04/12

1

Minor

DB

11/03/14

13 8

107

Tower uprights must be drilled thro'on site to accept fixings

18/08/15

Minor

MC

2

Page 24: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

SPECIFICATION

INSTALLATION INSTRUCTIONS

Note

Note

PROD. CODE

SIZE

AGE RANGE

F/ FALL HEIGHT

HEAVIEST PART

TOTAL WEIGHT

Planet Jungle

Access Steps90167

0.48 x 0.8 x 2.3

4 years to adult

990mm

Approx 48.8 kg

Approx 50 kg

90167Page 1 of 3

Solid steel components to BS 970 part 1Nominal bore tube (medium) to BS 1387RHS to BS 4848 part 23mm Durbar chequer plateStandard fixings to BS 3692 or BS 4190

Non-standard fixings are anti-vandaland corrosion resistantWelds are from copper-free wire to BS EN 440Low lead polyester powder paint to BS 71

1 Read instruction thoroughly before commencing installation of unit

2 Excavate foundations as shown in the plan

3 Position steps on bricks in the excavated foundations and secure to toweras shown

4 When the unit is fully assembled and all fixings secure, backfill the foundationswith 0.09m³ of concrete (4 parts gravel/2 parts sand/1 part cement)

5 Allow concrete to set for 48 hours before first use

ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE

Page 25: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

90167

Page 2 of 3

FoundationsCare must be taken in abnormal conditions

750

65

0400

375

Brick

400

300

375

Brick

Round offconcrete

Bark

456

Page 26: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

REV

ECN

SIG.

DATE:

COMPILED

DATE:

90167

Page 3 of 3

AB

25/04/12

FOR BARK FIX ADD

DESCRIPTIONPART NUMBERQTYITEM

Z-SHAPED BELOW GROUND FIXING5071-02824

M10 Nut2193-00625

M10 x 30 LG HEX HD SCREW2175-11626

PARTS LIST

DESCRIPTIONPART NUMBERQTYITEM

ACCESS STEPS WELDED ASSY90167-0111

Wicksteed Washer2215-51942

M10 x 25 Pent Button Head2176-12643

3

21

01655AB

25/04/12

Page 27: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Product: Date of Issue: 30/04/12

Issue:

Item Unit Qty Part No. Checked

1 7 90110-02

2 1 90110-01

3 1 90151-01

4 1 90152-01

5 1 90154-01

6 1 90155-01

7 1 90157-01

8 1 4202-482

9 1 90159-01

10 1 Single slide barrier 90106-02

11 2 Support leg 3001-031

12 1 Access steps welded assembly 90167-01

1 Fixing pack

Picked By: Checked By:

COMPILED REV 0 1

BY: AB ECN No. 1655 Minor

DATE 30/04/2012 24/08/2015

DATE: 30/04/12 SIGN AB DB

Order No:

Plastic log *

Welded quadrant tower assembly

Sliding Pole Assy

Items marked * to be fitted prior to despatch

Low slide chute

Sheet 1 of 1

Welded corner monkey pole assembly

DESPATCH LIST

Welded open tower assembly

Curved climbing panel *

Curved wall panel *

Double arch bridge welded assembly

Description

901-SIMB Simba

Total No. of Items

Page 28: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Product: Date of Issue: 30/04/12

Issue:

Item Unit Qty Part No. Checked

1 21 2900-041

2 21 2177-002

3 8 2176-129

4 21 2176-126

5 16 2900-041

6 32 2611-031

7 32 2611-031

8 16 2472-009

9 16 2215-519

10 16 2191-010

11 16 2185-038

12 10 2900-041

13 20 2611-031

14 20 2611-031

15 10 2472-009

16 10 2215-519

17 10 2191-010

18 10 2185-038

Picked By: Checked By:

COMPILED REV 0 1 2 3 4 5

BY: AB ECN No. 1655 1672 Minor Minor Minor Minor

DATE 30/04/2012 03/12/2012 23/09/2013 30/10/2013 12/03/2014 24/08/2015

DATE: 30/04/12 SIGN AB AB MC DB DB DB

Total No. of Items

M10 binx nut *

M10 x 50 hex head bolt *

Items marked * to be fitted before despatch

Wicksteed washer *

Wicksteed washer *

901-SIMB Simba

Fixing washer *

Fixing spacer (15 panel) *

M10 x 50 hex head bolt *

M10 binx nut *

Black Poepplemann cap *

Sheet 1 of 2

Fixing spacer (15 panel) *

Fixing washer *

FIXINGS LIST

M10 x 25 pent button head screw *

M10 x 50 pent button head screw

Black Poepplemann cup *

Black Poepplemann cap *

Order No:

Black Poepplemann cup *

90110 Double Arch Bridge

90154 Curved Climbing Wall

M10 safety fastener *

Description

90155 Curved Wall

Fixing washer *

Page 29: CUSTOMER: 901-SIMB Simba Ground - Wicksteed · 2021. 1. 6. · Solid steel to BS 970 part 1 Steel RHS to BS 4848 part 2 3mm Durbar chequer plate Welds are from copper-free wire to

Product: Date of Issue: 30/04/12

Issue:

Item Unit Qty Part No. Checked

19 4 2215-519

20 4 2176-126

21 1 2176-133

22 1 2177-002

23 2 3031-010

24 2 Top cap plug 2611-002

25 6 Wicksteed washer 2215-519

26 2 M12 washer 2215-509

27 2 M12 spring washer 2212-204

28 2 M12 x 30 pent button head screw 2176-177

29 2 M10 x 30 pent button head screw 2176-132

30 2 M10 x 25 pent button head screw 2176-126

31 2 M10 x 50 Pent Button Head 2176-129

32 2 M10 Safety Fastener 2177-002

33 2 M10 Washer 2215-508

34 4 Wicksteed washer 2215-519

35 4 M10 x 25 pent button head screw 2176-126

36 16 Insert plug M10 2611-016

37 2 M10/M12 pent key 2372-008

Picked By: Checked By:

COMPILED REV 0 1 2 3 4 5

BY: AB ECN No. 1655 1672 Minor Minor Minor Minor

DATE 30/04/2012 03/12/2012 23/09/2013 30/10/2013 12/03/2014 24/08/2015

DATE: 30/04/12 SIGN AB AB MC DB DB DB

90159 Low Slide

Spragging iron

Items marked * to be fitted before despatch

Total No. of Items

90167 Access Steps

90157 Corner Monkey Pole Slider

Wicksteed washer

M10 x 25 pent button head screw

M10 x 40mm Pent Button Head

M10 Safety Fastener

FIXINGS LIST Sheet 2 of 2

901-SIMB Simba

Order No:

Description