Ød adhesive lined p platinum resistance thermometer ... sensors...heat shrink sleeve l1 Ød l1 l2...

4
PPL1-P Planum Resistance Thermometer with Flying Lead Sensor Probe with Flying Lead. General Purpose Industrial and OEM Applicaons. Ideal for use with Compression Fings or Pockets. Standard Choice of Wiring, Detectors, Sheath Sizes & Lead Types. Manufacture to Your Requirements. UKAS or Traceable Calibraon Available. Specifications Sensor Type Platinum Resistance Thermometer—Pt100 or Pt1000. Other types available—please enquire. Operating Range Generally limited to range of lead as standard - see below - but can be extended by request. Sheath Material 316 stainless steel Tolerance Band Class B, Class A, 1/3 DIN, 1/5 DIN or 1/10 DIN Wiring System 2, 3 or 4 wire, Simplex or Duplex Lead Types A - PVC/PVC Screened (-10 to +105°C) B - Silicone Rubber Unscreened (-60 to +180°C) C - PTFE/PTFE Screened (-200 to +250°C) D - Glass Fibre Stainless Steel Overbraid (0 to 350°C) (Other cables available upon request). ØD ADHESIVE LINED HEAT SHRINK SLEEVE L1 ØD L1 L2 50 L2 50 PLAIN POT SEAL PLUS ADHESIVE LINED HEAT SHRINK SLEEVE Thermelec Ltd., Old Naas Road, Bluebell, Dublin 12 Phone (01) 4568111 Fax: (01) 4568108 E-mail: [email protected] Web: www.thermelec.ie

Upload: others

Post on 16-Jun-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ØD ADHESIVE LINED P Platinum Resistance Thermometer ... Sensors...HEAT SHRINK SLEEVE L1 ØD L1 L2 50 L2 50 PLAIN POT SEAL PLUS ADHESIVE LINED HEAT SHRINK SLEEVE Thermelec Ltd., Old

PPL1-P Platinum Resistance Thermometer with Flying Lead

Sensor Probe with Flying Lead. General Purpose Industrial and OEM

Applications. Ideal for use with Compression Fittings or

Pockets. Standard Choice of Wiring, Detectors, Sheath

Sizes & Lead Types. Manufacture to Your Requirements. UKAS or Traceable Calibration Available.

Specifications

Sensor Type Platinum Resistance Thermometer—Pt100 or Pt1000. Other types available—please enquire.

Operating Range Generally limited to range of lead as standard - see below - but can be extended by request.

Sheath Material 316 stainless steel

Tolerance Band Class B, Class A, 1/3 DIN, 1/5 DIN or 1/10 DIN

Wiring System 2, 3 or 4 wire, Simplex or Duplex

Lead Types A - PVC/PVC Screened (-10 to +105°C) B - Silicone Rubber Unscreened (-60 to +180°C) C - PTFE/PTFE Screened (-200 to +250°C) D - Glass Fibre Stainless Steel Overbraid (0 to 350°C) (Other cables available upon request).

Ø DA DHE S IV E LINED

HE AT SHRINK SLE E VE

L1

Ø D

L1 L2 50

L2 50

P LAIN P OT S E AL P LUS

A DHE S IV E LINED

HE AT SHRINK SLE E VE

Thermelec Ltd., Old Naas Road, Bluebell, Dublin 12 Phone (01) 4568111 • Fax: (01) 4568108 • E-mail: [email protected] • Web: www.thermelec.ie

Page 2: ØD ADHESIVE LINED P Platinum Resistance Thermometer ... Sensors...HEAT SHRINK SLEEVE L1 ØD L1 L2 50 L2 50 PLAIN POT SEAL PLUS ADHESIVE LINED HEAT SHRINK SLEEVE Thermelec Ltd., Old

PPL1-T Thermocouple Probe with Flying Lead

Sensor Probe with Flying Lead. General Purpose Industrial and OEM

Applications. Ideal for use with Compression Fittings or

Pockets. Standard Choice of Thermocouple Types,

Sheath Sizes & Lead Types. Manufacture to Your Requirements. UKAS or Traceable Calibration Available.

Specifications

Sensor Type Type J, K or T thermocouple. Insulated or Grounded hot

junction.

Operating Range Limited to range of lead as standard— see below—can be

extended at additional cost

Sheath Material 316 stainless steel

Tolerance Band BS EN 60584-2:1993 Class 1 or Class 2 (Determined by ma-

terial availability)

Wiring System Simplex or Duplex

Lead Types A—PVC/PVC Screened (-10 to +105°C)

B—PTFE/PTFE Screened (-200 to +250°C) C—Glass Fibre Stainless Steel Overbraid (0 to 350°C) (Other cables available upon request).

Ø DA DHE S IV E LINED

HE AT SHRINK SLE E VE

L1

Ø D

L1 L2 50

L2 50

P LAIN P OT S E AL P LUS

A DHE S IV E LINED

HE AT SHRINK SLE E VE

Thermelec Ltd., Old Naas Road, Bluebell, Dublin 12 Phone (01) 4568111 • Fax: (01) 4568108 • E-mail: [email protected] • Web: www.thermelec.ie

Page 3: ØD ADHESIVE LINED P Platinum Resistance Thermometer ... Sensors...HEAT SHRINK SLEEVE L1 ØD L1 L2 50 L2 50 PLAIN POT SEAL PLUS ADHESIVE LINED HEAT SHRINK SLEEVE Thermelec Ltd., Old

PPL2-P Resistance Thermometer with Fixed Process Connection & Lead

Sensor Probe with Flying Lead and ProcessConnection.

Welded Process Connection for EasyInstallation.

No Need for Compression Fittings. Standard Choice of Wiring, Detectors, Sheath

Sizes & Lead Types. Manufactured to Your Requirements. UKAS or Traceable Calibration Available.

Specifications

Sensor Type Platinum Resistance Thermometer—Pt100 or Pt1000. Other types available—please enquire.

Operating Range Generally limited to range of lead as standard - see below - but can be extended by request.

Sheath Material 316 stainless steel

Tolerance Band Class B, Class A, 1/3 DIN, 1/5 DIN or 1/10 DIN

Wiring System 2, 3 or 4 wire, Simplex or Duplex

Lead Types A - PVC/PVC Screened (-10 to +105°C) B - Silicone Rubber Unscreened (-60 to +180°C) C - PTFE/PTFE Screened (-200 to +250°C) D - Glass Fibre Stainless Steel Overbraid (0 to 350°C) (Other cables available upon request).

50L1

ØDTHREAD T

L2

ADHESIVE LINED

HEAT SHRINK SLEEVE

Thermelec Ltd., Old Naas Road, Bluebell, Dublin 12 Phone (01) 4568111 • Fax: (01) 4568108 • E-mail: [email protected] • Web: www.thermelec.ie

Page 4: ØD ADHESIVE LINED P Platinum Resistance Thermometer ... Sensors...HEAT SHRINK SLEEVE L1 ØD L1 L2 50 L2 50 PLAIN POT SEAL PLUS ADHESIVE LINED HEAT SHRINK SLEEVE Thermelec Ltd., Old

PPL2-T Thermocouple with Fixed Process Connection and Lead

Sensor Probe with Flying Lead and ProcessConnection.

Welded Process Connection for EasyInstallation.

No Need for Compression Fittings. Standard Choice of Wiring, Detectors, Sheath

Sizes & Lead Types. Manufactured to Your Requirements. UKAS or Traceable Calibration Available.

Specifications

Sensor Type Type J, K or T thermocouple. Insulated or Grounded hot

junction.

Operating Range Limited to range of lead as standard— see below—can be

extended at additional cost

Sheath Material 316 stainless steel

Tolerance Band BS EN 60584-2:1993 Class 1 or Class 2 (Determined by ma-

terial availability)

Wiring System Simplex or Duplex

Lead Types A—PVC/PVC Screened (-10 to +105°C)

B—PTFE/PTFE Screened (-200 to +250°C) C—Glass Fibre Stainless Steel Overbraid (0 to 350°C) Other cables available upon request).

50L1

ØDTHRE A D T

L2

A DHE S IV E LINED

HE AT SHRINK SLE E V E

Thermelec Ltd., Old Naas Road, Bluebell, Dublin 12 Phone (01) 4568111 • Fax: (01) 4568108 • E-mail: [email protected] • Web: www.thermelec.ie