d-max wall - huntsman building solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of...

38
870 Curé Boivin, Boisbriand, Quebec, Canada J7G 2A7 Tel: 450.437.0123 866.437.0223 www.huntsmanbuildingsolutions.com A business unit of Huntsman Corporation 16.10.2020 D-Max Wall Advantages compared to exterior insulation - Can be sprayed regardless of temperature or wind (up to -20°C) - No scaffolding or vessel necessary. Less machinery therefore less rental cost, logistics and risk of accident. - Building insulation can be performed as the walls go up. - Less materials therefore time and costs savings for execution. - Important heating cost savings in winter. - Avoids exterior compartimentalization (NBC Article 3.1.11.2.). - CAN/ULC S101 tested assembly for high rise buildings (>3 storeys) (UL EW25). - Sequencing of work simpler and easier to manage for the superintendent since there are less workers to execute each step. - Avoids overspray. - Avoids having to install an interior furring in comparison with a wool insulated cavity where the electricity cannot run through the stud cavity. Assembly : - Lightweight or brick siding - Omega bars or brick ties - Exterior sheating with taped joints (Densglass Gold, Securock, Glasroc) - Heatlok Soya R-6/inch (variable thickness) - Z girts (variable thickness) - Steel stud 6’’ or 3 5/8’’ - Interior gyprock

Upload: others

Post on 06-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

870 Curé Boivin, Boisbriand, Quebec, Canada J7G 2A7 Tel: 450.437.0123 866.437.0223

www.huntsmanbuildingsolutions.com

A business unit of Huntsman Corporation

16.10.2020

D-Max Wall

Advantages compared to exterior insulation

- Can be sprayed regardless of temperature or wind (up to -20°C) - No scaffolding or vessel necessary. Less machinery therefore less rental cost, logistics

and risk of accident. - Building insulation can be performed as the walls go up. - Less materials therefore time and costs savings for execution. - Important heating cost savings in winter. - Avoids exterior compartimentalization (NBC Article 3.1.11.2.). - CAN/ULC S101 tested assembly for high rise buildings (>3 storeys) (UL EW25). - Sequencing of work simpler and easier to manage for the superintendent since there are

less workers to execute each step. - Avoids overspray. - Avoids having to install an interior furring in comparison with a wool insulated cavity

where the electricity cannot run through the stud cavity. Assembly :

- Lightweight or brick siding - Omega bars or brick ties - Exterior sheating with taped joints (Densglass Gold, Securock, Glasroc) - Heatlok Soya R-6/inch (variable thickness) - Z girts (variable thickness) - Steel stud 6’’ or 3 5/8’’ - Interior gyprock

Page 2: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

870 Curé Boivin, Boisbriand, Quebec, Canada J7G 2A7 Tel: 450.437.0123 866.437.0223

www.huntsmanbuildingsolutions.com

A business unit of Huntsman Corporation

List of completed projects

Project Architect General Contractor

Saint Philippe Bilodeau Baril Lemming Dinamo

K Building Alpha Architecture Dalcon

Nicolas Beaudet Faille Normand Dinamo

List of upcoming projects

Project Architect General Contractor

Circa Condo ABCP Architecture Magil

Château Bellevue Saint-Nicolas CCM2 Architects Construction M. Grégore

Lienard PA Marquis Architect GM Development

800 Charest PA Marquis Architect GM Development

Saphir CCM2 Architects PMA Architects Constrobourg

Le Guillaume Beaudet Faille Normand Dinamo

Le Renaissance Architech Design Dinamo

Page 3: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

 

    

Nicolas Project 

    

         K Building Project                   Saint‐Philippe Project    

Page 4: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

 

 

Page 5: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

     

     

Page 6: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

RAISE THE SELF-ADHESIVE MEMBRANE 75mm (3'')

ON THE JAMB

THE FLEXIBLE FLASHING ABOVE OPENINGS

MUST EXCEED 200mm (8'') MIN. ON BOTH SIDES

OF THE OPENING

AIR-BARRIER/VAPOR-BARRIER MEMBRANE

STEEL STUD @ 400mm (16'') C/C

MASONRY LINTEL

Z BAR WITH EXTERIOR LEG POINTING DOWNWARD

G 20 MIN., MAX SPACING 610mm

RIGID BOARD INSULATION INSERTED IN THE

FOUNDATION, 600mm BELOW GROUND LEVEL

ONE COMPONENT PORTABLE POLYURETHANE FOAM

CAULKING WITH BACKER ROD AT PERIMETER

INTERMEDIARY EXTERIOR PANEL

HEATLOK SOYA HFO

MAX. 12mm (½'') JOINT BETWEEN PANELS

FLEXIBLE FLASHING

MEMBRANES MUST BE INSTALLED ACCORDING

TO MANUFACTURERS' REQUIREMENTS

NOTES: A FULL SURFACE MEMBRANE CAN BE

USED DEPENDING ON THE DESIGNER'S CHOICE

(NON ILLUSTRATED)

D-MAX WALL

LEGEND

1) THE ADVANTAGE OF THIS WALL SECTION IS A MAXIMUM EFFECTIVE R VALUE IN A VERY THIN WALL. THIS

INCREASES THE INHABITABLE FLOOR SPACE. THE STUD CAN BE A 92 MM OR A 152 MM DEPENDING ON THE

DESIGNER'S CHOICE.

2) THIS WALL SECTION ALLOWS TO APPLY ALL THE INSULATION FROM THE INTERIOR, SHELTERED FROM

THE WEATHER AND WITHOUT SCAFFOLDING.

3) THE OUTER Z BAR'S THICKNESS IS VARIABLE FROM 25 TO 125 MM ACCORDING TO THE DESIRED

EFFECTIVE R VALUE AND DESIGN CHOICES.

4) A MINIMUM THICKNESS OF 38MM IS RECOMMENDED TO COVER THE OUTER Z BAR FROM INSIDE TO CUT

THE THERMAL BRIDGE.

5) WHEN THE INTERIOR AIR SPACE IS MORE THAN 25 MM, ARTICLE 3.1.11.2 APPLIES.

6) DEMILEC IS AVAILABLE FOR REVIEWING PROJECT DETAILS, FOR A COORDINATION MEETING AT THE

BEGINNING OF THE PROJECT AND FOR SITE INSPECTIONS DURING THE WORKS.

Date: 20-10-2020

OPTIONAL THERMAL BREAK

(SUCH AS ETHAFOAM, CELLULOSE TAPE OR

3mm LOW CONDUCTION MATERIAL NON

COMPRESSIBLE OR AFTER COMPRESSION)

AIR-BARRIER MEMBRANE

AutoCAD SHX Text
M
AutoCAD SHX Text
15
AutoCAD SHX Text
12
AutoCAD SHX Text
10
AutoCAD SHX Text
9
AutoCAD SHX Text
28
AutoCAD SHX Text
1
AutoCAD SHX Text
8
AutoCAD SHX Text
6
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
24
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
10B
Page 7: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 1

25 @ 125 MM

VARIABLE

38 MIN.

ISOMETRY

BRICK SIDINGScale: Variable

Date:20-10-2020

D-MAX WALL

25

25

Page 8: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

Date: 20-10-2020

THROUGH WALL MEMBRANE AT FOUNDATION

WALL JUNCTION - BRICK SIDING

PAGE 2

D-MAX WALL

SCALE : 1:5

25 @ 125 MM

VARIABLE

38 MIN.

75 M

IN

.

THERMAL

BREAK

AutoCAD SHX Text
8
AutoCAD SHX Text
1
AutoCAD SHX Text
15
AutoCAD SHX Text
9
AutoCAD SHX Text
1
AutoCAD SHX Text
M
AutoCAD SHX Text
6
AutoCAD SHX Text
28
Page 9: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

WINDOW SILL

BRICK SIDING

Date: 20-10-2020

PAGE 3

SCALE: 1:2.5

25 @ 125 MM

VARIABLE

38 MIN.

D-MAX WALL

AutoCAD SHX Text
D
AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
N
Page 10: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

WINDOW JAMB

BRICK SIDING

Date: 20-10-2020

PAGE 4

SCALE: 1:2.5

25 @

125

MM

VA

RIA

BLE

D-MAX WALL

38 M

IN

.

INJECTION DRILLING

@ 400mm C/C (16'') IF

REQUIRED

NOTE: FOR SUPPORT PURPOSES AT

OPENINGS, THE WINDOW SUPPORT

POSTS MAY BE DOUBLED AND

INJECTED WITH HEATLOK SOYA.

AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
N
Page 11: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

TOP OF WINDOW

BRICK SIDING

Date: 20-10-2020

PAGE 5

SCALE: 1:2.5

25 @ 125 MM

VARIABLE

38 MIN.

D-MAX WALL

AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
10
AutoCAD SHX Text
2
AutoCAD SHX Text
M
AutoCAD SHX Text
C
AutoCAD SHX Text
6
AutoCAD SHX Text
N
Page 12: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

Date: 20-10-2020

FLOOR JUNCTION

BRICK SIDING

PAGE 6

SCALE : 1:5

38 MIN.

VARIABLE

25 @ 125

MM

75 M

IN

.

150 M

IN

.

D-MAX WALL

FIRESTOP AND

SMOKE BARRIER

IF REQUIRED

THERMAL BREAK

25

25

DEFLECTION

TRACK

AutoCAD SHX Text
M
AutoCAD SHX Text
6
AutoCAD SHX Text
10
Page 13: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

Date: 20-10-2020

DETAIL AT WALL PENETRATION

BRICK SIDING

PAGE 7

SCALE : 1:5

38 MIN.

25 @

125 MM VARIABLE

75 M

IN

.75 M

IN

.

D-MAX WALL

AutoCAD SHX Text
M
AutoCAD SHX Text
10
Page 14: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

Date: 20-10-2020

COLUMN AND WALL JUNCTION - BUILDING CORNER

BRICK SIDINGSCALE : 1:5

D-MAX WALL

PAGE 8

150 M

IN

.

SEMI-RIGID INSULATION BOARD

VARIABLE THICKNESS

25

25

INJECTION DRILLING

@ 400mm C/C (16'') IF

REQUIRED

AutoCAD SHX Text
M
AutoCAD SHX Text
10B
AutoCAD SHX Text
N
AutoCAD SHX Text
10
AutoCAD SHX Text
M
Page 15: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

Date: 20-10-2020

FIRE SEPARATION

BRICK SIDING

SCALE : 1:5

D-MAX WALL

INSULATION

PAGE 9

2 GYPSUM BOARDS

ACCORDING TO REQUIRED

FIRE RESISTANCE

POLYETHYLENE VAPOR

BARRIER BETWEEN THE 2

GYPSUM BOARDS

(OPTIONAL FOR ODORS

BETWEEN UNITS)

HEATLOK SOYA HFO

FIRESTOP SEALANT

Page 16: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 10

38 MIN.

25 @

125 MM

VARIABLE

Date: 20-10-2020

SCALE : 1:5

D-MAX WALL

DETAIL AT SUPPORT BEAM, PARAPET

BRICK SIDING

25

THERMAL BREAK

DEFLECTION

TRACK

AutoCAD SHX Text
M
AutoCAD SHX Text
10B
AutoCAD SHX Text
10
Page 17: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 11

VARIABLE

38 MIN.

Scale: Variable

Date:20-10-2020ISOMETRY

LIGHTWEIGHT SIDING

D-MAX WALL

25 @ 125 MM

25

25

Page 18: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 12

THROUGH WALL MEMBRANE AT FOUNDATION

WALL JUNCTION - LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE : 1:5

75 M

IN

.

25 @ 125 MM

VARIABLE

38 MIN.

D-MAX WALL

THERMAL

BREAK

AutoCAD SHX Text
M
AutoCAD SHX Text
10
AutoCAD SHX Text
6
AutoCAD SHX Text
8
AutoCAD SHX Text
1
AutoCAD SHX Text
15
AutoCAD SHX Text
9
AutoCAD SHX Text
1
AutoCAD SHX Text
28
Page 19: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 13

WINDOW SILL

LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE: 1:2.5

25 @ 125 MM

VARIABLE

38 MIN.

D-MAX WALL

AutoCAD SHX Text
M
AutoCAD SHX Text
D
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
N
Page 20: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 14

89

PATIO DOOR SILL

LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE: 1:2.5

D-MAX WALL

INJECTION

DRILLING @

400MM C/C IF

REQUIRED

25 89

AutoCAD SHX Text
M
AutoCAD SHX Text
D
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
3
Page 21: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 15

WINDOW JAMB

LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE: 1:2.5

25 @

125

MM

VA

RIA

BLE

D-MAX WALL

38 M

IN

.

INJECTION DRILLING

@ 400mm C/C (16'') IF

REQUIRED

NOTE: FOR SUPPORT PURPOSES AT

OPENINGS, THE WINDOW SUPPORT

POSTS MAY BE DOUBLED AND

INJECTED WITH HEATLOK SOYA.

AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
N
Page 22: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 16

TOP OF WINDOW

LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE: 1:2.5

25 @ 125 MM

VARIABLE

38 MIN.

D-MAX WALL

AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
M
AutoCAD SHX Text
C
AutoCAD SHX Text
6
AutoCAD SHX Text
N
Page 23: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 17

Date: 20-10-2020

38 MIN.

FLOOR JUNCTION

LIGHTWEIGHT SIDINGSCALE : 1:5

75 M

IN

.

25 @ 125

MM VARIABLE

D-MAX WALL

FIRESTOP AND

SMOKE BARRIER

IF REQUIRED150 M

IN

.

THERMAL BREAK

25

25

DEFLECTION

TRACK

AutoCAD SHX Text
M
AutoCAD SHX Text
10
Page 24: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 18

DETAIL AT WALL PENETRATION

LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE : 1:5

38 MIN.

25 @

125 MM VARIABLE

75 M

IN

.75 M

IN

.

D-MAX WALL

AutoCAD SHX Text
10
AutoCAD SHX Text
M
Page 25: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

COLUMN AND WALL JUNCTION - BUILDING CORNER

LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE : 1:5

D-MAX WALL

PAGE 19

150 M

IN

.

SEMI-RIGID INSULATION BOARD

VARIABLE THICKNESS

25

25

INJECTION DRILLING

@ 400mm C/C (16'') IF

REQUIRED

AutoCAD SHX Text
M
AutoCAD SHX Text
10B
AutoCAD SHX Text
N
AutoCAD SHX Text
10
AutoCAD SHX Text
M
Page 26: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

Date: 20-10-2020

SCALE : 1:5

D-MAX WALL

PAGE 20

INSULATION

2 GYPSUM BOARDS

ACCORDING TO REQUIRED

FIRE RESISTANCE

POLYETHYLENE VAPOR

BARRIER BETWEEN THE 2

GYPSUM BOARDS

(OPTIONAL FOR ODORS

BETWEEN UNITS)

HEATLOK SOYA HFO

FIRESTOP SEALANT

FIRE SEPARATION

LIGHTWEIGHT SIDING

Page 27: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 21

38 MIN.

25 @

125 MM

VARIABLE

Date: 20-10-2020

SCALE : 1:5

D-MAX WALL

DETAIL AT SUPPORT BEAM, PARAPET

LIGHTWEIGHT SIDING

25

THERMAL BREAK

DEFLECTION

TRACK

AutoCAD SHX Text
M
AutoCAD SHX Text
10B
AutoCAD SHX Text
10
Page 28: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 22

OPTIONS

Date: 20-10-2020

D-MAX WALL

Page 29: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 23

25 @ 125 MM

VARIABLE

38 MIN.

75 M

IN

.

OPTION

WINDOW SILL

BRICK SIDING

Date: 20-10-2020

SCALE: 1:2.5

D-MAX WALL

AutoCAD SHX Text
M
AutoCAD SHX Text
D
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
Page 30: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 24

25 @

125

MM

VA

RIA

BLE

38 M

IN

.

OPTION

WINDOW JAMB

BRICK SIDING

Date: 20-10-2020

SCALE: 1:2.5

D-MAX WALL

INJECTION DRILLING

@ 400mm C/C (16'') IF

REQUIRED

NOTE: FOR SUPPORT PURPOSES AT

OPENINGS, THE WINDOW SUPPORT

POSTS MAY BE DOUBLED AND

INJECTED WITH HEATLOK SOYA.

AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
N
Page 31: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 25

25 @ 125 MM

VARIABLE

38 MIN.

OPTION

75 M

IN

.

TOP OF WINDOW

BRICK SIDING

Date: 20-10-2020

SCALE: 1:2.5

D-MAX WALL

AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
M
AutoCAD SHX Text
C
AutoCAD SHX Text
6
Page 32: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 26

25 @ 125 MM

VARIABLE

38 MIN.

OPTION

75 M

IN

.

WINDOW SILL

LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE: 1:2.5

D-MAX WALL

AutoCAD SHX Text
M
AutoCAD SHX Text
D
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
Page 33: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 27

25 @

125

MM

VA

RIA

BLE

38 M

IN

.

OPTION

WINDOW JAMB

LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE: 1:2.5

D-MAX WALL

INJECTION DRILLING

@ 400mm C/C (16'') IF

REQUIRED

NOTE: FOR SUPPORT PURPOSES AT

OPENINGS, THE WINDOW SUPPORT

POSTS MAY BE DOUBLED AND

INJECTED WITH HEATLOK SOYA.

AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
N
Page 34: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 28

25 @ 125 MM

VARIABLE

38 MIN.

OPTION

75 M

IN

.

TOP OF WINDOW

LIGHTWEIGHT SIDING

Date: 20-10-2020

SCALE: 1:2.5

D-MAX WALL

AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
M
AutoCAD SHX Text
C
AutoCAD SHX Text
6
Page 35: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 29

OPTION

75 M

IN

.

38 MIN.

25 @ 125

MM VARIABLE

150 M

IN

.

THERMAL BREAK

FIRESTOP AND

SMOKE BARRIER

IF REQUIRED

FLOOR JUNCTION

BRICK SIDING

Date: 20-10-2020

SCALE : 1:5

D-MAX WALL

25

25

DEFLECTION

TRACK

AutoCAD SHX Text
M
AutoCAD SHX Text
6
AutoCAD SHX Text
10
Page 36: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

PAGE 30

38 MIN.

VARIABLE

25 @ 125

MM

75 M

IN

.

150 M

IN

.

25

25

50% COMPRESSED INTERIOR

ROCK WOOL FIRESTOP.

ONLY REQUIRED IF AIR

SPACE GREATER THAN 25mm

AND MORE THAN 3m FROM

SLAB TO SLAB

THERMAL BREAK

DEFLECTION

TRACK

FIRESTOP AND

SMOKE BARRIER

IF REQUIRED

OPTION

FLOOR JUNCTION

BRICK SIDING

Date: 20-10-2020

SCALE : 1:5

D-MAX WALL

50

AutoCAD SHX Text
M
AutoCAD SHX Text
6
AutoCAD SHX Text
10
Page 37: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

___________________________________________________________________________________________ 398, Vincent-Chartrand, Laval, Québec H7L 5L1 450-736-0774 [email protected]

28 août 2019 A/S Maxime Duzyk Demilec 870, Curé Boivin Boisbriand, Québec J7G 2A7 Projet : Coupe de mur avec barres en Z -- Demilec Suite à votre demande et à nos discussions, vous trouverez ci-dessous les recommandations préliminaires concernant les épaisseurs requises des barres en Z @ 24'' c/c pour des profondeurs variant de 1'' @ 5''. Charges mortes considérées: 6 lb/pi2

Panneau de mur en acier: 1.5 lb/pi2 Panneau Glasroc 5/8'': 2.5 lb/pi2 Barre omega: 0.5 lb/pi2 Barre Z: 0.5 lb/pi2 Isolant: 1.0 lb/pi2

Épaisseur des barres en Z selon leur profondeur

Profondeur de 1'' @ 2'' : Calibre 20 requis (0.0359'') Profondeur de 2'' @ 3 1/2'' : Calibre 18 requis (0.0478'') Profondeur de 3 1/2'' @ 5'' : Calibre 16 requis (0.0598'')

Ces recommandations doivent être confirmées par l'ingénieur en structure des colombages métalliques du projet. Il doit tenir compte des charges de vent spécifiques pour chaque projet en plus des charges mortes. Les connexions des barres en Z aux colombages métalliques doivent également être spécifiées par ce dernier. N'hésitez pas à communiquer avec nous pour des commentaires ou des questions.

Ronald Beaucage ing. Beaucage Experts-Conseils

Page 38: D-Max Wall - Huntsman Building Solutions · 2021. 1. 4. · d-max wall legend 1) the advantage of this wall section is a maximum effective r value in a very thin wall. this increases

FWF07.EW25 - EXTERIOR WALL SYSTEMS CERTIFIED FOR CANADA

See General Information for Exterior Wall Systems Certified for Canada

System No. EW25December 02, 2019

Exterior Wall Systems Certified for CanadaTested in accordance with a fifteen minute fire exposure as per: National Building Code of Canada 2015, clause 3.2.3.8(1)(b), and National Building Code of Canada

2010, clause 3.2.3.8(1)(b)

1. Floor and Ceiling Tracks — (Not shown) 92 mm deep by 32 mm wide channel, 0.48 mm thick galvanized steel, attached to masonry or concrete with fasteners spaced 610 mm OC.

2. Steel Studs — 92 mm deep by 38 mm wide channel, with 6 mm lip, 0.48 mm(26 gauge) thick galvanized steel, spaced 406 mm OC, fastened to the floor and ceiling tracks. Steel studs must extend a minimum of 25mm above the finished surface of item 6.

3. C-Channel — 127mm deep by 38 mm wide C-channel, 0.91 mm thick (20 gauge) galvanized steel, 3050 mm long, fastened to item 2. C-channel located along the perimeter of the wall assembly. C-Channel depth may be reduced depending on installed thickness of item 6.

4. Z-bar — 127 mm deep by 38 mm wide Z-bar, 0.91 mm thick galvanized steel,3050 mm long, fastened to item 2. Z-bar located at maximum 610 mm OC. Z-bar oriented horizontally. Z-bar depth may be reduced depending on installed thickness of item 6.

5. Gypsum Sheathing — Minimum one layer of minimum 12.7 mm thick, UL Classified or ULC Listed, exterior gypsum sheathing, attached to steel studs and floor and ceiling track with Type S screws, 25 mm long, spaced 305 mm OC along edges of board in the field of the board.CERTAINTEED GYPSUM INC — GlasRocGEORGIA-PACIFIC GYPSUM LLC — Type DGG, DensGlass Gold SheathingUNITED STATES GYPSUM CO — USG SECUROCK® Sheathing

6. Foamed plastic — Spray applied, foamed plastic insulation , maximum 32.7 kg/m3, to a maximum depth of 204 mm.DEMILEC INC — Airmétic Soya, Heatlok Soya, Polarfoam Soya, Airmétic Soya HFO, Heatlok Soya HFO, Polarfoam Soya HFO.

7. Gypsum Wallboard — Minimum one layer of minimum 12.7 mm thick, UL Classified or ULC Listed, interior gypsum wallboard, attached to steel studs and floor and ceiling track with 3 mm diameter self-drilling screws, 25 mm long, spaced 305 mm OC along edges of board and in the field of the board.

8. Weather Protection Membrane — One layer of peel and stick vapor barrier, with50 mm (maximum) overlap on all joints. Adhered with manufacturer's recommended primer at full coverage.

Last Updated on 2019-12-02w w w . d e m i l e c . c a