d45 system - bticino · d45 system interface device used to connect the entrance panel and the...

3
1 323018 72 mm 59,5 mm 33 mm 105 mm 94 mm 1 2 POWER + - 5 6 7 8 4 3 D45 System Description Entrance panel/Switchboard shunt D45 System interface device used to connect the entrance panel and the switchboard to the system. This device automatically switches over the video channels. Must be configured. DIN RAIL installation. Technical data Power supply: 30 Vdc Stand by current absorption: ≤ 70 mA @ 30 V Max. operating current absorption: ≤ 70 mA @ 30 V Stand by power consumption: 2.1 W Operating power consumption: 2.1 W Operating temperature: (-10)-(+40)°C Dimensional data Legend 1. Configurators housing 2. Serial port interface for configuration download and firmware update 3. S1 - S2 keys for pushbuttons device configuration (NOT USED) 4. LED indicator for configuration status 5. RJ45 connector for digital entrance panel or switchboard connection 6. B2 RJ45 connector for main system BUS connection 7. B1 RJ45 connector for main system BUS connection 8. Auxiliary power supply input connector (30 V) Front view Lower view BT00463-b-EN 13/05/2013

Upload: phungphuc

Post on 14-Sep-2018

229 views

Category:

Documents


0 download

TRANSCRIPT

1

323018

72 mm

59,5 mm

33 mm

105 m

m

94 m

m

POWER+-

1 2

POWER+-

5678

43

D45 System

Description

Entrance panel/Switchboard shunt

D45 System interface device used to connect the entrance panel and the switchboard to the system. This device automatically switches over the video channels. Must be configured. DIN RAIL installation.

Technical data

Power supply: 30 VdcStand by current absorption: ≤ 70 mA @ 30 VMax. operating current absorption: ≤ 70 mA @ 30 VStand by power consumption: 2.1 WOperating power consumption: 2.1 WOperating temperature: (-10)-(+40)°C

Dimensional data Legend

1. Configurators housing

2. Serial port interface for configuration download and firmware update

3. S1 - S2 keys for pushbuttons device configuration (NOT USED)

4. LED indicator for configuration status

5. RJ45 connector for digital entrance panel or switchboard connection

6. B2 RJ45 connector for main system BUS connection

7. B1 RJ45 connector for main system BUS connection

8. Auxiliary power supply input connector (30 V)

Front view

Lower view

BT00463-b-EN 13/05/2013

2

323018

CF1 CF2 CF3 CF4 CF5 CF6

MCmin

MCmin

MCmax

MCmac DEV DIR

CF1 CF2 CF3 CF4 CF5 CF6

MCmin

MCmin

MCmax

MCmac DEV DIR

1 2 3 4 5 6

CF1 CF2 CF3 CF4 CF5 CF6

MIN MIN MAX MAX DEV DIR

0 4 0 4 0 1

CF1 CF2 CF3 CF4 CF5 CF6

MIN MIN MAX MAX DEV DIR

0 4 0 5 1 0

CF1 CF2 CF3 CF4 CF5 CF6

MIN MIN MAX MAX DEV DIR

0 4 0 5 1 1

Entrance panel/Switchboard shunt

Configuration

Two different device configuration ways available:WAY 1) Configuration settings by inserting phisical configuratorsWAY 2) Configuration by using SF2 Software and PC connection

Configuration by inserting phisical configurators - WAY 1:

Meaning of the configuration places:

*Min: the minimal number connected to the Backbone/main EP or to the switchboard at main EP/Switchboard of interface.

**Max: the maximal number connected to the Backbone/main EP or to the switchboard at main EP/Switchboard of interface.

ConfigurATion plACe Mode 1 Mode 2CF1

Min*

Same as Mode 1

CF2CF3

Max**CF4CF5 DEVCF6 DIR

deV = options of main EP/Switchboard types:

deV0 Switchboard1 Backbone/main EP

dir: options of main EP/Switchboard wiring directions:

dir0 The Switchboard is connected to the B1 interface and backbone/main EP to the B2 interface1 The backbone/main EP is connected to B1 and the Switchboard to B2

The DIR configuration for the device wiring direction must satisfy the following rules or they will lead to irregular working of the system :

1. Riser shunt must be connected at the B1 connector interface of all interface in the relevant zone.

2. The wiring direction of the switchboard and the main EP can be set through the DIR configuration place, but all of interfaces wiring directions must be identically configured in the project.

3. Pushbutton-configuration operation (it will be invalid when the configurator is inserted).

Value of the configuration place (from 0 – 9)

Code of the configuration place (1 to 6)

Configuration examples:

example (A):Item 323018 is used to extend one switchboard. The switchboard address range is 4; all main EP are installed in the B1 port of 323018, configuration as follows:

Configuration examples:

example (C):Item 323018 is used to extend one Switchboard, Switchboard address range is 4; all main EP are installed in the B1 port of 323018, configuration as follows:

posiTion Mode 1 VAlue for Config. reMArksCF1 MIN 0 xCF2 MIN 4 xCF3 MAX 0 xCF4 MAX 4 xCF5 DEV 0 xCF6 DIR 1 x

Configuration examples:

example (B):Item 323018 used to extend the main EP. The main EP address range is 4 to 5; all switch-boards are installed in the B1 port of 323018, configuration as follows:

posiTion Mode 1 VAlue for Config. reMArksCF1 MIN 0 xCF2 MIN 4 xCF3 MAX 0 xCF4 MAX 5 xCF5 DEV 1 xCF6 DIR 0 x

posiTion Mode 1 VAlue for Config. reMArksCF1 MIN 0 xCF2 MIN 4 xCF3 MAX 0 xCF4 MAX 5 xCF5 DEV 1 xCF6 DIR 1 x

BT00463-b-EN 13/05/2013

3

323018

POWER+-

X X X X 1 1 X X X X 1 1 X X X X 0 1 X X X X 0 1

X X X X 0 1X X X X 0 1

323003

323005

323018

323001 323001

323018

323004

323004 323007

323001 323001

323018 323018 323018 323018

Entrance panel/Switchboard shunt

Wiring diagram

Configuration by using sf2 software and pC connection - WAY 2:

This is the enhanced way to download the device configuration to interface device previously created by using SF2 configuration software and a personal computer. To transfer file use the configurator hardware tool 323020 serial interface.

WArning: in order for the communication to take place, floor shunt device must be powered and not physically configured.

Connect the EP

Backbone main EP

Backbone main EP

Backbone main EP

Backbone main EP

Backbone main EP

323020configuration

tool

Connect Floor shunt

BT00463-b-EN 13/05/2013