daikin catalogs, daikin middle east

22
Split SkyAir VRV Packaged Air Conditioners AIR CONDITIONERS LINE UP PCG0558 The specifications, designs, and information in this brochure are subject to change without notice. All rights reserved Printed in Japan 10/05/003 Y.K. c Dealer Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global/ 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an outdoor unit with anti-corrosion treatment. Cautions on product corrosion Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. For any inquiries, contact your local distributor. All Daikin Industries locations and subsidiaries in Japan have received environmental management system standard ISO 14001 certification. The air conditioners manufactured by Daikin Industries have received ISO 9001 certification for quality assurance. Certificate Number. JMI-0107 JQA-0495 JQA-1452 Daikin Industries, Ltd. Domestic Group Certificate Number. EC99J2044 ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the requirements of ISO 14001. About ISO 14001

Upload: lonely2004

Post on 22-Jan-2016

1.081 views

Category:

Documents


8 download

DESCRIPTION

this is the Original Daikin Catalogs for VRV Splits, and Sky air products for the middle East including the specification and the Daikin Part noDaikin Middle EastMiddle East Cooling

TRANSCRIPT

Page 1: daikin Catalogs, Daikin Middle East

SplitSkyAirVRV

Packaged Air Conditioners

AIR CONDITIONERSLINE UP

PCG0558

The specifications, designs, and information in this brochure are subject to change without notice.

All rights reservedPrinted in Japan 10/05/003 Y.K.c

DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global/

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose anoutdoor unit with anti-corrosion treatment.

Cautions on product corrosion

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer orcontractor to install those parts and accessories. Use of unauthorized parts and accessories orimproper installation of parts and accessories can result in water or refrigerant leakage, electricalshock, fire or explosion.Read the User's Manual carefully before using this product. The User's Manual provides importantsafety instructions and warnings. Be sure to follow these instructions and warnings.

For any inquiries, contact your local distributor.

All Daikin Industries locationsand subsidiaries in Japan havereceived environmentalmanagement system standardISO 14001 certification.

The air conditioners manufacturedby Daikin Industries havereceived ISO 9001 certification forquality assurance.

Certificate Number. JMI-0107JQA-0495JQA-1452

Daikin Industries, Ltd.Domestic GroupCertificate Number. EC99J2044

ISO 14001 is the standard defined by theInternational Organization for Standardization (ISO)relating to environmental management systems.Our group has been acknowledged by aninternationally accredited compliance organisationas having an appropriate programme ofenvironmental protection procedures and activitiesto meet the requirements of ISO 14001.

About ISO 14001

Page 2: daikin Catalogs, Daikin Middle East

1 2Daikin Industries Head Office

JAPAN

Daikin Europe N.V.

EUROPE

Daikin America

U.S.A.

Shanghai Daikin Airconditioning

Daikin (China) InvestmentDaikin Fluoro Coatings(Shanghai)

Huizhou Daikin SunsAirconditioning

X'ian Daikin Qing'anCompressor

Kanaoka Factory,Sakai Plant

Kashima FactoryShiga Plant

Yodogawa Plant Rinkai Factory,Sakai Plant

Reliability derived from 80 years of achievementSince it's foundation in 1924, Daikin Industries, Ltd. has constantly beendeveloping to become a global leader in an array of fields, such as airconditioning systems, refrigerants, fluorochemicals, electronics and hydraulicmachineries. In particular, Daikin holds the largest market share of bothresidential- and commercial-use air conditioning systems in Japan. It isthe world's sole manufacturer that combines research, development andmanufacturing of air conditioning systems, refrigerants and compressors.

CHINA

Daikin (China) InvestmentGuangzhou Branch

Daikin (China) InvestmentShanghai Branch

Daikin AirconditioningGermany

Daikin AirconditioningFrance

Daikin AirconditioningUK

Daikin IndustriesCzech Republic

Daikin AirconditioningSpain

Daikin AustraliaDaikin AirconditioningSingapore

Daikin Industries (Thailand)

ASIA/OCEANIA

Daikin AirconditioningItaly

Examples of installation

Ministry of Agriculture &Fisheries LaboratoryOmanApril 20027 VRV Plus

Al Nokhba Tower(Elite Residential Suites)KuwaitJune 200311 VRV Plus

Sanabel Tower HotelSaudi ArabiaJanuary 200175 VRV Plus

Awqaf TowerQatarJune 20048 VRV Plus

Contents

29.....Control Systems

42.....Water Chillers

28.....HRV

S P L I T T y pe A i r C o n di t i o n e r s

Air Cooled Split Type Air Conditioners

PACKAGEDAIR CONDITIONERS

The Intelligent Air Conditioning System

3

21

7

33

Osaka Head Office

Tokyo Head Office

Production Site

Overseas Affiliate

Sales Agent

DAIKINASAGLOBALCORPORATE CITIZEN

Osaka Head Office

Tokyo Head Office

Production Site

Overseas Affiliate

Sales Agent

Page 3: daikin Catalogs, Daikin Middle East

FT60D

Note: Availability of the products shown in this catalog varies by country.

3 4

The Split System is the ideal air conditioning solution for one room oran area of your home. Daikin air conditioners lead the industry withtheir energy savings. Each indoor unit features silent operationfunction, bringing comfort in your living room or bedroom.Daikin now has a new D series. The simple and stylish design softlyharmonizes with your living space.

Wall-mounted type...............................5

Split type air conditioners

SPLIT Type Air Conditioners

Line up

Type

Function listFunction

Model Name

Wall-mountedtype

H/P 60 HzFTY-GA

Capacity class

17,100 20,5001.42 1.72

5.0 6.04,300

BtuRT

kWkcal 5,160

FT-GA C/O 50 Hz

FT-GA C/O 60 Hz

FT-D C/O 60 Hz

Wall-mounted typeFT50/60GA FTY50/60GA

Power-airflow dual flaps

Comfortableairflow

Comfortcontroloperation

Wide-angle louvers

Vertical auto-swing

Horizontal auto-swing

Auto fan speed

W I D EA N G L E

A U T O

Lifestyleconvenience

Healthy &clean

Timer

Worry free

Power airflow flap

Air-purifying filter with photocatalytic deodorizing function

Program dry function

Automatic operation

New powerful operation

Indoor unit On/Off switch

Air-purifying filter

Mold-proof air filter

Washable grille

Filter cleaning indicator

24-hour On/Off timer

Night set mode

Auto-restart after power failure

Self-diagnosis digital display

Anticorrosion treatment of outdoor heat exchanger fin

N E WN E W

S E L F

C L E A N

2 4

Wipe-Clean flat panel

Page 4: daikin Catalogs, Daikin Middle East

5 6

Wall-mounted type5.0·6.0 kW

Air-Purifying Filter with Photocatalytic Deodorizing Function isable to remove both bacteria and viruses, in addition toeliminating mold and odors. It can be used for approximately3 years with appropriate maintenance.

High Energy SavingsDaikin air conditioners’ advanced technology allows themto achieve significant energy savings with a COP of 2.55even during periods of extended use.

Compact and Stylish Design

The compact and stylish design of Daikin unitsharmonizes with any interior decor. The innovativeflat panel of the new D series enhances this effectand also ensures optimum operation.

SPLIT Type Air Conditioners

FT-D Series

Wall-mounted type

Healthy and Clean

Unique features such as our Vertical auto-swing and Horizontal auto-swingwill keep your home wrapped in a cloud of air-conditioned comfort.

Compact and quietThe rounded contours of the compact, lightweight indoor unit allow it toharmonize smoothly with your interior decor, and an improved fan designmakes operating noise hardly noticeable.

Energy-savingUsing your air conditioner for extended periods of time is now a completelyaffordable luxury thanks to Daikin’s advanced energy-saving technology.

Comfortable

FT(Y)-GA Series

FT60DVMKModel

Indoor unit

23,500/19,1001.96/1.59

Btu/hRT

5,900/4,800kcal/h6.9/5.6kW2.71/3.10kW

19.4 to 542.55

°CDB

Power comsumption *1 (1)/(2)

Operation range (Outdoor unit)COP *1 (1)

Cooling capacity*1 (1)/(2)

R60DVLKOutdoor unit1 phase, 220 V, 60 HzPower Supply

Cooling Only (60 Hz)

Outdoor UnitIndoor Unit

5.0·6.0 kW

FT(Y)50/60GA R50G R60G

RY50G RY60G

FT50GAVEA FT60GAVEAModel

Indoor unit

18,200/18,1001.52/1.51

22,000/21,8001.83/1.82

5.34/5.304,590/4,560

6.44/6.405,540/5,500

2.01/2.00-2.19/2.18 2.42/2.41-2.51/2.502.65-2.43

19.4 to 542.66-2.56

R50GV1K R60GV1KOutdoor unit1 phase, 220-240 V, 50 Hz

Cooling Only (50 Hz)

Wirelessremote controller

ModelIndoor unitOutdoor unit

Power Supply

Cooling Only (60 Hz) Heat Pump (60 Hz)

Outdoor UnitIndoor Unit

Heating Cooling

Brand-New Sleek Flat Panel Design

FT50/60GA

Wirelessremote controller

Affordable Comfort You deserve

FT60DR60D

Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB. Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284 Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

The flap descends to blowwarm air directly downto the floor to quickly warmthe whole room.

The flap flattens out so thatcool air slides off to reachthe farthest corners of theroom.

Btu/hRT

kcal/hkWkW

°CDB

Power comsumption (220-240 V) *1 (1)/(2)

Operation range(Outdoor unit)COP (220-240 V) *1 (2)

Cooling capacity*1 (1)/(2)

Power Supply

Operation range(Outdoor unit)

kWkWPower comsumption

°CDB°CWB

Heating*2 (1)/(2)Cooling*1 (2)/(3)

CoolingHeating

COP

Btu/hkcal/hkW

RTCooling capacity*1 (2)/(3)

Btu/hkcal/hkW

RTHeating capacity*2(1)/(2)

Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB. Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB. Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

•*2:Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB. Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Cooling *1 (2)Heating *2 (2)

5.8/5.0 6.5/5.6

19,800/17,1004,990/4,300

22,200/19,1005,590/4,800

1.65/1.42 1.85/1.59

6.3/6.0 7.19/7.10

21,500/20,5005,420/5,200

24,500/24,2006,180/6,100

1.79/1.71 2.04/2.02

2.903.37

1.87/1.852.492.95

2.44/2.46

FT50GAVAL FT60GAVALR50GVAL R60GVAL

1 phase, 220 V, 60 Hz

FTY50GAVAL FTY60GAVALRY50GVAL RY60GVAL

1 phase, 220 V, 60 Hz

—19.4 to 54

-10 to 1519.4 to 54

5.6/4.5 6.8/5.6

19,100/15,4004,800/3,900

23,200/19,1005,850/4,800

1.59/1.28 1.93/1.59

— —

——

——

— —

2.57—

—2.54—

—2.18/2.50 2.68/3.06 2.00/2.30 2.61/2.97

Wipe-CleanFlat Panel

Page 5: daikin Catalogs, Daikin Middle East

Note: Availability of the products shown in this catalog varies by country.

7 8

Stores often feature the latest in designed decor. This refined beauty attractspeople.Meanwhile, offices have a functional beauty. This encourages those within towork hard and apply intelligence and passion to their tasks.In either situation, a certain elegance should fill the space because thinkingminds require high quality air conditioning. SkyAir by Daikin ensures acomfortable indoor environment. All over the world, stores, offices, and homesprefer the low operating noise, attractive design, complete comfort control,and other benefits brought by SkyAir.

Indoor units.....................................10Specifications..................................11Simultaneous operation system......16

Line UpAir Cooled Split Type Air Conditioners

Type Model Name

Ceilingmountedcassette type

FHC

FH(Y)C

FHYC

FH

FHY

H/P

C/O

H/P

C/O

2 2.5 3 4 5 6 8 10

19100 23200 27600 38900 48800 53900 81900 996001.6

5.6 6.8 8.1 11.4 14.3 15.8 24.0 29.2kWHP

BtuRT 1.9 2.3 3.2 4.1 4.5 6.8 8.3

15 20

163400 19930047.9 58.4

13.6 16.6

Simultaneous operation system

60 Hz

50 Hz

60 Hz

60 Hz

60 Hz

60 Hz

60 Hz

60 Hz

Operation system

Twin

Applicable Models

6 8 1015.8 22.2 26.653900 75700 90800

HPkWBtuRT 4.5 6.3 7.6

Ceilingsuspended type

60 Hz

50 Hz

H/P

C/OCeilingmountedbuilt-in type

50 Hz

H/P

C/OWall mountedtype

60 Hz

50 Hz

H/P

C/OFloor standingtype

60 Hz

50 Hz

H/P

C/ODuctconnectionlow staticpressuretype

Ductconnectionmiddle staticpressuretype

Ductconnectionhigh staticpressuretype

FDBG

FDB

FDYB

FV

FVY

FA

FAY

FHB

FHYB

60 Hz

50 Hz

H/P

C/O60 Hz

50 Hz

60 Hz

50 Hz

H/P

C/O60 Hz

50 Hz

60 Hz

50 Hz

H/P

C/O60 Hz

50 Hz

60 Hz

50 Hz

C/O

Ceiling mountedcassette cornertype FHK 50 Hz

Triple

DoubleTwin

Indoor unit Indoor unit

Outdoorunit

Outdoorunit

Indoor unit

Indoor unit

Indoor unit

Indoor unit

Indoor unit

Indoor unit

Indoor unit

H/P

C/O

FDMG

FD(Y)M

50 Hz

50 Hz

50 Hz

60 Hz

60 Hz

H/P

C/OFD

FDY

60 Hz

50 Hz

60 Hz

50 Hz

*1

*2

*1

*2

Notes: •Specifications for RT, Btu and kW are based on the following conditions; Power supply: 60 Hz; Cooling: Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•The values given for 2 HP to 6 HP are for the FHY(C) model and 8 HP to 20 HP are for the FD model. The values given for simultaneous operation system are for the FHYC model.•*1:FDYB and FDYM model operate for 20·25 (kW) class. •*2:FDYB and FDYM model operate for 20 (kW) class.

Packagedairconditioners

Capacity

Capacity

Outdoorunit

Page 6: daikin Catalogs, Daikin Middle East

9 10

Air Cooled Split Type Air Conditioners

Wall Mounted TypeCeiling Suspended Type

Floor Standing TypeCeiling Mounted Cassette Corner Type

Ceiling Mounted Cassette Type Ceiling Mounted Built-in Type

Indoor unitsIndoor units

R emote C ontrollerOutdoor Unit

LCD WiredRemote Controller

LCD WirelessRemote Controller

FH(Y)C

On-ceiling installation leaves floorspace unhindered. Extremelyquiet operation enhances thestore's customer service.

FH(Y)

Uni-directional discharge outlet isperfect for corner installation.A thin, 21.5 cm main bodyenables installation even in asmall ceiling overhead space.

FHK

FH(Y)B

FA(Y)

FV(Y)

Floor standing type units are easy toinstall and maintain; their slimness issuitable for installation in high-ceilingstores and offices.

Wall mounted type units featurethe lowest sound levels in theindustry and greatly upgradedcomfort, thanks to the high fanspeed mode.

With the use of simple ducts,discharge outlets can be locatedin a multitude of ways. Top prioritygiven to interior decor, built-intype units realize ideal air currentdistribution.

Quiet,decor-blending form and easyinstallation in new or old buildings.Multiple unit installations maintain aphysical uniformity that isaesthetically pleasing and make iteasier to plan ceiling lightingsystems and to design interiors.

Packaged Air Conditioners Duct Connection Series

FDB(G)FDYB FD(Y)FD(Y)M

FDMG

For details, please refer to P33-P40.

Low static pressure High static pressureMiddle static pressure

Page 7: daikin Catalogs, Daikin Middle East

11 12

Air Cooled Split Type Air Conditioners—Specifications

C ooling Only (50 Hz)

Indoor unit

Outdoor unit

Cooling capacity*1 (1)/(2)

Power supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V,50 Hz/Y1: 3 phase, 380-415 V,50 Hz

Power comsumption *1 (1)/(2)COP *1 (1)/(2)

Operation range (Outdoor temp.)

Model

Ceiling suspended type

Ceiling mounted cassette type

Power supply

71

7.8/7.7

FH71BVE100

10.6/10.5

FH100BVE125

13.0/12.8

FH125BVE

R125FUY1R71FUV1R71FUY1

R100FUV1R100FUY1

kW

Indoor unit

Outdoor unit

Cooling capacity*1 (1)/(2)

50

5.19/5.1

FH50BVE

R50GV1

60

6.6/6.5

2.2/2.2 3.0/3.0 3.7/3.6RT 1.5/1.4 1.9/1.8

FH60BVE

R60GV1K

26,600/26,3006,700/6,600

36,200/35,8009,100/9,000

44,400/43,70011,200/11,000

Btu/hkcal/h

17,700/17,4004,460/4,400

22,500/22,2005,690/5,600

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz

Model

Indoor unitOutdoor unit

Btu/hkcal/h

Cooling capacity*1 (1)/(2)

45

17,700/17,400

FHB45FV1R50GV1

4,500/4,400

60

22,500/22,200

kW 5.19/5.1 6.6/6.5

RT 1.5/1.4 1.9/1.8

FHB60FV1R60GV1K

5,700/5,600

2.23/2.202.33/2.32

2.37/2.362.78/2.76

Ceiling mounted built-in type

Power supply 1 phase, 220-240 V, 50 Hz

Model

45

5.19/5.1

FHK45FV1R50GV1

60

6.6/6.5

FHK60FV1R60GV1K

2.31/2.282.25/2.24

19.4 to 54

2.39/2.372.76/2.74

19.4 to 54

kW

1.5/1.4 1.9/1.8RT

Indoor unitOutdoor unit

17,700/17,4004,460/4,400

22,500/22,2005,690/5,600

Btu/hkcal/h

Ceiling mounted cassette corner type

Power supply 1 phase, 220-240 V, 50 Hz

Model

kW

°CDB

kW

°CDB

kW

°CDB

kWkW 5.34/5.3 6.44/6.4 7.8/7.7 10.6/10.5 13.0/12.8

kWRT 1.5/1.5 1.8/1.8 2.2/2.2 3.0/3.0 3.7/3.6Btu/hkcal/hBtu/hkcal/h

18,200/18,1004,590/4,560

22,000/21,8005,540/5,500

26,600/26,3006,700/6,600

36,200/35,8009,100/9,000

44,400/43,70011,200/11,000

2.64/2.642.02/2.01

2.63/2.622.45/2.44

3.00/2.982.60/2.58

2.87/2.883.69/3.65

2.96/2.944.39/4.35

19.4 to 54 21 to 52

19.4 to 54 21 to 52

Power comsumption *1 (1)/(2)COP *1 (1)/(2)

Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)COP *1 (1)

Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)COP *1 (1)

Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)COP *1 (1)/(2)

Operation range (Outdoor temp.)2.40/2.372.16/2.15

2.36/2.342.8/2.78 2.58/2.56

3.02/3.01 2.80/2.803.79/3.75

2.78/2.764.67/4.63

Power comsumption *1 (1)/(2)COP *1 (1)/(2)

Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)COP *1 (1)/(2)

Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)COP *1 (1)/(2)

Operation range (Outdoor temp.)

50FHC50KVE

R50GV1

60FHC60KVE

R60GV1K R125FUY1

71FHC71KVER71FUV1R71FUY1

100FHC100KVER100FUV1R100FUY1

125FHC125KVE

Model

Model

R71FUV1R71FUY1

R100FUV1R100FUY1

Indoor unit

Outdoor unit

71FA71FVEK

100

RT 2.2/2.2 3.0/3.0

FA100FVEK

3.06/3.042.55/2.53

2.94/2.953.6/3.56

Wall mounted type

Power supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz

R125FUY1R71FUV1R71FUY1

R100FUV1R100FUY1

Floor standing type

Indoor unit

Outdoor unit

71FV71LAVE

100FV100LAVE

125

kW 7.80/7.7 10.6/10.5 13.0/12.8

RT 2.2/2.2 3.0/3.0 3.7/3.6

FV125LAVE

Btu/hkcal/h

26,600/26,3006,700/6,600

36,200/35,8009,100/9,000

44,400/43,70011,200/11,000

2.92/2.912.67/2.65

2.82/2.813.76/3.74

2.9/2.884.49/4.45

Power supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz

Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)

Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)

C ooling Only (60 Hz)

ModelIndoor unit

Outdoor unit

Ceiling mounted cassette type50

FHC50KVE60

FHC60KVE71

FHC71KVE100

FHC100KVE125

FHC125KVE

R50GVAL R60GVAL R125FUTAL

125FHYC125KVE

R125KUYALK

140FHYC140KVER140KUTALKR140KUYALK

R71FUVAL R100FUVAL

Power supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

5.6/4.5 6.8/5.6 8.1/6.7 11.4/9.0 14.3/12.5kW 14.3/12.5 15.8/14.0

1.6/1.3 1.9/1.6 2.3/1.9 3.2/2.6 4.1/3.6RT 4.1/3.6 4.5/4.019,100/15,4004,800/3,900

23,200/19,1005,800/4,800

27,600/22,9007,000/5,800

38,900/30,7009,800/7,700

48,800/42,700Btu/hkcal/h 12,300/10,800

48,800/42,70012,300/10,800

53,900/47,80013,600/12,000

2.532.21/2.5

2.492.73/3.14

2.433.34/4.2

2.514.54/5.80

2.356.08/7.00

2.605.50/6.80

2.775.70/

71FH71BVE

100FH100BVE

125FH125BVE

R50GVAL R60GVAL R125FUTALR71FUVAL R100FUVAL

Ceiling suspended type

Indoor unitOutdoor unit

50FH50BVE

60FH60BVE

8.1/6.7 11.4/9.0 14.3/12.55.25/4.5 6.5/5.6kW

27,600/22,9007,000/5,800

38,900/30,7009,800/7,700

48,800/42,70012,300/10,800

17,900/15,4004,500/3,900

22,200/19,1005,600/4,800

Btu/hkcal/h

Power supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

2.353.44/4.2

2.444.67/5.80

2.296.25/7.00

2.282.3/2.5

2.292.84/3.2

Cooling capacity*1 (1)/(2)

Cooling capacity*1 (1)/(2)

Model

(For specifications of duct connection series, please refer to P35-P40.)

2.3/1.9 3.2/2.6 4.1/3.61.5/1.3 1.8/1.6RT

kW 10.6/10.57.80/7.7

Btu/hkcal/h

36,200/35,8009,100/9,000

26,600/26,3006,700/6,600

Cooling capacity*1 (1)/(2)

Cooling capacity*1 (1)/(2)

Cooling capacity*1 (1)/(2)

21 to 52

21 to 52

kW

°CDB

kW

°CDB

19.4 to 54 21 to 54

19.4 to 54 21 to 54

kW

°CDB

kW

°CDB

kW

°CDB

KUTALK.....6.80, KUYALK.....7.10

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Page 8: daikin Catalogs, Daikin Middle East

13 14

Air Cooled Split Type Air Conditioners—Specifications

Indoor unitOutdoor unit

71FA71FVEK

100

kW 8.1/6.7 11.4/9.5

RT

kW

°CDB

2.3/1.9 3.2/2.7

FA100FVEK

Btu/hkcal/h

27,600/22,9007,000/5,800

38,900/32,4009,800/8,200

2.483.27/4.1

21 to 542.59

4.41/5.70

Wall mounted type

R71FUVAL R100FUVALPower supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz

Floor standing type

Indoor unitOutdoor unit

71FV71LAVE

100FV100LAVE

125FV125LAVER125FUTALR71FUVAL R100FUVAL

8.1/6.7 11.4/9.0 14.3/12.5kW

27,600/22,900 38,900/30,700 48,800/42,7007,000/5,800 9,800/7,700 12,300/10,800

Btu/hkcal/h

Power supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz2.3/1.9 3.2/2.6 4.1/3.6RT

kW

°CDB

3.40/4.3 4.62/5.90 6.20/7.102.38 2.47 2.31

21 to 54

Cooling capacity*1 (1)/(2)

Cooling capacity*1 (1)/(2)

Model

Model

Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature:27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature:29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Power comsumption *1 (1)/(2)COP *1 (1)

Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)COP *1 (1)

Operation range (Outdoor temp.)

ModelIndoor unit

Outdoor unit

Ceiling mounted cassette type50

FHYC50KVE60

FHYC60KVE71

FHYC71KVE100

FHYC100KVE

RY50GVAL RY60GVAL RY125FUTAL RY140KUTALKRY140KUYALK

RY71FUVAL RY100FUVAL

125FHYC125KVE

140FHYC140KVE

Heating capacity*2 (1)/(2)

RTCooling capacity*1 (1)/(2)

Power supply

Power comsumption

COP

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

5.8/5.0 6.5/5.6 8.1/6.7 11.4/9.0 14.3/12.5kW 15.8/14.0

1.6/1.4 1.8/1.6 2.3/1.9 3.2/2.6 4.1/3.6 4.5/4.019,800/17,1004,990/4,300

22,200/19,1005,590/4,800

27,600/22,9007,000/5,800

38,900/30,7009,800/7,700

48,800/42,70012,300/10,800

Btu/hkcal/h

53,900/47,80013,500/12,000

6.3/6.0 7.19/7.1 9.0/8.5 12.8/11.8 16.2/15.0kW 18.1/17.0

1.8/1.7 2.0/2.0 2.6/2.4 3.6/3.4 4.6/4.3RT

Power comsumption

COP

Power comsumption

COP

5.1/4.821,500/20,5005,420/5,200

24,500/24,2006,180/6,100

30,700/29,0007,700/7,300

43,700/40,30011,000/10,100

55,300/51,20013,900/12,900

Btu/hkcal/h

61,800/58,00015,600/14,600

2.03/2.34 2.66/3.06

3.372.86

2.922.44

3.72/4.30 4.69/5.90 5.88/6.60

2.592.18

2.902.43

3.012.43

5.70/7.30

3.232.77

1.87/1.85 7.19/7.1 9.0/8.5 12.8/11.8 16.2/15.0 18.1/17.0

71FHY71BVE

100FHY100BVE

125FHY125BVE

RY50GVAL RY60GVAL RY125FUTALRY71FUVAL RY100FUVAL

Ceiling suspended type

Indoor unitOutdoor unit

50FHY50BVE

60FHY60BVE

Heating capacity*2 (1)/(2)

Cooling capacity*1 (1)/(2)

Power supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz

kW 8.1/6.7 11.4/9.0 14.3/12.55.8/5.0 6.5/5.6

RT 2.3/1.9 3.2/2.6 4.1/3.61.6/1.4 1.8/1.6Btu/hkcal/h

27,600/22,9007,000/5,800

38,900/30,7009,800/7,700

48,800/42,70012,300/10,800

19,800/17,1004,990/4,300

22,200/19,1005,590/4,800

kW 9.0/8.5 12.8/11.8 16.2/15.06.3/6.0 7.19/7.1

RT 2.6/2.4 3.6/3.4 4.6/4.31.8/1.7 2.0/2.0Btu/hkcal/h

30,700/29,0007,700/7,300

43,700/40,30011,000/10,100

55,300/51,20013,900/12,900

21,500/20,5005,420/5,200

24,500/24,2006,180/6,100

3.82/4.30 4.82/5.90 6.05/6.60

2.502.12

2.802.37

2.902.36

2.14/2.34 2.77/3.06

3.182.71

2.802.35

3.60/3.80 4.57/5.00 5.58/5.421.98/1.86 2.57/2.44

71FHYB71FVAL

100FHYB100FVAL

125FHYB125FVALIndoor unit

Outdoor unit

Ceiling mounted built-in type

RY125FUTALRY71FUVAL RY100FUVAL

9.0/8.5 12.8/11.8 16.2/15.0kW

2.6/2.4 3.6/3.4 4.6/4.3

3.82/4.30 4.76/5.90 6.05/6.70

2.522.12

2.852.39

2.912.36

3.57/3.80 4.49/5.00 5.56/5.60

RT

Heating capacity*2 (1)/(2)

30,700/29,0007,700/7,300

43,700/40,30011,000/10,100

55,300/51,20013,900/12,900

Btu/hkcal/h

8.1/6.7 11.4/9.0 14.3/12.5kW

2.3/1.9 3.2/2.6 4.1/3.6RT

Cooling capacity*1 (1)/(2)

27,600/22,9007,000/5,800

38,900/30,7009,800/7,700

48,800/42,70012,300/10,800

Btu/hkcal/h

Power supply VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz

Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Model

Model

Heat Pump (60 Hz)

RT

kWkWHeating *2 (1)/(2)

Cooling *1 (1)

Heating *2 (1)

Cooling *1 (1)/(2)

Operation range(Outdoor temp.)

19.4 to 54-10 to 15

-5 to 54-10 to 15.5 -10 to 15

°CDB°CWBHeating

Cooling

Operation range(Outdoor temp.)

°CDB°CWBHeating

Cooling

Operation range(Outdoor temp.)

°CDB°CWBHeating

Cooling

kWHeating *2 (1)/(2)Cooling *1 (1)

Heating *2 (1)

Cooling *1 (1)/(2) kW

kWHeating *2 (1)/(2)Cooling *1 (1)

Heating *2 (1)

Cooling *1 (1)/(2) kW

19.4 to 54-10 to 15

-5 to 54-10 to 15.5

-5 to 54-10 to 15.5

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

(For specifications of duct connection series, please refer to P35-P40.)

Page 9: daikin Catalogs, Daikin Middle East

15 16

Simultaneous Operation System—Twin & Triple & Double Twin Multi Application Operation

Indoor unitOutdoor unit

71FAY71FVE

100FAY100FVE

Wall mounted type

RY71FUVAL RY100FUVAL

9.0/8.5 12.8/11.8kW3.67/4.20 4.61/5.80

2.622.21

2.942.47

3.44/3.70 4.36/4.90

RTHeating capacity*2 (1)/(2)

30,700/29,0007,700/7,300

43,700/40,30011,000/10,100

Btu/hkcal/h

8.1/6.7 11.4/9.0kW

RTCooling capacity*1 (1)/(2)

27,600/22,9007,000/5,800

38,900/30,7009,800/7,700

Btu/hkcal/h

Power supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz

Floor standing type71

FVY71LAVE100

FVY100LAVE125

FVY125LAVERY125FUTALRY71FUVAL RY100FUVAL

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz

Indoor unitOutdoor unit

Heating capacity*2 (1)/(2)

RT

8.1/6.7 11.4/9.0 14.3/12.5kW

Cooling capacity*1 (1)/(2)

27,600/22,9007,000/5,800

38,900/30,7009,800/7,700

48,800/42,70012,300/10,800

Btu/hkcal/h

9.0/8.5 12.8/11.8 16.2/15.0kW

RT30,700/29,000 43,700/40,300 55,300/51,2007,700/7,300 11,000/10,100 13,900/12,900

Btu/hkcal/h

Power supply

Model

Model

Branch piping kit

Branch piping kit

Branch piping kit

•Branch piping kit is optionally available.Refrigerant piping uses terminal branching to facilitate installation

•An optional remote controller is required for one of the combination indoor units.•Optional remote controllers are a single item, and cannot operate the air conditioning individually. Indoor units should not therefore be installed in separate rooms.•If operating with optional wireless remote controllers, set one as the main unit and install a light receptor.

Precautions when selecting optional remote controller

Branch piping kit

Branch piping kit

*Typical combination

Twin Multi Application

Triple Multi Application Double Twin Multi Application

Note: This type of system does not allow individual control or independent operation ofindoor units. It is not the best choice for large rooms with partitions.

In a single-floor restaurant, for example, positioning 4 unitsat strategic locations achieves comfortable air flow thatreaches every inch of the room.

Indoor units include the super cassette type, duct connection low and middle static pressure type and ceiling suspended type.(Indoor units are limited to same capacity and type combination.)

In large interior spaces a single indoor unit may not be ableto provide uniform comfort. Installation of 2 to 4 units,distributed to consider sun light and human gatheringpatterns, can provide an effective solution.

Simultaneously operates 2 to 4 indoor units usinga single outdoor unit.

Installing multiple units iseconomical and ensures comfortLower cost of installation than for individual pair typeLess space needed for outdoor unitsEnhanced comfort from distributed indoor units

Air Cooled Split Type Air Conditioners—Specifications

3.78/4.40 4.77/6.00 6.00/6.70

2.542.14

2.832.39

2.932.38

3.55/3.90 4.52/5.15 5.53/5.60

Power comsumption

COP

Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Operation range(Outdoor temp.)

°CDB°CWBHeating

Cooling

kWHeating *2 (1)/(2)Cooling *1 (1)

Heating *2 (1)

Cooling *1 (1)/(2) kW

-5 to 54-10 to 15.5

Power comsumption

COP

Operation range(Outdoor temp.)

°CDB°CWBHeating

Cooling

kWHeating *2 (1)/(2)Cooling *1 (1)

Heating *2 (1)

Cooling *1 (1)/(2) kW

-5 to 54-10 to 15.5

2.3/1.9 3.2/2.6

2.6/2.4 3.6/3.4

2.6/2.4 3.6/3.4 4.6/4.3

2.3/1.9 3.2/2.6 4.1/3.6

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

(For specifications of duct connection series, please refer to P35-P40.)

Page 10: daikin Catalogs, Daikin Middle East

17 18

Simultaneous Operation System—Twin & Triple & Double Twin Multi Application Operation

Model Indoor unit

Outdoor unit

Cooling capacity*1 (1)/(2)

Ceiling mounted cassette type

Power supply

200 250FHYC100KVEX2

R200KUY1 R250KUY1

FHYC125KVEX2FHYC71KVEX3

FHYC60KVEX4FHYC50KVEX4

kW 27.1/26.622.5/22.2

RTBtu/hkcal/h

92,500/90,80023,300/22,900

76,800/75,70019,400/19,100

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz

Model Indoor unit

Outdoor unit

Cooling capacity*1 (1)/(2)

Ceiling mounted cassette typeHeat Pump (50 Hz)

Power supply

200 250

RY200KUY1

FHYC100KVEX2

RY250KUY1

kW 27.1/26.622.5/22.2

RT 7.7/7.66.4/6.3VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz

Ceiling suspended type

Indoor unit

Outdoor unit

Cooling capacity*1 (1)/(2)

Power supplyR200KUY1

200FHY100BVEX2

R250KUY1

250

FHY125BVEX2FHY71BVEX3

FHY60BVEX4FHY50BVEX4

kW 27.1/26.622.5/22.2

RT 7.7/7.66.4/6.3Btu/hkcal/h

92,500/90,80023,300/22,900

76,800/75,70019,400/19,100

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz

Model

Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)

•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)

FHYC71KVEX3FHYC50KVEX4

Btu/hkcal/h 23,300/22,900

76,800/75,70019,400/19,100

92,500/90,800

Heating capacity*2 (1)

kW 28.422.7

RT 8.16.4Btu/hkcal/h 24,400

77,50019,500

96,900

Model Indoor unit

Outdoor unit

Cooling capacity*1 (1)/(2)

Ceiling suspended type

Power supply

200 250

RY200KUY1

FHY100BVEX2

RY250KUY1

kW

RT

RT

FHY71BVEX3FHY50BVEX4

Btu/hkcal/h

Heating capacity*2 (1)

kW

Btu/hkcal/h

FHYC125KVEX2

FHYC60KVEX4

FHY125BVEX2

FHY60BVEX4

C ooling Only (50 Hz)

COP *1 (1)/(2)

COP *1 (1)/(2)

kW

°CDB -5 to 52

Power comsumption *1 (1)/(2)

Operation range (Outdoor temp.)

kW

°CDB

7.7/7.6 9.7/9.7

7.7/7.6 9.7/9.7

2.92/2.92 2.79/2.74

7.7/7.66.4/6.3

2.92/2.92 2.79/2.74

-5 to 52

Power comsumption *1 (1)/(2)

Operation range (Outdoor temp.)

7.7/7.6 9.7/9.7

3.492.92/2.92

3.092.79/2.74

6.5 9.2Power comsumption

COP

kWHeating *2 (1)Cooling *1 (1)/(2)Heating *2 (1)

Cooling *1 (1)/(2) kW

Power comsumption

COP

kWHeating *2 (1)Cooling *1 (1)/(2)

Heating *2 (1)

Cooling *1 (1)/(2) kW

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)

•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

27.1/26.622.5/22.2

7.7/7.66.4/6.3

23,300/22,90076,800/75,70019,400/19,100

92,500/90,800

28.422.7

8.16.4

24,40077,50019,500

96,900

7.7/7.6 9.7/9.7

3.492.92/2.92

3.092.79/2.74

6.5 9.2

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz

(For specifications of duct connection series, please refer to P35-P40.)

Page 11: daikin Catalogs, Daikin Middle East

15.8/14.0 26.6/24.122.2/20.0

19 20

Simultaneous Operation System—Twin & Triple & Double Twin Multi Application Operation

Indoor unit

Outdoor unit

Ceiling mounted cassette type

Cooling capacity*1 (1)/(2)

Power supply

R140KUTALK

140

FHYC71KVEX2

200 250

R200KUTAL

FHYC100KVEX2

R250KUTALR200KUYAL R250KUYAL

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

C ooling Only (60 Hz)

kW 15.8/14.0 22.2/20.0 26.6/24.1

Btu/hkcal/h

53,900/47,80013,500/12,000

75,700/68,20019,100/17,200

90,800/82,20022,900/20,700

RT

°CDB

kW

°CDB

kW

4.5/4.0 6.3/5.7 7.6/6.8

2.775.70/6.80

21 to 542.71

8.20/10.02.61

10.20/12.5

-5 to 54

4.5/4.0 6.3/5.7 7.6/6.8

2.775.70/6.90

2.718.20/10.0

2.6110.20/12.5

FHYC50KVEX3FHYC71KVEX3FHYC50KVEX4 FHYC60KVEX4

140

FHY71BVEX2

FHY50BVEX3

200FHY100BVEX2FHY71BVEX3FHY50BVEX4

250

FHY125BVEX2

FHY60BVEX4

R140KUTALKR200KUTAL R250KUTALR200KUYAL R250KUYAL

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

Ceiling suspended type

ModelIndoor unit

Outdoor unit

Cooling capacity*1 (1)/(2)

Power supply

15.8/14.0kW 22.2/20.0 26.6/24.1

RT 6.3/5.753,900/47,80013,500/12,000

Btu/hkcal/h

75,700/68,20019,100/17,200

90,800/82,20022,900/20,700

140FHYC71KVEX2

FHYC50KVEX3

Ceiling mounted cassette type200 250

FHYC100KVEX2FHYC50KVEX4FHYC71KVEX3

FHYC125KVEX2

FHYC60KVEX4

RY140KUTALK RY200KUTAL RY250KUTALRY200KUYAL RY250KUYAL

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

Indoor unit

Outdoor unit

Heating capacity*2 (1)/(2)

15.8/14.0 26.6/24.122.2/20.0kW

kWkW

4.5/4.0 7.6/6.86.3/5.7

4.5/4.0 7.6/6.86.3/5.7

RTCooling capacity*1 (1)/(2)

18.1/17.0 28.4/28.022.7/22.4kW

5.1/4.8 8.1/8.06.4/6.4RT61,900/58,00015,600/14,600

97,000/95,60024,400/24,100

77,500/76,50019,500/19,300

Btu/hkcal/h

Power supply

Heat Pump (60 Hz)

53,900/47,80013,500/12,000

90,800/82,30022,900/20,700

75,800/68,300Btu/hkcal/h 19,100/17,200

5.7/6.9 10.2/12.5

3.232.77

-5 to 542.932.61

0 to 543.242.71

5.6/5.7 9.7/9.97.0/7.18.2/10.0

RY140KUTALK

140

FHY71BVEX2

FHY50BVEX3RY200KUTAL

200FHY100BVEX2FHY71BVEX3FHY50BVEX4

RY250KUTALRY200KUYAL RY250KUYAL

250

FHY125BVEX2

FHY60BVEX4

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

Ceiling suspended type

Indoor unit

Outdoor unit

Heating capacity*2 (1)/(2)

kW

Cooling capacity*1 (1)/(2)

Power supplyRTBtu/hkcal/h

53,900/47,80013,500/12,000

90,800/82,20022,900/20,700

75,700/68,20019,100/17,200

kW 18.1/17.0 28.4/28.022.7/22.4

RT 5.1/4.8 8.1/8.06.4/6.4Btu/hkcal/h

61,800/58,00015,600/14,600

96,900/95,50024,400/24,100

77,500/76,40019,500/19,300

ModelModel

Model

Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

FHYC125KVEX2

Power comsumption *1 (1)/(2)COP *1 (1)

Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)COP *1 (1)

Operation range (Outdoor temp.)

Power comsumption

Operation range(Outdoor temp.)

COP

Heating *2 (1)/(2)Cooling *1 (1)

Heating *2 (1)

Cooling *1 (1)/(2)

HeatingCooling °CDB

°CWB

kWkW 6.0/7.2 10.2/12.5

3.072.63

2.932.61

3.242.71

5.9/6.0 9.7/9.97.0/7.18.2/10.0Power comsumption

Operation range(Outdoor temp.)

COP

Heating *2 (1)/(2)Cooling *1 (1)

Heating *2 (1)

Cooling *1 (1)/(2)

HeatingCooling °CDB

°CWB

-10 to 15

-5 to 54 0 to 54-10 to 15

-5 to 54

5.7/6.92.77

8.2/10.02.71

10.2/12.52.61

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

(For specifications of duct connection series, please refer to P35-P40.)

Page 12: daikin Catalogs, Daikin Middle East

Note: Availability of the products shown in this catalogue varies by country.

21 22

Rising energy and general building services running costs have led end users toexpect a truly complete and acceptable air conditioning system. It must be energyefficient, economic to run, easy to install, flexible, reliable and user friendly.Featuring inverter technology and individual control, the VRV systemrevolutionised building air conditioning the world over by meeting all theserequirements, and has been installed in various buildings throughout the world forthe last 20 years.

Line Up

Indoor Units.................................24VRV II Series...............................25

HRV (Heat Reclaim Ventilation)..28

Control Systems..........................29

VRV K Series...............................27

HRV(Heat Reclaim Ventilation)

VAM150 VAM250 VAM350 VAM500 VAM650 VAM800 VAM1000 VAM1500 VAM2000

Air flow rate (m3/h)

VRV K series

Capacity Range (HP)8

The Intelligent Air Conditioning System

Air Treatment Equipment

Note: • Specifications for RT, Btu and kW are based on the following conditions;Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.

R410ASeries

Heat pumpType

67.2 72.850.4 56.0 78.4 84.022.4 28.0 44.824 2618 20 28 308 10 16

19.1 20.714.3 15.9 22.3 23.96.4 8.0 12.7229300 248400172000 191100 267500 28660076400

kWHP

RTBtu 95500 152900

Heat pumpType

VRV II Series

50 Hz

60 Hz

Capacity

Page 13: daikin Catalogs, Daikin Middle East

2324

FXCQ-MVE FXSQ-MVE

FXHQ-MVE FXNQ-MVEFXLQ-MVE

FXKQ-MVEFXFQ-MVE

FXMQ-MVE FXAQ-MVE

Thin, lightweight, and easy toinstall in narrow ceiling space

New super cassette typeis compact, quiet andeasy to install

Slim design for flexibleinstallation

Highly flexible for variousapplication

High static pressure allowsflexible duct design

Slim body with quieterand wider air flow

Sophisticated design andcompact casing harmonized inany interior décor

Perfect unit for perimeterzone air conditioning

Perfect unit to be concealed inthe skirting-wall of perimeter

Ceiling Mounted Cassette<Multi flow> Type

Ceiling Mounted Cassette<Double flow> Type

Ceiling MountedCassette Corner Type

FXDQ-NVE(T)*

Slim design, quietness andstatic pressure switching

Slim Ceiling MountedDuct Type

Ceiling MountedBuilt-in Type

Ceiling Mounted Duct Type Ceiling Suspended Type Wall Mounted Type Floor Standing Type ConcealedFloor Standing Type

Indoor unitsIndoor unitsThe series comprises a wide range of indoor units designedto meet virtually any installation site requirement.

Indoor Units

Ceiling Mounted Cassette (Double flow)Ceiling Mounted Cassette (Multi flow) Super Cassette

FXCQ-MVE

Type Modelname

FXFQ-MVE

New Ceiling Suspended Cassette FXUQ-MV1

Type Modelname

0.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 3 HP 4 HP 5 HP

7500 9600 12300 15400 19100 27300 38200 478000.6 ton

20 25 31.25 40 50 71 100 125IndexHP

BtuRT 0.8 ton 1.0 ton 1.3 ton 1.6 ton 2.3 ton 3.2 ton 4.0 ton

ConnectableOutdoorUnit

Cooling Only & Heat Pump

1 phase, 220-240 V/220 V, 50/60 HzPower supplyIndoor unit 20Model

Cooling capacity (1)/(2)

25

2,000/1,900

2,200

32

2,500/2,400

2,800

40

3,200/3,100

3,400

50

4,000/3,900

4,300

63

5,000/4,800

5,400

6,300/6,100

6,900

80

8,000/7,700

8,600

71

7,100/6,900

7,700

100

10,000/9,600

10,800

125

12,500/12,000

13,800

200

19,800/19,300

21,500

250

kW 2.3/2.2 2.9/2.8 3.7/3.6 4.7/4.5 5.8/5.6 7.3/7.1 9.3/9.08.3/8.0 11.6/11.2 14.5/14.0 23.0/22.4 28.8/28.0

RT 0.7/0.6 0.8/0.8 1.1/1.0 1.3/1.3 1.6/1.6 2.1/2.0 2.6/2.62.4/2.3 3.3/3.2 4.1/4.0 6.5/6.4 8.2/8.0Btu/h 7,800/7,500 9,900/9,600 12,600/12,300 16,000/15,400 19,800/19,100 24,900/24,200 31,700/30,70028,300/27,300 39,600/38,200 49,500/47,800 78,500/76.400 98,300/95,500

24,800/24,100

27,100Heating capacity

2.5 3.2 4.0 5.0 6.3 8.0 10.09.0 12.5 16.0 25.0 31.5kW

0.7 0.9 1.1 1.4 1.8 2.3 2.82.6 3.6 4.5 7.1 8.9RT8,500 10,900 13,600 17,000 21,500 27,300 34,10030,700 42,700 54,600 85,300 107,500Btu/h

kcal/h

kcal/h

Notes: • Cooling capacity is based on indoor temp.(1)27°CDB, 19.5°CWB, and outdoor temp. 35°CDB.(2)27°CDB, 19.0°CWB, and outdoor temp. 35°CDB.

• Heating : Indoor temp. of 20°CDB, of 7°CDB, 6°CWB.• Equivalent piping length : 7.5 m.• Level difference : 0 m.

Ceiling Mounted Cassette Corner

Ceiling Mounted Built-in

Ceiling Suspended

Floor StandingConcealed Floor Standing

Ceiling Mounted DuctFXHQ-MVEFXAQ-MVE

FXSQ-MVE

FXKQ-MVE

FXLQ-MVEFXNQ-MVE

FXMQ-MVE

0.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP 5 HP 8 HP 10 HP

7500 9600 12300 15400 19100 24200 30700 38200 47800 76400 955000.6 ton

20 25 31.25 40 50 62.5 80 100 125 200 250IndexHP

BtuRT 0.8 ton 1.0 ton 1.3 ton 1.6 ton 2.0 ton 2.6 ton 3.2 ton 4.0 ton 6.4 ton 8.0 ton

Slim Ceiling Mounted Duct FXDQ-NVE

Wall Mounted

Floor StandingFXAQ-MHV1FXLQ-MHV1

Wall Mounted

FXAQ-MHV1 FXLQ-MHV1

Wall Mounted Floor S tanding

FXUQ-MV1

New C eiling S uspendedC assette

*FXDQ-NVE: with a drain-up pump (750 mm lift) as a standard accessoryFXDQ-NVET: without a drain-up pump

FXDQ-NVET

Connection unit series (50 Hz only)

• Indoor units in the 63 class are not available for the above models.• Connection unit BEVQ-M is necessary for each indoor unit.

BEVQ-MVE

C onnec tion unit for indoor unit

H/P

H/P

H/P

H/P: Heat Pump Type

withdrain-up pumpwithoutdrain-up pump

Capacity

Capacity

Notes: • Specifications for RT and Btu are based on the following conditions;Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.

Note: • Specifications for RT and Btu are based on the following conditions; Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.

Page 14: daikin Catalogs, Daikin Middle East

25

Line Up

Series

8 10 16 18 20 24 26 28 30

6.4 8.0 12.7 14.3 15.9 19.1 20.7 22.3 23.976400

HP22.4 28.0 44.8 50.4 56.0 67.2 72.8 78.4 84.0kW

RTBtu 95500 152900 172000 191100 229300 248400 267500 286600

Heat pump type RXYQ24MY1K(E)RXYQ26MY1K(E)RXYQ28MY1K(E)RXYQ30MY1K(E)

RXYQ16MY1K(E)RXYQ18MY1K(E)RXYQ20MY1K(E)

HEAT PUMP TYPE

16, 18, 20 HP

RXYQ8MY1K(E)RXYQ10MY1K(E)

8, 10 HP 24, 26, 28, 30 HP

(50 Hz) RXYQ24MYLK(E)RXYQ26MYLK(E)RXYQ28MYLK(E)RXYQ30MYLK(E)

RXYQ16MYLK(E)RXYQ18MYLK(E)RXYQ20MYLK(E)

16, 18, 20 HP

RXYQ8MYLK(E)RXYQ10MYLK(E)

8, 10 HP 24, 26, 28, 30 HP

(60 Hz)

HEAT PUMP TYPE

Note : 1. Optional models (-E type) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric component box, in addition to the fins ofthe heat exchanger. These models are designed specifically for use in areas which are subject to salt damage and atmospheric pollution. Please contact Daikin for more information.

2. Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB.

(*2) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 46°CDB.(*3) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35°CDB.(*4) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 46°CDB.

•Heating : (*5) Indoor temp. of 20°CDB, and outdoor temp. 7°CDB/6°CWB.•Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation,

these values are normally somewhat higher as a result of ambient conditions.

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Outdoor units (50Hz) Outdoor units (60Hz)

Heat Pump Type (50 Hz) Heat Pump Type (60 Hz)

26

Capacity

Note: • Specifications for RT, Btu and kW are based on the following conditions;Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.

Line Up

Series

8 10 16 18 20 24 26 28 30

6.4 8.0 12.7 14.3 15.9 19.1 20.7 22.3 23.976400

HP22.4 28.0 44.8 50.4 56.0 67.2 72.8 78.4 84.0kW

RTBtu 95500 152900 172000 191100 229300 248400 267500 286600

Heat pump type

Capacity

Note: • Specifications for RT, Btu and kW are based on the following conditions;Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.

Heating capacity(*5)

Cooling capacity(*1)/(*2)

Btu/hkcal/h

kW

Btu/hkcal/h

Power supply

25.021,50085,300

31.527,100107,500

50.043,000170,600

19,900/19,600

6.6/6.5

24,300/20,700

8.0/6.8

39,700/39,200

13.1/13.0

56.548,600192,800

44,100/40,300

14.6/13.3

63.054,200215,000

7.1 8.9 14.2 16.0 17.9

48,500/41,500

16.0/13.778,800/77,800 96,200/82,200 157,600/155,600 175,000/160,000 192,400/164,500

kW

RT

23.1/22.8 28.2/24.1 46.2/45.6

28.0/24.1 44.8/44.8

51.3/46.9

50.4/46.5

56.4/48.2

56.0/48.2

Power consumption Cooling (*3)/(*4) kWHeating (*5)

6.01/9.16 7.58/9.56 12.0/18.35.82 7.40 11.6

13.6/18.713.2

15.2/19.1Cooling (*1)/(*2) 6.31/9.41 7.60/9.58 12.6/18.8 13.9/19.0 15.2/19.2

14.8

Operation range CoolingHeating

°CDB°CWB

-5 to 50-20 to 16

Operation range CoolingHeating

°CDB°CWB

-5 to 50-20 to 16

COP (Cooling) (*3)/(*4)COP (Heating) (*5)

3.73/2.45 3.69/2.52 3.73/2.454.30 4.26 4.30

3.71/2.484.27

3.69/2.52COP (Cooling) (*1)/(*2) 3.66/2.42 3.71/2.52 3.66/2.42 3.69/2.47 3.71/2.52

4.26

3 phase, 380–415V, 50Hz

RXYQ8MY1K(E) RXYQ10MY1K(E) RXYQ16MY1K(E) RXYQ18MY1K(E) RXYQ20MY1K(E)MODEL

RT

Cooling capacity(*3)/(*4)

Btu/hkcal/h 19,300/19,300

6.4/6.4

24,100/20,700

8.0/6.8

38,500/38,500

12.7/12.7

43,300/40,000

14.3/13.2

48,200/41,500

15.9/13.776,400/76,400 95,500/82,200 152,900/152,900 172,000/158,700 191,100/164,500

kW 22.4/22.4

RT

ConstituentUnits — — RXYQ8MY1K(E)

RXYQ8MY1K(E)RXYQ8MY1K(E)RXYQ10MY1K(E)

RXYQ10MY1K(E)RXYQ10MY1K(E)

Power supply

75.064,500255,900

81.570,100278,100

88.075,700300,300

94.581,300322,400

21.3 23.1 25.0 26.8

59,600/58,800

19.7/19.4

64,000/59,900

21.1/19.8

68,400/61,100

22.6/20.2

72,800/62,200

24.0/20.5236,500/233,400 253,900/237,800 271,300/242,300 288,700/246,700

57,800/57,800

19.1/19.1

62,600/59,300

20.7/19.6

67,400/60,700

22.3/20.1

72,200/62,200

23.9/20.5229,300/229,300 248,400/235,100 267,500/240,900 286,600/246,700

69.3/68.4 74.4/69.7 79.5/71.0

67.2/67.2 72.8/68.9 78.4/70.6

84.6/72.3

84.0/72.3

Power consumption Cooling (*3)/(*4) kWHeating (*5)

18.0/27.5 19.6/27.9 21.2/28.317.5 19.0 20.6

22.7/28.7Cooling (*1)/(*2) 18.9/28.2 20.2/28.4 21.5/28.6 22.8/28.7

22.2

COP (Cooling) (*3)/(*4)COP (Heating) (*5)

3.73/2.45 3.71/2.47 3.70/2.504.30 4.28 4.27

3.69/2.52COP (Cooling) (*1)/(*2) 3.66/2.42 3.68/2.45 3.70/2.49 3.71/2.52

4.26

RXYQ24MY1K(E) RXYQ26MY1K(E) RXYQ28MY1K(E) RXYQ30MY1K(E)MODEL

3 phase, 380–415V, 50Hz

ConstituentUnits

RXYQ8MY1K(E)RXYQ8MY1K(E)RXYQ8MY1K(E)

RXYQ8MY1K(E)RXYQ8MY1K(E)RXYQ10MY1K(E)

RXYQ8MY1K(E)RXYQ10MY1K(E)RXYQ10MY1K(E)

RXYQ10MY1K(E)RXYQ10MY1K(E)RXYQ10MY1K(E)

Heating capacity(*5)

Cooling capacity(*1)/(*2)

Btu/hkcal/h

kW

Btu/hkcal/h

kW

RT

RT

Cooling capacity(*3)/(*4)

Btu/hkcal/hkW

RT

Operation range CoolingHeating

°CDB°CWB

-5 to 50-20 to 16

Heating capacity(*5)

Cooling capacity(*1)/(*2)

Btu/hkcal/h

kW

Btu/hkcal/h

Power supply

25.021,50085,300

31.527,100107,500

50.043,000170,600

19,900/19,600

6.6/6.5

24,300/20,700

8.0/6.8

39,700/39,200

13.1/13.0

56.548,600192,800

44,100/40,300

14.6/13.3

63.054,200215,000

7.1 8.9 14.2 16.0 17.9

48,500/41,500

16.0/13.778,800/77,800 96,200/82,200 157,600/155,600 175,000/160,000 192,400/164,500

kW

RT

23.1/22.8 28.2/24.1 46.2/45.6

28.0/24.1 44.8/44.8

51.3/46.9

50.4/46.5

56.4/48.2

56.0/48.2

Power consumption Cooling (*3)/(*4) kWHeating (*5)

6.01/9.16 7.58/9.56 12.0/18.35.82 7.40 11.6

13.6/18.713.2

15.2/19.1Cooling (*1)/(*2) 6.31/9.41 7.60/9.58 12.6/18.8 13.9/19.0 15.2/19.2

14.8

COP (Cooling) (*3)/(*4)COP (Heating) (*5)

3.73/2.45 3.69/2.52 3.73/2.454.30 4.26 4.30

3.71/2.484.27

3.69/2.52COP (Cooling) (*1)/(*2) 3.66/2.42 3.71/2.52 3.66/2.42 3.69/2.47 3.71/2.52

4.26

3 phase, 380 V, 60Hz

RXYQ8MYLK(E) RXYQ10MYLK(E) RXYQ16MYLK(E) RXYQ18MYLK(E) RXYQ20MYLK(E)MODE

RT

Cooling capacity(*3)/(*4)

Btu/hkcal/h 19,300/19,300

6.4/6.4

24,100/20,700

8.0/6.8

38,500/38,500

12.7/12.7

43,300/40,000

14.3/13.2

48,200/41,500

15.9/13.776,400/76,400 95,500/82,200 152,900/152,900 172,000/158,700 191,100/164,500

kW 22.4/22.4

RT

ConstituentUnits — — RXYQ8MYLK(E)

RXYQ8MYLK(E)RXYQ8MYLK(E)RXYQ10MYLK(E)

RXYQ10MYLK(E)RXYQ10MYLK(E)

Operation range CoolingHeating

°CDB°CWB

-5 to 50-20 to 16

Power supply

75.064,500255,900

81.570,100278,100

88.075,700300,300

94.581,300322,400

21.3 23.1 25.0 26.8

59,600/58,800

19.7/19.4

64,000/59,900

21.1/19.8

68,400/61,100

22.6/20.2

72,800/62,200

24.0/20.5236,500/233,400 253,900/237,800 271,300/242,300 288,700/246,700

57,800/57,800

19.1/19.1

62,600/59,300

20.7/19.6

67,400/60,700

22.3/20.1

72,200/62,200

23.9/20.5229,300/229,300 248,400/235,100 267,500/240,900 286,600/246,700

69.3/68.4 74.4/69.7 79.5/71.0

67.2/67.2 72.8/68.9 78.4/70.6

84.6/72.3

84.0/72.3

Power consumption Cooling (*3)/(*4) kWHeating (*5)

18.0/27.5 19.6/27.9 21.2/28.317.5 19.0 20.6

22.7/28.7Cooling (*1)/(*2) 18.9/28.2 20.2/28.4 21.5/28.6 22.8/28.7

22.2

COP (Cooling) (*3)/(*4)COP (Heating) (*5)

3.73/2.45 3.71/2.47 3.70/2.504.30 4.28 4.27

3.69/2.52COP (Cooling) (*1)/(*2) 3.66/2.42 3.68/2.45 3.70/2.49 3.71/2.52

4.26

RXYQ24MYLK(E) RXYQ26MYLK(E) RXYQ28MYLK(E) RXYQ30MYLK(E)MODE

3 phase, 380 V, 60Hz

ConstituentUnits

RXYQ8MYLK(E)RXYQ8MYLK(E)RXYQ8MYLK(E)

RXYQ8MYLK(E)RXYQ8MYLK(E)RXYQ10MYLK(E)

RXYQ8MYLK(E)RXYQ10MYLK(E)RXYQ10MYLK(E)

RXYQ10MYLK(E)RXYQ10MYLK(E)RXYQ10MYLK(E)

Heating capacity(*5)

Cooling capacity(*1)/(*2)

Btu/hkcal/h

kW

Btu/hkcal/h

kW

RT

RT

Cooling capacity(*3)/(*4)

Btu/hkcal/hkW

RT

Note : 1. Optional models (-E type) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric component box, in addition to the fins ofthe heat exchanger. These models are designed specifically for use in areas which are subject to salt damage and atmospheric pollution. Please contact Daikin for more information.

2. Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB.

(*2) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 46°CDB.(*3) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35°CDB.(*4) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 46°CDB.

•Heating : (*5) Indoor temp. of 20°CDB, and outdoor temp. 7°CDB/6°CWB.•Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation,

these values are normally somewhat higher as a result of ambient conditions.

Page 15: daikin Catalogs, Daikin Middle East

27 28

Heat Reclaim Ventilation

VAM150FAVE VAM350FAVE

VAM500FAVE VAM1000FAVE

VAM1500FAVE VAM2000FAVE

HRV Remote Controller

Daikin's HRV recovers heat energy lost through ventilation and holdsdown room temperature changes caused by ventilation, therebymaintaining a comfortable and clean environment.The HRV is interlocked to Daikin's system, SkyAir and other airconditioning systems and automatically switches over ventilation mode,further increasing the effects of energy conservation.First-Class Compactness in the Industry has been achieved by employinga originally developed High Efficiency Paper (HEP) element, and using anoptimized fan and airflow passage design.First-Class Energy Conservation in the IndustryA total of 28% reduction of air conditioning load has been achievedthrough a combined use of total heat exchange mode, linked operationwith an air conditioner, and pre-heat/pre-cool control.

R emote C ontroller

The HRV creates a high-quality environmentby interlocking with the air conditioner

Indoor unit

Daikin air conditioner

LCD remote controllerfor indoor unit

• Operating mode signal• Filter cleaning signal• Failure detection signal

• ON/OFF signal• Cooling/Heating mode signal• Set temperature signal• Ventilation signal• Humidifier ON/OFF signal

HRV

• Coffee shop and restaurant • Dressmakingshop• Super market • Other variety shops• Office• Small and medium size office building• Large house• Amusement center

Shops

O f f i c e

HousingOthers

Cooling Only & Heat Pump

3 phase, 220 V, 60 HzPower supplyRSNY8KTALModel

Cooling capacity (*1)/(*2) Btu/h6.4/7.1

76,400/85,300

85,300

19,300/21,50022.4/25.07.1Heating capacity (*3) RT

RT

kWkcal/h

Btu/h

118.9/8.5Power comsumption kW

kW

2.272.52/2.94COP

Cooling (*1)/(*2)HeatingCooling (*1)/(*2)Heating

25.021,500kcal/h

kW

Notes: 1. Optional models (-E type) feature components treated for heat and rust corrosionresistance, such as external panels, fan motor, and electric component box, inaddition to the fins of the heat exchanger. Please contact Daikin for moreinformation.

RSNY8KTAL22.4kw(8HP)

Different capacity and different typeof indoor unit can be connected atthe capacity ratio of 50 to 100% ofthe outdoor unit, and up to 6 indoorunits can be connected withindividual control.

The individual control of the air conditioning system for 4–5 rooms can be realizedby more simple and lesser installation work.

Outdoor Unit

VRV K Series—Outdoor Units

Ceiling Mounted Cassette (Double flow)Ceiling Mounted Cassette (Multi flow) Super Cassette

FXC-LVE

Type Modelname

FXFL-LVECeiling Mounted Cassette Corner FXK-LVE

1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP 5 HP 8 HP

12300 15400 19100 24200 30700 38200 47800 765001.0 ton

31.25 40 50 62.5 80 100 125 200IndexHP

BtuRT 1.3 ton 1.6 ton 2.0 ton 2.6 ton 3.2 ton 4.0 ton 6.4 ton

Ceiling Mounted Built-in

Ceiling Suspended

Floor StandingConcealed Floor Standing

Ceiling Mounted DuctFXH-LVEFXA-LVE

FXS-LVE

FXL-LVEFXN-LVE

FXM-LVE

Wall Mounted

Ceiling Mounted Duct FXYD-KAVE

Cooling Only & Heat Pump

VE: 1 phase, 220-240/220 V, 50/60 HzPower supplyIndoor unitModel

Cooling capacity (1)/(2)RTBtu/h

31.25 40

1.1/1.012,600/12,300

1.113,600

3,200/3,100

3,400

50

1.3/1.316,000/15,400

1.417,100

4,000/3,900

4,300

62.5

1.6/1.619,800/19,100

1.821,500

5,000/4,800

5,400

2.1/2.024,900/24,200

2.327,300

6,300/6,100

6,900

80

2.6/2.631,700/30,700

2.834,100

8,000/7,700

8,600

100

3.3/3.239,600/38,200

3.642,700

10,000/9,600

10,800

125

4.1/4.049,500/47,800

4.554,600

12,500/12,000

13,800

200

6.5/6.4

kW 3.7/3.6 4.7/4.5 5.8/5.6 7.3/7.1 9.3/9.0 11.6/11.2 14.5/14.0 23.0/22.4

78,500/76,400

7.185,300

19,800/19,300

21,500Heating capacity

RT

4.0 5.0 6.3 8.0 10.0 12.5 16.0 25.0kW

Btu/h

kcal/h

kcal/h

Notes: Specifications are based on the following conditions;(1)Cooling : 27°CDB, 19.5°CWB, and outdoor temp. 35°CDB.(2)Cooling : 27°CDB, 19.0°CWB, and outdoor temp. 35°CDB.

• Heating : Indoor temp. of 20°CDB, of 7°CDB, 6°CWB.• Equivalent piping length : 7.5 m.• Level difference : 0 m.

2. Specifications are based on the following conditions;•Cooling: (*1) Indoor temp.: 27.0°CDB, 19.0°CWB, Outdoor temp.: 35.0°CDB

(*2) Indoor temp.: 29.0°CDB, 19.0°CWB, Outdoor temp.: 46.0°CDB•Heating: (*3) Indoor temp.: 20.0°CDB, Outdoor temp.: 7.0°CDB/6.0°CWB.

VAM150FAVE VAM250FAVE VAM350FAVE VAM500FAVE

58/64(58/66)

64/69(64/71)

58/62(58/63)

64/68(64/69)

61/67(61/68)

65/70(65/71)

58/63(58/65.5)

62/67(62/68.5)% For heating50 Hz (60 Hz)% For cooling50 Hz (60 Hz)

Model

Enthalpy exchangeefficiency (H/L)

74/79(74/80) 72/77(72/77) 75/80(75/81) 74/77(74/78.5)

VAM650FAVE VAM800FAVE VAM1000FAVE VAM1500FAVE

58/63(58/65)

63/66(63/68)

60/62(60/63)

65/67(65/68)

61/63(61/66)

66/68(66/71)

61/64(61/64)

66/68(66/68)

74/77(74/78) 74/76(74/76) 75/76.5(75/78) 75/78(75/78)

VAM2000FAVE

61/66(61/66)

66/70(66/70)

75/78(75/78)% 50 Hz (60 Hz)Temp. exchangeefficiency (H/L)

(50 Hz/60 Hz)

1 phase, 220-240 V/220 V, 50 Hz/60 HzPower supply150/150 250/250 350/350 500/500Ultra-High150/150 250/250 350/350 500/500High110/110 155/145 230/210 350/300Low

Air Flow Rate (m3/h)[50 Hz/60 Hz]

69/98 64/98 98/142 98/147Ultra-High39/54 39/54 70/85 54/54High20/24 20/20 25/15 25/20Low

External StaticPressure (Pa)[50 Hz/60 Hz]

650/650 800/800 1,000/1,000 1,500/1,500650/650 800/800 1,000/1,000 1,500/1,500500/440 670/660 870/800 1,200/1,20093/162 137/225 157/196 137/20639/69 98/118 98/108 98/11825/34 49/69 78/69 49/69

2,000/2,0002,000/2,0001,400/1,400137/19678/8859/69

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Capacity

Note:• Specifications for RT and Btu are based on the following conditions; Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.

Page 16: daikin Catalogs, Daikin Middle East

29 30

Individual Control Systems Centralized Control SystemsControl Systems Control Systems

Large liquid crystal screen displayscomplete operating status.Digital display lets you settemperature in 1°C units.Lets you individually program bytimer the respective times foroperation start and stop within amaximum of 72 hours.Equipped with a thermostat sensor inthe remote controller that makespossible more comfortable roomtemperature control.Enables you to select cool/heat/fanoperation mode with the indoorremote controller of your choicewithout using the cool/heat selector.

Constantly monitors malfunctions inthe system for 80 items, and isequipped with a "self-diagnosisfunction" that lets you know bymessage immediately when amalfunction occurs.Lets you carry out various fieldsettings by remote controller.

Wired remote controller (Optional)

Wired remote controller

The remote controller hascentralized its frequently usedoperation selectors andswitches (on/off, operationmode, temperature setting andairflow volume), making itselfsuitable for use in hotel roomsor conference rooms.

Signal receiver unit(Separate type)

Wireless remotecontroller

The concealed-type remote controller smartly fits into anight table or console panel in a hotel room.

Exposed type

Concealed type(For hotel use)

Wireless remote controller (Optional)

Simple remote controller (Optional)

The same operation modes and settings as with wired remote controllers arepossible.

• A light receiving unit for a ceiling-mounted cassette (double-flow, multi-flow) type,ceiling-suspended type and wall-mounted type is mounted into the indoor unit.

Signal receiver unit(Installed type)

Signal receiving unit can beinstalled on the panelex. Ceiling mounted cassette (multi-flow) type

Note : 1. Installation box for adaptor must be procured on site.

Central remote controller (Optional)64 groups (zones) of indoor units can becontrolled individually same as LCD Remote controller.Max.64 groups (128 indoor units controllable)Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers,which can control from 2 different places.Zone controlMalfunction code displayMax. wiring length 1,000 m (Total : 2,000 m)Combination with Unified ON/OFF controller, schedule timer and BMS systemAirflow volume and direction can be controlled individually for indoor units in each group operation.Ventilation volume and mode can be controlled for Heat Reclaim Ventilation (HRV).Up to 4 Operation/Stop pairs can be set per day by connecting a schedule timer.

Unified ON/OFF controller (Optional)16 groups of indoor units can be operatedsimultaneously/individually.Max. 16 groups (128 indoor units) controllable2 remote controllers can be used to control from 2 different places.Operating status indication (Normal operation, Alarm)Centralized control indicationMax. wiring length 1,000 m (Total : 2,000 m)Compact size casing (Thickness : 16 mm)Combination with Central Remote controller, Schedule timer and BMS system

Schedule timer (Optional)Max.128 indoor units can be operated asprogramed schedule.Max. 128 indoor units controllableWhen used in combination with a central remote controller, a maximum of 8 weekly schedulepatterns can be set, while the central controller can be used to select desired zones. Up to 4Operation/Stop pairs can be set per day.Max. 48 hours back up power supplyMax. wiring length 1,000 m (Total : 2,000 m)Compact size casing (Thickness : 16 mm)Combination with Central Remote controller, Unified ON/OFF controller and BMS system

Part name Model No. Function

Unification adaptor for computerized control DCS302A52

Interface between the central monitoring board and centralcontrol units. Combined with the central remote controller,this adaptor enables the central monitoring board tocentralize such functions as the on/off control, operationstatus monitoring, and normal/malfunction monitoring.(*1)

Interface adaptor for SkyAir series DTA102A52

Wiring adaptor for other air-conditioner DTA103A51

DTA107A55

Adaptors required to connect products other than those ofthe VRV System to the high-speed DIII-NETcommunication system adopted for the VRV System.

* To use any of the above optional controllers, an appropriate adaptor must beinstalled on the product unit to be controlled.

Central control adaptor kitFor UAT(Y)-K(A), FD-K

For SkyAir, FD(Y)M-FA, FDYB-KA, FDY-KAFVY(P)J-A, FXUQ-MH, FXLQ-MH

For air conditioners other than mentioned above.

DCS302C61

DCS301B61

DST301B61

Set back time clock (Optional)

Set back time clock

Connected to LCD wired remote controller(BRC type), this time clock can set 2 setsof on/off times in an increment of 30 minutes within a day. For each on/off setting atemperature setting is also possible.

Page 17: daikin Catalogs, Daikin Middle East

31 32

Daikin's advanced air-conditioning control systemsControl Systems

Contact signal

Ai unit

Light/Fan

Daikin CentralAir ConditioningSystem

Localmonitoring& control

WatchDOGRemoteMulti-PC

Ethernet

Remote PC Sub PC

SecurityFire alarm

D -NET

D -NET

D -NETD -NET

Wiring adaptor required for connection withother equipment not compatible with D -NET

DAM602A51/52/53*2

Viainternet

HRV

VRV System

Centralized control system for easy provision of effective control andmonitoring of VRV system functionsFloor visual navigationGraphical reportRemote intelligent managerMulti-PC accessWatch dog function for remote error monitoringPower limit controlSliding temperature <optional (DAM101A51) unit required>Automatic heat/cool change-overECO modeTemperature limitationAir Conditioning Network Service System (Optional Maintenance Service)

Ethernet

Local Controller

Please contact Daikin for compatibility with BMS system

SecurityPower supply facility

Fire alarm

ElevatorPumpLighting...etc

BMS

HRV

VRV System

Integrated control systems that recognize the trend of open control systems

*1Air ConditioningNetwork Service System(Optional Maintenance Service)

Compatibility with BMS enhanced by utilizing the international communication standards,BACnet® or LONWORKS®.

XIF file for confirming of specifications of the units.Connectable up to 10 outdoor units and 64 indoor unit groups.

Conformance class 3 (ASHRAE 135–1995)Standard BACnet® Device B-ASC (ASHRAE 135–2001)BACnet® OPC server compatibilityBACnet®/IP over EthernetUp to 40 outdoor units and 256 indoor uit groups on one gateway. (optional adapter)

DMS504B51 Interface for use in LONWORKS®

DMS502A51 Interface for use in BACnet®

NewNew

Dio unit

Interfacing requirements vary depending on model, and some systems may not be suitable. Please contact your distributor for details.

Local dealers

I/F unit*5Automatic data transfer

Mainfunction informationby E-mail

INTERNET

*1. There are restrictions in applicable areas and release times, therefore please consult us separately for details.*2. Model name varies upon the system size.*3. BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).*4. LONWORKS® is a registered trade mark of Echelon Corporation.*5. For an I/F unit, one of the following can be selected: L oc al C ontroller, intelligent touch Controller, or intelligent Manager II.*6. Ethernet is a registered trademark of Xerox Corporation.

ACC center

Maintenance services that boost profitsand customer satisfaction

Air ConditioningNetwork Service System

24 hour on-line diagnostic systemEnergy saving and extention of aircon operating lifeMaintenance management via A/C network service system reportsReliable service at shortest lead time

BACnet® LONWORKS®Interface for and

DMS502A51(Interface for use in BACnet®)

DMS504B51(Interface for use in LONWORKS®)

N e w F u n c t io n sN e w F u n c t io n s

• Features control and monitoring functions for centralA/C products and an Air Conditioning NetworkService function.

• Using an external contact via DIII-NET, monitors andcontrols equipment such as lighting, fans, orbuilding security systems.

NewNew

Color LCD touch panel icon displaySmall manageable sizeSimplified engineeringMulti language (English, French, Italian, German, Spanish and Chinese)Yearly scheduleP.P.D. (Power Proportinal Distribution function) (Optional)Auto heat/cool change-overTemperature limitationHistory of 500 actionsAir Conditioning Network Service System (Optional Maintenance Service)Simple Interlock Function

New communication functions in the user-friendly icon-based multilingualcontroller simplify centralized control of the VRV system.

Support for centralized control from elsewhereusing a PC with a Web browser (Optional)Sending of e-mail alerts to a specified addresswhen malfunctions occur (Optional)Built-in modem for connecting toAirnet Service System (Optional)

Built-in Ethernet port for connecting tothe Internet or an intranetManagement of facilities / equipmentother than A/C units(Compatible with Dio unit and Di unit)

Doubling of number of control pointsby adding a D -NET Plus Adapter (Optional)

ACC center• Air Conditioning Network Service System

Forced OFF from the fire alarm

Pi Port

• Connection to power consumptionmeter when using power proportionaldistribution function. (Optional)

DIII-NETPlus Adapter(option)

Number of indoor unit expanded from 64 to 128.

Indoor Unit

RS-232CControl pump,lighting

Monitoring of roomenter/exit sign

Simple Interlock Function

Public phone line

Air ConditioningNetwork Service Systemmodem for connections

• CSV output of powerproportional distributionresults (Optional)

PCMCIAFlashMemory

Mobile PhoneTrouble reports

Forced OFF contact input

HRV

Dio Unit

Di Unit

D -NET

NewFunction 6

NewFunction 1

Remote monitoring and control

NewFunction 5

NewFunction 3

NewFunction 2

NewFunction 4

NewFunction 6

NewFunction 1

NewFunction 3

NewFunction 5

NewFunction 3

NewFunction 2

NewFunction 4

NewFunction 6

NewFunction 7

NewFunction 7

NewFunction 1

NewFunction 3

NewFunction 5

NewFunction 3

NewFunction 2

NewFunction 4

NewFunction 1New

Function 1

NewFunction 2New

Function 2

NewFunction 3New

Function 3

NewFunction 4New

Function 4

NewFunction 5New

Function 5

NewFunction 6New

Function 6

NewFunction 7New

Function 7 Simple Interlock Function

N e w F u n c t io n sN e w F u n c t io n s

Trouble reports

DCS601C51

Unification adaptorfor computerized control

[DCS302A52]

Unified ON/OFF andstatus monitoring fromthe central monitoring panel

Upgrade

Upgrade

NewNew

Page 18: daikin Catalogs, Daikin Middle East

Note: Availability of the products shown in this catalogue varies by country.

Note: •Specifications for RT, Btu and kW are based on the following conditions; Power supply: 60 Hz; Cooling: Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•The values given for 2 HP to 3 HP are for the FDB model, 4 HP to 6 HP are for the FDM model and 8 HP to 20 HP are for the FD model.The values given for 30 HP are for the UAT model and based on the following conditions; Power supply: 50 Hz; Cooling: Indoor temp. of 27°C DB, 19.5°C WB, and outdoor temp. of 35.0°C DB.

33 34

Daikin’s duct connection type packaged air conditioners are the best choicefor stores and offices. By placing the air conditioner in the ceiling, the designand finish of all areas remain attractive and unblemished. With minimaloperating sound, people nearby are almost unaware of the unit’s presence.And simultaneous operation of 2 to 4 indoor units with a single outdoor unit ispossible. When indoor units are distributed taking sunlight and humanoccupation patterns into consideration, a comfortable air flow is effectivelyspread throughout the room.Air cooled packaged water chillers are also available.Such systems can easily meet all the air-conditioning requirements offactories and other large areas.

Air Cooled Packaged Air ConditionersDuct Connection Series....................................... 35Air Cooled Single Packaged Air Conditioners......41Air Cooled Packaged Water Chillers....................42

Line Up

Packaged air conditioners

PACKAGEDAIR CONDITIONERS

Type Model Name

Air cooledpackagedduct connectionseriesLow staticpressure type

5.6 6.5 8.1 11.4 14.3 15.8 24.0 29.2 47.9 58.4kW 97.1HP 2 2.5 3 4 5 6 8 10 15 20 30

19100 22200 27600 38900 48800 53900 81900 99600 163400 199300Btu 331000RT 1.6 1.8 2.3 3.2 4.1 4.5 6.8 8.3 13.6 16.6 27.5

C/O60 Hz

50 HzFDBG

FDB

FDMG

FD(Y)M

H/P60 Hz

50 HzFDYB

FD

FDY

Air cooledpackagedduct connectionseriesMiddle staticpressure type

C/O60 Hz

50 Hz

FDM H/P60 Hz

50 Hz

Air cooledpackagedduct connectionseriesHigh staticpressure type

C/O60 Hz

50 Hz

H/P60 Hz

50 Hz

UAT

UATY

Air cooledsingle packagedair conditionersRoof top type

C/O

C/O

50 Hz60 Hz

H/P 50 Hz60 Hz

Simultaneousoperationsystem

UWAAir cooledpackagedwater chillers 60 Hz

50 Hz

50 100 150 200 250 300 400 500 600 700kW 800

PACKAGEDAIR CONDITIONERS

WATER CHILLERS

Capacity

Type Model Name HP 2 2.5 3 4 5 6 7.5 10 15 20 30

Page 19: daikin Catalogs, Daikin Middle East

Operation range(Outdoor temp.)

Operation range(Outdoor temp.)

35 36

Duct Connection Series Low Static Pressure Type

PACKAGEDAIR CONDITIONERS

Air Cooled Packaged Air Conditioners—FD(Y)B(G) Series Air Cooled Packaged Air Conditioners—FD(Y)M Series

Duct Connection Series Low Static Pressure TypePerfect for quiet, beautiful, living spaceslike condominiums and apartments,houses and hotels, and similar living areas

R emote C ontroller Outdoor Unit

Whisper QuietIndoor unit with the industry's lowest level of sound

HandySmall, lightweight and easy-to-install outdoor unit

DurableThe special acryl precoated fin (PE fin) for anti-corrosiontreatment on the outdoor unit heat exchanger ensuresgreater resistance against salt damage and atmosphericpollution than ever.

Easy to UseEasy to read LCD wired remote controller (Optionalaccessory for heat pump type) (FDYB only)

Duct Connection Series Middle Static Pressure TypeDuct Connection Series Middle Static Pressure TypeMain unit can be mountedin the ceiling, and air can bedelivered freely by duct.

DurableThe special acryl precoated fin (PE fin)for anti-corrosion treatment on theoutdoor unit heat exchanger ensuresgreater resistance against salt damageand atmospheric pollution than ever.

Easy to UseEasy to read LCD wired remotecontroller. (Optional accessory)(FDYM only)

Central controlMany options are available for use withlarge-scale and advanced-functioncentrally controlled systems.(FDYM only)

FDBG50AVEFDB50KVE

FDBG60/71AVEFDB60/71KVE

FDYB50KAVE FDYB60/71KAVE

Digital RemoteController

LCD WiredRemoteController (Only for Heat Pump)

RemoteController

For Cooling Only Type For Heat Pump Type

SignalReceiverUnit

Wireless Remote Controller

Cooling Only (50 Hz)

Cooling Only (60 Hz) Heat Pump (60 Hz)

Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

• Shows net capacities. When cooling it is the value minus the heat of the indoor unit fan motor. When heating, the heat of the fan motor is added.

ModelIndoor unit

Btu/hkcal/hkW

Cooling capacity*1 (1)/(2)

Outdoor unit

Power Supply VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz

R50GV1

FDBG50AVE50

R60GV1K

FDBG60AVE60

FDBG71AVER71FUV1R71FUY1

71

18,200/18,1004,590/4,5605.34/5.30

24,000/23,8006,050/6,0007.03/6.97

26,600/26,3006,700/6,6007.80/7.70

°CDB

kWCOP *1 (1)/(2)Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)2.59/2.592.06/2.05

2.55/2.5319.4 to 54

2.76/2.752.77/2.7521 to 52

2.82/2.8

°CDB

kWCOP *1 (1)/(2)Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)

°CDB

kWCOP *1 (2)Operation range (Outdoor temp.)

Power comsumption *1 (2)/(3)

2.79/2.783.15/3.13

2.60/2.604.08/4.04

2.68/2.6621 to 52

4.89/4.85

kWkWPower comsumption

2.00/2.022.64

2.20/2.502.44/2.502.37

2.70/3.303.30/3.302.31

3.50/4.20

°CDB°CWB

Heating*2 (1)/(2)Cooling*1 (2)/(3)

CoolingHeating

COP

19.4 to 54-10 to 15

3.15 2.95-5 to 54-10 to 15.5

2.73kWkWPower comsumption

°CDB°CWB

Heating*2 (1)/(2)Cooling*1 (2)/(3)

CoolingHeating

COP

-10 to 15.5-5 to 54

-10 to 15

RT 1.5/1.5 2.0/2.0 2.2/2.2

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz

FDB50KVE FDB60KVE FDB71KVER50GVAL R60GVAL R71FUVAL

19,100/17,1004,820/4,3005.60/5.0

22,200/19,1005,590/4,8006.50/5.6

27,600/22,9007,000/5,8008.10/6.7

1.6/1.4 1.8/1.6 2.3/1.9

———

———

———

— — —

2.67—

—2.41—

—2.45—

—19.4 to 54

—21 to 54—

—2.10/2.41 2.70/3.29 3.30/3.78

50 60 71

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz

FDYB50KAVE FDYB60KAVE FDYB71KAVERY50GVAL RY60GVAL RY71FUVAL

19,800/17,4004,990/4,3905.80/5.11

21,800/19,5005,500/4,9106.40/5.71

27,600/24,6007,000/6,2008.10/7.20

50 60 71

Model

Btu/hkcal/hkW

1.6/1.5 1.8/1.6 2.3/2.0RTCooling capacity*1 (2)/(3)

21,500/21,3005,420/5,3706.30/6.25

24,500/24,3006,180/6,1407.19/7.13

30,700/30,7007,700/7,7009.00/9.00

Btu/hkcal/hkW

1.8/1.8 2.0/2.0 2.6/2.6RTHeating capacity*2 (1)/(2)

Power SupplyOutdoor unitIndoor unit

FD(Y)M03FAVAL FD(Y)M04FAVALFDYM05/06FAVAL

LCD wiredremotecontroller

SignalReceiverUnit

Wireless RemoteController

Cooling Only (50 Hz)

V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz

FDMG71AV1 FDMG100AV1 FDMG125AV1R100FUV1

8.80/8.7 10.6/10.5 13.1/12.9

71 100 125

R100FUY1R71AV1R71AY1

R125FUV1ModelIndoor unit

30,000/29,7007,600/7,500

36,200/35,8009,100/9,000

44,700/44,00011,200/11,000

Btu/hkcal/hkW

2.5/2.5 3.0/3.0 3.7/3.7RTCooling capacity*1 (1)/(2)

Outdoor unit

Power Supply

Cooling Only (60 Hz)

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 HzR71FUVALFDM03FAVAL

71

R100FUVALFDM04FAVAL

100

R125FUTALFDM05FAVAL

125FDYM06FAVALR140KUTALK

140

8.10/6.7 11.40/9.0 14.3/12.5 15.8/14.03.44/3.92 4.61/5.27 6.25/7.102.35 2.47 2.29 2.72

21 to 54

5.80/7.00

ModelIndoor unit

27,600/22,900 38,900/30,700 48,800/42,7007,000/5,800 9,800/7,700 12,300/10,800

53,900/47,80013,500/12,000

Btu/hkcal/hkW

2.3/1.9 3.2/2.6 4.1/3.6 4.5/4.0RTCooling capacity*1 (2)/(3)

Outdoor unitPower Supply

ModelIndoor unit

8.1/6.7 11.4/9.0 14.3/12.5 15.8/14.0

27,600/22,9007,000/5,800

38,900/30,7009,800/7,700

48,800/42,70012,300/10,800

53,900/47,80013,500/12,000

Btu/hkcal/hkW

2.3/1.9 3.2/2.6 4.1/3.6 4.5/4.0RTCooling capacity*1 (2)/(3)

9.00/8.50 12.80/11.80 16.20/15.00 18.10/17.00

30,700/29,0007,700/7,300

43,700/40,30011,000/10,100

55,300/51,20013,900/12,900

61,800/58,00015,600/14,600

Btu/hkcal/hkW

2.6/2.4 3.6/3.4 4.6/4.3 5.1/4.8

2.122.52

3.57/3.592.392.85

4.49/4.512.362.91

5.56/5.602.723.12

5.80/5.903.82/4.37 4.76/5.25 6.05/6.71 5.80/7.00

RT

Heat Pump (60 Hz)

RY140KUTALKRY100FUVALRY71FUVAL RY125FUTALOutdoor unit

Heating capacity*2(1)/(2)

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 HzPower Supply

FDYM03FAVAL FDYM04FAVAL FDYM05FAVAL FDYM06FAVAL71 100 125 140

Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

•*2:Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

• Shows net capacities. When cooling it is the value minus the heat of the indoor unit fan motor. When heating, the heat of the fan motor is added.• For FDMG models, capacities show gross capacities which do not include a deduction for evaporator fan motor heat.

R emote C ontroller Outdoor Unit

Cooling*1 (2)Heating *2 (1)

Cooling *1 (2)Heating *2 (1)

FDMG71AV1 FDMG100/125AV1

Digital RemoteController

RemoteController

For FD(Y)M modelsFor FDMG models

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284 Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Page 20: daikin Catalogs, Daikin Middle East

37 38

PACKAGEDAIR CONDITIONERS

Air Cooled Packaged Air Conditioners—FD(Y) Series

Duct Connection Series High Static Pressure TypeDuct Connection Series High Static Pressure TypeRecommended for spacious and large-volume areas because ofits flexible installation. Suitable for large stores, factories, andother large areas, and for use with housing ducts in homes.

Highly Adaptable InstallationHigh static pressure and long piping enable flexibleinstallation and use wherever the unit is placed.

CompactSpace-saving outdoor unit also enables lateralconnection.

DurableHighly durable outdoor unit employs PE fins, resistssalt damage and atmospheric pollution.

Super QuietIndoor unit with the industry's lowest level of sound.

Central controlMany options are available for use with large-scaleand advanced-function centrally controlledsystems.

FD03KY1FD03KVAL

FD04KY1FD04KVAL

FD05KY1FD05KTAL

FD(Y)10K(A)Y1FD(Y)10K(A)TAL·YAL

FD(Y)15KAY1FD(Y)15KATAL·YAL

FD06KY1FD06KTAL

FD(Y)08K(A)Y1FD(Y)08K(A)TAL·YAL

FD(Y)20KAY1FD(Y)20KATAL·YAL

RemoteController

(Only for Cooling Only)

LCD wiredremote controller

(Only for Heat Pump)(Only for Heat Pump)

SignalReceiverUnit

Wireless Remote Controller

FD03KY1R71FUY1

FD04KY1R100FUY1

FD05KY1R125FUY1

FD06KY1RU06KY1

ModelIndoor unitOutdoor unit

8.1/7.9 11.0/10.8 14.0/13.8 17.4/17.2

FD08KY1RU08K(U)Y1

24.3/24.0

FD10KY1RU10K(U)Y1

FD15KY1RU08K(U)Y1X2

29.7/29.2 48.6/47.9

FD20KY171 100 125 140 200 250 400 500

RU10K(U)Y1X2

59.3/58.4

3.24/3.19 3.13/3.10 3.34/3.33 3.05/3.022.5/2.48 3.52/3.48 4.19/4.15 5.7/5.7

3.24/3.247.5/7.4

3.00/2.98 3.24/3.249.9/9.8 15.0/14.8

2.99/2.9821 to 52

19.8/19.6

27,600/27,0007,000/6,800

37,500/36,8009,500/9,300

47,800/47,10012,000/11,800

59,400/58,70015,000/14,800

82,900/81,90020,900/20,600

101,300/99,60025,500/25,100

165,800/163,40041,800/41,200

202,300/199,30051,000/50,200

Btu/hkcal/hkW

2.3/2.2 3.1/3.1 4.0/3.9 4.9/4.9 6.9/6.8 8.4/8.3 13.8/13.6 16.8/16.6RTCooling capacity*1 (1)/(2)

Cooling Only (50 Hz)

Y1: 3 phase, 380-415 V, 50 HzPower Supply

71 100 125 140 200 250 400 500FD03KVALR71FUVAL

FD04KVALR100FUVAL

FD05KTALR125FUTAL

FD06KTALRU06KTAL

8.5/7.1 11.9/9.0 15.2/14.1 17.3/15.7

FD08KTALRU08K(U)TAL

24.0/21.9

FD10KTALRU10K(U)TAL

FD15KTALRU08K(U)TALX2

29.2/26.7 47.9/43.8

FD20KTALRU10K(U)TALX2

58.4/53.3

2.6421 to 542.72 2.59 2.66

3.22/3.70 4.37/5.02 5.88/6.73 6.50/7.902.89

8.30/10.102.83 2.89

10.30/12.60 16.60/20.202.83

20.60/25.30

ModelIndoor unitOutdoor unit

29,000/24,2007,300/6,100

40,600/30,70010,200/7,700

51,900/48,10013,100/12,100

59,000/53,60014,900/13,500

81,900/74,70020,600/18,800

99,600/91,10025,100/23,000

163,400/149,40041,200/37,700

199,300/181,90050,200/45,800

Btu/hkcal/hkW

2.4/2.0 3.4/2.6 4.3/4.0 4.9/4.5 6.8/6.2 8.3/7.6 13.6/12.4 16.6/15.1RTCooling capacity*1 (2)/(3)

Cooling Only (60 Hz)

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 HzPower Supply

kW

Cooling capacity*1 (2)/(3)

23.2/22.9 29.5/29.1 44.8/44.6 56.8/56.6

22.2/19.8 27.1/24.3 43.5/38.7

Btu/hkcal/h

75,700/67,60019,100/17,000

92,500/82,90023,300/20,900

148,400/132,00037,400/33,300

180,800/161,40045,600/40,70053.0/47.3

RT 6.3/5.6 7.7/6.9 12.4/11.0 15.1/13.4

79,200/78,10020,000/19,700

100,700/99,30025,400/25,000

152,900/152,20038,500/38,400

193,800/193,10048,800/48,700

Btu/hkcal/hkW

6.6/6.5 8.4/8.3 12.7/12.7 16.1/16.1RTHeating capacity*2(1)/(2)

TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 HzPower Supply

ModelIndoor unit

RY250KUTALX2RY250KUYALX2

Outdoor unit

200 250 400 500

RY200KUTALX2RY200KUYALX2

RY250KUTALRY250KUYAL

RY200KUTALRY200KUYAL

FDY20KATALFDY20KAYAL

FDY15KATALFDY15KAYAL

FDY10KATALFDY10KAYAL

FDY08KATALFDY08KAYAL

Heat Pump (60 Hz)

kW

Cooling capacity*1 (1)/(2)

79,20020,000

100,70025,400

153,00038,500

194,00048,800

22.5/22.2 27.6/27.1 44.0/43.5

79,20020,000

100,70025,400

152,90038,500

193,80048,800

Btu/hkcal/h

76,800/75,70019,300/19,100

94,200/92,50023,700/23,300

150,000/148,00037,800/37,400

184,000/181,00046,400/45,600

76,800/75,70019,300/19,100

94,200/92,50023,700/23,300

150,100/148,40037,800/37,400

183,900/180,800RT 76,800/75,700 94,200/92,500 150,000/148,000 184,000/181,0006.4/6.3 7.8/7.7 12.5/12.4 15.3/15.1

46,400/45,60053.9/53.0

23.2 29.5 44.8 56.8

76,800/75,70019,300/19,100

94,200/92,50023,700/23,300

150,000/148,0007.2/7.1 9.3/9.2 14.4/14.2

37,800/37,400184,000/181,00046,400/45,600

3.8 3.35 3.67 3.23

6.13.13/3.13

8.82.97/2.95

12.23.06/3.06

17.62.91/2.90

18.5/18.3

Btu/hkcal/h

23.2 29.5 44.8 56.823.2 29.5 44.8 56.8kW

23.2 29.5 44.8 56.86.6 8.4 12.7 16.1RTHeating capacity*2(1)

Y1: 3 phase, 380-415 V (4 wires), 50 HzPower Supply

ModelRY250KUY1X2

200 250 400 500

RY200KUY1X2RY250KUY1FDY20KAY1FDY15KAY1FDY10KAY1

Heat Pump (50 Hz)

Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Outdoor unitFDY08KAY1RY200KUY1

Indoor unit

R emote C ontroller Outdoor Unit

°CDB

kWCOP *1 (1)/(2)

Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)

°CDB

kWCOP *1 (2)Operation range (Outdoor temp.)

Power comsumption *1 (2)/(3)

kWkWPower comsumption

Heating*2 (1)Cooling*1 (2)/(3)

COP Cooling*1 (1)/(2)Heating *2 (1)/(2)

0 to 54-10 to 15

7.7/9.4 9.7/11.9 15.3/18.8

3.52 3.17 3.39 3.05

6.6/6.72.88

9.3/9.52.79

13.2/13.42.84

18.6/19.02.73

19.4/23.8

Operation range(Outdoor temp.)

CoolingHeating

kWkWPower comsumption

°CDB°CWB

Heating*2 (1)/(2)Cooling*1 (2)/(3)

COP Cooling*1 (2)Heating *2 (1)

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Page 21: daikin Catalogs, Daikin Middle East

39 40

PACKAGEDAIR CONDITIONERS

Simultaneous Operation System—Twin, Triple & Double Twin Multi Application Operation

In large interior spaces a single indoor unit may not be able to provide uniform comfort. Installation of 2 to 4 units, distributed toconsider sun light and human gathering patterns, can provide an effective solution.

In a single-floor restaurant, for example, positioning 4 units at strategic locations achieves comfortable air flow that reachesevery inch of the room.

Simultaneously operates 2 to 4 indoor units usinga single outdoor unit.

Installing multiple units is economical and ensures comfort

Lower cost of installation than for individual pair typeLess space needed for outdoor unitsEnhanced comfort from distributed indoor units

Note: This type of system does not allow individual control or independent operation of indoor units. It is not the best choice for large rooms with partitions.

Branch piping kit Branch piping kitBranch piping kit

Branch piping kit

ModelIndoor unit FDYM04FAV1X2Outdoor unit R200KUY1

76,800/75,70019,400/19,10022.5/22.2

FDYM05FAV1X2R250KUY1

92,500/90,80023,300/22,90027.1/26.6

FDYM03FAV1X3200 250 200

R200KUY1

76,800/75,70019,400/19,10022.5/22.2

7.7/7.62.92/2.92

9.9/9.92.74/2.69

8.0/7.92.81/2.81

-5 to 52

Btu/hkcal/hkW

6.4/6.3 7.7/7.6 6.4/6.3RTCooling capacity*1(1)/(2)

Cooling Only (50 Hz)

V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 HzPower Supply

ModelIndoor unit FDYM04FAVALX2

Outdoor unitR200KUTAL

75,700/68,20019,100/17,20022.0/20.0

FDYM05FAVALX2R250KUTAL

90,800/82,20022,900/20,70026.6/24.1

FDYM03FAVALX3200 250 200

R200KUTALR200KUYAL R250KUYAL R200KUYAL

75,700/68,20019,100/17,20022.2/20.0

2.718.2/10.0

2.5610.4/12.7

2.61-5 to 54

8.5/10.3

Btu/hkcal/hkW

6.3/5.7 7.6/6.8 6.3/5.7RTCooling capacity*1(2)/(3)

Cooling Only (60 Hz)

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 HzPower Supply

ModelIndoor unitOutdoor unit

Btu/hkcal/hkW

RTCooling capacity*1(2)/(3)

Btu/hkcal/hkW

75,700/68,20019,100/17,200

90,800/82,20022,900/20,700

75,700/68,20019,100/17,200

22.2/20.0 26.6/24.1 22.2/20.0

6.3/5.7 7.6/6.8 6.3/5.7

77,500/76,40019,500/19,30022.7/22.4

96,900/95,50024,400/24,10028.4/28.0

77,500/76,40019,500/19,30022.7/22.4

7.0/7.12.71

8.2/10.09.7/10.02.61

10.2/12.67.0/7.12.71

8.20/10.00

3.24 2.930 to 54-10 to 15

3.24

6.4/6.4 8.1/8.0 6.4/6.4

75,700/68,20019,100/17,200

90,800/82,20022,900/20,700

75,700/68,20019,100/17,200

22.2/20.0 26.6/24.1 22.2/20.0

6.3/5.7 7.6/6.8 6.3/5.7

77,500/76,40019,500/19,30022.7/22.4

96,900/95,50024,400/24,10028.4/28.0

77,500/76,40019,500/19,30022.7/22.4

7.0/7.12.71

8.2/10.09.9/10.12.56

10.4/12.57.3/7.42.61

8.5/10.3

3.24 2.870 to 54-10 to 15

3.11

6.4/6.4 8.1/8.0 6.4/6.4

RTHeating capacity*2(1)/(2)

Heat Pump (60 Hz)

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 HzPower SupplyRY200KUTAL·YAL RY250KUTAL·YAL RY200KUTAL·YALFDYB50KAVEX4 FDYB60KAVEX4 FDYB71KAVEX3

200 250 200

Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

°CDB

kWCOP *1 (1)/(2)Operation range (Outdoor temp.)

Power comsumption *1 (1)/(2)Operation range(Outdoor temp.)

CoolingHeating

kWkWPower comsumption

°CDB°CWB

Heating*2 (1)/(2)Cooling*1 (2)/(3)

COP Cooling*1 (2)Heating *2 (1)

ModelIndoor unitOutdoor unit

Btu/hkcal/hkW

RTCooling capacity*1(2)/(3)

Btu/hkcal/hkW

RTHeating capacity*2(1)/(2)

Heat Pump (60 Hz)

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 HzPower SupplyRY200KUTAL·YAL RY250KUTAL·YAL RY200KUTAL·YALFDYM04FAVALX2 FDYM05FAVALX2 FDYM03FAVALX3

200 250 200

Operation range(Outdoor temp.)

CoolingHeating

kWkWPower comsumption

°CDB°CWB

Heating*2 (1)/(2)Cooling*1 (2)/(3)

COP Cooling*1 (2)Heating *2 (1)

°CDB

kWCOP *1 (2)Operation range (Outdoor temp.)

Power comsumption *1 (2)/(3)

76,800/75,70019,400/19,100

6.4/6.376,800/75,70019,400/19,100

6.4/6.392,500/90,80023,300/22,900

7.7/7.6Btu/hkcal/h

RT

22.5/22.2 22.5/22.2 27.1/26.6kW

Cooling capacity*1(1)/(2)

77,50019,500

6.477,50019,500

6.496,90024,400

8.1

6.52.92/2.92

7.7/7.66.5

2.92/2.92

7.7/7.69.2

2.79/2.74

9.7/9.7

3.49 3.49 3.09

Btu/hkcal/h

RT

22.7 22.7 28.4kW

Heating capacity*2(1)

ModelIndoor unit FDYB50KAVEX4Outdoor unit RY200KUY1

FDYB71KAVEX3RY200KUY1

FDYB60KAVEX4RY250KUY1

Heat Pump (50 Hz)

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 HzPower Supply

kWkWPower comsumption

Heating*2 (1)Cooling*1 (1)/(2)

COP Cooling*1 (1)/(2)Heating *2 (1)

76,800/75,70019,400/19,100

6.4/6.376,800/75,70019,400/19,100

6.4/6.392,500/90,80023,300/22,900

7.7/7.6Btu/hkcal/h

RT

22.5/22.2 22.5/22.227.1/26.6kW

Cooling capacity*1(1)/(2)

77,50019,500

6.477.50019,500

6.496,90024,400

8.1

6.52.92/2.92

7.7/7.66.8

2.81/2.81

8.0/7.99.4

2.69/2.74

9.9/9.9

3.49 3.343.02

Btu/hkcal/h

RT

22.7 22.728.4kW

Heating capacity*2(1)

ModelIndoor unit FDYM04FAV1X2Outdoor unit RY200KUY1

FDYM05FAV1X2RY250KUY1

FDYM03FAV1X3RY200KUY1

Heat Pump (50 Hz)

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 HzPower Supply

kWkWPower comsumption

Heating*2 (1)Cooling*1 (1)/(2)

COP Cooling*1 (1)/(2)Heating *2 (1)

Twin Multi Application Triple Multi Application Double Twin Multi Application

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Conversion rates

kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284

Page 22: daikin Catalogs, Daikin Middle East

41 42

PACKAGEDAIR CONDITIONERS WATER CHILLERS

Air Cooled Single Packaged Air Conditioners—UAT(Y) Series Air Cooled Packaged Water Chillers—UWA Series

Model

kcal/hCooling capacity *1(50/60 Hz)

Btu/h

Cooling capacity *2(50/60 Hz)

Btu/h

Model

Cooling capacity *1(50/60 Hz)

UATY06KY1UATY06KTALUATY06KYAL

UATY08KY1UATY08KTALUATY08KYAL

UATY09KY1UATY09KTALUATY09KYAL

UATY10KY1(50 Hz Only)

UATY12KTALUATY12KYAL(60 Hz Only)

UATY15KY1UATY15KTALUATY15KYAL

Heating capacity *3(50/60 Hz)

Cooling capacity *2(50/60 Hz)

52,900 67,600 81,200 96,600 107,800 135,200

UATY18KY1UATY18KTALUATY18KYAL

UATY21KY1UATY21KTALUATY21KYAL

17.7 22.0 26.4 31.4 35.1 43.9kW 52.7 61.6

5 6 7.5 9 10 12.5RT 15 17.5

kcal/h60,300 75,000 90,000 107,200 120,000 150,00015,200 18,900 22,700 27,000 30,200 37,800

Btu/h 180,000 210,40045,300 53,000

18.1 23.0 26.9 32.1 36.1 46.1kW 54.2 62.8kcal/h

62,000 78,600 91,700 109,600 123,000 157,20015,600 19,800 23,100 27,600 31,000 39,600

Btu/h 185,000 214,40046,600 54,000

EER *3(Cooling)

5.8 6.3 8.2 9.9 — 13.0 17.1 19.8

YAL8.26 9.74 9.18 — 8.86 9.528.28 9.78 9.21 — 8.94 9.52

TAL 8.64 8.988.64 9.00

162,100 189,40015.5 19.8 23.8 28.3 31.6 39.6 47.5 55.5kW

Btu/h

Heat Pump (50 Hz/60 Hz)

UAT06KAUATY06K

UAT08·09·10·12KAUATY08·09·10·12K

UAT15·18·21KAUATY15·18·21K

UAT30H

52,900 67,600 81,200 107,800 135,200

15,200 18,900 22,700 30,200 37,80060,300 75,000 90,000 120,000 150,000

UAT06KAY1UAT06KATALUAT06KAYAL

UAT08KAY1UAT08KATALUAT08KAYAL

UAT09KAY1UAT09KATALUAT09KAYAL

UAT12KATALUAT12KAYAL(60 Hz Only)

UAT15KAY1UAT15KATALUAT15KAYAL

162,100

45,300180,000

UAT18KAY1UAT18KATALUAT18KAYAL

189,400

53,000210,400

UAT21KAY1UAT21KATALUAT21KAYAL

96,600

27,000107,200

UAT10KAY1(50 Hz Only)

284,000/330,700kW 15.5 19.8 23.8 31.6 39.6 47.5 55.528.3 83.1/96.9

EER *3(Cooling)

TAL 8.26 9.74 9.18 8.86 9.52 8.64 8.98— —YAL 8.28 9.78 9.21 8.94 9.52 8.64 9.00— —

83,500/92,600331,000/368,000

kW 17.7 22.0 26.4 35.1 43.9 52.7 61.631.4 97.1/107.7

RT 5 6 7.5 10 12.5 15 17.59 27.5/30

UAT30HY1UAT30HTO

Digital Remote Controller Remote Controller(Only for Cooling Only)

Cooling Only (50 Hz/60 Hz)

Notes: 1. The above data marked with *1 are rated in accordance with JIS C-9612. 27°CDB (80°FDB)/ 19.5°CWB (67°FWB) indoor temp. And 35°CDB (95°FDB) outdoor temp.2. The above data marked with *2 are rated in accordance with SSA-385/386, 29°CDB (84°FDB)/ 19°CWB (66°FWB) indoor temp. And 46°CDB (115°FDB) outdoor temp.3. The figures of *2 are reference value.4. Capacity (*1, 2) is gross capacity which does not include a deduction for evaporator fan motor heat.5. *3: EER conditions: 27°CDB (80°FDB) and 19.5°CWB (67°FWB) for indoor temp. 35°CDB (95°FDB) for outdoor temp.

Notes: 1. Cooling capacities marked with *1 are based on 27°CDB (80°FDB) 19.5°CWB (67°FWB) indoor temp. and 35°CDB (95°FDB) outdoor temp.2. Cooling capacities marked with *2 are based on 29°CDB (84°FDB) 19.0°CWB (66°FWB) indoor temp. and 46°CDB (115°FDB) outdoor temp.3. Heating capacities are based on 21°CDB for indoor temp. 7°CDB/6°CWB for outdoor temp.4. The figures of *2 is reference value.5. *3: EER Cooling conditions: 27°CDB (80°FDB) and 19.5°CWB (67°FWB) for indoor temp. 35°CDB (95°FDB) for outdoor temp.6. *4: EER Heating conditions: 20°CDB for indoor temp. 7°CDB/6°CWB for outdoor temp.

Y1: 3 phase, 380-415 V, 50 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz/TO: 3 phase, 200/200-220 V, 50/60 HzPower Supply

Y1: 3 phase, 380-415 V, 50 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 HzPower Supply

UWA80JATJUWA138JY1UWA55JAY1

Model

USRTCooling capacity *1

UWA37JAY1 UWA47JAY1 UWA55JAY1 UWA63JAY1

369,800 468,200 550,400 634,900108.4 137.2 161.3 186.0

30.8 39.0 45.8 52.9

kWBtu/h

USRTCooling capacity *2 332,500 425,800 511,500 571,400

97.4 124.8 149.9 167.4

27.7 35.4 42.6 47.6

kWBtu/h

Model

USRTCooling capacity *1

UWA27JATJ UWA32JATJ UWA43JATJ UWA53JATJ

269,800 320,600 426,600 553,50079.0 94.3 125.0 162.0

UWA62JATJ

632,100185.0

22.4 26.7 35.5 46.1 52.6

kWBtu/h

USRTCooling capacity *2 242,000 280,900 378,900 494,000

71.0 82.0 111.0 145.0584,100171.0

20.1 23.4 31.5 41.0 48.6

kWBtu/h

Cooling Only (60 Hz)

Model

USRTCooling capacity *1

UWA120JY1 UWA138JY1 UWA162JY1 UWA192JY1

1,201,500 1,380,800 1,620,600 1,921,500351.6 404.4 474.7 562.8

UWA228JY1 UWA270JY1

2,280,400 2,700,800667.9 791.0

99.9 115.0 135.0 160.0 189.9 224.7

kWBtu/h

Cooling Only (50 Hz)

Cooling Only (50 Hz)

3 phase, 380-415 V, 50 HzPower supply

Model

USRTCooling capacity *1

UWA75JAY1 UWA80JAY1

747,600 855,100219.1 250.6

62.3 71.2

kWBtu/h

USRTCooling capacity *2 672,600 769,400

197.1 225.5

56.0 64.1

UWA93JAY1 UWA109JAY1

930,500 1,089,200272.7 319.2

77.5 90.7

855,900 991,200250.8 290.5

71.3 82.6

kWBtu/h

3 phase, 380-415 V, 50 HzPower supply

3 phase, 380-415 V, 50 HzPower supply

*1 Cooling capacity is based on the following conditions: Leaving chilled water temp. 6.7°C (44°F), entering water temp. 12.2°C (54°F) outdoor temp. 35°C (95°FDB).*2 Cooling capacity is based on the following conditions: Leaving chilled water temp. 6.7°C (44°F), entering water temp. 12.2°C (54°F) outdoor temp. 46.0°C (115°FDB).

Notes :

3 phase, 208-230 V, 60 HzPower supply

Model

USRTCooling capacity *1

UWA70JATJ

722,200212.0

60.0

kWBtu/h

USRTCooling capacity *2 653,100

191.0

54.2

UWA80JATJ UWA90JATJ

865,000 936,400253.0 274.0

72.0 78.0

746,400 845,200219.0 248.0

62.1 70.4

UWA108JATJ UWA122JATJ

1,107,000 1,262,000324.0 370.0

92.2 105.0

972,200 1,145,000285.0 335.0

81.0 95.3

kWBtu/h

3 phase, 208-230 V, 60 HzPower supply

R emote C ontroller

Roof Top TypeRoof Top TypeEasy to install on rooftop or veranda, requiring only ducting,power line and drain piping.In addition to its high efficiency, the scroll compressor is 10%lighter and 30% more compact than conventionalreciprocating compressors. This makes this series among theindustry's most lightweight and compact than previous models.Also, since the scroll compressor generates less vibration, thisseries has greatly improved its durability and achieved theindustry's lowest operation sound. (UAT(Y)-K Series)Efficient cross fin coils are used: the unique waffle louverfins*1 maximize heat exchange efficiency, while the Hi-XAcopper tube*2, featuring an inner spiral groove, fully exploitsrefrigerant turbulence to help increase heat exchangeefficiency. The result is substantial energy savings.U.S. PAT. *1; No.4,434,844 *2; No.4,480,684

Wide Operation Range:Operative high outdoor temperature.UWA37JAY1–109JAY1: 5 to 52°CUWA27JATJ, 37JATJ: 15 to 49°CUWA43JATJ–122JATJ: 5 to 49°CUWA120JY1–270JY1: 5 to 49°C

Equipped with a compact andpowerful semi-hermetically sealedreciprocating compressor.

Energy saving.

Capacity can be controlled in multiple steps from 3 to 7 steps to saveenergy.

(UWA37JAY1–109JAY1, UWA43JATJ–122JATJ, UWA120JY1–270JY1)

Two independent refrigerant circuit.

The selector switch makes it possible to operate only one refrigerant circuitwhile one need repairing.

(UWA63JAY1–109JAY1, UWA70JATJ–122JATJ, UWA120JY1–270JY1)

EER *4(Heating)

5.3 5.7 7.7 9.4 — 11.8 15.8 18.5

YAL9.45 11.44 10.22 — 9.81 11.239.47 11.49 10.25 — 9.87 11.24

TAL 9.74 9.999.74 10.01

YAL

Power comsumption *1(Cooling) 6.8 6.8 8.9 — 11.8 13.6

6.8 6.8 8.9 — 11.8 13.6

Y1TAL 18.6 20.6

18.6 20.6

YAL

Power comsumption(Heating) 6.2 5.7 8.3 — 11.3 12.4

6.2 5.7 8.3 — 11.3 12.4

Y1TAL

kW

kW 17.4 19.417.4 19.4

Net capacity (Btu/h)Unit power comsumption (W)(Compressor + Outdoor fan motor)

EER =

Net capacity (Btu/h)Unit power comsumption (W)(Compressor + Outdoor fan motor)

EER =

°CDB 21 to 52 (UAT06KAY1/TAL/YAL–UAT21KAY1/TAL/YAL, UAT30HY1)

-10 to 15.55 to 52

Operation range (Outdoor temp.)

Operation range(Outdoor temp.)

CoolingHeating

°CDB°CWB