danfoss

2
520F0692 DKBD.PD.040.C2.02 General Data Sheet For specific information on this product, please contact Danfoss Burner Components Electronic Ignition Units EBI C Series The EBI C unit series is specially designed for applications where constant ignition is required. EBI CM is a 2-pole version with secondary mid-point grounded. EBI C1P is a 1-pole ver- sion for ignition between 1 electrode and frame. Both types are characterized by a very good ignition performance. The patent pending ignition unit is available in both the housing types known from the EBI series. EBI CM • Oil/gas burners requiring constant ignition • 2-pole ignition • Secondary mid-point connected to earth/ frame • 100% ED at 35°C/70% ED at 60°C • Top or front connection for secondary cables • 230 V version EBI C1P • Gas burners a.o. application requiring con- stant ignition • 1-pole ignition between 1 electrode and frame • 100% ED at 35°C/70% ED at 60°C • Top or front connection for secondary cables • 230 V version

Upload: bhupendra-mendole

Post on 20-Jan-2015

73 views

Category:

Documents


1 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Danfoss

520F0692 DKBD.PD.040.C2.02

General Data SheetFor specific information on this product, please contact Danfoss Burner Components

Electronic Ignition UnitsEBI C Series

The EBI C unit series is specially designed for applications where constant ignition is required.

EBI CM is a 2-pole version with secondary mid-point grounded. EBI C1P is a 1-pole ver-sion for ignition between 1 electrode and frame.

Both types are characterized by a very good ignition performance.

The patent pending ignition unit is available in both the housing types known from the EBI series.

EBI CM• Oil/gasburnersrequiringconstantignition• 2-poleignition• Secondarymid-pointconnectedtoearth/

frame• 100%EDat35°C/70%EDat60°C• Toporfrontconnectionforsecondary

cables• 230Vversion

EBI C1P• Gasburnersa.o.applicationrequiringcon-

stant ignition• 1-poleignitionbetween1electrodeand

frame• 100%EDat35°C/70%EDat60°C• Toporfrontconnectionforsecondary

cables• 230Vversion

Page 2: Danfoss

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in speci�cations already agreed.All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

520F0692 DKBD.PD.040.C2.02 DanfossA/S©-G1AdvertisingFO/bpv07.09ro

Dimensions

Type EBI CM EBI C1PPrimary connection:Voltage 230V

Current 0.25A

Frequency 50/60HzConsumption 60VAWorking range 187-255VMain fuse 10 AED%in3min. 100%at35°C/70%at60°CSecondary connection:Voltage(peak) 2 ×7,5kV 12kVShortcircuitcurrent(rms) 30mAFrequency 20kHzGeneral data:Ambient temperature -10to+60°CStoragetemperature -25to+85°CEnclosure Primary connection IP 40EMC:Emission EN55014-1Immunity EN55014-2

Primary connection 2×0.75mm2cablewithspecialplug.Cablesin7standardlengthsfrom180mmto630mm2×0.75mm2 cable with standard AMP connection*

Earthing Viatheearthterminal/primaryconnectorDistance between electrodes Recommended2.5mmto5mmWeight 300g

Technical Data

With secondary front connection

Primary plug Bush, secondary

With secondary top connection

Primary plug Bush, secondary