DATA SHEET ATEX CERTIFIED Electric Remote-Control Industrial Fire Suppression SystemThe Elkhart Brass ATEX certified Electric Remote-Controlled fire suppression system is designed to provide reliable industrial fire protection solution for the following classified locations
■ ATEX Zone 1, Zone 2, Zone 21, Zone 22■ IECEx Zone 1, Zone 2, Zone 21, Zone 22■ Ex db eb h II T4 Gb
■ Ex h tb IIIC T130°C Db■ Ex db ec h IIC T4 Gc■ Ex h tc IIIC T130°C De
Features■ 7570 LPM (2000 GPM) maximum flow rate■ Up to 91m (300 ft) stream reach■ 85 Brass monitor construction for corrosive environment
and sea water applications■ Ex d flameproof and Ex e increased safety enclosure■ AC synchronous motors operated monitor for heavy duty
cycle and no risk of overheating■ Double-race brass bearings on vertical and horizontal
swivels ensures monitor reliability and durability ■ Manual override enables manual control at any time
as desired■ Automatic horizontal oscillation. ■ Communication with facility fire detection and alarm
system enables system activation via fire alarm input. Available with network control panel only.
■ Group response enables grouping and activation of group(s) of monitors with input from fire detection system or a panic push button. Available with network control panel only.
■ Optional touch screen HMI control for operation from 2km (1.2 miles distance with multi-mode or 100 km (62 miles) distance with with single-mode fiber optic connection. Available with network control panel only
■ Optional portable Radio Frequency (RF) control with up to 305 m (1000 ft) range. Available with network control panel only
■ Networkable (available with network control panel only.)■ Up to 24 nodes per RF Transmitter■ Up to 24 nodes per system with HMI via Ethernet IP
■ Ethernet IP network communication protocol enables network communication over facility Ethernet network. Available with network control panel only.
■ Cat 5e copper or Fiber (multimode or single mode) networking. Available with network control panel only.
■ Up to 2 km (1.2 mile) distance between nodes with with multi-mode or 100km (62 miles) with single mode fiber optic connection. Available with network control panel only.
■ Integration with field devices such as flame and heat detection systems. Available with network control panel only.
■ Complies with NFPA 70 and EN/IEC 60079-14 ■ 5 Year limited warranty for monitor system and 2-year
limited warranty for control panels
Remote Control ConsoleControl PanelSpitfire Monitor Portable Radio Frequency (RF) Control
1-574-295-8330 www.elkhartbrass.com
SpecificationsMonitor Pressure 14 bar (200 psi)
Flow rate Up to 7570 LPM (2000 GPM) @ 7 bar (100psi)
Inlet Size 4-inch 150# FF flange base inlet
Oscillation range V: +90° to -45° (135°) H: +173° to -173° and 346°
Nozzle Pattern Straight stream to wide fog
Stream Reach Up to 91 m (300 feet)
Material 85 Brass
Monitor Dimensions 889mm x 508mm (Height x Diameter) (35" x 20" )
Junction Box Material 304 Stainless Steel
Junction Box Dimensions 254mm x 254mm x 152mm (H x W x D) (10" x 10" x 6")
Weight 136 kg (300 lbs.)
Ambient Temperature -28°C to 85°C (-18° F to 185° F) with water flowing -40°C to 85°C (-40° F to 185° F) without water flowing
Certification ATEX Zone 1, Zone 2, Zone 21, Zone 22 IECEx Zone 1, Zone 2, Zone 21, Zone 22
Control PanelsStandard Control Panel Network Control Panel
Input Power 2.5A Max. @240VAC 50/60 Hz 2.5A Max. @240VAC 50/60 Hz
Enclosure Dimensions 446 mm x 1275 mm x 295mm (17.5" x 50.2" x 11.7")
446 mm x 1275 mm x 420 mm (17.5" x 50.2" x 16.5)
Enclosure Ingress Protection IP66 IP66
Enclosure Material Cast aluminum ( Ex d Flameproof Enclosure) 316 SS ( Ex e Increased Safety Enclosure)
Cast aluminum ( Ex d Flameproof Enclosure) 316 SS ( Ex e Increased Safety Enclosure)
Weight 80 kg (176 lbs) 146 kg (322 lbs)
Ambient Temperature -20°C to 40°C (-4°F to 104°F) -20°C to 40°C (-4°F to 104°F)
Certification ■ ATEX Zone 1, Zone 2, Zone 21, Zone 22 ■ IECEx Zone 1, Zone 2, Zone 21, Zone 22 ■ ATEX Ex II 2GD Ex db IIB+H2T5 Gb ■ ATEX Ex tb IIIc T135 Db ■ IECEx Ex II 2GD Ex db IIB+H2T5 Gb ■ IECEx Ex tb IIIc T135 Db
■ ATEX Zone 1, Zone 2, Zone 21, Zone 22 ■ IECEx Zone 1, Zone 2, Zone 21, Zone 22 ■ ATEX Ex II 2GD Ex db IIB+H2T5 Gb ■ ATEX Ex tb IIIc T135 Db ■ IECEx Ex II 2GD Ex db IIB+H2T5 Gb ■ IECEx Ex tb IIIc T135 Db
Remote Control ConsoleInput Power 100-120VAC @ <2.1A, 220-240VAC @ 1.0A
Dimensions Screen: L: 15" x W: 15" (381 mm x 381 mm) Mounting: 508 mm x 508 mm x 311.66mm
(L x W x H) (20" x 20" x 12.27")
Enclosure Rating NEMA 12/13/4X, IP54, IP65, for indoor use
Material Painted Carbon Steel
Weight 25 kg (55 lbs.)
Ambient Temperature 0° C to 55° C (32° F to 131° F)
Conductor for Main Control Panel to Monitor ConnectionConductor Maximum distance
#14 AWG Wire 366 to 548.6 m (1201 to 1800 ft)
#12 AWG Wire 548.9 to 914.4 m (1801 to 3000 ft)
#10 AWG 488 m (1600 ft)
Radio Frequency ControlRange Up to 305 m (1000') line of sight range
Battery Type Ni MH
Battery Operation Duration 8-10 hours Continuous
Dimensions 470 mm x 368 mm x 216mm (L x W x H) (18.5" x 14.5" x 8.5")
Material (Bellypack) Cast aluminum
Weight 6 lb. (2.7 kg)
Ambient Temperature -25° C to 55° C (-13° F to 131° F)
Network ConnectivityType Maximum Distance
Between NodesMultimode Fiber Optic Cable 2 km ((1.2 miles))
Single Mode Fiber Optic Cable 100 km (62 miles)
Cat 5e Ethernet Cable 100 m (328 ft)
1-574-295-8330 www.elkhartbrass.com
Ordering InformationIllustration Model
NumberStandard features Options
Monitor
8394-159 08394159 Spit-Fire monitor Electric Remote Controlled Monitor; 220-240VAC (50/60Hz) Synchronous motors; 2,000 GPM (7,570 LPM) max flow rate; 200psi (13.8bar) operating pressure; -45° to +90° (135°) max vertical travel; 347° max horizontal travel; 4.0" 150# ANSI flange inlet; 3.5" NHT male outlet; 85 brass with red urethane enamel; suitable for ATEX Zone 1, Zone 2, Zone 21, Zone 22 and IECEx Zone 1, Zone 2, Zone 21, Zone 22; ATEX and IECEx certified, red paint finish
Cold weather optioning operating with ambient temperature:
-40° F to 185° F (-28° C to 85° C) with water flowing
-18° F to 185° F (-40° C to 85° C) without water flowing
Note: Cold weather monitor is neither ATEX nor IECEx certified
Nozzle
SM1250BE-HL SM-1250BE-HL ATEX ELEC Nozzle; 220-240VAC (50/60Hz) pattern control synchronous motor; 75 psi (5.17 bar); 3.5'' NH female base constant flow; 230ft (70m) effective reach; straight stream; narrow fog (30°) and wide fog (90°); 350 to 1250 GPM (1,330 to 4,750 LPM) flow rate; brass; suitable for ATEX Zone 1, Zone 2, Zone 21, Zone 22 and IECEx Zone 1, Zone 2, Zone 21, Zone 22 classified locations; ATEX and IECEx certified, NFPA 70 (NEC) compliant
Nozzle
SM200BE-HL SM-2000BE-HL ATEX ELEC Nozzle; 220-240VAC (50/60Hz) pattern control synchronous motor; 75 psi (5.17 bar); 3.5'' NH female base constant flow; 320ft (98m) effective reach; straight stream; narrow fog (30°) and wide fog (90°); 500 to 2000 GPM (1,900 to 7,600 LPM) flow rate; brass; suitable for ATEX Zone 1, Zone 2, Zone 21, Zone 22 and IECEx Zone 1, Zone 2, Zone 21, Zone 22 classified locations; ATEX and IECEx certified, NFPA 70 (NEC) compliant
Standard Control Panel
Standard Panel Local Control Panel; machine motor and operator control panel with a complete panel of function controls; suitable for ATEX Zone 1, Zone 2, Zone 21, Zone 22 and IECEx Zone 1, Zone 2, Zone 21, Zone 22; classified location; 240VAC 50/60Hz input voltage; Ex d cast aluminum enclosure; gland plate included
Network Control Panel
Network Panel Local Control Panel; machine motor and operator control panel with a complete panel of function controls; suitable for ATEX Zone 1, Zone 2, Zone 21, Zone 22 and IECEx Zone 1, Zone 2, Zone 21, Zone 22; classified location; 240VAC 50/60Hz input voltage; networkable; Alarm Input/Group Response over Ethernet network; Ex d cast aluminum enclosure; gland plate included
1. Optional multi-mode fiber optic network module
2. RF Control
3. Remote HMI control
1-574-295-8330 www.elkhartbrass.com
Ordering Information Illustration Model
NumberStandard features Options
Optional RF Control
RF Control RF Controls; provide wireless control of up to 10 monitors on a single belly pack. Handheld options available. ATEX Zone 1 certified.
Remote Control Console
HMI Control Remote HMI Touchscreen Controller; Provides Control for up to 20 Monitors. Intuitive touchscreen controller, providing all Operator Control Panel functions and advanced programming and troubleshooting functions; 120/240VAC (50/60Hz); UL listed; painted carbon steel
1. Optional Wall Mount, Free-Standing Console, or Desktop Consolette Enclosures.
2. Optional Fiber Communication Connections.
3. Optional EWON Device (for Elkhart Brass Remote System Troubleshooting)
4. Optional Ergonomic Elabou Joystick
DrawingsMonitor
LOCATE THE JUNCTION BOXAS SHOWN TO AVOID MONITORROTATION INTERFERENCE.
CENTER FRONT
20.20 [513.10 mm]
90°
45°
24.5
0
[622
.40
mm
]
11.00
[279.43 mm]
173.5°173.
5°
20.61 [523.49 mm] SWING RADIUS
10.50
[266.62 mm]
11.22
[284.88 mm]
8.00
[203.26 mm]
NOZZLE P/NPER ORDER
P/N - 08394159ATEX SPITFIRE INDUSTRIALELECTRIC MONITOR
P/N - 81493501MONITOR JUNCTION BOX(SUPPLIED WITH MONITOR)
10.50
[266.62 mm]
FOR ALL PRACTICAL PURPOSE THE NOZZLELENGTHS ARE ALL EQUAL. NOZZLE VARIATIONIS LARGELY IN THE BUMPER DIAMETER.SM-1250 - REF. DIA. 6.87 [174.50 mm]SM-2000 - REF. DIA. 7.93 [201.42 mm]
4"-150# F.F. ANSI FLANGE
NOTE: THIS IS A DIMENSIONAL REFRENCE DRAWING ONLY. DIMENSIONS REPRESENT THE MAXIMUM MONITOR MOVEMENT AND CLEARENCES WITH NOZZLE ATTACHED. DO NOT SCALE DRAWING!
CAT. #284B STREAM SHAPER(SUPPLIED WITH MONITOR
1-574-295-8330 www.elkhartbrass.com
DrawingsStandard Control Panel
338.8 MM (13.340”)
448.5 MM (17.657”)
1275.2 MM (50.205”)
467.5 MM (18.406”) 338.9 MM (13.343”)
308.2 MM (12.134”)
1-574-295-8330 www.elkhartbrass.com
DrawingsNetwork Control Panel
455.0 MM (17.913”)
669.0 MM (26.339”) 455.0 MM (17.913”)
450.7 MM (17.744”)679.5 MM (26.752”)
1457.0 MM (57.362”)
1-574-295-8330 www.elkhartbrass.com
DrawingsHMI Console
A
A
B B
CON 3CON 1
PV 1
BMP 1
ENCL 1
20.28
21.35
SECTION B-B
FP
5251
5152
5251
5152
5251
5152
5251
5152
CON 2
17.84 REF.[453<> mm]
13.31 REF. [338<> mm]
20.28 REF. [515<> mm]
3.28 REF. [83<> mm]
17.00 REF.
LBL 3
1/4" DIA. TYP. 4 PLCS.HOLE FOR RUBBER PUSH-IN BUMPER.
0.50
0.50
5.00
5.50
3.50
15.40[391<> mm]
12.00[305<> mm]
3.50[89<> mm]
2.44[62<> mm]
HINGE SIDE
CUT OUT FOR PANELVIEW
2.44[62<> mm]
4.78[121<> mm]
3.00
1.25
1.20
1.25
1.18
1.200.180
0.090
Elkhart P/N
Elkhart Brass Mfg. Co., Inc.Elkhart, Indiana, USA
FOR USE IN NON-HAZARDOUS LOCATION
STANDARD HMI CONTROL PANEL24352096
SECTION A-A (ROTATED CW30 DEG)
3.28 REF. [83<> mm]
2.00[51<> mm]
2.00[51<> mm]
2.00[51<> mm]
Ø22.5 MM
1.656[42 mm]
Ø.157 [4 mm]
1.339[34 mm]
1.004[25.5 mm]2.00
0.75
UP
DOWN
LEFT
RIGHT
FOG STR
SS 1
LP 1
LP 2
SS 2
JS 1
L1L1
L2/N
L2/N
GG
GG
GG
CB1