data sheets - mita-teknik.com · wp4200 platform control sstems mtwp4200-0 platformdataheet0 20...

86
Data Sheets Turbine Control © 2017 Mita-Teknik. All rights reserved ® Mita-Teknik Advanced Wind Turbine Concept

Upload: duongque

Post on 27-Mar-2019

253 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

Data Sheets Turbine Control

© 2017 Mita-Teknik. All rights reserved®

Mita-TeknikAdvanced Wind Turbine Concept

Page 2: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4200 Platform

MT_WP4200-01 Platform_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4200 ControllerThe WP4200 Platform controllers are based on the multi-core CPU technology. It offers superior performance and with its built-in floating point unit it is perfectly suited for high demanding control- and regulation applications. Furthermore, the controllers are equipped with high-speed gigabit Ethernet interface, for communication in the wind farm. Additionally there is one more Ethernet interface backbone communication to the distributed I/O modules. It also features safety chain relay logic that integrates with the safety system to fulfill the requirements in the ISO 13849-1 standard. In standalone mode WP4200 controller can provide power supply for up to 3 WP-Line modules connected to WP-Line bus.

The controllers of the WP4200 platform are equipped with internal maintenance-free power back-up, ensuring all data is stored in the event of system power failure (UPS shutdown/failure) and program update.

The USB 3.0 port can be used with USB devices complying with the USB Mass Storage Class Specification, like USB Flash drives and hard disc drives, allowing storage of up to 2 TB of data.

The controller uses the advanced OS42xx Operating System software, featuring the Failsafe Flash file system, TCP/IP protocol stack, WEB-server, plug-and-play identification/

configuration of all WP-Line modules, status code system, 30-year summation structure, menu system and log systems.

The OS42xx Operating System API is 100% backwards compatible with the OS4000 and OS4100 operating systems in case of invariant system layout – this ensures that existing applications can be used with the WP4200 Platform controllers without any modification or recompilation.

The module handles the executing of up to 10 different synchronous/asynchronous applications running in parallel. As an example this can be: turbine control application, grid quality monitor and condition monitoring applications, standard communication protocols, customer specific communication protocols, CODESYS RTS, etc.

The controller supports the IEC 61131-3 (CODESYS) PLC programming languages as well as advanced programming in C and C++, using PEPTOOL or other programming tool of your choice.

› CPU module for WP42xx Systems and Concepts

› High performing controller for all types of turbines

› Safe operation in harsh environmental conditions

› Maintenance free - no fans and no replaceable batteries

› Advanced event based data logging and storage

› Direct integration with safety system

› Integrated Failsafe Flash disc

› High-speed multi-core processor (CPU and DSP)

› Built-in floating point unit (FPU) for fast advanced mathematical calculations

› Gigabit Ethernet, Serial RS232/422/485 and USB 3.0 port

› CANopen interface for 3-rd party I/O modules interoperability

Page 3: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4200 Platform

MT_WP4200-01 Platform_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

WP4200 Variants

WP4200 - 00 WP4200 - 08

WP4200 - 09 WP4200 - 10

Page 4: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4200 Platform

MT_WP4200-01 Platform_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

CPU SystemCPUDSPNVRAMDDR lll RAMFlash disk

USBUSB typeUSB ver.Supported devices

Ethernet RJ45 LAN Port Communication speedConnector

Ethernet WP-Line BUS Communication speedConnector

Relay Output - SafetyIsolation typeNominal voltageInput current/signal “1”Input impedance

Redundant System Interface - MasterIsolation typeNominal voltageInput impedance

CANopen Communication PortCommunication speed, max.Max. Cable length, examplesInput impedance

Serial Communication Port - COM 1Port typeCommunication speedConnector

Serial Communication Port - COM 2Port typeCommunication speedConnector

Variant -00 -08 -09 -10Number of inputs None 8 16 8Galvanic isolation - 500 V 500 V 500 VSupported sensorsADC

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input impedanceFrequency range

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input impedanceMinimum pulsewidthSampling rate

Number of outputsOutput type NPNGalvanic isolationNominal voltageMaximum current

Number of inputsGalvanic isolationTemperature measuring rangeAccuracyResolutionCurrent for PT100 inputConversion time for each channel, max

Number of inputsGalvanic isolationInput currentAnalog bandwithAccuracyMeasurement resolutionInput resistance

WP-Line BUS Nominal voltageStandard module load

External 24 V

Variant -00 -08 -09 -10

Maximum 0.9 A @ 24 VDC 1.0 A @ 24 VDC 1.10 A @ 24 VDC 1.10 A @ 24 VDC

Typical 0.5 A @ 24 VDC 0.58 A @ 24 VDC 0.66 A @ 24 VDC 0.65 A @ 24 VDC

Required voltage

Module Power Consumption

Variant -00 -08 -09 -10Typical 12.0 W 13.9 W 15.9 W 15.6 W

Permissible Ambient ConditionsOperation temperatureStorage temperatureRelative humidityOperation altitude

Mechanical Information

Variant -00 -08 -09 -10Weight 0.6 kg 0.66 kg 0.72 kg 0.7 kgDimensions (WxHxD) Required gap (top/buttom)Degree of protection

Applied StandardsDamp heatVibrationBumpShockTemperatureEMC

2 with common ground500 V

15 to 30 VDC0 to 5 VDCMin. 2400 Ω>20ms50 Hz

Digital Output (WP4200 Controller - 10)1

500 V

0.01 mA<200 Ω

2 with common ground500 V -40 to +211°C±0.5% of full scale0.1°CMax. 1 mA250 ms

Analog Inputs (WP4200 Controller - 10)4 with common ground500 V

0 to 100 Hz±0.5% of full scale

0.1 A24 V

Digital Inputs (WP4200 Controller - 10)

Accelerometer Inputs (WP4200 Controller - 08, -09 and -10 only)

Resolution: 24 BitRange of measurement: 0.1 to 25 g (supporting ICP sensors)Frequency range: 0.1 to 10 000 HzSampling rate: 48 kHz

IEPE type - integrated electronics piezoelectric

2500 V

15 to 30 VDC0 to 5 VDC2400 Ω0.05 Hz to 1k Hz

2x ARM Cortex™- A15 1.2 GHz

Dynamic allocated up to 10 MB

3

Current consumption (excluding connected WP-Line modules consumption up to 0.6A):

24 VDC (19 to 30 VDC)

Optocoupler24 VDC1.6 kΩ

USB Mass Storage Class (up to 2TB)3.0Host, type A connector

WP-Line BUS connector (left side) 10/100 Mbit/s

1 GB1 GB SLC NAND + 4 (up to 64) GB eMMC

12 VDC (10.5 to 13.5 VDC)

PT100 Inputs (WP4200 Controller - 10)

High Speed Counter Inputs (WP4200 Controller - 10)

2x TI C66X 750 MHz

Relay contact24 VDC10 mA to 1 A2.4 kΩ

10/100/1000 Mbit/sRJ45 Shielded

0 to 20 mA

RS232 (RTS/CTS), RS422/485300 BAUD to 12 MBAUD (software configuration)9-pin Sub D connector

RS232 (RTS/CTS/RI)300 BAUD to 230.4 kBAUD (software configuration)9-pin Sub D connector

10 kbit/s - 1 mbit/s30 m @ 1 mbit/s 100 m @ 500 kbit/s 500 m @ 125 kbit/s9-pin D-sub male (CiA 303)

EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

170 x 165 x 65 mmMin. 25 mmIP30

EN 60068-2-78EN 60068-2-6EN 60068-2-27EN 60068-2-27EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

-30 to +60°C (fanless operation) -40 to +85°CMax. 95% RH (non-condensing @ 40°C)Max. 2000 m above sea level (up to 4000 m at derated temperature)

Page 5: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4200 Platform

MT_WP4200-01 Platform_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

CPU SystemCPUDSPNVRAMDDR lll RAMFlash disk

USBUSB typeUSB ver.Supported devices

Ethernet RJ45 LAN Port Communication speedConnector

Ethernet WP-Line BUS Communication speedConnector

Relay Output - SafetyIsolation typeNominal voltageInput current/signal “1”Input impedance

Redundant System Interface - MasterIsolation typeNominal voltageInput impedance

CANopen Communication PortCommunication speed, max.Max. Cable length, examplesInput impedance

Serial Communication Port - COM 1Port typeCommunication speedConnector

Serial Communication Port - COM 2Port typeCommunication speedConnector

Variant -00 -08 -09 -10Number of inputs None 8 16 8Galvanic isolation - 500 V 500 V 500 VSupported sensorsADC

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input impedanceFrequency range

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input impedanceMinimum pulsewidthSampling rate

Number of outputsOutput type NPNGalvanic isolationNominal voltageMaximum current

Number of inputsGalvanic isolationTemperature measuring rangeAccuracyResolutionCurrent for PT100 inputConversion time for each channel, max

Number of inputsGalvanic isolationInput currentAnalog bandwithAccuracyMeasurement resolutionInput resistance

WP-Line BUS Nominal voltageStandard module load

External 24 V

Variant -00 -08 -09 -10

Maximum 0.9 A @ 24 VDC 1.0 A @ 24 VDC 1.10 A @ 24 VDC 1.10 A @ 24 VDC

Typical 0.5 A @ 24 VDC 0.58 A @ 24 VDC 0.66 A @ 24 VDC 0.65 A @ 24 VDC

Required voltage

Module Power Consumption

Variant -00 -08 -09 -10Typical 12.0 W 13.9 W 15.9 W 15.6 W

Permissible Ambient ConditionsOperation temperatureStorage temperatureRelative humidityOperation altitude

Mechanical Information

Variant -00 -08 -09 -10Weight 0.6 kg 0.66 kg 0.72 kg 0.7 kgDimensions (WxHxD) Required gap (top/buttom)Degree of protection

Applied StandardsDamp heatVibrationBumpShockTemperatureEMC

2 with common ground500 V

15 to 30 VDC0 to 5 VDCMin. 2400 Ω>20ms50 Hz

Digital Output (WP4200 Controller - 10)1

500 V

0.01 mA<200 Ω

2 with common ground500 V -40 to +211°C±0.5% of full scale0.1°CMax. 1 mA250 ms

Analog Inputs (WP4200 Controller - 10)4 with common ground500 V

0 to 100 Hz±0.5% of full scale

0.1 A24 V

Digital Inputs (WP4200 Controller - 10)

Accelerometer Inputs (WP4200 Controller - 08, -09 and -10 only)

Resolution: 24 BitRange of measurement: 0.1 to 25 g (supporting ICP sensors)Frequency range: 0.1 to 10 000 HzSampling rate: 48 kHz

IEPE type - integrated electronics piezoelectric

2500 V

15 to 30 VDC0 to 5 VDC2400 Ω0.05 Hz to 1k Hz

2x ARM Cortex™- A15 1.2 GHz

Dynamic allocated up to 10 MB

3

Current consumption (excluding connected WP-Line modules consumption up to 0.6A):

24 VDC (19 to 30 VDC)

Optocoupler24 VDC1.6 kΩ

USB Mass Storage Class (up to 2TB)3.0Host, type A connector

WP-Line BUS connector (left side) 10/100 Mbit/s

1 GB1 GB SLC NAND + 4 (up to 64) GB eMMC

12 VDC (10.5 to 13.5 VDC)

PT100 Inputs (WP4200 Controller - 10)

High Speed Counter Inputs (WP4200 Controller - 10)

2x TI C66X 750 MHz

Relay contact24 VDC10 mA to 1 A2.4 kΩ

10/100/1000 Mbit/sRJ45 Shielded

0 to 20 mA

RS232 (RTS/CTS), RS422/485300 BAUD to 12 MBAUD (software configuration)9-pin Sub D connector

RS232 (RTS/CTS/RI)300 BAUD to 230.4 kBAUD (software configuration)9-pin Sub D connector

10 kbit/s - 1 mbit/s30 m @ 1 mbit/s 100 m @ 500 kbit/s 500 m @ 125 kbit/s9-pin D-sub male (CiA 303)

EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

170 x 165 x 65 mmMin. 25 mmIP30

EN 60068-2-78EN 60068-2-6EN 60068-2-27EN 60068-2-27EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

-30 to +60°C (fanless operation) -40 to +85°CMax. 95% RH (non-condensing @ 40°C)Max. 2000 m above sea level (up to 4000 m at derated temperature)

Page 6: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4200 Platform

MT_WP4200-01 Platform_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

CPU SystemCPUDSPNVRAMDDR lll RAMFlash disk

USBUSB typeUSB ver.Supported devices

Ethernet RJ45 LAN Port Communication speedConnector

Ethernet WP-Line BUS Communication speedConnector

Relay Output - SafetyIsolation typeNominal voltageInput current/signal “1”Input impedance

Redundant System Interface - MasterIsolation typeNominal voltageInput impedance

CANopen Communication PortCommunication speed, max.Max. Cable length, examplesInput impedance

Serial Communication Port - COM 1Port typeCommunication speedConnector

Serial Communication Port - COM 2Port typeCommunication speedConnector

Variant -00 -08 -09 -10Number of inputs None 8 16 8Galvanic isolation - 500 V 500 V 500 VSupported sensorsADC

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input impedanceFrequency range

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input impedanceMinimum pulsewidthSampling rate

Number of outputsOutput type NPNGalvanic isolationNominal voltageMaximum current

Number of inputsGalvanic isolationTemperature measuring rangeAccuracyResolutionCurrent for PT100 inputConversion time for each channel, max

Number of inputsGalvanic isolationInput currentAnalog bandwithAccuracyMeasurement resolutionInput resistance

WP-Line BUS Nominal voltageStandard module load

External 24 V

Variant -00 -08 -09 -10

Maximum 0.9 A @ 24 VDC 1.0 A @ 24 VDC 1.10 A @ 24 VDC 1.10 A @ 24 VDC

Typical 0.5 A @ 24 VDC 0.58 A @ 24 VDC 0.66 A @ 24 VDC 0.65 A @ 24 VDC

Required voltage

Module Power Consumption

Variant -00 -08 -09 -10Typical 12.0 W 13.9 W 15.9 W 15.6 W

Permissible Ambient ConditionsOperation temperatureStorage temperatureRelative humidityOperation altitude

Mechanical Information

Variant -00 -08 -09 -10Weight 0.6 kg 0.66 kg 0.72 kg 0.7 kgDimensions (WxHxD) Required gap (top/buttom)Degree of protection

Applied StandardsDamp heatVibrationBumpShockTemperatureEMC

2 with common ground500 V

15 to 30 VDC0 to 5 VDCMin. 2400 Ω>20ms50 Hz

Digital Output (WP4200 Controller - 10)1

500 V

0.01 mA<200 Ω

2 with common ground500 V -40 to +211°C±0.5% of full scale0.1°CMax. 1 mA250 ms

Analog Inputs (WP4200 Controller - 10)4 with common ground500 V

0 to 100 Hz±0.5% of full scale

0.1 A24 V

Digital Inputs (WP4200 Controller - 10)

Accelerometer Inputs (WP4200 Controller - 08, -09 and -10 only)

Resolution: 24 BitRange of measurement: 0.1 to 25 g (supporting ICP sensors)Frequency range: 0.1 to 10 000 HzSampling rate: 48 kHz

IEPE type - integrated electronics piezoelectric

2500 V

15 to 30 VDC0 to 5 VDC2400 Ω0.05 Hz to 1k Hz

2x ARM Cortex™- A15 1.2 GHz

Dynamic allocated up to 10 MB

3

Current consumption (excluding connected WP-Line modules consumption up to 0.6A):

24 VDC (19 to 30 VDC)

Optocoupler24 VDC1.6 kΩ

USB Mass Storage Class (up to 2TB)3.0Host, type A connector

WP-Line BUS connector (left side) 10/100 Mbit/s

1 GB1 GB SLC NAND + 4 (up to 64) GB eMMC

12 VDC (10.5 to 13.5 VDC)

PT100 Inputs (WP4200 Controller - 10)

High Speed Counter Inputs (WP4200 Controller - 10)

2x TI C66X 750 MHz

Relay contact24 VDC10 mA to 1 A2.4 kΩ

10/100/1000 Mbit/sRJ45 Shielded

0 to 20 mA

RS232 (RTS/CTS), RS422/485300 BAUD to 12 MBAUD (software configuration)9-pin Sub D connector

RS232 (RTS/CTS/RI)300 BAUD to 230.4 kBAUD (software configuration)9-pin Sub D connector

10 kbit/s - 1 mbit/s30 m @ 1 mbit/s 100 m @ 500 kbit/s 500 m @ 125 kbit/s9-pin D-sub male (CiA 303)

EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

170 x 165 x 65 mmMin. 25 mmIP30

EN 60068-2-78EN 60068-2-6EN 60068-2-27EN 60068-2-27EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

-30 to +60°C (fanless operation) -40 to +85°CMax. 95% RH (non-condensing @ 40°C)Max. 2000 m above sea level (up to 4000 m at derated temperature)

Page 7: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4200 Platform

MT_WP4200-01 Platform_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Variant Order Name9784201 - 00-01-05 WP4200 Controller with stand-alone capability - Basic

- 08-01-01 WP4200 Controller with stand-alone capability - Basic 8 accelerometer inputs (PCB plug)

- 09-01-01 WP4200 Controller with stand-alone capability -Advanced 16 accelerometer inputs (PCB plugs)

- 10-01-01 WP4200 Controller with stand-alone capability - Extended 8 accelerometer inputs (PCB plug) & I/O

Accessories

For All VariantsWP-Line BUS flat cable 27 mm moldedWP-Line BUS Terminator MK IIWP-Line MK II 80 LED moduleData Cable for CAN/CAN Interface 3.0 m with Female Connector ULData Cable CAN/CAN Interface 2 x 3.0m with Female ConnectorData Cable for CAN/CAN Interface 3.0 m with Male & Female Connector ULSerial Cable RS232 WP4x00 / N-Port 5 mSerial Cable RS232 WP4x00 / N-Port 1.5 mSerial Cable RS232 WP4x00 / Modem 2 mSerial Cable RS232 WP4x00 / PC 3 mEthernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 1 mEthernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 2 mEthernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 5 m

978904200 - 00-00 Connector Kit Screw Black WP4200 - 00

978904200 - 08-01 Connector Kit Screw Black WP4200 - 08-01

978904200 - 09-01 Connector Kit Screw Black WP4200 - 09-01

978904200 - 10-01 Connector Kit Screw Black WP4200 - 10-01Cylindrical Proximity Sensor M12Shielded cable for the Proximity Sensor 10 m

Accelerometer, 100 mV/g, 80 g, 0.5 - 14 000 Hz, M12 top connectorAccelerometer, 500 mV/g, 10 g, 0.2 - 3 700 Hz, M12 top connectorAccelerometer, 100 mV/g, 80 g, 0.5 -12 000 Hz, M12 side connector (incl. M6 bolt)Accelerometer, 500 mV/g, 10 g, 0.2 - 3 700 Hz, M12 side connector (incl. M6 bolt)Accelerometer Cable, Shielded, 4-pin M12 connector, 5 mAccelerometer Cable, Shielded, 4-pin M12 connector, 10 mAccelerometer Cable, Shielded, 4-pin M12 connector, 15 mAccelerometer Cable, Shielded, 4-pin M12 connector, 20 mMounting stud with M6 x 1 to M6 x 1 threadMounting stud with M6 x 1 to M8 x1.25 threadMounting pad, M6 x 1 integral stud, stainless steelMagnetic mounting pad, M6X1 integral stud, stainless steelGlue for accelerometer mounting pads

WP4100 to WP4200 SC/MS Adapter

978800101

9788042

9788080

97881069788106019788108

7983140

8702015

3389250

8946032

8946039

8946029

894604405

7983212

894604410894604415894604420

7983150

7983213

97281069728109

9728108

For upgrade from WP4100 Controller to WP4200 Controller only

978800202

For WP4200 Controller - 00 only

Common for WP4200 Controller - 08, - 09 & -10

For WP4200 Controller - 08 only

For WP4200 Controller - 09 only

For WP4200 Controller - 10 only

76217007628010

978810933892103389220

8946033

Page 8: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4200 Platform

MT_WP4200-01 Platform_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Variant Order Name9784201 - 00-01-05 WP4200 Controller with stand-alone capability - Basic

- 08-01-01 WP4200 Controller with stand-alone capability - Basic 8 accelerometer inputs (PCB plug)

- 09-01-01 WP4200 Controller with stand-alone capability -Advanced 16 accelerometer inputs (PCB plugs)

- 10-01-01 WP4200 Controller with stand-alone capability - Extended 8 accelerometer inputs (PCB plug) & I/O

Accessories

For All VariantsWP-Line BUS flat cable 27 mm moldedWP-Line BUS Terminator MK IIWP-Line MK II 80 LED moduleData Cable for CAN/CAN Interface 3.0 m with Female Connector ULData Cable CAN/CAN Interface 2 x 3.0m with Female ConnectorData Cable for CAN/CAN Interface 3.0 m with Male & Female Connector ULSerial Cable RS232 WP4x00 / N-Port 5 mSerial Cable RS232 WP4x00 / N-Port 1.5 mSerial Cable RS232 WP4x00 / Modem 2 mSerial Cable RS232 WP4x00 / PC 3 mEthernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 1 mEthernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 2 mEthernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 5 m

978904200 - 00-00 Connector Kit Screw Black WP4200 - 00

978904200 - 08-01 Connector Kit Screw Black WP4200 - 08-01

978904200 - 09-01 Connector Kit Screw Black WP4200 - 09-01

978904200 - 10-01 Connector Kit Screw Black WP4200 - 10-01Cylindrical Proximity Sensor M12Shielded cable for the Proximity Sensor 10 m

Accelerometer, 100 mV/g, 80 g, 0.5 - 14 000 Hz, M12 top connectorAccelerometer, 500 mV/g, 10 g, 0.2 - 3 700 Hz, M12 top connectorAccelerometer, 100 mV/g, 80 g, 0.5 -12 000 Hz, M12 side connector (incl. M6 bolt)Accelerometer, 500 mV/g, 10 g, 0.2 - 3 700 Hz, M12 side connector (incl. M6 bolt)Accelerometer Cable, Shielded, 4-pin M12 connector, 5 mAccelerometer Cable, Shielded, 4-pin M12 connector, 10 mAccelerometer Cable, Shielded, 4-pin M12 connector, 15 mAccelerometer Cable, Shielded, 4-pin M12 connector, 20 mMounting stud with M6 x 1 to M6 x 1 threadMounting stud with M6 x 1 to M8 x1.25 threadMounting pad, M6 x 1 integral stud, stainless steelMagnetic mounting pad, M6X1 integral stud, stainless steelGlue for accelerometer mounting pads

WP4100 to WP4200 SC/MS Adapter

978800101

9788042

9788080

97881069788106019788108

7983140

8702015

3389250

8946032

8946039

8946029

894604405

7983212

894604410894604415894604420

7983150

7983213

97281069728109

9728108

For upgrade from WP4100 Controller to WP4200 Controller only

978800202

For WP4200 Controller - 00 only

Common for WP4200 Controller - 08, - 09 & -10

For WP4200 Controller - 08 only

For WP4200 Controller - 09 only

For WP4200 Controller - 10 only

76217007628010

978810933892103389220

8946033

Page 9: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

MT_WP100 Platform_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

control systemsWP100 Platform

Specifications subject to change

The WP100 PlatformThe WP100 Platform is specially designed for control of small and medium sized wind turbines. The basic variant, WP100 Controller – 00, has a set of various on-board I/O channels that makes it possible to use the controller as standalone (w/o additional I/O modules) to control less complex systems. At the same time, it is possible to connect up to 3 WP-Line I/O modules when more I/O channels needed.

The on-board grid interface makes it possible to calculate main grid parameters by precise and reliable DSP algorithms according to IEC 61400-21 standard. The controller is equipped with two high-speed interfaces that work as separate network interfaces. The controller features also safety chain relay logic. The WP100 Controller– 31 with built-in multiport Ethernet switch (among others, includes fiber optic 100BASE-FX port) can be extended with more I/O groups via Backbone interface. The WP100 Controller–32 has built-in GPS receiver and can provide geographic coordinates and accurate time for the system.

All controllers of the WP100 Platform support CANopen Master functionality (optionally). A special application is required to run CANopen and can be delivered on demand.

All controllers of the WP100 Platform are equipped with internal maintenance-free power back-up, ensuring all data is stored in the event of system power failure (UPS

shutdown/failure) and program update. The USB 2.0 port can be used with USB devices complying with the USB Mass Storage Class Specifiation, like USB Flash drives and hard disc drives, allowing storage of up to 2 TB of data. The controller uses the advanced OS1xx Operating System software, featuring the Failsafe Flash file system, TCP/IP protocol stack, WEB-server, plug-and-play identifiation/ confiuration of all WP-Line modules, status code system, 30-year summation structure, menu system and log systems.

The OS1xx Operating System API is 100% backwards compatible with the OS4x00 operating systems family – this ensures that existing applications that run on WP4100 and WP4200 platforms can be installed on the WP100 Platform controllers without any modification or recompilation when the hardware setup is compatible. The controller handles the executing of up to 10 different synchronous/asynchronous applications running in parallel. As an example this can be: turbine control application, park control application, standard communication protocols, customer specifi communication protocols, CoDeSys RTS, etc.

The controller supports the IEC 61131-3 (CoDeSys) PLC programming languages as well as advanced programming in C and C++, using PEPTOOL or other programming tool of your choice.

› CPU module for small and medium sized wind turbines

› Safe operation in harsh environments › Maintenance free - no fans and no batteries that need replacement

› Advanced event based data logging and storage

› Ethernet, Serial RS232/RS422/RS485 and USB 2.0 port

› 16 digital inputs/outputs, 4 high speed digital counters › 4 PT100 inputs, 4 analog inputs and 1 analog output

› 1 CAN/CANopen interface

› Direct integration with safety system

› 1 Grid measurement (3 current and 3 voltage inputs)

› Built-in multiport Ethernet switch

› Built-in GPS receiver

Page 10: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

MT_WP100 Platform_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

control systemsWP100 Platform

Specifications subject to change

WP100 Variants

WP100 - 00 WP100 - 30

WP100 - 31 WP100 - 32

Page 11: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

MT_WP100 Platform_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

control systemsWP100 Platform

Specifications subject to change

Technical Data

CPU SystemCPUDDR lll RAMFlash Disk

USB typeUSB versionSupported devices

Ethernet RJ45 LAN Port Variant – 00 – 30 – 31 – 32Number of ports 2 2 3 2LAN1 Communication speed, Mbit/s 10/100 10/100 10/100 10/100LAN2 Communication speed, Mbit/s 10/100 10/100 10/100 10/100LAN3 Communication speed, Mbit/s N/A N/A 10/100 N/AConnector

Communication speedRange, maximum recommendedFibre typeWave length

Isolation typeNominal voltageInput current/signal “1”Input impedance

Port typeRS232 mode:Communication speedMax. cable lengthRecommend cabe typeRS485/RS422 mode:Communication speedMax. cable lengthRecommend cabe typeTermination

Galvanic isolationCable impedanceCommunication speed

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input currentInput impedanceMinimum pulsewidthSampling rate

Number of inputsGalvanic isolationOutput voltage:Low level (Off)High level (On)Output currentNumber of groupsPoints per groupOverall “group current limit”Minimum load impedanceProtected from short circuit events

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input impedanceFrequency range

Number of inputsGalvanic isolationTemperature measuring rangeAccuracyResolutionCurrent for PT100 inputConversion time for each channel, max

Number of inputsGalvanic isolationInput currentAnalog bandwithAccuracyMeasurement resolutionInput resistance

Number of outputsGalvanic isolationOutput rangeAnalog bandwithMinimum load resistance AccuracyResolution

GPS informationConnector typeRF input impedancePower supply for antennaGalvanic isolation

No. of current inputsCurrent input rangeCurrent input impedanceCurrent accuracy

No. of voltage inputsVoltage input rangeVoltage input impedanceVoltage accuracy

Measurement frequency band width

100 kΩ±0.3% of full scale, within measurement frequency and operating temperature range40 Hz to 9 kHz

31 A RMS40 mΩ

and operating temperature range 318 V RMS

±0.5% of full scale, within measurement frequency

GPS Receiver (WP100 Controller – 32 only)Coordinates, time informationSMA female receptacle50 Ohm - 1575.42 MHz3.3 V up to 30 mAYes

Grid Measurement Input (WP100 Controller – 30, – 31, – 32 only)

Yes0 to 10 V0 to 300 Hz1kΩ (max 10 mA @ 10 V)±0.5% of full scale2.66 mV

0.01 mA<200 Ω

Analog Output1

Analog Inputs4 with common groundYes0 to 20 mA0 to 100 Hz±0.5% of full scale

-40 to +211°C±0.5% of full scale0.1°CMax. 1 mA250 ms

2400 Ω0.01 Hz to 80 kHz

PT100 Inputs4Yes

High Speed Counter Inputs4Yes

15 to 30 VDC0 to 5 VDC

282 A100 ΩYes

16 with common groundNo

0 to 2 VDC0.95 x supply voltageMax. 0.25 A for each

Max. 25 mA Min. 2400 Ω>20 ms50 Hz

Digital Outputs

Digital Inputs16 with common groundNo

15 to 30 VDC0 to 5 VDC

120 Ω10 kbit/s to 1 Mbit/s

Max. cable length, examples 30 m @ 1 Mbit/s100 m @ 500 kbit/s500 m @ 125 kbit/s

Max. 1200 m at 9.6kBAUDMulti wire cable with shieldMount at line ends

CAN Communication PortYes

1.2 to 230.4 kBAUD (software configuration)5 mMulti wire cable with shield

1.2 to 115.2 kBAUD

24 VDC10 mA to 1 A2.4 kΩ

Serial Communication Port - COMRS485/RS422/RS232

1024 MB1024 MB

ARM Cortex™- A8 1000 MHz

RJ45 shielded

LAN4 Ethernet Optical Communication Port (WP100 Controller – 31 Only)

2000 m62.5/125 μm1300 nm

Relay Output - SafetyRelay contact

100 Mbit/s

USBHost, type A connector2.0USB mass storage Class (up to 2TB)

Page 12: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

MT_WP100 Platform_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

control systemsWP100 Platform

Specifications subject to change

Technical Data

CPU SystemCPUDDR lll RAMFlash Disk

USB typeUSB versionSupported devices

Ethernet RJ45 LAN Port Variant – 00 – 30 – 31 – 32Number of ports 2 2 3 2LAN1 Communication speed, Mbit/s 10/100 10/100 10/100 10/100LAN2 Communication speed, Mbit/s 10/100 10/100 10/100 10/100LAN3 Communication speed, Mbit/s N/A N/A 10/100 N/AConnector

Communication speedRange, maximum recommendedFibre typeWave length

Isolation typeNominal voltageInput current/signal “1”Input impedance

Port typeRS232 mode:Communication speedMax. cable lengthRecommend cabe typeRS485/RS422 mode:Communication speedMax. cable lengthRecommend cabe typeTermination

Galvanic isolationCable impedanceCommunication speed

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input currentInput impedanceMinimum pulsewidthSampling rate

Number of inputsGalvanic isolationOutput voltage:Low level (Off)High level (On)Output currentNumber of groupsPoints per groupOverall “group current limit”Minimum load impedanceProtected from short circuit events

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input impedanceFrequency range

Number of inputsGalvanic isolationTemperature measuring rangeAccuracyResolutionCurrent for PT100 inputConversion time for each channel, max

Number of inputsGalvanic isolationInput currentAnalog bandwithAccuracyMeasurement resolutionInput resistance

Number of outputsGalvanic isolationOutput rangeAnalog bandwithMinimum load resistance AccuracyResolution

GPS informationConnector typeRF input impedancePower supply for antennaGalvanic isolation

No. of current inputsCurrent input rangeCurrent input impedanceCurrent accuracy

No. of voltage inputsVoltage input rangeVoltage input impedanceVoltage accuracy

Measurement frequency band width

100 kΩ±0.3% of full scale, within measurement frequency and operating temperature range40 Hz to 9 kHz

31 A RMS40 mΩ

and operating temperature range 318 V RMS

±0.5% of full scale, within measurement frequency

GPS Receiver (WP100 Controller – 32 only)Coordinates, time informationSMA female receptacle50 Ohm - 1575.42 MHz3.3 V up to 30 mAYes

Grid Measurement Input (WP100 Controller – 30, – 31, – 32 only)

Yes0 to 10 V0 to 300 Hz1kΩ (max 10 mA @ 10 V)±0.5% of full scale2.66 mV

0.01 mA<200 Ω

Analog Output1

Analog Inputs4 with common groundYes0 to 20 mA0 to 100 Hz±0.5% of full scale

-40 to +211°C±0.5% of full scale0.1°CMax. 1 mA250 ms

2400 Ω0.01 Hz to 80 kHz

PT100 Inputs4Yes

High Speed Counter Inputs4Yes

15 to 30 VDC0 to 5 VDC

282 A100 ΩYes

16 with common groundNo

0 to 2 VDC0.95 x supply voltageMax. 0.25 A for each

Max. 25 mA Min. 2400 Ω>20 ms50 Hz

Digital Outputs

Digital Inputs16 with common groundNo

15 to 30 VDC0 to 5 VDC

120 Ω10 kbit/s to 1 Mbit/s

Max. cable length, examples 30 m @ 1 Mbit/s100 m @ 500 kbit/s500 m @ 125 kbit/s

Max. 1200 m at 9.6kBAUDMulti wire cable with shieldMount at line ends

CAN Communication PortYes

1.2 to 230.4 kBAUD (software configuration)5 mMulti wire cable with shield

1.2 to 115.2 kBAUD

24 VDC10 mA to 1 A2.4 kΩ

Serial Communication Port - COMRS485/RS422/RS232

1024 MB1024 MB

ARM Cortex™- A8 1000 MHz

RJ45 shielded

LAN4 Ethernet Optical Communication Port (WP100 Controller – 31 Only)

2000 m62.5/125 μm1300 nm

Relay Output - SafetyRelay contact

100 Mbit/s

USBHost, type A connector2.0USB mass storage Class (up to 2TB)

Page 13: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

MT_WP100 Platform_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

control systemsWP100 Platform

Specifications subject to change

Technical Data

CPU SystemCPUDDR lll RAMFlash Disk

USB typeUSB versionSupported devices

Ethernet RJ45 LAN Port Variant – 00 – 30 – 31 – 32Number of ports 2 2 3 2LAN1 Communication speed, Mbit/s 10/100 10/100 10/100 10/100LAN2 Communication speed, Mbit/s 10/100 10/100 10/100 10/100LAN3 Communication speed, Mbit/s N/A N/A 10/100 N/AConnector

Communication speedRange, maximum recommendedFibre typeWave length

Isolation typeNominal voltageInput current/signal “1”Input impedance

Port typeRS232 mode:Communication speedMax. cable lengthRecommend cabe typeRS485/RS422 mode:Communication speedMax. cable lengthRecommend cabe typeTermination

Galvanic isolationCable impedanceCommunication speed

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input currentInput impedanceMinimum pulsewidthSampling rate

Number of inputsGalvanic isolationOutput voltage:Low level (Off)High level (On)Output currentNumber of groupsPoints per groupOverall “group current limit”Minimum load impedanceProtected from short circuit events

Number of inputsGalvanic isolationNominal voltage:Signal "1"Signal "0"Input impedanceFrequency range

Number of inputsGalvanic isolationTemperature measuring rangeAccuracyResolutionCurrent for PT100 inputConversion time for each channel, max

Number of inputsGalvanic isolationInput currentAnalog bandwithAccuracyMeasurement resolutionInput resistance

Number of outputsGalvanic isolationOutput rangeAnalog bandwithMinimum load resistance AccuracyResolution

GPS informationConnector typeRF input impedancePower supply for antennaGalvanic isolation

No. of current inputsCurrent input rangeCurrent input impedanceCurrent accuracy

No. of voltage inputsVoltage input rangeVoltage input impedanceVoltage accuracy

Measurement frequency band width

100 kΩ±0.3% of full scale, within measurement frequency and operating temperature range40 Hz to 9 kHz

31 A RMS40 mΩ

and operating temperature range 318 V RMS

±0.5% of full scale, within measurement frequency

GPS Receiver (WP100 Controller – 32 only)Coordinates, time informationSMA female receptacle50 Ohm - 1575.42 MHz3.3 V up to 30 mAYes

Grid Measurement Input (WP100 Controller – 30, – 31, – 32 only)

Yes0 to 10 V0 to 300 Hz1kΩ (max 10 mA @ 10 V)±0.5% of full scale2.66 mV

0.01 mA<200 Ω

Analog Output1

Analog Inputs4 with common groundYes0 to 20 mA0 to 100 Hz±0.5% of full scale

-40 to +211°C±0.5% of full scale0.1°CMax. 1 mA250 ms

2400 Ω0.01 Hz to 80 kHz

PT100 Inputs4Yes

High Speed Counter Inputs4Yes

15 to 30 VDC0 to 5 VDC

282 A100 ΩYes

16 with common groundNo

0 to 2 VDC0.95 x supply voltageMax. 0.25 A for each

Max. 25 mA Min. 2400 Ω>20 ms50 Hz

Digital Outputs

Digital Inputs16 with common groundNo

15 to 30 VDC0 to 5 VDC

120 Ω10 kbit/s to 1 Mbit/s

Max. cable length, examples 30 m @ 1 Mbit/s100 m @ 500 kbit/s500 m @ 125 kbit/s

Max. 1200 m at 9.6kBAUDMulti wire cable with shieldMount at line ends

CAN Communication PortYes

1.2 to 230.4 kBAUD (software configuration)5 mMulti wire cable with shield

1.2 to 115.2 kBAUD

24 VDC10 mA to 1 A2.4 kΩ

Serial Communication Port - COMRS485/RS422/RS232

1024 MB1024 MB

ARM Cortex™- A8 1000 MHz

RJ45 shielded

LAN4 Ethernet Optical Communication Port (WP100 Controller – 31 Only)

2000 m62.5/125 μm1300 nm

Relay Output - SafetyRelay contact

100 Mbit/s

USBHost, type A connector2.0USB mass storage Class (up to 2TB)

Isolation typeNominal voltageInput current/signal “1”Input impedance

WP-Line BUS Nominal voltageStandard module load

External 24 VVariant – 00 – 30 – 31 – 32Current consumption:Typical (all digital outputs at '0' state) 0,27 A @ 24 VDC 0,35 A @ 24 VDC 0,48 A @ 24 VDC 0,37 A @ 24 VDC

Maximum (all digital outputs at '1' state) 4,37 A @ 24 VDC 4,45 A @ 24 VDC 4,58 A @ 24 VDC 4,47 A @ 24 VDC

Required voltage

Variant – 00 – 30 – 31 – 32Typical (excluding load on digital outputs), W 6.50 8.40 11.50 8.90

Operation temperatureStorage temperatureRelative humidityOperation altitude

Mechanical InformationVariant – 00 – 30 – 31 – 32Weight 0.52 kg 0.56 kg 0.60 kg 0.58 kgDimensions (WxHxD) Required gap (top/buttom)Degree of protection

Damp heatVibrationBumpShockTemperatureEMC

Power quality of wind turbine

Grid codes reference document

techniques)

EN 61400-21, Wind Turbines - Part 21: Measurement and assesment

EN 60068-2-6EN 60068-2-27EN 60068-2-27EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

6

24 VDC (19 to 30 VDC)

Relay contact24 VDC10 mA to 1 A2.4 kΩ

12 VDC (10.5 to 13.5 VDC)

quality characteristics of grid connected wind turbinesBDEW: Generating Plants Connected to the Medium - Voltage Network (June 2008)

Module Power Consumption

EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)EN 61000-4-7:2002 + A1:2009 (Testing and measurement

General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto

Applied StandardsEN 60068-2-78

Permissible Ambient Conditions -30 to +60°C (fanless operation) -40 to +85°CMax. 95% RH (non-condensing @ 40°C)Max. 2000 m above sea level(up to 4000 m at derated temperature)

170 x 165 x 65 mmMin. 25 mmIP30

Relay Output - Grid Measurement (WP100 Controller – 30, – 31, – 32 only)

Page 14: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

MT_WP100 Platform_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

control systemsWP100 Platform

Specifications subject to change

Technical Data

Isolation typeNominal voltageInput current/signal “1”Input impedance

WP-Line BUS Nominal voltageStandard module load

External 24 VVariant – 00 – 30 – 31 – 32Current consumption:Typical (all digital outputs at '0' state) 0,27 A @ 24 VDC 0,35 A @ 24 VDC 0,48 A @ 24 VDC 0,37 A @ 24 VDC

Maximum (all digital outputs at '1' state) 4,37 A @ 24 VDC 4,45 A @ 24 VDC 4,58 A @ 24 VDC 4,47 A @ 24 VDC

Required voltage

Variant – 00 – 30 – 31 – 32Typical (excluding load on digital outputs), W 6.50 8.40 11.50 8.90

Operation temperatureStorage temperatureRelative humidityOperation altitude

Mechanical InformationVariant – 00 – 30 – 31 – 32Weight 0.52 kg 0.56 kg 0.60 kg 0.58 kgDimensions (WxHxD) Required gap (top/buttom)Degree of protection

Damp heatVibrationBumpShockTemperatureEMC

Power quality of wind turbine

Grid codes reference document

techniques)

EN 61400-21, Wind Turbines - Part 21: Measurement and assesment

EN 60068-2-6EN 60068-2-27EN 60068-2-27EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

6

24 VDC (19 to 30 VDC)

Relay contact24 VDC10 mA to 1 A2.4 kΩ

12 VDC (10.5 to 13.5 VDC)

quality characteristics of grid connected wind turbinesBDEW: Generating Plants Connected to the Medium - Voltage Network (June 2008)

Module Power Consumption

EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)EN 61000-4-7:2002 + A1:2009 (Testing and measurement

General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto

Applied StandardsEN 60068-2-78

Permissible Ambient Conditions -30 to +60°C (fanless operation) -40 to +85°CMax. 95% RH (non-condensing @ 40°C)Max. 2000 m above sea level(up to 4000 m at derated temperature)

170 x 165 x 65 mmMin. 25 mmIP30

Relay Output - Grid Measurement (WP100 Controller – 30, – 31, – 32 only)

Page 15: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

MT_WP100 Platform_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

control systemsWP100 Platform

Specifications subject to change

Mita-Teknik Ordering Information

Configuration List

Order Name LAN1 / LAN2 Mbit/s

LAN3 / LAN4 Mbit/s

Grid Measurement Input

GPS Receiver

WP100 Controller - 00 10/100 - - -WP100 Controller - 30 10/100 - x -WP100 Controller - 31 10/100 10/100 x -WP100 Controller - 32 10/100 - x x

Order Number Variant Order Name9780100 -00-01-00 WP100 Controller - 00

-30-01-00 WP100 Controller - 30 (Grid)-31-01-00 WP100 Controller - 31 (Grid & Fiberoptic)-32-01-00 WP100 Controller - 32 (Grid & GPS)

Accessories978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line BUS Terminator MK II978910001 Connector Kit Screw Black WP100 Controller – 00978913001 Connector Kit Screw Black WP100 Controller – 30 / – 32978913101 Connector Kit Screw Black WP100 Controller – 319788100 Serial Cable RS485 WP100-xx - WP4059 2.5 m9788101 Serial Cable RS232 WP100-xx - PC 3 m978802320 Cable WP100-3x / WP3090 2 m3389210 Ethernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 1 m3389220 Ethernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 2 m3389250 Ethernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 5 m3389310 Ethernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 10 m3389315 Ethernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 15 m3389330 Ethernet Patch Cable RJ45, Cat. 6 STP Shielded Grey 30 m3370515 Fibre Optical Patch Cable 2X 62.5µm SC/SC-D 1 m3370525 Fibre Optical Patch Cable 2X 62.5µm SC/SC 2 m3370545 Fibre Optical Patch Cable 2X 62.5µm SC/SC-D 5 m8945280 GPS Active Antenna8661080 GPS Antenna Mount, 90°8661071 GPS Antenna Mount straight746813505 GPS Antenna Cable RG58 TNC - SMA 5 M746813510 GPS Antenna Cable RG58 TNC - SMA 10 M746813525 GPS Antenna Cable RG58 TNC - SMA 25 M

Page 16: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 111 MK ll Power Supply/Backbone

MT_WP-Line 111 MK ll_DataSheet_R6_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 111 MK ll Power Supply/Backbone module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures opti-mal operation, high security, and advanced data collection.

The concept typically consists of a power supply/backbone module, a WP4100 MK ll controller, a grid measurement module as well as an analog/digital I/O module depend-ent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solu-tions. The concept is constructed as a plug-and-play sys-tem with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Service-friendly

The WP-Line 111 MK llThe WP-Line 111 MK ll Power Supply/Backbone module is an improvement of the older WP-Line 110 and functions as power supply for the single module blocks in the WP4x00 MK ll Control Concept. The inter-block communication (backbone) in the WP4x00 MK ll Control Concept is carried out by the WP-Line 111 MK ll via an optical Ethernet. The backbone is constructed as a single ring. The fibre optic type is 62.5/125µm.

Furthermore, the WP-Line 111 MK ll is equipped with 2 x 100Mbit Ethernet RJ45 plugs for connection of a graphi-cal display/keypad or PC. This enables operating the com-plete WP4x00 MK ll Control System at all available module blocks.

› High-efficiency power supply for the WP4x00 MK ll Control Concept - up to 15 WP-Line modules can be connected

› Optical backbone Ethernet with optional redundancy › 2 RJ45 Ethernet plugs for display and service

› Activity LED showing operational status

› Fast and easy DIN-rail mounting

› Supports removable LED matrix display

› New flexible serial COM-port

› Intelligent thermal control

Page 17: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 111 MK ll Power Supply/Backbone

MT_WP-Line 111 MK ll_DataSheet_R6_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Supply Voltage 1Nominal 24 VDCAllowed range 18 to 30 VDCCurrent consumption <0,3 A - 2,0 A

WP-Line BUS SupplyVoltage delivered, nominal 12 VDCAllowed range 11.5 to 12.75 VDCDelivered current, maximum 3A/15 standard module loads*

Ethernet 2 x RJ45Ethernet 2 x SCSerial COM-Port 1

Communication speed 10/100 mbit/sRange, maximum recommended 50 m

Communication speed 100 mbit/sRange, maximum recommended 2000 mFibre type 62.5/125 μmWave length 1300 nm

No. of ports 1Isolation Digital isolator (4000-V peak isolation, 560-Vpeak VIORM)Communication speed 300 BAUD to 230.4 kBAUD (software configuration)

RS422 max. 1200 meters @ 2 nodes RS485 max. 1200 meters @ 1.2K BAUDRS232 max. 30 m

Recommended cable type Multi wire cable with shieldTermination For RS422 and RS485 mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

Permissible Ambient ConditionsOperation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CRelative humidity max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/bottom) Min. 25 mmWeight 370 gDegree of protection IP30

BUS Port Connectors

ETHERNET RJ45 Communication Port

ETHERNET Optical Communication Port

Port for RS232/RS422/RS485 Communication

Max. cable length

Technical Data

Page 18: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 111 MK ll Power Supply/Backbone

MT_WP-Line 111 MK ll_DataSheet_R6_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Mita-Teknik Ordering Information

Technical Data

3370545 Fibre Optical Patch Cable 2X 62.5µm SC/SC-D 5 mConnector Kit Screw Black WP-Line 111 MK ll

978011102 WP-Line 111 MK ll Power Backbone

9788080 WP-Line 80 LED module

9788106 Serial Cable RS232 WP4x00 / N-Port 5 m

Order Number

9788108 Serial Cable RS232 WP4x00 / Modem 2 m

Accessories

Order Name

978800101 WP-Line Bus Flat Cable 27 mm molded

978810601 Serial Cable RS232 WP4x00 / N-Port 1.5 m

9788102 Serial Cable RS485 WP-Line 111/351 - WP4086 10 m9788103 Serial Cable RS485 WP-Line 111/351 - WP4059 2.5 m9788104 Serial Cable RS232 WP-Line 111/351 - DP9 male (UPS) 2 m9788105 Serial Cable RS232 WP-Line 111/351 - PC 2 m

9788109 Serial Cable RS232 WP4x00 / PC 3 m3389210 Ethernet Patch Cable 1 m

3370525

978911101

Fibre Optical Patch Cable 2X 62.5µm SC/SC 2 m

3389220 Ethernet Patch Cable 2 m

33705153389250 Ethernet Patch Cable 5 m

978800202 WP-Line Bus Terminator MK II

Fibre Optical Patch Cable 2X 62.5µm SC/SC-D 1 m

Page 19: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 112 MK II Gigabit Ethernet Switch/PSU

MT_WP-Line 112 MK ll_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 112 MK ll Gigabit Ethernet Switch/PSU module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and advanced data collection.

The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Service-friendly

The WP-Line 112 MK ll Gigabit Ethernet Switch/PSUThe WP-Line 112 MK ll is a high-speed backbone communi-cation module with several connection posibilities. It functions as power supply for the single module blocks in the WP4x00 MK ll Control Concept.

The inter-block communication (backbone) in the WP4x00 MK ll Control Concept is carried out by the WP-Line 112 MK ll via an optical Ethernet. The backbone is constructed as a single ring. The fiber optic type is 62.5/125μm or 50/125μm.Furthermore, the WP-Line 112 MK ll is equipped with four Gigabit Ethernet RJ 45 plugs for connection of a graphical display/keypad or PC. Hence, operating the complete WP4x00 MK ll Control System is possible at all available module blocks.

Features:› Up to 1 MBit/s CANopen Master communication to other CANopen based devices› Galvanic isolated CANbus interface› Internal condition monitoring› 7-segment display showing group number and 3-LED status indication for fast servicing

Automatic firmware update is managed by the WP4x00 MK ll controller. The module can easily be programmed as a CANopen Master, interfacing the WP4x00 MK ll controller to any CANopen device (frequency converter, Pitch controller etc.). Via the generic CANopen application (in compliance with CiA301 and CiA DSP 302 specification standards) and user-friendly interface of the Mita-Teknik “CANopen Configuration Tool”, all CANopen network parameters can easily be configured and adjusted.

› High-efficiency power supply for the WP4x00 MK ll Control Concept - up to 15 WP-Line modules can be connected › Support of Gigabit Ethernet

› Park network connectivity

› Possibility to extend with support of leading Industrial Ethernet protocols (IEE1588v2, PROFIBUS DP master, EtherCAT master)

› 4 RJ45 Ethernet ports 2 (4) optical ports (SFP or SC) 2 external COM-ports Suppport of SSI interface on COM-port 2 external CANopen ports

› Possibility to extend I/O capabilities

› Activity LED showing operational status

› Fast and easy DIN-rail mounting

› Supports removable LED matrix display

› Intelligent thermal control

Page 20: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 112 MK II Gigabit Ethernet Switch/PSU

MT_WP-Line 112 MK ll_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

NominalAllowed rangeCurrent consumption

Voltage delivered, nominal Allowed rangeDelivered current, maximum

Variant -01 -02 -03 -04Ethernet CopperEthernet Fibre Optic 4 x SFP 2 x SFP, 2 x SC 2 x SC 2 x SFP, 2 x SCSerial COM-PortCAN port

Communication speed, max.Max. cable length, examples

Connector

Communication speedRange, maximum recommended

Communication speedDistance

Communication speedFibre typeWave lengthDistance

No. of portsCommunication speedSSI clock frequency

Recommended cable typeTerminationConnector

Number of inputsGalvanic isolation

Signal "1"Signal "0"Input impedanceFrequency range

Number of inputsGalvanic isolation

Signal "1"Signal "0"Input impedanceMinimum pulsewidthSampling rate

Number of outputsOutput typeGalvanic isolationNominal voltageMaximum current

Number of inputsGalvanic isolationTemperature measuring rangeAccuracyResolutionCurrent for PT100 inputConversion time for each channel, max

Number of inputsGalvanic isolationInput currentAnalog bandwithAccuracyMeasurement resolutionInput resistance

Operation temperatureStorage temperatureRelative humidityOperation altitude

Dimensions (WxHxD)Required gap (top/bottom)WeightIngress Protection RatingMounting Method

Damp heatVibrationBumpShockTemperatureEMC

0.01 mA

*For load of individual modules, see specific technical manuals

500 V -40 to +211°C±0.5% of full scale0.1°CMax. 1 mA

2 with common ground

500 V

15 to 30 VDC

<200 Ω

4 with common ground500 V0 to 20 mA0 to 100 Hz

1NPN500 V24 V0.1 A

>20ms50 Hz

4 x RJ45

24 VDC18 to 30 VDC<0,3 A - 2,0 A

12 VDC11.5 to 12.75 VDC

BUS Port Connectors

3A/15 standard module loads*

2500 V

Ethernet Optical Communication Port SFP (not available for WP-Line 112 MK ll Gigabit Ethernet Switch/PSU - 03)

100/1000 Mbit/s

Up to 2 km with 50/62.5 μm multimode optic at 100 Mbit/sUp to 550 m with 50/125 μm multimode optic at 1000 Mbit/sUp to 40 km with 9 μm singlemode optic at 100 Mbit/sUp to 10 km with 9 μm singlemode optic at 1000 Mbit/s

300 BAUD to 230.4 kBAUD (software configuration)

22

(up to 4000 m at derated temperature range)

Nominal voltage:

Nominal voltage:

2400 Ω

2 with common ground

Digital Output (for variants - 01 and - 02 only)

0 to 5 VDCMin. 2400 Ω

Mechanical Information

-40 to +85 °Cmax. 95% RH (non-condensing @ 40 °C)

250 ms

Permissible Ambient Conditions

Max. 2000 m above sea level

-30 to +60°C (fanless operation)

±0.5% of full scale

Up to 2 km

Multimode 62.5/125 μm or 50/125 μm

10 kbit/s - 1 Mbit/s

50 m

CANopen Communication Port

Port for RS232/RS422/RS485 Communication, SSI

I/O Capabilities (WP-Line 112 MK ll Gigabit Ethernet Switch/PSU - 01 and 02 only)

High Speed Counter Inputs (for variants - 01 and - 02 only)

Max. cable length

2

Up to 2 MHz

PT100 Inputs (for variants - 01 and - 02 only)

30 m @ 1 Mbit/s100 m @ 500 kbit/s500 m @ 125 kbit/s9-pin D-sub male (CiA 303)

Digital Inputs (for variants - 01 and - 02 only)

15 to 30 VDC0 to 5 VDC

0.05 Hz to 1k Hz

Analog Inputs (for variants - 01 and - 02 only)

Ethernet RJ45 Communication Port 10/100/1000 Mbit/s

For RS422 and RS485 mount 120 Ω at line ends6-pin 5.08 mm plugin terminal block with EARTH

Ethernet Optical Communication Port SC (not available for WP-Line 112 MK ll Gigabit Ethernet Switch/PSU - 01)

100 Mbit/s

1300 nm

EN 60068-2-27EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

170 x 166 x 65 mmMin. 25 mmApprox. 650 gIP30

Applied Standards

Supply Voltage

WP-Line BUS Supply

DIN-rail mounting

EN60068-2-78EN 60068-2-6EN 60068-2-27

RS422 max. 1200 meters @ 2 nodes RS485 max. 1200 meters @ 1.2K BAUDRS232 max. 30 mMulti wire cable with shield

Technical Data

Page 21: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 112 MK II Gigabit Ethernet Switch/PSU

MT_WP-Line 112 MK ll_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

NominalAllowed rangeCurrent consumption

Voltage delivered, nominal Allowed rangeDelivered current, maximum

Variant -01 -02 -03 -04Ethernet CopperEthernet Fibre Optic 4 x SFP 2 x SFP, 2 x SC 2 x SC 2 x SFP, 2 x SCSerial COM-PortCAN port

Communication speed, max.Max. cable length, examples

Connector

Communication speedRange, maximum recommended

Communication speedDistance

Communication speedFibre typeWave lengthDistance

No. of portsCommunication speedSSI clock frequency

Recommended cable typeTerminationConnector

Number of inputsGalvanic isolation

Signal "1"Signal "0"Input impedanceFrequency range

Number of inputsGalvanic isolation

Signal "1"Signal "0"Input impedanceMinimum pulsewidthSampling rate

Number of outputsOutput typeGalvanic isolationNominal voltageMaximum current

Number of inputsGalvanic isolationTemperature measuring rangeAccuracyResolutionCurrent for PT100 inputConversion time for each channel, max

Number of inputsGalvanic isolationInput currentAnalog bandwithAccuracyMeasurement resolutionInput resistance

Operation temperatureStorage temperatureRelative humidityOperation altitude

Dimensions (WxHxD)Required gap (top/bottom)WeightIngress Protection RatingMounting Method

Damp heatVibrationBumpShockTemperatureEMC

0.01 mA

*For load of individual modules, see specific technical manuals

500 V -40 to +211°C±0.5% of full scale0.1°CMax. 1 mA

2 with common ground

500 V

15 to 30 VDC

<200 Ω

4 with common ground500 V0 to 20 mA0 to 100 Hz

1NPN500 V24 V0.1 A

>20ms50 Hz

4 x RJ45

24 VDC18 to 30 VDC<0,3 A - 2,0 A

12 VDC11.5 to 12.75 VDC

BUS Port Connectors

3A/15 standard module loads*

2500 V

Ethernet Optical Communication Port SFP (not available for WP-Line 112 MK ll Gigabit Ethernet Switch/PSU - 03)

100/1000 Mbit/s

Up to 2 km with 50/62.5 μm multimode optic at 100 Mbit/sUp to 550 m with 50/125 μm multimode optic at 1000 Mbit/sUp to 40 km with 9 μm singlemode optic at 100 Mbit/sUp to 10 km with 9 μm singlemode optic at 1000 Mbit/s

300 BAUD to 230.4 kBAUD (software configuration)

22

(up to 4000 m at derated temperature range)

Nominal voltage:

Nominal voltage:

2400 Ω

2 with common ground

Digital Output (for variants - 01 and - 02 only)

0 to 5 VDCMin. 2400 Ω

Mechanical Information

-40 to +85 °Cmax. 95% RH (non-condensing @ 40 °C)

250 ms

Permissible Ambient Conditions

Max. 2000 m above sea level

-30 to +60°C (fanless operation)

±0.5% of full scale

Up to 2 km

Multimode 62.5/125 μm or 50/125 μm

10 kbit/s - 1 Mbit/s

50 m

CANopen Communication Port

Port for RS232/RS422/RS485 Communication, SSI

I/O Capabilities (WP-Line 112 MK ll Gigabit Ethernet Switch/PSU - 01 and 02 only)

High Speed Counter Inputs (for variants - 01 and - 02 only)

Max. cable length

2

Up to 2 MHz

PT100 Inputs (for variants - 01 and - 02 only)

30 m @ 1 Mbit/s100 m @ 500 kbit/s500 m @ 125 kbit/s9-pin D-sub male (CiA 303)

Digital Inputs (for variants - 01 and - 02 only)

15 to 30 VDC0 to 5 VDC

0.05 Hz to 1k Hz

Analog Inputs (for variants - 01 and - 02 only)

Ethernet RJ45 Communication Port 10/100/1000 Mbit/s

For RS422 and RS485 mount 120 Ω at line ends6-pin 5.08 mm plugin terminal block with EARTH

Ethernet Optical Communication Port SC (not available for WP-Line 112 MK ll Gigabit Ethernet Switch/PSU - 01)

100 Mbit/s

1300 nm

EN 60068-2-27EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

170 x 166 x 65 mmMin. 25 mmApprox. 650 gIP30

Applied Standards

Supply Voltage

WP-Line BUS Supply

DIN-rail mounting

EN60068-2-78EN 60068-2-6EN 60068-2-27

RS422 max. 1200 meters @ 2 nodes RS485 max. 1200 meters @ 1.2K BAUDRS232 max. 30 mMulti wire cable with shield

Technical Data

Page 22: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 112 MK II Gigabit Ethernet Switch/PSU

MT_WP-Line 112 MK ll_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

NominalAllowed rangeCurrent consumption

Voltage delivered, nominal Allowed rangeDelivered current, maximum

Variant -01 -02 -03 -04Ethernet CopperEthernet Fibre Optic 4 x SFP 2 x SFP, 2 x SC 2 x SC 2 x SFP, 2 x SCSerial COM-PortCAN port

Communication speed, max.Max. cable length, examples

Connector

Communication speedRange, maximum recommended

Communication speedDistance

Communication speedFibre typeWave lengthDistance

No. of portsCommunication speedSSI clock frequency

Recommended cable typeTerminationConnector

Number of inputsGalvanic isolation

Signal "1"Signal "0"Input impedanceFrequency range

Number of inputsGalvanic isolation

Signal "1"Signal "0"Input impedanceMinimum pulsewidthSampling rate

Number of outputsOutput typeGalvanic isolationNominal voltageMaximum current

Number of inputsGalvanic isolationTemperature measuring rangeAccuracyResolutionCurrent for PT100 inputConversion time for each channel, max

Number of inputsGalvanic isolationInput currentAnalog bandwithAccuracyMeasurement resolutionInput resistance

Operation temperatureStorage temperatureRelative humidityOperation altitude

Dimensions (WxHxD)Required gap (top/bottom)WeightIngress Protection RatingMounting Method

Damp heatVibrationBumpShockTemperatureEMC

0.01 mA

*For load of individual modules, see specific technical manuals

500 V -40 to +211°C±0.5% of full scale0.1°CMax. 1 mA

2 with common ground

500 V

15 to 30 VDC

<200 Ω

4 with common ground500 V0 to 20 mA0 to 100 Hz

1NPN500 V24 V0.1 A

>20ms50 Hz

4 x RJ45

24 VDC18 to 30 VDC<0,3 A - 2,0 A

12 VDC11.5 to 12.75 VDC

BUS Port Connectors

3A/15 standard module loads*

2500 V

Ethernet Optical Communication Port SFP (not available for WP-Line 112 MK ll Gigabit Ethernet Switch/PSU - 03)

100/1000 Mbit/s

Up to 2 km with 50/62.5 μm multimode optic at 100 Mbit/sUp to 550 m with 50/125 μm multimode optic at 1000 Mbit/sUp to 40 km with 9 μm singlemode optic at 100 Mbit/sUp to 10 km with 9 μm singlemode optic at 1000 Mbit/s

300 BAUD to 230.4 kBAUD (software configuration)

22

(up to 4000 m at derated temperature range)

Nominal voltage:

Nominal voltage:

2400 Ω

2 with common ground

Digital Output (for variants - 01 and - 02 only)

0 to 5 VDCMin. 2400 Ω

Mechanical Information

-40 to +85 °Cmax. 95% RH (non-condensing @ 40 °C)

250 ms

Permissible Ambient Conditions

Max. 2000 m above sea level

-30 to +60°C (fanless operation)

±0.5% of full scale

Up to 2 km

Multimode 62.5/125 μm or 50/125 μm

10 kbit/s - 1 Mbit/s

50 m

CANopen Communication Port

Port for RS232/RS422/RS485 Communication, SSI

I/O Capabilities (WP-Line 112 MK ll Gigabit Ethernet Switch/PSU - 01 and 02 only)

High Speed Counter Inputs (for variants - 01 and - 02 only)

Max. cable length

2

Up to 2 MHz

PT100 Inputs (for variants - 01 and - 02 only)

30 m @ 1 Mbit/s100 m @ 500 kbit/s500 m @ 125 kbit/s9-pin D-sub male (CiA 303)

Digital Inputs (for variants - 01 and - 02 only)

15 to 30 VDC0 to 5 VDC

0.05 Hz to 1k Hz

Analog Inputs (for variants - 01 and - 02 only)

Ethernet RJ45 Communication Port 10/100/1000 Mbit/s

For RS422 and RS485 mount 120 Ω at line ends6-pin 5.08 mm plugin terminal block with EARTH

Ethernet Optical Communication Port SC (not available for WP-Line 112 MK ll Gigabit Ethernet Switch/PSU - 01)

100 Mbit/s

1300 nm

EN 60068-2-27EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

170 x 166 x 65 mmMin. 25 mmApprox. 650 gIP30

Applied Standards

Supply Voltage

WP-Line BUS Supply

DIN-rail mounting

EN60068-2-78EN 60068-2-6EN 60068-2-27

RS422 max. 1200 meters @ 2 nodes RS485 max. 1200 meters @ 1.2K BAUDRS232 max. 30 mMulti wire cable with shield

Technical Data

Mita-Teknik Ordering Information

Order Number Variant978011202 - 01-00-01

- 02-00-02- 03-00-03- 04-00-04

WP-Line 112 MK II Gigabit Ethernet Switch / PSU -03 2 X SCWP-Line 112 MK II Gigabit Ethernet Switch / PSU -04 2 X SC - 2 X SFP

Order NameWP-Line 112 MK II Gigabit Ethernet Switch / PSU -01 2 X SFP - 2 X SFP - I/OWP-Line 112 MK II Gigabit Ethernet Switch / PSU -02 2 X SC - 2 X SFP - I/O

Page 23: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 112 MK II Gigabit Ethernet Switch/PSU

MT_WP-Line 112 MK ll_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Configuration List

9788108 Serial Cable RS232 WP4x00 / Modem 2 m

Accessories

978800101 WP-Line Bus Flat Cable 27 mm molded

978810601 Serial Cable RS232 WP4x00 / N-Port 1.5 m

9788102 Serial Cable RS485 WP-Line 111/112/351 - WP4086 10 m9788103 Serial Cable RS485 WP-Line 111/112/351 - WP4059 2.5 m9788104

978800202 WP-Line Bus Terminator MK II

9788080 WP-Line 80 LED module

97891120103 Connection Kit Screw Black WP-Line 112 MK II – 03 & - 04

Fibre Optical Patch Cable 2X 62.5μm SC/SC-D 1 m

3389210 Ethernet Patch Cable 1 m

3370525

97891120101

Fibre Optical Patch Cable 2X 62.5μm SC/SC 2 m

3389220 Ethernet Patch Cable 2 m

33705153389250 Ethernet Patch Cable 5 m

1G Multimode Optic 50/125 μm (0.55 km) Transceiver

Serial Cable RS232 WP-Line 111/112/351 - DP9 male (UPS) 2 m9788105 Serial Cable RS232 WP-Line 111/112/351 - PC 2 m9788106 Serial Cable RS232 WP4x00 / N-Port 5 m

9788109 Serial Cable RS232 WP4x00 / PC 3 m

3370545 Fibre Optical Patch Cable 2X 62.5μm SC/SC-D 5 m

Connection Kit Screw Black WP-Line 112 MK II – 01 & - 02

3370537 Fibre Optical Patch Cable 2X 62.5 μm LC/LC-D 3 m3370547 Fibre Optical Patch Cable 2X 62.5 μm LC/LC-D 5 m2330500 Singlemode Optic 9 μm (40 km) Transceiver2330510 Multimode Optic 50/62.5 μm (2 km) Transceiver2330520 1G Singlemode Optic 9/125 μm (10 km) Transceiver2330530

Order NameLAN1-LAN4,

Mbit/sLAN5, LAN6,

Mbit/sLAN7, LAN8,

Mbit/sI/O

CapabilitiesWP-Line 112 MK II Gigabit Ethernet Switch/PSU - 01

10/100/1000, RJ45

100/1000, SFP1 100/1000, SFP1 2 x High Speed Counter Inputs2 x Digital Inputs1 x Digital Output2 x PT100 Inputs4 x Analog Inputs

WP-Line 112 MK II Gigabit Ethernet Switch/PSU - 02

10/100/1000, RJ45

100SC

100/1000, SFP1 2 x High Speed Counter Inputs2 x Digital Inputs1 x Digital Output2 x PT100 Inputs4 x Analog Inputs

WP-Line 112 MK II Gigabit Ethernet Switch/PSU - 03

10/100/1000, RJ45

100SC

NA NA

WP-Line 112 MK II Gigabit Ethernet Switch/PSU - 04

10/100/1000, RJ45

100SC

100/1000, SFP1NA

1SFP modules not included

Page 24: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 151 MK ll Grid Measurement

MT_WP-Line 151 MK ll_DataSheet_R8_0

®

© 2016 Mita-Teknik. All rights reserved

Specifications subject to change

› Realtime DSP grid measurement module

› Surveillance of 3 currents and 3 voltages › New, improved algorithms for precise, fast and reliable grid measurements

› Calculation of all grid data

› Grid protection

› Supports FRT/LVRT

› Supplies data for machine control

› Supplies data for production statistics

› Intelligent thermal control

› Configurable measuring modes to present Power, Energy and Powerfactor

The WP4x00 MK ll Control ConceptThe WP-Line 151 MK ll Grid Measurement module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security, and advanced data collection.

The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 151 MK llThe WP-Line 151 MK ll module has three voltage and three current analog inputs. The module is powered from the WP-Line BUS.

The WP4x00 MK ll controller can automatically update the programs via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network. Analog part is based on 16 bit precision ADC.

The WP-Line 151 MK ll module performs three basic functions:› Calculates main grid parameters› Switches turbine off the grid in case of grid fault› Provides WP4x00 MK ll controller with data

Main grid parameters like voltage, current, active and reactive powers, etc. are used by the WP4x00 control application for turbine overall control. Calculation of main grid parameters by precise and reliable DSP algorithms has the following features:› Frequency calculation algorithm assures measurement accuracy 0.01 Hz and higher› Voltage and currents are calculated using FFT algorithms› Powers and energies are measured according to IEC 61400-21 standard› Precise DSP algorithms and high update rate make support for FRT/LVRT

Page 25: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 151 MK ll Grid Measurement

MT_WP-Line 151 MK ll_DataSheet_R8_0

®

© 2016 Mita-Teknik. All rights reserved

Specifications subject to change

Apart from just measuring main grid parameters the WP-Line 151 MK II module can perform grid protection functions.In particular, it can protect the grid in case of the following grid faults:› Over/under voltage› Over/under average voltage› Over current› Over/under frequency› Over power› Reactive power high/voltage low› Vector jump› Rate of change of frequency (ROCOF) high

By default, the grid protection functionality of the WP-Line 151 MK ll module is disabled. For the WP-Line 151 MK ll module to perform grid protection functions it must be properly configured. The grid protection functionality of the WP-Line 151 MK ll module provides two level of grid protection:

› The first level is passive, that is, faults are only detected and registered but no active actions are undertaken.

› The second level is active, that is, when grid fault happens the relay is activated and thus the turbine is switched off the grid.

Furthermore, there is an option for manual relay activation regardless of grid faults state. Relay can be reset (closed) automatically, if voltage and frequency is within the specified range or manually. Grid protection by WP-Line 151 MK ll module operates with such definitions as threshold, dropout level and timeout.

› Threshold level defines a value crossing of which up or down – dependent on whether it is high or low threshold - leads to activation of ”timeout” timer.

› Dropout level defines a value crossing of which down or up – dependent on whether it is high or low threshold - leads to fault clearance.

› Timeout value defines time interval between crossing threshold and fault activation.

Once the relay is activated, it stays in this state during certain minimum period which is configurable value. There is an option for programmatical inversion of relay behavior - relay activation can be associated with either relay open or relay close state.

Fault reaction time, that is, time interval between fault detection and relay activation is configurable timeout value. If minimum reaction time is required then timeout is set to 0.

In case of voltage fault maximum relay reaction time is 30 ms. In case of frequency fault maximum relay reaction time is 50 ms.

Over/under voltage protection, over/under frequency protection and automatic relay closing are certified by TUV according to the BDEW 2008 standard. Certificate registration number is 44 797 15179701. The certificate is valid till 2021-03-14.

Page 26: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 151 MK ll Grid Measurement

MT_WP-Line 151 MK ll_DataSheet_R8_0

®

© 2016 Mita-Teknik. All rights reserved

Specifications subject to change

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical 0.40 AMaximum 0.45 AStandard module load 2

Typical 4.6 W

No. of current inputs 3Current input range 5 A RMSCurrent input impedance 10 mΩNo. of voltage inputs 3Voltage input range 18 V RMSVoltage input impedance 8.3 kΩResolution 16 bitAccuracy 0.2 % of full scaleSample speed 4 kHz

Max. switching current 1AMax. switching voltage 125 VDC/ACMax. response time 20 ms

Permissible Ambient ConditionsOperation temperature -30 to +60°C (fanless operation)Storage temperature -40 to +85 °CRelative humidity Max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min. 25 mmWeight 0.35 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Current Consumption (WP-Line BUS)

Grid Measurement Input

Relay output

Module Power Dissipation

Technical Data

Page 27: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 151 MK ll Grid Measurement

MT_WP-Line 151 MK ll_DataSheet_R8_0

®

© 2016 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Order Name978015102 WP-Line 151 MK ll Grid Measurement

Accessories9788080 WP-Line 80 LED module978800101 WP-Line BUS flat transmission cable, 27 mm molded 978800202 WP-Line BUS Terminator MK ll978915101 Connector Kit978802020 Cable WP-Line 151 - WP3090 2 m

Grid Measurement9723090 Grid Measurement Interface

Page 28: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 351 MK ll Combi I/O

MT_WP-Line 351 MK ll_DataSheet_R6_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 351 MK ll Combi I/O module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal opera-tion, high security, and advanced data collection. The concept typicaly consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 351 MK llThe WP-Line 351 MK ll Combi I/O module is equip-ped with 2 flexible COM-ports. COM1 can be configured to RS232/422/485 or SSI, COM2 can be configured to

RS422/485 or SSI via the software - as per requirement. The module also consists of various I/O‘s.

The digital I/O‘s are based on 24 Volt and consist of the following:› 16 high current digital solid state outputs› 26 digital inputs› 4 multi inputs: high speed input to 10 kHz or digital input

The analog section is based on 12 bit analog convertion and contains:› 4 flexible analog outputs that can be configured to -/+ 10 V or 0-20 mA as per requirement› 4 analog inputs, -/+10 V › 4 analog inputs, 0-20 mA › 8 PT100 inputs, - 60° to +230 °C› 2 multi inputs: thermistor with possibility of connecting more thermistors in series or as digital input

All I/O‘s are galvanic separated and all outputs are short-circuit protected. The WP4x00 MK ll controller automatically updates the program via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized I/O Combi module

› 2 serial COM-ports › 16 digital outputs/26 digital inputs/4 multi inputs: high speed counter - or digital input

› 4 analog outputs/8 analog inputs/8 PT100 inputs /2 multi inputs: thermistor or digital input

› Compact design

› Improved PT100 temperature range

› Improved PT100 accuracy

› Intelligent thermal control

Page 29: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 351 MK ll Combi I/O

MT_WP-Line 351 MK ll_DataSheet_R6_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical 0.25 AMaximum 0.30 AModule load 2

External Supply VoltageTypical 24 VDCMaximum 18 to 30 VDC

Typical 0.20 AMaximum 0.24 A

Typical 8.20 AMaximum 8.24 A

Typical 9.0 W

No. of points 26Isolation OptocouplerNominal voltage 24 VDCSignal “1” 15 to 30 VDCSignal “0” 0 to 5 VDCFrequency 0 to 50 Hz

No. of points 4Isolation OptocouplerNominal voltage 24 VDCMeasurement precision +/- 0.05%Signal “1” 15 to 30 VDCSignal “0” 0 to 5 VDCInput current/signal “1” +/- 16 mA (@ 24 V in)Input impedance 1.5 kΩInput frequency 0 to 10 kHz

Multi Input: Thermistor Input or Digital InputNo. of points 2Isolation OptocouplerSignal “1” >2800 Ω analog measurementSignal “0” <1300 Ω analog measurementInput frequency 0 to 4 Hz

Digital OutputNo. of points 16Number of groups 2Points per group 8Isolation OptocouplerOperation voltage 24 VDC +/- 2 VoltRated current per point Max. 500 mAMax. per group Max. 4 AOutput frequency 0 to 1 kHzShort-circuit protection Yes

No. of points 4Isolation OptocouplerInput configuration NoneInput voltage +/- 10 VMeasurement precision +/- 50mVInput frequency 0-100 HzResolution 12 bitInput impedance 37.5 kΩ

No. of points 4Isolation OptocouplerInput configuration NoneInput current 0-20 mAMeasurement precision +/- 50µAInput frequency 0-100 HzResolution 12 bitImput impedance 250 Ω

No. of points 8Isolation OptocouplerInput impedance 10 kΩ (PT100 current max. 1 mA)Resolution 12 bitAccuracy +/- 0.5 °CMeasuring range - 60 °C to 230 °C

Analog Voltage/Current OutputNo. of points 4Isolation OptocouplerOutput configuration Connection to interface

Setup as VoltageOutput voltage +/-10 V (10 mA @ RL = 1 kΩ)Output tolerance +/- 39mVResolution 12 bitOutput impedance 100 mΩShort-circuit protection Yes

Setup as CurrentOutput current 0 to 20 mA / max. 10 V @ RL = 500 ΩOutput tolerance +/- 39µAResolution 12 bit

No. of ports 1Isolation OptocouplerCommunication speed 300 BAUD to 230.4 kBAUD (software configuration)

RS422 max. 1200 m @ 2 nodes RS485 max. 1200 m @ 1.2K BAUDRS232 max. 30 m

Recommended cable type Multi wire cable with shieldTermination For RS422 and RS485 mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

No. of ports 1Isolation OptocouplerCommunication speed 300 BAUD to 230.4 kBAUD (software configuration)Max. cable length RS422 max. 1200 m @ 2 nodes

RS485 max. 1200 m @ 1.2 KBAUDRecommended cable type Multi wire cable with shieldTermination Mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

No. of ports 2 (shared with RS232/RS422/RS485)Isolation OptocouplerCommunication speed 70 kBAUDNumber of bits 1-32 (software configuration)Max. cable length 1200 mRecommended cable type Multi wire cable with shieldTermination Mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

Permissible Ambient ConditionsOperation temperature -30 to +60°C (fanless operation)Storage temperature -40 to +85 °CRelative humidity Max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 170 x 165 x 65 mmRequired gap (top/buttom) Min. 25 mmWeight 0.75 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Port for SSI Communication

Max. cable length

Analog Voltage Input

Digital Input

Multi Input: High Speed Input/Digital Input

Port for RS232/RS422/RS485 Communication

PT100 Input

Port for RS422/RS485 Communication

Analog Current Input

Current Consumption (WP-Line BUS)

Current Comsumption (External 24V Supply. Include Active Digital Output 0.5A x 16)

Module Power Dissipation (Without Active Digital Outputs)

Current Consumption (External 24V Supply. Exclude Active Digital Outputs)

Page 30: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 351 MK ll Combi I/O

MT_WP-Line 351 MK ll_DataSheet_R6_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical 0.25 AMaximum 0.30 AModule load 2

External Supply VoltageTypical 24 VDCMaximum 18 to 30 VDC

Typical 0.20 AMaximum 0.24 A

Typical 8.20 AMaximum 8.24 A

Typical 9.0 W

No. of points 26Isolation OptocouplerNominal voltage 24 VDCSignal “1” 15 to 30 VDCSignal “0” 0 to 5 VDCFrequency 0 to 50 Hz

No. of points 4Isolation OptocouplerNominal voltage 24 VDCMeasurement precision +/- 0.05%Signal “1” 15 to 30 VDCSignal “0” 0 to 5 VDCInput current/signal “1” +/- 16 mA (@ 24 V in)Input impedance 1.5 kΩInput frequency 0 to 10 kHz

Multi Input: Thermistor Input or Digital InputNo. of points 2Isolation OptocouplerSignal “1” >2800 Ω analog measurementSignal “0” <1300 Ω analog measurementInput frequency 0 to 4 Hz

Digital OutputNo. of points 16Number of groups 2Points per group 8Isolation OptocouplerOperation voltage 24 VDC +/- 2 VoltRated current per point Max. 500 mAMax. per group Max. 4 AOutput frequency 0 to 1 kHzShort-circuit protection Yes

No. of points 4Isolation OptocouplerInput configuration NoneInput voltage +/- 10 VMeasurement precision +/- 50mVInput frequency 0-100 HzResolution 12 bitInput impedance 37.5 kΩ

No. of points 4Isolation OptocouplerInput configuration NoneInput current 0-20 mAMeasurement precision +/- 50µAInput frequency 0-100 HzResolution 12 bitImput impedance 250 Ω

No. of points 8Isolation OptocouplerInput impedance 10 kΩ (PT100 current max. 1 mA)Resolution 12 bitAccuracy +/- 0.5 °CMeasuring range - 60 °C to 230 °C

Analog Voltage/Current OutputNo. of points 4Isolation OptocouplerOutput configuration Connection to interface

Setup as VoltageOutput voltage +/-10 V (10 mA @ RL = 1 kΩ)Output tolerance +/- 39mVResolution 12 bitOutput impedance 100 mΩShort-circuit protection Yes

Setup as CurrentOutput current 0 to 20 mA / max. 10 V @ RL = 500 ΩOutput tolerance +/- 39µAResolution 12 bit

No. of ports 1Isolation OptocouplerCommunication speed 300 BAUD to 230.4 kBAUD (software configuration)

RS422 max. 1200 m @ 2 nodes RS485 max. 1200 m @ 1.2K BAUDRS232 max. 30 m

Recommended cable type Multi wire cable with shieldTermination For RS422 and RS485 mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

No. of ports 1Isolation OptocouplerCommunication speed 300 BAUD to 230.4 kBAUD (software configuration)Max. cable length RS422 max. 1200 m @ 2 nodes

RS485 max. 1200 m @ 1.2 KBAUDRecommended cable type Multi wire cable with shieldTermination Mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

No. of ports 2 (shared with RS232/RS422/RS485)Isolation OptocouplerCommunication speed 70 kBAUDNumber of bits 1-32 (software configuration)Max. cable length 1200 mRecommended cable type Multi wire cable with shieldTermination Mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

Permissible Ambient ConditionsOperation temperature -30 to +60°C (fanless operation)Storage temperature -40 to +85 °CRelative humidity Max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 170 x 165 x 65 mmRequired gap (top/buttom) Min. 25 mmWeight 0.75 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Port for SSI Communication

Max. cable length

Analog Voltage Input

Digital Input

Multi Input: High Speed Input/Digital Input

Port for RS232/RS422/RS485 Communication

PT100 Input

Port for RS422/RS485 Communication

Analog Current Input

Current Consumption (WP-Line BUS)

Current Comsumption (External 24V Supply. Include Active Digital Output 0.5A x 16)

Module Power Dissipation (Without Active Digital Outputs)

Current Consumption (External 24V Supply. Exclude Active Digital Outputs)

Page 31: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 351 MK ll Combi I/O

MT_WP-Line 351 MK ll_DataSheet_R6_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical 0.25 AMaximum 0.30 AModule load 2

External Supply VoltageTypical 24 VDCMaximum 18 to 30 VDC

Typical 0.20 AMaximum 0.24 A

Typical 8.20 AMaximum 8.24 A

Typical 9.0 W

No. of points 26Isolation OptocouplerNominal voltage 24 VDCSignal “1” 15 to 30 VDCSignal “0” 0 to 5 VDCFrequency 0 to 50 Hz

No. of points 4Isolation OptocouplerNominal voltage 24 VDCMeasurement precision +/- 0.05%Signal “1” 15 to 30 VDCSignal “0” 0 to 5 VDCInput current/signal “1” +/- 16 mA (@ 24 V in)Input impedance 1.5 kΩInput frequency 0 to 10 kHz

Multi Input: Thermistor Input or Digital InputNo. of points 2Isolation OptocouplerSignal “1” >2800 Ω analog measurementSignal “0” <1300 Ω analog measurementInput frequency 0 to 4 Hz

Digital OutputNo. of points 16Number of groups 2Points per group 8Isolation OptocouplerOperation voltage 24 VDC +/- 2 VoltRated current per point Max. 500 mAMax. per group Max. 4 AOutput frequency 0 to 1 kHzShort-circuit protection Yes

No. of points 4Isolation OptocouplerInput configuration NoneInput voltage +/- 10 VMeasurement precision +/- 50mVInput frequency 0-100 HzResolution 12 bitInput impedance 37.5 kΩ

No. of points 4Isolation OptocouplerInput configuration NoneInput current 0-20 mAMeasurement precision +/- 50µAInput frequency 0-100 HzResolution 12 bitImput impedance 250 Ω

No. of points 8Isolation OptocouplerInput impedance 10 kΩ (PT100 current max. 1 mA)Resolution 12 bitAccuracy +/- 0.5 °CMeasuring range - 60 °C to 230 °C

Analog Voltage/Current OutputNo. of points 4Isolation OptocouplerOutput configuration Connection to interface

Setup as VoltageOutput voltage +/-10 V (10 mA @ RL = 1 kΩ)Output tolerance +/- 39mVResolution 12 bitOutput impedance 100 mΩShort-circuit protection Yes

Setup as CurrentOutput current 0 to 20 mA / max. 10 V @ RL = 500 ΩOutput tolerance +/- 39µAResolution 12 bit

No. of ports 1Isolation OptocouplerCommunication speed 300 BAUD to 230.4 kBAUD (software configuration)

RS422 max. 1200 m @ 2 nodes RS485 max. 1200 m @ 1.2K BAUDRS232 max. 30 m

Recommended cable type Multi wire cable with shieldTermination For RS422 and RS485 mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

No. of ports 1Isolation OptocouplerCommunication speed 300 BAUD to 230.4 kBAUD (software configuration)Max. cable length RS422 max. 1200 m @ 2 nodes

RS485 max. 1200 m @ 1.2 KBAUDRecommended cable type Multi wire cable with shieldTermination Mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

No. of ports 2 (shared with RS232/RS422/RS485)Isolation OptocouplerCommunication speed 70 kBAUDNumber of bits 1-32 (software configuration)Max. cable length 1200 mRecommended cable type Multi wire cable with shieldTermination Mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

Permissible Ambient ConditionsOperation temperature -30 to +60°C (fanless operation)Storage temperature -40 to +85 °CRelative humidity Max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 170 x 165 x 65 mmRequired gap (top/buttom) Min. 25 mmWeight 0.75 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Port for SSI Communication

Max. cable length

Analog Voltage Input

Digital Input

Multi Input: High Speed Input/Digital Input

Port for RS232/RS422/RS485 Communication

PT100 Input

Port for RS422/RS485 Communication

Analog Current Input

Current Consumption (WP-Line BUS)

Current Comsumption (External 24V Supply. Include Active Digital Output 0.5A x 16)

Module Power Dissipation (Without Active Digital Outputs)

Current Consumption (External 24V Supply. Exclude Active Digital Outputs)

Page 32: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 351 MK ll Combi I/O

MT_WP-Line 351 MK ll_DataSheet_R6_0

®

© 2018 Mita-Teknik. All rights reserved

Order Number Order Name978035102 WP-Line 351 MK ll Combi-1

Accessories9788080 WP-Line 80 LED Module978800101 WP-Line Bus Flat Cable 27 mm molded 978800202 WP-Line Bus Terminator MK ll9788102 Serial Cable RS485 WP-Line 111/351 - WP4086 10 m9788103 Serial Cable RS485 WP-Line 111/351 - WP4059 2.5 m9788104 Serial Cable RS232 WP-Line 111/351 - DP9 male (UPS) 2 m9788105 Serial Cable RS232 WP-Line 111/351 - PC 2 m978935101 Connector Kit Screw Black WP-Line 351 MK ll

Specifications subject to change

Technical Data

Mita-Teknik Ordering Information

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical 0.25 AMaximum 0.30 AModule load 2

External Supply VoltageTypical 24 VDCMaximum 18 to 30 VDC

Typical 0.20 AMaximum 0.24 A

Typical 8.20 AMaximum 8.24 A

Typical 9.0 W

No. of points 26Isolation OptocouplerNominal voltage 24 VDCSignal “1” 15 to 30 VDCSignal “0” 0 to 5 VDCFrequency 0 to 50 Hz

No. of points 4Isolation OptocouplerNominal voltage 24 VDCMeasurement precision +/- 0.05%Signal “1” 15 to 30 VDCSignal “0” 0 to 5 VDCInput current/signal “1” +/- 16 mA (@ 24 V in)Input impedance 1.5 kΩInput frequency 0 to 10 kHz

Multi Input: Thermistor Input or Digital InputNo. of points 2Isolation OptocouplerSignal “1” >2800 Ω analog measurementSignal “0” <1300 Ω analog measurementInput frequency 0 to 4 Hz

Digital OutputNo. of points 16Number of groups 2Points per group 8Isolation OptocouplerOperation voltage 24 VDC +/- 2 VoltRated current per point Max. 500 mAMax. per group Max. 4 AOutput frequency 0 to 1 kHzShort-circuit protection Yes

No. of points 4Isolation OptocouplerInput configuration NoneInput voltage +/- 10 VMeasurement precision +/- 50mVInput frequency 0-100 HzResolution 12 bitInput impedance 37.5 kΩ

No. of points 4Isolation OptocouplerInput configuration NoneInput current 0-20 mAMeasurement precision +/- 50µAInput frequency 0-100 HzResolution 12 bitImput impedance 250 Ω

No. of points 8Isolation OptocouplerInput impedance 10 kΩ (PT100 current max. 1 mA)Resolution 12 bitAccuracy +/- 0.5 °CMeasuring range - 60 °C to 230 °C

Analog Voltage/Current OutputNo. of points 4Isolation OptocouplerOutput configuration Connection to interface

Setup as VoltageOutput voltage +/-10 V (10 mA @ RL = 1 kΩ)Output tolerance +/- 39mVResolution 12 bitOutput impedance 100 mΩShort-circuit protection Yes

Setup as CurrentOutput current 0 to 20 mA / max. 10 V @ RL = 500 ΩOutput tolerance +/- 39µAResolution 12 bit

No. of ports 1Isolation OptocouplerCommunication speed 300 BAUD to 230.4 kBAUD (software configuration)

RS422 max. 1200 m @ 2 nodes RS485 max. 1200 m @ 1.2K BAUDRS232 max. 30 m

Recommended cable type Multi wire cable with shieldTermination For RS422 and RS485 mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

No. of ports 1Isolation OptocouplerCommunication speed 300 BAUD to 230.4 kBAUD (software configuration)Max. cable length RS422 max. 1200 m @ 2 nodes

RS485 max. 1200 m @ 1.2 KBAUDRecommended cable type Multi wire cable with shieldTermination Mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

No. of ports 2 (shared with RS232/RS422/RS485)Isolation OptocouplerCommunication speed 70 kBAUDNumber of bits 1-32 (software configuration)Max. cable length 1200 mRecommended cable type Multi wire cable with shieldTermination Mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

Permissible Ambient ConditionsOperation temperature -30 to +60°C (fanless operation)Storage temperature -40 to +85 °CRelative humidity Max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 170 x 165 x 65 mmRequired gap (top/buttom) Min. 25 mmWeight 0.75 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Port for SSI Communication

Max. cable length

Analog Voltage Input

Digital Input

Multi Input: High Speed Input/Digital Input

Port for RS232/RS422/RS485 Communication

PT100 Input

Port for RS422/RS485 Communication

Analog Current Input

Current Consumption (WP-Line BUS)

Current Comsumption (External 24V Supply. Include Active Digital Output 0.5A x 16)

Module Power Dissipation (Without Active Digital Outputs)

Current Consumption (External 24V Supply. Exclude Active Digital Outputs)

Page 33: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 411 MK ll PT100/PT1000 Input

MT_WP-Line 411 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 411 MK ll PT100/PT1000 Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal opera-tion, high security and advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 411 MK llThe WP-Line 411 MK ll PT100/PT1000 Input module has 16 x PT1000/PT100 inputs with extended temperature measur-ing range from -60 to +230 °C.

PT1000 or PT100 sensor mode is configured with software.

The module is powered from the WP-Line BUS. Software maintenance can be done onboard, even while the wind turbine is running/operating. All inputs are galvanic isolated from the system, have short circuit protection and sensor failure detection.

The WP4x00 MK ll controller automatically updates the pro-gram via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› 16 PT1000/PT100 inputs

› Max 1 mA current for each PT100 input › Max 0.33 mA current for each PT1000 input

› Temperature measuring range -60 to +230 °C

› Sensor failure output to WP4x00 controller

› Accuracy better than ±0.5 °C

› Designed for new cabinet, MK ll

› Data processing on module

Page 34: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 411 MK ll PT100/PT1000 Input

MT_WP-Line 411 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 – 13.5 VDC

Typical 200 mAMaximum 280 mAStandard module load 1

Typical 2.4 W

Number of inputs 16Isolation Galvanic isolationTemperature measuring range -60 to +230 °CAccuracy ±0.5 °CResolution 0.1 °CCurrent for PT100 input Max. 1 mACurrent for PT1000 input Max. 330 uAConversion time 250 ms data refresh rate

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/bottom) Min. 25 mmWeight 0.35 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Inputs

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Module Power Dissipation

Technical Data

Page 35: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 411 MK ll PT100/PT1000 Input

MT_WP-Line 411 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Order Name978041102 WP-Line 411 MK ll 16 X PT100/PT1000 Input

Accessories978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941101 Connector Kit Screw Black WP-Line 411

Page 36: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 412 MK ll PT100/PT1000 Input

MT_WP-Line 412 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 412 MK ll PT100/PT1000 Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal opera-tion, high security and advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 412 MK ll The WP-Line 412 MK ll PT100/PT1000 Input module has 32 x PT1000/PT100 inputs with extended temperature measuring range from -60 to +230 °C.

PT1000 or PT100 sensor mode is configured with software.

The module is powered from the WP-Line BUS. Software maintenance can be done onboard, even while the wind turbine is running/operating. All inputs are galvanic isolated from the system, have short circuit protection and sensor failure detection.

The WP4x00 MK ll controller automatically updates the pro-gram via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› 32 PT1000/PT100 inputs

› Max 1 mA current for each PT100 input › Max 0.33 mA current for each PT1000 input

› Temperature measuring range -60 to +230 °C

› Sensor failure output to WP4x00

› Accuracy better than ±0.5 °C

› Designed for new cabinet, MK ll

› Data processing on module

Page 37: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 412 MK ll PT100/PT1000 Input

MT_WP-Line 412 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 – 13.5 VDC

Typical 300 mAMaximum 450 mAStandard module load 2

Typical 3.6 W

Number of inputs 32Isolation Galvanic isolationTemperature measuring range -60 to +230 °CAccuracy ±0.5 °CResolution 0.1 °CCurrent for PT100 input Max. 1 mACurrent for PT1000 input Max. 330 uAConversion time 250 ms data refresh rate

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/bottom) Min. 25 mmWeight 0.45 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Module Power Dissipation

Inputs

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Page 38: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 412 MK ll PT100/PT1000 Input

MT_WP-Line 412 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Order Name978041202 WP-Line 412 MK ll 32 X PT100/PT1000 Input

Accessories978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941201 Connector Kit Screw Black WP-Line 412

Page 39: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 413 MK ll Analog Current Output

MT_WP-Line 413 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 413 MK ll Analog Current Output module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 413 MK ll The WP-Line 413 MK ll Analog Current Output module manages 16 x 0-20 mA software calibrated outputs.

The module is powered from the WP-Line BUS and 24 VDC external PSU. Software maintenance can be done onboard, even while the wind turbine is running/operating.

All outputs are galvanic separated from the CPU side and short-circuit protected. The WP4x00 MK llcontroller automatically updates the program via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

Analogue part is based on 12bit precision DAC.

› 16 current outputs

› 0 – 20 mA current range for each output › 3 kHz analogue bandwidth

› 12 bit DAC resolution

› Designed for new cabinet, MK ll

› Data processing on module

Page 40: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 413 MK ll Analog Current Output

MT_WP-Line 413 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 – 13.5 VDC

Typical 100 mAMaximum 160 mAStandard module load 1

Nominal 24 V, two supply pins for 8 analogue outputs eachAllowed range 19 – 30 VDC including ripple, max ripple ±2 V

Typical 100-200 mA, depends on the outputs stateMaximum 300 mA

Typical 4.7 W

Number of outputs 16Isolation Digital isolatorCurrent range 0 to 20 mAAccuracy ±39 uALoad resistance 0-500 OhmsDAC resolution 12 Bit (4.88uA/cnt)Analogue bandwidth 3 kHz

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/bottom) Min. 25 mmWeight 0.35 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Module Power Dissipation

Outputs

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

External Supply Voltage

Current Consumption (External Supply)

Page 41: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 413 MK ll Analog Current Output

MT_WP-Line 413 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Order Name978041302 WP-Line 413 MK ll 16 X 0-20 mA Current Output

Accessories978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941301 Connector Kit Screw Black WP-Line 413

Page 42: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 414 MK ll Combi

MT_WP-Line 414 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 414 MK ll Digital Input/Output, PT100/PT1000 Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 414 MK ll The WP-Line 414 MK ll Digital Input/Output, PT100/PT1000 Input module is equipped with both digital input/outputs

and PT100/PT1000 inputs.The digital I/O’s are based on 24 Volt and consist of the following:› 32 digital input› 16 digital output› Digital output: 24 VDC/0.5 Amp› Digital input: 24 VDC

The analog section contains:› 8 PT100/PT1000 inputs› Temperature masuring range from -60 to +230 °C › PT100 or PT1000 sensor mode is configured by software

Software maintenance can be done onboard, even while the wind turbine is running/operating. All I/O’s are galvanic separated from CPU system. All outputs are short circuit protected. PT100/PT1000 inputs have sensor failure detection.

The WP4x00 MK ll controller automatically updates the program via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized I/O combi module

› 32 digital input › Digital input voltage: 24 VDC

› 16 digital output

› Digital output voltage: 24 VDC/0.5 Amp

› 8 PT100/PT1000 inputs

› Temperature measuring range -60 to +230 °C

› Sensor failure output to WP4x00 MK ll controller

› Accuracy better than ± 0.5 °C

› Designed for new cabinets, MK ll

› Data processing on module

Page 43: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 414 MK ll Combi

MT_WP-Line 414 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 232 mAMaximum (all LED's on) 240 mAModule load 2

External Supply VoltageTypical 24 VDC. One connector for each 16 digital I/OMaximum 19 to 30 VDC

Typical 27 mAMaximum 35 mA

Typical 4.0 AmpMaximum 4.3 Amp

Typical (all inputs/outputs active) 5.0 WMaximum (all inputs/outputs active) 6.2 W

Number of input 32Number of groups 2Isolation Galvanic isolationInput Nominal voltage 24 VDCInput Signal "1" 15 to 30 VDCInput Signal "0" 0 to 5 VDCInput Frequency 0 to 50 Hz

Number of outputs 16Number of groups 1Output Voltage "1" 24 VDC (0.95 * Supply voltage)Output Voltage "0" 0 to 2 VDCOutput rated current per single output 0.5 Amp maxOutput current limit, totally 4.0 Amp max (16 outputs)Output short-circuit protection YesOutput frequency 0 to 500 Hz

Number of input 8Isolation Galvanic isolationTemperature measuring range -60 to +230 °CAccuracy ± 0.5 °CResolution 0.1 °CCurrent for PT100 input Max 1 mACurrent for PT1000 input Max 330 uAConversion time 250 ms data refresh rate

Current Consumption (External 24 V supply. Digital Inputs Active. Digital Outputs Inactive)

Current Consumption (External 24 V supply. Digital Outputs Active. Digital Inputs Inactive)

Module Power Dissipation

Digital Input

Digital Output

PT100 Input

Current Consumption (WP-Line BUS)

Page 44: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 414 MK ll Combi

MT_WP-Line 414 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Technical Data

Order Number Order Name978041402 WP-Line 414 MK ll 32 X Digital Input 16 X Digital Output

8 X PT100/PT1000 Input

Accessories9788080 WP-Line 80 LED module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941401 Connector Kit Screw Black WP-Line 414

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Permissible Ambient Conditions

Mechanical Information

Page 45: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 415 MK ll Analog Input

MT_WP-Line 415 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 415 MK ll Analog Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines- on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analogue/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 415 MK ll The WP-Line 415 MK ll Analog Input module manages 16x 0 - 20 mA and 16x 0 - 10V software calibrated inputs.

The module is powered from the WP-Line BUS. Software maintenance can be done on-site, even while the wind turbine is operating.

All inputs are galvanic separated from the CPU side and overvoltage protection. The WP4x00 MK ll controller automatically updates the program via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept. The analogue part is based on 16bit precision ADC.

› 32 analogue inputs

› 16 curent inputs, 0 – 20 mA for each input › 16 voltage inputs, 0 – 10V for each input

› 16 bit ADC resolution

› Accuracy better than ±0.15 % from full scale for current input and ±0.25 % from full scale for voltage input

› ≤300 Ohm input impedance for curent inputs and ≥10 kOhm for voltage inputs

› Designed for new cabinet, MK ll

Page 46: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 415 MK ll Analog Input

MT_WP-Line 415 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 – 13.5 VDC

Typical 240 mAMaximum 280 mAStandard module load 2

Typical 4.5 W

Number of inputs 16Isolation Digital isolatorCurrent range 0 to 20 mAAccuracy +/- 0.15% from full scaleLoad resistance ≤300 Ohm ADC resolution 16 bitAnalogue bandwidth 0 – 100 Hz

Number of outputs 16Isolation Digital isolatorVoltage range 0 - 10 VAccuracy +/- 0.25% from full scaleInput impedance ≥10 kOhmADC resolution 16 bit Analogue bandwidth 0 – 100 Hz

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Mechanical InformationDimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/bottom) Min. 25 mmWeight 0.35 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Current Inputs

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Voltage Inputs

Module Power Dissipation

Page 47: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 415 MK ll Analog Input

MT_WP-Line 415 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Order Name978041502 WP-Line 415 MK ll Analog Input module

Accessories978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941501 Connector Kit Screw Black WP-Line 415

Page 48: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 416 MK ll Digital Input

MT_WP-Line 416 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 416 MK ll Digital Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 416 MK ll The WP-Line 416 MK ll Digital Input module is equipped with 64 digital inputs.

The digital inputs are based on 24 Volt and consist of the following:› 64 digital input› Digital input: 24 VDC

Software maintenance can be done onboard, even while the wind turbine is running/operating. All inputs are galvanic separated from CPU system.

The WP4x00 MK ll controller automatically updates the program via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized input module

› 64 digital input › Digital input voltage: 24 VDC

› Designed for new cabinets, MK ll

› Data processing on module

Page 49: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 416 MK ll Digital Input

MT_WP-Line 416 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 160 mAMaximum (all LED's on) 200 mAModule load 1

External Supply VoltageTypical 24 VDC. One connector for each 16 digital inputMaximum 19 to 30 VDC

Typical 25 mAMaximum 35 mA

Typical (all inputs active) 5.0 WMaximum (all inputs active) 6.5 W

Number of input 64Number of groups 4Isolation Galvanic isolationInput Nominal voltage 24 VDCInput Signal "1" 15 to 30 VDCInput Signal "0" 0 to 5 VDCInput Frequency 0 to 50 Hz

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Current Consumption (External 24V supply. Digital Inputs Active)

Module Power Dissipation

Digital Input

Page 50: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 416 MK ll Digital Input

MT_WP-Line 416 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Order Name978041602 WP-Line 416 MK ll 64 X Digital Input

Accessories9788080 WP-Line 80 LED module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941601 Connector Kit Screw Black WP-Line 416

Page 51: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 417 MK ll Digital Output

MT_WP-Line 417 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 417 MK ll Digital Output module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 417 MK ll The WP-Line 417 MK ll Digital Output module is equipped with 64 digital outputs.

The digital outputs are based on 24 Volt and consist of the following:› 64 digital outputs› Digital output: 24 VDC/0.5 A

Software maintenance can be done onboard, even while the wind turbine is running/operating. All I/O’s are galvanic separated from the CPU system. All outputs are short circuit protected.

The WP4x00 MK ll controller automatically updates the software via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized output module

› 64 digital output › Digital output voltage: 24 VDC/0.5 A

› Designed for new cabinets, MK ll

› Data processing on module

Page 52: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 417 MK ll Digital Output

MT_WP-Line 417 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

Typical (all LED's on) 159 mAMaximum (all LED's on) 200 mAModule load 1

Typical 24 VDC. One connector for each 16 digital outputMaximum 19 to 30 VDC

Typical 16 AMaximum 17.2 A

Typical 48.2 mAMaximum 100 mA

Typical (all outputs active) 10.5 WMaximum (all outputs active) 12 W

Digital OutputNumber of outputs 64Number of groups 4Output Voltage "1" 24 VDC (0.95 * supply voltage)Output Voltage "0" 0 to 2 VDCOutput rated current per single output 0.5 A maxOutput current limit, totally 4 A pr. 16 outputs Output short-circuit protection YesOutput frequency 0 to 500 Hz

Operation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CMax. Relative humidity Max. 95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. Plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Permissible Ambient Conditions

External Supply Voltage

Construction

Current Consumption (WP-Line BUS)

Current Consumption (External 24 V supply. Digital Outputs Active)

Module Power Dissipation

Current Consumption (External 24 V supply. Digital Outputs InActive)

Page 53: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 417 MK ll Digital Output

MT_WP-Line 417 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Order Name978041702 WP-Line 417 MK ll 64 x Digital Output

Accessories9788080 WP-Line MK ll 80 LED Module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941701 Connector Kit Screw Black WP-Line 417

Page 54: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 418 MK ll Combi

MT_WP-Line 418 MK ll_DataSheet_R4_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 418 MK ll Digital Input/Output, Analog Current Input, PT100/PT1000 Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 418 MK ll The WP-Line 418 MK ll module is equipped with digital inputs, digital outputs, analog current inputs and PT100/

PT1000 inputs. The digital I/O’s are based on 24 Volt and consist of the following:› 16 digital inputs› Digital inputs voltage: 24 VDC› 16 digital outputs› Digital outputs voltage: 24 VDC/0.5 A

The analog section consist of the following: › 16 analog current inputs› 0 – 20 mA, with an accuracy better than ± 0.15% of full scale› 8 PT100/PT1000 inputs› Temperature measuring range -60 to +230 °C› PT100 or PT1000 sensor mode is configured by software

Software maintenance can be done onboard, even while the wind turbine is operating. All I/O’s are galvanic separated from the CPU system and all outputs are short circuit protected. The PT100/PT1000 inputs have sensor failure detection. The WP4x00 MK ll controller automatically updates the software via the network.

The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized I/O combi module

› 16 digital inputs › 16 digital outputs

› Digital output voltage: 24 VDC/0.5 A

› 16 analog current inputs 0 – 20 mA

› Analog Input over-current protection

› 8 PT100/PT1000 inputs

› Temperature measuring range -60 to +230 °C

› Sensor failure output to the WP4x00 MK ll controller

› Accuracy better than ±0.5 °C

› Designed for new cabinets, MK ll

› Data processing on module

Page 55: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 418 MK ll Combi

MT_WP-Line 418 MK ll_DataSheet_R4_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 232 mAMaximum (all LED's on) 240 mAModule load 2

External Supply VoltageTypical 24 VDC. One connector for each 16 digital I/OMaximum 19 to 30 VDC

Typical 21 mAMaximum 29 mA

Typical 4.0 AMaximum 4.3 A

Typical (all inputs/outputs active) 5.0 WMaximum (all inputs/outputs active) 6.2 W

Number of input 16Number of groups 1Isolation Galvanic isolationInput nominal voltage 24 VDCInput signal "1" 15 to 30 VDCInput signal "0" 0 to 5 VDCInput frequency 0 to 50 Hz

Number of outputs 16Number of groups 1Output voltage "1" 24 VDC (0.95 * supply voltage)Output voltage "0" 0 to 2 VDCOutput rated current per single output 0.5 A maxOutput current limit, totally 4.0 A max (16 outputs)Output short-circuit protection YesOutput frequency 0 to 500 Hz

Number of inputs 16Isolation Galvanic isolationover-current protection yes, up to 30VDCCurrent range 0 to 20 mAAccuracy +/- 0.15% of full scaleInput resistance ≤ 300 Ohm ADC resolution 16 bitAnalogue bandwidth 0 – 100 Hz

Number of input 8Isolation Galvanic isolationTemperature measuring range -60 to +230 °CAccuracy ± 0.5°CResolution 0.1°CCurrent for PT100 input Max 1 mACurrent for PT1000 input Max 330 uAConversion time 250 ms data refresh rate

Operation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CMax. relative humidity Max.95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

EMC EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

Current Consumption (External 24V supply. Digital Inputs Active. Digital Outputs Inactive)

Current Consumption (External 24V supply. Digital Outputs Active. Digital Inputs Inactive)

Module Power Dissipation

Digital Input

Digital Output

Current Inputs

PT100 Input

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Page 56: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 418 MK ll Combi

MT_WP-Line 418 MK ll_DataSheet_R4_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 232 mAMaximum (all LED's on) 240 mAModule load 2

External Supply VoltageTypical 24 VDC. One connector for each 16 digital I/OMaximum 19 to 30 VDC

Typical 21 mAMaximum 29 mA

Typical 4.0 AMaximum 4.3 A

Typical (all inputs/outputs active) 5.0 WMaximum (all inputs/outputs active) 6.2 W

Number of input 16Number of groups 1Isolation Galvanic isolationInput nominal voltage 24 VDCInput signal "1" 15 to 30 VDCInput signal "0" 0 to 5 VDCInput frequency 0 to 50 Hz

Number of outputs 16Number of groups 1Output voltage "1" 24 VDC (0.95 * supply voltage)Output voltage "0" 0 to 2 VDCOutput rated current per single output 0.5 A maxOutput current limit, totally 4.0 A max (16 outputs)Output short-circuit protection YesOutput frequency 0 to 500 Hz

Number of inputs 16Isolation Galvanic isolationover-current protection yes, up to 30VDCCurrent range 0 to 20 mAAccuracy +/- 0.15% of full scaleInput resistance ≤ 300 Ohm ADC resolution 16 bitAnalogue bandwidth 0 – 100 Hz

Number of input 8Isolation Galvanic isolationTemperature measuring range -60 to +230 °CAccuracy ± 0.5°CResolution 0.1°CCurrent for PT100 input Max 1 mACurrent for PT1000 input Max 330 uAConversion time 250 ms data refresh rate

Operation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CMax. relative humidity Max.95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

EMC EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

Current Consumption (External 24V supply. Digital Inputs Active. Digital Outputs Inactive)

Current Consumption (External 24V supply. Digital Outputs Active. Digital Inputs Inactive)

Module Power Dissipation

Digital Input

Digital Output

Current Inputs

PT100 Input

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Mita-Teknik Ordering Information

Order Number Order Name978041802 WP-Line 418 MK ll, 16x DIN, 16x DOUT, 16x AIN(I), 8x PT100/PT1000

Accessories9788080 WP-Line MK ll 80 LED Module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941801 Connector Kit Screw Black WP-Line 418

Page 57: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 419 MK ll Combi

MT_WP-Line 419 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 419 MK ll Combi module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines -on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection.

The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system withautomatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 419 MK ll The WP-Line 419 MK ll module is equipped with digital inputs, analog current outputs and analog current inputs.

The digital I/O’s are based on 24 volt and consist of the following:› 32 digital inputs› Digital inputs: 24 VDC

The analog section contains of:› 8 analog current outputs› 0 - 20mA, with an accuracy better than ±0.39 uA 16 analog current inputs› 16 analog current inputs› 0 - 20mA, with an accuracy better than ±0.15% of full scale

Software maintenance can be done onboard, even while the wind turbine is operating. All I/O’s are galvanic separated from CPU system and all outputs are short circuit protected.

The WP4x00 MK ll controller automatically updates the software via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized I/O combi module

› 32 digital inputs › 8 analog current outputs 0 - 20 mA

› 16 analog current inputs 0 - 20 mA

› Designed for new cabinets, MK ll

› Data processing on module

Page 58: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 419 MK ll Combi

MT_WP-Line 419 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 210 mAMaximum (all LED's on) 260 mAModule load 2

External Supply VoltageTypical 24 VDC. One connector for each 16 digital input

and 8 analog outputMaximum 19 - 30 VDC including ripple, max ripple ±2 V

Typical 12 mAMaximum 20 mA

Typical 140 mAMaximum 280 mA

Typical (all inputs/outputs active) 4.6 WMaximum (all inputs/outputs active) 8.7 W

Number of input 32Number of groups 2Isolation Galvanic isolationInput nominal voltage 24 VDCInput signal "1" 15 to 30 VDCInput signal "0" 0 to 5 VDCInput frequency 0 to 50 Hz

Number of outputs 8Isolation Digital isolatorCurrent range 0 to 20 mAAccuracy ±39 uALoad resistance 0-500 OhmsDAC resolution 12 Bit (4.88 uA/cnt)Analogue bandwidth 3 kHz

Number of inputs 16Isolation Galvanic isolationCurrent range 0 to 20 mAAccuracy +/- 0.15% of full scaleLoad resistance ≤300 Ohm ADC resolution 16 bitAnalogue bandwidth 0 – 100 Hz

Current Consumption (External 24V supply. Digital Inputs Active and Analog Outputs Inactive)

Current Consumption (External 24V supply. Digital Inputs Inactive and Analog Outputs @20mA)

Module Power Dissipation

Digital Input

Current Outputs

Current Inputs

Current Consumption (WP-Line BUS)

Page 59: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 419 MK ll Combi

MT_WP-Line 419 MK ll_DataSheet_R3_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Technical Data

Order Number Order Name978041902 WP-Line 419 MK ll Combi 32 X DIN 8 X AOUT (I) 16 X AIN (I)

Accessories9788080 WP-Line MK ll 80 LED Module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941901 Connector Kit Screw Black WP-Line 419

Operation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

EMC EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

Permissible Ambient Conditions

Mechanical Information

Page 60: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 420 MK ll Digital Input

MT_WP-Line 420 MK ll_DataSheet_R2_0

®

© 2014 Mita-Teknik. All rights reserved

The WP4x00 MK ll Control ConceptThe WP-Line 420 MK ll Digital Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 420 MK ll The WP-Line 420 MK ll Digital Input module is equipped with 16 digital inputs.

The digital inputs are based on 24 Volt and consist of the following:› 16 digital input› Digital input: 24 VDC

Software maintenance can be done onboard, even while the wind turbine is running/operating. All inputs are galvanic separated from CPU system.

The WP4x00 MK ll controller automatically updates the program via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized input module

› 16 digital input › Digital input voltage: 24 VDC

› Designed for new cabinets, MK ll

› Data processing on module

Page 61: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 420 MK ll Digital Input

MT_WP-Line 420 MK ll_DataSheet_R2_0

®

© 2014 Mita-Teknik. All rights reserved

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 73 mAMaximum (all LED's on) 89 mAModule load 1

External Supply VoltageTypical 24 VDC. One connector for each 16 digital inputMaximum 19 to 30 VDC

Typical 6 mAMaximum 10 mA

Typical (all inputs active) 1.6 WMaximum (all inputs active) 2.1 W

Number of input 16Number of groups 1Isolation Galvanic isolationInput Nominal voltage 24 VDCInput Signal "1" 15 to 30 VDCInput Signal "0" 0 to 5 VDCInput Frequency 0 to 50 Hz

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Current Consumption (External 24V supply. Digital Inputs Active)

Module Power Dissipation

Digital Input

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Page 62: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 420 MK ll Digital Input

MT_WP-Line 420 MK ll_DataSheet_R2_0

®

© 2014 Mita-Teknik. All rights reserved

Mita-Teknik Ordering Information

Order Number Order Name978042002 WP-Line 420 MK ll 16 X Digital Input

Accessories9788080 WP-Line 80 LED module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941601 Connector Kit Screw Black WP-Line 420

Page 63: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 421 MK ll Digital Input

MT_WP-Line 421 MK ll_DataSheet_R2_0

®

© 2014 Mita-Teknik. All rights reserved

The WP4x00 MK ll Control ConceptThe WP-Line 421 MK ll Digital Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 421 MK ll The WP-Line 421 MK ll Digital Input module is equipped with 32 digital inputs.

The digital inputs are based on 24 Volt and consist of the following:› 32 digital input› Digital input: 24 VDC

Software maintenance can be done onboard, even while the wind turbine is running/operating. All inputs are galvanic separated from CPU system.

The WP4x00 MK ll controller automatically updates the program via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized input module

› 32 digital input › Digital input voltage: 24 VDC

› Designed for new cabinets, MK ll

› Data processing on module

Page 64: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 421 MK ll Digital Input

MT_WP-Line 421 MK ll_DataSheet_R2_0

®

© 2014 Mita-Teknik. All rights reserved

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 106 mAMaximum (all LED's on) 122 mAModule load 1

External Supply VoltageTypical 24 VDC. One connector for each 16 digital inputMaximum 19 to 30 VDC

Typical 12 mAMaximum 20 mA

Typical (all inputs active) 2.7 WMaximum (all inputs active) 3.6 W

Number of input 32Number of groups 2Isolation Galvanic isolationInput Nominal voltage 24 VDCInput Signal "1" 15 to 30 VDCInput Signal "0" 0 to 5 VDCInput Frequency 0 to 50 Hz

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Current Consumption (External 24V supply. Digital Inputs Active)

Module Power Dissipation

Digital Input

Page 65: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 421 MK ll Digital Input

MT_WP-Line 421 MK ll_DataSheet_R2_0

®

© 2014 Mita-Teknik. All rights reserved

Mita-Teknik Ordering Information

Order Number Order Name978042102 WP-Line 421 MK ll 32 X Digital Input

Accessories9788080 WP-Line 80 LED module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941601 Connector Kit Screw Black WP-Line 421

Page 66: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 422 MK ll Digital Input

MT_WP-Line 422 MK ll_DataSheet_R2_0

®

© 2014 Mita-Teknik. All rights reserved

The WP4x00 MK ll Control ConceptThe WP-Line 422 MK ll Digital Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 422 MK ll The WP-Line 422 MK ll Digital Input module is equipped with 48 digital inputs.

The digital inputs are based on 24 Volt and consist of the following:› 48 digital input› Digital input: 24 VDC

Software maintenance can be done onboard, even while the wind turbine is running/operating. All inputs are galvanic separated from CPU system.

The WP4x00 MK ll controller automatically updates the program via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized input module

› 48 digital input › Digital input voltage: 24 VDC

› Designed for new cabinets, MK ll

› Data processing on module

Page 67: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 422 MK ll Digital Input

MT_WP-Line 422 MK ll_DataSheet_R2_0

®

© 2014 Mita-Teknik. All rights reserved

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 139 mAMaximum (all LED's on) 155 mAModule load 1

External Supply VoltageTypical 24 VDC. One connector for each 16 digital inputMaximum 19 to 30 VDC

Typical 18 mAMaximum 30 mA

Typical (all inputs active) 3.9 WMaximum (all inputs active) 5.0 W

Number of input 48Number of groups 3Isolation Galvanic isolationInput Nominal voltage 24 VDCInput Signal "1" 15 to 30 VDCInput Signal "0" 0 to 5 VDCInput Frequency 0 to 50 Hz

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Current Consumption (External 24V supply. Digital Inputs Active)

Module Power Dissipation

Digital Input

Page 68: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 422 MK ll Digital Input

MT_WP-Line 422 MK ll_DataSheet_R2_0

®

© 2014 Mita-Teknik. All rights reserved

Mita-Teknik Ordering Information

Order Number Order Name978042202 WP-Line 422 MK ll 48 X Digital Input

Accessories9788080 WP-Line 80 LED module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978941601 Connector Kit Screw Black WP-Line 422

Page 69: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 423 MK ll Digital Input

MT_WP-Line 423 MK ll_DataSheet_R3_0

®

© 2017 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 423 MK ll Digital Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 423 MK ll The WP-Line 423 MK ll Digital Input module is equipped with 64 digital inputs.

The digital inputs are based on 24 Volt and consist of the following:› 64 digital input› Digital input: 24 VDC

Software maintenance can be done onboard, even while the wind turbine is running/operating. All inputs are galvanic separated from CPU system.

The WP4x00 MK ll controller automatically updates the program via the network. The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized input module

› 64 digital input › Digital input voltage: 24 VDC

› Designed for new cabinets, MK ll

› Data processing on module

Page 70: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 423 MK ll Digital Input

MT_WP-Line 423 MK ll_DataSheet_R3_0

®

© 2017 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 160 mAMaximum (all LED's on) 200 mAModule load 1

External Supply VoltageTypical 24 VDC. One connector for each 16 digital inputMaximum 19 to 30 VDC

Typical 25 mAMaximum 35 mA

Typical (all inputs active) 5.0 WMaximum (all inputs active) 6.5 W

Number of input 64Number of groups 4Isolation Galvanic isolationInput Nominal voltage 24 VDCInput Signal "1" 15 to 30 VDCInput Signal "0" 0 to 5 VDCInput Frequency 0 to 50 Hz

Operation temperature -30 to 60 °C (fanless operation)Storage temperature -40 to 85 °CRelative humidity Max. 95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Current Consumption (External 24V supply. Digital Inputs Active)

Module Power Dissipation

Digital Input

Page 71: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 423 MK ll Digital Input

MT_WP-Line 423 MK ll_DataSheet_R3_0

®

© 2017 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Order Name978042302 WP-Line 423 MK ll 64 x Digital Input

Accessories9788080 WP-Line 80 LED module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978942301 Connector Kit Screw Black WP-Line 423 MK II

Page 72: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 424 MK ll

MT_WP-Line 424 MK ll_DataSheet_R2_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 424 MK ll Digital Input/Output module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines on– and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and advanced data collection.

The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 424 MK ll The WP-Line 424 MK ll module is equipped with digital inputs and digital outputs. The digital I/O’s are based on 24 Volt and consist of the following: › 32 digital inputs› Digital input voltage: 24 VDC› 16 digital outputs› Digital output voltage: 24 VDC/0.5 A

Software maintenance can be done onboard, even while the wind turbine is operating. All I/O’s are galvanic separated from the CPU system and all outputs are short circuit protected. The WP4x00 MK ll controller automatically updates the software via the network.

The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized I/O combi module

› 32 digital input › Digital input voltage: 24 VDC

› 16 digital output

› Digital output voltage: 24 VDC/0.5 Amp

› Designed for new cabinets, MK ll

› Data processing on module

Page 73: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 424 MK ll

MT_WP-Line 424 MK ll_DataSheet_R2_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 232 mAMaximum (all LED's on) 240 mAModule load 2

External Supply VoltageTypical 24 VDC. One connector for each 16 digital I/OMaximum 19 to 30 VDC

Typical 21 mAMaximum 29 mA

Typical 4.0 AMaximum 4.3 A

Typical (all inputs/outputs active) 5.0 WMaximum (all inputs/outputs active) 6.2 W

Number of input 32Number of groups 2Isolation Galvanic isolationInput nominal voltage 24 VDCInput signal "1" 15 to 30 VDCInput signal "0" 0 to 5 VDCInput frequency 0 to 50 Hz

Number of outputs 16Number of groups 1Output voltage "1" 24 VDC (0.95 * supply voltage)Output voltage "0" 0 to 2 VDCOutput rated current per single output 0.5 A maxOutput current limit, totally 4.0 A max (16 outputs)Output short-circuit protection YesOutput frequency 0 to 500 Hz

Operation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CMax. relative humidity Max.95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

EMC EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

Current Consumption (External 24V supply. Digital Inputs Active. Digital Outputs Inactive)

Current Consumption (External 24V supply. Digital Outputs Active. Digital Inputs Inactive)

Module Power Dissipation

Digital Input

Digital Output

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Page 74: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 424 MK ll

MT_WP-Line 424 MK ll_DataSheet_R2_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Technical Data

Order Number Order Name978042402 WP-Line 424 MK II 32 x DIN 16 x DOUT

Accessories9788080 WP-Line MK ll 80 LED Module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978942401 Connector Kit Screw Black WP-Line 424

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 232 mAMaximum (all LED's on) 240 mAModule load 2

External Supply VoltageTypical 24 VDC. One connector for each 16 digital I/OMaximum 19 to 30 VDC

Typical 21 mAMaximum 29 mA

Typical 4.0 AMaximum 4.3 A

Typical (all inputs/outputs active) 5.0 WMaximum (all inputs/outputs active) 6.2 W

Number of input 32Number of groups 2Isolation Galvanic isolationInput nominal voltage 24 VDCInput signal "1" 15 to 30 VDCInput signal "0" 0 to 5 VDCInput frequency 0 to 50 Hz

Number of outputs 16Number of groups 1Output voltage "1" 24 VDC (0.95 * supply voltage)Output voltage "0" 0 to 2 VDCOutput rated current per single output 0.5 A maxOutput current limit, totally 4.0 A max (16 outputs)Output short-circuit protection YesOutput frequency 0 to 500 Hz

Operation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CMax. relative humidity Max.95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

EMC EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

Current Consumption (External 24V supply. Digital Inputs Active. Digital Outputs Inactive)

Current Consumption (External 24V supply. Digital Outputs Active. Digital Inputs Inactive)

Module Power Dissipation

Digital Input

Digital Output

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Page 75: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 425 MK ll

MT_WP-Line 425 MK ll_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 425 MK ll Digital Input/Output, Analog Current Input module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and, advanced data collection. The concept typically consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Robust WP-Line interconnection› Fast and easy DIN-rail mounting› Automatic node assignment of WP-Line modules› Simplified module status indication› Supports removable LED matrix display› Service-friendly

The WP-Line 425 MK ll The WP-Line 425 MK ll module is equipped with digital inputs, digital outputs and analog current inputs. The digital I/O’s are based on 24 Volt and consist of the following:› 32 digital inputs› Digital inputs: 24 VDC› 16 digital outputs› Digital outputs: 24 VDC/0.5 A

The analog section contains of: › 16 analog current inputs› 0 – 20 mA, with an accuracy better than ± 0.15% of full scale

Software maintenance can be done onboard, even while the wind turbine is operating. All I/O’s are galvanic separated from the CPU system and all outputs are short circuit protected. The WP4x00 MK ll controller automatically updates the software via the network.

The communication to the WP4x00 MK ll controller is event-based, which means that only changed values are transmitted via the network.

Plug-and-play connection to the WP4x00 MK ll Control Concept.

› Optimized I/O combi module

› 32 digital inputs

› Digital input voltage: 24 VDC › 16 digital outputs

› Digital output voltage: 24 VDC/0.5 A

› 16 analog current inputs 0 – 20 mA

› Designed for new cabinets, MK ll

› Data processing on module

Page 76: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 425 MK ll

MT_WP-Line 425 MK ll_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 232 mAMaximum (all LED's on) 240 mAModule load 2

External Supply VoltageTypical 24 VDC. One connector for each 16 digital I/OMaximum 19 to 30 VDC

Typical 21 mAMaximum 29 mA

Typical 4.0 AMaximum 4.3 A

Typical (all inputs/outputs active) 5.0 WMaximum (all inputs/outputs active) 6.2 W

Number of input 32Number of groups 2Isolation Galvanic isolationInput nominal voltage 24 VDCInput signal "1" 15 to 30 VDCInput signal "0" 0 to 5 VDCInput frequency 0 to 50 Hz

Number of outputs 16Number of groups 1Output voltage "1" 24 VDC (0.95 * supply voltage)Output voltage "0" 0 to 2 VDCOutput rated current per single output 0.5 A maxOutput current limit, totally 4.0 A max (16 outputs)Output short-circuit protection YesOutput frequency 0 to 500 Hz

Number of inputs 16Isolation Galvanic isolationCurrent range 0 to 20 mAAccuracy +/- 0.15% of full scaleLoad resistance ≤300 Ohm ADC resolution 16 bitAnalogue bandwidth 0 – 100 Hz

Operation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CMax. relative humidity Max.95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

EMC EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Digital Output

Current Inputs

Current Consumption (External 24V supply. Digital Inputs Active. Digital Outputs Inactive)

Current Consumption (External 24V supply. Digital Outputs Active. Digital Inputs Inactive)

Module Power Dissipation

Digital Input

Page 77: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 425 MK ll

MT_WP-Line 425 MK ll_DataSheet_R1_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering InformationOrdering data is provisional. For more details please contact Mita-Teknik.

Technical Data

WP-Line BUS Supply VoltageNominal 12 VDCAllowed range 10.5 to 13.5 VDC

Typical (all LED's on) 232 mAMaximum (all LED's on) 240 mAModule load 2

External Supply VoltageTypical 24 VDC. One connector for each 16 digital I/OMaximum 19 to 30 VDC

Typical 21 mAMaximum 29 mA

Typical 4.0 AMaximum 4.3 A

Typical (all inputs/outputs active) 5.0 WMaximum (all inputs/outputs active) 6.2 W

Number of input 32Number of groups 2Isolation Galvanic isolationInput nominal voltage 24 VDCInput signal "1" 15 to 30 VDCInput signal "0" 0 to 5 VDCInput frequency 0 to 50 Hz

Number of outputs 16Number of groups 1Output voltage "1" 24 VDC (0.95 * supply voltage)Output voltage "0" 0 to 2 VDCOutput rated current per single output 0.5 A maxOutput current limit, totally 4.0 A max (16 outputs)Output short-circuit protection YesOutput frequency 0 to 500 Hz

Number of inputs 16Isolation Galvanic isolationCurrent range 0 to 20 mAAccuracy +/- 0.15% of full scaleLoad resistance ≤300 Ohm ADC resolution 16 bitAnalogue bandwidth 0 – 100 Hz

Operation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CMax. relative humidity Max.95% at 40 °COperation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

Dimensions (WxHxD) 85 x 165 x 65 mmRequired gap (top/buttom) Min 25 mmWeight 0.50 Kg (incl. plug in terminal blocks)Degree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14

EMC EN 61000-6-2 (Immunity standard for industrial environments)EN 61000-6-4 (Emission standard for industrial environments)

Permissible Ambient Conditions

Current Consumption (WP-Line BUS)

Mechanical Information

Digital Output

Current Inputs

Current Consumption (External 24V supply. Digital Inputs Active. Digital Outputs Inactive)

Current Consumption (External 24V supply. Digital Outputs Active. Digital Inputs Inactive)

Module Power Dissipation

Digital Input

Order Number Order Name978042502 WP-Line 425 MK II 32x DIN, 16x DOUT, 16x AIN(I)

Accessories9788080 WP-Line MK ll 80 LED Module978800101 WP-Line BUS Flat Cable 27 mm Molded978800202 WP-Line MK ll BUS Terminator978942501 Connector Kit Screw Black WP-Line 425

Page 78: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 511 MK ll CANopen Interface

MT_WP-Line 511 MK ll_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP-Line 511 MK ll CANopen interface module is part of the WP4x00 MK ll Control Concept which has been specially designed to control large wind turbines - on- and offshore. The WP4x00 MK ll Control Concept ensures optimal operation, high security and advanced data collection.

The concept typical consists of a power supply/backbone module, a WP4x00 MK ll controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 MK ll Con-trol Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detecting and error reporting.

Advantages of the WP4x00 MK ll Control Concept:› Corrosion robust construction› Fast and easy DIN-rail mounting› Simplified module status indication› Service-friendly

The WP-Line 511 MK llHigh speed Ethernet to CANopen Master interface designed for stand alone operation and as a part of the WP4x00 MK ll Control Concept.

Internal 10/100 Ethernet switch for routing and interfacing. Backbone Ethernet communication can be connected with

optic fibre cables as double ring with one spare fibre cable for backup. This setup provides high communication safety, as this con-figuration allows operation despite of a defect optic fiber. The optic fibre cable type is 62.5/125μm or 50/125μm. Additional 2 x 10/100 Ethernet (RJ45) are on the module. Up to 1MBit/s CANopen Master communication to other CANopen based devices. Galvanic isolated CANbus interface.

Internal condition monitoring, 7-segment display showing group number and 3-LED status indication facilitates fast servicing.

Automatic firmware update is managed by the WP4x00 MK ll controller.

The module can easily be programmed as a CANopen Master, interfacing WP4x00 MK ll controller to any CANopen device (frequency Converter, Pitch controller, etc.). Via generic CAN-open application (in compliance with CiA301 and CiA DSP 302 specification standards) and user-friendly interface of Mita-Teknik “CANopen Configuration Tool” all CANopen network parameters can be easily configured and adjusted to meet the preset requirements.

The module supports Layer Setting Services (LSS) according to CANopen specification CiA DS-305.

› Stand-alone Ethernet to CANopen Master Interface, designed for the WP4x00 concept

› Up to 1Mbit/s CANopen

› CANopen LSS Support › 2 x Ethernet 100 Base-FX (SC Optic Backbone with redundant option)

› 2 x RJ45 Ethernet 10/100 for display and service

› Flexible serial COM-Port (RS232/RS422/RS485)

› Supports removable LED matrix display

› +24 VDC supply voltage

› Intelligent thermal control

Page 79: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 511 MK ll CANopen Interface

MT_WP-Line 511 MK ll_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

Supply VoltageNominal 24 VDCAllowed range 18 to 30 VDCPower consumption max 7.2 W

CANopen 1Ethernet 2 x RJ45Ethernet 2 x SCSerial COM-port 1

Communication speed, max 10 kbit/s - 1 mbit/s30 m @ 1 mbit/s100 m @ 500 kbit/s500 m @ 125 kbit/s

Connector 9-pin D-sub male (CiA 303)

Communication speed 10/100 mbit/sMax. cable length 50 m

Communication speed 10/100 mbit/sWave length 1300 nmConnector SCFibre types 50/100 μm 62.5/125 μmOutput Optical Power -23.5 dBm avg. -20 dBm avg.Input Optical Power Minimum -31 dBm avg. -31 dBm avg.Max. BBN cable length at -1.5 dBm/km 2000 m 4000 m(incl. -4.5 dBm loss from up to 6 fibre cable connections)

Isolation Digital isolatorCommunication speed 9.6 kBAUD to 230.4 kBAUD (software configuration)

RS422 max. 1200 m @ 2 nodes RS485 max. 1200 m @ 9.6 kBAUD

RS232 max. 30 m

Recommended cable type Multi wire cable with shieldTermination For RS422 and RS485 mount 120 Ω at line endsConnector 6-pin 5.08 mm plugin terminal block with EARTH

Permissible Ambient ConditionsOperation temperature -30 to +60°C (fanless operation)Storage temperature -40 to 85 °CRelative humidity max. 95% RH (non-condensing @ 40 °C)Operation altitude Max. 2000 m above sea level

(up to 4000 m at derated temperature)

BUS Port Connectors

Port for RS232/RS422/RS485 Communication

Max. cable length

CANopen Communication Port

Max. cable length, examples

ETHERNET RJ45 Communication Port

ETHERNET Optical Communication Port

Page 80: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP-Line 511 MK ll CANopen Interface

MT_WP-Line 511 MK ll_DataSheet_R7_0

®

© 2017 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Technical Data

Mechanical InformationDimensions (W x H x D) 85 x 165 x 65 mmRequired gap (top/bottom) Min. 25 mmWeight 325 gDegree of protection IP30

Applied StandardsDamp heat EN60068-2-78Vibration EN 60068-2-6Bump EN 60068-2-27Shock EN 60068-2-27Temperature EN 60068-2-1, EN 60068-2-2 and EN 60068-2-14EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Order Number Order Name978051102 WP-Line 511 MK ll Backbone CANopen

Accessories9788080 WP-Line 80 LED module9728106 Data Cable for CAN/CAN Interface 3.0 m with Female Connector UL9728109 Data Cable CAN/CAN Interface 2 x 3.0m with Female Connector9728108 Data Cable for CAN/CAN Interface 3.0 m with Male & Female

Connector UL9788106 Serial Cable RS232 WP4x00/N-Port 5 m978810601 Serial Cable RS232 WP4x00/N-Port 1.5 m9788108 Serial Cable RS232 WP4x00/Modem 2 m9788109 Serial Cable RS232 WP4x00/PC 3 m3389210 Ethernet Patch Cable RJ45 1 m3389220 Ethernet Patch Cable RJ45 2 m 3389250 Ethernet Patch Cable RJ45 5 m3310060 Gender Changer DB9 Female-Female3370515 Fibre Optical Patch Cable 2 x 62.5μm SC/SC 1 m3370525 Fibre Optical Patch Cable 2 x 62.5μm SC/SC 2 m3370545 Fibre Optical Patch Cable 2 x 62.5μm SC/SC 5 m978951101 Connector Kit Screw Black WP-Line 511

Page 81: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4052 Touch Display

MT_WP4052_DataSheet_R2_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4x00 MK ll Control ConceptThe WP4052 Graphic Color Touch Screen Display is used with the WP4x00 Control Concept and provide access to the wind turbine. The WP4x00 Control Concept has been specially designed to control large wind turbines - on- and offshore. The WP4x00 Control Concept ensures optimal operation, high security, and advanced data collection.

The concept typically consists of a power supply/backbone module, a WP4x00 controller, a grid measurement module as well as an analog/digital I/O module dependent on the specific configuration task. The WP4x00 Control Concept makes it possible to have redundant solutions. The concept is constructed as a plug-and-play system with automatic module detection and error reporting.

The WP4052 Touch DisplayA touch screen with the possibility of on screen keyboard and a display with resolution of 1024 x 768, 16 bit colours. Operating system with WEB browser for fast and user-friendly operation. The panel is mainly designed for panel mount application. It is also possible to connecting more displays per controller.

Furthermore, the WP4052 display offers: › Ethernet system connection› USB port in front› Sleepmode/screen saver

› Condensation and salt resistant› Degree of protection IP55› User-friendly 3 LED status› Maintenance free (no fan or battery)› Fast response time, 1.6GHz proccesor

Cold Climate VersionThe WP4052 is also available in a cold climate version with internal heater for cold climate operation.

Access and Maintenance Second to none control of wind turbines. Software main-tenance even while the wind turbine is running - by use of JAVA applets from the WP4x00 controller.

› Touch screen graphic display for the WP4x00 Control Concept

› 15” TFT with 1024 x 768 resolution, 16 bit colours › USB Port in front

› Quick and reliable survey of functions and data in the wind turbine

› Maximum user comfort via the HMI principle

› User-friendly menu structure

› Designed for easy mounting

› Pressure sensitive touch screen; responds to finger, gloved hand or pen

Page 82: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4052 Touch Display

MT_WP4052_DataSheet_R2_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

External Supply VoltageTypical 24 VDCMaximum 19 to 30 VDC

Typical 1.0 AMaximum 1.3 A @19 VDC

Typical 1.0 AMaximum 1.3 A @19 VDC

Typical 4.3 AMaximum 5.0 A @ 30 VDC

Typical 24 W

Size 15 "Resolution 1024 x 768Colour resolution 16 bit

Maximum 75 sec.

Ambient temperature > 0 °C 75 sec.

Current Consumption (External 24V Supply) Cold Climate Version (Ambient temperature > 0 °C)

Start-up Time, Basic Version

Display

Current Comsumption (External 24V Supply) Cold Climate Version (Ambient temperature < 0 °C)

Module Power Dissipation (Without Active Heating Element)

Current Consumption (External 24V Supply) Basic Version

Start-up Time, Cold Climate Version

Mounting Measurements

Technical Data

Recommended panel cut out

Page 83: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4052 Touch Display

MT_WP4052_DataSheet_R2_0

®

© 2015 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Order Number Order Name978405201 WP4052 Touch Display - Basic Mita-Teknik978405202 WP4052 Touch Display - Cold Climate Mita-Teknik

Accessories3389210 Ethernet Patch Cable RJ45, STP, Grey, 1.0 meter3389220 Ethernet Patch Cable RJ45, STP, Grey, 2.0 meter3389250 Ethernet Patch Cable RJ45, STP, Grey, 5.0 meter

Ambient temperature < 0 °C < 30 min.

Communication speed 10/100 Mbit/sMax. cable length 50 m

Permissible Ambient ConditionsOperation temperature Basic version Front (Outside control panel) -30 to +60 °C Back (Inside control panel) 0 to +60 °C Cold climate version -40 to +60 °CTransportation/Storage temperature -40 to +85 °CMax. relative humidity Max. 95% RH (non-condensing @ 40 °C)Max. operation height 2000 m. above sea level (higher levels only by special

agreement with Mita-Teknik)

ConstructionDimensions (WxHxD) 400 x 340 x 72 mmCutout Dimensions (WxHxD) 364 x 304 x (62) mmWeight 4.50 Kg

Degree of ProtectionDegree of protection (front) IP55Degree of protection (back) IP20Standards EN61000-6-2 (CE)

EN61000-6-4 (CE)EN61000-4-5 (Surge)

Ethernet RJ45 Communication Port

Technical Data

Page 84: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4053

MT_WP4053_DataSheet_R5_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

The WP4053 The WP4053 Graphic Color Touch Screen Display is used with Mita-Teknik Control System and provides access to the wind turbine. The display is compatible with WP4x00, WP100 and WP3x00 MK II Control Platforms. It gives possibility to start/stop the wind turbine, gives access to diagnostic information, parameters changing and troubleshooting. It is perfect solution for cost-optimized systems and where size of the display is one of the crucial factors. It’s also provided with an industrial operating temperature range to fulfil the requirements of harsh environments.

FeaturesA touch screen with the possibility of on screen keyboard and a display with resolution of 800 x 480, 16 bit colours. LINUX operating system with WEB browser for fast and user-friendly operation. The panel is mainly designed for panel mount application. Possibility of connecting more displays per controller. ETHERNET system connection. USB Port on back side.

Access and Maintenance Second to none control of wind turbines. Software maintenance even while the wind turbine is running - by use of JAVA applets from the Mita-Teknik controller.

› Touch Screen Graphic Display for the Mita-Teknik Control System

› 7” TFT with 800 x 480 resolution, 16 bit colours › USB Port

› Front panel IP66 compliant

› Quick and reliable survey of functions and data in the wind turbine

› Maximum user comfort via the HMI principle

› User-friendly menu structure

› Designed for easy mounting

Page 85: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4053

MT_WP4053_DataSheet_R5_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Technical Data

CPU RISC 32 bits, 600 MHz (ARM® Cortex™-A8)Backup memory FRAM 1M bit (=128K Byte, 64word)Memory DDR2 256MB on boardStorage 1GB on board SLC typePower-On LED Yes

Ethernet (RJ45) 10/100-BaseTI/Os USB Host: USB 2.0 Host x 1

Display type WVGA TFT LCDDisplay size 7"Max. resolution 800 x 480Max. colors 64KLuminance (cd/m2) 500Viewing angle (H/V) 140/120Backlight life LED, 50.000 hrsContrast ratio 700:1

Lifespan 36 million touches at 8mm diameter finger point throughsilicone rubber bearing at least 250g 2 times per second.

Light Transmission above 80%Resolution LinearityType 5-wire, analog resistive

Required voltage 24VDC ±10%Typical 0.29A @ 24VDC (Power supply must be able to deliver minimum 0.4A)

Power consumption 7W (Typical)

Operating temperature -30 to +60°CStorage temperature -40 to +70°CRelative humidity 10 to 90% RH (non-condensing @ 40°C)

Weight (Net) 1 kgDimensions (WxHxD) 203.4 x 150 x 43.7 mmCut-out dimensions 192 x 138.5 mmEnclosure housing PC + ABSMounting PanelDegree of protection Front panel: IP66

Certifications CE, BSMI, CCC, UL, FCC Class AVibration Operating, random vibration 1 Grms (5 - 500 Hz)IEC IEC 60068-2-6:2007 Standard | rural electrification | Environmental

testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Communication Interface

LCD Display

External 24V

Module Power Consumption

Permissible Ambient Conditions

Applied Standards

Mechanical Information

System Hardware

Touchscreen

Page 86: Data Sheets - mita-teknik.com · WP4200 Platform control sstems MTWP4200-0 PlatformDataheet0 20 Mita-Teknik ll rights resered ecications sect to change WP4200 Variants WP4200 - 00

control systemsWP4053

MT_WP4053_DataSheet_R5_0

®

© 2018 Mita-Teknik. All rights reserved

Specifications subject to change

Mita-Teknik Ordering Information

Technical Data

Order Number Order Name978405301 WP4053 Touch Display

Accessories3389210 Ethernet Patch Cable RJ45, STP, Grey, 1.0 meter3389220 Ethernet Patch Cable RJ45, STP, Grey, 2.0 meter3389250 Ethernet Patch Cable RJ45, STP, Grey, 5.0 meter7980775 Adapter Plate WP3050/WP4059 to WP4053 Display

CPU RISC 32 bits, 600 MHz (ARM® Cortex™-A8)Backup memory FRAM 1M bit (=128K Byte, 64word)Memory DDR2 256MB on boardStorage 1GB on board SLC typePower-On LED Yes

Ethernet (RJ45) 10/100-BaseTI/Os USB Host: USB 2.0 Host x 1

Display type WVGA TFT LCDDisplay size 7"Max. resolution 800 x 480Max. colors 64KLuminance (cd/m2) 500Viewing angle (H/V) 140/120Backlight life LED, 50.000 hrsContrast ratio 700:1

Lifespan 36 million touches at 8mm diameter finger point throughsilicone rubber bearing at least 250g 2 times per second.

Light Transmission above 80%Resolution LinearityType 5-wire, analog resistive

Required voltage 24VDC ±10%Typical 0.29A @ 24VDC (Power supply must be able to deliver minimum 0.4A)

Power consumption 7W (Typical)

Operating temperature -30 to +60°CStorage temperature -40 to +70°CRelative humidity 10 to 90% RH (non-condensing @ 40°C)

Weight (Net) 1 kgDimensions (WxHxD) 203.4 x 150 x 43.7 mmCut-out dimensions 192 x 138.5 mmEnclosure housing PC + ABSMounting PanelDegree of protection Front panel: IP66

Certifications CE, BSMI, CCC, UL, FCC Class AVibration Operating, random vibration 1 Grms (5 - 500 Hz)IEC IEC 60068-2-6:2007 Standard | rural electrification | Environmental

testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)EMC EN 61000-6-2 (Immunity standard for industrial environments)

EN 61000-6-4 (Emission standard for industrial environments)

Communication Interface

LCD Display

External 24V

Module Power Consumption

Permissible Ambient Conditions

Applied Standards