datacenter training program dcpro in jakarta 2017

21
© 2017 PT. Niscom Data Solusi DCPRO comes INDONESIA again PT. Niscom Data Solusi October, 2016 - DataCenter Training Program - in Jakarta 2017

Upload: keisuke-manabe

Post on 14-Feb-2017

198 views

Category:

Engineering


5 download

TRANSCRIPT

Page 1: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi

DCPROcomes INDONESIA again

PT. Niscom Data SolusiOctober, 2016

- DataCenter Training Program -in Jakarta 2017

Page 2: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi2

ü  Worldwide best practice training program provided for DC folks by DataCenterDynamics in U.K.

ü  Acquire the latest international standards & tech skills of all DC components

Whatʼs DCPRO- Data Center Professional Development

ü  Expert instructors w/ over 10 yrs experience

ü  Interactive learning experience

ü  Blended learning solutions (classroom, online) & Specialist career progression tracks for advanced learning

ü  Finally To Indonesia in 2016!

Page 3: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi3

American Institute of Architects (AIA) / BCS / The Chartered Institute of IT / Chartered Institute of Building Services Engineers (CIBSE) / Institute of Electrical and Electronic Engineers (IEEE) / NCEES/RCEP / Engineers Australia / BICSI.

Accredited bodies

Recognized by the international accredited bodies

Page 4: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi4

Specialist in their own field with more than 10 years experiencesWe have different trainers for the different courses most of the time

as only the specialist will deliver the courses in their field

- Asia Pacific Trainers -

Expert Instructors

Page 5: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi

Interactive Learning Experience

5

Page 6: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi6

Career Progression Framework

Upcoming class in Jakarta

*New

Page 7: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi7

DC Practitioner(DCP) Certificate

ROUTES IN JAKARTA

YOUR BUSINESSCARD

CLASSROOM

Page 8: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi8

DC Specialist (DCS) Certificate

ROUTES IN JAKARTA

YOUR BUSINESSCARD

CLASSROOM

ONLINE

Page 9: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi9

Jakarta Class in 2017

Lv. CourseJan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

1

DCDA ● ● ● ● ●

DCT*New ●

2 EEBP ● ● ●

3 COP ● ●

6-8 8-10 10-12 6-8 1-3

8,9

9,10 13,14 6,7

15-17 11-13

Note: ●Fixed ●Scheduled **Minimum class atendee:8

FLEXIBLE SCHEDULE**Please let us know if you want it on other dates, we are flexible to arrange it for you in INDONESIA

Page 10: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi10

APPENDIX

Page 11: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi11

Course Level Job scope Location Duration StandardPrice

DCDA-  Data Center Design Awareness Level 1

•  Data Center Operator•  OEM Supplier•  Sales Engineer•  Project Manager•  Facilities Manager

Jakarta 3days

$1,950USD

DCT-  Data Center Technician Level 1

•  Datacenter Service Manager•  Datacenter Technician•  Telecommunications Engineers•  Data Center Facilities Technician•  Customer Service Manager•  Field Sales Engineer

Jakarta 2days

$1,200USD

EEBP- Energy Efficiency Best Practice Level 2

•  IT Manager•  M&E Consultant•  HVAC Engineer•  Property Developer•  Facility Manager•  Project Manager•  Data Center Owner/ Operator•  Building Contractor

Jakarta 2days

$1,350USD

COP- Critical Operations Professional Level 3

•  M&E Operational Management•  Data Center Manager•  Business Unit/ Client Manager•  Construction Project Manager

Jakarta 3days

$2,850USD

Upcoming Jakarta Class

Page 12: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi

Learn the key elements that influence the design of the modern data center. From site selection to cabling infrastructure, this course focuses on the key skills required to understand the design concepts and interdependencies associated with each discipline.

Course Content :1.  Data Center Evolution 2.  Facility Classification3.  Site Selection 4.  Architectural Design5.  Raised Floor6.  Room Layout7.  Infrastructure Connectivity8.  IT Architecture and Network Design9.  Cooling Systems and Environmental Control10.  Fire Systems

Professional Development Hrs 21

Exam Half or 1 hour, open book

Pre-requisites None

Suggested Progression Energy Efficiency

12

Standard Price: $1,950 USD (tax-excluded)

DCDADataCenter Design Awareness

12

Page 13: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi13

Data Center Evolution• Technology advances• Todayʼs challenges• Relevant industry bodies• Current standards and regulations• Key definitions and metrics

Facility Classification• Market trends, regulations and design impact• Balancing IT capacity and efficiency• Design and project process• Critical classifications – Uptime Institute, TIA, BICSCI• Availability and the impact of downtime• Business needs assessment – TCO and ROI• Data center options – enterprise, colo, MSP, wholesale

Site Selection• Site adjacency standards and recommend• Availability of water, power, telco, gas and air• Geographical influences and recommendations• Future Thinking – PUE, environment, modular

Architectural Design• External shell – materials, solar gain, engineering• Space considerations – computer room layout, support areas and external space• Structural specifications – floor, ceiling and wall• Traditional build vs modular options

IT Architecture and Network Design• Servers – pizza box vs chassis vs blade and next gen.• Storage – DAS vs NAS vs SAN, RAID, clustering, disk drives, table libraries, solid state and storage management• Communications – aggregation, edge and core switches, routers, resilience• Virtualisation, FcoE• Impact of speed on design – 1/10/40/100/400G• Designing today to meet tomorrowʼs challenges

Cooling Systems and Env Control• Cooling fundamentals and definitions• Cooling options – CRAC, CRAH, DX, refrigerants, aid and water system advantages and disadvantages• ASHRAE limits – recommended A1 to A4• Design considerations, legacy, hot/cold aisle, containment• System efficiency – bypass, recirculation, static pressure, thermal capacity, free cooling, air/water economization, rotary and static heat exchangers, CHP, zero refrigeration

Fire Systems• Fire Regulations & rating systems• Fire prevention – compartment & barrier design• Fire detection & warning – smoke, heat, flame detection systems, fire panels• Fire suppression systems – wet & dry pipe, water mist, inert&synthetic gas, CO2, hypoxic• System design considerations

Raised Floor• Floor loadings – concentrated, uniform, rolling• Design and construction considerations• Air grill tiles – open space vs flow rates• Ramp design – location, heights and inclines• Cutting tiles – best practices, sealing gaps• Managing zinc whiskers and other contaminants

Room Layout• Equipment considerations• IT cabinet types• Hot aisle/cold aisle configuration• Non-standard equipment considerations

Infrastructure Connectivity• Copper shielded and unshielded cables, connectors, categories, bandwidth, distances, fire rating• Fiber single and multimode cable, simplex and array connectors, bandwidth, distance, loss, operational costs• Cable location and containment best practice, space allocation, overhead vs underfloor• Connectivity design options –EoR, ToR, no. of connections, resilience – N, N+1, 2N• Future developments

DCDA - Course Content -

13

Page 14: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi14

Your Name

Certificate

Page 15: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi

Our Energy Efficiency course explores strategies for the effective use of energy within the data center; incorporating standards imposed by the EU Code of Conduct, The Green Grid, ASHRAE, BCS - The Chartered Institute for IT, and IEEE.

Course Content :1.  The Global Energy Efficiency Landscape2.  Key Drivers3.  Auditing and Assessment4.  Monitoring and Measuring5.  IT Hardware

Professional Development Hrs 14

Exam 1 hour, open book

Pre-requisitesNone (although completion of our foundation level ʻData Center Design Awarenessʼ course isrecommended) on

Suggested ProgressionData Center Cooling Professional + Data CenterPower Professional OR Energy & Cost Management + Critical Operations Professional

15Standard Price: $1,350 USD (tax-excluded)

6.  Cooling Architectures7.  Power Architectures8.  Rightsizing and Capacity Management9.  Commissioning and Maintenance

EEBPEnergy Efficiency Best Practice

15

Page 16: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi16

Global Energy Efficiency Landscape• Global energy outlook• Global data services outlook• Global & local energy efficiency landscape• Relevant industry bodies

Key Drivers• Energy cost growth• Energy availability security concerns• End user behaviour vs infrastructure change• Differentiating green strategies from sustainability & energy efficiency• The data center energy lifecycle• Energy efficiency opportunities – identifying the losses in the power chain from generation to the chip• Management efficiency – efficiency at organizational level, IT vs facilities paradigm, TCO vs ROI, procurement for efficiency• Building ratings – World Green Building Council, NABERS, LEED, BREEAM, Singapore, China• Energy efficient product rating – 80 plus, Green Star, E3, TCO• Data Center rating schemes – NABERS, LEED, EUCoC, CEEDA• Examples of worst practices across the data center• Standards & best practices

Auditing & Assessment• Data center maturity model• Assessment of different data center types• Assessment of different industry types

Cooling Architectures• ASHRAE thermal guidelines – implementing A1 to A4• Air flow management• Temperature & humidity settings• Containment strategies• Free cooling analysis• VFDʼs• Cutting edge cooling• Location & efficiency

Power Architectures• Electrical efficiency best practice• Rotary & static UPS efficiency• Cogeneration

Rightsizing & Capacity Management• Design vs implementation strategies for efficiency• Load variation design options• Impact of redundant components on efficiency• Zone design• Modular design• Retrofit vs new construction

Commissioning & Maintenance• Building a project delivery team• Stakeholder involvement• Maintaining for efficiency• Future efficiency opportunity

• NABERS audit & assessment scheme• Impact of availability & resilience on efficiency• State of the art efficiency strategies• Application of organizational efficiency metrics• Customized metrics• Metrics for water, carbon and business productivity

Monitoring and Measuring• Measuring implementation levels• Manual and automated measurement• Incoming utility measurement• Standalone vs shared & mixed use buildings• Measuring electrical power consumption• Measuring IT equipment consumption• DCIM and new technologies

IT Hardware• Servers – innovative solutions for the big consumers• Processor performance vs efficiency• Mooreʼs Law and Koomeyʼs Law• Power usage analysis & opportunities• Custom design solutions• Power management features and issues• Unused servers• Getting the most out of virtualization, consolidation and load sharing• Lifecycle analysis• Storage energy efficiency• Online vs offline, deduplication, email quotas• Impact of infrastructure cabling on efficiency

EEBP - Course Content -

16

Page 17: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi

Learn the successful operation of a data center by facilities, moves and changes and cabling teams.This Specialist level course covers the re-evaluation of business criticality and Tier levels to critical operations procedures, this advanced level course encourages students to discuss their real-world experiences within the classroom.

Course Content :1.  Business requirement 2.  Data center finance 3.  Downtime, Human Factors and Staffing4.  Incidents, Failures, Scenarios and Managing Risk5.  Mechanical and Electrical Infrastructure Operations6.  Cooling Systems, Energy Management and Savings7.  IT Equipment, Telecommunications and Cabling and

Change Management8.  Ancillary Services and Building and Facilities

Management9.  Maintenance Contracts10.  Records and Contracts

Hours 21

Exam 1 hour, open book

Pre-requisitesRecommended 1-2 yrs verifiableexperience in a data center/computer room environment

Suggested Progression Energy & Cost Management + online courses

17Standard Price: $2,850 USD (tax-excluded)

COPCritical Operations professional

17

Who Should Attend :n  M&E Operational Managementn  Data Center Managern  Business Unit/ Client Managern  Construction Project Manager

Page 18: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi18

Business Requirements• Types of data center• Business needs assessment• Demand forecasting• Tier classifications• Availability requirements

Data Center Finance• Budget classifications• Total cost of ownership• Data center budgets• Accruals and estimated liabilities• Financial statements and reporting

Downtime, Human Factors and Staffing• Downtime impact and causes• Human factors• Organizational structures and staffing• Summaries

Incidents, Failures, Scenarios and Managing Risk• Risk management and assessment methods• Methodologies• Risk assessment checklist

Mechanical and Electrical Infrastructure Operations• Critical operations• Maintenance• Safe systems of work• Interdependencies• Critical plant switching operations

Cooling Systems, Energy Management and Savings• Introduction to cooling operations• Impact on cooling design and operations• New operating parameters• New efficiency metrics• Why energy savings?• EU code of conduct• Energy management and savings

IT Equipment, Telecommunications and Cabling and Change Management• Mechanical and electrical (M&E) operations• IT infrastructure moves, adds and changes (MAC)• Organizational change• Supplier change• Service provider change

Ancillary Services and Building and Facilities Management• BMS definitions and protocols• Integrated systems: BMS/BAS/DCIM• Reporting systems and requirements

Maintenance Contracts• Compliance and applicable standards• Ancillary services and facility maintenance

Records and Contracts• Maintenance contracts• Different types of contract• Scope of services• Statutory registers and records

COP - Course Content -

18

Page 19: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi19

n Global companiesEquinix, Digital Realty, Global Switch, Warren & Brown, M+W, Amazon Web Services, ABB, Eaton, Anixter, Fujitsu, Hitachi, TATA Communications, Google, Facebook, Cummins, Fujitsu, Barclays, Telstra, Schneider Electric, Racks Central, Kingsland, IO, Hoppecke, 1-Net, AMCOM, etc.

n Local companiesBanks, Securities/FinancesDC Operators, DC ConsultantsDC Manufacturers/Constructors etc.

Participants

Page 20: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi20

MEDIA EVENT EDUCATION

About DataCenterDynamics

Page 21: DataCenter Training Program DCPRO in Jakarta 2017

© 2017 PT. Niscom Data Solusi21

Apply & [email protected]

+81 80 3397 5939 *Whatsapp available

VISIT OUR FACEBOOK & CATCH THE LATEST!facebook.com/niscomdatasolusi

TERIMA KASIH! THANK YOU!

PT. Niscom Data Solusiwww.niscom.co.id