datacenter training program dcpro in jakarta 2017
TRANSCRIPT
© 2017 PT. Niscom Data Solusi
DCPROcomes INDONESIA again
PT. Niscom Data SolusiOctober, 2016
- DataCenter Training Program -in Jakarta 2017
© 2017 PT. Niscom Data Solusi2
ü Worldwide best practice training program provided for DC folks by DataCenterDynamics in U.K.
ü Acquire the latest international standards & tech skills of all DC components
Whatʼs DCPRO- Data Center Professional Development
ü Expert instructors w/ over 10 yrs experience
ü Interactive learning experience
ü Blended learning solutions (classroom, online) & Specialist career progression tracks for advanced learning
ü Finally To Indonesia in 2016!
© 2017 PT. Niscom Data Solusi3
American Institute of Architects (AIA) / BCS / The Chartered Institute of IT / Chartered Institute of Building Services Engineers (CIBSE) / Institute of Electrical and Electronic Engineers (IEEE) / NCEES/RCEP / Engineers Australia / BICSI.
Accredited bodies
Recognized by the international accredited bodies
© 2017 PT. Niscom Data Solusi4
Specialist in their own field with more than 10 years experiencesWe have different trainers for the different courses most of the time
as only the specialist will deliver the courses in their field
- Asia Pacific Trainers -
Expert Instructors
© 2017 PT. Niscom Data Solusi
Interactive Learning Experience
5
© 2017 PT. Niscom Data Solusi6
Career Progression Framework
Upcoming class in Jakarta
*New
© 2017 PT. Niscom Data Solusi7
DC Practitioner(DCP) Certificate
ROUTES IN JAKARTA
YOUR BUSINESSCARD
CLASSROOM
© 2017 PT. Niscom Data Solusi8
DC Specialist (DCS) Certificate
ROUTES IN JAKARTA
YOUR BUSINESSCARD
CLASSROOM
ONLINE
© 2017 PT. Niscom Data Solusi9
Jakarta Class in 2017
Lv. CourseJan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
1
DCDA ● ● ● ● ●
DCT*New ●
2 EEBP ● ● ●
3 COP ● ●
6-8 8-10 10-12 6-8 1-3
8,9
9,10 13,14 6,7
15-17 11-13
Note: ●Fixed ●Scheduled **Minimum class atendee:8
FLEXIBLE SCHEDULE**Please let us know if you want it on other dates, we are flexible to arrange it for you in INDONESIA
© 2017 PT. Niscom Data Solusi10
APPENDIX
© 2017 PT. Niscom Data Solusi11
Course Level Job scope Location Duration StandardPrice
DCDA- Data Center Design Awareness Level 1
• Data Center Operator• OEM Supplier• Sales Engineer• Project Manager• Facilities Manager
Jakarta 3days
$1,950USD
DCT- Data Center Technician Level 1
• Datacenter Service Manager• Datacenter Technician• Telecommunications Engineers• Data Center Facilities Technician• Customer Service Manager• Field Sales Engineer
Jakarta 2days
$1,200USD
EEBP- Energy Efficiency Best Practice Level 2
• IT Manager• M&E Consultant• HVAC Engineer• Property Developer• Facility Manager• Project Manager• Data Center Owner/ Operator• Building Contractor
Jakarta 2days
$1,350USD
COP- Critical Operations Professional Level 3
• M&E Operational Management• Data Center Manager• Business Unit/ Client Manager• Construction Project Manager
Jakarta 3days
$2,850USD
Upcoming Jakarta Class
© 2017 PT. Niscom Data Solusi
Learn the key elements that influence the design of the modern data center. From site selection to cabling infrastructure, this course focuses on the key skills required to understand the design concepts and interdependencies associated with each discipline.
Course Content :1. Data Center Evolution 2. Facility Classification3. Site Selection 4. Architectural Design5. Raised Floor6. Room Layout7. Infrastructure Connectivity8. IT Architecture and Network Design9. Cooling Systems and Environmental Control10. Fire Systems
Professional Development Hrs 21
Exam Half or 1 hour, open book
Pre-requisites None
Suggested Progression Energy Efficiency
12
Standard Price: $1,950 USD (tax-excluded)
DCDADataCenter Design Awareness
12
© 2017 PT. Niscom Data Solusi13
Data Center Evolution• Technology advances• Todayʼs challenges• Relevant industry bodies• Current standards and regulations• Key definitions and metrics
Facility Classification• Market trends, regulations and design impact• Balancing IT capacity and efficiency• Design and project process• Critical classifications – Uptime Institute, TIA, BICSCI• Availability and the impact of downtime• Business needs assessment – TCO and ROI• Data center options – enterprise, colo, MSP, wholesale
Site Selection• Site adjacency standards and recommend• Availability of water, power, telco, gas and air• Geographical influences and recommendations• Future Thinking – PUE, environment, modular
Architectural Design• External shell – materials, solar gain, engineering• Space considerations – computer room layout, support areas and external space• Structural specifications – floor, ceiling and wall• Traditional build vs modular options
IT Architecture and Network Design• Servers – pizza box vs chassis vs blade and next gen.• Storage – DAS vs NAS vs SAN, RAID, clustering, disk drives, table libraries, solid state and storage management• Communications – aggregation, edge and core switches, routers, resilience• Virtualisation, FcoE• Impact of speed on design – 1/10/40/100/400G• Designing today to meet tomorrowʼs challenges
Cooling Systems and Env Control• Cooling fundamentals and definitions• Cooling options – CRAC, CRAH, DX, refrigerants, aid and water system advantages and disadvantages• ASHRAE limits – recommended A1 to A4• Design considerations, legacy, hot/cold aisle, containment• System efficiency – bypass, recirculation, static pressure, thermal capacity, free cooling, air/water economization, rotary and static heat exchangers, CHP, zero refrigeration
Fire Systems• Fire Regulations & rating systems• Fire prevention – compartment & barrier design• Fire detection & warning – smoke, heat, flame detection systems, fire panels• Fire suppression systems – wet & dry pipe, water mist, inert&synthetic gas, CO2, hypoxic• System design considerations
Raised Floor• Floor loadings – concentrated, uniform, rolling• Design and construction considerations• Air grill tiles – open space vs flow rates• Ramp design – location, heights and inclines• Cutting tiles – best practices, sealing gaps• Managing zinc whiskers and other contaminants
Room Layout• Equipment considerations• IT cabinet types• Hot aisle/cold aisle configuration• Non-standard equipment considerations
Infrastructure Connectivity• Copper shielded and unshielded cables, connectors, categories, bandwidth, distances, fire rating• Fiber single and multimode cable, simplex and array connectors, bandwidth, distance, loss, operational costs• Cable location and containment best practice, space allocation, overhead vs underfloor• Connectivity design options –EoR, ToR, no. of connections, resilience – N, N+1, 2N• Future developments
DCDA - Course Content -
13
© 2017 PT. Niscom Data Solusi14
Your Name
Certificate
© 2017 PT. Niscom Data Solusi
Our Energy Efficiency course explores strategies for the effective use of energy within the data center; incorporating standards imposed by the EU Code of Conduct, The Green Grid, ASHRAE, BCS - The Chartered Institute for IT, and IEEE.
Course Content :1. The Global Energy Efficiency Landscape2. Key Drivers3. Auditing and Assessment4. Monitoring and Measuring5. IT Hardware
Professional Development Hrs 14
Exam 1 hour, open book
Pre-requisitesNone (although completion of our foundation level ʻData Center Design Awarenessʼ course isrecommended) on
Suggested ProgressionData Center Cooling Professional + Data CenterPower Professional OR Energy & Cost Management + Critical Operations Professional
15Standard Price: $1,350 USD (tax-excluded)
6. Cooling Architectures7. Power Architectures8. Rightsizing and Capacity Management9. Commissioning and Maintenance
EEBPEnergy Efficiency Best Practice
15
© 2017 PT. Niscom Data Solusi16
Global Energy Efficiency Landscape• Global energy outlook• Global data services outlook• Global & local energy efficiency landscape• Relevant industry bodies
Key Drivers• Energy cost growth• Energy availability security concerns• End user behaviour vs infrastructure change• Differentiating green strategies from sustainability & energy efficiency• The data center energy lifecycle• Energy efficiency opportunities – identifying the losses in the power chain from generation to the chip• Management efficiency – efficiency at organizational level, IT vs facilities paradigm, TCO vs ROI, procurement for efficiency• Building ratings – World Green Building Council, NABERS, LEED, BREEAM, Singapore, China• Energy efficient product rating – 80 plus, Green Star, E3, TCO• Data Center rating schemes – NABERS, LEED, EUCoC, CEEDA• Examples of worst practices across the data center• Standards & best practices
Auditing & Assessment• Data center maturity model• Assessment of different data center types• Assessment of different industry types
Cooling Architectures• ASHRAE thermal guidelines – implementing A1 to A4• Air flow management• Temperature & humidity settings• Containment strategies• Free cooling analysis• VFDʼs• Cutting edge cooling• Location & efficiency
Power Architectures• Electrical efficiency best practice• Rotary & static UPS efficiency• Cogeneration
Rightsizing & Capacity Management• Design vs implementation strategies for efficiency• Load variation design options• Impact of redundant components on efficiency• Zone design• Modular design• Retrofit vs new construction
Commissioning & Maintenance• Building a project delivery team• Stakeholder involvement• Maintaining for efficiency• Future efficiency opportunity
• NABERS audit & assessment scheme• Impact of availability & resilience on efficiency• State of the art efficiency strategies• Application of organizational efficiency metrics• Customized metrics• Metrics for water, carbon and business productivity
Monitoring and Measuring• Measuring implementation levels• Manual and automated measurement• Incoming utility measurement• Standalone vs shared & mixed use buildings• Measuring electrical power consumption• Measuring IT equipment consumption• DCIM and new technologies
IT Hardware• Servers – innovative solutions for the big consumers• Processor performance vs efficiency• Mooreʼs Law and Koomeyʼs Law• Power usage analysis & opportunities• Custom design solutions• Power management features and issues• Unused servers• Getting the most out of virtualization, consolidation and load sharing• Lifecycle analysis• Storage energy efficiency• Online vs offline, deduplication, email quotas• Impact of infrastructure cabling on efficiency
EEBP - Course Content -
16
© 2017 PT. Niscom Data Solusi
Learn the successful operation of a data center by facilities, moves and changes and cabling teams.This Specialist level course covers the re-evaluation of business criticality and Tier levels to critical operations procedures, this advanced level course encourages students to discuss their real-world experiences within the classroom.
Course Content :1. Business requirement 2. Data center finance 3. Downtime, Human Factors and Staffing4. Incidents, Failures, Scenarios and Managing Risk5. Mechanical and Electrical Infrastructure Operations6. Cooling Systems, Energy Management and Savings7. IT Equipment, Telecommunications and Cabling and
Change Management8. Ancillary Services and Building and Facilities
Management9. Maintenance Contracts10. Records and Contracts
Hours 21
Exam 1 hour, open book
Pre-requisitesRecommended 1-2 yrs verifiableexperience in a data center/computer room environment
Suggested Progression Energy & Cost Management + online courses
17Standard Price: $2,850 USD (tax-excluded)
COPCritical Operations professional
17
Who Should Attend :n M&E Operational Managementn Data Center Managern Business Unit/ Client Managern Construction Project Manager
© 2017 PT. Niscom Data Solusi18
Business Requirements• Types of data center• Business needs assessment• Demand forecasting• Tier classifications• Availability requirements
Data Center Finance• Budget classifications• Total cost of ownership• Data center budgets• Accruals and estimated liabilities• Financial statements and reporting
Downtime, Human Factors and Staffing• Downtime impact and causes• Human factors• Organizational structures and staffing• Summaries
Incidents, Failures, Scenarios and Managing Risk• Risk management and assessment methods• Methodologies• Risk assessment checklist
Mechanical and Electrical Infrastructure Operations• Critical operations• Maintenance• Safe systems of work• Interdependencies• Critical plant switching operations
Cooling Systems, Energy Management and Savings• Introduction to cooling operations• Impact on cooling design and operations• New operating parameters• New efficiency metrics• Why energy savings?• EU code of conduct• Energy management and savings
IT Equipment, Telecommunications and Cabling and Change Management• Mechanical and electrical (M&E) operations• IT infrastructure moves, adds and changes (MAC)• Organizational change• Supplier change• Service provider change
Ancillary Services and Building and Facilities Management• BMS definitions and protocols• Integrated systems: BMS/BAS/DCIM• Reporting systems and requirements
Maintenance Contracts• Compliance and applicable standards• Ancillary services and facility maintenance
Records and Contracts• Maintenance contracts• Different types of contract• Scope of services• Statutory registers and records
COP - Course Content -
18
© 2017 PT. Niscom Data Solusi19
n Global companiesEquinix, Digital Realty, Global Switch, Warren & Brown, M+W, Amazon Web Services, ABB, Eaton, Anixter, Fujitsu, Hitachi, TATA Communications, Google, Facebook, Cummins, Fujitsu, Barclays, Telstra, Schneider Electric, Racks Central, Kingsland, IO, Hoppecke, 1-Net, AMCOM, etc.
n Local companiesBanks, Securities/FinancesDC Operators, DC ConsultantsDC Manufacturers/Constructors etc.
Participants
© 2017 PT. Niscom Data Solusi20
MEDIA EVENT EDUCATION
About DataCenterDynamics
© 2017 PT. Niscom Data Solusi21
Apply & [email protected]
+81 80 3397 5939 *Whatsapp available
VISIT OUR FACEBOOK & CATCH THE LATEST!facebook.com/niscomdatasolusi
TERIMA KASIH! THANK YOU!
PT. Niscom Data Solusiwww.niscom.co.id