RS, Professionally Approved Products, gives you professional quality parts across all products categories. Our range has been testified by engineers as giving comparable quality to that of the leading brands without paying a premium price. Cells Per Unit Weight Terminal Recommended Maximum Charging Current Limit Operating Temp.Range Nominal Operating Temp. Range Self Discharge Max. Discharge Current Internal Resistance 6 The batteries can be stored for more than 6 months at 25 . Self-discharge ratio less than 3% per month at 25 . Please charge batteries before using. 0 C 0 C Float charging Voltage Equalization and Cycle Service 13.5to 13.8VDC/unit Average at 25 0 C 0 14.4 C to15.0 VDC/unit Average at 25 Capacity Voltage Per Unit 12 Approx 23m Ù 105A (5 sec) 2.1A 0 0 25 3 C (77 5 F ) Approx 2.2 kg 0 0 Discharge : -15 50 C (5 122 F) 0 0 Charge : 0 40 C (32 104 F) 0 0 Storage : -15 40 C (5 104 F) 7.0Ah@20hr-rate to 1.80V per cell @25 0 C Container Material A.B.S. (UL94-V0 ) , Flammability resistance of UL94-HB can be available upon request. Specification Sealed Lead-Acid Battery General Purpose 150-1556(12V .0Ah) All purpose Uninterruptable Power Supply (UPS) Electric Power System (EPS) Emergency backup power supply Emergency light Railway signal Aircraft signal Alarm and security system Electronic apparatus and equipment Communication power supply DC power supply Auto control system Applications T1 7 Dimensions Unit: mm Dimension: 151(L) 65(W) 99(H) Terminal T1 Constant Current Discharge Characteristics : A 0 (25 C ) Constant Power Discharge Characteristics : W 0 (25 C ) 3.2 6.35 0.83 4.75 93.5±1 99±1 43 65±1 151±2 1.85V/cell 1.80V/cell 1.75V/cell 1.70V/cell 1.65V/cell 1.60V/cell 5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 20min F.V/Time 16.0 11.7 9.97 8.46 6.17 4.52 3.60 2.14 1.60 1.30 1.10 0.95 0.756 0.626 0.343 19.2 13.7 11.3 9.20 6.65 4.80 3.83 2.24 1.66 1.35 1.14 0.99 0.783 0.653 0.350 21.5 14.9 12.0 9.70 6.92 4.99 3.98 2.31 1.71 1.38 1.16 1.01 0.795 0.663 0.357 23.4 15.9 12.8 10.2 7.18 5.12 4.05 2.36 1.75 1.41 1.19 1.03 0.812 0.672 0.361 25.5 16.8 13.4 10.6 7.43 5.28 4.17 2.40 1.77 1.43 1.21 1.04 0.823 0.680 0.365 26.8 17.6 13.8 10.9 7.64 5.42 4.26 2.46 1.81 1.46 1.23 1.06 0.837 0.690 0.371 5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 20min F.V/Time 1.85V/cell 1.80V/cell 1.75V/cell 1.70V/cell 1.65V/cell 1.60V/cell 30.3 22.3 19.2 16.4 12.0 8.86 7.09 4.23 3.17 2.59 2.20 1.91 1.52 1.26 0.694 35.9 25.8 21.5 17.7 12.9 9.37 7.52 4.42 3.30 2.69 2.27 1.97 1.57 1.31 0.704 39.8 28.0 22.8 18.6 13.4 9.72 7.79 4.55 3.37 2.74 2.31 2.00 1.59 1.33 0.716 42.8 29.5 24.0 19.3 13.8 9.89 7.88 4.61 3.42 2.78 2.34 2.03 1.61 1.33 0.718 45.7 30.7 24.8 19.8 14.1 10.1 8.02 4.65 3.45 2.80 2.36 2.05 1.62 1.34 0.720 47.0 31.5 25.1 20.1 14.3 10.3 8.13 4.73 3.50 2.83 2.39 2.07 1.63 1.35 0.728 Datasheet

Upload: others

Post on 02-Aug-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Datasheet - RS ComponentsDatasheet 0.093C 0.05C 0.207C 0.4C 1C 0.628C 3C 2C 1 2 4 610 20 40 60 2 4 8 10 Min H 8 20 13.0 12.0 11.0 10.0 9.0 8.0 Temperature:250C(77F)0 T er m inal V

RS, Professionally Approved Products, gives you professional quality parts across all products categories. Our range hasbeen testified by engineers as giving comparable quality to that of the leading brands without paying a premium price.

Cells Per Unit

Weight

Terminal

Recommended Maximum ChargingCurrent Limit

Operating Temp.Range

Nominal Operating Temp. Range

Self Discharge

Max. Discharge Current

Internal Resistance

6

The batteries can be stored for more than 6 monthsat 25 . Self-discharge ratio less than 3% per monthat 25 . Please charge batteries before using.

0C0C

Float charging Voltage

Equalization and Cycle Service

13.5to 13.8VDC/unit Average at 250C

014.4 Cto15.0 VDC/unit Average at 25

Capacity

Voltage Per Unit 12

Approx 23m Ù

105A (5 sec)

2.1A

0 025 3 C (77 5 F )

Approx 2.2 kg

0 0Discharge : -15 50 C (5 122 F)0 0Charge : 0 40 C (32 104 F)0 0Storage : -15 40 C (5 104 F)

7.0Ah@20hr-rate to 1.80V per cell @250C

Container MaterialA.B.S. (UL94-V0 ) , Flammability resistance of UL94-HBcan be available upon request.

Specification

Sealed Lead-Acid BatteryGeneral Purpose

150-1556(12V7.0Ah)

All purpose

Uninterruptable Power Supply (UPS)

Electric Power System (EPS)

Emergency backup power supply

Emergency light

Railway signal

Aircraft signal

Alarm and security system

Electronic apparatus and equipment

Communication power supply

DC power supply

Auto control system

Applications

T1

7

Dimensions

Unit: mm Dimension: 151(L) 65(W) 99(H)Terminal T1

Constant Current Discharge Characteristics : A 0 (25 C )

Constant Power Discharge Characteristics : W 0 (25 C )

3.2

6.35

0.8

34

.75

93.5±

1

99±

1

43

65±

1

151±2

1.85V/cell

1.80V/cell

1.75V/cell

1.70V/cell

1.65V/cell

1.60V/cell

5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h20minF.V/Time

16.0 11.7 9.97 8.46 6.17 4.52 3.60 2.14 1.60 1.30 1.10 0.95 0.756 0.626 0.343

19.2 13.7 11.3 9.20 6.65 4.80 3.83 2.24 1.66 1.35 1.14 0.99 0.783 0.653 0.350

21.5 14.9 12.0 9.70 6.92 4.99 3.98 2.31 1.71 1.38 1.16 1.01 0.795 0.663 0.357

23.4 15.9 12.8 10.2 7.18 5.12 4.05 2.36 1.75 1.41 1.19 1.03 0.812 0.672 0.361

25.5 16.8 13.4 10.6 7.43 5.28 4.17 2.40 1.77 1.43 1.21 1.04 0.823 0.680 0.365

26.8 17.6 13.8 10.9 7.64 5.42 4.26 2.46 1.81 1.46 1.23 1.06 0.837 0.690 0.371

5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h20minF.V/Time

1.85V/cell

1.80V/cell

1.75V/cell

1.70V/cell

1.65V/cell

1.60V/cell

30.3 22.3 19.2 16.4 12.0 8.86 7.09 4.23 3.17 2.59 2.20 1.91 1.52 1.26 0.694

35.9 25.8 21.5 17.7 12.9 9.37 7.52 4.42 3.30 2.69 2.27 1.97 1.57 1.31 0.704

39.8 28.0 22.8 18.6 13.4 9.72 7.79 4.55 3.37 2.74 2.31 2.00 1.59 1.33 0.716

42.8 29.5 24.0 19.3 13.8 9.89 7.88 4.61 3.42 2.78 2.34 2.03 1.61 1.33 0.718

45.7 30.7 24.8 19.8 14.1 10.1 8.02 4.65 3.45 2.80 2.36 2.05 1.62 1.34 0.720

47.0 31.5 25.1 20.1 14.3 10.3 8.13 4.73 3.50 2.83 2.39 2.07 1.63 1.35 0.728

Datasheet

Page 2: Datasheet - RS ComponentsDatasheet 0.093C 0.05C 0.207C 0.4C 1C 0.628C 3C 2C 1 2 4 610 20 40 60 2 4 8 10 Min H 8 20 13.0 12.0 11.0 10.0 9.0 8.0 Temperature:250C(77F)0 T er m inal V

0.05C0.093C0.207C

0.4C

0.628C1C

2C3C

101 2 4 6 20 40 60 2 4 6 8 10

HMin

8 20

13.0

12.0

11.0

10.0

9.0

8.0

0 0Temperature:25 C(77F)

Term

inal

Vol

tage

(V)

Discharge Time

Storage Time(Months)

Rem

aini

ngC

apac

ity(%

)

8 10 120

4 6

60

80

100

2

20

40

025 C

030 C040 C

010 C A

B

C

Discharge Characteristics

Self Discharge CharacteristicsEffect of Temperature on Long Term Float Life

Float Charging Characteristics

0 8 16 2012 24 28 32 36 40

12.0

13.0

14.0

15.0

(XCA)%

ChargeVolume

Charging Current

After 100% Discharge

Charge Voltage

(Constant 2.25v/cell)

Charging Current

11.0

4

0.10

0.15

0.20

0.25

0.05

00

10

20

30

50

40

60

70

80

90

100

120

110

Charging Voltage

(V)

Charging Time(hours)

00.10CA-2.25V/cell temperature25 C

After 50% Discharge

Charged Volume

Battery Type

AGMBattery

6V&12V

-20 -10 0 5 10 20 25 30 40 45

46% 66% 76% 83% 90% 98% 100% 103% 107% 109%

Discharge Current VS. Discharge Voltage

Final DischargeVoltage V/cell

DischargeCurrent (A)

1.80V 1.75V 1.60V

A 0.2C 0.2C A 1.0C A 1.0C

Charging Method:

Maintenance & Cautions

0.5

Battery temperature

1

2

3

456

8

10

Charging voltage :

2.25V/cell

2068

0C3086

40104

50122 OF

Life

expe

ctan

cy(y

ear)

Charge the batteries at least once every six months,if they are stored at 25 .0C

Float Service:

Equalisation charging is recommended once every 3 to 6 months using.

Discharge 100% rated capacity.

Charge 2.35v/cell constant voltage, maximum 0.3CA 24hrs.

Cyclic Service:

Temperature compensation for varying temperatures:

-Charge voltage -3mV/Cell/degC from 25degC norm.

Equalisation charge:

It is recommended to check battery/Float voltage each month.

The service life of your battery will be affected by:

-The number of discharge cycles, depth of discharge, ambient

temperature and charging voltage.

Constant Voltage

Constant Current

-0.2Cx2h+2.4~2.45V/Cellx24h,Max. Current 0.3CA

0.1C until the voltage reaching 14.4V,then 0.1Cx4h

TemperatureAvailable Capacity Sub ject to

No supplementary charge required(Carry out supplementary charge before use if 100% capacity is required.)

Supplementary charge required before use.Optional charging way as below:1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell.2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.3.Charged for 8~10hours at limted current 0.05CA .

Avoid this storage period unless regular Top charge.

B

C

A

Supplementary charge may often fail to recover the full capacity

RS, Professionally Approved Products, gives you professional quality parts across all products categories. Our range hasbeen testified by engineers as giving comparable quality to that of the leading brands without paying a premium price.