descriptionThe Interpoint™ SMFL Series™ 28-volt DC/DC converters
are rated p to 65 watts otpt power over a -55° to +125°C
temperatre rane with a 28 VDC nominal inpt. On dal otptmodels p to 70% of the rated otpt power can be drawn from
either the positive or neative otpts. Crrent sharin allowsthe nits to be paralleled for total power of p to 185 watts. The
welded, hermetically sealed packae is only 3.0 1.5 0.40
inches, ivin the series an overall power density of p to 43
watts per cbic inch.
Screening
SMFL converters, also available on SMD drawins, offer the
followin screenin options: Space Prototype (O), Class H, or
Class K. Radiation tolerant to Radiation Hardness Assrance(RHA) levels of “-” (O), “P,” or “R,” per MIL-PRF-38534. Interpoint
model nmbers se an “O” in the RHA desinator position toindicate the “-” (dash) Radiation Hardness Assrance level of
MIL-PRF-38534, which is defined as “no RHA”. See ScreeninTables 1 and 2
DeSign FeatureS
SMFL Series converters are switchin relators that se aqasi-sqare wave, sinle ended forward converter desin with a
constant switchin freqency of 600 kHz typical.
Isolation between inpt and otpt circits is provided with a
transformer in the forward path and a wide bandwidth maneticcoplin in the feedback control loop. The SMFL ses a niqe
dal loop feedback techniqe that controls otpt crrent withan inner feedback loop and an otpt voltae with a cascaded
voltae mode feedback loop. The additional secondary crrent
mode feedback loop improves transient response in a manner
similar to primary crrent mode control and allows for ease ofparallelin, bt withot the cost and compleity.
The constant freqency, plse-width modlated converters se
a qasi-sqare wave sinle-ended forward desin. Tiht load
relation is achieved throh a wide-bandwidth manetic feed-back circit. The otpt voltae on sinle SMFL models can
be trimmed to a specific otpt voltae by addin an eternalresistor (see Fire 1 for resistor vales).
inhibit
The SMFL Series converters have two inhibit terminals (INH1and INH2) that can be sed to disable power conversion,
resltin in a very low qiescent inpt crrent and no enerationof switchin noise. An active low (<0.8 volts) is reqired to inhibit
the converter between INH1 (pin 4) and Inpt Common (pin
2). An active low (<0.5 volts) is reqired to inhibit the converterbetween INH2 (pin 12) and Otpt Common (pin 8).
Sync
Converters may be synced to an eternal clock (525 to 675 kHz)
or to one another by sin the sync in or ot pins. The nominalfree-rn switchin freqency is 600 kHz.
current Share anD Parallel OPeratiOn
Mltiple SMFL converters may be sed in parallel to drive acommon load (see Fire 2). Only sinle otpt models with
SENSE and SNS RTN can be sed in the share mode. In thismode of operation the load crrent is shared by two or three
Features
p w , 3 ( 185 w)
• Operatin temperatre -55° to +125°C
• Qalified to MIL-PRF-38534 Class H and K
• Radiation hardness assrance (RHA) to level R 100 kRad(Si)
• Inpt voltae rane 16 to 40 VDC
• Transient protection 80 V for 50 ms
• Flly isolated, manetic feedback
• Fied hih freqency switchin
• Remote sense and otpt trim on sinle otpt models
• Inhibit fnction
• Synchronization inpt and otpt• Indefinite short circit protection
• Hih power density with p to 85% efficiency
MODELS
VDc OutPut
SINgLE3.35
1215
DuAL±5±12
±15
The information in this docment is a derivative of docments cleared
by the Department of Defense (DoD) Office of Secrity Review (OSR) for pblic release.OSR case nmbers 09-S-0996 dated March 13, 2009 and 09-S-1960 dated Jne 22, 2009.
Crane Aerospace & Electronics Power Solutions
SMFL Single and Dual DC/DC Converters
Pae 1 of 14
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
Crane Aerospace & ElectronicsPower Solutions – Interpoint Products10301 Willows Rd. NE, Redmond, WA 98052+1.425.882.3100 • [email protected]
www.craneae.com/interpoint
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 2/14
operating conditions and characteristics
i V r
•16 to 40 VDC continos
•80 V for 50 ms transient
o pw
•40 to 65 watts dependin on model
l s t (10 )
•300°C
s t r (c)
•-65°C to +150°C
pw d (p)
•14 watts (16 watts SMFL2805S, SMFL2805D)
c o t (t)
• -55°C to +125°C fll power
d o pw/c
•Linearly from 100% at 125°C to 0% at 135°C
o V t cff
•100 ppm/°C typical
i o c
•150 pF, typical
c l
•125% of fll load typical
i
•100 meohm minimm at 500 V
a rj
•50 dB typical
cv Fq (-55°c 125°c)
•Free rn mode 600 kHz typical
‣525 kHz. min, 675 kHz ma
mechanical and enVironmental
sz (x)•3.005 1.505 0.400 inches (76.33 38.23 10.16 mm).
Case u has short, straiht leads. Case V has loner leads
which are bent down.
W (x)
•86 rams
sSpace Prototype (O), Class H, or Class K are radiation tolerant
to Radiation Hardness Assrance (RHA) levels of “-” (O), “P,”
or “R,” per MIL-PRF-38534. Interpoint model nmbers se an“O” in the RHA desinator position to indicate the “-” (dash)
Radiation Hardness Assrance level of MIL-PRF-38534, which isdefined as “no RHA”.
•Available confirations: OO, HP, KP, HR, KR.
•See Screenin Tables 1 and 2 for more information.
sync and inhibit (inh1, inh2)
s
•
Sync In ‣ Inpt freqency 525 to 675 Hz. ‣ Dty cycle 40% min, 60% ma
‣ Active low 0.8 V ma ‣ Active hih 4.5 V min, 5 V ma
‣ Referenced to inpt common
•Sync Ot
‣ Referenced to inpt common
i: inh1 inh2
( v )
•Converter Disabled (active low)
‣ INH1 referenced to inpt common
- Pll voltae to 0.8 V or below by connectin to rond or
other method.
- Inhibit pin sorce crrent, 10 mA ma‣ INH2 referenced to otpt common
- Pll voltae to 0.5 V or below by connectin to rond or
other method.
- Inhibit pin sorce crrent 5 mA ma
•Converter Enabled (active hih)
‣ Inhibit pin open or throh an open collector ‣Open pin voltae
- INH1 = 9 to 12 V
- INH2 = 9 V ma
SMFL converters. In crrent sharin mode, one SMFL converteris desinated as a master. The SLAVE pin (pin 11) of the master
is left nconnected and the MSTR/INH2 pin (pin 12) of the masteris connected to the SLAVE pin (pin 11) of the slave nits. The
nits desinated as slaves have the MSTR/INH2 pin (pin 12)connected to the SNS RTN pin (pin 9). Note that synchronizinthe nits toether is not reqired for crrent sharin operation.
A second slave nit may be placed in parallel with a master andslave; this reqires the TRI pin (pin 3) of the master nit to be
connected to the SNS RTN pin (pin 9). See Fire 2 for a blockdiaram of parallel connections.
When paralleled, p to 95% of the total combined power ratinsof the SMFL converters is available at the load. Overload and
short circit performance are not adversely affected drinparallel operation.
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 2 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 3/14
single output models connection diagrams - trim, sense and parallel
RL
1
2
3
4
5
6
REMOTE SENSE CONNECTION
12
11
10
9
8
7
–
+
28V –
+
Inhibit
Sync In
RL
1
2
3
4
5
6
OUTPUT VOLTAGE ADJUST CONNECTION
12
11
10
9
8
7
–
+
28V –
+
Inhibit
Sync In
RA
Positive Input
Input Common
TR1
INH1
Sync Out
Sync In
MSTR/INH2
Slave
Pos. Sense
Sense Return
Output Common
Positive Output
Positive Input
Input Common
TR1
INH1
Sync Out
Sync In
MSTR/INH2
Slave
Pos. Sense
Sense Return
Output Common
Positive Output
Figure 1: SenSe cOnnectiOnS anD trim table – Single OutPut mODelS
RL
1
Positive Input
Input Common
TR1
INH1
Sync Out
Sync In
2
3
4
5
6
1
2
3
4
5
6
1
2
3
45
6
CONNECT ONLY WHEN 2 SLAVES ARE USED
12
11
10
9
8
7
12
11
10
9
8
7
12
11
10
98
7
–
+
MSTR/INH2
Slave
Pos. Sense
Sense Return
Output Common
Positive Output
MASTER
SLAVE 1
SLAVE 2
28V–
+
Inhibit
Sync In
Positive Input
Input Common
TR1
INH1
Sync Out
Sync In
MSTR/INH2
Slave
Pos. Sense
Sense Return
Output Common
Positive Output
Positive Input
Input Common
TR1
INH1
Sync Out
Sync In
MSTR/INH2
Slave
Pos. Sense
Sense Return
Output Common
Positive Output
Figure 2: Parallel cOnnectiOnS – Single OutPut mODelS
Notes:1. When sin remote sense for voltae
compensation or when sin remote sensefor trim, the otpt will drift over temperatre.Contact Applications Enineerin for moreinformation [email protected].
2. Do not eceed the maimm rated power.
Notes1. No one converter may carry more than its maimm rated crrent.2. Althoh p to 95% of the maimm crrent of paralleled converters is available, individal converter operation, load and layot may
affect the actal crrent shared. Contact Applications Enineerin for more information [email protected].
VOut
increaSe ra
(OhmS)
VOltS 3.3 V 5 V 12 V 15 V
0.1 66 77 27 21
0.2 131 153 55 43
0.3 196 230 82 64
0.4 262 307 109 86
0.5 349 396 139 109
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 3 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 4/14
Figure 3: Pin Out
Angled corner indicates pin one.
1
2
3
4
5
6
12
11
10
9
8
7
TOP VIEW
SMFL
(Pin side, marked side)
See cases u and V for dimensions.Case V has the same pin ot.
pin out
p s o d o
1 Positive Inpt Positive Inpt
2 Inpt Common Inpt Common
3 Triple (TR1) Triple (TR1)
4 Inhibit 1 (INH1) Inhibit 1 (INH1)
5 Sync Ot Sync Ot
6 Sync In Sync In
7 Positive Otpt Positive Otpt
8 Otpt Common Otpt Common
9 Sense Retrn Neative Otpt
10 Positive Sense No connection
11 Slave Slave
12Master/Inhibit 2(MSTR/INH2)
Master/Inhibit 2(MSTR/INH2)
pins not in use
p d a
3 TR1 Leave nconnected
4 Inhibit 1 (INH1) Leave nconnected
5 Sync Ot Leave nconnected
6 Sync InConnect to Inpt
Common
9 Sense RetrnConnect to appropriate
otpts
10 Positive SenseConnect to appropriateotpts
11 Slave Leave nconnected
12 Master/Inhibit 2(MSTR/INH2) Leave nconnected
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 4 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 5/14
model numbering key
SMFL 28 05 S V / K RBase Model
Input Voltage
Output Voltage
Screening
Number of Outputs(S = single, D = dual)
Case Option(leave blank for standard case U)
Radiation HardnessAssurance (RHA)
smd numbers
Standard Microcircuit
drawing (SMd)
5962R0621302KxC5962R9316302KxC5962R9316202KxC5962R9316102KxC5962R9319102KxC5962R9319202KxC5962R9319302KxC
SMFL SerieS SiMiLar Part
SMFL283R3S/KRSMFL2805S/KRSMFL2812S/KRSMFL2815S/KRSMFL2805D/KRSMFL2812D/KRSMFL2815D/KR
The SMD nmber shown is for Class H screenin, non-flaned,and no Radiation Hardness Assrance (RHA) level. See theSMD for the nmbers for other screenin and RHA levels.For eact specifications for an SMD prodct, refer to the SMDdrawin. SMDs can be down-loaded from:http://www.dscc.dla.mil/prorams/smcr
model selection
on the LineS beLow, enter one SeLection FroM each category to deterMine the ModeL nuMber.
category
smFl28 ___________ / _______
Base Model andInpt Voltae
Otpt Voltae 1 Nmber of Otpts 2 Case/LeadOptions 3
Screenin 4 RHA 5
3r3, 05, 12, 15 s (u, leave blank) o o
SMFL28 is the onlyavailable option
05, 12, 15 d V h p
selection k r
Notes:1. Otpt Voltae: An R indicates a decimal point. 3R3 is 3.3 volts ot.2. Nmber of Otpts: S is a sinle otpt and D is a dal otpt
3. Case Options: For the standard case (case u) leave the case option blank. For case option V, insert the letter V in the case option position.4. Screenin: A screenin level of O is a Space Prototype and is only sed with RHA O. See Screenin Tables 1 and 2 for more information.5. RHA: Interpoint model nmbers se an “O” in the RHA desinator position to indicate the “-” (dash) Radiation Hardness Assrance level of MIL-PRF-
38534, which is defined as “no RHA.” RHA O is only available with Screenin level O. See Screenin Table 2 for more information.
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 5 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 6/14
Notes
1. g , .2. unit will sht down above approimately 45 V bt will be ndamaed and will
restart when voltae drops into normal rane.3. Recovery time is measred from application of the transient to point at
which VOuT is within 1% of final vale.
4. Tested on release from inhibit.5. Shall not compromise DC performance.
Electrical Characteristics: -55°C to +125°C TC, 28 VDC Vin, 100% load, RHA level O, nless otherwise specified.
SINgLE OuTPuT MODELS SMFL283R3S SMFL2805SunitS
Parameter cOnDitiOnS MIN TYP MAx MIN TYP MAxOutPut VOltage 3.21 3.30 3.39 4.87 5.00 5.13 VDc
OutPut current Vin = 16 tO 40 VDc 0 — 12.12 0 — 10 a
OutPut POWer Vin = 16 tO 40 VDc 0 — 40 0 — 50 W
OutPut riPPle
10 khz - 2 mhz
tc = 25°c — 10 35 — 15 35mV p-p
tc = -55°c tO +125°c — 10 50 — 30 50
line regulatiOn Vin = 16 tO 40 VDc — 0 20 — 0 20 mV
lOaD regulatiOn nO lOaD tO Full — — 40 — — 20 mV
inPut VOltage cOntinuOuS 16 28 40 16 28 40 VDc
TRANSIENT 50 ms 1,2 — — 80 — — 80 V
inPut current nO lOaD — 70 100 — 70 120
inhibiteD – inh1 — 9 14 — 9 14 mA
inhibiteD – inh2 — 35 70 — 35 70
inPut riPPle 10 khz - 10 mhz — 30 50 — 30 50 mA p-p
eFFiciency tc = 25°c 71 — — 75 78 —%
tc = -55°c tO +125°c 69 — — 73 — —
lOaD Fault ShOrt circuit
POWer DiSSiPatiOn— 12.5 16 — 12.5 18 W
recOVery 1 1.5 6 1.5 4 ms
SteP lOaD reSPOnSe 50% - 100% - 50%
tranSient— ±200 ±300 — ±250 ±350 mV pk
recOVery 1, 3 — 1.5 3.0 — 1.5 3.0 ms
SteP line
reSPOnSe 1, 316 - 40 -16 VDc
tranSient — ±250 ±300 — ±250 ±300 mV pk
recOVery — 200 300 — 200 300 µs
Start-uP 4 Delay — 3.5 10 — 3.5 6 ms
CAPACITIVE LOAD 5 tc = 25°c — — 1000 — — 1000 µF
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 6 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 7/14
SINgLE OuTPuT MODELS SMFL2812S SMFL2815SunitS
Parameter cOnDitiOnS MIN TYP MAx MIN TYP MAxOutPut VOltage 11.76 12.00 12.24 14.55 15.00 15.45 VDc
OutPut current Vin = 16 tO 40 VDc 0 — 5 0 — 4.33 a
OutPut POWer Vin = 16 tO 40 VDc 0 — 60 0 — 65 W
OutPut riPPle
10 khz - 2 mhz
tc = 25°c — 0 75 — 30 85mV p-p
tc = -55°c tO +125°c — 45 100 — 45 110
line regulatiOn Vin = 16 tO 40 VDc — 0 20 — 0 20 mV
lOaD regulatiOn nO lOaD tO Full — — 40 — — 20 mV
inPut VOltage cOntinuOuS 16 28 40 16 28 40 VDc
TRANSIENT 50 ms 1,2 — — 80 — — 80 V
inPut current nO lOaD — 50 100 — 50 100
inhibiteD – inh1 — 9 14 — 9 14 mA
inhibiteD – inh2 — 35 70 — 35 70
inPut riPPle 10 khz - 10 mhz — 30 50 — 30 50 mA p-p
eFFiciency tc = 25°c 81 84 — 82 85 —%
tc = -55°c tO +125°c 79 — — 80 — —
lOaD Fault ShOrt circuit
POWer DiSSiPatiOn— 10 16 — 10 16 W
recOVery 1 1.5 4 1.5 4 ms
SteP lOaD reSPOnSe 50% - 100% - 50%
tranSient— ±450 ±600 — ±500 ±600 mV pk
recOVery 1, 3 — 1.5 3.0 — 1.5 3.0 ms
SteP line
reSPOnSe 1, 3
16 - 40 -16 VDc
tranSient — ±250 ±400 — ±250 ±500 mV pk
recOVery — 200 300 — 200 300 µs
Start-uP 4 Delay — 3.5 6 — 3.5 6 ms
CAPACITIVE LOAD 5 tc = 25°c — — 1000 — — 1000 µF
Notes1. g , .2. unit will sht down above approimately 45 V bt will be ndamaed and will
restart when voltae drops into normal rane.3. Recovery time is measred from application of the transient to point at
which VOuT is within 1% of final vale.
4. Tested on release from inhibit.5. Shall not compromise DC performance.
Electrical Characteristics: -55°C to +125°C TC, 28 VDC Vin, 100% load, RHA level O, nless otherwise specified.
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 7 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 8/14
Notes1. g , .2. Parallel load share fnction is not characterized for dal otpt models.3. up to 70% of the total otpt power is available from either otpt providin the
opposite otpt is simltaneosly carryin 30% of the total power.4. Effect on neative Vot from 50%/50% loads to 70%/30% or
30%/70% loads.5. Effect on neative Vot from 50%/50% loads to 50% then 10% load on neative
Vot.
6. unit will sht down above approimately 45V bt will be ndamaed and willrestart when voltae drops into normal rane.
7. Recovery time is measred from application of the transient to point at which Votis within 1% of final vale.
8. Tested on release from inhibit.9. Shall not compromise DC performance.
Electrical Characteristics: -55°C to +125°C TC, 28 VDC Vin, 100% load, RHA level O, nless otherwise specified.
DuAL OuTPuT MODELS 2 SMFL2805D SMFL2812D SMFL2815DunitS
Parameter cOnDitiOnS min tyP maX min tyP maX min tyP maXOutPut VOltageVin 16 tO 40 VDc
+VOuT 4.85 5.00 5.15 11.64 12.00 12.36 14.55 15.00 15.45VDc
-VOuT 4.82 5.00 5.18 11.58 12.00 12.42 14.47 15.00 15.53
OutPut current 2, 3
Vin 16 tO 40 VDcEACH OuTPuT 0 — 7 0 — 3.5 0 — 3.03
aTOTAL 0 — 10 0 — 5 0 — 4.33
OutPut POWer 2 Vin = 16 to 40 VDC 0 — 50 0 — 60 0 — 65 W
OutPut riPPle 10 kHz - 2 MHz ± VOut — 50 100 — 50 120 — 50 150 mV p-p
line regulatiOnVin 16 tO 40 VDc
+VOuT — 0 50 — 0 50 — 0 50mV
-VOuT — 25 100 — 25 100 — 25 100
lOaD regulatiOn
nO lOaD tO Full
+VOuT — 0 50 — 0 50 — 0 50mV
-VOuT — 25 100 — 50 120 — 50 150
crOSS regulatiOn
tc = 25°c
SEE NOTE 4 — 5 8 — 2 4 — 2 4%
SEE NOTE 5 — 3 6 — 2 4 — 2 4
inPut VOltage +VOuT 16 28 40 16 28 40 16 28 40 VDc
TRANSIENT 50 ms 1, 6 — — 80 — — 80 — — 80 V
inPut current NO LOAD — 50 120 — 50 100 — 50 100
INHIBITED–INH1 — 9 14 — 9 14 — 9 14mA
INHIBITED–INH2 — 35 70 — 35 70 — 35 70
inPut riPPle current 10 khz - 10 mhz — 30 50 — 30 50 — 30 80 mA p-p
eFFiciency tc = 25°c 75 78 — 81 84 — 82 85 —%
balanceD lOaD tc = -55°c tO +125°c 73 — — 79 — — 80 — —
lOaD Fault ShOrt circuitPOWer DiSSiPatiOn — 12.5 18 — 10 16 — 10 16 W
recOVery 1 — 1.5 4.0 — 1.5 4.0 — 1.5 4.0 ms
SteP lOaD reSPOnSe
± VOut
50% - 100% - 50%tranSient
— ±250 ±350 — ±450 ±600 — ±500 ±600 mV pk
recOVery 1, 7 — 1.5 3.0 3.0 1.5 3.0 1.5 3.0 ms
SteP line reSPOnSe 1
± VOut
16 - 40 -16 VDc
tranSient— ±250 ±300 — ±250 ±400 — ±250 ±500 mV pk
recOVery 7 — 200 300 — 200 300 — 200 300 µs
Start-uP 8 Delay — 3.5 6 — 3.5 6 — 3.5 6 ms
caPacitiVe lOaD 9 tc = 25°c — — 500 — — 500 — — 500 µF
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 8 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 9/14
Typical Performance Crves: 25°C Tc, 28 VDC Vin, 100% load, free rn, nless otherwise specified.
Output (Watts)
SMFL2805S & SMFL2805D Efficiency
E f f i c i e n c y ( % )
60
90
85
80
75
70
10 20 30 40 50
28V
40V
65
16V
Figure 4
Output Power (Watts)
SMFL2812S & SMFL2812D Efficiency
E f f i c i e n c y ( % )
60
90
85
80
75
70
10 20 30 40 50 60
40V
16V
65
28V
Figure 5 Figure 6
60
90
85
80
75
70
10 20 30 40 50 6560
65
16V
Output Power (Watts)
SMFL2815S & SMFL2815D Efficiency
E f f i c i e n c y ( % )
40V
28V
Figure 7 Figure 9
60
65
70
75
80
85
90
0 10 20 30 40 50 60 70
40 VIN
16 VIN
28 VIN
Output Power (Watts)
SMFL2828S Efficiency
E f f i c i e n c y ( % )
50 s/div
16 to 40 V
SMFL2805S Step Line Response
1 0 0 m V / d i v .
2 0 V / d i v .
Vout
Vin
0.1
0.
20.
40.
60.
80.
100.
A t t e n u a t i o n
( d B )
Frequency (kHz)
SMFL Series Audio Rejection
1 10 100
Figure 8
1 0 0 m V / d i v .
100% to 50%
50% to 100%
1ms/divSMFL2805S Step Load Response
Figure 10
1ms/divNo Load
SMFL2805S Turn On Response
1 V / d i v .
2 0 V / d i v .
Vin
Vout
Figure 11 Figure 12
50 s/div16 to 40 V
SMFL2815D Step Line Response
1 0 0 m V / d i v .
+Vout
–Vout
Vin
2 0 V / d i v .
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 9 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 10/14
Figure 13 Figure 15
1ms/div
SMFL2815D Step Load Response
2 0 0 m V / d i v .
100% to 50%
50% to 100% –Pout = 32.5W
0
30 40 50 60 – 8
– 6
– 4
– 2
2
4
6
8
SMFL2812D
SMFL2805D
70
SMFL2815D
Positive Output Load (% of Total Load)
-VOUT
with shift in load balance
Cross Regulation
– V o u t V o l t a g e C h a n g e ( % )
5 V / d i v .
2 0 V / d i v .
VIN
–Vout
+Vout
1ms/div
No Load
SMFL2815D Turn On Response
Figure 14
Figure 16
10 20 30 40 50 6011
15
14
13
12
65
16
SMFL2815S & 15D
SMFL2805S & 5D
Output Power (Watts)
Low Line Dropout
I n p u t V o l t a g e
( V o l t s )
SMFL2812S & 12D
Typical Performance Crves: 25°C Tc, 28 VDC Vin, 100% load, free rn, nless otherwise specified.
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 10 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 11/14
Angled cornerindicates pin one.
1
2
3
4
5
6
12
11
10
9
8
7
0 . 0
0 0
0 . 0
5 0 ( 1 . 2
7 )
0.000
0.120 (3.05)
0.250 (6.35)
0.450 (11.43)
0.650 (16.51)
0.850 (21.59)
1.050 (26.67)
1.250 (31.75)
1.380 (35.05)
1.505 (38.23) max.
0 . 0
0 0
0 . 1
2 0 ( 3 . 0
5 )
0 . 2
5 0 ( 6 . 3
5 )
2 . 7
5 0 ( 6 9 . 8
5 )
2 . 8
8 0 ( 7 3 . 1
5 )
3 . 0
0 5 ( 7 6 . 3
3 ) m a x .
0.128 dia(3.25).
0.040 dia(1.02)
0.23 (5.8) Pin Length
0 . 4
0 0 ( 1 0 . 1
6 ) m a x .
0 . 2
2 0 ( 5 . 5
9
TOP VIEW CASE U*
Flanged case, short-leaded
Seam Seal
*Does not require designator in Case Option position of model number.
Weight: 86 grams maximum
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places±0.01 (0.3) for two decimal placesunless otherwise specified
CAUTIONHeat from reflow or wave soldering may damage the device. Solder pinsindividually with heat application not exceeding 300°C for 10 seconds per pin.
MaterialsHeader Cold Rolled Steel/Nickel/GoldCover Kovar/NickelPins #52 alloy/Gold, compresssion glas seal
Seal Hole: 0.120 ±0.002 (3.05 ±0.05)
Case U, Rev G, 2012.06.15Please refer to the numerical dimensions for accuracy.
Figure 17: caSe u
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 11 of 14
SMFL Single and Dual DC/DC Converter Cases
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 12/14
0 . 0
0 0
0 . 2
2 0 ( 5 . 5
9 )
0 . 0
5 0 ( 1 . 2
7 )
0 . 4
0 0 ( 1 0 . 1
6 ) m a x
r e f : 0 . 2
5 0 ± 0 . 0
5 0
( 6 . 3
5 ± 1 . 2
7 )
r e f : 0 . 2
2 5 ( 5 . 7
2
3.45 (87.6) Reference(lead center to lead center)
0.000
0.120 (3.05)
0.250 (6.35)
0.450 (11.43)
0.650 (16.51)
0.850 (21.59)
1.050 (26.67)
1.250 (31.75)
1.380 (35.05)
0 . 0
0 0
0 . 1
2 0 ( 3 . 0
5 )
0 . 2
5 0 ± 0 . 0
1 0
( 6 . 3
5 ± 0 . 3
)
2 . 7
5 0 ( 6 9 . 8
5 )
2 . 8
8 0 ( 7 3 . 1
5 )
0.128 dia(3.25)
0.040 dia(1.02)
Flanged case, down leaded
*Designator "V" required in Case Option position of model number.
1
2
3
4
5
6
12
11
10
9
8
7
Maximum dimensions: 3.005 x 1.505 (76.33 x 38.23 mm)Angled corner
indicates pin one.
3 . 0
0 5 ( 7 6 . 3
3 ) m a x
Weight: 86 grams maximum
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places±0.01 (0.3) for two decimal placesunless otherwise specified
CAUTIONHeat from reflow or wave soldering may damage the device. Solder pinsindividually with heat application not exceeding 300°C for 10 seconds per pin.
MaterialsHeader Cold Rolled Steel/Nickel/GoldCover Kovar/NickelPins #52 alloy/Gold, compresssion glas seal
Seal Hole: 0.120 ±0.002 (3.05 ±0.05)
Case V, Rev G, 2012.06.15Please refer to the numerical dimensions for accuracy.
Seam Seal
Figure 18: caSe V
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 12 of 14
SMFL Single and Dual DC/DC Converter Cases
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 13/14
Screening table 1: element eValuatiOn
dc-dc conVerterS PrototyPe, cLaSS h and cLaSS K,
MiL-PrF-38534 eLeMent eVaLuation non-QML 1 QML
PrototyPe cLaSS h cLaSS K
coMPonent-LeVeL teSt PerForMed
/o /h /K
M/S 2 M/S 2 P 3 M/S 2 P 3
Element Electrical n n n n n
Visal n n n n
Internal Visal n n
Temperatre Cyclin n n
Constant Acceleration n n
Interim Electrical n
Brn-in n
Post Brn-in Electrical n
Steady State Life n
Voltae Conditionin Ain n
Visal Inspection n
Final Electrical n n n n
Wire Bond Evalation n n n n
SEM n
Notes:1. Non-QML prodcts may not meet all of the reqirements of MIL-PRF-38534.2. M/S = Active components (Microcircit and Semicondctor Die)3. P = Passive components, Class H and K element evalation. Not applicable to Space Prototype (“O”) element evalation.
Definitions:Element Evalation: Component testin/screenin per MIL-STD-883 as determined by MIL-PRF-38534SEM: Scannin Electron Microscopy
Crane Aerospace & Electronics Power Solutions
www.craneae.com/interpoint Pae 13 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
SMFL Rev AA - 2012.03.19
7/28/2019 DC-DC Converter 400 Bad Request 400 Bad Request nginx/1.2.9
http://slidepdf.com/reader/full/dc-dc-converter-400-bad-request- 14/14
Screening table 2: enVirOnmental Screening
Table is for reference only. See individal Series datasheets for specific screenin.
dc-dc conVerterS PrototyPe, cLaSS h and cLaSS K
MiL-PrF-38534 enVironMentaL Screening and rha1 P or r
non-QML 2 QML 3
PrototyPe cLaSS h cLaSS K
teSt PerForMed /oo /hP /hr /KP /Kr
n- w , m 2023 n 4 n 4 n n
p- i, m 2017, 2032 n n n n n
t c (10 )
Method 1010, Cond. C, -65°C to +150°C, ambient n n n n n
c a
Method 2001, 3000 (Qal 5000 ) n n n n n
pind, t m 2020, c. a n 4 n 4 n n
p - , g a, s 1 4 n n 4 n 4 n n
b- m 1015, +125°c , 5
96 hors n
160 hors n n
2 160 hors (incldes mid-BI test) n n
F e t, mil-prF-38534, g a,
Sbrops 1 and 4: +25°C case n
Sbrops 1 throh 6, -55°C, +25°C, +125°C case n n n n
h tgross Leak, Method 1014 n n n n n
Fine Leak, Method 1014 n n n n n
r, m 2012 n n
p r e t, +25°c n 4 n 4
F v , m 2009 n n n n n
rha p: 30 (s) n n
rha r: 100 (s) n n
see let 40 mV-2 / n n n n
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Notes:1. Or Redmond facility has a DLA approved RHA plan for Interpoint power
prodcts. Or SMD prodcts with RHA “P” or “R” code meet DLA reqirements.2. “OO” prototypes are non-QML prodcts and may not meet all of the reqirements
of MIL-PRF-38534. “O” in the RHA desinator position in Interpoint modelnmbers indicates DLA RHA “-” defined as no RHA.
3. All processes are QML qalified and performed by certified operators.4. Not reqired by DLA bt performed to assre prodct qality.5. Brn-in temperatre desined to brin the case temperatre to +125°C minimm.
Brn-in is a powered test.
Crane Aerospace & Electronics Power Solutions
SMFL Sinle and Dal, SMFL Rev AA - 2012.03.19. This revision spersedes all previos releases. All technical information is believed to be accrate,bt no responsibility is assmed for errors or omissions. Crane Electronics, Inc. reserves the riht to make chanes in prodcts or specificationswithot notice. SMFL Series is a trademark of Crane Electronics, Inc. Copyriht © 1999 - 2013. Crane Electronics, Inc. All rihts reserved.www.craneae.com/interpoint
Pae 14 of 14
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt