    SPC Operating and Maintenance Instruction

    SHENWU

     

    Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

      :1.1

  • 8/18/2019 DC Pump Manual

    2/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 1 -

    Introduction

    Thanks your purchase the SPC series of PV solar water pumps!

    This instruction introduces the right installation and usage of SPC products. Please

    read the instruction carefully before installation, application, maintenance and inspection.

    Cautions

      Upon opening please confirm :① water pump control system model, motor model is

    consistent with your order.②   the product certificate, user manual and warranty and

    other accessories are complete.③ If there is any breakage phenomenon, if found to be

    damaged, missing or damage, please contact with the company or your supplier to

    solve.

      The differences between explanatory pictures and real products do caused by the great

    varieties of SPC series pump.

      Because the product upgrades and specification upgrades, as well as to improve the

    accuracy, the instruction will be updated in a timely manner, please note the current

    version is the latest version before reading.

      If you have any query after reading this instruction, please contact our customer service.

      Customer service Tel:+86 132 0371 5884

  • 8/18/2019 DC Pump Manual

    3/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 2 -

    SPC Operating and Maintenance Instruction

    Contents

    1. Security Information -----------------------------------------------------------   3

    2. Brief Description ---------------------------------------------------------------- 6

    3. Product Introduction ----------------------------------------------------------- 6

    4. Type Instruction ----------------------------------------------------------------   7

    5. SPC controller parameter ----------------------------------------------------- 7

    6. Machine & Electricity installation ------------------------------------------- 8

    7. Operation Declaration --------------------------------------------------------- 16

    8. Working Conditions ------------------------------------------------------------- 17

    9. Maintenance --------------------------------------------------------------------- 17

    10.Trouble shooting ---------------------------------------------------------------- 18

    Warranty Agreement---------------------------------------------------------------- 19

  • 8/18/2019 DC Pump Manual

    4/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 3 -

    1. Security Information

    Security Definition:There are two kinds of security attentions in this instruction:

    Danger:The danger caused by the wrong operation on one’s own, may lead to heavy hurt or death.

    Warning:The danger may result in moderate hurt or minor injury, and equipment’s damage.

    Before you install, adjust and maintenance this system, please read this chapter carefully, and please bring your

    attentions to the safety rules in this chapter. Our company has nothing to do with any damage caused by violations.

    1.1 Before installation:

    Danger

      Please don’t install when unpacking found controller waterlogged, components or parts damaged!

      Please don’t install when the real goods don’t conform to the specifications in PL!

      Please handle the equipment gently, protect the equipment from damage.

      Please don’t install or use when system control box installed components have defects or

    deformation of the abnormal situation!

      Please don’t touch controller components by hands, or there is electrostatic damage risk!

    1.2 Installation:

    Danger

      Please install controller indoors, or rain, moisture proof outdoor mounting bracket (or

    installation covering)!

      Controller installation area should away from combustible materials, or may cause a fire!

      Installing the controller fixed supports or mounting screws must be solid, otherwise the device

    my fall and lead to dangerous incidents!

      Submersible pump installation should be install lifting rope for lift hole, does not allowed pump

    motor cable pulling, or the cables may be pull apart, pump falls and other unpredictable danger!

    Warning

      Can’t let the wire head, screws and other conductive objects fall into the controller; otherwise

    it may cause damage to the controller.

      Please install the control in the place with less shake and avoid direct sunlight.

      Please note the installation location to ensure the cooling effect.

      Please note the submersible depth of pump should no less than 0.5 meters, or may cause the

    pump burned out!

    1.3 Wiring:

  • 8/18/2019 DC Pump Manual

    5/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 4 -

    Danger

      Please carefully read the manual, and by professional electrical engineer operate, or may cause

    a danger!

      Before connection, please confirm the controller is without power, or may cause electric shock risk.

      Please follow the manual figure and description to connect wires , otherwise may cause safety

    accident!

      Pay attention to the cross-sectional area of power supply line and water pump connecting cable

    can meet the real needs, or may cause safety accident!

      Please according to the standard operate the controller in a right way; otherwise there is a risk

    of electric shock!

      Never be the input power is connected to the output terminals (U,V,W), take notice of the

    terminals mark, don’t pick the wrong line, or may cause a controller damage!

      Note the DC input line (+), (-) polarity can not be reversed, or to cause the machine to burned or

    more serious accidents!

      If the pump cable joints under water, please make sure that the underwater joint waterproof 

    treatment is safe and reliable, otherwise it may result in damage to the equipment or more

    serious safety accidents!

      Ensure the distribution lines tally with the EMC requirements and local safety standard. The wire

    size please refer to the manual’s proposal, otherwise may occur safety accident!

    Warning

      Electric motor input lines (U V W) must be connected correctly, otherwise the motor run in

    opposite direction. And the pump would not pump water.

      Note the high or low position of water level sensor, to set right gap control, avoid frequent reboot.

    1.4 Before power on:

    Danger

      Ensure the input voltage in the rated voltage range of controller, otherwise may cause damage

    to the machine or more serious consequences!

      Please confirm all terminals connected firmly, without loosing and fastening won’t cause big

    contract resistance, otherwise may cause the dangerous risk!

      Please don’t use wet hands to touch the wires, terminals, switches, controllers, or may result in

    damage to the equipment or cause unpredictable consequences!

    Warning

      Please confirm the output (U V W) wiring position is correct, otherwise the motor run reversely

    or other accidents!

      Check the external wiring whether has a short-circuit phenomenon, or may cause the controller

    is damaged!

      Don’t need to make any pressure test on any part of controller,or may lead to the accident!

      Submerge the pump into the water for 15-20 minutes before first use. No dry runs. Or may cause

    the pump burned out!

    1.5 After power on:

  • 8/18/2019 DC Pump Manual

    6/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 5 -

    Danger

      Don’t use hands to touch controller wiring terminals, cables and etc, or there is a risk of electric

    shock!

      If the parameters need to be measured, please confirm and check whether the safety measures

    is normal. Please attention any part of the body can not touch the charged terminal metal part,

    otherwise may cause an electric shock risk!

      If need to test and adjust machine, please note that the pump is completely immersed in the

    water and well fixed, or may lead to unpredictable accidents!

      Don’t collate or pull cables after power on, or may cause dangerous risk!

    Warning

      Don’t frequently switch controller, or it may cause damage to the machine!

    1.6 In operation:

    Danger

      Amateur technicians can not detect signal in operation, or it may cause personnel injury or

    equipment damage!

      Please do not touch to test the temperature of the equipment, or may cause burns or other

    accidents!

    Warning

      Avoid something or debris falls into the device, or it may cause damage to equipment or other

    unpredictable accidents!

      Don’t take the contactor (air switch on-off method) to control the start-stop of device, or easily

    damage the switch!

      Please note the intermittent start-stop time should not be less than 2 minutes, or may cause

    damage to the machine!

    1.7 Maintenance:

    Danger

      Don’t repair and maintenance the charged equipment, or there is a risk of electric shock!

      In equipment downtime and shut off external power supply after 2 minutes to make the

    maintenance and repair, or the residual charge on capacitor may cause harm to human body!

      Non-professionally trained technician can not repair or maintenance the controller, or may cause

    personal injury or equipment damage!

    2. Brief Description

  • 8/18/2019 DC Pump Manual

    7/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 6 -

    PV water pumping system is mainly composed of: solar water pump controller, pump, solar array and corresponding

    connecting pipelines and cables, as shown in Fig2.1. Mainly used for lifting water, lakes, rivers and other water sources,

    and used for agricultural irrigation, aquaculture, city greening, living water supply, water conservancy project. PV

    water pumping system highlights its advantages in those areas where rich in solar energy resources but lack of city

    electricity supply. Our company produces the SPC series DC photovoltaic pump system having the advantages of 

    environmental protection, high efficiency, unattended, and maintenance-free characteristics, which is an ideal green

    environmental protection product.

    Fig2.1 schematic diagram of PV water pumping system

    3. Product Introduction

    The SPC series PV pump system consists of: solar water pump controller, DC motor, solar array and corresponding

    connecting pipelines and cables. This series product has the following advantages:

      The DC PM brushless motor increases the efficiency up to 25% in comparison with traditional AC motor.

      Adopt stator and rotor double plastic patented technology to do plastic insulation waterproofing treatment.

    Motor insulation degree is larger than 300M ohm; greatly enhance the safety and reliability of motor.

      The water lubricated bearing, relative to conventional bearings, has the advantages of easy installation, no

    environmental pollution.

      The microprocessor controller has advantages of MPPT, double water level detection control; prevent dry play

    protection, automatic operation (unattended), etc.

    SPC series solar water pump controller can be driven by solar array or battery. Customers can choose to purchase

    controller with charging function, and join the battery to compose a system working 24 hours. The company can tailor

    the PV pump system based on the actual needs the user.

    4. Type Instruction

  • 8/18/2019 DC Pump Manual

    8/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 7 -

    Controller Type

    Pump Type:

    5. SPC controller parameter

    SPC controller size:

    Mode

    Dimensions

    (mm)Hole Position (mm)

    Hole

    Dia(mm)Volume

    size(mm)

    L W A B C DSPC-200 218 174 125 94 200.5 Ø6 218*174*109

    SPC-300 218 174 125 94 200.5 Ø6 218*174*109

    SPC-1000 218 174 125 94 200.5 Ø6 218*174*109

    SPC-1500 288 174 125 94 270.5 Ø6 288*174*109

    SPC-2200 288 174 125 94 270.5 Ø6 288*174*109

    SPC-2800 288 174 125 94 270.5 Ø6 288*174*109

    SPC-4200 288 174 125 94 270.5 Ø6 288*174*109

    SPC controller electrical parameter

    SPC-200

    Rated power 200W

    Solahero Pump Controller

    Voltage

    Max flow rate

    Solahero Pump

    SHP-0.7/30-24

    Max head

  • 8/18/2019 DC Pump Manual

    9/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 8 -

    ModelRated power

    (W)

    Operation

    Voltage(V)

    Work voltage

    range   (V)

    Max input

    voltage(V)

    Max power

    current   (A)

    Net weight

    (kg)

    Gross weight

    (kg)

    SPC-200 200 24V 18-30V 36V 8A 1.51 1.95

    SPC-300 300 36V 32-40V 45V 9A 1.51 1.95

    SPC-1000 1000 48V 46-56V 65V 15A 1.53 1.97

    SPC-1500 1500 110V 105-120V 180V 11A 2 2.44

    SPC-2200 2200 280V 270-300V 380V 6A 2.05 2.49

    SPC-3000 3000 290V 280-310V 380V 8A 2.05 2.49

    SPC-4200 4200 300V 290-320V 380V 11A 2.05 2.49

    Warning:

      The total Voc voltage of solar module should not exceed the maximum input voltage of the

    selected controller, or may cause damage.

      The total Vmp voltage of solar module should be in working voltage range of motor, or may cause

    the machine damaged.

    6. Machine and Electricity Installation

    6.1 solar module installations

    6.1.1 solar panel selection:

    Solar panel recommended configuration table

    parameter   SPC-200 SPC-300 SPC-1000 SPC-1500   SPC-2200 SPC-2800 SPC-4200

    Maximum power(W)   210W 300W 200W 195W   270W 300W 240W

    Maximum power voltage   27.6V 38.16V 26.48V 36.75V   36.1V 35V 34.56V

    Open circuit voltage(Voc)   33V 44.64V 32.7V 45.4V   43.6V 41.3V 42.48

    Maximum power current   7.6A 7.87A 7.45A 5.31A   7.48A 8.58A 6.96A

    Required total quantity 1PCS 1PCS 4PCS 6PCS   8PCS 9PCS 18PCS

    Power of solar array(W)   210W 300W 800W 1170W   2160W 2700W 4320W

    6.1.2 solar panel installation:

    Small power solar panel to

    recommend the use of column type

    solar bracket as shown in Fig 6.1:

  • 8/18/2019 DC Pump Manual

    10/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 9 -

    Fig6.1 Column type solar bracket

    Multiple solar panel to recommend the use of array type solar mounting as shown in Fig6.2:

    Fig6.2 array type solar bracket

    Solar array direction and elevation adjustments as shown in Fig6.3,first to adjust the light receiving horizontal area

    face the direction of the sun at noon, then let the sun light (at noon) perpendicular to the light receiving area.

    Fig6.3

    The scientific method is: according to the actual local latitude and checking longitude, by checking table and actual

    geographical situation calculate the horizontal installation direction and elevation, then install based on those

    parameters.

    warning

      Unreasonable direction and elevation will reduce solar energy utilization ratio, thereby reduce

    the efficiency of the system.

      The elevation should change with the seasons and adjustment, especially in the high latitude

    region should adjust the elevation angel to achieve the maximum solar utilization ratio.

    6.2 SPC series controller installation

    6.2.1 Installation environment:

    a) Environment temperature :The temperature has great influence on service life, do not allow it exceeds the

    allowed temperature range(-10℃— 50℃).

    Morning

    Noon

    Evening

    Solar panel

    Solar panel

    Elevation

    Vertical sun

    Noon

    Horizontal plant

  • 8/18/2019 DC Pump Manual

    11/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 10 -

    b) Vertically mounted controller, where there is enough space for cooling.

    c) Install in the place with less vibration,Vibration should be less than 0.6G.

    d) Avoid direct sunlight, humidity and water.

    e) Avoid the corrosive, inflammable, explosive gases in air。

    f) Don’t install in the grease and dusty place.

    6.2.2 Controller installation:

    Mount the controller on the column bracket as shown in Fig6.4, on the wall, electric control boxes and other flat

    surface as shown in Fig6.5.

    Fig6.4 controller mounted on the column type bracke

  • 8/18/2019 DC Pump Manual

    12/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 11 -

    Fig 6.5 Controller mounted on wall and electric control box

    6.3 pump installation

    6.3.1 Pump installation steps:

    a) Prepare sufficient long hoisting cable according to the actual situation and let it go through the water pump

    hoisting hole and fixed by chunk (as shown in Fig6.6). Another end of hoisting cable is fixed to the derrick reel

    or fixing device.

    Fig6.6 hoisting cable installation

    b) According to the actual situation prepare long enough waterproof 3 core cable( cable specifications with

    reference to cable selection guide chapter),Let the cable head and pump lead line respectively pass through

    the waterproof connector of water proof junction box and dock. And remark the U V W 3-phase identification

    on docked waterproof cable. For more details please see under water connection guidance chapter.

    c) Prepare a suitable water pipes to meet real needs( note the nominal pressure of the water pipes and pipe

    fittings should be greater than the actual working pressure).Wind the outside wire connector with plastic

    stripe then screw it into the outlet of water pump and connect.

    d) Extend the cables of probe-type sensor or float sensor to appropriate length, underwater joint processing can

    consult pump cable processing method. For more detailed mounting method please refer to the “water level

    sensor installation guide” chapters.

  • 8/18/2019 DC Pump Manual

    13/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 12 -

    e) Strap the connected cables of sensor and water pump on the pipeline at regular distance intervals。

    f) Hold up the pump and pipeline and pull them slowly into the well through the hoisting cable, when the pump

    to the appropriate height, please fix the hoisting cable to the manhole cover or the corresponding fixing

    device.

    g) Connect the ground water supply pipeline with pump outlet pipeline. This pump installation is complete, thenext step for the electrical installation and debugging.

    Warning

      The steel wire rope tensile strength must meet the actual demand, or pump has falling damage!

      Underwater wire water-proof treatment must be reliable, or it may cause water level judgment

    errors and machine burn out.

      Can’t use water pump connecting cables or pipe to lift pump, or it may cause: water pump fall

    well, machine damage and unpredictable accidents.

      The steel wire rope fixing device must be safe, reliable, or pump has falling damage risk!

    6.4 Electrical installation guide

    6.4.1 cable selection table:

    TypeDC input wire

    (mm2)

    Cables for pump

    (mm2)

    Water level detection

    wire(mm2)

    SPC-200 ≥2 1.5 0.5-1.0

    SPC-300 ≥2 1.5 0.5-1.0

    SPC-1000 ≥2 2 0.5-1.0

    SPC-1500 ≥2 1.5 0.5-1.0

    SPC-2200   ≥2 1.5 0.5-1.0

    SPC-3000   ≥2 1.5 0.5-1.0

    6.4.2 Terminal diagram:

    SPC series controller terminal diagram as shown in Fig 6.7, please correspond to actual models for electrical

    connection:

    Fig6.7 terminal diagram

    6.4.3 Wiring diagram:

    SPC series controller without charge function type wiring diagram as shown in Fig 6.8:

  • 8/18/2019 DC Pump Manual

    14/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 13 -

    Fig6.8 without charging function type wiring diagram

    SPC series controller with charging function type wiring diagram as shown in Fig6.9   ;

    Fig6.9 with charging function type wiring diagram

    6.4.4 water level sensor installation guide:

    a) Controller can pick up 2 channel water level sensor, that the source (well, rivers, lakes and so on) water level

    and water-filled water level sensor. Source water level sensor used to test whether water source is dry, prevent

    pump anhydrous idling and damage. Water-filled water level sensor used to check the high cistern or water

    tower is full filled with water or not, prevent water overflow waste. Source water level sensor is suggested to

    install, or motor would be damaged! Water-filled water level sensor according to the actual situation to decide

    whether or not to install.

    b) Water level sensor has a variety of specifications ,this handbook lists only floating ball type and probe type

    water level sensor. Note: The well diameter less than 8 inches cannot use float ball type sensor, must use the

    probe-type sensor.

    c) Source water level sensor installation: a, the float sensor installation as shown in Fig 6.10 , the float sensor

    suitable for wide surface water, diameter less than 60 CM wells can not be applied. B, the probe type sensor

    wiring way (Fig 6.11).

    Note: Dry water protection water level should be higher than the water outlet of the water pump, and the

    before restart to work, please assure the water capacity is enough for pump to work at least for 5 minutes.

  • 8/18/2019 DC Pump Manual

    15/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 14 -

    Fig6.10 floats sensor wiring mode in water source

    Fig 6.11 probe type sensor wiring mode in water source

    d) Water-filled sensor installation:

    Float sensor wring mode as shown in Fig6.12.

    Fig6.12 Float sensor wiring mode

    6.4.5 under water terminal guidance:

    a) Ordinary water and rive water usually have a low impedance electrical conductivity, and the cables of water

    pump and sensors are too short to meet the actual demand, so when the cable joints immersed in water, wire

    connection is needed to do waterproof treatment to avoid electric leakage accidents.

    b) Connection method : Let the cable head and pump outlet line respectively pass through the junction box

    waterproof connector and skinless butt, remark the U V W 3-phase logo in docking waterproof cables ,do

    insulation treatment with electrical tape and waterproof tape , then thread finishing into the junction box,

  • 8/18/2019 DC Pump Manual

    16/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 15 -

    and the waterproof box interior space filled with waterproof silicone as attached Fig6.13 shows.

    c) Sensor cable connection reference:motor lead line and cable connections

    Fig6.13 Motor lead wire and cable connection diagram

    6.4.6 The wiring matters needing attention:

    a) Please follow cable selection table recommended cable diameter. Other standard cable models please

    conversion or query the corresponding cable parameters table, and the prerequisite for effective conductive

    load area is not less than the recommended value. All the reference data in the table is based on the effective

    conductive cross-sectional area unit.

    b) The wire connecting controller and pump can not be connected to the capacitor or surge absorbers, otherwise

    it will cause the system often protected or even damage.

  • 8/18/2019 DC Pump Manual

    17/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 16 -

    Danger

      Note the positive and negative electrode must be connected correct, or may cause personal

    injury or equipment damage!

      Attention battery pole can not be short-circuited; otherwise it may cause injury or

    unpredictable accidents!

      Don't touch the machine terminals and cables after electrify, or get an electric shock risk!

    Warning

      Electric motor input lines (U V W) and controller terminal (U V W) must be connected correctly,

    otherwise the motor would turn in opposite direction, and the pump would not pump water.

      Attention the solar panel and battery connected to controller terminal under power, terminal

    would make sparks. Suggested that connect the solar panel and battery to the controller

    terminal after getting across the air switch.

    7. Operation Declaration

    7.1 Switch operation

    SPC series of photovoltaic water pump and controller with intelligent, automatic unattended and other characteristics,

    in the confirmation of all the machinery installation and electrical installation is correct, safe, accurate, only need to

    open the controller terminal at the top of the power switch can be automatically run.

    7.2 Display information:

    SPC series of photovoltaic water pump controller display panel as shown in Fig 7.1, for the function of indication

    information please see the indicator information table:

    Fig7.1 SPC series of photovoltaic water pump controller display panel

  • 8/18/2019 DC Pump Manual

    18/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 17 -

    Indicator information table

    name color Definition of indicator light

    POWER Green Power indicator

    RUN green Running indicator

    MPPT green MPPT indicator

    ERROR red Error indicator

    TANK FULL red Tank full indicator

    SOURCE LOW red Water low (water dry) indicator

    Danger

      Before boot, check the wiring connection terminal is correct, whether there is loose, confirmed

    no abnormal then to start, or may lead to unpredictable accidents.

    Warning

      Don’t switch air switch to control the start-stop of the water pump, or my cause damage to air

    switch or controller!

      Don’t let the water pump frequent start and stop, or easily cause damage to pump or controller.

    8. Working conditions

      Work environment temperature range:-10 — 50℃

      Environmental humidity:Less than 95%RH,no water condensation

      Vibration:Less than 5.9m/S2

    (0.6g)

      The storage temperature:-20 — 60℃

      Reduce the outlet power when altitude > 1000 meters.

    9. Maintenance

    In order to ensure the reliable operation of the system and prolong the service life, need regular comprehensive

    maintenance to pump and controller. Each year do at least one time preventive examination, include:

    Boot sound and the voltage and current are abnormal, starting device is working Properly, the controller set up

    multiple protections is normal movement, the main cable and control cable without aging crack, main contactor is

    stuck oxidation or burr, insulation resistance against ground is too low, whether the balance of three-phase winding

    resistance, stator and rotor are sweep chamber or scratches, controller water level sensor is normal or not reliable,

    floating ball movement is reliable, bearing has no wear, impeller has no wear or abrasion cavitations, the shaft is rust

    deformation or abrasion, motor internal and external fastening screws are loose, the pump inlet and the pump body

    around without sedimentation or clogging.

  • 8/18/2019 DC Pump Manual

    19/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 18 -

    10.Trouble shooting

    No Malfunction phenomena reason solution

    1Pump can’t operate and

    controller led off 

    Wrong connection of solar panel

    wires

    Switch off the controller, use multi-meter to read the

    voltage of S and N end of controller, if the reading to

    close to the open voltage of solar panel, the connection

    is right, otherwise, reconnect according to the manual.

    No sunshine or not enough

    Controll er switch off Set controller switch “on”

    2

    Controller power Led on,

    Run Led on, MPPT Led

    flicking, several seconds

    later, ERROR Led flick, then

    repeat those above

    reaction.

    3-phase UVW connects not well or

    cables is broken.

    Switch off the controller, use the multi-meter to read

    the resistance of any two ends of UVVW, if the

    connection is right, the resistance < 1Ω;otherwise, the

    resistance is infinite;e.g.:the resistance of UV ends

    is less

  • 8/18/2019 DC Pump Manual

    20/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

    - 19 -

    The Warranty agreement

    1.   Offer a three year warranty from the date of purchase.

    2.  Such as the following phenomenon in warranty period, will charge repair cost   :

      Due to transportation, use or improper keeping( such as liquid inlet, external forces, falls) resulted in the

    damage to the machine;

      Without accreditation from our company to repair, modification and maintenance resulted in machine

    damage;

      Due to natural disasters (such as: lightning, earthquake, fire, flood and so on) and disasters resulted in damage

    to the machine;

      Not according to the manual to operate and maintenance resulted in machine damage;

      Due to the fault of outside machine ( external equipment factors) resulted in damage;

      Warranty card and purchase invoices, both incomplete procedures

      Wearing parts (such as pump head, oil seal) and accessories not covered under warranty, if there is damage,

    need to purchase.

    3.  Product failure or damage, please fill out the “warranty card” in a correct and detailed way.

    4.  “Product warranty cards”, in general no replacement, please keep this card.

    5.  Warranty expires, in order to supply a lasting service to you, we will charge a repair cost.

    6.  Repair charges, will be in accordance with the latest “repair list”.

    7.   If there are questions in service process, please contact our company or our agents.

    8.  The right of final interpretation owe to our company.

      ted: Please pr vide y ur purchase v uchers bef re repairing。In rder t facilitate

    y ur cust dy, please affix the purchase v uchers in the space bel w.

      oduct wa anty ca d

    Product name

    Type/number

    Origin

    Date of

    purchase

    Repair time

    Fault

    condition

    Repair

    results

  • 8/18/2019 DC Pump Manual

    21/21

    SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.

      oduct wa anty ca d eceipt

    Customer

    nameTell

    Address Zip code

    Type Number

    Date of

    purchase

    Purchase

    origin

    Fault

    condition

    Repair

    results

    Degree of

    satisfaction

    Customer

    feedback