SPC Operating and Maintenance Instruction
SHENWU
Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
:1.1
-
8/18/2019 DC Pump Manual
2/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 1 -
Introduction
Thanks your purchase the SPC series of PV solar water pumps!
This instruction introduces the right installation and usage of SPC products. Please
read the instruction carefully before installation, application, maintenance and inspection.
Cautions
Upon opening please confirm :① water pump control system model, motor model is
consistent with your order.② the product certificate, user manual and warranty and
other accessories are complete.③ If there is any breakage phenomenon, if found to be
damaged, missing or damage, please contact with the company or your supplier to
solve.
The differences between explanatory pictures and real products do caused by the great
varieties of SPC series pump.
Because the product upgrades and specification upgrades, as well as to improve the
accuracy, the instruction will be updated in a timely manner, please note the current
version is the latest version before reading.
If you have any query after reading this instruction, please contact our customer service.
Customer service Tel:+86 132 0371 5884
-
8/18/2019 DC Pump Manual
3/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 2 -
SPC Operating and Maintenance Instruction
Contents
1. Security Information ----------------------------------------------------------- 3
2. Brief Description ---------------------------------------------------------------- 6
3. Product Introduction ----------------------------------------------------------- 6
4. Type Instruction ---------------------------------------------------------------- 7
5. SPC controller parameter ----------------------------------------------------- 7
6. Machine & Electricity installation ------------------------------------------- 8
7. Operation Declaration --------------------------------------------------------- 16
8. Working Conditions ------------------------------------------------------------- 17
9. Maintenance --------------------------------------------------------------------- 17
10.Trouble shooting ---------------------------------------------------------------- 18
Warranty Agreement---------------------------------------------------------------- 19
-
8/18/2019 DC Pump Manual
4/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 3 -
1. Security Information
Security Definition:There are two kinds of security attentions in this instruction:
Danger:The danger caused by the wrong operation on one’s own, may lead to heavy hurt or death.
Warning:The danger may result in moderate hurt or minor injury, and equipment’s damage.
Before you install, adjust and maintenance this system, please read this chapter carefully, and please bring your
attentions to the safety rules in this chapter. Our company has nothing to do with any damage caused by violations.
1.1 Before installation:
Danger
Please don’t install when unpacking found controller waterlogged, components or parts damaged!
Please don’t install when the real goods don’t conform to the specifications in PL!
Please handle the equipment gently, protect the equipment from damage.
Please don’t install or use when system control box installed components have defects or
deformation of the abnormal situation!
Please don’t touch controller components by hands, or there is electrostatic damage risk!
1.2 Installation:
Danger
Please install controller indoors, or rain, moisture proof outdoor mounting bracket (or
installation covering)!
Controller installation area should away from combustible materials, or may cause a fire!
Installing the controller fixed supports or mounting screws must be solid, otherwise the device
my fall and lead to dangerous incidents!
Submersible pump installation should be install lifting rope for lift hole, does not allowed pump
motor cable pulling, or the cables may be pull apart, pump falls and other unpredictable danger!
Warning
Can’t let the wire head, screws and other conductive objects fall into the controller; otherwise
it may cause damage to the controller.
Please install the control in the place with less shake and avoid direct sunlight.
Please note the installation location to ensure the cooling effect.
Please note the submersible depth of pump should no less than 0.5 meters, or may cause the
pump burned out!
1.3 Wiring:
-
8/18/2019 DC Pump Manual
5/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 4 -
Danger
Please carefully read the manual, and by professional electrical engineer operate, or may cause
a danger!
Before connection, please confirm the controller is without power, or may cause electric shock risk.
Please follow the manual figure and description to connect wires , otherwise may cause safety
accident!
Pay attention to the cross-sectional area of power supply line and water pump connecting cable
can meet the real needs, or may cause safety accident!
Please according to the standard operate the controller in a right way; otherwise there is a risk
of electric shock!
Never be the input power is connected to the output terminals (U,V,W), take notice of the
terminals mark, don’t pick the wrong line, or may cause a controller damage!
Note the DC input line (+), (-) polarity can not be reversed, or to cause the machine to burned or
more serious accidents!
If the pump cable joints under water, please make sure that the underwater joint waterproof
treatment is safe and reliable, otherwise it may result in damage to the equipment or more
serious safety accidents!
Ensure the distribution lines tally with the EMC requirements and local safety standard. The wire
size please refer to the manual’s proposal, otherwise may occur safety accident!
Warning
Electric motor input lines (U V W) must be connected correctly, otherwise the motor run in
opposite direction. And the pump would not pump water.
Note the high or low position of water level sensor, to set right gap control, avoid frequent reboot.
1.4 Before power on:
Danger
Ensure the input voltage in the rated voltage range of controller, otherwise may cause damage
to the machine or more serious consequences!
Please confirm all terminals connected firmly, without loosing and fastening won’t cause big
contract resistance, otherwise may cause the dangerous risk!
Please don’t use wet hands to touch the wires, terminals, switches, controllers, or may result in
damage to the equipment or cause unpredictable consequences!
Warning
Please confirm the output (U V W) wiring position is correct, otherwise the motor run reversely
or other accidents!
Check the external wiring whether has a short-circuit phenomenon, or may cause the controller
is damaged!
Don’t need to make any pressure test on any part of controller,or may lead to the accident!
Submerge the pump into the water for 15-20 minutes before first use. No dry runs. Or may cause
the pump burned out!
1.5 After power on:
-
8/18/2019 DC Pump Manual
6/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 5 -
Danger
Don’t use hands to touch controller wiring terminals, cables and etc, or there is a risk of electric
shock!
If the parameters need to be measured, please confirm and check whether the safety measures
is normal. Please attention any part of the body can not touch the charged terminal metal part,
otherwise may cause an electric shock risk!
If need to test and adjust machine, please note that the pump is completely immersed in the
water and well fixed, or may lead to unpredictable accidents!
Don’t collate or pull cables after power on, or may cause dangerous risk!
Warning
Don’t frequently switch controller, or it may cause damage to the machine!
1.6 In operation:
Danger
Amateur technicians can not detect signal in operation, or it may cause personnel injury or
equipment damage!
Please do not touch to test the temperature of the equipment, or may cause burns or other
accidents!
Warning
Avoid something or debris falls into the device, or it may cause damage to equipment or other
unpredictable accidents!
Don’t take the contactor (air switch on-off method) to control the start-stop of device, or easily
damage the switch!
Please note the intermittent start-stop time should not be less than 2 minutes, or may cause
damage to the machine!
1.7 Maintenance:
Danger
Don’t repair and maintenance the charged equipment, or there is a risk of electric shock!
In equipment downtime and shut off external power supply after 2 minutes to make the
maintenance and repair, or the residual charge on capacitor may cause harm to human body!
Non-professionally trained technician can not repair or maintenance the controller, or may cause
personal injury or equipment damage!
2. Brief Description
-
8/18/2019 DC Pump Manual
7/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 6 -
PV water pumping system is mainly composed of: solar water pump controller, pump, solar array and corresponding
connecting pipelines and cables, as shown in Fig2.1. Mainly used for lifting water, lakes, rivers and other water sources,
and used for agricultural irrigation, aquaculture, city greening, living water supply, water conservancy project. PV
water pumping system highlights its advantages in those areas where rich in solar energy resources but lack of city
electricity supply. Our company produces the SPC series DC photovoltaic pump system having the advantages of
environmental protection, high efficiency, unattended, and maintenance-free characteristics, which is an ideal green
environmental protection product.
Fig2.1 schematic diagram of PV water pumping system
3. Product Introduction
The SPC series PV pump system consists of: solar water pump controller, DC motor, solar array and corresponding
connecting pipelines and cables. This series product has the following advantages:
The DC PM brushless motor increases the efficiency up to 25% in comparison with traditional AC motor.
Adopt stator and rotor double plastic patented technology to do plastic insulation waterproofing treatment.
Motor insulation degree is larger than 300M ohm; greatly enhance the safety and reliability of motor.
The water lubricated bearing, relative to conventional bearings, has the advantages of easy installation, no
environmental pollution.
The microprocessor controller has advantages of MPPT, double water level detection control; prevent dry play
protection, automatic operation (unattended), etc.
SPC series solar water pump controller can be driven by solar array or battery. Customers can choose to purchase
controller with charging function, and join the battery to compose a system working 24 hours. The company can tailor
the PV pump system based on the actual needs the user.
4. Type Instruction
-
8/18/2019 DC Pump Manual
8/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 7 -
Controller Type
Pump Type:
5. SPC controller parameter
SPC controller size:
Mode
Dimensions
(mm)Hole Position (mm)
Hole
Dia(mm)Volume
size(mm)
L W A B C DSPC-200 218 174 125 94 200.5 Ø6 218*174*109
SPC-300 218 174 125 94 200.5 Ø6 218*174*109
SPC-1000 218 174 125 94 200.5 Ø6 218*174*109
SPC-1500 288 174 125 94 270.5 Ø6 288*174*109
SPC-2200 288 174 125 94 270.5 Ø6 288*174*109
SPC-2800 288 174 125 94 270.5 Ø6 288*174*109
SPC-4200 288 174 125 94 270.5 Ø6 288*174*109
SPC controller electrical parameter
SPC-200
Rated power 200W
Solahero Pump Controller
Voltage
Max flow rate
Solahero Pump
SHP-0.7/30-24
Max head
-
8/18/2019 DC Pump Manual
9/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 8 -
ModelRated power
(W)
Operation
Voltage(V)
Work voltage
range (V)
Max input
voltage(V)
Max power
current (A)
Net weight
(kg)
Gross weight
(kg)
SPC-200 200 24V 18-30V 36V 8A 1.51 1.95
SPC-300 300 36V 32-40V 45V 9A 1.51 1.95
SPC-1000 1000 48V 46-56V 65V 15A 1.53 1.97
SPC-1500 1500 110V 105-120V 180V 11A 2 2.44
SPC-2200 2200 280V 270-300V 380V 6A 2.05 2.49
SPC-3000 3000 290V 280-310V 380V 8A 2.05 2.49
SPC-4200 4200 300V 290-320V 380V 11A 2.05 2.49
Warning:
The total Voc voltage of solar module should not exceed the maximum input voltage of the
selected controller, or may cause damage.
The total Vmp voltage of solar module should be in working voltage range of motor, or may cause
the machine damaged.
6. Machine and Electricity Installation
6.1 solar module installations
6.1.1 solar panel selection:
Solar panel recommended configuration table
parameter SPC-200 SPC-300 SPC-1000 SPC-1500 SPC-2200 SPC-2800 SPC-4200
Maximum power(W) 210W 300W 200W 195W 270W 300W 240W
Maximum power voltage 27.6V 38.16V 26.48V 36.75V 36.1V 35V 34.56V
Open circuit voltage(Voc) 33V 44.64V 32.7V 45.4V 43.6V 41.3V 42.48
Maximum power current 7.6A 7.87A 7.45A 5.31A 7.48A 8.58A 6.96A
Required total quantity 1PCS 1PCS 4PCS 6PCS 8PCS 9PCS 18PCS
Power of solar array(W) 210W 300W 800W 1170W 2160W 2700W 4320W
6.1.2 solar panel installation:
Small power solar panel to
recommend the use of column type
solar bracket as shown in Fig 6.1:
-
8/18/2019 DC Pump Manual
10/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 9 -
Fig6.1 Column type solar bracket
Multiple solar panel to recommend the use of array type solar mounting as shown in Fig6.2:
Fig6.2 array type solar bracket
Solar array direction and elevation adjustments as shown in Fig6.3,first to adjust the light receiving horizontal area
face the direction of the sun at noon, then let the sun light (at noon) perpendicular to the light receiving area.
Fig6.3
The scientific method is: according to the actual local latitude and checking longitude, by checking table and actual
geographical situation calculate the horizontal installation direction and elevation, then install based on those
parameters.
warning
Unreasonable direction and elevation will reduce solar energy utilization ratio, thereby reduce
the efficiency of the system.
The elevation should change with the seasons and adjustment, especially in the high latitude
region should adjust the elevation angel to achieve the maximum solar utilization ratio.
6.2 SPC series controller installation
6.2.1 Installation environment:
a) Environment temperature :The temperature has great influence on service life, do not allow it exceeds the
allowed temperature range(-10℃— 50℃).
Morning
Noon
Evening
Solar panel
Solar panel
Elevation
Vertical sun
Noon
Horizontal plant
-
8/18/2019 DC Pump Manual
11/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 10 -
b) Vertically mounted controller, where there is enough space for cooling.
c) Install in the place with less vibration,Vibration should be less than 0.6G.
d) Avoid direct sunlight, humidity and water.
e) Avoid the corrosive, inflammable, explosive gases in air。
f) Don’t install in the grease and dusty place.
6.2.2 Controller installation:
Mount the controller on the column bracket as shown in Fig6.4, on the wall, electric control boxes and other flat
surface as shown in Fig6.5.
Fig6.4 controller mounted on the column type bracke
-
8/18/2019 DC Pump Manual
12/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 11 -
Fig 6.5 Controller mounted on wall and electric control box
6.3 pump installation
6.3.1 Pump installation steps:
a) Prepare sufficient long hoisting cable according to the actual situation and let it go through the water pump
hoisting hole and fixed by chunk (as shown in Fig6.6). Another end of hoisting cable is fixed to the derrick reel
or fixing device.
Fig6.6 hoisting cable installation
b) According to the actual situation prepare long enough waterproof 3 core cable( cable specifications with
reference to cable selection guide chapter),Let the cable head and pump lead line respectively pass through
the waterproof connector of water proof junction box and dock. And remark the U V W 3-phase identification
on docked waterproof cable. For more details please see under water connection guidance chapter.
c) Prepare a suitable water pipes to meet real needs( note the nominal pressure of the water pipes and pipe
fittings should be greater than the actual working pressure).Wind the outside wire connector with plastic
stripe then screw it into the outlet of water pump and connect.
d) Extend the cables of probe-type sensor or float sensor to appropriate length, underwater joint processing can
consult pump cable processing method. For more detailed mounting method please refer to the “water level
sensor installation guide” chapters.
-
8/18/2019 DC Pump Manual
13/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 12 -
e) Strap the connected cables of sensor and water pump on the pipeline at regular distance intervals。
f) Hold up the pump and pipeline and pull them slowly into the well through the hoisting cable, when the pump
to the appropriate height, please fix the hoisting cable to the manhole cover or the corresponding fixing
device.
g) Connect the ground water supply pipeline with pump outlet pipeline. This pump installation is complete, thenext step for the electrical installation and debugging.
Warning
The steel wire rope tensile strength must meet the actual demand, or pump has falling damage!
Underwater wire water-proof treatment must be reliable, or it may cause water level judgment
errors and machine burn out.
Can’t use water pump connecting cables or pipe to lift pump, or it may cause: water pump fall
well, machine damage and unpredictable accidents.
The steel wire rope fixing device must be safe, reliable, or pump has falling damage risk!
6.4 Electrical installation guide
6.4.1 cable selection table:
TypeDC input wire
(mm2)
Cables for pump
(mm2)
Water level detection
wire(mm2)
SPC-200 ≥2 1.5 0.5-1.0
SPC-300 ≥2 1.5 0.5-1.0
SPC-1000 ≥2 2 0.5-1.0
SPC-1500 ≥2 1.5 0.5-1.0
SPC-2200 ≥2 1.5 0.5-1.0
SPC-3000 ≥2 1.5 0.5-1.0
6.4.2 Terminal diagram:
SPC series controller terminal diagram as shown in Fig 6.7, please correspond to actual models for electrical
connection:
Fig6.7 terminal diagram
6.4.3 Wiring diagram:
SPC series controller without charge function type wiring diagram as shown in Fig 6.8:
-
8/18/2019 DC Pump Manual
14/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 13 -
Fig6.8 without charging function type wiring diagram
SPC series controller with charging function type wiring diagram as shown in Fig6.9 ;
Fig6.9 with charging function type wiring diagram
6.4.4 water level sensor installation guide:
a) Controller can pick up 2 channel water level sensor, that the source (well, rivers, lakes and so on) water level
and water-filled water level sensor. Source water level sensor used to test whether water source is dry, prevent
pump anhydrous idling and damage. Water-filled water level sensor used to check the high cistern or water
tower is full filled with water or not, prevent water overflow waste. Source water level sensor is suggested to
install, or motor would be damaged! Water-filled water level sensor according to the actual situation to decide
whether or not to install.
b) Water level sensor has a variety of specifications ,this handbook lists only floating ball type and probe type
water level sensor. Note: The well diameter less than 8 inches cannot use float ball type sensor, must use the
probe-type sensor.
c) Source water level sensor installation: a, the float sensor installation as shown in Fig 6.10 , the float sensor
suitable for wide surface water, diameter less than 60 CM wells can not be applied. B, the probe type sensor
wiring way (Fig 6.11).
Note: Dry water protection water level should be higher than the water outlet of the water pump, and the
before restart to work, please assure the water capacity is enough for pump to work at least for 5 minutes.
-
8/18/2019 DC Pump Manual
15/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 14 -
Fig6.10 floats sensor wiring mode in water source
Fig 6.11 probe type sensor wiring mode in water source
d) Water-filled sensor installation:
Float sensor wring mode as shown in Fig6.12.
Fig6.12 Float sensor wiring mode
6.4.5 under water terminal guidance:
a) Ordinary water and rive water usually have a low impedance electrical conductivity, and the cables of water
pump and sensors are too short to meet the actual demand, so when the cable joints immersed in water, wire
connection is needed to do waterproof treatment to avoid electric leakage accidents.
b) Connection method : Let the cable head and pump outlet line respectively pass through the junction box
waterproof connector and skinless butt, remark the U V W 3-phase logo in docking waterproof cables ,do
insulation treatment with electrical tape and waterproof tape , then thread finishing into the junction box,
-
8/18/2019 DC Pump Manual
16/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 15 -
and the waterproof box interior space filled with waterproof silicone as attached Fig6.13 shows.
c) Sensor cable connection reference:motor lead line and cable connections
Fig6.13 Motor lead wire and cable connection diagram
6.4.6 The wiring matters needing attention:
a) Please follow cable selection table recommended cable diameter. Other standard cable models please
conversion or query the corresponding cable parameters table, and the prerequisite for effective conductive
load area is not less than the recommended value. All the reference data in the table is based on the effective
conductive cross-sectional area unit.
b) The wire connecting controller and pump can not be connected to the capacitor or surge absorbers, otherwise
it will cause the system often protected or even damage.
-
8/18/2019 DC Pump Manual
17/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 16 -
Danger
Note the positive and negative electrode must be connected correct, or may cause personal
injury or equipment damage!
Attention battery pole can not be short-circuited; otherwise it may cause injury or
unpredictable accidents!
Don't touch the machine terminals and cables after electrify, or get an electric shock risk!
Warning
Electric motor input lines (U V W) and controller terminal (U V W) must be connected correctly,
otherwise the motor would turn in opposite direction, and the pump would not pump water.
Attention the solar panel and battery connected to controller terminal under power, terminal
would make sparks. Suggested that connect the solar panel and battery to the controller
terminal after getting across the air switch.
7. Operation Declaration
7.1 Switch operation
SPC series of photovoltaic water pump and controller with intelligent, automatic unattended and other characteristics,
in the confirmation of all the machinery installation and electrical installation is correct, safe, accurate, only need to
open the controller terminal at the top of the power switch can be automatically run.
7.2 Display information:
SPC series of photovoltaic water pump controller display panel as shown in Fig 7.1, for the function of indication
information please see the indicator information table:
Fig7.1 SPC series of photovoltaic water pump controller display panel
-
8/18/2019 DC Pump Manual
18/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 17 -
Indicator information table
name color Definition of indicator light
POWER Green Power indicator
RUN green Running indicator
MPPT green MPPT indicator
ERROR red Error indicator
TANK FULL red Tank full indicator
SOURCE LOW red Water low (water dry) indicator
Danger
Before boot, check the wiring connection terminal is correct, whether there is loose, confirmed
no abnormal then to start, or may lead to unpredictable accidents.
Warning
Don’t switch air switch to control the start-stop of the water pump, or my cause damage to air
switch or controller!
Don’t let the water pump frequent start and stop, or easily cause damage to pump or controller.
8. Working conditions
Work environment temperature range:-10 — 50℃
Environmental humidity:Less than 95%RH,no water condensation
Vibration:Less than 5.9m/S2
(0.6g)
The storage temperature:-20 — 60℃
Reduce the outlet power when altitude > 1000 meters.
9. Maintenance
In order to ensure the reliable operation of the system and prolong the service life, need regular comprehensive
maintenance to pump and controller. Each year do at least one time preventive examination, include:
Boot sound and the voltage and current are abnormal, starting device is working Properly, the controller set up
multiple protections is normal movement, the main cable and control cable without aging crack, main contactor is
stuck oxidation or burr, insulation resistance against ground is too low, whether the balance of three-phase winding
resistance, stator and rotor are sweep chamber or scratches, controller water level sensor is normal or not reliable,
floating ball movement is reliable, bearing has no wear, impeller has no wear or abrasion cavitations, the shaft is rust
deformation or abrasion, motor internal and external fastening screws are loose, the pump inlet and the pump body
around without sedimentation or clogging.
-
8/18/2019 DC Pump Manual
19/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 18 -
10.Trouble shooting
No Malfunction phenomena reason solution
1Pump can’t operate and
controller led off
Wrong connection of solar panel
wires
Switch off the controller, use multi-meter to read the
voltage of S and N end of controller, if the reading to
close to the open voltage of solar panel, the connection
is right, otherwise, reconnect according to the manual.
No sunshine or not enough
Controll er switch off Set controller switch “on”
2
Controller power Led on,
Run Led on, MPPT Led
flicking, several seconds
later, ERROR Led flick, then
repeat those above
reaction.
3-phase UVW connects not well or
cables is broken.
Switch off the controller, use the multi-meter to read
the resistance of any two ends of UVVW, if the
connection is right, the resistance < 1Ω;otherwise, the
resistance is infinite;e.g.:the resistance of UV ends
is less
-
8/18/2019 DC Pump Manual
20/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
- 19 -
The Warranty agreement
1. Offer a three year warranty from the date of purchase.
2. Such as the following phenomenon in warranty period, will charge repair cost :
Due to transportation, use or improper keeping( such as liquid inlet, external forces, falls) resulted in the
damage to the machine;
Without accreditation from our company to repair, modification and maintenance resulted in machine
damage;
Due to natural disasters (such as: lightning, earthquake, fire, flood and so on) and disasters resulted in damage
to the machine;
Not according to the manual to operate and maintenance resulted in machine damage;
Due to the fault of outside machine ( external equipment factors) resulted in damage;
Warranty card and purchase invoices, both incomplete procedures
;
Wearing parts (such as pump head, oil seal) and accessories not covered under warranty, if there is damage,
need to purchase.
3. Product failure or damage, please fill out the “warranty card” in a correct and detailed way.
4. “Product warranty cards”, in general no replacement, please keep this card.
5. Warranty expires, in order to supply a lasting service to you, we will charge a repair cost.
6. Repair charges, will be in accordance with the latest “repair list”.
7. If there are questions in service process, please contact our company or our agents.
8. The right of final interpretation owe to our company.
ted: Please pr vide y ur purchase v uchers bef re repairing。In rder t facilitate
y ur cust dy, please affix the purchase v uchers in the space bel w.
oduct wa anty ca d
Product name
Type/number
Origin
Date of
purchase
Repair time
Fault
condition
Repair
results
-
8/18/2019 DC Pump Manual
21/21
SPC Operating and Maintenance Instruction Zhengzhou Shenwu Electromechanical Industry Co., Ltd.
oduct wa anty ca d eceipt
Customer
nameTell
Address Zip code
Type Number
Date of
purchase
Purchase
origin
Fault
condition
Repair
results
Degree of
satisfaction
Customer