Page 1: DDA, DDC, DDE - WES Dosing  · PDF fileGRUNDFOS DATA BOOKLET SMART Digital DDA, DDC, DDE DIGITAL DOSING pumps and accessories

GRUNDFOS DATA BOOKLET

SMART DigitalDDA, DDC, DDE

DIGITAL DOSINGpumps and accessories

Page 2: DDA, DDC, DDE - WES Dosing  · PDF fileGRUNDFOS DATA BOOKLET SMART Digital DDA, DDC, DDE DIGITAL DOSING pumps and accessories

Func

tions

SMART Digital 3

Wiring diagram, DDA

Cable 1: Analog, external stop and pulse input

Cable 2: Level input

Cable 3: Genibus, analog output

Cable 4: Relay output

TM04

112

1 01

10; T

M04

155

2 12

10

21

34

21

345

23

4121

3►

2 1

GND

GNDBUS BUS

GND

12

3 4

12

3 4

125

3 4

34

1 2

Cable 1Analog/external stop/pulseProduct No.2 m cable: 966090145 m cable: 96609016

Cable 2Level inputsee page 38, suction lines

Cable 3Genibus, analog outputProduct No.2 m cable: 966329215 m cable: 96632922

Cable 4Relay outputProduct No.2 m cable: 966090175 m cable: 96609019

FlowControl input

Sensor

FunctionPin holes

Plug type1/brown 2/white 3/blue 4/black

Analog GND/ (-) mA (+) mA mA signalExternal stop GND X ContactPulse GND X Contact

FunctionPin holes

Plug type1 2 3 4

Low level X GND ContactEmpty tank X GND Contact

FunctionPin holes

Plug type1/brown 2/white 3/blue 4/black 5/yellow-green

Genibus +30 V GENI bus TXD GENI bus RXD GND BusAnalog output (+) mA GND/ (-) mA mA signal

FunctionPin holes

Plug type1/brown 2/white 3/blue 4/black

Relay 1 X X ContactRelay 2 X X Contact

19

Page 3: DDA, DDC, DDE - WES Dosing  · PDF fileGRUNDFOS DATA BOOKLET SMART Digital DDA, DDC, DDE DIGITAL DOSING pumps and accessories

Functions

20

SMART Digital3

Wiring diagram, DDC

Cable 1: Analog, external stop and pulse input

Cable 2: Level input

Cable 4: Relay output*

* applies to DDC-AR control variant

TM04

153

1 10

10

21

34

►GND

12

3 4

34

1 2

23

41

1 2

12

3 4

21

3GND

Cable 1Analog/external stop/pulseProduct No.2 m cable: 966090145 m cable: 96609016

Cable 2Level inputsee page 38, suction lines

Cable 4Relay outputProduct No.2 m cable: 966090175 m cable: 96609019

FunctionPin holes

Plug type1/brown 2/white 3/blue 4/black

Analog* GND/ (-) mA (+) mA mA signalExternal stop GND X ContactPulse GND X Contact

FunctionPin holes

Plug type1 2 3 4

Low level X GND ContactEmpty tank X GND Contact

FunctionPin holes

Plug type1/brown 2/white 3/blue 4/black

Relay 1 X X ContactRelay 2 X X Contact

Page 4: DDA, DDC, DDE - WES Dosing  · PDF fileGRUNDFOS DATA BOOKLET SMART Digital DDA, DDC, DDE DIGITAL DOSING pumps and accessories

Func

tions

SMART Digital 3

Wiring diagram, DDE-P

Cable 1: External stop and pulse input*

Cable 2: Level input*

* applies to DDE-P control variant

TM04

153

2 10

10

34

1 2

12

3 4

13

4

►GND

2 3GND

Cable 2Level inputsee page 38, suction lines

Cable 1External stop/pulseProduct No.2 m cable: 966090145 m cable: 96609016

FunctionPin holes

Plug type1/brown 2/white 3/blue 4/black

External stop GND X ContactPulse GND X Contact

FunctionPin holes

Plug type1 2 3 4

Empty tank X GND Contact

21

Page 5: DDA, DDC, DDE - WES Dosing  · PDF fileGRUNDFOS DATA BOOKLET SMART Digital DDA, DDC, DDE DIGITAL DOSING pumps and accessories

Acc

esso

ries

SMART Digital 8

Cables and plugsCables and plugs are used for the connection of the dosing pump to external control devices, such as process controllers, flow meters, level control units, etc. • Cable material: PVC, 0.34 mm2

• Plug type: M 12Fig. 25 Cable and plug

Technical data

TM04

826

7 04

11

Socket Application Pins Plug type Cable length [m] Product number

InputAnalogPulse

External stop4

Straight2 966090145 96609016

No cable 96698715Angled 2 96695976

Input Low levelEmpty tank 4 Straight No cable 96698715

Output AnalogGenibus 5

Straight2 966329215 96632922

No cable 96609031Angled 2 96699697

Output Relay 1Relay 2 4

Straight2 966090175 96609019

No cable 96696198Angled 2 96698716

35

Page 6: DDA, DDC, DDE - WES Dosing  · PDF fileGRUNDFOS DATA BOOKLET SMART Digital DDA, DDC, DDE DIGITAL DOSING pumps and accessories

Further product documentation

56

SMART Digital10

10. Further product documentation

WebCAPSWebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com.WebCAPS contains detailed information on more than 185 000 Grundfos products in more than 20 languages.In WebCAPS, all information is divided into 6 sections:• Catalogue• Literature• Service• Sizing• Replacement• CAD drawings.

Catalogue

With a starting point in areas of applications and pump types, this section contains • technical data• curves (QH, Eta, P1, P2, etc) which can be adapted to the

density and viscosity of the pumped liquid and show the number of pumps in operation

• product photos• dimensional drawings• wiring diagrams• quotation texts, etc.

Literature

In this section you can access all the lastest documents of a given pump, such as• data booklets• Installation and operating instructions• service documentation, such as Service kit catalogue and

Service kit instructions• quick guides• product brochures, etc.

Service

This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and cancelled Grundfos pumps.Furthermore, this section contains service videos showing you how to replace service parts.

Page 7: DDA, DDC, DDE - WES Dosing  · PDF fileGRUNDFOS DATA BOOKLET SMART Digital DDA, DDC, DDE DIGITAL DOSING pumps and accessories

Furt

her

prod

uct d

ocum

enta

tion

SMART Digital 10

WinCAPS

Fig. 62 WinCAPS CD-ROM

WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed informtion on more than 185,000 Grundfos products in more than 22 languages.The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available.WinCAPS is available on CD-ROM and updated once a year.

Sizing

With a starting point in different application areas and installation examples, this section gives easy step-by-step instructions in how to• select the most suitable and efficient pump for your installation• carry out advanced calculations based on energy

consumption, payback periods, load profiles, lifecycle costs, etc.

• analyse your selected pump via the built-in lifecycle cost tool• determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to select and compare replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. After having specified the installed pump, the guide suggests a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps.

The following formats are available in WebCAPS:

2-dimensional drawings• .dxf, wireframe drawings• .dwg, wireframe drawings.

3-dimensional drawings• .dwg, wireframe drawings (without surfaces)• .stp, solid drawings (with surfaces)• .eprt, E-drawings.

0 1

57