Page 1: Definite Purpose Contactors - GE Industrialapps.geindustrial.com/publibrary/checkout/DET-833...1Factory assembled DP starters (CR554 series) are available. Please refer to the Control

GE Industrial Solutions

Definite Purpose Contactors25-40 FLA Standard

Page 2: Definite Purpose Contactors - GE Industrialapps.geindustrial.com/publibrary/checkout/DET-833...1Factory assembled DP starters (CR554 series) are available. Please refer to the Control

2

OverviewGE's full complement of definite purpose contactors (20A-150A) are utilized in a variety of industrial electric equipment. These include heating, ventilating, air conditioning, refrigeration, food processing and agricultural, in addition to numerous other applications. The new feature rich 25-40A, 3-pole version has the great performance you have come to expect from GE. All definite purpose components by GE meet industry standards including ARI780, UL, CSA and CE.

Features

• 25A, 30A, 40A FLA rated, 2, 3 & 4 Poles• Optimal performance with double E magnet assembly• Visual on/off status indication• Variety of terminal choices allows diverse applications• Universal mounting plates and DIN-rail options make change outs simple• Snap-on accessories make modifications quick and easy• Starters are available with Class 10 and Class 20 overloads• Two-speed controllers incorporate a compact, integrated interlock

Page 3: Definite Purpose Contactors - GE Industrialapps.geindustrial.com/publibrary/checkout/DET-833...1Factory assembled DP starters (CR554 series) are available. Please refer to the Control

3

Ordering Information - DP Contactor

10987

C R 5 5 3 A

11 12 13 14 15 16

Ampere Rating

B 25AC 30AD 40A

Load Terminal2

A Binding Screw w/QCB Lug w/ Slotted Screw w/QCC Binding ScrewD Lug with Slotted Screw L Sems Clamp w/QC1

M Sems Clamp1

N Lug w/ Hex Head Screw P Lug w/ Hex Head Screw w/QC

1Not available in 40 FLA2 To mount overload relay on contactor load terminal: - Select option "M", Sems Clamp for 25/30amp - Select option "D", Lug with Slotted Screw for 40amp

Number of Poles

2 2 Poles3 3 Poles4 4 Poles

Contactor Coil Voltage

A110-120V 60Hz110V 50Hz

B208-240V 60Hz220V 50Hz

C440-480V 60Hz380-415V 50Hz

D575-600V 60Hz550V 50Hz

E 12V 50/60 HzF 277V 60HzH 24V 50/60Hz

Line Terminal

A Binding Screw w/QCB Lug w/ Slotted Screw w/QCC Binding ScrewD Lug with Slotted ScrewL Sems Clamp w/QC1

M Sems Clamp1

N Lug w/ Hex Head Screw P Lug w/ Hex Head Screw w/QC

10

11

7

8

9

Auxiliary Contacts Left Right Front

A – – – –B 250 V 1 SPDT – –C 250 V – 1 SPDT –D 250 V 2 SPDT – –E 250 V – 2 SPDT –F 250 V 1 SPDT 1 SPDT –G 250 V 2 SPDT 2 SPDT –H 600 V 1 NO-NC – –J 600 V – 1 NO-NC –K 600 V 1 NO-NC 1 NO-NC –L 600 V 2 NO – –M 600 V – 2 NO –N 600 V 2 NO 2 NO –P 600 V 1 NO-NC 2 NO –Q 600 V 2 NO 1 NO-NC –R 600 V – – 1 NOS 600 V – – 1 NCT 600 V – – 1 NO-NC

12

Modification

0 None1 Coil Rotated with Coil Terminals Down3 DIN Rail Mounting Provision4 Coil Rotated with Coil Terminals Down and DIN Rail Mounting Provision5 Dummy Quick Connect Tabs on Coil6 Coil Rotated with Coil Terminals Down and Dummy Quick Connect Tabs

on Coil8 Dummy Quick Connect Tabs on Coil and DIN Rail Mounting Provision9 Coil Rotated with Coil Terminals Down and DIN Rail Mounting Provision

and Dummy Quick Connect Tabs on Coil

13

Special Marking

A None* Customer Specific options assigned by Factory

Terminal Marking

A Standard Terminal MarkingB Inverse Terminal MarkingC Reverse Terminal MarkingD Without Terminal Marking

Packaging

A Single PackP Bulk Pack – Minimum order quantity 96 pieces with multiples of 8 pieces

Ordering Bulk Packs? Just add A0AAP to the Standard Product Number.

Complete Product Numbers:

11 digits for Standard

16 digits for Customized

Omit digit 12 through 16, if the selection is “A0AAA”

16

15

14

Select options in 7 through 11 for Standard Configurations Add Options 12 through 16 for Customized Configurations

Page 4: Definite Purpose Contactors - GE Industrialapps.geindustrial.com/publibrary/checkout/DET-833...1Factory assembled DP starters (CR554 series) are available. Please refer to the Control

4

DP Contactors Standard Product Numbers

FLAAmps

Coil Voltage TerminalsProduct No.

2 PoleProduct No.

3 PoleProduct No.

4 Pole

25A

24VACBinding Screw with QC CR553AB2HAA CR553AB3HAA CR553AB4HAA

Lug w/Slotted Screw w/QC CR553AB2HBB CR553AB3HBB CR553AB4HBB

110-120VACBinding Screw with QC CR553AB2AAA CR553AB3AAA CR553AB4AAA

Lug w/Slotted Screw w/QC CR553AB2ABB CR553AB3ABB CR553AB4ABB

208 - 240VBinding Screw with QC CR553AB2BAA CR553AB3BAA CR553AB4BAA

Lug w/Slotted Screw w/QC CR553AB2BBB CR553AB3BBB CR553AB4BBB

277VBinding Screw with QC CR553AB2FAA CR553AB3FAA CR553AB4FAA

Lug w/Slotted Screw w/QC CR553AB2FBB CR553AB3FBB CR553AB4FBB

FLAAmps

Coil Voltage TerminalsProduct No.

2 PoleProduct No.

3 PoleProduct No.

4 Pole

30A

24VACBinding Screw with QC CR553AC2HAA CR553AC3HAA CR553AC4HAA

Lug w/Slotted Screw w/QC CR553AC2HBB CR553AC3HBB CR553AC4HBB

110-120VACBinding Screw with QC CR553AC2AAA CR553AC3AAA CR553AC4AAA

Lug w/Slotted Screw w/QC CR553AC2ABB CR553AC3ABB CR553AC4ABB

208 - 240VBinding Screw with QC CR553AC2BAA CR553AC3BAA CR553AC4BAA

Lug w/Slotted Screw w/QC CR553AC2BBB CR553AC3BBB CR553AC4BBB

277VBinding Screw with QC CR553AC2FAA CR553AC3FAA CR553AC4FAA

Lug w/Slotted Screw w/QC CR553AC2FBB CR553AC3FBB CR553AC4FBB

FLAAmps

Coil Voltage TerminalsProduct No.

2 PoleProduct No.

3 PoleProduct No.

4 Pole

40A

24VACBinding Screw with QC CR553AD2HAA CR553AD3HAA CR553AD4HAA

Lug w/Slotted Screw w/QC CR553AD2HBB CR553AD3HBB CR553AD4HBB

110-120VACBinding Screw with QC CR553AD2AAA CR553AD3AAA CR553AD4AAA

Lug w/Slotted Screw w/QC CR553AD2ABB CR553AD3ABB CR553AD4ABB

208 - 240VBinding Screw with QC CR553AD2BAA CR553AD3BAA CR553AD4BAA

Lug w/Slotted Screw w/QC CR553AD2BBB CR553AD3BBB CR553AD4BBB

277VBinding Screw with QC CR553AD2FAA CR553AD3FAA CR553AD4FAA

Lug w/Slotted Screw w/QC CR553AD2FBB CR553AD3FBB CR553AD4FBB

25A 30A 40A

Page 5: Definite Purpose Contactors - GE Industrialapps.geindustrial.com/publibrary/checkout/DET-833...1Factory assembled DP starters (CR554 series) are available. Please refer to the Control

5

Technical Data• Ambient Operating Temperature: -25° C to 40° C

• Power Terminal

– Pressure Type: 16-8 AWG, Torque: 20 in-lbs

– Lug Type: 14-4 AWG, Torque: 40 in-lbs

• Coil Terminal

– Pressure Type: 18-12 AWG, Torque: 10 in-lbs

• #6-32 Screws and Double 0.250 Quick Connect Terminals

• Coil is rated Class B (130° C ) Insulation System

Standards and Listings• UL60947-4-1a, UL File E1811

• RoHS / REACH certified

Contact DataFLA, A

Resistiveamp per pole

Voltage, V LRA, ASingle

Phase (hp)Three Phase

(hp)

25 35

120240480600

150150125100

23--

-7.51010

30 40

120240480600

180180150120

25--

-101515

40 50

120240480600

240240200160

37.5

--

-102020

Nominal Coil voltage VAC Frequency FLA Poles 12 24 110-120 208-240 277 440-480 550-600

Maximum pickup voltageDrop-out voltage range

60Hz25 / 30 / 40A25 / 30 / 40A

2, 3 & 42, 3 & 4

9.64.2

186 - 15

8820 - 70

17750 - 165

22065 - 185

352150 - 270

440192 - 336

Nominal inrush VA

60Hz25 / 30 A

40 A25 / 30 / 40A

2, 334

44100100

44100100

44100100

44100100

44100100

44100100

44100100

50Hz25 / 30 A

40 A25 / 30 / 40A

2, 334

53120120

53120120

53120120

53120120

–––

53120120

53120120

Nominal sealed VA

60Hz25 / 30 A

40 A25 / 30 / 40A

2, 334

5.69.59.5

5.69.59.5

5.69.59.5

5.69.59.5

5.69.59.5

5.69.59.5

5.69.59.5

50Hz25 / 30 A

40 A25 / 30 / 40A

2, 334

6.811.411.4

6.811.411.4

6.811.411.4

6.811.411.4

–––

6.811.411.4

6.811.411.4

Coil Data

C US

25A with Overload Relay

Page 6: Definite Purpose Contactors - GE Industrialapps.geindustrial.com/publibrary/checkout/DET-833...1Factory assembled DP starters (CR554 series) are available. Please refer to the Control

6

Accessories – Auxiliary Contact Kits

Enclosure Kits NEMA Type 1

Type Mounting Circuit Product Number Rating

250 VAC Auxiliary Contact

Side 1 SPDT CR553XC211 11 A, 1/3 HP at 250 VAC;1/2 A at 125 VDC;1/4 A at 250 VDCSide 2 SPDT CR553XC222

600 VAC Auxiliary Contact

Front 1 NO BCLF10

A600, Q600 Pilot DutyFront 1 NC BCLF01

Side 1 NO, 1 NC BCLL11

Side 2 NO BCLL20

Mechanical Interlock2 - 2 NCBEL02 includes 2 built-in NC contacts

A600, Q600 Pilot Duty

2Factory assembled DP 2-speed contactors (CR555 series) are available. Please refer to the Control catalog, GEP-1260 for more information.

Contactor Prefix Device Rating Product Number

CR553A DP Contactors 25A-40A, 2-4 Pole CR553XE1A

CR554A DP Starters 25A-30A CR553XE1A

CR554A DP Starters 40A CR553XE1B

Spare Coils

Coil Voltage

Product Number

2/3 Pole 25-30FLA

2/3 Pole 40FLA4 Pole 25-40FLA

110-120V 50/60Hz CRDB1AA CRDB3AA

208-240V 50/60Hz CRDB1AB CRDB3AB

440-480V 60HzCRDB1AC CRDB3AC

380-415V 50Hz

550-600V 50/60Hz CRDB1AD CRDB3AD

12V 50/60Hz CRDB1AE CRDB3AE

277V 60Hz CRDB1AF CRDB3AF

24V 50/60Hz CRDB1AH CRDB3AH

Class 10 - Overload Class 20 - OverloadCurrentRange

MaximumFuse

Maximum CircuitBreaker Rating Amps

ProductNumber

0.16-0.26 1 15 RT1B

0.25-0.41 1 15 RT1C

0.4-0.65 3 15 RT1D

0.65-1.1 6 15 RT1F

1-1.5 6 15 RT1G

1.3-1.9 6 15 RT1H

1.8-2.7 10 15 RT1J

2.5-4.1 15 15 RT1K

4-6.3 20 15 RT1L

5.5-8.5 25 15 RT1M

8.0-12.0 40 30 RT1N

10.0-16.0 50 35 RT1P

14.5-18 60 40 RT1S

17.5-22 70 50 RT1T

21-26 80 60 RT1U

25-32 100 80 RT1V

30-40 100 80 RT1W1Factory assembled DP starters (CR554 series) are available. Please refer to the Control catalog, GEP-1260 for more information.

CurrentRange

MaximumFuse

Maximum CircuitBreaker Rating Amps

ProductNumber

2.5-4.1 15 15 RT12K

4-6.3 20 15 RT12L

5.5-8.5 25 15 RT12M

8.0-12.0 40 30 RT12N

10.0-16.0 50 35 RT12P

14.5-18 60 40 RT12S

17.5-22 70 50 RT12T

21-26 80 60 RT12U

25-32 100 80 RT12V

30-40 100 80 RT12W

Overload Relay

Accessories - Overload1

250V Auxiliary Contact Kits

Side-Mount 600V Auxiliary Contact Block

Front-Mount 600V Auxiliary Contact Block

Mechanical Interlock Enclosure Kit

Page 7: Definite Purpose Contactors - GE Industrialapps.geindustrial.com/publibrary/checkout/DET-833...1Factory assembled DP starters (CR554 series) are available. Please refer to the Control

7

Outline Drawings Approximate Dimensions in (mm)

Mounting Dimensions

THE

INFO

RMAT

ION

CO

NTA

INED

IN T

HIS

DO

CUM

ENT

IS G

EPC

PRO

PRIE

TRY

INFO

RMAT

ION

AN

D IS

DIS

CLO

SED

IN C

ON

FID

ENCE

. IT

IS T

HE

PRO

PERT

YO

F G

EPC

AND

SH

ALL

NO

T BE

USE

D, R

EPRO

DU

CED

OR

DIS

CLO

SED

TO

OTH

ERS

IN W

HO

LE O

R IN

PAR

TW

ITH

OU

T TH

E EX

PRES

S PE

RMIS

SIO

N O

F G

EPC.

LA IN

FORM

ACIO

N C

ON

TEN

IDA

EN E

STE

DO

CUM

ENTO

ES

INFO

RMAC

ION

PRIV

ADA

DE

GEP

C Y

ES E

STRI

CTAM

ENTE

CO

NFI

DEN

CIAL

.ES

PRO

PIED

AD D

E G

EPC

Y N

O P

OD

RA S

ER U

SAD

A, R

EPRO

DU

CID

A O

EXPU

ESTA

A T

ERCE

ROS

EN S

U T

OTA

LID

A O

EN

PAR

TE S

IN L

AEX

PRES

A AU

TORI

ZACI

ON

ESC

RITA

DE

GEP

C

GEP

C2ST

DA3

- Re

v. 0

3 - 0

7-O

ct-2

010

TERE

S_45

0100

27XX

_00_

00-

--

-O

BJEC

T FI

LE N

AME:

SYS:

eEng

:D

P253

P_SC

KETC

HRE

VISI

ON

VERS

ION

:ST

ATU

S:D

RAW

ING

FIL

E N

AME:

DRA

WIN

G R

ELAT

ED IN

FORM

ATIO

N

V = mm3

DRAWING

BRANCH: -

MODELBRA

NCH: -

- - Ver. 1 / FIRST EDITION 10-Nov-14 S.Rivadeneira - -

- - - - - - - - -

mm1:1

-A3 1 1

DP253P_SCKETCH-

- - - - --

-Part must conform to SI 900000 Section 4 Toxicity Procedure. -Article or Material Must Conform to RoHS Procedure SI900000 Sec. 13 -Article or Material Must Conform to REACH Procedure SI900000 Sec. 14

- -

1.65 (41.3)

.34 (8.5)

3.25 (82.6)

3.13 (79.4)

UL 60947-4-1 // IEC/EN 60947-4-1

Pressure Type: #8-16AWG 20lb-in/2.2 N-m

LUG Type: #4-14AWG 40lb-in/4.5 N-m

Coil Screw: #12-18AWG 10lb-in/1.1 N-m

Cu 75° C wire only

Herm. Refrig. Comp. 50/60Hz

Break All Lines RES PER POLE: 35A

Ui=1000V Ue=400/690V

AC-8a 25A @ 600V

*For Control Volts and Hz, see Coil

SUITABLE FOR USE ON A CIRCUIT CAPABLEOF DELIVERING NOT MORE THAN 5000RMS SYM AMPS, 600 VOLTS MAX.Made in Poland

VAC120240480600

LRA150150125100

FLA

25

IP-HP 2 3

3P-HP

7.5 10 10

CR553AB3*BBB

A

C

Approximate Dimensions - in (mm)

Aux Contact

Aux Contact

D D

AuxContact

E

THE

INFO

RMAT

ION

CO

NTA

INED

IN T

HIS

DO

CUM

ENT

IS G

EPC

PRO

PRIE

TRY

INFO

RMAT

ION

AN

D IS

DIS

CLO

SED

IN C

ON

FID

ENCE

. IT

IS T

HE

PRO

PERT

YO

F G

EPC

AND

SH

ALL

NO

T BE

USE

D, R

EPRO

DU

CED

OR

DIS

CLO

SED

TO

OTH

ERS

IN W

HO

LE O

R IN

PAR

TW

ITH

OU

T TH

E EX

PRES

S PE

RMIS

SIO

N O

F G

EPC.

LA IN

FORM

ACIO

N C

ON

TEN

IDA

EN E

STE

DO

CUM

ENTO

ES

INFO

RMAC

ION

PRIV

ADA

DE

GEP

C Y

ES E

STRI

CTAM

ENTE

CO

NFI

DEN

CIAL

.ES

PRO

PIED

AD D

E G

EPC

Y N

O P

OD

RA S

ER U

SAD

A, R

EPRO

DU

CID

A O

EXPU

ESTA

A T

ERCE

ROS

EN S

U T

OTA

LID

A O

EN

PAR

TE S

IN L

AEX

PRES

A AU

TORI

ZACI

ON

ESC

RITA

DE

GEP

C

GEP

C2ST

DA3

- Re

v. 0

3 - 0

7-O

ct-2

010

TERE

S_45

0100

27XX

_00_

00-

--

-O

BJEC

T FI

LE N

AME:

SYS:

eEng

:D

P253

P_SC

KETC

HRE

VISI

ON

VERS

ION

:ST

ATU

S:D

RAW

ING

FIL

E N

AME:

DRA

WIN

G R

ELAT

ED IN

FORM

ATIO

N

V = mm3

DRAWING

BRANCH: -

MODELBRA

NCH: -

- - Ver. 1 / FIRST EDITION 10-Nov-14 S.Rivadeneira - -

- - - - - - - - -

mm1:1

-A3 1 1

DP253P_SCKETCH-

- - - - --

-Part must conform to SI 900000 Section 4 Toxicity Procedure. -Article or Material Must Conform to RoHS Procedure SI900000 Sec. 13 -Article or Material Must Conform to REACH Procedure SI900000 Sec. 14

- -

1.65 (41.3)

.34 (8.5)

3.25 (82.6)

3.13 (79.4)

UL 60947-4-1 // IEC/EN 60947-4-1

Pressure Type: #8-16AWG 20lb-in/2.2 N-m

LUG Type: #4-14AWG 40lb-in/4.5 N-m

Coil Screw: #12-18AWG 10lb-in/1.1 N-m

Cu 75° C wire only

Herm. Refrig. Comp. 50/60Hz

Break All Lines RES PER POLE: 35A

Ui=1000V Ue=400/690V

AC-8a 25A @ 600V

*For Control Volts and Hz, see Coil

SUITABLE FOR USE ON A CIRCUIT CAPABLEOF DELIVERING NOT MORE THAN 5000RMS SYM AMPS, 600 VOLTS MAX.Made in Poland

VAC120240480600

LRA150150125100

FLA

25

IP-HP 2 3

3P-HP

7.5 10 10

CR553AB3*BBB

A

C

Approximate Dimensions - in (mm)

Aux Contact

Aux Contact

D D

AuxContact

E

Amp Poles A B CD

E250V 600V

25, 30Amp 2 , 3 2.07 (53) 3.75 (96) 3.50 (89) 0.55 (14) 0.28 (7) 1.1 (28)

40 Amp 2, 3 2.24 (57) 3.75 (96) 4.02 (102) 0.71 (18) 0.43 (11) 1.1 (28)

25 / 30 / 40Amp 4 2.24 (57) 4.00 (101) 4.02 (102) 0.71 (18) 0.43 (11) 1.1 (28)

Enclosure CR553XE1A

1.63

1.38

.504.63 1.131.00

[28.6][25.4]1.751.75

3.00[44.4] [44.4]

[76.2]

[117.5]

[34.9]

[12.7]

1.38[35.1]

.18[4.6]

[41.3]

8.00

10.00

1.00

[254.0]

[203.2]

[25.4]

6.00

3.00

[152.4]

[76.2]

1.004.00[25.4][101.6]

"A"BOTH SIDES

3 POINT MTG.FOR #10 SCREW

"A"

"B"(TOP & BOTTOM)

"A""B"

Combination Knockouts For 1/2 OR 3/4-inch ConduitCombination Knockouts For 3/4 or 1-Inch Conduit

"A"BACK

RESET BUTTON INSTARTER ENCLOSURE

(TOP & BOTTOM)

Enclosure CR553XE1A

Enclosure CR553XE1B

1.63

1.50

.506.13

1.501.19[38.1][30.2]

2.382.00

3.69[50.8] [60.3]

[93.7][155.6]

[38.1]

[12.7]

1.50[38.1]

.18[4.6]

[41.3]

11.00

13.25

1.13

[336.6]

[279.4]

[28.7]

7.38

3.69

[187.3]

[93.7]

1.19[30.2]

"A"BOTH SIDES

3 POINT MTG.FOR #10 SCREW

"B"

"A"(TOP & BOTTOM)

"A""B"

Combination Knockouts For 1/2 OR 3/4-inch ConduitCombination Knockouts For 3/4 or 1-Inch Conduit

"A"BACK

RESET BUTTON INSTARTER ENCLOSURE

(TOP & BOTTOM)

Enclosure CR553XE1B

5.00[127]

Page 8: Definite Purpose Contactors - GE Industrialapps.geindustrial.com/publibrary/checkout/DET-833...1Factory assembled DP starters (CR554 series) are available. Please refer to the Control

Information provided is subject to change without notice. Please verify all details with GE. All values aredesign or typical values when measured under laboratory conditions, and GE makes no warranty orguarantee, express or implied, that such performance will be obtained under end-use conditions.©2015, General Electric Company and/or its affiliates. All rights reserved.

8.15 DET-833C

GE Industrial Solutions 41 Woodford Avenue Plainville, CT 06062 1-800-431-7867 www.geindustrial.com

Refer to Control Catalog GEP-1260 for detailed DP contactors, assembled DP starters, 2-speed contactor versions.

Visit our Definite Purpose Contactor information page at www.geindustrial.com/products/contactors/definite-purpose-contactors