delta infrasuite cast resin busway system...2 delta cast resin busway system a flexible, safe, and...
TRANSCRIPT
www.deltapowersolutions.com
BL Series, 400A-6400AIP68
Delta InfraSuite Cast Resin Busway System
The power behind competitiveness
Delta GroupLeading expert in power management and thermal management solutions
No. 1 Supplier of Merchant Power SuppliesAccording to the IHS report, Delta Electronics remained the largest supplier of merchant power supplies with an estimated market share of 15.5% in 2016 of a global market value that was estimated to be $21,869 M.
Delta Group is the world’s leading provider of power management and thermal management solutions, as well as a major source for components, visual displays, industrial automation, networking products, and renewable energy solutions. Delta Group is focused on three main businesses: power electronics, energy management, and smart green life. Delta Group has sales offices worldwide and manufacturing plants in Taiwan, China, Thailand, Japan, Mexico, India, Brazil and Europe.
As a global leader in power electronics, Delta’s mission is, “To provide innovative, clean and energy-efficient solutions for a better tomorrow.” Delta is committed to environmental protection and has implemented green, lead-free production and recycling and waste management programs for many years.
More information about Delta Group can be found at http://www.deltaww.com/
Source : AC-DC & DC-DC Merchant Power Supplies, IHS, 2017
World no. 1 in Switching Power Supplies, DC Brushless Fans and Telecom Power Systems
163 sales offices and 39 manufacturing facilities worldwide
5%-6% of annual sales revenues invested in R&D with over 7,000 engineers in 64 R&D centers worldwide
Awarded 7,100+ patents and received 47 internationally recognized design awards including iF, Reddot, and the
Taiwan Excellence awards.
The Total Merchant Power Supply Market 2016 $M Revenue
Ranking Company Name Market Share
1 Delta Electronics 15.5%
2 Axxxxxn 7.5%
3 Lxxxxxx Technology 4.5 %
0201
Delta Group
No. 1 supplier of merchant power supplies
Leading expert in power management and thermal management solutions
Source: IHS report, AC-DC & DC-DC Merchant Power Supplies - 2016
Delta Group is the world’s leading provider of power management and thermal management solutions, as well as a major source for components, visual displays, industrial automation, networking products, and renewable energy solutions. Delta Group is focused on three main businesses: power electronics, energy management, and smart green life. Delta Group has sales offices worldwide and manufacturing plants in Taiwan, China, Thailand, Japan, Mexico, India, Brazil and Europe.
As a global leader in power electronics, Delta’s mission is, “To provide innovative, clean and energy-efficient solutions for a better tomorrow.” Delta is committed to environmental protection and has implemented green, lead-free production and recycling and waste management programs for many years.
More information about Delta Group can be found at http://www.deltaww.com/
According to the IHS report, Delta Electronics remained the largest supplier of merchant power supplies with an estimated market share of 17.5% in 2015 of a global market value that was estimated to be $19,732 M.
World no. 1 in Switching Power Supplies, DC Brushless Fans and Telecom Power Systems
153 sales offices and 38 manufacturing facilities worldwide
5%-6% of annual sales revenues invested in R&D with over 7,000 engineers in 61 R&D centers worldwide
Awarded 7,100+ patents and received 47 internationally recognized design awards including iF, Reddot,
and the Taiwan Excellence awards.
The Total Merchant Power Supply Market 2015 $M Revenue
Ranking
1 Delta Electronics 17.5%
2 Axxxxxn 9.5%
3 Lxxxxxx Technology 8.0%
Company Name 2015
Global footprint
Awards
Liptovsky HradokDubnica
Rudrapur
Beijing
Dongguan
Seoul
New Delhi
Bangalore
Singapore
Wuhu
Chenzhou
Wujiang
ShanghaiTaipei
TaoyuanHsinchu
Tainan
Chungli
Urumqi
MoscowEindhoven
IstanbulRome
Johannesburg
TeningenBern
GlasgowAmsterdam
Soest
Bangkok
Melbourne
Dubai
Detroit
Mexico City
Raleigh
Sydney
Bogota
Frankfurt
Cairo
Drammen
Lima
San Diego
San Francisco
DallasAustin
Curitiba
Bucharest
WarsawParis
NairobiLagos
Milano
Mumbai
Los Angeles
Tijuana
PortlandSeattle
Houston
Sao PauloSao Jose dos Campos
Madrid
St. Petersburg
Tokyo
Osaka
Morioka
Nagoya
Cordoba
Sales Offices
Plant Sites
R&D Centers
963243
37 153
2
2047 11 61
38
Asia-Pacific
Sales OfficesPlant SitesR&D Centers
Americas EMEA Total
2014CPLI Climate Performance
Leadership Index, CPLI
2009Frost & Sullivan GreenExcellence Award forCorporate Leadership
2011 - 2015Dow Jones
Sustainability Indexes
2007 - 2008Forbes Asia’sFabulous 50
Global Footprint
AwardsDelta Electronics outperformed 37 leading global companies in the Electronic Equipment, Instrument, and Component sector of the 2017 Dow Jones Sustainability Indexes (DJSI), and was selected for the DJSI World Index for the seventh consecutive year.
More information about Delta Group can be found at http://www.deltaww.com/
Sales Offices
Plant Sites
R&D Centers
104 (61)32 (19)43 (23)
39 163
3
2047 12 64
39
Asia-Pacific (China)
Sales OfficesPlant SitesR&D Centers
Americas EMEA Total
Detroit
Mexico City
Raleigh
Bogota
Lima
San Diego
San Francisco
DallasAustin
Curitiba
Los Angeles
Tijuana
PortlandSeattle
Houston
Sao PauloSao Jose dos Campos
Cordoba
Liptovsky HradokDubnica
Rudrapur
Beijing
Dongguan
Seoul
New Delhi
Bangalore
Singapore
WuhuChenzhou
Wujiang
ShanghaiTaipei
TaoyuanHsinchu
Tainan
Chungli
Urumqi
MoscowEindhoven
IstanbulRome
Johannesburg
TeningenBern
GlasgowAmsterdam
Soest
Bangkok
Melbourne
Dubai
Sydney
Frankfurt
Cairo
Drammen
Bucharest
WarsawParis
NairobiLagos
Milano
Mumbai
Madrid
St. Petersburg
Tokyo
Osaka
Morioka
Nagoya
1
Table of contents● Product Portfolio
● System Architecture
● Features & Advantages
● Safety
● Busway
● Joint
● Plug-in Unit
● Applications
● Technical Specifications
1
3
4
5
6
8
9
10
11 - 28
2
Delta Cast Resin Busway SystemA Flexible, Safe, and Reliable Low Voltage Power Distribution Solution
The Busway BL Series from Delta are made from epoxy using vacuum casting. Superior to traditional cables or sandwich type busway solutions, Delta’s Busways significantly improve the protection ratings, safety and reliability of products, are ideal for use in harsh environmental conditions, and can be extensively applied to a range of industries. Thanks to the outstanding electrical and mechanical properties of resin, these busways have reduced dimensions, a simplified structure, extended service life, and improved reusability. More importantly, Delta’s Busways provide excellent energy-savings to help our customers enjoy substantial savings on their electricity bills.
Delta’s Busways vs. Traditional CableDelta’s Busways excel over traditional cables in terms of safety, electrical properties, reliability, and scalability, making them the best choice for companies looking at optimum TCO.
Customer Value● Flexible modular design allows easy
disassembly, reconstruction, and expansion as well as high re-usability
● Excellent safety, as well as waterproof, dustproof, fireproof, shock-proof, and corrosion-proof
● Certified according to market-specific or customer-specific needs, such as by the IEC, CNS, GB, and others
● Highly compact
Cast Resin Busway system Normal Cable
System flexibility Easily detaching joints, replaceable, re-usable and highly adaptable to system design changes
Need re-wiring in case of system changes
Installation and configuration Quick installation and configuration Wiring over premises, costly and time-consuming
Space use efficiency Only 30% of traditional cable wiring, effective insaving installation space
Ducts in addition to wiring, bulky
Appearance Easy to identify and manage at a glance Messy power wiring, complicated looks
Fire resistance High, IEC60331 None
IP Rating IP68 Not specified in the general technical data
Resistance to chemical and corrosion
Excellent Poor
Instantaneous short-circuit strength
High Low
Overload capacity(+25% 2hr)
High Low in heat resistance (up to about 60℃), thus being dangerous when overloaded, leading to accelerated insulating materials aging and reduced service life
Insulation rating High, resin insulation Class F (155oC). Low
3
System Architecture
Feeder section
Flatwise elbow
Edgewise elbow
Flange end
Flange end/FST
Plug-in section (bolt-on type)
Plug-in slot (bolt-on type)
1
2
3
4
5
6
7
Plug-in unit (bolt-on type)
Plug-in section (plug-in type)
Plug-in slot (plug-in type)
Plug-in unit
Cable box/End feed box
Joint
Spring hanger
8
9
10
11
12
13
14
1
2
9 5
34
13
1011
12
86
7
14
4
Features and AdvantagesSafe, reliable, innovative, energy-saving
● Copper 600A ~ 6400A,Aluminum 400A ~ 5000A
● Rated voltage up to 1000V. ● Operating ambient temperature -20oC ~50oC, daily average up to 35oC
Altitude up to 2,000 meters. ● Model 3P3W or 3P4W, 50%G or 100%G.● IP68 at busway feeder section, IP54 at plug-in section● Modular design, easy disassembling and reassembling, and highly
expandable● Integrated cast resin block, with detachable bridge-type joints . ● Easy installation, effective foolproof design to prevent installation errors● Design and Standards IEC60439-2, IEC61439, IEC60529, IEC60331, IEC60332
JIS C8364, JIS A1304, JIS H3140 GB7251.1,GB7251.2, ANSI/UL857,NEMA BU-1
● Delta’s Cast Resin Busway system is only 60% of the size of traditional sandwich busways, and 30% of the size of traditional electrical cable wiring.
● The busway joint is constructed as moving connecting modules, easy to assemble, disassemble, expand, and reuse when changing layout.
● The plug-in unit works with MCCB from major manufacturers allowing live line operations at anytime to change loads without cutting off power and saving both time and money.
● Maintenance-free throughout its service life, reducing OPEX.
Normal busways have high power-consuming resistors in conductors, leading to expensive electricity bills. Delta’s Busway uses state-of-the-art technology to not only cut electricity costs, but also effectively reduce electromagnetic interference, preventing damage to precision equipment. ● CoAlly Technology: Conductors are set to the optimum low-resistance state to
reduce energy consumption as well as carbon footprints, while contributing to environmental protection and low power costs.
● SiShield Technology: With a low-impedance electrolytic copper plate, the conductor has optimum low resistance, effectively reducing loss and voltage drops. In addition, the internally coated composite significantly mitigates electromagnetic interference to protect precision equipment.
Key Specifications and Functions
Flexible and Cost-saving
Innovative Energy-saving Materials
5
Safety
Delta’s Cast Resin Busway system implements an integrated, formed design, with the conductors fully sealed in an epoxy composite during casting. Thanks to the outstanding binding and sealing properties of epoxy materials, the cast busways are highly waterproof.
Ideal for demanding weather conditions and rugged operating environments, such as:● Outdoors, pipe, AC plant rooms, and other spaces where condensate tends
to form● Locations with many fire-fighting hoses, water piping and chemical ducts● Resistant to salt corrosion, high humidity environment
Fire resistance: IEC60332IEC60331 750oC 3hrsCNS12514 840oC 30mins
Delta’s busways are certified as fire resistance with industrial IEC standard, and conform to the latest fire control regulations. In case of fire, the busways can ensure a continuous emergency power supply to prevent injuries and/or facility damage, and would play an important role in electrical safety.
Shock-proof: 0.8g
Shock-proof rating >0.4g = Magnitude 7. Shock-proof tests have been performed with simulated real-life building construction, including steel structures, horizontal busways, vertical busways, busway elbows, plug-in units, hangers, spring hangers and more, to ensure all components are resistant to shock.
Explosion-proof: ExmⅡ CNS3376/IEC60079
Ideal for use in a demanding environments with a risk of explosion, such as compressed natural gas filling stations, oil refineries, offshore platforms, wind farms, tunnels, mines, and others
Impact-proof: IK10
Waterproof, Dustproof
6
Busways
Copper and aluminum conductors are available. Copper conductors have electric conductivity of higher than 99.9%, while aluminum conductors have electric conductivity of higher than 56%. For optimum electric conductivity and contact reliability, both the copper and aluminum conductors are plated entirely with tin.
For the best possible electrical, mechanical, waterproof, fireproof and self-extinguishing properties, the resin materials and their whole set of formulas are sourced from the most experienced and renowned manufacturers. The insulation rating is Class F, with a temperature limit up to 155°C. The resin is made with a high proportion of inorganic materials, such as natural sands transformed and cured into ceramic materials, thus possessing excellent insulating capabilities, high mechanical strength and outstanding fireproof properties.
Delta’s Cast Resin Busways feature an integrated, formed design, with the conductors fully sealed in an epoxy composite during casting, with highlights that include:
Conductor Materials
Resin Materials
Busway Structure
● Waterproof
● Epoxy made with a high proportion of inorganic materials such as natural sand that possess excellent insulating capability, high mechanical strength and excellent fireproof properties
● Plug-in unit works with MCCB from major manufacturers allowing live line operations anytime to change loads, without cutting off power to save both time and money
● Maintenance-free throughout its service life, saving on operating costs
7
Code Digit 1st Code Digit 2nd Code Digit
Protected against contact with dangerous parts and foreign objects
Protected against water
0 No particular protection No particular protection1 I. Protecting back of the hand from getting in contact with
dangerous partsII. Protecting against solid objects greater than 50mm in diameter
Protecting against vertically falling water drops
2 I. Protected against finger contact with dangerous parts II. Protecting against solid objects greater than 12.5mm in diameter
Protecting against vertically falling water drops when enclosure is tilted up to 15°
3 I. Protecting against test stick greater than 2.5mm in diameter from getting in contact with dangerous partsII. Preventing contact with foreign objects greater than 2.5mm in diameter
Protecting against water sprayed at an angle of up to 60° degrees on either side of the enclosure
4 I. Protecting against test stick greater than 1.0mm in diameter from getting in contact with dangerous parts II. Protecting against solid objects greater than 1.0mm in diameter
Protecting against water splashed against enclosure from any direction
5 Dust protected, dust not allowed to interfere with safety of the product
Protecting against water splashed against enclosure from any direction for continuous 3 minutes
6 Dustproof, no ingress of dust Protecting against water injected against enclosure from any direction for continuous 3 minutes
7 Protecting against water when enclosure is immersed in water with the lowest point of the enclosure 1 m below the water surface , for 30 minutes
8 Protecting against water when enclosure is immersed in water with depth and duration expected to be greater than requirements for Class 7
Busway IP rating
Ingress Protection rating
Conforming to IEC60529, CNS14165 standards, higher rating is available under demand.
1
23
6
5
7
IP X X
Feeder section IP68
Plug-in section IP66Joint IP68
Joint expansion IP68
End box IP 54
Expansion unit
4 Plug-in unit IP42
8
Joint
● Connection between busways is achieved by linking conductors of two busways with a movable joint. With the easily detachable joint design, replacing busways when changing power system design or adding loops, can be done in a short time, minimizing downtime.
● With the double-bolt design, stress distribution over the copper plate contact surfaces at the joint is more extensive and uniform, ensuring more reliable binding for the two busways. This promises reliability even after long-term stress fluctuation due to thermal expansion.
● The busway uses a 4-piece movable packing at the joint. After the screws at the joint are screwed to the end with a required torque, and the indication tag falls, the cap is forced onto the busways following the sealing and screwing process. The solid silicone packing wrapping the busway joint and the cap will seal any seam to ensure IP68 waterproof reliability at the joint.
● The joint is designed with foolproof functions that only allow fixed-torque screws to be set when busways are correctly positioned. Not until the fixed-torque screws are screwed to the end and have the head falling, can the sealing plate be installed. This ensures every installation step of the busway joint is done properly.
9
Plug-in unit● With this plug-in unit design, when users want to add equipment or adjust power load, what they need to do is to get
parts meeting the specifications of the desired plug-in unit specifications and mount the plug-in unit to the proper and closest busway slot to guide out power, without cutting off the busway. This allows for quick and easy installation, and in turn great flexibility and convenience.
● Plug-in unit is provided in two versions, both allowing live line plug/unplug operations:
Plug-in type capacity: Up to 630A, with conductive clip design, suitable for light load systems.
Bolt-on type capacity: Up to 2000A, with a bolt bridge design, suitable for heavy load systems. Bolt packing ensures great reliability.
● The plug-in section busway has a standard length of 4.2m, with up to 5 reserved input ports. The number and location of input ports may be customized to customers’ needs, thereby saving costs and preventing unnecessary waste.
● The plug-in units are able to be customized with MCCB from any leading manufacturer and is highly adaptable to customers’ practical needs.
● The plug-in unit may be equipped with a monitoring module, allowing power information to be read on board or otherwise displayed, or transmitted to the monitoring system through RS485.
Plug-in unit with monitoring module Conductive clip design
(Plug-in Type)
Bolt bridge design (Bolt-on Type)
10
Applications
Emergency, outdoor appli-
cations
Petro-chemis-try, marine, oil
& gas
Critical equip-ment, datacen-
ters
Electronics, semiconductor
, wafer fabrication
Water treatment Wind farms
Waterproof, dustproof IP68
● ● ● ● ● ●
Fireproof and burning-proof
● ● ● ●
Explosion-proof ● ● ● ● ● ●
Resistance to chemical corrosion
● ● ● ● ● ●
Shock-proof ● ● ● ●
With the rapid growth of global IT industry, factories are built to increasingly large scales. This adds to the demand for quality power supply, safe power transfer and efficient systems, as well as greater expandability. As busway development has reached higher levels of reliability, safety and flexibility due to fast delivery and flexible engineering changes, busways are now used extensively in a variety of industries.
In addition to power transmission/distribution, Delta’s Busways also feature high protection ratings and are ideal for harsh environmental conditions and mission critical applications required high reliability and safety.
11
Technical Specifications
Busway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
ModelsCopper BLC06 BLC08 BLC10 BLC12 BLC16 BLC20 BLC25 BLC32 BLC40 BLC50 BLC64Aluminum BLA04 BLA06 BLA08 BLA10 BLA12 BLA15 BLA16 BLA20 BLA25 BLA32 BLA40 BLA50
Rated voltage V 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000Rated current A 400 600 800 1000 1250 1500 1600 2000 2500 3200 4000 5000 6400Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60Conductor Copper purity: 99.9% conductivity: 99.9%IACS
Aluminum purity: 98.0% conductivity: 56.0%IACS
Conductor plating Tin plating
Insulation material Epoxy Cast resin
Insulation class F class 155°C
Fire resistance IEC60331 750°C 3hrs; IEC60332
CNS12514 840°C 30mins(Special made-C)
Ingress protection rating IP68
Earthquake test 0.8g [magnitude >7]
Explosive-symbol ExmII
Mechanical Impact IK10
Color RAL7043
Plug-in unit
Type Plug-in type/Bolt-on type
Pole 1P/2P/3P/4P
Max.rating Plug-in type 630A
Bolt-on type 2000A
MCCB brands Mitsubishi, Fuji, GE, Schneider (MG), or Customer specified
Protection rating IP42/IP55 (Optional)
Panel coating Powder coated paint
Coating thickness Indoor 40μm/outdoor 50μm
Color RAL7047/RAL7043
GeneralStandards IEC60439-2,IEC61439,IEC60529,IEC60331,IEC60332
JIS C8364,JIS A1304,JIS H3140
GB7251.1,GB7251.2, ANSI/UL857,NEMA BU-1
Ambient temperature -20°C/+50°C avg.35°C
Altitude ≦ 2,000m
12
Temperature rise
0400800
1200160020002400280032003600400044004800520056006000640068007200
Ampe
res
K
Temperature rise-Copper
6400A
5000A
4000A
3200A
2500A
2000A
1600A
1250A
1000A
800A
600A
0 3 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
5000A
4000A
3200A
2500A
2000A
1600A
1250A
1000A800A
600A
400A
1500A
K
0 3 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 800
400800
1200160020002400280032003600400044004800520056006000640068007200
Ampe
res
Temperature rise-Aluminum
Temperature rise graph (Copper)
Temperature rise graph (Aluminum)
0400800
1200160020002400280032003600400044004800520056006000640068007200
Ampe
res
K
Temperature rise-Copper
6400A
5000A
4000A
3200A
2500A
2000A
1600A
1250A
1000A
800A
600A
0 3 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
5000A
4000A
3200A
2500A
2000A
1600A
1250A
1000A800A
600A
400A
1500A
K
0 3 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 800
400800
1200160020002400280032003600400044004800520056006000640068007200
Ampe
res
Temperature rise-Aluminum
13
Rating [A]RMS Symmetrical (kA)
6 cycles 1 sec 3 sec
600 140 65 38
800 140 65 38
1000 140 65 38
1250 140 65 38
1600 175 80 46
2000 175 80 46
2500 220 100 58
3200 280 130 75
4000 410 175 101
5000 410 200 115
6400 410 200 115
Rating [A]RMS Symmetrical (kA)
6 cycles 1 sec 3 sec
400 105 50 29
600 105 50 29
800 105 50 29
1000 140 65 38
1250 140 65 38
1500 140 65 38
1600 140 65 38
2000 175 80 46
2500 175 80 46
3200 220 100 58
4000 280 130 75
5000 410 175 101
Short-circuit strength
Copper
Aluminum
14
LH型彎頭Flatwise elbow
FH型盤接頭Flange end/flatwise elbow
NH型彎頭Flatwise offset
TH型彎頭Flatwise Tee
CH型彎頭Flat to edge elbow
盤接頭Flange end
LV型彎頭Edgewise elbow
NV型彎頭Edgewise offset
TV型彎頭Edgewise Tee
CV型彎頭Edge to flat elbow
FV型盤接頭Flange end/edgewise elbow
Busway elements
LH-type elbow LV-type elbow
NV-type elbow
TV-type elbow
CV-type elbow
FV-type flange end
FH-type flange end
TH-type elbow
CH-type elbow
NH-type elbowFlatwise offset
FS type flange endFlange end
15
末端接線箱End tap box
插入單元Plug-in unit
伸縮接頭Expansion fitting
末端封蓋End cover
五金另料 (固定元件)Ceiling trapeze
彈簧架Spring hanger
中間接線箱Center tap box
插入單元附電錶箱Plug-in unit /Power meter box
轉接頭 (大電流轉小電流)Unfused reducer
SE型末端槽體Feeder end
穿牆法蘭Wall/Floor flange
Busway elements
16
Properties
Figure 1
Figure 2
CopperBusway Ratings 600A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
Models BLC06 BLC08 BLC10 BLC12 BLC16 BLC20 BLC25 BLC32 BLC40 BLC50 BLC64Rated voltage V 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000Rated current A 600 800 1000 1250 1600 2000 2500 3200 4000 5000 6400Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60Impedance valuesFor busway operating at 50Hz frequency and 85oC temperatureResistance R20 μΩ/m 106.3 68.7 50.2 34.7 23.0 17.9 15.1 11.6 9.0 7.6 6.1
Resistance R85 μΩ/m 133.5 86 .2 63 .0 43.5 28.9 22.5 18.9 14.5 11.3 9.5 7.7
Reactance X50 μΩ/m 112.3 79.9 57.3 42.3 28.0 22.1 17.7 13.4 10.0 8.8 6.3
Impedance Z50 μΩ/m 174.5 117.5 85.2 60.7 40.2 31.5 25.9 19.7 15.1 12.9 9.9
For busway operating at 60Hz frequency and 85oC temperatureResistance R20 μΩ/m 106.3 68.7 50.2 34.7 23.0 17.9 15.1 11.6 9.0 7.6 6.1
Resistance R85 μΩ/m 133.5 86.2 63.0 43.5 28.9 22.5 18.9 14.5 11.3 9.5 7.7
Reactance X60 μΩ/m 134.8 95.9 68.8 50.8 33.6 26.5 21.2 16.1 12.0 10.6 7.6
Impedance Z60 μΩ/m 189.7 128.9 93.3 66.9 44.3 34.8 28.4 21.7 16.5 14.2 10.8
Conductor cross-sectionL1,L2,L3 mm2 145 232 307.4 464 696 928 1160 1392 1856 2320 2784N(100%) mm2 145 232 307.4 464 696 928 1160 1392 1856 2320 2784G(Internal) mm2 72.5 116 153.7 232 348 464 580 696 928 1160 1392Busway Dimensionh x w mm 100x55 100x70 100x83 100x110 100x150 100x190 100x230 100x270 100x395 100x475 100x555Joint A x B mm 152x93 152x93 152x106 152x133 152x173 152x213 152x253 152x293 152x418 152x498 152x578Figure 1 1 1 1 1 1 1 1 2 2 2
Voltage drop ΔU = √3 x I (R85 Cosφ + X50/60 Sinφ) (V/m)I : loading current Cosφ : power factor Sinφ = (1 - Cosφ ²)½
17
Properties
Figure 1
Figure 2
Figure 3
AluminumBusway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A
Models BLA04 BLA06 BLA08 BLA10 BLA12 BLA15 BLA16 BLA20 BLA25 BLA32 BLA40 BLA50Rated voltage V 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000Rated current A 400 600 800 1000 1250 1500 1600 2000 2500 3200 4000 5000Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60Impedance valuesFor busway operating at 50Hz frequency and 85oC temperatureResistance R20 μΩ/m 110.2 84.8 55.1 47.0 39.3 29.8 24.8 21.8 15.7 13.6 10.9 9.3
Resistance R85 μΩ/m 138.2 106 .3 69.1 58.9 49.3 37.4 31.1 27.4 19.7 17.1 13.7 11.6
Reactance X50 μΩ/m 128.0 76.5 56.9 49.8 38.6 28.9 22.3 17.4 12.9 10.0 8.3 5.8
Impedance Z50 μΩ/m 188.4 131.0 89.5 77.1 62.6 47.3 38.3 32.5 23.5 19.8 16.0 13.0
For busway operating at 60Hz frequency and 85oC temperatureResistance R20 μΩ/m 110.2 84.8 55.1 47.0 39.3 29.8 24.8 21.8 15.7 13.6 10.9 9.3
Resistance R85 μΩ/m 138.2 106 .3 69.1 58.9 49.3 37.4 31.1 27.4 19.7 17.1 13.7 11.6
Reactance X60 μΩ/m 153.6 91.8 68.3 59.8 46.3 34.7 26.8 20.9 15.5 12.0 9.9 7.0
Impedance Z60 μΩ/m 206.6 140.5 97.2 83.9 67.6 51.0 41.1 34.5 25.1 20.9 16.9 13.5
Conductor cross-sectionL1,L2,L3 mm2 232 307 .4 464 580 696 928 1160 1392 1856 2320 2784 3480N(100%) mm2 232 307 .4 464 580 696 928 1160 1392 1856 2320 2784 3480G(Internal) mm2 116 153.7 232 290 348 464 580 696 928 1160 1392 1740Busway Dimensionh x w mm 100x70 100x83 100x110 100x130 100x150 100x190 100x230 100x270 100x395 100x475 100x555 100x720Joint A x B mm 152x93 152x106 152x133 152x153 152x173 152x213 152x253 152x293 152x418 152x498 152x578 152X743Figure 1 1 1 1 1 1 1 1 2 2 2 3
Voltage drop ΔU = √3 x I (R85 Cosφ + X50/60 Sinφ) (V/m)I : loading current Cosφ : power factor Sinφ = (1 - Cosφ ²)½
18
Dimensions and Weight
Figure 1
Figure 2
Figure 3
CopperBusway Ratings 600A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
Models BLC06 BLC08 BLC10 BLC12 BLC16 BLC20 BLC25 BLC32 BLC40 BLC50 BLC64h x w mm 100x55 100x70 100x83 100x110 100x150 100x190 100x230 100x270 100x395 100x475 100x555Joint AxB mm 152x93 152x93 152x106 152x133 152x173 152x213 152x253 152x293 152x418 152x498 152x578Weight 3P3W 50% G Kg/m 13.9 18.9 23.3 32.4 45.8 59.3 72.7 86.1 118.6 145.4 172.2Weight 3P3W 100% G Kg/m 14.5 19.7 24.5 34.1 48.3 62.6 76.8 91.1 125.2 153.6 182.2Weight 3P4W 50% G Kg/m 15.0 20.6 25.5 35.7 50.8 65.9 81.0 96.0 131.8 162.0 192.0Weight 3P4W 100% G Kg/m 15.5 21.4 26.6 37.4 53.3 69.2 85.1 101.0 138.4 170.2 202.0Figure 1 1 1 1 1 1 1 1 2 2 2
AluminumBusway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A
Models BLA04 BLC06 BLC08 BLC10 BLC12 BLA15 BLA16 BLA20 BLA25 BLA32 BLA40 BLA50h x w mm 100x70 100x83 100x110 100x130 100x150 100x190 100x230 100x270 100x395 100x475 100x555 100x720Joint AxB mm 152x93 152x106 152x133 152x153 152x173 152x213 152x253 152x293 152x418 152x498 152x578 152x743Weight 3P3W 50% G Kg/m 14.0 16.6 22.2 26.4 30.6 39.0 47.3 55.6 78.0 94.6 111.2 141.9Weight 3P3W 100% G Kg/m 14.1 16.7 22.5 26.7 30.9 39.4 47.8 56.2 78.8 95.6 112.4 143.4Weight 3P4W 50% G Kg/m 14.2 16.9 22.6 26.9 31.2 39.8 48.3 56.8 79.6 96.6 113.6 144.9Weight 3P4W 100% G Kg/m 14.3 17.0 22.9 27.2 31.5 40.2 48.8 57.4 80.4 97.6 114.8 146.4Figure 1 1 1 1 1 1 1 1 2 2 2 3
19
Flange end
CL
CL
CL
CL
CL
CL
CL
CL
3P4W盤接頭法蘭開孔尺寸圖
3P3W盤接頭法蘭開孔尺寸圖
Figure 1 Figure 2 Figure 3 Figure 4
Figure 5 Figure 6
44.425
W 44.4
Ø14
N L3 L2 L1 G
(600A為Ø12)
W
44.425
Ø14
N L3 L2 L1 G
44.425
75.6
44.4
44.4
W
Ø14
N L3 L2 L1 G
44.425
44.4
44.4
W
44.4
44.4
45
N L3 L2 L1
Ø14
44.425
88.8
W
88.8
45
G
Ø14
44.425
75.6
44.4
44.4
W
75.6
44.4
44.4
45
N L3 L2 L1 G
Ø14
44.425
44.4
44.4
W
44.425
88.8W
Ø14
Ø14
N L3 L2 L1
G(600A is of Ø12)
Flange end opening dimension diagram
Flange end opening dimension diagram
CopperBusway Ratings 600A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
A mm 65 80 93 120 160 200 240 280 405 485 565B mm 105 120 133 160 200 240 280 320 445 525 605C mm 135 150 163 190 230 270 310 350 475 555 635D mm 150 190 230W mm 25 40 53 80 120 160 200 240 365 445 525Figure 1 1 1 2 2 3 3 4 5 5 6Weight Kg 10 14 16 22 30 39 46 52 71 87 100
※ For openings of busways with outdoor-type flange end on top, additional technical diagrams are required for compiling the opening dimensions
20
Flange end
CL CL
Figure 1 Figure 2 Figure 3 Figure 4
Figure 5 Figure 6
Figure 7
CL
CL
CL
CL
CL
3P3W盤接頭法蘭開孔尺寸圖
W
44.425
Ø14
N L3 L2 L1 G
44.425
44.4
44.4
W
44.425
88.8W
Ø14
Ø14
N L3 L2 L1 G(1600A)
G(1500A)
44.425
W 44.4
Ø14
N L3 L2 L1 G
44.425
75.6
44.4
44.4
W
Ø14
N L3 L2 L1 G
44.425
75.6
44.4
44.4
W
75.6
44.4
44.4
45
Ø14
N L3 L2 L1 G
44.425
44.4
44.4
W
44.4
44.4
45
Ø14
44.425
88.8
W
88.8
45
Ø14
G(2500A)N L3 L2 L1 G(3200A)
44.425
44.4
44.4
W
44.4
44.4
4545
44.4
44.4
Ø14
N L3 L2 L1 G
CL
CL
CL
CL
CL
3P4W盤接頭法蘭開孔尺寸圖
AluminumBusway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A
A mm 80 93 120 140 160 200 240 280 405 485 565 730B mm 120 133 160 180 200 240 280 320 445 525 605 1770C mm 150 163 190 210 230 270 310 350 475 555 635 800D mm 150 190 230 300W mm 40 53 80 100 120 160 200 240 365 445 525 690Figure 1 1 2 2 2 3 3 4 5 5 6 7Weight Kg 10 12 15 16 20 25 31 36 49 60 70 95
※ For openings of busways with outdoor-type flange end on top, additional technical diagrams are required for compiling the opening dimensions
Flange end opening dimension diagram
Flange end opening dimension diagram
21
Plug-in Type
3 3 φ 3W 100%G4 3 φ 3W 50%G5 3 φ 4W 100%G
7 3 φ 4W 0%G8 3 φ 4W 50%N 0%G9 3 φ 3W 0%G
10 3 φ4W 50%N 50%G
3 φ 4W 50%G
M MCCB MCCB type Serial number: 01~99
Plug-in opening
Plug-in opening /w cover
Plug-in unit
Plug-in unit(Plug-in type)
TerminalsTAmp. Ratings 10A~630A
1P
1Pole2Pole3Pole4Pole
11 3 φ4W 200%N 50%G
DimensionsPlug-in Amp. Ratings 30A 63A 100A 225A 250A 400A 630A
L mm 500 500 500 500 500 700 850L1 mm 250 250 250 250 250 350 350W mm 300 300 300 300 300 430 430H mm 275 275 275 275 275 305 335D mm 280 280 280 280 280 280 410IP Rating IP42 IP42 IP42 IP42 IP42 IP42 IP42Weight Kg 15 15 17 21 22 25 53
Note: A standard plug-in unit is rated IP42. For customers needing higher protection rating, IP55 is available on demand
Single side openings may have up to 5 input/output ports, while double sided openings as customized products may have up to 10 input/output ports
22
DimensionsPlug-in Amp. Ratings 63A 100A 225A 250A 400A 630A 800A 1000A 1200A 1600A 2000A
L mm 500 500 500 500 700 850 850 1100 1100 1100 1300W mm 300 300 300 300 300 430 430 430 530 530 530H mm 270 270 270 270 300 330 330 380 380 380 560D mm 280 280 280 280 280 410 410 410 510 510 510IP Rating IP42 IP42 IP42 IP42 IP42 IP42 IP42 IP42 IP42 IP42 IP42Weight Kg 17 19 23 24 27 55 58 65 70 80 80
Bolt-on Type
OFF ONTRIPO I
Plug-in opening
Plug-in opening /w cover
Plug-in unit
Plug-in unit(Bolt-on type)
NF1600SEW
MCCB type
1600
Amp. Ratings 63A~2000A M MCCBTerminalsT
BO
Serial number: 01~99
1P
1Pole2Pole3Pole4Pole
6
3 3 φ 3W 100%G4 3 φ 3W 50%G5 3 φ 4W 100%G
7 3 φ 4W 0%G8 3 φ 4W 50%N 0%G9 3 φ 3W 0%G
10 3 φ4W 50%N 50%G
3 φ 4W 50%G
11 3 φ4W 200%N 50%G
Note: A standard plug-in unit is rated IP42. For customers needing higher protection rating, IP55 is available on demand
23
Junction box
BL C EB6
C CuA Al
3 3φ3W 100%G4 3φ3W 50%G5 3φ4W 100%G6 3φ4W 50%G7 3φ4W 0%G8 3φ4W 50%N 0%G9 3φ3W 0%G
10 3φ4W 50%N 50%G
Dimension A08
72504 400A 20 2000A06 600A 25 2500A08 800A 32 3200A10 1000A 40 4000A12 1250A 50 5000A15 1500A 64 6400A
Figure 1 Figure 2 Figure 3
16 1600A
EB End tap box
※屋外型接線箱尺寸詳圖, 須另提供技術圖面以供套圖11 3 φ4W 200%N 50%G※For outdoor junction boxes, additional technical diagrams are required for compiling the dimensions
CopperBusway Ratings 600A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
W mm 205 220 233 260 300 340 380 420 545 625 705W1 mm 55 70 83 110 150 190 230 270 395 475 555IP Rating IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54Figure 1 1 1 1 1 1 1 1 2 2 2
AluminumBusway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A
W mm 220 233 260 280 300 340 380 420 545 625 705 875W1 mm 70 83 110 130 150 190 230 270 395 475 555 720IP Rating IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54Figure 1 1 1 1 1 1 1 1 2 2 2 3
24
Junction box
Figure 1 Figure 2 Figure 3
L C CB6
C CuA Al
Dimension A08
95004 400A 20 2000A06 600A 25 2500A08 800A 32 3200A10 1000A 40 4000A12 1250A 50 5000A15 1500A 64 6400A16 1600A
CB Center tap box3 3φ3W 100%G4 3φ3W 50%G5 3φ4W 100%G6 3φ4W 50%G7 3φ4W 0%G8 3φ4W 50%N 0%G9 3φ3W 0%G
10 3φ4W 50%N 50%G ※屋外型接線箱尺寸詳圖, 須另提供技術圖面以供套圖11 3 φ4W 200%N 50%G
※For outdoor junction boxes, additional technical diagrams are required for compiling the dimensions
CopperBusway Ratings 600A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
W mm 205 220 233 260 300 340 380 420 545 625 705W1 mm 55 70 83 110 150 190 230 270 395 475 555IP Rating IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54Figure 1 1 1 1 1 1 1 1 2 2 2
AluminumBusway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A
W mm 220 233 260 280 300 340 380 420 545 625 705 875W1 mm 70 83 110 130 150 190 230 270 395 475 555 720IP Rating IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54Figure 1 1 1 1 1 1 1 1 2 2 2 3
BL
25
Joint expansion
04 400A 20 2000A06 600A 25 2500A08 800A 32 3200A10 1000A 40 4000A12 1250A 50 5000A15 1500A 64 6400A16 1600A
BL C EF6
C CuA Al
EF Expansion fitting
Dimension A08
1200
匯流排直線長度超過50m時,須設伸縮接頭元件
匯流排通過大樓伸縮縫結構處時,須設伸縮接頭元件��
伸縮範圍:匯流排長度+/-40mm移動範圍�
Figure 1 Figure 2 Figure 3
3 3φ3W 100%G4 3φ3W 50%G5 3φ4W 100%G6 3φ4W 50%G7 3φ4W 0%G8 3φ4W 50%N 0%G9 3φ3W 0%G
10 3φ4W 50%N 50%G11 3 φ4W 200%N 50%G
CopperBusway Ratings 600A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
W mm 126 126 139 166 206 246 286 326 451 531 611W1 mm 55 70 83 110 150 190 230 270 395 475 555L mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200IP Rating IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68Figure 1 1 1 1 1 1 1 1 2 2 2
AluminumBusway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A
W mm 126 139 166 186 206 246 286 326 451 531 611 776W1 mm 70 83 110 130 150 190 230 270 395 475 555 720L mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200IP Rating IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68Figure 1 1 1 1 1 1 1 1 2 2 2 3
Where the straight length of busways exceeds 50m, a joint expansion element is requiredWhere busways have to pass a building expansion joint, joint expansion elements are requiredExtension range: Busway length +/-40mm moving range
26
Element code
Flatwise Tee TH Flange end FS Feeder end SE Edgewise Tee TV
Edgewise elbow LV Flatwise elbow LH Plug-in section SPFeeder section SS
L C SS6
C CuA Al
SS Feeder sectionSP Plug-in sectionLV Edgewise elbowLH Flatwise elbow CH Flat to EdgeCV Eage to FlatTV Edgewise TeeTH Flatwise TeeFS Flange end SE Feeder end
Dimension A x B x C08
04 400A 20 2000A06 600A 25 2500A08 800A 32 3200A10 1000A 40 4000A12 1250A 50 5000A15 1500A 64 6400A16 1600A
3 3φ3W 100%G4 3φ3W 50%G5 3φ4W 100%G6 3φ4W 50%G7 3φ4W 0%G8 3φ4W 50%N 0%G9 3φ3W 0%G
10 3φ4W 50%N 50%G11 3 φ4W 200%N 50%G
CopperBusway Ratings 600A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
Feeder section A 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200Plug-in section A mm 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200Edgewise elbow AxB mm 250x250 250x250 250x250 250x250 250x250 250x250 250x250 250x250 250x250 250x250 250x250Flatwise elbow AxB mm 190x190 190x190 190x190 215x215 235x235 255x255 275x275 295x295 360x360 400x400 440x440Edgewise Tee AxB mm 200x490 200x520 200x550 200x600 200x680 200x760 200x840 200x920 200x760 200x840 200x920Flatwise Tee AxB mm 190x380 190x380 190x380 215x430 235x470 255x510 275x550 295x590 360x720 440x880 440x880Flange end A mm 380 380 380 380 380 380 380 380 380 380 380Feeder end A mm 250 250 250 250 250 250 250 250 250 250 250
AluminumBusway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A
Feeder section A 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200Plug-in section A mm 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200 4200Edgewise elbow AxB mm 250x250 250x250 250x250 250x250 250x250 250x250 250x250 250x250 250x250 250x250 250x250 250x250Flatwise elbow AxB mm 190x190 190x190 215x215 225x225 235x235 255x255 275x275 295x295 360x360 400x400 440x440 520x520Edgewise Tee AxB mm 200x520 200x550 200x600 200x640 200x680 200x760 200x840 200x920 200x760 200x840 200x920 200x1240Flatwise Tee AxB mm 190x380 190x380 215x430 225x450 235x470 255x510 275x550 295x590 360x720 400x800 440x880 520x1040Flange end A mm 380 380 380 380 380 380 380 380 380 380 380 380Feeder end A mm 250 250 250 250 250 250 250 250 250 250 250 250
BL
27
Spring hanger
B
140
210 60
A
200
500
Flo
or h
eigh
t
匯流排通過樓層地板開孔時,須設彈簧架支撐 彈簧架支撐負載上限:600kg彈簧架為免調整型,可平均支撐各樓層匯流排重量及熱脹冷縮之位移
M12 Drop rod
Where busways have to pass floor openings, spring hangers are required for sufficient support
Spring hanger load limit: 600kg
Spring hangers require no adjustment, and can evenly support busway weight in all floors and
compensate displacement caused by thermal expansion
CopperBusway Ratings 600A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
Models SH600 SH600 SH600 SH600 SH600 SH600 SH600 SH600 SH600 SH600 SH600Height 1m/weight kg 15.0 20.6 25.5 35.7 50.8 65.9 81.0 96.0 131.8 162.0 192.0Height 3m/weight kg 45.0 61.8 76.5 107.1 152.4 197.7 243.0 288.0 395.4 486.0 576.0Height 4m/weight kg 60.0 82.4 102.0 142.8 203.2 263.6 324.0 384.0 527.2 648.0 768.0Height 5m/weight kg 75.0 103.0 127.5 178.5 254.0 329.5 405.0 480.0 659.0 810.0 960.0Hanger width A mm 165 180 193 220 260 300 340 380 505 585 665Drop rod dimension M12xB mm 105 120 140 160 200 240 280 320 450 530 610Max. tolerance of height m ≦5 ≦5 ≦5 ≦5 ≦5 ≦5 ≦5 ≦5 ≦4 ≦3 ≦3
AluminumBusway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A
Models SH600 SH600 SH600 SH600 SH600 SH600 SH600 SH600 SH600 SH600 SH600 SH600Height 1m/weight kg 20.6 16.9 22.6 26.9 31.2 32.1 48.3 56.8 64.2 96.6 113.6 144.9Height 3m/weight kg 61.8 50.7 67.8 80.7 93.6 96.4 144.9 170.4 192.8 289.8 340.8 434.7Height 4m/weight kg 82.4 67.6 90.4 107.6 124.8 128.4 193.2 227.2 256.8 386.4 454.4 579.6Height 5m/weight kg 103.0 84.5 113.0 134.5 156.0 160.5 241.5 284.0 321.0 483.0 568.0 724.5Hanger width A mm 180 193 220 240 260 300 340 380 505 585 665 830Drop rod dimension M12xB mm 120 140 160 180 200 240 280 320 450 530 610 775Max. tolerance of height m ≦5 ≦5 ≦5 ≦5 ≦5 ≦5 ≦5 ≦5 ≦5 ≦5 ≦5 ≦4
28
Wall/Floor Flange
CopperBusway Ratings 600A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A
Models WF0600 WF0804 WF1006 WF1208 WF1612 WF2000 WF2516 WF3220 WF4025 WF5032 WF6440h x w mm 100x55 100x70 100x83 100x110 100x150 100x190 100x230 100x270 100x395 100x475 100x555A mm 155 170 183 210 250 290 330 370 495 575 655B mm 200 200 200 200 200 200 200 200 200 200 200C mm 258 272 286 313 352 392 432 472 600 680 760D mm 109 116 123 91 104 88 98 108 112 128 90
AluminumBusway Ratings 400A 600A 800A 1000A 1250A 1500A 1600A 2000A 2500A 3200A 4000A 5000A
Models WF0804 WF1006 WF1208 WF0010 WF1612 WF2000 WF2516 WF3220 WF4025 WF5032 WF6440 WF0050h x w mm 100x70 100x83 100x110 100x130 100x150 100x190 100x230 100x270 100x395 100x475 100x555 100X720A mm 170 183 210 230 250 290 330 370 495 575 655 820B mm 200 200 200 200 200 200 200 200 200 200 200 200C mm 272 286 313 334 352 392 432 472 600 680 760 925D mm 116 123 91 98 104 88 98 108 112 128 90 177
B
A
A
h
w
B
C
240
C
20D
100
240
DD
D 2020
Wall/Floor Flange穿牆法蘭開孔尺寸穿牆開孔尺寸Through-wall opening dimensions
Wall/Floor Flange opening dimensions