demonstration paper: personalized physical activity ...€¦ · expenditure estimation using a...

2
Demonstration Paper: Personalized Physical Activity Monitoring on the Move Marco Altini 1,2 , Julien Penders 1 , Ruud Vullers 1 1 Holst Centre - imec The Netherlands Eindhoven, The Netherlands [email protected] Oliver Amft 2 2 ACTLab, Signal Processing Systems Eindhoven University of Technology Eindhoven, The Netherlands ABSTRACT Accurate Energy Expenditure (EE) estimation is key in un- derstanding how behavior and daily Physical Activity (PA) patterns affect health. Mobile phones and wearable sen- sors (e.g. accelerometers (ACC) and heart rate (HR) mon- itors) have been widely used to monitor PA. In this paper we present a real-time implementation of activity-specific EE estimation algorithms, using an Health Patch and an iPhone. Our approach to continuous monitoring of PA tar- gets personalized behavior and health status assessment, by automatically accounting for a person’s cardiorespiratory fit- ness level (CRF), which is the main cause of inter-individual variation in HR during moderate to vigorous activities. The proposed system opens new opportunities for personalized health assessment in daily life, using ubiquitous devices. Categories and Subject Descriptors J.3 [Computer Applications]: Life & medical sciences— Health General Terms Algorithms, Experimentation 1. INTRODUCTION To determine the links between PA and health, accurate quantification of habitual PA in ambulatory settings is es- sential. New technologies able to monitor objectively and non-invasively our behavior can provide unprecedented in- sights on these links. Among these technologies, ACC and HR monitors are the most widespread. The most advanced algorithms combine ACC and HR in activity-specific mod- els, dividing the estimation process into two steps. First, the activity performed is determined. Secondly, an activity- specific equation is applied to estimate EE. However, regard- less of the methodology used, HR-based algorithms typically require individual calibration to cope with the substantial inter-individual differences in the relation between HR and Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. To copy otherwise, to republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Wireless Health 0 13, Nov 1-3, 2013, Baltimore, MD, USA Copyright 2013 ACM 978-1-4503-2290-4/13/11 ...$10.00. EE. During moderate to vigorous PA, differences in HR be- tween individuals are mainly due to CRF. Thus, we propose a real-time implementation of an HR normalization proce- dure that, based on daily life activities, can automatically es- timate CRF-related variance and personalize EE estimates. 2. THE NEED FOR PERSONALIZATION The main cause of differences in the HR-EE relation dur- ing activity is CRF. An individual with higher CRF (i.e. more fit), will have a lower HR during exercise. Fig. 1 shows the relation between HR and EE for two subjects. Given the similar body size, EE is almost the same, while HR is very different, due to higher fitness level of subject 20. Since EE is derived from HR, the outcome will be over or under-estimated. Individual calibration is not practically feasible since it requires each user to perform tests, using an indirect calorimeter. Thus, alternative methods to tackle the problem are needed to objectively and accurately esti- mate EE at the individual level, and not only as group av- erages. When normalizing HR, we are interested in the HR the different individuals would reach when performing the same activity, at the same workload. This HR at a constant workload is representative of CRF, and can be used to nor- malize HR. We selected running at 10km/h as the constant workload (HR normalization factor), since running at 10 to 12 km/h could explain 88% of the variance in VO2 max in past research [2], showing that it well represents CRF. Figure 1: Relation between HR and EE for two sub- jects with similar body size but different CRF level.

Upload: others

Post on 23-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Demonstration Paper: Personalized Physical Activity ...€¦ · Expenditure Estimation Using a Cardiorespiratory Fitness Predicate. Pervasive Health 2013. in-press. [2] J.D. George

Demonstration Paper: Personalized Physical ActivityMonitoring on the Move

Marco Altini1,2, Julien Penders1,Ruud Vullers1

1Holst Centre - imec The NetherlandsEindhoven, The [email protected]

Oliver Amft22ACTLab, Signal Processing SystemsEindhoven University of Technology

Eindhoven, The Netherlands

ABSTRACTAccurate Energy Expenditure (EE) estimation is key in un-derstanding how behavior and daily Physical Activity (PA)patterns affect health. Mobile phones and wearable sen-sors (e.g. accelerometers (ACC) and heart rate (HR) mon-itors) have been widely used to monitor PA. In this paperwe present a real-time implementation of activity-specificEE estimation algorithms, using an Health Patch and aniPhone. Our approach to continuous monitoring of PA tar-gets personalized behavior and health status assessment, byautomatically accounting for a person’s cardiorespiratory fit-ness level (CRF), which is the main cause of inter-individualvariation in HR during moderate to vigorous activities. Theproposed system opens new opportunities for personalizedhealth assessment in daily life, using ubiquitous devices.

Categories and Subject DescriptorsJ.3 [Computer Applications]: Life & medical sciences—Health

General TermsAlgorithms, Experimentation

1. INTRODUCTIONTo determine the links between PA and health, accurate

quantification of habitual PA in ambulatory settings is es-sential. New technologies able to monitor objectively andnon-invasively our behavior can provide unprecedented in-sights on these links. Among these technologies, ACC andHR monitors are the most widespread. The most advancedalgorithms combine ACC and HR in activity-specific mod-els, dividing the estimation process into two steps. First,the activity performed is determined. Secondly, an activity-specific equation is applied to estimate EE. However, regard-less of the methodology used, HR-based algorithms typicallyrequire individual calibration to cope with the substantialinter-individual differences in the relation between HR and

Permission to make digital or hard copies of all or part of this work forpersonal or classroom use is granted without fee provided that copies arenot made or distributed for profit or commercial advantage and that copiesbear this notice and the full citation on the first page. To copy otherwise, torepublish, to post on servers or to redistribute to lists, requires prior specificpermission and/or a fee.Wireless Health ′13, Nov 1-3, 2013, Baltimore, MD, USACopyright 2013 ACM 978-1-4503-2290-4/13/11 ...$10.00.

EE. During moderate to vigorous PA, differences in HR be-tween individuals are mainly due to CRF. Thus, we proposea real-time implementation of an HR normalization proce-dure that, based on daily life activities, can automatically es-timate CRF-related variance and personalize EE estimates.

2. THE NEED FOR PERSONALIZATIONThe main cause of differences in the HR-EE relation dur-

ing activity is CRF. An individual with higher CRF (i.e.more fit), will have a lower HR during exercise. Fig. 1shows the relation between HR and EE for two subjects.Given the similar body size, EE is almost the same, whileHR is very different, due to higher fitness level of subject20. Since EE is derived from HR, the outcome will be overor under-estimated. Individual calibration is not practicallyfeasible since it requires each user to perform tests, usingan indirect calorimeter. Thus, alternative methods to tacklethe problem are needed to objectively and accurately esti-mate EE at the individual level, and not only as group av-erages. When normalizing HR, we are interested in the HRthe different individuals would reach when performing thesame activity, at the same workload. This HR at a constantworkload is representative of CRF, and can be used to nor-malize HR. We selected running at 10km/h as the constantworkload (HR normalization factor), since running at 10 to12 km/h could explain 88% of the variance in V O2 max inpast research [2], showing that it well represents CRF.

protocol activities

subject 17 subject 20

beats per minute

kcals per minute

Figure 1: Relation between HR and EE for two sub-jects with similar body size but different CRF level.

Page 2: Demonstration Paper: Personalized Physical Activity ...€¦ · Expenditure Estimation Using a Cardiorespiratory Fitness Predicate. Pervasive Health 2013. in-press. [2] J.D. George

Figure 2: Personalized EE estimation system.

We implemented a system able to derive the CRF-relatednormalization factor automatically during daily life, by com-bining HR at rest and during walking activities, in orderto predict an individual’s HR while running at 10 km/h.The algorithm is able to self-adapt and learn from its user,without requiring any individual calibration. The derivedHR normalization factor is used to normalize HR. Then, thenormalized HR is used as a predictor for the activity-specificEE estimation equations (see Fig. 2).

3. SYSTEM ARCHITECTUREThe proposed solution is composed by two hardware com-

ponents, imec’s Health patch [3] and an iPhone. imec’sHealth patch was configured to acquire 128 Hz ECG and 32Hz ACC, extract R-R intervals, and send HR and ACC viaBluetooth Low Energy. The software architecture is detailedin Fig. 2. We extended the architecture of activity-specificEE estimation algorithms, including the components neces-sary to estimate CRF and normalize HR. To automaticallypersonalize the system, HR at rest and while walking, to-gether with walking speed, are stored in a database on thephone. The medians of the last week of HR data in thedifferent activities (rest, walking at 3 to 6 km/h) is used torecalculate the normalization factor daily. This way, changesin CRF will be automatically reflected in changes in normal-ized HR and used to properly estimate EE.

protocol activities

subject 17 subject 20

normalized heart rate

Figure 3: Qualitative result of the HR normalizationprocedure for the same subjects of Fig. 1.

Figure 4: iPhone app and imec’s Health patch.

4. ALGORITHMS IMPLEMENTATIONOffline models were developed using data from 29 partic-

ipants performing a wide set of PAs [1]. Online versions ofthe regression models (walking speed, normalization factorand EE estimations) use the same features as the offline ver-sions, thus accuracy is not affected by the online implemen-tation. On the other hand, the activity recognition modelwas modified to ease implementation on the phone. The sys-tem can recognize six clusters of activities (lying, sedentary,dynamic, walking, biking and running). Accuracy was 87%,compared to the 94% of the offline version, due to highermisclassification for biking. In future versions we plan to in-tegrate GPS data to increase accuracy. Walking speed wasestimated using ACC features and the individual’s height(RMSE = 0.28±0.09km/h). Another regression model wasbuilt to predict the normalization factor using activities ofdaily living. The model relies on HR while lying resting andwhile walking at 4, 5 and 6 km/h, together with the individ-ual’s height and age (RMSE = 8.3 beats per minute). ActualHR measurements are then divided by the normalization fac-tor. Fig. 3. shows a qualitative result of the effect of the HRnormalization. We implemented six activity-specific EE lin-ear models, and used the normalized HR, ACC and anthro-pometric features to estimate EE (RMSE = 0.60kcal/min).Reduction in error using the normalization factor rangedbetween 3 and 33% for the different clusters.

5. DEMOReal-time activity recognition and personalized activity-

specific EE estimates will be shown using an iPhone app,connected to imec’s Health patch (see Fig. 4).

6. REFERENCES[1] M. Altini, J. Penders, O. Amft. Personalizing Energy

Expenditure Estimation Using a CardiorespiratoryFitness Predicate. Pervasive Health 2013. in-press.

[2] J.D. George et al. Development of a submaximaltreadmill jogging test for fit college-aged individuals.Med Sci Sports Exerc.1993 ;25:643-647.

[3] M. Altini et al. An ECG patch combining acustomized ultra-low-power ECG SoC with Bluetoothlow energy for long term ambulatory monitoring. inProceedings of the 2nd Conference on Wireless Health.2011, ACM: San Diego, California. p. 1-2