densité 3 frame - video data · 62 ‰ 3 frame densitÉ modular products key features and benefits...
TRANSCRIPT
62 WWW.MIRANDA.COM/DENSITÉ 3 FRAME
DENS
ITÉ
MOD
ULAR
PRO
DUCT
S
KEY FEATURES AND BENEFITS
› Multiple video and audio formats can be fitted in a single frame
› Backwards compatible with Densité 2 modules
› Easy configuration by front panel or remotely via the optional Ethernet frame controller
› Choice of control panels, including the RCP-200 advanced remote panel and the PC-based iControl Solo GUI
› External power supply with locking connector, and a second connector for a redundant power supply (option)
› Supports full range of Densité Series modules
› Frame can be stacked without additional cooling spaces
› Ethernet frame controller optional with redundant Ethernet connection
› 1RU tray for rack mount installation of up to two Densité 3 mini frames
TECHNICAL SPECIFICATIONS
MECHANICALDimensions: 3RU x 19 in (485 mm) x 11.25 in
(286 mm) with connectorsWeight: 10.2 lb (4.6 kg), 1 PSU and 1
controller
POWERInput range: AC 50-60 Hz, 100-240 VRating: 300 W Max
CONTROL AND MONITORINGCommunication ports: Ethernet 10/100 Base-TAlarm: GPI contact
COOLINGFans: 1 on frame 1 on each PSUSound pressure level: 8.9 dBA (1 m in front of unit)Operating temp. range: 0-40 °C
ORDERING INFORMATION
Densité 3 Housing frame with (1) PSU (AC in), (1) Ethernet controller with front control panel, blank rear panels
Note: Rear panels must be specified and ordered with appropriate cards.
OPTIONS DESCRIPTIONDensité 3-PSU-AC Redundant PSU for Densité 3Densité-CPU-ETH2-OPT-LNK Full link redundancy using channel bonding on Densité-CPU-ETH2
Densité 3 Frame20 multiformat cards in 3RU
DESCRIPTION
The 3RU Densité 3 Frame can simultaneously process 3Gbps, HD, SD, and analog video, as well as AES and analog audio and can be fitted with 3RU or 2RU Densité modules (using card extenders). Its front-opening frame features dual hot swappable power supplies (PSUs) and fans. Modules for the air-cooled frame are
also hot swappable, and replacement modules can be configured automatically. All modules, redundant PSUs and fans are monitored to deliver status via GPI or an optional Ethernet port. Front panel multi-color LEDs provide status reporting, while a controller card allows card adjustments by the front panel.
B4
B2
2RU Densité card
Extender panel for 2RU Densité card
Densité 2RU rear panel
Extender panel for Densité 2RU modules
Densité 3RU rear panel
3RU Densité card
FITTING 3RU AND 2RU CARDS IN DENSITÉ 3 FRAMEThe Densité 3 frame can host any of the 3RU Densité modules, but is also backwards compatible with any 2RU Densité modules. This backwards compatibility involves fitting blank extenders to 2RU modules.