General DECOR SERIES RADIATOR Installation Guide Connections: 4 - 1/2" B.S.P. (British Standard Pipe) 2 per side Maximum positive operating pressure: Standard design: 72 psi Maximum positive operating pressure: High-pressure design: 116 psi Maximum operating temperature: 230° F rectangular steel tubes, 2-3/4"x7/16"x16 ga. rectangular steel tubes, 2-3/4"x7/16"x14 ga. Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com A variety of matching valves and other accessories are available and recommended from MYSON. For specific applications see our detailed installation and technicals manuals and price book which are available on our web site. It is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Myson radiators should only be used with recirculation pump closed loop hydronic heating systems such as 2 pipe reverse return, 2 pipe direct return, 1 pipe monoflo or homerun piping systems. Series loop piping is not recommended. Myson radiators are not for use in gravity or steam systems. Position your radiator away from your circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could draw air into the system. The suggested location for your Myson radiator, where possible, is below a window where it can minimize downdrafts from glazed areas. Mounting the radiator a minimum of 4 inches off the floor willaprovideaforaadequateaconvection.aa(3 3 / 16 "aminimumafora2Habaseboard) Myson radiators are supplied with drain plugs, vent plugs, and mounting brackets. Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and property damage NOT covered under the Myson Warranty. Step 1 Fill and vent the system. Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position. Step 3 Shut off and drain the system while the water is still hot. Step 4 Refill the system. Step 5 Reheat, vent, and balance the system. Step 6 Once the Décor Radiator is filled with water the system should be left filled. Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired as automatic system fill valves allow fresh water/oxygen into the system attacking radiators internally. SYSTEM START-UP MAINTENANCE & CLEANING 1 Once operating, avoid the introduction of fresh water and oxygen to the system to prevent corrosion. 2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect the finish of your Myson radiator. 3 The use of abrasive cleaners will damage the surface of your radiator and void the manufacturer’s warranty. DESIGN AND LAYOUT CONSIDERATIONS: NOTE! For optimum performance connect the supply to the top and the return to the bottom of the opposite side. Bottom supply and return will result in a 5% reduced heat output. (See online manual for detailed piping diagrams.) VALVE ROUGH-IN: When using Myson radiator valves to install your radiator add the following distance from the end of the radiator to the center of your Supply/Return pipe for each valve. For 2TRV1/2AN and LKD16AN valves add 1-3/4" --- For 2TRV1/2IN and FF16LAC/FF16WAC valves add 1-5/8" MOUNTING: Myson horizontal radiators 3H to 11H are supplied with welded mounting lugs located 6-15/16" in from each end. Myson vertical radiators V11 are supplied with welded mounting lugs located 4-1/4" in from each end (top and bottom). Pedestal style radiators H34 are supplied with adjustable height stands. Myson baseboard style radiators 2H are supplied with the appropriate number of brackets for each length. (See Mounting Detail Supplement for more information) For more detailed bracket installation dimensions and mounting positions please consult the detailed installation manual available at MysonComfort.com and/or the assembly instructions included with the mounting brackets. SAFETY PRECAUTIONS Radiators are hot when in use, and as such, present a risk of burns to users on prolonged contact. The temperature of a radiator is dependent on the temperature of the system water, as set by the system installer or user. Installers and users should take all necessary steps to minimi ze the risks of burns. If the risk is significant, consideration should be given to installing low surface temperature radiators, or to placing guards in front of the radiators. For the correct installation of radiators it is essential that the mounting of the radiator to the wall is carried out in such a way that it is suitable for intended use AND predictable misuse. VENT LOCATION: The radiator vent should be located on the return side of the radiator at the top tapping. DECOR 10 10 10 MAR 2016

Upload: others

Post on 25-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DESIGN AND LAYOUT CONSIDERATIONSs3.amazonaws.com/media.blueridgecompany.com/documents...VALVE ROUGH-IN: When using Myson radiator valves to install your radiator add the following

General

DECOR SERIES RADIATOR Installation Guide

Connections: 4 - 1/2" B.S.P. (British Standard Pipe) 2 per side

Maximum positive operating pressure: Standard design: 72 psi Maximum positive operating pressure: High-pressure design: 116 psi

Maximum operating temperature: 230° F

rectangular steel tubes, 2-3/4"x7/16"x16 ga.

rectangular steel tubes, 2-3/4"x7/16"x14 ga.

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

A variety of matching valves and other accessories are available and recommended from MYSON. For specific applications see our detailed installation and technicals manuals and price book which are available on our web site.

It is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade.

Myson radiators should only be used with recirculation pump closed loop hydronic heating systems such as 2 pipe reverse return, 2 pipe direct return, 1 pipe monoflo or homerun piping systems. Series loop piping is not recommended. Myson radiators are not for use in gravity or steam systems. Position your radiator away from your circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could draw air into the system. The suggested location for your Myson radiator, where possible, is below a window where it can minimize downdrafts from glazed areas. Mounting the radiator a minimum of 4 inches off the floor willaprovideaforaadequateaconvection.aa(33/16"aminimumafora2Habaseboard)Myson radiators are supplied with drain plugs, vent plugs, and mounting brackets.

Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and property damage NOT covered under the Myson Warranty.

Step 1 Fill and vent the system.Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position. Step 3 Shut off and drain the system while the water is still hot. Step 4 Refill the system.Step 5 Reheat, vent, and balance the system.Step 6 Once the Décor Radiator is filled with water the system should be left filled.Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired

as automatic system fill valves allow fresh water/oxygen into the system attacking radiators internally.

SYSTEM START-UP

MAINTENANCE & CLEANING1 Once operating, avoid the introduction of fresh water and oxygen to the system to prevent corrosion. 2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect the finish of your Myson radiator.3 The use of abrasive cleaners will damage the surface of your radiator and void the manufacturer’s warranty.

DESIGN AND LAYOUT CONSIDERATIONS:

NOTE! For optimum performance connect the supply to the top and the return to the bottom of the opposite side. Bottom supply and return will result in a 5% reduced heat output. (See online manual for detailed piping diagrams.)

VALVE ROUGH-IN: When using Myson radiator valves to install your radiator add the following distance from the end of the radiator to the center of your Supply/Return pipe for each valve. For 2TRV1/2AN and LKD16AN valves add 1-3/4" --- For 2TRV1/2IN and FF16LAC/FF16WAC valves add 1-5/8"

MOUNTING: Myson horizontal radiators 3H to 11H are supplied with welded mounting lugs located 6-15/16" in from each end. Myson vertical radiators V11 are supplied with welded mounting lugs located 4-1/4" in from each end (top and bottom). Pedestal style radiators H34 are supplied with adjustable height stands. Myson baseboard style radiators 2H are supplied with the appropriate number of brackets for each length. (See Mounting Detail Supplement for more information)

For more detai led bracket instal lation dimensions and mounting posit ions please consult the detai led instal lation manual available at MysonComfort.com and/or the assembly instructions included with the mounting brackets.

SAFETY PRECAUTIONSRadiators are hot when in use, and as such, present a risk of burns to users on prolonged contact. The temperature of a radiator is dependent on the temperature of the system water, as set by the system installer or user. Installers and users should take all necessary steps to minimize the risks of burns. If the risk is significant, consideration should be given to installing low surface temperature radiators, or to placing guards in front of the radiators.

For the correct installation of radiators it is essential that the mounting of the radiator to the wall is carried out in such a way that it is suitable for intended use AND predictable misuse.

VENT LOCATION: The radiator vent should be located on the return side of the radiator at the top tapping.

DECOR

1010

10

MAR 2016

Page 2: DESIGN AND LAYOUT CONSIDERATIONSs3.amazonaws.com/media.blueridgecompany.com/documents...VALVE ROUGH-IN: When using Myson radiator valves to install your radiator add the following

Horizontal & Vertical design, H & V models

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

Sid

e C

on

ne

ctio

ns:

All Dimensions are nominal

H34 Pedestal

6-7/8"1

-7/8

"

H11 1"

H22 1-7

/8"

3-11/16"

2-11/16"

8-7/16"

5-5/8"

11-1/4"

16-15/16"

22-5/8"

31-1/8"

Overall Heights Overall Lengths

2-11/16"

V11

78

-3/4

"

V11

1"

3/16"3/16"

2-11

/16"

13/16" Typical

Overall Length

76

-3/4

"

5-5/8" 1/2" BSP 489 3512H11

Height Model 1600F 1400F1800F

3H11 8-7/16" 1/2" BSP 618 443

627

791

8H11

11H11

6H22

8H22

11H22

2H34

4H11

6H11

11-1/4" 1/2" BSP

16-15/16" 1/2" BSP

22-5/8" 1/2" BSP

31-1/8" 1/2" BSP

16-15/16" 1/2" BSP

22-5/8" 1/2" BSP

31-1/8" 1/2" BSP

ADJUSTABLE PEDESTAL 1/2" BSP

985 769 552

1,466 1,143 821

1,778 1,387 996

2,106 1,663 1,197

2,740 2,137 1,535

3,848 3,001 2,155

2,026 1,580 1,135

1,8182,5323,246

Btuh/FT at Listed AWT and EAT of 700 F.

W

4" Minimum

X

1-3/4"

3-3/8"

V11

H11/H22

H34

Measurement X: chosen distance between the wall or window surface and the back of the convector.

6-9

/16

"

6-7

/8"

X

3-1

/2"

3-3/16"Min

1-7/16"

3-1/8"

2H11BB

558

1700F

705

877

1,305

1,582

1,885

2,439

3,425

1,803

2,889

420

1500F

531

661

982

1,191

1,442

1,836

2,578

1,357

2,175

282

1300F

357

444

660

800

976

1,234

1,732

912

1,461

213

1200F

271

336

498

605

755

933

1,309

689

1,104

5.25

Weight(lbs/ft)

7.62

9.75

13.34

17.57

22.54

24.82

32.94

42.38

16.08

.09

Wtr Content gals/ft

.13

.18

.26

.36

.49

.54

.72

.99

.26

5V11

6V11

8V11

10V11

78-3/4" 1/2" BSP

1/2" BSP

1/2" BSP

1/2" BSP

4,009 3,127 2,245

4,018 3,134 2,250

4,018 3,134 2,250

2,2473,1304,013

3,568

3,576

3,576

3,572

2,686

2,692

2,692

2,689

1,804

1,808

1,808

1,806

1,363

1,366

1,366

1,365

49.52

49.52

49.52

49.52

1.12

1.12

1.12

1.12

4H34 1/2" BSP 2,593 1,8622,959 2,228 1,497 1,132 31.20 .54

**100 **120 **140 **160 **180 **200 **220 **240

23-5/8" 31-1/2" 35-7/16"35-7/16" 47-1/4" 55-1/8" 63" 70-7/8" 78-3/4" 86-5/8" 94-1/2"

Model Length **060 **080

Nominal Length

**090 **300

118-1/8" 39-3/8" (cm)

(in)

3,324

5V11 6V11 8V11 10V11

14-1/8" 16-15/16" 22-5/8" 28-1/4"

VERTICAL MODELS

ADJUSTABLE PEDESTAL

78-3/4"

78-3/4"

78-3/4"

Connections 2 per side

DECOR SERIES Specification Data

XMounting Bracket

3

Dimension (in) Dimension (in)XW W

Type H11 Type H22

15/16 47/8 31/16

33/8 111/16 51/4 37/16

KOM (BH)Short Side*KOM (BH)Long Side*

* From wall to radiator