eckersley Garden Architecture Eckersley Garden Architecture Pty Ltd PO Box 5004 Burnley 3121 Victoria Australia T +61 3 9421 5537 F +61 3 9421 4415 [email protected] www.e-ga.com.au All measurements must be verified on site before commencing any construction. All works requiring engineering specifications must be independently designed by consultant engineers. Levels and step numbers to be verified on site. Details and listings to follow on A4 format. Additional Information This drawing is copyright and remains the property of Eckersley Garden Architecture. Date 23.JAN.13 Scale 1:300 (A1) Rev D Drawn KE Project Hotel & Conference Centre Murchison Street Marysville Client METIER 3 Drawing Title LANDSCAPE PLAN Drawing No. MET-0113-05-03 DESIGN DEVELOPMENT 414000 Surface Level 413000 Surface Level 416000 Surface Level NPW (x1430) NDO (x57) TAS (x40) UP ACO (x67) NPW (x1704) NPW (x1275) NPW (x49) NPW (x2432) CPP (x20) JUS (x20) CPP (x13) JUS (x13) CPP (x13) JUS (x13) CPP (x13) JUS (x13) CPP (x5) JUS (x5) PNA (x209) TAS (x41) CPP (x20) JUS (x20) CPP (x13) JUS (x13) CPP (x7) JUS (x7) CPP (x6) JUS (x6) MSG (x339) NDO (x328) TAS (x101) PNA (x134) TAS (x26) CPP (x169) JUS (x169) NDO (x222) TAS (x68) NDO (x1955) MSG (x206) MSG (x415) MSG (x358) MSG (x412) MSG (x261) TAS (x51) NDO (x68) NDO (x43) NDO (x76) NDO (x76) NDO (x315) TAS (x219) LMR (x630) PNA (x435) MSG (x1452) CPP (x224) JUS (x224) EIV (x70) EIV (x226) EIV (x86) ACO (x99) ACO (x36) ACO (x24) ACO (x45) ACO (x54) CPP (x20) JUS (x20) CPP (x13) JUS (x13) CPP (x13) JUS (x13) CPP (x13) JUS (x13) CPP (x5) JUS (x5) CPP (x17) JUS (x17) CPP (x13) JUS (x13) CPP (x7) JUS (x7) CPP (x6) JUS (x6) CPP (x20) JUS (x20) CPP (x13) JUS (x13) CPP (x13) JUS (x13) CPP (x13) JUS (x13) CPP (x5) JUS (x5) CPP (x16) JUS (x16) CPP (x13) JUS (x13) CPP (x7) JUS (x7) CPP (x6) JUS (x6) PNA (x3) PNA (x3) PNA (x3) NDO (x185) TAS (x94) 414.95 QPA (x1) BPD (x3) BPD (x3) BPD (x2) BPD (x4) BPD (x3) BPD (x1) BPD (x3) BPD (x5) BPD (x5) BPD (x3) QPA (x5) BPD (x8) UPA (x5) UPA (x5) UPA (x5) UPA (x5) BPD (x3) UPA (x10) UPA (x1) EIV (x198) EIV (x86) EIV (x141) CES (x41) PQU (x10) 420900 Surface Level RAINGARDEN - To Civil Engineers specification RAINGARDEN - To Civil Engineers specification RAINGARDEN - To Civil Engineers specification RAINGARDEN - To Civil Engineers specification TJA (x78) M O W N L A W N Elms Trees 1:35 Slope falls 2m x 70m UP UP UP UP M O W N L A W N M O W N L A W N M O W N L A W N M O W N L A W N Water Tank 1:20 Slope falls 1.25m over 26m 1:400 Slope falls 0.1m over 41m HEAVY VEHICLE ACCESS BATTER R O U G H L A W N 1:16 RAMP U P GAS TANK 2 X 7000L HEAVY VEHICLE ACCESS CARPARK P O O L 1:16 WATER TANK 418000 Surface Level 417900 Surface Level 417500 Surface Level 423000 Surface Level 421000 Surface Level 423000 Surface Level 419850 Surface Level 418250 Surface Level 417100 Surface Level 421000 Surface Level 421040 Surface Level 417590 Surface Level 417000 Surface Level 416500 Surface Level 416000 Surface Level 415500 Surface Level 414500 Surface Level 414300 Surface Level 412500 Surface Level 410600 Surface Level 415250 Surface Level 416000 Surface Level 415000 Surface Level 414500 Surface Level 416000 Surface Level 415000 Surface Level 415370 Surface Level 413500 Surface Level 414750 Surface Level 416000 Surface Level 414650 Surface Level 415000 Surface Level 419000 Surface Level 418000 Surface Level 417000 Surface Level 416000 Surface Level 421000 Surface Level 420000 Surface Level 422000 Surface Level 423000 Surface Level B A T T E R 416915 Surface Level 417285 Surface Level 417100 Surface Level 417200 Surface Level Low Garden Bed - Planting TBC by Council Low Garden Bed - Planting TBC by Council Concrete slab for GAS TANK - to Engineers specs - dimensions TBC P L A N T E D B A T T E R RAMP GREASE TRAP - Refer HYD ENG DWGS SUBSTATION BINS 423570 Surface Level 420960 Surface Level GATE B A T T E R Cut outs in paving - 1m diam - Planting around tree base 416390 Surface Level 417920 Surface Level 417800 Surface Level 200mm x 200mm cut outs in paving - base of each post, front & back - creeper to grow up BATTER AROUND COURT EDGES AS REQUIRED 412500 Surface Level 411300 Surface Level 417000 Surface Level 413500 Surface Level WATER TANK 421040 Surface Level 420860 Surface Level 419500 Surface Level 419000 Surface Level 417000 Surface Level 412000 Surface Level CHAPEL - To Architects Design Low Garden Bed - Planting TBC by Council UP UP 421540 Surface Level 420940 Surface Level Raised Planter - to Architects spec Raised Planter - to Architects spec Retaining Wall - To Architects spec Balustrade - Timber Frame & Stainless wire - See elevations Cut Across corner - To Allow Council foot path to be reinstated Sleeper Retaining Wall - Painted Dulux "NAMADJI" - See elevation 1:26 Slope falls 0.5m over 13m 418 417 416 416.200 415 414 413 412 B A T T E R 419199 Surface Level 414775 Surface Level 411250 Surface Level 411250 Surface Level 414775 Surface Level 418725 Surface Level 417990 Surface Level 417990 Surface Level 418530 Surface Level 420450 Surface Level 420450 Surface Level 419900 Surface Level 418530 Surface Level 420950 Surface Level 421430 Surface Level 421430 Surface Level 421761 Surface Level PLANT SCHEDULE SYM Botanical Name Common Name Mat. Height Mat. Spread Spacing Pot Size Quantity Trees BPD Betula pendula 'Dalecarlica' Silver Birch 11m 6m As plan 30cm 43 CES Cedrela sinensis Chinese Toon Tree 8m 3.5m As plan 14cm 41 QPA Quercus palustris Pin Oak 18m 10m As plan 30cm 6 UPA Ulmus parvifolia Chinese Or Lacebark Elm 10 - 15m 10 - 15m As Plan 30cm 31 Shrubs EIV Escallonia iveyii White Escallonia 3m 3m 750mm Tube 1305 NDO Nandina domestica Sacred Bamboo 2m 0.8m 500mm Tube 3325 Perennials NPW Narcissus 'Paper White' White Jonquils 0.5m 0.3m As plan Bulbs 6890 Strap Leaf Plants & Grasses LMR Liriope muscari 'Royal Purple' Purple Turf Lily 0.3m 0.4m 300mm Tube 630 MSG Miscanthus sinensis 'Gracillimus' Eulalia 1.2 - 2.1m 0.9 - 1.2m 400mm Tube 3918 PNA Pennisetum 'Nafray' Fountain Grass 0.6m 0.6m Tube 787 Ground Covers ACO Aptenia cordifolia Baby sun rose 0.3m 0.4m 300mm 14cm 325 TAS Trachelospermum asiaticum Creeping Star Jasmine 0.3m 1.2m 500mm Tube 640 Climbers PQU Parthenocissus quinquefolia Virginian Creeper Structure Size Structure Size Up Wire 14cm 10 TJA Trachelospermum jasminoides Chinese Star Jasmine 8.0m 0.3m Structure Size Tube 78 Aquatic Plants CPP Carex appressa Tall Sedge 0.9 - 1.5m 0.3 - 0.6m As plan Tube 716 JUS Juncus usitatus Common Rush 0.9 - 1.5m 0.6 - 0.9m As Plan Tube 716 (E) Existing (T) Transplant Notes Plant pot sizes and numbers will be determined by stock availability at the time of installation. Spacing is indication only. Numbers to be spread evenly over the area indicated on the plan. * Plants supplied to be hedged should be full and bushy. All to be of similar shape and size ** Trees supplied in 30cm pots should be a minimum of 1.5m high from top of pot and single trunked. All should be of similar shape and size. Double staking may be required. *** Trees supplied as Advanced should be a minimum of 2.5m plus high from top of pot and single trunked. All should be of similar shape and size. Double staking may be required. SITE SPECIFICATION Sleeper Walls Sleeper walling is to be constructed with galvanised steel H beam posts. Treated Pine sleepers set between posts to required height. Ensure footings and walling are constructed to structural engineers specifications and to Australian Standards. Planting Planting shall be carried out using accepted horticultural practices with all plants conforming to the species, size and quantities indicated on the Landscape Plan and Plant Schedule. Plants shall be thoroughly soaked through immersion in water prior to planting and if the planting soil is very dry then the planting hole is also to be filled with water and allowed to drain completely. The root-ball of semi-advanced trees is to be well irrigated rather than immersed. All plants shall be appropriately hardened off in the nursery. Use plants with the following characteristics: Large healthy root systems with no evidence of root curl or pot bound restriction or damage, vigorous, well established, free from disease and pests and of good form, consistent with the species or variety, hardened off – not soft or forced. Plants that do not meet these requirements will be rejected. Planting holes for shrubs and groundcovers are to be of minimum size 75mm larger than the planting pot in all directions. Semi-advanced tree planting holes are to be the same depth as the root-ball and 2-3 times its diameter, with the top of the root- ball being at grade. Planting holes are not to be excavated using an auger unless the edges of the hole are later broken up using a spade or similar. The use of augers can smooth the side of the hole and lead to root girdling. A 75mm high berm is to be constructed at edge of root-ball to hold water. All plants are to be thoroughly watered after planting and slow release fertiliser added at the quantities specified by the manufacturer. NOT FOR CONSTRUCTION Lighting - Ground Mount LED Luminaire - from garden spike Lighting - 'HANGING LIGHTS' - from tree Lighting - Recessed Bridge Rectangular Led Lighting - Ground Mount 2LED Luminaire - from garden spike Lighting - Car Park - P1 Lighting - Car Park - P1 SURFACES Regular Coloured Concrete - Colour TBC Pool NOTES - All measurements must to be checked and verified on site. - Lighting shown for information only. - For further information, these drawing are to be read in conjunction with AECOM Hydraulic & Fire Engineers and Meinhart Civil Engineers design documentation. Lawn - fine mown Asphalt Heavy Vehicle Access - Car Park Asphalt - Car Park & Hotel Entrance Pebbles beds - Rain garden river pebbles Tree Grate - Water drainage Lawn - rough mown Garden beds - '5 way blend' with existing soil Retaining wall - Treated Pine Timber Sleepers Compact Gravel - Class 4 Brown 5mm - Dust Crushed Aggregate with bonding agent Steps - 'Myrtle' 600x300x35mm Bullnose Hardstand Coloured Concrete - Colour TBC Crazy Paving - Kanmantoo Bluestone UP Plain Concrete - Colour TBC Paving - Bluestone 100x100mm grid - tactile treads Tactile Treads SITE SPECIFICATION Mulching Organic mulch is to be supplied to all garden beds and is to be of chipped or shredded vegetable material with 80% of particles in the size range 25 to 50mm in plan and 5 to 10mm in thickness. No particles are to exceed 75mm in plan. Mulch shall be free of deleterious and extraneous matter such as soil, weeds and sticks. Mulch is to be stockpiled and thoroughly weathered prior to delivery. This mulch shall be laid to a minimum depth of 100mm and is to be sloped towards plant stems and kept 100mm back from the steams of all plants to prevent collar rot. Irrigation An approved Netafim irrigation system is to be supplied to all garden beds and planter boxes. It is the responsibility of the contractor to ensure that all irrigation meets Netafim specifications. This system is to be comprised of drip irrigation to all garden beds and planter boxes including a rain-shut off device and timer. Plant Establishment Period There shall be a 13 week plant Establishment Period following the approval of Practical Completion by the responsible authority. During this period the landscape contractor shall make good all defects in his / her scope of works. Maintenance and Establishment means the care and maintenance of the contract area by accepted horticultural practices, as well as rectifying any defects that become apparent in the work under normal use. This shall include, but shall not be limited to watering, fertilising, weeding, pruning, pest and disease control, cultivation, re-staking and replacement of any plants that fail or are damaged with plants of the same species and size.

Upload: others

Post on 26-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DESIGN DEVELOPMENT NOT FOR CONSTRUCTION

eckersleyGarden Architecture

Eckersley Garden Architecture Pty LtdPO Box 5004 Burnley 3121 Victoria Australia T +61 3 9421 5537 F +61 3 9421 [email protected] www.e-ga.com.au

All measurements must be verifi ed on site before commencing any construction.All works requiring engineering specifi cations must be independently designed by consultant engineers. Levels and step numbers to be verifi ed on site. Details and listings to follow on A4 format.

Additional Information

This drawing is copyright and remains the property of Eckersley Garden Architecture.

Date 23.JAN.13

Scale 1:300 (A1)

Rev D

Drawn KE

Project Hotel & Conference CentreMurchison StreetMarysville

Client METIER 3

Drawing Title LANDSCAPE PLAN

Drawing No. MET-0113-05-03

DESIGN DEVELOPMENT

414000Surface Level

413000Surface Level

416000Surface Level

NPW (x1430)

NDO (x57)TAS (x40)

UP

ACO (x67)

NPW (x1704)

NPW (x1275)NPW (x49)

NPW (x2432)

CPP (x20)JUS (x20)CPP (x13)

JUS (x13)CPP (x13)JUS (x13)

CPP (x13)JUS (x13)

CPP (x5)JUS (x5)

PNA (x209)TAS (x41)

CPP (x20)JUS (x20) CPP (x13)

JUS (x13)CPP (x7)JUS (x7)

CPP (x6)JUS (x6)

MSG (x339)

NDO (x328)TAS (x101)

PNA (x134)TAS (x26)

CPP (x169)JUS (x169)

NDO (x222)TAS (x68)

NDO (x1955)

MSG (x206)

MSG (x415)

MSG (x358)

MSG (x412)

MSG (x261)TAS (x51)

NDO (x68) NDO (x43)

NDO (x76)

NDO (x76)

NDO (x315)TAS (x219)

LMR (x630)

PNA (x435)

MSG (x1452)

CPP (x224)JUS (x224)

EIV (x70)

EIV (x226)

EIV (x86)

ACO (x99)

ACO (x36)

ACO (x24)

ACO (x45)

ACO (x54)

CPP (x20)JUS (x20)CPP (x13)

JUS (x13)CPP (x13)JUS (x13)

CPP (x13)JUS (x13)

CPP (x5)JUS (x5)

CPP (x17)JUS (x17) CPP (x13)

JUS (x13)CPP (x7)JUS (x7)

CPP (x6)JUS (x6)

CPP (x20)JUS (x20)

CPP (x13)JUS (x13)

CPP (x13)JUS (x13)

CPP (x13)JUS (x13)

CPP (x5)JUS (x5)

CPP (x16)JUS (x16) CPP (x13)

JUS (x13)CPP (x7)JUS (x7)

CPP (x6)JUS (x6)

PNA (x3)PNA (x3) PNA (x3)

NDO (x185)TAS (x94)

414.95

QPA (x1)

BPD (x3)

BPD (x3)

BPD (x2)

BPD (x4)

BPD (x3)

BPD (x1)

BPD (x3)

BPD (x5)

BPD (x5) BPD (x3)

QPA (x5)

BPD (x8)

UPA (x5)

UPA (x5)

UPA (x5)

UPA (x5)

BPD (x3)

UPA (x10)

UPA (x1)

EIV (x198)

EIV (x86)

EIV (x141)

CES (x41)

PQU (x10)

420900Surface Level

RAINGARDEN- To Civil Engineers specification

RAINGARDEN- To Civil Engineers specification

RAINGARDEN- To Civil Engineers specification

RAINGARDEN- To Civil Engineers specification

TJA (x78)

M O W NL A W N

Elms Trees

1:35Slope falls 2m x 70m

UP

UP

UP

UP

M

O

W

N

L

A

W

N

M O W NL A W N

M O W NL A W N

M O W NL A W N

Water Tank

1:20Slope falls 1.25m over 26m

1:400Slope falls 0.1m over 41m

HEAVY VEHICLE ACCESS

BATTER

R O U G HL A W N

1:16

RAM

P

UP

GAS TANK2 X 7000L

HEAVY VEHICLE ACCESS

CARPARK

P O O L

1:16

WATER TANK

418000Surface Level

417900Surface Level

417500Surface Level

423000Surface Level

421000Surface Level

4230

00S

urfa

ce L

evel

419850Surface Level

418250Surface Level

417100Surface Level

421000Surface Level

421040Surface Level

417590Surface Level

417000Surface Level

416500Surface Level

416000Surface Level

415500Surface Level

414500Surface Level

414300Surface Level

412500Surface Level

410600Surface Level

415250Surface Level

416000Surface Level

415000Surface Level

414500Surface Level

416000Surface Level

415000Surface Level

415370Surface Level

413500Surface Level

414750Surface Level

416000Surface Level

414650Surface Level

415000Surface Level

419000Surface Level 418000

Surface Level417000

Surface Level416000

Surface Level421000

Surface Level420000

Surface Level422000

Surface Level423000

Surface Level

B A T T E R

416915Surface Level

417285Surface Level

417100Surface Level

417200Surface Level

Low Garden Bed- Planting TBC by Council

Low Garden Bed- Planting TBC by Council

Concrete slab for GAS TANK- to Engineers specs- dimensions TBC

P L A N T E D B A T T E R

RAMP

GREASE TRAP- Refer HYD ENG DWGS

SUBSTATION

BINS

423570Surface Level

420960Surface Level

GA

TE

B A T T E R

Cut outs in paving- 1m diam- Planting around tree base

416390Surface Level

417920Surface Level

417800Surface Level

200mm x 200mm cut outs in paving- base of each post, front & back- creeper to grow up

BATTER AROUND COURT EDGES AS REQUIRED

412500Surface Level

411300Surface Level

417000Surface Level

413500Surface Level

WATER TANK

421040Surface Level

420860Surface Level

419500Surface Level

419000Surface Level

417000Surface Level

412000Surface Level

CHAPEL- To Architects Design

Low Garden Bed- Planting TBC by Council

UP

UP421540

Surface Level

420940Surface Level

Raised Planter - to Architects spec

Raised Planter - to Architects spec

Retaining Wall - To Architects specBalustrade

- Timber Frame & Stainless wire- See elevations

Cut Across corner- To Allow Council foot path to be reinstated

Sleeper Retaining Wall- Painted Dulux "NAMADJI"- See elevation

1:26Slope falls 0.5m over 13m

418417

416

416.200

415

414

413

412

B A T T E R

419199Surface Level

414775Surface Level

411250Surface Level

411250Surface Level

414775Surface Level

418725Surface Level

417990Surface Level

417990Surface Level

418530Surface Level

420450Surface Level

420450Surface Level

419900Surface Level

418530Surface Level

420950Surface Level

421430Surface Level

421430Surface Level

421761Surface Level

PLANT SCHEDULE

SYM Botanical Name Common Name Mat. Height Mat. Spread Spacing Pot Size Quantity

Trees

BPD Betula pendula 'Dalecarlica' Silver Birch 11m 6m As plan 30cm 43

CES Cedrela sinensis Chinese Toon Tree 8m 3.5m As plan 14cm 41

QPA Quercus palustris Pin Oak 18m 10m As plan 30cm 6

UPA Ulmus parvifolia Chinese Or Lacebark Elm 10 - 15m 10 - 15m As Plan 30cm 31

Shrubs

EIV Escallonia iveyii White Escallonia 3m 3m 750mm Tube 1305

NDO Nandina domestica Sacred Bamboo 2m 0.8m 500mm Tube 3325

Perennials

NPW Narcissus 'Paper White' White Jonquils 0.5m 0.3m As plan Bulbs 6890

Strap Leaf Plants & Grasses

LMR Liriope muscari 'Royal Purple' Purple Turf Lily 0.3m 0.4m 300mm Tube 630

MSG Miscanthus sinensis 'Gracillimus' Eulalia 1.2 - 2.1m 0.9 - 1.2m 400mm Tube 3918

PNA Pennisetum 'Nafray' Fountain Grass 0.6m 0.6m Tube 787

Ground Covers

ACO Aptenia cordifolia Baby sun rose 0.3m 0.4m 300mm 14cm 325

TAS Trachelospermum asiaticum Creeping Star Jasmine 0.3m 1.2m 500mm Tube 640

Climbers

PQU Parthenocissus quinquefolia Virginian Creeper Structure Size Structure Size Up Wire 14cm 10

TJA Trachelospermum jasminoides Chinese Star Jasmine 8.0m 0.3m Structure Size Tube 78

Aquatic Plants

CPP Carex appressa Tall Sedge 0.9 - 1.5m 0.3 - 0.6m As plan Tube 716

JUS Juncus usitatus Common Rush 0.9 - 1.5m 0.6 - 0.9m As Plan Tube 716

(E) Existing

(T) Transplant

Notes

Plant pot sizes and numbers will be determined by stock availability at the time of installation.

Spacing is indication only. Numbers to be spread evenly over the area indicated on the plan.

* Plants supplied to be hedged should be full and bushy. All to be of similar shape and size

** Trees supplied in 30cm pots should be a minimum of 1.5m high from top of pot and single trunked.

All should be of similar shape and size. Double staking may be required.

*** Trees supplied as Advanced should be a minimum of 2.5m plus high from top of pot and single trunked.

All should be of similar shape and size. Double staking may be required.

SITE SPECIFICATION

Sleeper Walls

Sleeper walling is to be constructed with galvanised steel H beam posts. Treated Pine sleepers set between posts to

required height. Ensure footings and walling are constructed to structural engineers specifications and to Australian Standards.

Planting

Planting shall be carried out using accepted horticultural practices with all plants conforming to the species, size and quantities

indicated on the Landscape Plan and Plant Schedule. Plants shall be thoroughly soaked through immersion in water prior to

planting and if the planting soil is very dry then the planting hole is also to be filled with water and allowed to drain completely.

The root-ball of semi-advanced trees is to be well irrigated rather than immersed.

All plants shall be appropriately hardened off in the nursery. Use plants with the following characteristics: Large healthy root

systems with no evidence of root curl or pot bound restriction or damage, vigorous, well established, free from disease and

pests and of good form, consistent with the species or variety, hardened off – not soft or forced. Plants that do not meet these

requirements will be rejected.

Planting holes for shrubs and groundcovers are to be of minimum size 75mm larger than the planting pot in all directions.

Semi-advanced tree planting holes are to be the same depth as the root-ball and 2-3 times its diameter, with the top of the root-

ball being at grade. Planting holes are not to be excavated using an auger unless the edges of the hole are later broken up

using a spade or similar. The use of augers can smooth the side of the hole and lead to root girdling. A 75mm high berm is to

be constructed at edge of root-ball to hold water.

All plants are to be thoroughly watered after planting and slow release fertiliser added at the quantities specified by the

manufacturer.

SITE SPECIFICATION

Mulching

Organic mulch is to be supplied to all garden beds and is to be of chipped or shredded vegetable material with 80% of particles

in the size range 25 to 50mm in plan and 5 to 10mm in thickness. No particles are to exceed 75mm in plan. Mulch shall be free

of deleterious and extraneous matter such as soil, weeds and sticks. Mulch is to be stockpiled and thoroughly weathered prior

to delivery.

This mulch shall be laid to a minimum depth of 100mm and is to be sloped towards plant stems and kept 100mm back from the

steams of all plants to prevent collar rot.

Irrigation

An approved Netafim irrigation system is to be supplied to all garden beds and planter boxes. It is the responsibility of the

contractor to ensure that all irrigation meets Netafim specifications. This system is to be comprised of drip irrigation to all

garden beds and planter boxes including a rain-shut off device and timer.

Plant Establishment Period

There shall be a 13 week plant Establishment Period following the approval of Practical Completion by the responsible

authority. During this period the landscape contractor shall make good all defects in his / her scope of works.

Maintenance and Establishment means the care and maintenance of the contract area by accepted horticultural practices,

as well as rectifying any defects that become apparent in the work under normal use. This shall include, but shall not

be limited to watering, fertilising, weeding, pruning, pest and disease control, cultivation, re-staking and replacement

of any plants that fail or are damaged with plants of the same species and size.

PLANNING SPECIFICATION LISTS

NOT FOR CONSTRUCTION

Lighting - Ground Mount LED Luminaire- from garden spike

Lighting - 'HANGING LIGHTS' - from tree

Lighting - Recessed Bridge Rectangular Led

Lighting - Ground Mount 2LED Luminaire- from garden spike

Lighting - Car Park - P1

Lighting - Car Park - P1

SURFACES

Regular Coloured Concrete - Colour TBC

Pool

NOTES- All measurements must to be checked and verified on site.- Lighting shown for information only.- For further information, these drawing are to be read in conjunction with AECOM Hydraulic & Fire Engineers and Meinhart Civil Engineers design documentation.

Lawn - fine mown

Asphalt Heavy Vehicle Access - Car Park

Asphalt - Car Park & Hotel Entrance

Pebbles beds - Rain garden river pebbles

Tree Grate - Water drainage

Lawn - rough mown

Garden beds - '5 way blend' with existing soil

Retaining wall - Treated Pine Timber Sleepers

Compact Gravel - Class 4 Brown 5mm - DustCrushed Aggregate with bonding agent

Steps - 'Myrtle' 600x300x35mm Bullnose

Hardstand Coloured Concrete - Colour TBC

Crazy Paving - Kanmantoo Bluestone

UP

Plain Concrete - Colour TBC

Paving - Bluestone 100x100mm grid- tactile treads

Tactile Treads

SITE SPECIFICATION

Sleeper Walls

Sleeper walling is to be constructed with galvanised steel H beam posts. Treated Pine sleepers set between posts to

required height. Ensure footings and walling are constructed to structural engineers specifications and to Australian Standards.

Planting

Planting shall be carried out using accepted horticultural practices with all plants conforming to the species, size and quantities

indicated on the Landscape Plan and Plant Schedule. Plants shall be thoroughly soaked through immersion in water prior to

planting and if the planting soil is very dry then the planting hole is also to be filled with water and allowed to drain completely.

The root-ball of semi-advanced trees is to be well irrigated rather than immersed.

All plants shall be appropriately hardened off in the nursery. Use plants with the following characteristics: Large healthy root

systems with no evidence of root curl or pot bound restriction or damage, vigorous, well established, free from disease and

pests and of good form, consistent with the species or variety, hardened off – not soft or forced. Plants that do not meet these

requirements will be rejected.

Planting holes for shrubs and groundcovers are to be of minimum size 75mm larger than the planting pot in all directions.

Semi-advanced tree planting holes are to be the same depth as the root-ball and 2-3 times its diameter, with the top of the root-

ball being at grade. Planting holes are not to be excavated using an auger unless the edges of the hole are later broken up

using a spade or similar. The use of augers can smooth the side of the hole and lead to root girdling. A 75mm high berm is to

be constructed at edge of root-ball to hold water.

All plants are to be thoroughly watered after planting and slow release fertiliser added at the quantities specified by the

manufacturer.

SITE SPECIFICATION

Mulching

Organic mulch is to be supplied to all garden beds and is to be of chipped or shredded vegetable material with 80% of particles

in the size range 25 to 50mm in plan and 5 to 10mm in thickness. No particles are to exceed 75mm in plan. Mulch shall be free

of deleterious and extraneous matter such as soil, weeds and sticks. Mulch is to be stockpiled and thoroughly weathered prior

to delivery.

This mulch shall be laid to a minimum depth of 100mm and is to be sloped towards plant stems and kept 100mm back from the

steams of all plants to prevent collar rot.

Irrigation

An approved Netafim irrigation system is to be supplied to all garden beds and planter boxes. It is the responsibility of the

contractor to ensure that all irrigation meets Netafim specifications. This system is to be comprised of drip irrigation to all

garden beds and planter boxes including a rain-shut off device and timer.

Plant Establishment Period

There shall be a 13 week plant Establishment Period following the approval of Practical Completion by the responsible

authority. During this period the landscape contractor shall make good all defects in his / her scope of works.

Maintenance and Establishment means the care and maintenance of the contract area by accepted horticultural practices,

as well as rectifying any defects that become apparent in the work under normal use. This shall include, but shall not

be limited to watering, fertilising, weeding, pruning, pest and disease control, cultivation, re-staking and replacement

of any plants that fail or are damaged with plants of the same species and size.