1 08/2011 Putting Knowledge to Work Design of a mobile, safety-critical in-hospital glucose management system Bernhard HÖLL a, , Stephan SPAT a , Johannes PLANK b , Lukas SCHAUPP b , Katharina NEUBAUER b , Peter BECK a , Franco CHIARUGI c , Vasilis KONTOGIANNIS c , Thomas R. Pieber b , Andreas HOLZINGER d a JOANNEUM RESEARCH Forschungsges.m.b.H., Institute for Biomedicine and Health Sciences, Graz, Austria b Medical University of Graz, Department of Internal Medicine, Division of Endocrinology and Nuclear Medicine, Graz, Austria c Foundation for Research and Technology - Hellas, Institute of Computer Science, Computational Medicine Laboratory, Heraklion, Crete, Greece d Medical University of Graz, Institute of Medical Informatics, Research Unit Human-Computer Interaction, Graz, Austria

Upload: others

Post on 17-Apr-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Design of a mobile, safety-critical in-hospital glucose

1

0

8/20

11

Putting Knowledge to Work

Design of a mobile, safety-critical in-hospital glucose management system

Bernhard HÖLLa,, Stephan SPATa, Johannes PLANKb, Lukas SCHAUPPb, Katharina NEUBAUERb, Peter BECKa, Franco CHIARUGIc,

Vasilis KONTOGIANNISc, Thomas R. Pieberb, Andreas HOLZINGERd

a JOANNEUM RESEARCH Forschungsges.m.b.H., Institute for Biomedicine and Health Sciences, Graz, Austria

b Medical University of Graz, Department of Internal Medicine, Division of Endocrinology and Nuclear Medicine, Graz, Austria

c Foundation for Research and Technology - Hellas, Institute of Computer Science, Computational Medicine Laboratory, Heraklion, Crete, Greece

d Medical University of Graz, Institute of Medical Informatics, Research Unit Human-Computer Interaction, Graz, Austria

Page 2: Design of a mobile, safety-critical in-hospital glucose

2

0

8/20

11

Putting Knowledge to Work

Motivation

—  in-patient glycemic control of acute diseased patients with diabetes is often considered secondary in importance

—  in-patient hyperglycaemia important marker of poor clinical outcome and mortality among diabetic patients

—  treatment of diabetes and hyperglycaemia results in reduced mortality and morbidity [1]

à patients suffering from diabetes require continuous glycemic control during in-patient stays including close monitoring of blood glucose and determination of suitable treatment strategies

[1] CLEMENT, S., BRAITHWAITE, S. S., MAGEE, M. F., AHMANN, A., SMITH, E. P., SCHAFER, R. G. & HIRSCH, I. B., (2004) Management of Diabetes and Hyperglycemia in Hospitals. Diabetes Care, 27, 2, 553-591.

Page 3: Design of a mobile, safety-critical in-hospital glucose

3

0

8/20

11

Putting Knowledge to Work

Current situation at ward

Patient A Diabetes type 2 nurse

Patient B No Diabetes

specialist physician at ward round

ward physician

night shift

Page 4: Design of a mobile, safety-critical in-hospital glucose

4

0

8/20

11

Putting Knowledge to Work

General requirements —  Execution of the application via a mobile device to perform activities

directly at the point of care (patients bed) —  No data storage on the mobile device. Wireless communication via web

services to an external server, on which the data should be placed —  Distributed/time-independend access to data from any place in the hospital —  Documentation and visualization of the most important parameters relating

to diabetes care on the mobile device —  Automated decision support for insulin dosage [2],[3] —  Reminder for open tasks through an active task management —  Avoidance of manual (and multiple) inputs. A connection to the hospital and

laboratory information system is necessary in order to transfer administrative data automatically à integration of system

[2] UMPIERRREZ, G. E., HOR, T., SMILEY, D., TEMPONI, A., UMPIEREZ, D., CERON, M., MUNOZ, C., NEWTON, C., PENG, L. & BALDWIN, D. (2009) Comparison of Inpatient Insulin Regimens with Detemir plus Aspart Versus Neutral Protamine Hagedorn plus Regular in Medical Patients with Type 2 Diabetes. Journal of Clinical Endocrinology Metabolism, 94, 2, 564-569.

[3] UMPIERREZ, G. E., SMILEY, D., ZISMANN, A., PRIETO, L. M., PALACIO, A., CERON, M., PUIG, A. & MEJIA, R. (2007) Randomized Study of Basal-Bolus Insulin Therapy in the Inpatient Management of Patients with Type 2 Diabetes (RABBIT 2 Trial). Diabetes Care, 30, 9, 2181-2186.

Page 5: Design of a mobile, safety-critical in-hospital glucose

5

0

8/20

11

Putting Knowledge to Work

Methods —  interdisciplinary team (physicians, nurses, technicians, IT-Experts) —  user-centred design approach —  mock-ups and early prototypes as trigger for clinical personnel —  iterative approach —  continuous risk management —  usability testing (Thinking Aloud)

Page 6: Design of a mobile, safety-critical in-hospital glucose

6

0

8/20

11

Putting Knowledge to Work

Results Evolution of Solution – Excel prototype

Page 7: Design of a mobile, safety-critical in-hospital glucose

7

0

8/20

11

Putting Knowledge to Work

Results Evolution of Solution – 1st usability study

Evolution of Solution – Mock-up for mobile application

Page 8: Design of a mobile, safety-critical in-hospital glucose

8

0

8/20

11

Putting Knowledge to Work

Results Evolution of Solution – prototype implementation

Page 9: Design of a mobile, safety-critical in-hospital glucose

9

0

8/20

11

Putting Knowledge to Work

Results Evolution of Solution – prototype implementation

Page 10: Design of a mobile, safety-critical in-hospital glucose

10

0

8/20

11

Putting Knowledge to Work

Results Evolution of Solution – prototype implementation

Page 11: Design of a mobile, safety-critical in-hospital glucose

11

0

8/20

11

Putting Knowledge to Work

Conclusion —  Physicians and nurses have been involved in each design step

àend-users have determined main parts of functionality and design —  Use of triggers (mock-ups/prototypes)

à end-users got a better idea of design possibilities/functionality à base for decisions and compromises between users à base for further development and/or changes

—  Clinicians/nurses and engineers have very different points of view concerning software àClinicians/nurses: only basic functionality; no manual input; easy but well sophisticated user interface, tailored to current workflow patterns; system integration à Technicians/IT-Experts: focus on gathering as much functionality as possible

—  User-centred approach as important precondition to meet the requirements of medical device directive for software (IEC 62366 standard)

Page 12: Design of a mobile, safety-critical in-hospital glucose

12

0

8/20

11

Putting Knowledge to Work

Outlook —  on-going: clinical study of decision support for insulin

dosage on paper at Medical University of Graz (MUG) —  finishing of implementation work

—  Integration of security WSS, Entity Management

—  Interfaces to HIS/LIS —  2nd usability study —  clinical study with software solution at

department of Endocrinology at MUG

Page 13: Design of a mobile, safety-critical in-hospital glucose

13

0

8/20

11

Putting Knowledge to Work

Thank you!

Contact details è  Stephan Spat / Bernhard Höll è  JOANNEUM RESEARCH Forschungsgesellschaft mbH,

Institute for Biomedicine and Health Sciences , Elisabethstraße 11a, 8010 Graz, Austria

è  Phone: +43 (0) 316 876 2157 è  E-mail: [email protected], [email protected] è  Homepage: http://www.joanneum.at/

Acknowledgements. This work was partly funded by the E. C. under the 7th Framework Program in the area of Personal Health Systems under Grant Agreement no. 248590. Homepage: http://www.reactionproject.eu/news.php