SUBSEA TREE DESIGN DATA (Includes Wellhead/Downho le) No. System Design Requirements Comments 1 Functionality - Open & Shutdown the Production - Control & Monitor the Flow (Speed, Pressure, Temperature, Sand, etc) - Provide Interfaces to Flowline - Inject Chemical Fluids into the Well and/or Flowlines  As minimum functionality. Number of Subsea Tree 5 Fixed. Tree Type Vertical (Conventional) Fixed. Design Life 30 years Pressure Rating 10,000 Psi +1,000 Psi as maximum SITHP. Min/Max Operating Temperatures -29˚C to 136˚C The materials shall be charpy tested to -46˚C. Maximum Flowrate - 185 MMSCFD for long term - 250 MMSCFD for less than 1-month - Maximum Flow Velocity 50m/sec at 250 MMSCFD - Injection Point / Well - Tree : 2 x MEG - Wellhead : Not required Fixed. Smart Well Function No - Fiber Optic Requirements No - Sensors / Well - Tree : 4 x Pressure and Temperature; 1 x Delta Pressure across the Choke; 1 x Acoustic Sand Detector; 1 x Erosion Probe - Wellhead : 1set of DHPTG; Dual PT (Pressure-Temperature) Sensors Fixed. Multiphase Flowmeter No - Number of SCSSV / Well 1 Production tubing configured to enable installation of SCSSV bu wire-line, Fixed. Number of SCSSV Control Line / Well 2 Fixed.  Annulus Vent Yes - Interfaces to Flowline Yes - Tree Connector Yes - TH System Yes - ROV Interface Yes - Control Junction Yes For umbilical control hook- up, Fixed. Design Water Depth -1000m - Other Design Materials Carbon Steel (anti-corrosive overlay) - Rigidity & Reliability Yes - Operation Cycle Minimized May require intervention plan. Operating Forces / Torque Maximum 50 lb-ft - Design Loads ? -  Valve Actuator Yes -

Upload: martinus-luckyanto

Post on 03-Apr-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Design Requirement of Vxt1

7/29/2019 Design Requirement of Vxt1

http://slidepdf.com/reader/full/design-requirement-of-vxt1 1/3

SUBSEA TREE DESIGN DATA (Includes Wellhead/Downhole)

No. System Design Requirements Comments

1 Functionality

- Open & Shutdown the Production

- Control & Monitor the Flow (Speed,Pressure, Temperature, Sand, etc)

- Provide Interfaces to Flowline- Inject Chemical Fluids into the Well

and/or Flowlines

As minimum functionality.

Number of Subsea Tree 5 Fixed.

Tree Type Vertical (Conventional) Fixed.

Design Life 30 years

Pressure Rating 10,000 Psi+1,000 Psi as maximumSITHP.

Min/Max OperatingTemperatures

-29˚C to 136˚C The materials shall becharpy tested to -46˚C.

Maximum Flowrate- 185 MMSCFD for long term- 250 MMSCFD for less than 1-month

-

Maximum Flow Velocity 50m/sec at 250 MMSCFD -

Injection Point / Well- Tree : 2 x MEG- Wellhead : Not required

Fixed.

Smart Well Function No -

Fiber Optic Requirements No -

Sensors / Well

- Tree : 4 x Pressure andTemperature; 1 x Delta Pressureacross the Choke; 1 x AcousticSand Detector; 1 x Erosion Probe

- Wellhead : 1set of DHPTG; Dual PT(Pressure-Temperature) Sensors

Fixed.

Multiphase Flowmeter No -

Number of SCSSV / Well 1

Production tubingconfigured to enableinstallation of SCSSV buwire-line, Fixed.

Number of SCSSV ControlLine / Well

2 Fixed.

Annulus Vent Yes -

Interfaces to Flowline Yes -

Tree Connector Yes -

TH System Yes -

ROV Interface Yes -

Control Junction YesFor umbilical control hook-up, Fixed.

Design Water Depth -1000m -

Other Design

Materials Carbon Steel (anti-corrosive overlay) -

Rigidity & Reliability Yes -

Operation Cycle MinimizedMay require interventionplan.

Operating Forces / Torque Maximum 50 lb-ft -

Design Loads ? -

Valve Actuator Yes -

Page 2: Design Requirement of Vxt1

7/29/2019 Design Requirement of Vxt1

http://slidepdf.com/reader/full/design-requirement-of-vxt1 2/3

DBB Valve System Yes -

U-Value 0,7 -

Tree Piping Refer to ISO 13628-4 -

Tree Cap Required -Tree Guide Frames Required -

TFL Wye Spool Required -

Tree Running Tools Required -

Retrievable Choke Yes -

Sealing System Metal to Metal -

Storage TemperatureRange

-10˚C to 70˚C -

Tree Guide Frame YesProviding guidance forinstallation and intervention.

MechanicalPerformance

Maximum allowablemate/de-mate force

500N (112lbf)

Minimum mate/de-matecycle life

100 mates in turbid sand, salt andwater

Connector Shear LoadResistance

Maximum 6.75 metric tons

Hydrocarbon SealConfiguration

Seals of dissimilar designs andmaterials are required for all pressureboundaries/barriers. Metal seals arepreferred for all primary seals.

Misalignment EngagementConnector Inter-Changeability

Connectors shall be interchangeable(inter-mateable) between matinghalves and shall not be matched sets.

Debris

The wetmate interface shall bedesigned to be tolerant of debrispresent in the interface during normalmating operations.

Electrical Performance

Maximum Working Voltage 600 VDC

Test Voltage 2400 VDC

Maximum Working Current 5.0 AmpMaximum ContactResistance

˂30 ohm with 2.0 A load (excludingtest leads) per contact pair.

Insulation Resistance

- Qualification = 10 GΩ @1000 VDC

(1minute duration)- During FAT = 10 GΩ @500 VDC

(1minute duration)

Page 3: Design Requirement of Vxt1

7/29/2019 Design Requirement of Vxt1

http://slidepdf.com/reader/full/design-requirement-of-vxt1 3/3