determination of additives in polymeric material by … pellet(around 0.1 mg) and the analysis...

Furukawa Review, No. 45 2014 22 Polymeric materials include various additives according to the demand characteristics required, for instance, the improvement of the formability, the physical property, the functionality or the durability. It is important to conduct the qualitative and the quantitative analysis of these additives for the purposes of the product design and the quality control. On the other hand, the demand characteristics of polymeric materials have become more sophisticated and complicated in the recent years, leading to the improvement and the development of additives, increas- ing the number of cases where the conventional technol- ogy is not sufficient for the analysis. For example, the pyrolysis-GC/MS analysis is a very useful method for additives in polymeric materials, because pretreatment like the solvent extraction is not necessary and enable the direct measurement of a small sample. However, it has some difficulties in identifying the original additives according to decomposing of the additives on pyrolysis condition, or masking the additive component from the decomposed materials by a matrix polymer. When using pyrolysis-GC(Gas Chromatograph)/MS (Mass Spectrometer) /FPD (Flame Photometric Detector) system with a purged splitter installed at the end of the column during the analysis of additives in polymeric materials, we can enable the simultaneous detection through MS and FPD. Since we were able to identify more easily additives which included phosphorus and sulfur in their structure, we would like to introduce the analysis in detail 1) . We analyzed an antistatic polycarbonate pellet in the mar- ketplace to identify the additives in the polymer by the conventional method of infrared spectrometry and the reactive pyrolysis-GC/MS. 2.1 Infrared Spectrometry The infrared absorption spectrum measured by the atten- uated total reflection (ATR) method using Fourier- transform infrared spectrometer (Nicolet Magna 550) with a single bounce ATR attachment (SensIR Technologies DuraScope) The result is shown in Figure 1 and there is no differ- ence between the antistatic polycarbonate and the refer- ence polycarbonate. We could not identify absorption spectrum derived from an antistatic agent. Determination of Additives in Polymeric Material by Pyrolysis-GC/MS/FPD Analysis Kenji Iizuka* Polymeric materials include various additives according to the demand character- istics required. It is important to conduct the qualitative and the quantitative analy- sis of these additives for the purposes of the product design and the quality control. On the other hand, the demand characteristics of polymeric materials have become more sophisticated and complicated in recent years, leading to the improvement and the development of additives, thus, increasing the number of cases where the conventional technology is not sufficient for the analy- sis. Through the usage of pyrolysis-GC (Gas Chromatograph)/MS (Mass Spectrometer) /FPD (Flame Photometric Detector) system with purged splitter installed at the end of the column during the analysis of additives in polymeric materials, which enables the simultaneous detection through MS and FPD, we were able to more easily identify the additives which included phosphorus and sulfur in their structure, as compared with the conventional pyrolysis-GC/MS method. Consideration to the determination of the precision was also given, and it was found that the results were better than those using MS detectors. ABSTRACT * Research & Development Div. Polymer Materials R&D Laboratories Polymer Materials Technology Special Issue 1. INTRODUCTION 2. ANALYSIS OF AN ANTISTATIC AGENT IN POLYCARBONATE BY THE CONVENTIONAL METHOD

Upload: dinhkhuong

Post on 15-May-2018

216 views

Category:

Documents


1 download

TRANSCRIPT

Furukawa Review, No. 45 2014 22

1. INTRODUCTION

Polymeric materials include various additives according to the demand characteristics required, for instance, the improvement of the formability, the physical property, the functionality or the durability. It is important to conduct the qualitative and the quantitative analysis of these additives for the purposes of the product design and the quality control. On the other hand, the demand characteristics of polymeric materials have become more sophisticated and complicated in the recent years, leading to the improvement and the development of additives, increas-ing the number of cases where the conventional technol-ogy is not sufficient for the analysis. For example, the pyrolysis-GC/MS analysis is a very useful method for additives in polymeric materials, because pretreatment like the solvent extraction is not necessary and enable the direct measurement of a small sample. However, it has some difficulties in identifying the original additives according to decomposing of the additives on pyrolysis condition, or masking the additive component from the decomposed materials by a matrix polymer.

When using pyrolysis-GC(Gas Chromatograph)/MS (Mass Spectrometer) /FPD (Flame Photometric Detector) system with a purged splitter installed at the end of the column during the analysis of additives in polymeric

materials, we can enable the simultaneous detection through MS and FPD. Since we were able to identify more easily additives which included phosphorus and sulfur in their structure, we would like to introduce the analysis in detail 1).

2. ANALYSIS OF AN ANTISTATIC AGENT IN POLYCARBONATE BY THE CONVEN-TIONAL METHOD

We analyzed an antistatic polycarbonate pellet in the mar-ketplace to identify the additives in the polymer by the conventional method of infrared spectrometry and the reactive pyrolysis-GC/MS.2.1 Infrared SpectrometryThe infrared absorption spectrum measured by the atten-uated total reflection (ATR) method using Fourier-transform infrared spectrometer (Nicolet Magna 550) with a single bounce ATR attachment (SensIR Technologies DuraScope)

The result is shown in Figure 1 and there is no differ-ence between the antistatic polycarbonate and the refer-ence polycarbonate. We could not identify absorption spectrum derived from an antistatic agent.

Determination of Additives in Polymeric Material by Pyrolysis-GC/MS/FPD Analysis

Kenji Iizuka*

Polymeric materials include various additives according to the demand character-istics required. It is important to conduct the qualitative and the quantitative analy-

sis of these additives for the purposes of the product design and the quality control. On the other hand, the demand characteristics of polymeric materials have become more sophisticated and complicated in recent years, leading to the improvement and the development of additives, thus, increasing the number of cases where the conventional technology is not sufficient for the analy-sis. Through the usage of pyrolysis-GC (Gas Chromatograph)/MS (Mass Spectrometer) /FPD (Flame Photometric Detector) system with purged splitter installed at the end of the column during the analysis of additives in polymeric materials, which enables the simultaneous detection through MS and FPD, we were able to more easily identify the additives which included phosphorus and sulfur in their structure, as compared with the conventional pyrolysis-GC/MS method. Consideration to the determination of the precision was also given, and it was found that the results were better than those using MS detectors.

ABSTRACT

* Research & Development Div. Polymer Materials R&D Laboratories

Polymer Materials TechnologySpecial Issue

1. INTRODUCTION

2. ANALYSIS OF AN ANTISTATIC AGENT IN POLYCARBONATE BY THE CONVENTIONAL METHOD

Furukawa Review, No. 45 2014 23

Determination of Additives in Polymeric Material by Pyrolysis-GC/MS/FPD Analysis

2.2 Reactive Pyrolysis-GC/MS AnalysisIt is difficult in general to detect or to identify components derived from additives on pyrolysis-GC/MS analysis of polymeric materials, because a lot of thermal decomposi-tion occurred from the matrix polymer masks small quan-tity of the components derived from the additives. On the other hand, additives in the polycondensation resins like polycarbonates, polyesters and polyurethanes are inclined to detect easily the component derived from the additives on reactive pyrolysis-GC/MS with hydrolysis reagents like methyl esterifying reagents. Since ester bond or urethane bond in the matrix polymer are decom-posed primarily by the reagents and the decompositions derived from the matrix polymer are only monomer deriv-atives, it is easy to identify the component derived from the additives2)-5).

We tried the pyrolysis-GC/MS analysis on the antistatic polycarbonate to identify the antistatic agent. Alkaline methylation reagent (20% Tetramethylammonium hydrox-ide methanol solution (TMAH)) was added in a powdered sample pellet(around 0.1 mg) and the analysis condition is shown in Table 1.

Total ion chromatogram(TIC) of pyrolysis-GC/MS analy-sis on the antistatic PC and the reference PC is shown Figure 2.

Bisphenol-A dimethyl ether of a monomer derivative from polycarbonate, phenol and 4-tert-Butylphenyl methyl ether of polymer end component were detected for both of the antistatic polycarbonate and the reference polycar-bonate.

With respect to the antistatic polycarbonate, Tri-butyl phosphine oxide at 17.1 min. and phosphine compound like Butyl diocthyl phosphine oxide at 24.3 min. were detected but derivatives from the surface active agent like the higher fatty acid salt generally used as an antistatic agent was not detected.

According to the result, the phosphine compound, trial-kyl phosphonium oxide, was presumed to be derived from the antistatic agent, however it was not identified whether the compound is a component of the agent or a reaction product of the antistatic agent with TMAH.

3. ANALYSIS WITH A REACTIVE PYROLY-SIS-GC/MS/FPD

3.1 ExperimentTrialkyl phosphine oxide was detected with a reactive pyrolysis-GC/MS. In order to analyze whether it was the antistatic agent itself or the reaction product of the anti-static agent with TMAH, we tried to detect the agent with a pyrolysis GC/MS without TMAH called simple pyrolysis-GC/MS, and since the agent contained phosphine, a Flame Photometric Detector (FPD), which detects phos-phine and sulfur highly selectively and sensitively, was combined to use with the pyrolysis GC/MS . This is a simultaneous analysis with pyrolysis-GC/MS/FPD6)-9). Eluted material from the GC is divided into MS detector

40

50

60

70

80

90

100

110

120

130

%Tr

ansm

ittan

ce

1000 1500 2000 3000 4000 Wavenumbers (cm-1)

Antistatic PC

Reference PC

Figure 1 Infrared spectrum of an antistatic polycarbonate resin. (Upper: Antistatic PC, Lower: Reference PC)

P C4H9

C4H9

C4H9

O P C8H17

C8H17

C4H9

O

0 5 10 15 20 25 30 35 40

Time (min)

10

20

30

40

50

60

70

80

90

100

Rel

ativ

e A

bun

dan

ce

10

20

30

40

50

60

70

80

90

100

Rel

ativ

e A

bun

dan

ce

1

3

2

2

Antistatic PC

Reference PC

Figure 2 Reactive pyrolysis-GC/MS chromatogram of antistatic polycarbonate resin.

1:4-tert-Butylphenyl methyl ether;2:Bisphenol-A dimethyl ether;3:Methyl phenyl ether

Table 1 Conditions of pyrolysis-GC/MS analysis.

Apparatus

Gas Chromatography-Mass spectrometry (GC/MS); JMS-Q1050GC of JEOL Ltd.Pyrolyzer; PY-3030D of Frontier Laboratories Ltd.

Pyrolysis temperature

400℃

ColumnUA-+5 of Frontier Laboratories Ltd.(Length: 30 m, Inner diameter: 0.25 mm, Film thickness: 0.25 µm)

GC Temperature 40℃(4 min) → 10℃ /min → 320℃(Hold)

Carrier Gas He, 1.0 ml/min. (Constant flow)

3. ANALYSIS WITH A REACTIVE PYROLYSIS-GC/MS/FPD

Furukawa Review, No. 45 2014 24

Determination of Additives in Polymeric Material by Pyrolysis-GC/MS/FPD Analysis

and FPD through the purged splitter installed at the end of the column and analyzed simultaneously.3.2 Result and DiscussionPyrolysis-GC/MS/FPD chromatogram of the antistatic polycarbonate is shown in Figure 3.

A peak at 13.6 min. of 4-tert-butylphenol based on an end group of polycarbonate and another peak at 24.0 min. of bisphenol-A were detected in the MS chromato-graph (TIC).

On the other hand, a strongly reported peak 2 at 14.6 min. in the FPD chromatogram was detected and identi-fied a Tributyl phosphine according to MS spectrum anal-ysis on a corresponding peak of TIC, as shown in Figure 4.

Peak 3 at 23.8 min. of FPD was identified Butyl-dioctyl phosphine as the identification for the peak 2.

According to these results, we presumed that the anti-static agent in the polycarbonate was quaternary phos-phonium salt, in detail tetraalkyl phosphonium salt, shown in Figure 5.

Since the tributyl phosphineoxide detected by the reac-

tive pyrolysis-GC/MS analysis was not detected by the simple pyrolysis-GC/MS analysis, we concluded that the tributyl phosphineoxide was occurred through a reaction of the quaternary phosphonium salt shown in Figure 5 or tributyl phosphine by pyrolysis of the phosphonium salt with TMAH.

A structure of the fourth alkyl group in the estimated structure of Figure 5 was unknown. In order to determine the structure, two kinds of tetra-alkyl phosphonium salt, tet-rabutyl phosphonium (manufactured by Tokyo Chemical Industry Co., Ltd.) and tributylmethyl phosphonium bis (tri-fluoromethanesulfonyl) imide (manufactured by Tokyo Chemical Industry Co., Ltd.) were checked by the pyroly-

Time (min)

Rel

ativ

e A

bso

rban

ce

4 6 8 10 12 14 16 18 20 22 24 26 28 30

10

20

30

40

50

60

70

80

90

10010

20

30

40

50

60

70

80

90

100

Rel

ativ

e A

bun

dan

ce

1

3

2

2

MS(TIC)

FPD(P)

4

3

Figure 3 Pyrolysis-GC/MS/FPD chromatograph of an antistatic polycarbonate resin.

1:4-tert-Butylphenol; 4:Bisphenol-A

MS spectrum of peak-2

20 50 80 110 140 170 200

50

0

100

50

0

100

20 50 80 110 140 170 200

Tributyl phosphine

P C H

C H

C

4 9

4 9

4 9H

2941

62

76

89

104131

173

202146

2941

62

76

89

104

131173

202146

m/Z

m/Z

Rel

ativ

e A

bun

dan

ceR

elat

ive

Ab

und

ance

Figure 4 Identification result of peak-2.

P+

C4 H9R1

C4 H9

C4 H9

X

Figure 5 Estimated structure of the antistatic agent.

R1:Alkyl group; X:Anion

Furukawa Review, No. 45 2014 25

Determination of Additives in Polymeric Material by Pyrolysis-GC/MS/FPD Analysis

sis-GC/MS/FPD analysis. The result is shown in Figure 6 and Figure 7.

We had only a peak at 15.2 min. of tributyl phosphine for tetrabutylphosphonium bromide. On the other hand, we did not detect any tributyl phosphine for tributylmeth-ylphosphonium bis (trifluoromethanesulfonyl) imide but detected at 11.1 min. methyl-dibutyl phosphine which substituted one out of three alkyl group of tributyl phos-fine in the methyl group.

In order to get a structure in which phosphine bonded with three of alkyl group having same structure as tributyl phosfine, four of alkyl group bonded with phosphine have to be of the same structure. According to the above results, we presumed that the antistatic agent in the anti-static polycarbonate was tetrabutylphosphonium salt compound.

4. QUANTATIVE ANALYSIS OF AN ANTI-STATIC AGENT WITH A PYROLYSIS GC/MS/FPD

It is known to detect phosphorus additives (Phosphorus antistatic agent) highly selectively and sensitively by the simultaneous analysis with pyrolysis-GC/MS/FPD and to identify a structure of the additives. We further tried a quantitative analysis of the structure identified additives in the polymer because it is important to know the content of the additives from the product design and the quality control perspective.

Since phosphorous compounds are detected highly selectively and sensitively by the simultaneous Pyrolysis-GC/MS/FPD analysis, the quantitative analysis of the tet-ra-alkylphosphonium salt compound was tried.4.1 ExperimentTetrabutylphosphonium bromide was selected as a model compound and its methanol solution with a range of con-centration were prepared. The different concentrated methanol solution of 1 μL was obtained in a sample cup and analyzed with the pyrolysis-GC/MS/FPD.

With respect to the quantitative evaluation, we made a linearity test for a calibration curve of peak area of tributyl phosphine to sample mass between FPD and MS detec-tor.

An area peak of MS chromatogram that is a fragment of m/z=76 which is the highest intensity of MS spectrum is used for the calibration curve of the MS detector. 4.2 Result and DiscussionFigure 8 a) and b) show the calibration curve of the FPD and the MS detector respectively. Correlation coefficient (R2) of the calibration curve for the FPD data was 0.9990 indicating a very good linearity. However, the correlation coefficient for the MS detector calibration curve was 0.9984 and it was a worse linearity than FPD.

According to the result, we understood that FPD had an advantage on the quantitative measurement for the tetra-butyl phosphonium salt compound.

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30

Time (min)

30405060708090

Rel

ativ

e A

bso

rban

ce

30405060708090

Rel

ativ

e A

bun

dan

ce

20 40 60 80 100 120 140 160 180 200 220 240

m/z

0

20

40

60

80

100

Rel

ativ

e A

bun

dan

ce

76

62

1734129 104 131 20289 146

1

1

MS spectrum of peak-1 P C4H9

C4H9

C4H9

MS(TIC)

FPD(P)

Figure 6 Analytical result of the tetrabutylphosphonium bromide with pyrolysis-GC/MS/FPD.

0

50

100

50 100 150 200 250 300 350 400m/z

29 41

62

76

89 103 131 160

Rel

ativ

e A

bso

rban

ce

020406080

100

Rel

ativ

e A

bso

rban

ce

020406080

100

Time (min)6 8 10 12 14 16 18 20 22 24 26 28 30

1

1

MS spectrum of peak-1P C4H9

C4H9

CH3

MS(TIC)

FPD(P)

Rel

ativ

e A

bun

dan

ce

Figure 7 Analytical result of the tributylmethlphosphonium bis(trifluoromethanesulfonyl) imide with pyrolysis-GC/MS/FPD.

4. QUANTATIVE ANALYSIS OF AN ANTI-STATIC AGENT WITH A PYROLYSIS GC/MS/FPD

Furukawa Review, No. 45 2014 26

Determination of Additives in Polymeric Material by Pyrolysis-GC/MS/FPD Analysis

5. ANALYSIS OF THE CURING AGENT IN A VULCANIZED RUBBER

5.1 ExperimentWe investigated to identify a curing agent in a vulcanized rubber by the pyrolysis-GC/MS/FPD analysis.

Analysis condition for the vulcanized rubber was the same as the antistatic agent analysis except that the FPD setting was changed to detect the sulfuric compound, and pyrolysis condition was also changed.5.2 Result and DiscussionFigure 9 shows a result of the thermal desorption-GC/MS/FPD at 300℃ for the sample rubber. According to the data for the MS detector, α-methyl styrene, acetophe-none and α-cumyl alcohol were detected from 8 min. to 10 min. which were decomposed residue of dicumyl per-oxide. This result would suggest the rubber to be vulca-nized using peroxide.

However peak 1 at 0.9 min. and peak 2 at 2.3 min. were detected and the MS spectrum corresponding to these two peaks identified methyl mercaptan for peak 1 and dimethyl sulfide for peak 2.

Thermal residue of the rubber at 300℃ was pyrolyzed at 600℃ and analyzed with pyrolysis GC/MS/FPD. The result is shown in Figure 10 and sulfur dioxide at 1.1 min. and another two of peaks near 9.6 min. were detected.

We analyzed the 9.6 min. peak in detail with the MS spectrum and identified 2,5-cyclopenta[2,3-b]thiophene with a molecular weight of 122.

y = 108588x -4287.5

R² = 0.9990

0

50000

100000

150000

0.00 0.50 1.00 1.50 2.00 2.50 3.00

200000

250000

300000

Pea

k ar

ea

Amount(µg)

a)FPD

FPD

0.00 0.50 1.00 1.50 2.00 2.50 3.00

y = 383551x -26773

R² = 0.9984

0

100000

200000

300000

400000

500000

600000

700000

800000

900000

1000000

Pea

k ar

ea

Amount(µg)

b)MS(m/z=76)

MS

Figure 8 Quantitative accuracy of the tetrabutylphosphonium bromide by pyrolysis-GC/MS/FPD analysis.

0 5 10 15 20 25 30 35 40Time (min)

10

20

30

40

50

60

70

80

90

100

Rel

ativ

e A

bso

rban

ce

10

20

30

40

50

60

70

80

90

100

Rel

ativ

e A

bun

dan

ce

1

1

3

2

4

5

MS(TIC)

FPD(S)

Figure 9 Result of the thermal desorption-GC/MS/FPD analysis for the vulcanized rubber.

1:Methyl mercaptan; 2:Dimethyl disulfide; 3:α-Methyl styrene; 4:Acetophenone; 5:α-Cumyl alcohol

Figure 10 Result of the thermal desorption-GC/MS/FPD analysis for the vulcanized rubber.

1:Sulfur dioxide; 2:2,4-Cyclopenta [2,3-b] thiophene;3:2,5-Cyclopenta [2,3-b] thiophene

0 5 10 15 20 25 30 35 40

Time (min)

20

40

60

80

100

Rel

ativ

e A

bso

rban

ce

20

40

60

80

100

Rel

ativ

e A

bun

dan

ce

20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

m/z

20

40

60

80

100

Rel

ativ

e A

bun

dan

ce 122121

967812311750 6345 93

MS(TIC)

FPD(S)1

MS spectrum of peak-3

2, 38 9 10 11

Time (min)

2

3

Molecular Weirht=122.2Molecular Formula=C7H6S2,5-Cyclopenta [2,3-b] thiophene

S

5. ANALYSIS OF THE CURING AGENT IN A VULCANIZED RUBBER

Furukawa Review, No. 45 2014 27

Determination of Additives in Polymeric Material by Pyrolysis-GC/MS/FPD Analysis

It is reported that on pyrolyzing a sulfur vulcanized eth-ylene propylene diene rubber (EPDM) with ethylidene nor-bornene (ENB) as third component, the compound com-ponent is derived from crosslink of ENB with sulfur10)-12).

According to the above result and C-S bonded material detected on heating at 300℃, the rubber sample was pre-sumed vulcanized with inorganic sulfur.

Since sulfur curing and peroxide curing are not used in combination in general, the residue of the peroxide com-pound detected in Figure 9 was presumed a trace on contacting other peroxide cured material.

In the case of analysis for cured rubber, the convention-al analysis using only the MS detector does not identify the decomposition corresponding to the sulfur cured rub-ber because of its masking by the decomposition of the matrix polymer. However analysis in combination with the MS and the FPD detect a decomposition of sulfur cured rubber easily, rapidly and accurately.

6. CONCLUSION

We succeeded to analyze phosphorus and sulfur addi-tives in polymeric materials selectively and sensitively with pyrolysis-GC/MS/FPD.

With the pyrolysis-GC/MS/FPD, with purged splitter installed at the end of the column during analysis of addi-tives in polymeric materials, we can enable the simultane-ous detection through the MS and the FPD.

We can identify the structure of the compounds more easily than the conventional method and can make quan-titative analysis highly selectively and more accurately.

Since phosphorus and sulfur additives are used not only in the polymeric materials mentioned above but in many product of coated materials on wire & cable, rubber splicer and end splicer of power cable, and a regulation for environmental loading will be tightened, we would like to apply this analysis to material development, quality control and solution for environmental regulation and also to improve analysis technology.

REFERENCES

1) Kenji Iizuka: “Analysis of additives in polymeric materials by simul-taneous measurement with pyrolysis-GC/MS/FPD” Summary of Seventeenth Koubunnshi bunnseki touronnkai, Koubunnshi bunnseki kennkyu konndannkai (2012) Ⅳ-05 (in Japanese)

2) Frontier Laboratories Ltd. “Analysis of Terminal Groups of Polycarbonate (PC) by Reactive Pyrolysis” Technical note PYA2-001E (2001)

3) Frontier Laboratories Ltd. “Analysis of Polyethylene Terephthalate (PET) by Reactive Pyrolysis” Technical note PYA2-006E (2002)

4) Frontier Laboratories Ltd. “Analysis of Additives in Polybutylene Terephthalate (PBT)” Technical note PYA1-026E (2006)

5) Hajime Ohtani, Chuichi Wtanabe, Takayuki Masuda and Shin Tsuge “Structural Characterization of Terminal-modified and Branched Polycarbonates by Pyrolysis-Gas Chromatography in the Presence of Organic Alkali” BUNSEKI KAGAKU vol.60 (2011), 239 (in Japanese)

6) Agilent Technologies “Identifying Pesticides with Full scan, SIM, μECD and FPD from a Single Injection” Application note 5989-3299EN (2005)

7) Agilent Technologies “Screening of Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 compound DRS Database” Application note 5989-4834EN(2006)

8) Agilent Technologies “Application for Capillary Flow Technology on GC/MS analysis” Application note GCMS-200904NK-002 (2009) (in Japanese)

9) Agilent Technologies “Organophosphorus Pesticides in Apple Matrix by GC/MS/FPD using an Agilent J&W DB-35ms Ultra Inert GC Column” Application note 5990-7165EN(2012)

10) Tadaoki Okumoto, Takao Yamada, Shin Tsuge and Hajime Ohtani, Koubunshi Ronbunshu 54(1997),108 (in Japanese)

11) Tadaoki Okumoto, Takao Yamada, Shin Tsuge and Hajime Ohtani, Nihon Gomu Kyoukaishi 74(2001) 283 (in Japanese)

12) Tadaoki Okumoto Nihon Gomu Kyoukaishi 75(2002) 507 (in Japanese)

6. CONCLUSION