determination of albumin concentration by mip qcm sensor

6
Determination of Albumin Determination of Albumin Concentration by MIP QCM Concentration by MIP QCM Sensor Sensor Speaker : Speaker : Thong- Thong- Yueh Lin Yueh Lin

Upload: hadassah-nolan

Post on 31-Dec-2015

32 views

Category:

Documents


0 download

DESCRIPTION

Determination of Albumin Concentration by MIP QCM Sensor. Speaker : Thong-Yueh Lin. Loading curves of different MIP thin film. The amount of adsorption for different MIP thin films. Selectivity of DMAPMA-TMPTMA thin film. Conclusions. The protein mixture could be analyzed by HPLC. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Determination of Albumin Concentration by MIP QCM Sensor

Determination of Albumin Determination of Albumin Concentration by MIP QCM SensorConcentration by MIP QCM Sensor

Speaker : Speaker : Thong-Yueh Lin Thong-Yueh Lin

Page 2: Determination of Albumin Concentration by MIP QCM Sensor

Loading curves of different MIP thin filmLoading curves of different MIP thin film

Time (sec)

0 1000 2000 3000 4000 5000 6000 7000

Fre

qu

ence

(H

z)

-250

-200

-150

-100

-50

0

50

DMAPMA-TMPTMADMAPMA-PETTA filmDMAPMA-TEGDMA film

Page 3: Determination of Albumin Concentration by MIP QCM Sensor

Sample nameDMAPMA-TEGDMA

DMAPMA-TMPTMA

DMAPMA-PETTA

Mass of coating (g) 1.79*10-6 4.119*10-7 1.015*10-5

Adsorption amount (g)

7.10*10-8 8*10-8 5.295*10-8

Adsorption amount (g) per gram MIP

0.04 0.1942 0.005

The amount of adsorption for different The amount of adsorption for different MIP thin filmsMIP thin films

Page 4: Determination of Albumin Concentration by MIP QCM Sensor

Selectivity of DMAPMA-TMPTMA thin filmSelectivity of DMAPMA-TMPTMA thin film

Cytochrome CLysozym

eAlbumin Myoglobin

Adsorption amount mass ratio of MIP

160 1 1942 30

Adsorption amount mass ratio of non-MIP

13 1 249 86

Page 5: Determination of Albumin Concentration by MIP QCM Sensor

ConclusionsConclusions

1.1. The protein mixture could be analyzed by HPLC.The protein mixture could be analyzed by HPLC.

22.The MIP thin film coated on Au-OH electrode .The MIP thin film coated on Au-OH electrode

indicated the highest albumin adsorption.indicated the highest albumin adsorption.

3.The MIP thin film coated on Au-NH3.The MIP thin film coated on Au-NH22 electrode electrode

indicated the shortest stable time.indicated the shortest stable time.

= albumin : cytochrome c : myoglobin : lysozyme= albumin : cytochrome c : myoglobin : lysozyme

= 1.4 : 1.0 : 1.5 : 3.1= 1.4 : 1.0 : 1.5 : 3.1

22. Selectivity mole ratio of MIP. Selectivity mole ratio of MIP

= albumin : cytochrome c : myoglobin : lysozyme= albumin : cytochrome c : myoglobin : lysozyme

= 9.1 : 2.9 : 2.8 : 1= 9.1 : 2.9 : 2.8 : 1

Page 6: Determination of Albumin Concentration by MIP QCM Sensor

ConclusionsConclusions

4.The DMAPMA-TMPTMA MIP thin film 4.The DMAPMA-TMPTMA MIP thin film

showed the highest albumin adsorption showed the highest albumin adsorption

amount.amount.

5.The Selectivity of DMAPMA-TMPTMA thin 5.The Selectivity of DMAPMA-TMPTMA thin

film coated on QCM was cytochrome C: film coated on QCM was cytochrome C:

lysozyme: albumin: myoglobin= lysozyme: albumin: myoglobin=

160:1:1942:30. 160:1:1942:30.

..