device manual chapter 4.1-w optosonic 3 radio net - ista · device manual chapter 4.1-w optosonic 3...

12
L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http//www.ista.com Nur für den internen Gebrauch—For internal use only—Uniquement pour utilisation interne Device Manual Chapter 4.1-W optosonic 3 radio net

Upload: nguyentruc

Post on 07-Apr-2018

239 views

Category:

Documents


4 download

TRANSCRIPT

Device Manual

Chapter 4.1-W optosonic 3 radio net

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essenhttp//www.ista.com

Nur für den internen Gebrauch—For internal use only—Uniquement pour utilisation interne

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essen

http://www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se o

nly

— U

niq

uem

en

t p

ou

r u

tili

sat

ion

inte

rne

Table of contents

1 Device data 3

1.1 General information 3

1.2 Device display 3

1.3 Technical data 4

1.4 Main and connection dimensions 5

2 Item numbers 6

3 Installation 7

3.1 Screwed installation 7

3.2 Installation with cable ties 7

3.2.1 With mounting plate 7

3.2.2 Without mounting plate 7

3.3 Final steps 8

4 Commissioning 9

5 Exchange 10

5.1 Preparatory steps 10

5.2 For installation on mounting plate 10

5.3 If installing without mounting plate 10

6 Reading 11

6.1 Radio reading AMM 11

6.2 Radio reading Walk by 11

7 Disposal 12

Device Manual2/12 4.1-W optosonic 3 radio net

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essenhttp//www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se

on

ly —

Un

iqu

emen

t p

ou

r u

tili

sa

tio

n in

tern

e

1.1 General information

Device group Systems

Product name optosonic 3 radio net

Pictogram

Design/type Radio module for sensonic® II

Functional descriptionThe optosonic 3 radio net radio module is used to in-tegrate the sensonic® II heat meter into the ista sym-phonic sensor net radio system.

To this end, the opto head of the optosonic 3 radio net is connected to the optical interface of the sensonic® II. The optosonic 3 radio net uses this in-terface to read out the measured values of the sensonic® II. The data is saved in the module.

The optosonic 3 radio net is programmed via radio. If connected terminals have to be reprogrammed, the necessary data is transmitted to the module by radio. This then carries out the actual programming of the terminal.

Packaging Single package (1 pc. per carton)

Delivery scope ▪ optosonic 3 radio net

▪ 2 screws

1.2 Device display

Type plate

Display No display

1 Device data

Art. N° 19450S/N: XXX XXX XXXoptosonic® 3 radio net

Device Manual4.1-W optosonic 3 radio net 3/12

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essen

http://www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se o

nly

— U

niq

uem

en

t p

ou

r u

tili

sat

ion

inte

rne

1.3 Technical data

Functional principle Optical read-out of connected counters

Interfaces ▪ Output: Radio interface for the ista radio system symphonic sensor net.

▪ Input: Opto head (protected against reversed polarity), cable length 0.5 m.

Radio interface ▪ Compatible with symphonic sensor net

▪ Transmission power: < 10 mW

▪ Radio frequency: 868 MHz

▪ Duration of transmission telegram: < 10 msec/transmission

▪ Transmission rate: ~ 90 kbaud (bit/sec)

▪ Transmission method: bidirectional

▪ Data integrity: encrypted transfer

Weight 0.110 kg

Material ABS

Casing colour RAL 9002

CE label 1999/5/EC

Storage Temperature:

▪ 1st year: -25 °C to +70 °C

▪ then 0 °C to +70 °C

To be stored in a dry place

Ambient temperature 0 °C - 70 °C

Relative humidity 5 % - 95 %

Protection class IP54 acc. to EN 60529

i.e.:

▪ Protection against foreign objects: Protects against damaging amount of dust.

▪ Protects against contact: complete protection against contact.

▪ Protection against water: Protection against splash water on all sides.

Power supply 3 V lithium battery

Life cycle 10 years + 1 year reserve + 1 year storage

Technology Integrated circuit (standard)

Parameterisation data ▪ Radio network number

▪ Reference date

Device Manual4/12 4.1-W optosonic 3 radio net

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essenhttp//www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se

on

ly —

Un

iqu

emen

t p

ou

r u

tili

sa

tio

n in

tern

e

Recorded data ▪ Serial number, device ID

▪ Current date and time

▪ Next due date

▪ Commissioning date

▪ Error status

Saved consumption values Energy quantity (total volume) for

▪ 14 month-end values with date

▪ 2 reference date values with date

Reading frequency Generally 12 - 52 times per year

1.4 Main and connection dimensions

Main dimensionsH = 28 mm

W = 57 mm

L = 100 mm

Opto head dimensionsH = 15 mm

W = 64 mm

L = 19 mm

Cable length 0.5 m

Device Manual4.1-W optosonic 3 radio net 5/12

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essen

http://www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se o

nly

— U

niq

uem

en

t p

ou

r u

tili

sat

ion

inte

rne

Devices

Accessories

2 Item numbers

19450 optosonic 3 radio net

19452 optosonic/pulsonic 3 radio mounting plate

81621 Adhesive seal sensonic, grey

81627 ista meter tamper proofing, grey 10 x 40

Device Manual6/12 4.1-W optosonic 3 radio net

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essenhttp//www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se

on

ly —

Un

iqu

emen

t p

ou

r u

tili

sa

tio

n in

tern

e

3.1 Screwed installation

1. Prior to drilling, check that there are no electricity cables, gas or water pipes below the surface at the installation site.

2. Drill holes (6 mm)

with mounting plate to determine the hole spacing.3. Insert dowels.

4. Attach the mounting plate to the wall.

5. Align the mounting plate vertically

using spirit level.6. Tighten screws firmly.

Continue with final steps.

3.2 Installation with cable ties

3.2.1 With mounting plate

1. Connect cable ties to the mounting plate.

2. Fasten the mounting plate with cable ties (e.g. on a pipe).

Continue with final steps.

3.2.2 Without mounting plate

1. Connect cable ties to optosonic 3 radio net .

2. Fasten the optosonic 3 radio net with cable ties (e.g. to a pipe).

Continue with item 8.

3 Installation

1 2 3 4 5 6

1 2

1 2

Device Manual4.1-W optosonic 3 radio net 7/12

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essen

http://www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se o

nly

— U

niq

uem

en

t p

ou

r u

tili

sat

ion

inte

rne

3.3 Final steps

1. Position module on mounting plate (if installing with mount-ing plate).

2. Clean the contact surface on the sensonic II.

3. Pull off the protective foil from the rear of the opto head.

4. Glue the opto head onto the sensonic II.

5. Screw together the opto head and sensonic II.

6. Use adhesive seals to seal the opto head above the screws.

1 2 3 4 5 6

Device Manual8/12 4.1-W optosonic 3 radio net

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essenhttp//www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se

on

ly —

Un

iqu

emen

t p

ou

r u

tili

sa

tio

n in

tern

e

1. Open clamping cover.

2. Jumper in as delivered condition.

3. Remove jumper.

The optosonic attempts to set up communication with the heat meter via the optical interface. If this attempt is suc-cessful, the optosonic switches to installation mode for 4 minutes.

4. Parameterizing

with PDA and MGW

5. Following parameterisation or 4 minutes the device switch-es to measuring mode.

▪ Following parameterisation, continue with step 9.

▪ After 4 minutes without parameterisation continue with step 6.

6. Position jumper on the right-hand pins and pull off again af-ter approx. 5 seconds.

The device sends installation beacons for 4 minutes.

7. Parameterizing

with PDA and MGW

8. Following parameterisation or 4 minutes the device switch-es to measuring mode.

▪ Following parameterisation, continue with step 9.

▪ After 4 minutes without parameterisation, continue with step 6 (10 attempts in total).

9. Close clamping cover

10. Seal screw.

11. Clean the device.

4 Commissioning

1 2 3 4 5 6

7 8 9 10 11

Device Manual4.1-W optosonic 3 radio net 9/12

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essen

http://www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se o

nly

— U

niq

uem

en

t p

ou

r u

tili

sat

ion

inte

rne

5.1 Preparatory steps

1. Undo the screws in the opto head. 2. Disconnect the opto head from the sensonic II.

5.2 For installation on mounting plate

1. Remove old optosonic 3 radio net from the mounting plate. 2. Continue with installation from point 7.

5.3 If installing without mounting plate

1. Cut cable ties (for installation without mounting plate). 2. Continue with installation from point 1b.

5 Exchange

1 2

1 2

1 2

Device Manual10/12 4.1-W optosonic 3 radio net

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essenhttp//www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se

on

ly —

Un

iqu

emen

t p

ou

r u

tili

sa

tio

n in

tern

e

6.1 Radio reading AMM

1. Readout via symphonic sensor net.

6.2 Radio reading Walk by

1. Read off appliances

with PDA/MGW by Walk by

2. Check data in the PDA

Are all devices recorded?

6 Reading

1

1 2

Device Manual4.1-W optosonic 3 radio net 11/12

L.83.0050 - Release 8.0.0 CH 2014ista International GmbH - Grugaplatz 2 - 45131 Essen

http://www.ista.com

Nu

r fü

r d

en

inte

rne

n G

eb

rau

ch —

Fo

r in

tern

al u

se o

nly

— U

niq

uem

en

t p

ou

r u

tili

sat

ion

inte

rne

1. Do not dispose of the old device in the household waste.

2. Send obsolete devices to the main warehouse via outlet.

They will ensure proper disposal.

7 Disposal

1 2

Device Manual12/12 4.1-W optosonic 3 radio net