DFS Magnetic Sector GC-HRMS
F T t 2005 t Sᾶ P l 2015
1The world leader in serving science
Dr. Dirk Krumwiede, Dr. Heinz MehlmannThermo Fisher Scientific
From Toronto 2005 to Sᾶo Paulo 2015
10 Anniversary DFS GC-HRMS – Dioxin Conf. 2015
2
Our commitment to the DFS Magnetic Sector GC-HRMS
Buy with confidence...
• Letter of commitment to the Thermo Scientific™ DFS™ Magnetic Sector GC-HRMS
• Thermo Fisher Scientific are committed to
3
Thermo Fisher Scientific are committed to DFS production until at least 2023, likely beyond
• Committed to parts, service and application support until at least 2030, likely longer
Our commitment to the DFS Magnetic Sector GC-HRMS
Buy with confidence...
• Letter of commitment to the DFS Magnetic Sector GC-HRMS
• Thermo Fisher Scientific are committed to DFS d ti til t l t 2023 lik l
4
DFS production until at least 2023, likely beyond
• Committed to parts, service and application support until at least 2030, likely longer
Strong commitment to DFS GC-HRMS as TFS flagship for Dioxin analysis
X
Andreas HilkertDFS product manager
Heinz MehlmannDFS application scientist
Frank Theobald (freelance)DFS instructor
Dirk KrumwiedeDFS application scientist
The faces of the DFS Magnetic Sector GC-HRMS: the application team
5
6
Toronto 2005 to Sᾶo Paulo 2015…
From Toronto 2005…
10 Years after…
7
Photo by Keven Dietrich
From Toronto 2005 to Sᾶo Paulo Today…
10 Years after…
8
Photo by Keven Dietrich
9
DFS GC-HRMS, a look back…
…how did it start?
10
1948: “CH1”, first MS prototype/birth of MAT
- Dr. Ludolf Jenckel(Atlas Werke AG) together with one collegue develops in 1 year the first MS prototype in the cellar of a hospital
11
- After completition he persuades his company to set up a small devision for MS: Atlas MAT
1958: “CH4” – First International Success
- More than 400 installed by 1967
- Applications: e.g.Analysis of coffee aroma (headspace);Perfume mixtures;Cigarette smoke
12
- MAT expands
- Early sixties:GC attached to MS
First GC/MS: CH4 coupled to capillary GC
1972: “MAT 311” (double focusing MS)
13
Max. Resolution ?
1982 – 1986: “8200”
14
1987 – 2005: MAT90 / 95 series
• 1987 - MAT 90• 1992 - MAT 95• 1995 - MAT 95 S• 1998 - MAT 95 XL• 2001 MAT 95 XP
15
• 2001 - MAT 95 XP
Our unique dual GC configuration started with MAT95…
2005: DFS GC-HRMS market introduction, Dioxin conf. Toronto
http://www.dioxin20xx.org/ohc_database_search.htm
16
Jens Griep-RamingProject manager DFSGC-HRMS development
DFS GC-HRMS: from sketch...
17
Original first drawing on a piece of paper by Thermo Fisher Scientific designer
...to reality
18
Note: DFS GC-HRMS as introduced in 2005 with former GC and Autosampler model
DFS GC-HRMS – impressions from R&D time
Construction: “stability test” GC table
GC table can hold 80 Kg!!
19
Electronics: “talking to the boards”
The DFS GC-HRMS key feature? – Toroidal ESA for…
20
…more sensitivity, more ions at same resolution
100 fg 2370 TCDD
DFSGC-HRMS
Same scaling
21
100 fg 2370 TCDD
MAT95
What was new with the DFS GC-HRMS?
• Toroidal ESA for more ions• Instrument shipped in one unit, no assembling of MS onsite• all inside e.g. roughing pumps – only exception: water chiller• moves on wheels• lightest double focusing magnetic sector• State-of-the-art electronics• new robust detector dynode design
22
• new robust detector dynode design• quick exchange ion source• new software, etc., etc.
Almost a benchtop GC-MS, one that stands on the floor……and comes with a built-in bench
The name? Double Focusing Sector “DFS”
2006: DFS GC-HRMS at customer lab in ChinaD:\Xcalibur\...\dk_tcdd22 9/26/2006 11:49:18 AM man. 1 ul 2 fg tcdd (2)new syringe, BACK, DB5 30 m x 0.25 mm (0.1), 120 (2)-15-240(0)-6-270, 0.8 ml/min, splitless 260 C, 1 min, aux 270 C, ists 270, 45 eV, ists 260
RT: 7.61 - 12.47
20
40
60
80
100
ativ
e A
bund
ance
0
20
40
60
80
100
RT: 11.83AA: 83.50
RT: 11.83AA: 114
NL:6.70E1m/z= 319.7970-319.9970 MS ICIS dk_tcdd22
NL:1.12E2m/z= 321.7940-321.9940 MS ICIS dk_tcdd22
2 fg native 2378-TCDD
1/50 dilution of new, sealed, certified 2378-TCDD
23
8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0Time (min)
0
20
40
60
80
100
0
20
40
60
80
100
0
20
Rel
a
RT: 11.83AA: 5584
RT: 11.82AA: 6419
NL:3.63E3m/z= 331.8370-332.0370 MS ICIS dk_tcdd22
NL:3.79E3m/z= 333.8340-334.0340 MS ICIS dk_tcdd22
100 fg 13C labeled 2378-TCDD
certified 2378 TCDD specification solution
24
How do we see the DFS GC-HRMS today?
25
Wh “G ld” St d d?
26
Why “Gold” Standard?
DFS GC-HRMS: Gold Standard for Dioxins
27
DFS GC-HRMS – designed for Dioxin analysis
DFS GC-HRMS: Gold Standard for Dioxins
Proven over 10 years:
o Best Sensitivityo Combined(!) with Robustnesso Long instrument Lifetime
28
DFS GC-HRMS – designed for Dioxin analysis
DFS GC-HRMS robustness – large volume ion source
Foto:Ion source exchange
29
“Robustness by size”
DFS GC-HRMS ion source - designed for combining highest sensitivity with robustness, because sensitivity alone is not enough.
“No, this is not only one single, nicely selected chromatogram”
“Yes, this is an installation spec”
“We demonstrate this specification on every single DFS GC-HRMSduring installation.” 60
65
70
75
80
85
90
95
100
ce
10.83
20 fg 2378-TCDD SN ≥ 200:1 (PtP, 4)
DFS GC-HRMS – Gold Standard Dioxin installationspec
30
• A Dioxin spec, 2378-TCDD • in front of the customer• using a sealed, certified standard
“The best Dioxin spec existing: DFS GC-HRMS - Gold standard Dioxin spec”
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5Time (min)
0
5
10
15
20
25
30
35
40
45
50
55
Rel
ativ
e A
bund
anc
10.91 11.0910.299.09 11.609.268.81 11.268.78 10.04 10.539.749.338.478.137.68 7.92 9.638.407.59
Application NormThermo Scientific
DFSGC-HRMS
Food EU Regulation EU Regulatory Feed Control (at ML) ApprovedFood EU Methods EN 16215 ApprovedFood EURL Recommendation Background food studies (<1/5th EU ML) RecommendedClinical EURL Recommendation Human studies at trace levels RecommendedEnvironmental EU Method EN 1948 ApprovedEnvironmental US Method US EPA 1613 B for strict EPA compliance ApprovedEnvironmental US Method US EPA Method 23 ApprovedEnvironmental US Method US EPA Method 8290 Approved
DFS GC-HRMS – worldwide official method compliance
31
ppEnvironmental Japan Method JIS K0311 ApprovedEnvironmental Japan Method JIS K0312 Approved
DFS GC-HRMS offers worldwide compliance with official Dioxin methods or regulations like EPA 1613 and all others….
…also PCBs, PBDEs (EPA 1668, 1614,…)
RT: 23.82 - 27.83
0
50
100
Rel
ativ
e A
bund
ance
0
50
100
0
50
100
0
50
100
RT: 25.22MA: 375
24.0823.90 25.52 27.40 27.7527.2324.19 24.36 27.0726.2925.3724.54 25.63 26.6625.83 26.9226.4626.0324.74
RT: 25.22MA: 432
24.13 24.52 27.6424.95 27.2926.7726.22 27.0526.0325.54 25.85 26.55 27.5126.9026.3524.67
RT: 25.20AA: 172156
RT: 25.20AA: 218158
NL: 1.13E2m/z= 303.8868-303.9172 MS PCDDF_sample_219448-703_2ul_01
NL: 1.22E2m/z= 305.8837-305.9143 MS PCDDF_sample_219448-703_2ul_01
NL: 4.01E4m/z= 315.9262-315.9578 MS ICIS PCDDF_sample_219448-703_2ul_01
NL: 5.11E4m/z= 317.9231-317.9549 MS ICIS PCDDF_sample_219448-703_2ul_01
DFS GC-HRMS: human serum sample – lowest levels
ca. 3 fg TCDF
32
24.0 24.2 24.4 24.6 24.8 25.0 25.2 25.4 25.6 25.8 26.0 26.2 26.4 26.6 26.8 27.0 27.2 27.4 27.6 27.8Time (min)
0
50
100
0
50
100
0
50
100
0
50
100
0R
RT: 25.81MA: 165
27.54
27.6724.17 27.1625.26 27.4024.60 26.1825.57 26.9926.6624.87 25.9624.39 26.46
RT: 25.85MA: 202
26.73 27.2527.7725.57 27.5424.61 27.1224.32 26.6026.2224.02 25.26 25.4624.96 27.0125.70 26.4626.05
RT: 25.22AA: 153519
RT: 25.79AA: 116608
RT: 25.22AA: 198314 RT: 25.79
AA: 159458
NL: 7.50E1m/z= 319.8810-319.9130 MS PCDDF_sample_219448-703_2ul_01
NL: 7.00E1m/z= 321.8779-321.9101 MS PCDDF_sample_219448-703_2ul_01
NL: 3.52E4m/z= 331.9204-331.9536 MS ICIS PCDDF_sample_219448-703_2ul_01
NL: 4.62E4m/z= 333.9173-333.9507 MS ICIS PCDDF_sample_219448-703_2ul_01
ca. 2 fg TCDD
For research purposes only. Not for use in diagnostic procedures.
Why has the DFS GC-HRMS been so successful?
finally we know it
33
…finally we know it…
POPs want to be analyzed by DFSGC-HRMS!!
.. have a closer look into the World of Dioxins..
34
• Market leader in Dioxin analysis • DFS GC-HRMS is designed for
Dioxin analysis• worldwide use in Dioxin expert labs
• Worldwide method compliance• Dioxins, PCBs, PBDEs• EPA 1613 1668 1614 & others
DFS GC-HRMS benefits at one glance
• Specification• Gold standard Dioxin spec, best Dioxin
spec on the market, best sensitivity• Dioxin spec shown at every installation
• Proven, safe bet• DFS GC-HRMS is the “gold standard”
and benchmark for Dioxins
35
• EPA 1613,1668,1614 & others• Use PFK, lockmass trace etc.
• References (since 2005)• installed in hundreds of Dioxin labs• Proven in >> 100.000 injections• round robin tests since 2005 • scientific papers
and benchmark for Dioxins• Be prepared for all Dioxin applications• Unique Dual GC configuration
• Superior performance• DFS GC-HRMS = ultimate analytical
performance: sensitivity, linearity etc. combined with robustness & long instrument lifetime
Thank Thank you for you for your attention your attention