dgn -a - hertfordshire · 2019. 2. 4. · material scheme ref. background border letter colour ref....
TRANSCRIPT
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
N.T.S.
Key:
railway bridge
Low headroom
Royston Road junction
A507 Clothall Rd /
Baldock
A1(M) Junction 9
CotteredA507 / Warren Lane
A505
A507
001 R0NS
NS PAS 01/19
R0 First Issue PAS Jan 19
To Royston
A1(M)
Wallington
Rushden
Weston
Throcking Road
A507 /
Informatory Sign Locations
Existing HGV Prohibition &
for wide vehicles' Signage
Existing 'Unsuitable for HGVs' / 'Unsuitable
Existing 7.5T Weight Restriction Signage
Existing 5T Time Limited Weight Restriction Signage
ITP-180012-1-S1-001-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
01-A
3.d
gn
APPENDIX 1A
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
N.T.S.
Sign Locations
Option 1A: Proposed HGV Prohibition
Key:
7.5T Sign Locations
Proposed ADS Locations
Proposed HGV Routing Sign Locations
Proposed 7.5T Weight Restrictions
Notes:
Baldock Services
railway bridge
Low headroom
Royston Road junction
A507 Clothall Rd /
Baldock
A1(M) Junction 9
CotteredA507 / Warren Lane
A507 / Throcking Road
Buntingford
A10
A505
A507
ADS1
ADS2
ADS3
S1
S2
S3
S5
ADS4
ADS5
ADS6
W1
W2
010 R0NS
NS PAS 01/19
R0 First Issue PAS Jan 19
To Royston
To Cambridge
A1(M) Junction 10
A1(M)
To A602
Wallington
Rushden
Weston
W2
W2
W2
W2
W2
W2
W2
W2
W2
W2
W1
S6
S4
ITP-180012-1-S1-013-A3 3. For details of HGV weight restriction signs see drawing
2. For details of ADS signs see drg. ITP-180012-1-S1-012-A3
1. For details of HGV routing signs see drg. ITP-180012-1-S1-011-A3
ITP-180012-1-S1-010-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
10-A
3.d
gn
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S1
A507 Option 1A
100.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 3.31m²
1150mm
2875mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S5
A507 Option 1A
75.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 1.34m²
845mm
1590mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S4
A507 Option 1A
100.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 2.16m²
1125mm
1920mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S6
A507 Option 1A
100.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 2.40m²
1125mm
2130mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S2
A507 Option 1A
75.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 1.28m²
845mm
1520mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S3
A507 Option 1A
75.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 0.65m²
620mm
1055mm
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
N.T.S.NS
NS PAS 01/19
011 R0
Notes: R0 First Issue PAS Jan 19
Option 1A: Advisory HGV Route Signage Details
ITP-180012-1-S1-010-A3 (red circles)
1. For details of proposed sign locations see drawing
ITP-180012-1-S1-011-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
11-A
3.d
gn
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS1
A507 Option 1A
125.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 6.29m²
1750mm
3595mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS2
A507 Option 1A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 4.11m²
1765mm
2335mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS3
A507 Option 1A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 4.11m²
1765mm
2335mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS5
A507 Option 1A
100.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 6.89m²
2505mm
2750mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS6
A507 Option 1A
100.0
WHITE
DARK GREEN
WHITE
Class R3B Microprismatic 7.44m²
2200mm
3385mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS4
A507 Option 1A
100.0
WHITE
DARK GREEN
WHITE
Class R3B Microprismatic 6.76m²
1995mm
3385mm
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
Option 1A: Advanced Directional
N.T.S.NS
NS PAS 01/19
012 R0
Notes: R0 First Issue PAS Jan 19
Signage Details
ITP-180012-1-S1-010-A3 (green circles)
1. For details of proposed sign locations see drawing
ITP-180012-1-S1-012-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
12-A
3.d
gn
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W1
A507 Option 1A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 0.39m²
431mm
906mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W2
A507 Option 1A
62.5
BLACK
WHITE
BLACK
Class R3B Microprismatic 0.27m²
360mm
755mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W1A
A507 Option 1A
-
BLACK
WHITE
BLACK
Class R3B Microprismatic 0.44m²
750mm
750mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W2A
A507 Option 1A
-
BLACK
WHITE
BLACK
Class R3B Microprismatic 0.28m²
600mm
600mm
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
N.T.S.NS
NS PAS 01/19
013 R0
Notes: R0 First Issue PAS Jan 19
Signage Details
Option 1A: Weight Restriction
ITP-180012-1-S1-010-A3 (blue circles)
1. For details of proposed sign locations see drawing
ITP-180012-1-S1-013-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
13-A
3.d
gn
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
N.T.S.
Sign Locations
Option 2A: Proposed HGV Prohibition
Key:
7.5T Sign Locations
Proposed ADS Locations
Proposed HGV Routing Sign Locations
Proposed 7.5T Weight Restrictions
Notes:
Baldock Services
railway bridge
Low headroom
Royston Road junction
A507 Clothall Rd /
Baldock
A1(M) Junction 9
CotteredA507 / Warren Lane
A507 / Throcking Road Buntingford
A10
A505
A507
ADS1
ADS2
ADS3
ADS5
ADS6
ADS7
S1
S2S4
S3
S6
ADS8
ADS9
W1
W2
W3
W4
W5
W6
W7
W2
W2
020 R0NS
NS PAS 01/19
R0 First Issue PAS Jan 19
To Royston
To Cambridge
A1(M) Junction 10
A1(M)
To A602
Wallington
Rushden
Weston
ADS4
ADS10
S5
S7
W8
W9
ITP-180012-1-S1-024-A3
3. For details of HGV weight restriction signs see drawing
2. For details of ADS signs see drg. ITP-180012-1-S1-022 & 23-A3
1. For details of HGV routing signs see drg. ITP-180012-1-S1-021-A3
ITP-180012-1-S1-020-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
20-A
3.d
gn
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S1
A507 Option 2A
100.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 3.31m²
1150mm
2875mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S2
A507 Option 2A
75.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 1.30m²
855mm
1530mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S3
A507 Option 2A
75.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 0.65m²
620mm
1055mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S5
A507 Option 2A
100.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 2.18m²
1140mm
1920mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S4
A507 Option 2A
75.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 0.75m²
620mm
1205mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S6
A507 Option 2A
75.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 1.36m²
855mm
1590mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign HGV S7
A507 Option 2A
100.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 2.43m²
1140mm
2130mm
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
N.T.S.NS
NS PAS 01/19
021 R0
Notes: R0 First Issue PAS Jan 19
Option 2A: Advisory HGV Route Signage Details
ITP-180012-1-S1-020-A3 (red circles)
1. For details of proposed sign locations see drawing
ITP-180012-1-S1-021-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
21-A
3.d
gn
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS5
A507 Option 2A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 2.19m²
2150mm
1020mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS7
A507 Option 2A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 2.27m²
1350mm
1680mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS1
A507 Option 2A
125.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 6.29m²
1750mm
3595mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS6
A507 Option 2A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 2.16m²
1340mm
1615mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS2
A507 Option 2A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 5.34m²
2270mm
2350mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS3
A507 Option 2A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 5.34m²
2270mm
2350mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS4
A507 Option 2A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 4.60m²
1905mm
2420mm
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
Option 2A: Advanced Directional
N.T.S.NS
NS PAS 01/19
022 R0
Notes: R0 First Issue PAS Jan 19
Signage Details (Sheet 1 of 2)
ITP-180012-1-S1-020-A3 (green circles)
1. For details of proposed sign locations see drawing
ITP-180012-1-S1-022-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
22-A
3.d
gn
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS8
A507 Option 2A
100.0
WHITE
DARK GREEN
WHITE
Class R3B Microprismatic 7.78m²
2295mm
3385mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS9
A507 Option 2A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 4.46m²
2160mm
2060mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign ADS10
A507 Option 2A
100.0
WHITE
DARK GREEN
WHITE
Class R3B Microprismatic 8.33m²
2465mm
3385mm
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
Option 2A: Advanced Directional
N.T.S.NS
NS PAS 01/19
023 R0
Notes: R0 First Issue PAS Jan 19
Signage Details (Sheet 2 of 2)
ITP-180012-1-S1-020-A3 (green circles)
1. For details of proposed sign locations see drawing
ITP-180012-1-S1-023-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
23-A
3.d
gn
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W8
A507 Option 2A
62.5
WHITE
BLUE
WHITE
Class R3B Microprismatic 0.95m²
1015mm
935mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W1
A507 Option 2A
100.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 0.69m²
575mm
1210mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W2
A507 Option 2A
62.5
BLACK
WHITE
BLACK
Class R3B Microprismatic 0.27m²
360mm
755mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W3
A507 Option 2A
62.5
WHITE
DARK GREEN
WHITE
Class R3B Microprismatic 0.87m²
1050mm
830mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W1A
A507 Option 2A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 0.39m²
430mm
905mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W2A
A507 Option 2A
75.0
BLACK
WHITE
BLACK
Class R3B Microprismatic 0.39m²
430mm
905mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W4
A507 Option 2A
62.5
WHITE
DARK GREEN
WHITE
Class R3B Microprismatic 0.87m²
1050mm
830mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W5
A507 Option 2A
62.5
WHITE
DARK GREEN
WHITE
Class R3B Microprismatic 0.87m²
1050mm
830mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W6
A507 Option 2A
62.5
WHITE
BLUE
WHITE
Class R3B Microprismatic 0.86m²
1015mm
845mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W7
A507 Option 2A
62.5
WHITE
DARK GREEN
WHITE
Class R3B Microprismatic 0.87m²
1050mm
830mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign W9
A507 Option 2A
100.0
WHITE
BLUE
WHITE
Class R3B Microprismatic 2.43m²
1625mm
1495mm
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
N.T.S.NS
NS PAS 01/19
024 R0
Notes: R0 First Issue PAS Jan 19
Signage Details
Option 2A: Weight Restriction
ITP-180012-1-S1-020-A3 (blue circles)
1. For details of proposed sign locations see drawing
ITP-180012-1-S1-024-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
24-A
3.d
gn
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign A10 / A120 S1
A507
100.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 3.00m²
1140mm
2640mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign A10 / A120 S2
A507
100.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 3.23m²
1140mm
2840mm
Material
Scheme Ref.
Background
Border
Letter colour
Ref.
SIGN FACE
Width
Height
Area
x-heightSign A10 / A120 S3
A507
100.0
WHITE
BLACK
WHITE
Class R3B Microprismatic 3.13m²
1140mm
2750mm
Approved Revision DateRevision Amendment
100
50
150
mm
Original Sheet Size A3 [420x297]
10
mm
0
Scales Project No. Sheet. No.
Project
Sheet
RevisionDrawn
Approved Approved DateDesigned
Crown copyright and database right to 2018 Ordnance Survey 100019606 ©
(This restriction may not apply to HCC and its licensed contractors, agents & partners.)
any form.
You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in
COUNTY HALL
Pegs Lane
Hertford, Herts
SG13 8DN
Phone: 01992 555555
A507 HGV Study
N.T.S.
Notes:
A1(M) Junction 6
A10
A602
020 R0NS
NS PAS 01/19
R0 First Issue PAS Jan 19
To Cambridge
A1(M)
To A602
S1
S2
S3
S3
A120
Ware
A602
A1(M) Junction 7
Stevenage
Diversion Signage
Proposed A120 / A10 Advisory HGV
Junction
A10 / A602
- A120 to Baldock / A1(M) via A602
Proposed Advisory HGV Signage
Option 1A and Option 2A
1. Proposed diversion signage applies to
ITP-180012-1-S1-030-A3
J:\255000\2
55670-1
9\4 Intern
al Project
Data\4-0
3 Dra
win
gs\0
_Dra
win
gs\ITP-1
80012-1-S
1-0
30-A
3.d
gn