dialight led lighting fixture catalog · 2018-08-31 · vigilant® led high bay 18-20 ® led high...
TRANSCRIPT
Dialight LED Lighting Fixture Catalog for Industrial and Hazardous Locations
Dialight LED Lighting Fixture Catalogfor Industrial and Hazardous Locations
Products and solutions that protect your business
On when it matters most.Products and solutions that protect your business
On when it matters most.Products and solutions that protect your business
Value Proposition • 10+ years of maintenance free lighting
• Improved safety, color quality
• Improved temperature rating (T-rating)
• Lower total cost of ownership, quick ROI
• Lower energy consumption by > 50%
Vigilant®
• LED lighting for industrial applications
So worte®
• LED lighting for hazardous applications
DuroSite®
• LED lighting for industrial applications
About Dialight
Dialight (LSE: DIA.L) is leading the
energy efficient LED lighting revolution
around the world for industrial and
hazardous areas. For more than 40
years, it has been committed to the
development of LED lighting solutions
that enable organizations to vastly
reduce energy use and maintenance
needs, improve safety, ease of disposal
and reduce CO2 emissions.
About Dialight
Dialight (LSE: DIA.L) is leading the
energy efficient LED lighting revolution
around the world for industrial and
hazardous areas. For more than 40
years, it has been committed to the
development of LED lighting solutions
that enable organizations to vastly
reduce energy use and maintenance
needs, improve safety, ease of disposal
and reduce CO2 emissions.
Value Proposition• 10+ years of maintenance free lighting
• Improved safety, color quality
• Improved temperature rating (T-rating)
• Lower total cost of ownership, quick ROI
• Lower energy consumption by > 50%
Vigilant®
• LED lighting for industrial applications
SafeSite®
• LED lighting for hazardous applications
DuroSite®
• LED lighting for industrial applications
t ' r
\ . , yi C W
_led
\ &, ;-/ . 4 1 - • y
1 ,
u.
Table of Contents
Vigilant® High Efficiency LED Lighting for Industrial Applications Vigilant® LED Lighting Fixtures for Industrial Applications Overview 6 Vigilant® LED High Bay - 60,000lm 14-15 Vigilant® H2 Series LED High Bay 16-17 Vigilant® LED High Bay 18-20 Vigilant® LED High Bay 480V AC Passive Power Supply 21-22 Vigilant® LED Dual Floodlight 23-24 Vigilant® LED High Bay with DALI or Wireless Controls 25-26 Wireless Occupancy Sensor 27
DuroSite® LED Lighting for Industrial Applications DuroSite® LED Lighting Fixtures for Industrial Applications Overview 7-8 DuroSite® LED High Bay 28-32 DuroSite® LED Low Bay 33-34 DuroSite® LED Floodlight 34-35 DuroSite® LED End-to-End Linear 36-37 DuroSite® LED Linear - Low Profile 38-39 DuroSite® LED Linear - Top Conduit 40-41 DuroSite® LED Linear - Battery Backup 42 DuroSite® LED Area Light 43-47 DuroSite® LED Wallpack / Bulkhead 48-50 DuroSite® RTO LED Area Light 51-52
-..i
IP
SafeSite® LED Lighting for Hazardous Applications SafeSite® LED Lighting Fixtures for Hazardous Applications Overview 9-10 SafeSite® LED High Bay - High Efficiency 54-57 SafeSite® LED High Bay 58-60 SafeSite® LED Floodlight 61-62 SafeSite® LED End-to-End Linear 63-64 SafeSite® LED Linear - Low Profile 65-66 SafeSite® LED Linear - Top Conduit 67-68 SafeSite® LED Linear - Battery Backup 69-70 SafeSite® LED Linear - Class I Div. 1 71-72 SafeSite® LED Linear - Battery Backup - Class I Div. 1 73-74 SafeSite® LED Area Light 75-82 SafeSite® LED Wallpack / Bulkhead 83-85 SafeSite® RTO LED Area Light 86-87 SafeSite® LED High Bay with DALI or Wireless Controls 61
JtreetSense® LED Fixture for Infrastructure Solutions StreetSense® LED Street Light 88-89
Dialight LED Obstruction Lighting for Signaling Solutions Obstruction Lighting Solutions Overview
11
FAA Approved Obstruction Lighting Solutions
90-91
5 5
Table of Contents
5
Table of Contents
Vigilant® High Efficiency LED Lighting for Industrial ApplicationsVigilant® LED Lighting Fixtures for Industrial Applications Overview 6Vigilant® LED High Bay - 60,000lm 14-15Vigilant® H2 Series LED High Bay 16-17Vigilant® LED High Bay 18-20Vigilant® LED High Bay 480V AC Passive Power Supply 21-22Vigilant® LED Dual Floodlight 23-24Vigilant® LED High Bay with DALI or Wireless Controls 25-26Wireless Occupancy Sensor 27
DuroSite® LED Lighting for Industrial ApplicationsDuroSite® LED Lighting Fixtures for Industrial Applications Overview 7-8DuroSite® LED High Bay 28-32DuroSite® LED Low Bay 33-34DuroSite® LED Floodlight 34-35DuroSite® LED End-to-End Linear 36-37DuroSite® LED Linear - Low Profile 38-39DuroSite® LED Linear - Top Conduit 40-41DuroSite® LED Linear - Battery Backup 42DuroSite® LED Area Light 43-47DuroSite® LED Wallpack / Bulkhead 48-50DuroSite® RTO LED Area Light 51-52
SafeSite® LED Lighting for Hazardous ApplicationsSafeSite® LED Lighting Fixtures for Hazardous Applications Overview 9-10SafeSite® LED High Bay - High Efficiency 54-57SafeSite® LED High Bay 58-60SafeSite® LED Floodlight 61-62SafeSite® LED End-to-End Linear 63-64SafeSite® LED Linear - Low Profile 65-66SafeSite® LED Linear - Top Conduit 67-68SafeSite® LED Linear - Battery Backup 69-70SafeSite® LED Linear - Class I Div. 1 71-72SafeSite® LED Linear - Battery Backup - Class I Div. 1 73-74SafeSite® LED Area Light 75-82SafeSite® LED Wallpack / Bulkhead 83-85SafeSite® RTO LED Area Light 86-87SafeSite® LED High Bay with DALI or Wireless Controls 61
StreetSense® LED Fixture for Infrastructure SolutionsStreetSense® LED Street Light 88-89
Dialight LED Obstruction Lighting for Signaling SolutionsObstruction Lighting Solutions Overview 11FAA Approved Obstruction Lighting Solutions 90-91
011111.1111Bli
Vigilant
Vigilant® LED Lighting Fixtures for Industrial Applications
Overview I Industrial Applications
LED High Bay - 60,000Im Wattage Range: 480W / 520W
Lumen Output: 60,000Im
Lumens per Watt: 125 - 115
Input Voltage: 120 - 277V AC, 480V AC
LED High Bay Wattage Range: 212W/ 144W/ 112W/ 88W
Lumen Output Range: 26,500 - 11,000Im
Lumens per Watt: 125
Input Voltage: 100 - 277V AC, 110 - 277V AC
LED High Bay - H2 Series LED High Bay Wattag 180W / 192W
Lumen Output: 25,2501m
Lumens per Watt: 140 - 132
Input Voltage: 110 - 277V AC, 480V AC
LED High Bay - Passive Power Supply Wattage Range 144W
Lumen Output: 18,000Im
Lumens per Watt: 125
Input Voltage: 480V AC
LED Dual Floodlight Wunuge KungL 496W / 424W / 360W / 312W / 288W
Lumen Output Range: 55,000 - 37,5001m
Lumens per Watt: 130 - 104
Input Voltage: 120 - 277V AC
347V AC
480V AC When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
6
www.dialight.com
When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
6 www.dialight.com
Vigilant® LED Lighting Fixturesfor Industrial Applications
Overview | Industrial ApplicationsVigilant
LED High Bay - 60,000lmWattage Range: 480W / 520W
Lumen Output: 60,000lm
Lumens per Watt: 125 - 115
Input Voltage: 120 - 277V AC, 480V AC
LED High BayWattage Range: 212W / 144W / 112W / 88W
Lumen Output Range: 26,500 - 11,000lm
Lumens per Watt: 125
Input Voltage: 100 - 277V AC, 110 - 277V AC
LED High Bay - H2 Series LED High BayWattage Range: 180W / 192W
Lumen Output: 25,250lm
Lumens per Watt: 140 - 132
Input Voltage: 110 - 277V AC, 480V AC
LED High Bay - Passive Power SupplyWattage Range: 144W
Lumen Output: 18,000lm
Lumens per Watt: 125
Input Voltage: 480V AC
LED Dual FloodlightWattage Range: 496W / 424W / 360W / 312W / 288W
Lumen Output Range: 55,000 - 37,500lm
Lumens per Watt: 130 - 104
Input Voltage: 120 - 277V AC
347V AC
480V AC
Overview I Industrial Applications DuroSite
DuroSite® LED Lighting Fixtures for Industrial Application;
LED High Bay Wattage Range: 172 - 107W
Lumen Output Range: 17,000 - 8,5001m
Lumens per Watt:: 99 - 69
Input Voltage: 100 - 277V AC
347 - 480V AC
120 - 250V DC
LED Low Bay wattage mange: 140 - 45W
Lumen Output Range: 8,750 - 3,8001m
Lumens per Watt: 84 - 62
Input Voltage: 100 - 277V AC
347 - 480V AC
LED Floodlight Wattage Range: 140 - 109W
Lumen Output Range: 15,000 - 10,5001m
Lumens per Watt: 115 - 89
Input Voltage: 100 - 277V AC
347 - 480V AC
LED Linear - End-to-End Wattage Range: 60 / 32W
Lumen Output Range: 7,500 - 3,5001m
Lumens per Watt: 125
Input Voltage: 120 - 277V AC
LED Linear - Low Profile Wattage Range: 66 / 33W
Lumen Output Range: 7,250 - 3,3001m
Lumens per Watt: 110 - 100
Input Voltage: 100 - 277V AC
When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
www.dialight.com 7
DuroSite® LED Lighting Fixturesfor Industrial Applications
DuroSiteOverview | Industrial Applications
www.dialight.com 7
When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
LED High BayWattage Range: 172 - 107W
Lumen Output Range: 17,000 - 8,500lm
Lumens per Watt:: 99 - 69
Input Voltage: 100 - 277V AC
347 - 480V AC
120 - 250V DC
LED Low BayWattage Range: 140 - 45W
Lumen Output Range: 8,750 - 3,800lm
Lumens per Watt: 84 - 62
Input Voltage: 100 - 277V AC
347 - 480V AC
LED FloodlightWattage Range: 140 - 109W
Lumen Output Range: 15,000 - 10,500lm
Lumens per Watt: 115 - 89
Input Voltage: 100 - 277V AC
347 - 480V AC
LED Linear - Low ProfileWattage Range: 66 / 33W
Lumen Output Range: 7,250 - 3,300lm
Lumens per Watt: 110 - 100
Input Voltage: 100 - 277V AC
LED Linear - End-to-EndWattage Range: 60 / 32W
Lumen Output Range: 7,500 - 3,500lm
Lumens per Watt: 125
Input Voltage: 120 - 277V AC
DuroSite
DuroSite® LED Lighting Fixtures for Industrial Applications
Overview I Industrial Applications
LED Linear - Top Conduit .ange: 66 / 33W
Lumen Output Range: 7,250 - 3,3001m
Lumens per Watt:: 110 - 100
Input Voltage: 100 - 277V AC
LED Area Light Kungt 69 - 21W
Lumen Output Range: 7,250 - 2,2001m
Lumens per Watt:: 105 - 94
Input Voltage: 100 - 277V AC
347 - 480V AC
24 - 48V DC
LED Wallpack / Bulkhead Wattage Range 34W/ 22W/ 11W
Lumen Output Range: 2,250 - 6001m
Lumens per Watt:: 66 - 55
Input Voltage: 100 - 277V AC
24 - 48V DC
LED RTO Area Light Wattage Range: 8W
Lumen Output Range: 800 - 4001m
Lumens per Watt:: 100 - 59
Input Voltage: 100 - 277V AC
12 - 48V DC
When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
8
www.dialight.com
When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
8 www.dialight.com
DuroSite® LED Lighting Fixturesfor Industrial Applications
Overview | Industrial ApplicationsDuroSite
LED Area LightWattage Range: 69 - 21W
Lumen Output Range: 7,250 - 2,200lm
Lumens per Watt:: 105 - 94
Input Voltage: 100 - 277V AC
347 - 480V AC
24 - 48V DC
LED Wallpack / BulkheadWattage Range: 34W / 22W / 11W
Lumen Output Range: 2,250 - 600lm
Lumens per Watt:: 66 - 55
Input Voltage: 100 - 277V AC
24 - 48V DC
LED RTO Area LightWattage Range: 8W
Lumen Output Range: 800 - 400lm
Lumens per Watt:: 100 - 59
Input Voltage: 100 - 277V AC
12 - 48V DC
LED Linear - Top ConduitWattage Range: 66 / 33W
Lumen Output Range: 7,250 - 3,300lm
Lumens per Watt:: 110 - 100
Input Voltage: 100 - 277V AC
Overview I Hazardous Applications SafeSite
SafeSite® LED Lighting Fixtures for Hazardous Application
LED High Bay - High Efficiency Wattage Range: 212 - 88W
Lumen Output Range: 26,500 - 11,000Im
Lumens per Watt:: 125 - 110
Input Voltage: 100 - 277V AC
110 - 277V AC
LED High Bay Wattage Range 270 - 123W
Lumen Output Range: 25,000 - 8,5001m
Lumens per Watt:: 103 - 69
Input Voltage: 100 - 277V AC
347 - 480V AC
LED Floodlight Wattage Ranh__ 140 - 109W
Lumen Output Range: 15,000 - 10,5001m
Lumens per Watt:: 115 - 89
Input Voltage: 100 - 277V AC
347 - 480V AC
LED Linear - End-to-End Wattage Range: 60 / 32W
Lumen Output Range: 7,500 - 3,5001m
Lumens per Watt: 125
Input Voltage: 120 - 277V AC
LED Linear - Low Profile Wattage Range: 66 / 33W
Lumen Output Range: 7,250 - 3,3001m
Lumens per Watt:: 110 - 100
Input Voltage: 100 - 277V AC
When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
www.dialight.com 9
SafeSite® LED Lighting Fixturesfor Hazardous Applications
SafeSiteOverview |Hazardous Applications
www.dialight.com 9
When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
LED High BayWattage Range: 270 - 123W
Lumen Output Range: 25,000 - 8,500lm
Lumens per Watt:: 103 - 69
Input Voltage: 100 - 277V AC
347 - 480V AC
LED High Bay - High EfficiencyWattage Range: 212 - 88W
Lumen Output Range: 26,500 - 11,000lm
Lumens per Watt:: 125 - 110
Input Voltage: 100 - 277V AC
110 - 277V AC
LED FloodlightWattage Range: 140 - 109W
Lumen Output Range: 15,000 - 10,500lm
Lumens per Watt:: 115 - 89
Input Voltage: 100 - 277V AC
347 - 480V AC
LED Linear - Low ProfileWattage Range: 66 / 33W
Lumen Output Range: 7,250 - 3,300lm
Lumens per Watt:: 110 - 100
Input Voltage: 100 - 277V AC
LED Linear - End-to-EndWattage Range: 60 / 32W
Lumen Output Range: 7,500 - 3,500lm
Lumens per Watt: 125
Input Voltage: 120 - 277V AC
SafeSite
ciSite(5) LED Lighting Fixtures for Hazardous Applications
Overview I Hazardous Applications
LED Linear - Top Conduit Wattage Range: 66 / 33W
Lumen Output Range: 7,250 - 3,3001m
Lumens per Watt:: 110 - 100
Input Voltage: 100 - 277V AC
LED Linear - Battery Backup Wattage Range: 85W
Lumen Output Range: 7,000Im
Lumens per Watt:: 85
Input Voltage: 120 - 277V AC
LED Linear - CID1 Wattage Range: 78W / 39W
Lumen Output Range: 7,250 - 3,6001m
Lumens per Watt:: 93 - 92
Input Voltage: 100 - 277V AC
347 - 480V AC
LED Area Light Wattage Range: 68 - 21W
Lumen Output Range: 7,250 - 2,2001m
Lumens per Watt:: 105 - 94
Input Voltage: 100 - 277V AC
347 - 480V AC
24 - 48V DC
LED Wallpack / Bulkhead Wattage Range. 34W/ 22W/ 11W
Lumen Output Range: 2,250 - 6001m
Lumens per Watt:: 66 - 55
Input Voltage: 100 - 277V AC
24 - 48V DC
When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
10
www.dialight.com
When ordering, please refer to www.dialight.com and the current datasheets to ensure proper and most up to date information.
10 www.dialight.com
SafeSite® LED Lighting Fixturesfor Hazardous Applications
Overview | Hazardous ApplicationsSafeSite
LED Area LightWattage Range: 68 - 21W
Lumen Output Range: 7,250 - 2,200lm
Lumens per Watt:: 105 - 94
Input Voltage: 100 - 277V AC
347 - 480V AC
24 - 48V DC
LED Wallpack / BulkheadWattage Range: 34W / 22W / 11W
Lumen Output Range: 2,250 - 600lm
Lumens per Watt:: 66 - 55
Input Voltage: 100 - 277V AC
24 - 48V DC
LED Linear - Battery BackupWattage Range: 85W
Lumen Output Range: 7,000lm
Lumens per Watt:: 85
Input Voltage: 120 - 277V AC
LED Linear - CID1Wattage Range: 78W / 39W
Lumen Output Range: 7,250 - 3,600lm
Lumens per Watt:: 93 - 92
Input Voltage: 100 - 277V AC
347 - 480V AC
LED Linear - Top ConduitWattage Range: 66 / 33W
Lumen Output Range: 7,250 - 3,300lm
Lumens per Watt:: 110 - 100
Input Voltage: 100 - 277V AC
Signals
Obstruction LED Lighting Solutions FAQ► Approved ObsTrucrion Lignring Solutions
Vigilant LED Based L-856 / L-864 High Intensity (White / Red) Strobe Effective Intensity:
White Day - 270,000 cd White Twilight - 20,000 cd White or Red Night - 2,000 cd
Wattage:
White Day - 220W White Twilight - 40W White or Red Night - 30W
Input Voltage:
208 - 277V AC
Effective Intensity:
White Day - 20,000 cd White Night - 2,000 cd Red Night - 2,000 cd
Wattage:
White Day - 36W (system = 75W) White Night - 4W (system = 10VV) Red Night - 12W (system = 25W)
Input Voltage:
120 - 240V AC or +/-48V DC
Obstruction Signals I FAA Approved
Vigilant LED Based L-865 / L-864 (+IR) Medium Intensity (White/Red) Strooe - mrrared (IR) available
Vigilant LED Based L-864 (+IR) Medium Intensity (Red) Beacon - Infrared (IR) available Effective Intensity: 2,000 cd
Wattage: 3.3W (16.7% duty circle) - standard 7.0W (16.7% duty circle) - IR model 20 flashes per minute with 0.5 sec. on time
Input Voltage: 120 - 240V AC or 24 - 48V DC
Vigilant LED Based 1-810 Lc Intensity (ReL, RTO Side Light - Infrared (IR) available Effective Intensity: 32.5 cd
Wattage Range: 1.5 - 9.0W
Input Voltage: 12 - 48V DC / 120 - 240V AC / 277V AC
Vigilant LED Based 1-810 Low Intensity (Red) RTO Side Light - Infrared (IR) available Effective Intensity: 32.5 cd
Wattage Range: 13 - 24W
Input Voltage: 12 - 48V DC / 120V AC / 230 V AC
www.dialight.com 11
Signals Obstruction Signals| FAA Approved
www.dialight.com 11
Obstruction LED Lighting SolutionsFAA Approved Obstruction Lighting Solutions
Vigilant LED Based L-856 / L-864High Intensity (White / Red) StrobeEffective Intensity: White Day - 270,000 cd White Twilight - 20,000 cd White or Red Night - 2,000 cd
Wattage: White Day - 220W White Twilight - 40W White or Red Night - 30W
Input Voltage: 208 - 277V AC
Vigilant LED Based L-865 / L-864 (+IR)Medium Intensity (White/Red) Strobe - Infrared (IR) availableEffective Intensity: White Day - 20,000 cd White Night - 2,000 cd Red Night - 2,000 cd
Wattage: White Day - 36W (system = 75W) White Night - 4W (system = 10W) Red Night - 12W (system = 25W)
Input Voltage: 120 - 240V AC or +/-48V DC
Vigilant LED Based L-864 (+IR)Medium Intensity (Red) Beacon - Infrared (IR) availableEffective Intensity: 2,000 cd
Wattage: 3.3W (16.7% duty circle) - standard 7.0W (16.7% duty circle) - IR model 20 flashes per minute with 0.5 sec. on time
Input Voltage: 120 - 240V AC or 24 - 48V DC
Vigilant LED Based L-810Low Intensity (Red) RTO Side Light - Infrared (IR) availableEffective Intensity: 32.5 cd
Wattage Range: 1.5 - 9.0W
Input Voltage: 12 - 48V DC / 120 - 240V AC / 277V AC
Vigilant LED Based L-810Low Intensity (Red) RTO Side Light - Infrared (IR) availableEffective Intensity: 32.5 cd
Wattage Range: 13 - 24W
Input Voltage: 12 - 48V DC / 120V AC / 230 V AC
12
Case Study
Dialight Installation Case Studies Industrial Applications Soiunons
Industrial Applications I Case Study
Diamond Pet Foods, Ripon, CA New Diamond Pet Foods Facility Achieves Less than Two Year Payback with Dialight's SafeSite LED Lighting Fixtures
Installation Snapshot
• 300,000 sq. ft. facility, Class II Div 2 • <2 year payback • 24/7 lighting indoor, 12/7 lighting outdoor on photocell • 500+ Class II Div 2 and general purpose fixtures installed: • Energy rate - $0.136/kWh • Energy savings: at least 50% • Up to 10 years of zero maintenance
City of Tulsa Case Study (Water Treatment Plant) City of Tulsa Waxer riant Curs Annual energy Elm ay ,22K, Saves $10K per Year on Maintenance with Upgrade to Dialight LED Lighting
Installation Snapshot
• Replaced 350 HID, metal halide and 112 fixtures at A.B. Jewell with 259 Dialight LED fixtures including:
• 446,576 kWh saved • $22,300 annual energy savings • $32,000 utility incentive • $10,000 per year saved on lighting maintenance
Donjon Shipbuilding Case Study (Shipbuilding) Donjon Shipbuilding Replaces 250+ HIDs with Just 79 Dialight LEDs to Achieve "Night & Day" Lighting Improvement & Eliminate Lighting maintenance
Installation Snapshot
• Donjon Shipbuilding 200,000 sq. ft. open air production building and dry dock • 92-foot and 125-foot mounting height • 266 existing 1000w Metal Halides • Replaced with just 79 Dialight 60,000 lumen Vigilant High Bays • Reduced fixture count by 70% • A decade of zero maintenance, backed by 10-year, full performance warranty
MMD Shipping Case Study (Cold Storage) The long-life performance of the Dialight LEDs will significantly reduce MMD's lighting maintenance needs, which were once a costly and cumbersome exercise
Installation Snapshot
• New installation • (134) 150W LED High Bays w/ occ sensors • (16) 80W LED Low Bays w/ occ sensors
• Delivered light: -300 lux • Payback: 2 years • 19% return from UK's Enhanced Capital Allowance (ECA) scheme
www.dialight.com
Case Study Industrial Applications| Case Study
12 www.dialight.com
Dialight Installation Case StudiesIndustrial Applications Solutions
Diamond Pet Foods, Ripon, CANew Diamond Pet Foods Facility Achieves Less than Two Year Payback with Dialight’s SafeSite LED Lighting Fixtures
Installation Snapshot
• 300,000 sq. ft. facility, Class II Div 2• <2 year payback• 24/7 lighting indoor, 12/7 lighting outdoor on photocell• 500+ Class II Div 2 and general purpose fixtures installed:• Energy rate - $0.136/kWh• Energy savings: at least 50%• Up to 10 years of zero maintenance
City of Tulsa Case Study (Water Treatment Plant)City of Tulsa Water Plant Cuts Annual Energy Bill by $22K, Saves $10K per Year on Maintenance with Upgrade to Dialight LED Lighting
Installation Snapshot
• Replaced 350 HID, metal halide and T12 fixtures at A.B. Jewell with 259 Dialight LED fixtures including:
• 446,576 kWh saved• $22,300 annual energy savings• $32,000 utility incentive• $10,000 per year saved on lighting maintenance
Donjon Shipbuilding Case Study (Shipbuilding)Donjon Shipbuilding Replaces 250+ HIDs with Just 79 Dialight LEDs to Achieve “Night & Day” Lighting Improvement & Eliminate Lighting maintenance
Installation Snapshot
• Donjon Shipbuilding 200,000 sq. ft. open air production building and dry dock• 92-foot and 125-foot mounting height• 266 existing 1000w Metal Halides• Replaced with just 79 Dialight 60,000 lumen Vigilant High Bays• Reduced fixture count by 70%• A decade of zero maintenance, backed by 10-year, full performance warranty
MMD Shipping Case Study (Cold Storage)The long-life performance of the Dialight LEDs will significantly reduce MMD’s lighting maintenance needs, which were once a costly and cumbersome exercise
Installation Snapshot
• New installation• (134) 150W LED High Bays w/ occ sensors• (16) 80W LED Low Bays w/ occ sensors
• Delivered light: ~300 lux• Payback: 2 years• 19% return from UK’s Enhanced Capital Allowance (ECA) scheme
Case Study
Dialight Installation Case Studies Hazardous Applications soiutions
Industrial Applications I Case Study
www.dialight.com
Horizontal Well Drillers (Onshore Rig) Horizontal Well Drillers Eliminates Rig Lighting Maintenance, Saves Big on Fuel Bills with Upgrade to Dialight LED Hazardous Location Lighting
Installation Snapshot
• Class I Div 1 and Class I Div 2 • Linear Fixtures
• 500+ Class II Div 2 and general purpose fixtures installed: • Energy rate - $1.00/kWh • Energy savings: at least 60% • Up to 10 years of zero maintenance
LANXESS Case Study (rubber plant) LANXESS choLmws Dialight LED lightii., ,,wvv state-of-the-art facility in Jurong Island, Singapore
Installation Snapshot
• 200,000 sqm new facility • 2,370 LED lighting fixtures for indoor/outdoor process areas and internal roads • 55% energy reduction • Annual power savings 1,150,000kWh / SGD 241,500 • 811 metric tonnes CO2 emissions avoided annuallyl • ROI in 1.5 years for 24 hours operated fixtures • ROI in 3 years for 12 hours operated fixtures
PPL Generation LLC Case Study (Obstruction lighting) Daiighti LED Obstruction Lighting Helps PPL Save Energy, Reduce Maintenance Costs and Meet FAA Regulations
Installation Snapshot
• 2 level 395' Height — 20' Diameter Chimney Stacks • PPL Chimney Stacks — Bangor, PA • All White beacon (6) • Replaces 330W Xenon Strobe
Valero Case Study (Refinery) Dialight's LED lighting h.iiproves safety, reliability and energy efficiency for Valero refinery
Installation Snapshot
• Fewer lighting fixtures needed • Reduced energy consumption and CO2 emissions • Zero maintenance • Improved safety from better quality of light • Cold start capable • Instant on ability • Lower cost of ownership
13
Case Study Industrial Applications| Case Study
www.dialight.com 13
Dialight Installation Case StudiesHazardous Applications Solutions
Horizontal Well Drillers (Onshore Rig)Horizontal Well Drillers Eliminates Rig Lighting Maintenance, Saves Big on Fuel Bills with Upgrade to Dialight LED Hazardous Location Lighting
Installation Snapshot
• Class I Div 1 and Class I Div 2• Linear Fixtures
• 500+ Class II Div 2 and general purpose fixtures installed:• Energy rate - $1.00/kWh• Energy savings: at least 60%• Up to 10 years of zero maintenance
LANXESS Case Study (rubber plant)LANXESS chooses Dialight LED lighting for new state-of-the-art facility in Jurong Island, Singapore
Installation Snapshot
• 200,000 sqm new facility• 2,370 LED lighting fixtures for indoor/outdoor process areas and internal roads• 55% energy reduction• Annual power savings 1,150,000kWh / SGD 241,500• 811 metric tonnes CO2 emissions avoided annually1• ROI in 1.5 years for 24 hours operated fixtures• ROI in 3 years for 12 hours operated fixtures
PPL Generation LLC Case Study (Obstruction lighting)Dialight’s LED Obstruction Lighting Helps PPL Save Energy, Reduce Maintenance Costs and Meet FAA Regulations
Installation Snapshot
• 2 level 395’ Height – 20’ Diameter Chimney Stacks• PPL Chimney Stacks – Bangor, PA• All White beacon (6)• Replaces 330W Xenon Strobe
Valero Case Study (Refinery)Dialight’s LED lighting improves safety, reliability and energy efficiency for Valero refinery
Installation Snapshot
• Fewer lighting fixtures needed• Reduced energy consumption and CO2 emissions• Zero maintenance• Improved safety from better quality of light• Cold start capable• Instant on ability• Lower cost of ownership
Vigilant
Industrial Applications I High Bay
Vigilant® LED High Bay - 60,000Im for Industrial applications
Ratings and Certifications
• UL 1598 • NEVA 4X
• CSA 22 #250 • 10yr full performance warranty
• IP66 • L70 rated for >150,000 hours
"All features not available on every model. Please refer to product part number pages for model specifics.
Mechanical information Specifications Fixture weight: Voltage options: 120 - 277V AC Housing: Copper free aluminum
120 - 277V AC models 59 lbs (27 kg) 347 /480V AC Lens: Tempered glass - UL1598
347 / 480V AC models: 75 lbs (34 kg) Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75 Note that the wire box is installed separately from the housing. This allows single installer for fixtures.
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% 4000K (neutral white) 120-277V wire box = 6.6 lb (3 kg) [mount first] 480V wire box = 22.6 lb (10.3 kg) [mount first] Light fixture (base) = 52.4 lb (23.7 kg) [mount last] Surge protection: 6kV/2 ohm combination wave, as
per IEEE C62.41, line-line and line-ground
Shipping weight: Lumens Wattage Im/W Mounting Heights
120 - 277V AC models 73 lbs (33 kg)
60,000 480 125 100' or lower
480V AC models: 90 lbs (40 kg) 60,000 520 115
Mounting: (1) 3/4" NPT - top Comparison
(4) 3/4" NPT - sides Warranty L70
Dialight High Bay
10yr >150,000
Metal Halide
1 6,000
High Pressure Sodium
1 20,000
Dimensions
1,5.9 14101
2112 15121
24.0 [4161 Dimension are in Inches [mm]
Light Distribution Pattern
-.t
Narrow Pattern
480V AC Models
Top Hat Top Hat Hinge
14 www.dialight.com
Vigilant Industrial Applications| High Bay
14 www.dialight.com
Dimensions
Mechanical informationFixture weight:
120 - 277V AC models 59 lbs (27 kg)
347 / 480V AC models: 75 lbs (34 kg)
ComparisonWarranty L70
Dialight High Bay 10yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Light Distribution Pattern
Narrow Pattern
Lumens Wattage lm/W Mounting Heights60,000 480 125 100’ or lower
60,000 520 115
Dimension are in Inches [mm]
480V AC Models
Top Hat Top Hat Hinge
SpecificationsVoltage options: 120 – 277V AC Housing: Copper free aluminum
347 /480V AC Lens: Tempered glass - UL1598
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% 4000K (neutral white)
Surge protection: 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
*All features not available on every model. Please refer to product part number pages for model specifics.
Vigilant® LED High Bay - 60,000lmfor Industrial applications
Ratings and Certifications
• UL 1598 • NEMA 4X
• CSA 22 #250 • 10yr full performance warranty
• IP66 • L70 rated for >150,000 hours
Note that the wire box is installed separately from the housing. This allows single installer for fixtures.
120-277V wire box = 6.6 lb (3 kg) [mount first]480V wire box = 22.6 lb (10.3 kg) [mount first]Light fixture (base) = 52.4 lb (23.7 kg) [mount last]
Shipping weight:
120 - 277V AC models 73 lbs (33 kg)
480V AC models: 90 lbs (40 kg)
Mounting: (1) 3/4” NPT - top
(4) 3/4” NPT - sides
Vigilant
Vigilant® LED High Bay - 60,000Im Ordering Information and Mounting Accessories
Industrial Applications I High Bay
Light Distribution
Pattern Lens CCT
120 - 277V AC
120 - 277V AC
5000K (cool white)
4000K (neutral white)
Tempered glass Narrow
Tempered glass Narrow
10yr
10yr
5000K (cool white)
4000K (neutral white)
Tempered glass Narrow
Tempered glass Narrow
10yr
10yr
347V AC
347V AC
480V AC Tempered glass Narrow
Tempered glass Narrow
10yr
10yr 480V AC 4000K (neutral white)
5000K (cool white)
HBXH • Hook
H 6XCA B7 2 • 72" long steel safety rope
• 3/32" diameter steel rope with one wire clamps
15 www.dialight.com
Watt LPW Part Number Fixture Lumen
H6UGNC44N-SNNG
H6UGNN44N-SNNG
60,000
60,000
480
480
125
125
H6UGNC54N-SNNG
H6UGNN54N-SNNG
60,000
60,000
520
520
115
115
H6UGNC94N-SNNG
H6UGNN94N-SNNG
60,000
60,000
520
520
115
115
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Variable Dimming Models
Part Number Fixture Lumen
Watt LPW Warranty Voltage CCT Lens Light
Distribution Pattern
120 - 277V AC Models
H6UGNC44D-SNNG
H6UGNN44D-SNNG
60,000
60,000
480
480
125
125
10yr
10yr
120 - 277V AC
120 - 277V AC
5000K (cool white)
4000K (neutral white)
Tempered glass
Tempered glass
Narrow
Narrow
347V AC Models
H6UGNC54D-SNNG
H6UGNN54D-SNNG
60,000
60,000
520
520
115
115
10yr
10yr
347V AC
347V AC
5000K (cool white)
4000K (neutral white)
Tempered glass
Tempered glass
Narrow
Narrow
480V AC Models
H6UGNC94D-SNNG
H6UGNN94D-SNNG
60,000
60,000
520
520
115
115
10yr
10yr
480V AC
480V AC
5000K (cool white)
4000K (neutral white)
Tempered glass
Tempered glass
Narrow
Narrow
All values typical unless othowise staled, Lumen values are typical (tolerance +/- 10%).
Standard Models
120 - 277V AC Models
347V AC Models
480V AC Models
Vigilant Industrial Applications| High Bay
www.dialight.com 15
Vigilant® LED High Bay - 60,000lmOrdering Information and Mounting Accessories
H6XCAB72• 72” long steel safety rope• 3/32” diameter steel rope with one wire
clamps
HBXH• Hook
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Part NumberFixture Lumen
Watt LPW Warranty Voltage CCT LensLight
Distribution Pattern
120 - 277V AC Models
H6UGNC44N-SNNG 60,000 480 125 10yr 120 - 277V AC 5000K (cool white) Tempered glass Narrow
H6UGNN44N-SNNG 60,000 480 125 10yr 120 - 277V AC 4000K (neutral white) Tempered glass Narrow
347V AC Models
H6UGNC54N-SNNG 60,000 520 115 10yr 347V AC 5000K (cool white) Tempered glass Narrow
H6UGNN54N-SNNG 60,000 520 115 10yr 347V AC 4000K (neutral white) Tempered glass Narrow
480V AC Models
H6UGNC94N-SNNG 60,000 520 115 10yr 480V AC 5000K (cool white) Tempered glass Narrow
H6UGNN94N-SNNG 60,000 520 115 10yr 480V AC 4000K (neutral white) Tempered glass Narrow
Part NumberFixture Lumen
Watt LPW Warranty Voltage CCT LensLight
Distribution Pattern
120 - 277V AC Models
H6UGNC44D-SNNG 60,000 480 125 10yr 120 - 277V AC 5000K (cool white) Tempered glass Narrow
H6UGNN44D-SNNG 60,000 480 125 10yr 120 - 277V AC 4000K (neutral white) Tempered glass Narrow
347V AC Models
H6UGNC54D-SNNG 60,000 520 115 10yr 347V AC 5000K (cool white) Tempered glass Narrow
H6UGNN54D-SNNG 60,000 520 115 10yr 347V AC 4000K (neutral white) Tempered glass Narrow
480V AC Models
H6UGNC94D-SNNG 60,000 520 115 10yr 480V AC 5000K (cool white) Tempered glass Narrow
H6UGNN94D-SNNG 60,000 520 115 10yr 480V AC 4000K (neutral white) Tempered glass Narrow
Variable Dimming Models
Standard Models
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Mechanical information
Vigilant
Industrial Applications I High Bay
Vigilant® H2 Series LED High Bay for Industrial applications
• UL 1598/A
• CSA 22 #250
• NEMA 4X
Ratings and Certifications
• IP66
• 10yr full performance warranty
• L70 rated for >150,000 hours
"Al features not available on every model. Please refer to product part number pages for model specifics.
Specifications
Fixture weight:
Shipping weight:
Mounting:
Cabling:
18 lbs Voltage options: 110 - 277V AC Housing: Copper free aluminum
24 lbs 347 / 480V AC Lens: Tempered glass - UL1598
(1) 3/4" NPT - top Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
(2) 5/16"-18 x .75" UNC Power factor: >0.9 CCT: 5000K (cool white) - side THD: <20% CCT: 5000K (cool white) 10' (3.05m) STOOW Power Cord
Surge protection: Protection devices capable of handling up to 61&. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
Comparison
Warranty L70 Lumens
25,250 Dialight High Bay 10yr >150,000
25,250 Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Wattage
180
192
Im/W Mounting Heights
140 50' + and Lower
132
115.00 [406.40i
1.88
Dimensions
1.95 [49.53)
3.00 1[76.20]
MIr IP 0 5/16--18x.75"
1.106.40.1 'WEAVED [2)
Dimension are in Inches [mm]
Control Options
Light Distribution Paffern
Dimming
Circular Pattern
16 www.dialight.com
Vigilant Industrial Applications| High Bay
16 www.dialight.com
Dimensions
Ratings and Certifications
• UL 1598/A • IP66
• CSA 22 #250 • 10yr full performance warranty
• NEMA 4X • L70 rated for >150,000 hours
ComparisonWarranty L70
Dialight High Bay 10yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Light Distribution Pattern
Circular Pattern
Lumens Wattage lm/W Mounting Heights
25,250 180 140 50’ + and Lower
25,250 192 132
Control Options
Dimming
Dimension are in Inches [mm]
Mechanical informationFixture weight: 18 lbs
Shipping weight: 24 lbs
Mounting: (1) 3/4” NPT - top
(2) 5/16”-18 x .75” UNC - side
Cabling:10’ (3.05m) STOOW Power Cord
SpecificationsVoltage options: 110 - 277V AC Housing: Copper free aluminum
347 / 480V AC Lens: Tempered glass - UL1598
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% CCT: 5000K (cool white)
Surge protection: Protection devices capable of handling up to 6kV. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
*All features not available on every model. Please refer to product part number pages for model specifics.
Vigilant® H2 Series LED High Bayfor Industrial applications
Vigilant
Industrial Applications I High Bay
Vigilant® H2 Series LED High Bay Ordering Information and Mounting Accessories
Part Number Fixture Lumen
Watt LPW Wet Location
Voltage CCT Light
Distribution Pattern
Standard Models
H2GMC4NN-SNG 25,250 180
H2GMC5NN-SNG 25,250 200
H2GMC5NN-SNG 25,250 192
140
126
132
IP66 110 - 277V AC
IP66 347V AC
IP66 480V AC
5000K (cool white) Tempered glass
5000K (cool white) Tempered glass
5000K (cool white) Tempered glass
Circular
Circular
Circular
Variable Dimming Models
H2GMC4ND-SNG 25,250 180 140 IP66 110 - 277V AC 5000K (cool white) Tempered glass Circular
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%) For models needing a Safety Bracket, replace the 10th character with a S. Example H2GMC4NN-SNG becomes H2GMC4NN-SSG
HBXW3-SSL-316 HBXW3-SSL-304 • Stainless Steel Bracket
HBXCAB48 • 48" long stainless steel
safety rope (for use with safety bracket)
HBXDC • 21° slope dust cover
HBXDC45 • 45° slope dust cover
HBXDC60 • 60° slope dust cover
HBXW3-SSL-304FT • 304 Stainless steel forward
throw bracket
HBXTH347480 • Top hat with 347-480V AC
step down transformer (consult factory when using with hook or loop)
HBXH • Hook
HBXW2 • Swivel bracket and cable
gland
HBXW3 • Swivel bracket
HBXL • Loop
HBXDUALBRCKT • Dual bracket
HBXCU • Ceiling / wall mount
HBXLENGC • Clear tempered glass
HBXLENPC • Polycarbonate lens, clear
HBXLENAC • Acrylic lens, clear
www.dialight.com 17
Vigilant Industrial Applications| High Bay
www.dialight.com 17
HBXW3-SSL-316HBXW3-SSL-304• Stainless Steel Bracket
HBXCU• Ceiling / wall mount
HBXL• Loop
HBXH• Hook
HBXW2• Swivel bracket and cable
gland
HBXW3• Swivel bracket
HBXTH347480• Top hat with 347-480V AC
step down transformer (consult factory when using with hook or loop)
HBXDUALBRCKT• Dual bracket
HBXCAB48• 48” long stainless steel
safety rope (for use with safety bracket)
HBXDC• 21o slope dust cover
HBXDC45• 45o slope dust cover
HBXDC60• 60o slope dust cover
HBXLENGC• Clear tempered glass
HBXLENPC• Polycarbonate lens, clear
HBXLENAC• Acrylic lens, clear
Vigilant® H2 Series LED High BayOrdering Information and Mounting Accessories
HBXW3-SSL-304FT• 304 Stainless steel forward
throw bracket
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%)For models needing a Safety Bracket, replace the 10th character with a S. Example H2GMC4NN-SNG becomes H2GMC4NN-SSG
Part NumberFixture Lumen
Watt LPWWet
LocationVoltage CCT Lens
Light Distribution
Pattern
Standard Models
H2GMC4NN-SNG 25,250 180 140 IP66 110 - 277V AC 5000K (cool white) Tempered glass Circular
H2GMC5NN-SNG 25,250 200 126 IP66 347V AC 5000K (cool white) Tempered glass Circular
H2GMC5NN-SNG 25,250 192 132 IP66 480V AC 5000K (cool white) Tempered glass Circular
Variable Dimming Models
H2GMC4ND-SNG 25,250 180 140 IP66 110 - 277V AC 5000K (cool white) Tempered glass Circular
Fixture weight:
Shipping weight:
Mounting:
Cabling:
18 lbs
24 lbs
(1) 3/4" NPT - top
(4) 3/4" NPT - sides
10' (3.05m) STOOW Power Cord
Voltage options:
110 - 277V AC
100 - 277V AC
120 - 277V AC
Operating temp:
Power factor:
THD:
Surge protection:
14LMS¢ I dl)T.1*1
]Ix nal -11502: -
I I Uti
4.- I NO, I
..suanniff %lithium! 44 .1.1 ll
Dimension are in Inches [mm]
1.58
1.95
3,00 [7.15;20
11.104...10.1
5+16"-18x 75-11-11EACED112)
[406.401
Vigilant
Vigilant® LED High Bay for Industrial applications
Mechanical information
Industrial Applications I High Bay
Ratings and Certifications
• UL 1598/A
• Dark Sky Compliant
• CSA 22 #250
• 10yr full performance warranty
• NEMA 4X
• L70 rated for >150,000 hours
• IP66
"All features not available on every model. Please refer to product part number pages for model specifics.
Specifications
26,5001m models
18,000, 14,000 & 11,000lm models
Occupancy models
-40°F to +149°F (-40°C to +65°C)
>0.9
<20%
Protection devices capable of handling up to 6kV. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
Housing:
Lens:
CRI:
CCT:
Copper free aluminum
Tempered glass - UL1598
75
5000K (cool white)
4000K (neutral white)
Dialight High Bay
Metal Halide
High Pressure Sodium
Comparison Warranty
10yr
1
1
Lumens Wattage Im/W Mounting Heights
L70 26,500 212 125 50' + >150,000 18,000 144 125
6,000 14,000 112 125 20,000 11,000 88 125 20'
Dimension*
Control Options
Light Distribution Pattern
1 "failliffitO Oil II AMP
Occupancy Sensor
Dimming
DALI or Wireless Controls
Circular Pattern
Wide Pattern
18 www.dialight.com
Vigilant Industrial Applications| High Bay
18 www.dialight.com
Vigilant® LED High Bayfor Industrial applications
Lumens Wattage lm/W Mounting Heights
26,500 212 125 50’ +
18,000 144 125
14,000 112 125
11,000 88 125 20’
Dimensions
Light Distribution Pattern
Plane & ConeCATALOG NUMBER: 1ST PRODUCTION UNIT
FILENAME: MIDHIGHBAY 25.IES
MAX CANDLEPOWER: 11359.6 Max plane at H = 45 Max cone at V = 30
Reported data calculated from manufacturer's data file, based on IESNA recommended methods.
Photometric Viewer v3.4
Circular Pattern Wide Pattern
Control Options
Occupancy Sensor Dimming DALI or Wireless Controls
Dimension are in Inches [mm]
Ratings and Certifications
• UL 1598/A • Dark Sky Compliant
• CSA 22 #250 • 10yr full performance warranty
• NEMA 4X • L70 rated for >150,000 hours
• IP66
Mechanical information
Fixture weight: 18 lbs
Shipping weight: 24 lbs
Mounting: (1) 3/4” NPT - top
(4) 3/4” NPT - sides
Cabling: 10’ (3.05m) STOOW Power Cord
ComparisonWarranty L70
Dialight High Bay 10yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Specifications
Voltage options:
110 – 277V AC 26,500lm models Housing: Copper free aluminum
100 – 277V AC 18,000, 14,000 & 11,000lm models Lens: Tempered glass - UL1598
120 - 277V AC Occupancy models CRI: 75
Operating temp: -40°F to +149°F (-40°C to +65°C) CCT: 5000K (cool white)
Power factor: >0.9 4000K (neutral white)
THD: <20%
Surge protection: Protection devices capable of handling up to 6kV. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
*All features not available on every model. Please refer to product part number pages for model specifics.
Vigilant
Industrial Applications I High Bay
Vigilant® LED High Bay Ordering Information and Mounting Accessories
Part Number Fixture Lumen Watt LPW Wet Location Voltage CCT Lens Light Distribution
Standard Models
HEGMC4PN-SNG 26,500 212 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4PN-SNG 26,500 212 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Wide
HEGEC4PN-SNG 25,750 204 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Aisle
HEGNC4PN-SNG 26,500 212 125 IP66 110 -277V AC 5000K (cool white) Tempered glass Narrow
HEGMC4KN-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4KN-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGEC4KN-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HEGNC4KN-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Narrow
HEGMC4GN-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4GN-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGEC4GN-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HEGNC4GN-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Narrow
HEGMC4DN-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4DN-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGEC4DN-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HEGNC4DN-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Narrow
Occupancy Sensor Models
HEGMC1PM-SNG 26,500 212 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC1PM-SNG 26,500 212 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC1KM-SNG 18,000 144 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC1KM-SNG 18,000 144 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC1GM-SNG 14,000 112 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC1GM-SNG 14,000 112 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC1DM-SNG 11,000 88 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC1DM-SNG 11,000 88 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Wide
Variable Dimming Models
HEGMC4PD-SNG 26,500 212 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4PD-SNG 26,500 212 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4KD-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4KD-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4GD-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4GD-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4DD-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4DD-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Al models shown in the table are Cool White, for models in Neutral White, 4000K CCT, replace the 5th character with an N. Ex: HEGMC4PN-SNG becomes HEGMN4PN-SNG. Deduct 5% from lumen values when specify neutral. For models needing a Safety Bracket, replace the 10th character with a S. Example HEGMC4PN-SNG becomes HEGMC4PN-SSG. Al models show in the above table come with an internal fuse. For models needing an external fuse, replace the 10th character with an F. Ex: HEGMC4PN-SNG becomes HEGMC4PN-SFG. (Fixture will be listed damp location only with internal fuse). For models needing both Safety Bracket & Fuse, replace the 10th character with an G. Ex: HEGMC4PN-SNG becomes HEGMC4PN-SGG. Part numbers with occupancy sensor that will be installed with Hook or Loop (HBXH or HBXL) accessories will require a counter balance installed prior to shipment. Replace the 10th character with an C. Ex: HEGMC4PN-SNG becomes HEGMC4PN-SCG. Part numbers listed in the tables above come with a glass lens. For models needing a poycarbonate dome lens, replace the 3rd character with an L, Ex: HEGMC4PN-SNG becomes HELMC4PN-SNG. For models needing a flat poycarbonate lens, replace the 3rd character with a 2, Ex: HEGMC4PN-SNG becomes HE2MC4PN-SNG. For models needing a flat acrylic lens, replace the 3rd character with an 1, Ex: HEGMC4PN-SNG becomes HE1MC4PN-SNG. Dome & acrylic lens not available on power wash models, please use glass or flat poycarbonate.
www.dialight.com
19
Vigilant Industrial Applications| High Bay
www.dialight.com 19
Vigilant® LED High BayOrdering Information and Mounting Accessories
Part Number Fixture Lumen Watt LPW Wet Location Voltage CCT Lens Light Distribution
Standard Models
HEGMC4PN-SNG 26,500 212 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4PN-SNG 26,500 212 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Wide
HEGEC4PN-SNG 25,750 204 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Aisle
HEGNC4PN-SNG 26,500 212 125 IP66 110 -277V AC 5000K (cool white) Tempered glass Narrow
HEGMC4KN-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4KN-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGEC4KN-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HEGNC4KN-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Narrow
HEGMC4GN-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4GN-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGEC4GN-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HEGNC4GN-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Narrow
HEGMC4DN-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4DN-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGEC4DN-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HEGNC4DN-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Narrow
Occupancy Sensor Models
HEGMC1PM-SNG 26,500 212 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC1PM-SNG 26,500 212 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC1KM-SNG 18,000 144 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC1KM-SNG 18,000 144 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC1GM-SNG 14,000 112 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC1GM-SNG 14,000 112 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC1DM-SNG 11,000 88 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC1DM-SNG 11,000 88 125 IP65 120 - 277V AC 5000K (cool white) Tempered glass Wide
Variable Dimming Models
HEGMC4PD-SNG 26,500 212 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4PD-SNG 26,500 212 125 IP66 110 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4KD-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4KD-SNG 18,000 144 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4GD-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4GD-SNG 14,000 112 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4DD-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4DD-SNG 11,000 88 125 IP66 100 - 277V AC 5000K (cool white) Tempered glass Wide
All models shown in the table are Cool White, for models in Neutral White, 4000K CCT, replace the 5th character with an N. Ex: HEGMC4PN-SNG becomes HEGMN4PN-SNG. Deduct 5% from lumen values when specifying neutral.For models needing a Safety Bracket, replace the 10th character with a S. Example HEGMC4PN-SNG becomes HEGMC4PN-SSG.All models show in the above table come with an internal fuse. For models needing an external fuse, replace the 10th character with an F. Ex: HEGMC4PN-SNG becomes HEGMC4PN-SFG.(Fixture will be listed damp location only with internal fuse).For models needing both Safety Bracket & Fuse, replace the 10th character with an G. Ex: HEGMC4PN-SNG becomes HEGMC4PN-SGG.Part numbers with occupancy sensor that will be installed with Hook or Loop (HBXH or HBXL) accessories will require a counter balance installed prior to shipment. Replace the 10th character with an C.Ex: HEGMC4PN-SNG becomes HEGMC4PN-SCG.Part numbers listed in the tables above come with a glass lens. For models needing a polycarbonate dome lens, replace the 3rd character with an L, Ex: HEGMC4PN-SNG becomes HELMC4PN-SNG. For models needing a flat polycarbonate lens, replace the 3rd character with a 2, Ex: HEGMC4PN-SNG becomes HE2MC4PN-SNG. For models needing a flat acrylic lens, replace the 3rd character with an 1, Ex: HEGMC4PN-SNG becomes HE1MC4PN-SNG. Dome & acrylic lens not available on power wash models, please use glass or flat polycarbonate.
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
HBXCAB48 • 48" long stainless steel
safety rope (for use with safety bracket)
HBXTH347480 • Top hat with 347-480V AC
step down transformer
HBXL • Loop
HBXREF22 • 22" Acrylic reflector (must
be ordered with high bay, not a retrofit option)
LBXLENP • Polycarbonate dome lens
replacement
HBXDC • 21° slope dust cover
HBXDC45 • 45° slope dust cover
HBXDC60 • 60° slope dust cover
HBXH • Hook
HBXDUALBRCKT • Dual bracket
HBXCG • Cable gland
Vigilant
Industrial Applications I High Bay
Vigilant® LED High Bay Ordering Information and Mounting Accessories
Part Number Fixture Lumen Watt LPW Wet Location Voltage CCT Lens Light Distribution
Powerwash Models
HEGMC4PN-SPG 26,500 212 125 1000 PSI 110 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4PN-SPG 26,500 212 125 1000 PSI 110 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4KN-SPG 18,000 144 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4KN-SPG 18,000 144 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4GN-SPG 14,000 112 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4GN-SPG 14,000 112 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4DN-SPG 11,000 88 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4DN-SPG 11,000 88 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Wide
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Al models shown in the table are Cool White, for models in Neutral White, 4000K CCT, replace the 5th character with an N. Ex: HEGMCAPN-SNG becomes HEGMN4PN-SNG. Deduct 5% from lumen values when specify neutral. For models needing a Safety Bracket, replace the 10th character with an S. Example HEGMC4PN-SNG becomes HEGMC4RN-SiG. Al models show in the above table come with an internal fuse. For models needing an external fuse, replace the 10th character with a F. Ex: HEGMC4PN-SNG becomes HEGMC4PN-SFG. (Fixture will be listed damp location ony with internal fuse). For models needing both Safety Bracket & Fuse, replace the 10th character with an 0. Ex: HEGMC4PN-SNG becomes HEGMC4RN-SOG. Part numbers with occupancy sensor that will be installed with Hook or Loop (HBXH or HBXL) accessories will require a counter balance installed prior to shipment. Replace the 10th character with an C. Ex: HEGMC4PN-SNG becomes HEGMC4PN-SCG. Part numbers listed in the tables above come with a glass lens. For models needing a poycarbonate dome lens, replace the 3rd character with an L, Ex: HEGMC4RN-SNG becomes HELMC4PN-SNG. For models needing a flat polycarbonate lens, replace the 3rd character with a 2, Ex: HEGMC4RN-SNG becomes HE2MC4PN-SNG. For models needing a flat acrylic lens, replace the 3rd character with an 1, Ex: HEOMC4RN-SNG becomes HE1MC4PN-SNG. Dome & acrylic lens not available on power wash models, please use glass or flat polycarbonate.
HBXW3-SSL-316 HBXW3-SSL-304 • Stainless steel bracket
HBXW3-SSL-304FT • 304 Stainless steel forward
throw bracket
HBXW2 • Swivel bracket and cable
gland
HBXW3 • Swivel bracket
HBXCU • Ceiling / wall mount
HBXLENGC • Clear tempered glass
HBXLENPC • Polycarbonate lens, clear
HBXLENAC • Acrylic lens, clear
20
www.dialight.com
Vigilant Industrial Applications| High Bay
20 www.dialight.com
All models shown in the table are Cool White, for models in Neutral White, 4000K CCT, replace the 5th character with an N. Ex: HEGMC4PN-SNG becomes HEGMN4PN-SNG. Deduct 5% from lumen values when specifying neutral.For models needing a Safety Bracket, replace the 10th character with an S. Example HEGMC4PN-SNG becomes HEGMC4PN-SSG.All models show in the above table come with an internal fuse. For models needing an external fuse, replace the 10th character with a F. Ex: HEGMC4PN-SNG becomes HEGMC4PN-SFG.(Fixture will be listed damp location only with internal fuse).For models needing both Safety Bracket & Fuse, replace the 10th character with an G. Ex: HEGMC4PN-SNG becomes HEGMC4PN-SGG.Part numbers with occupancy sensor that will be installed with Hook or Loop (HBXH or HBXL) accessories will require a counter balance installed prior to shipment. Replace the 10th character with an C.Ex: HEGMC4PN-SNG becomes HEGMC4PN-SCG.Part numbers listed in the tables above come with a glass lens. For models needing a polycarbonate dome lens, replace the 3rd character with an L, Ex: HEGMC4PN-SNG becomes HELMC4PN-SNG. For models needing a flat polycarbonate lens, replace the 3rd character with a 2, Ex: HEGMC4PN-SNG becomes HE2MC4PN-SNG. For models needing a flat acrylic lens, replace the 3rd character with an 1, Ex: HEGMC4PN-SNG becomes HE1MC4PN-SNG. Dome & acrylic lens not available on power wash models, please use glass or flat polycarbonate.
Part Number Fixture Lumen Watt LPW Wet Location Voltage CCT Lens Light Distribution
Powerwash Models
HEGMC4PN-SPG 26,500 212 125 1000 PSI 110 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4PN-SPG 26,500 212 125 1000 PSI 110 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4KN-SPG 18,000 144 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4KN-SPG 18,000 144 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4GN-SPG 14,000 112 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4GN-SPG 14,000 112 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Wide
HEGMC4DN-SPG 11,000 88 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Medium
HEGRC4DN-SPG 11,000 88 125 1000 PSI 100 - 277V AC 5000K (cool white) Tempered glass Wide
HBXW3-SSL-316HBXW3-SSL-304• Stainless steel bracket
HBXCU• Ceiling / wall mount
HBXL• Loop
HBXH• Hook
HBXW2• Swivel bracket and cable
gland
HBXW3• Swivel bracket
HBXTH347480• Top hat with 347-480V AC
step down transformer
HBXDUALBRCKT• Dual bracket
HBXCAB48• 48” long stainless steel
safety rope (for use with safety bracket)
HBXDC• 21o slope dust cover
HBXDC45• 45o slope dust cover
HBXDC60• 60o slope dust cover
HBXW3-SSL-304FT• 304 Stainless steel forward
throw bracket
HBXLENGC• Clear tempered glass
HBXLENPC• Polycarbonate lens, clear
HBXLENAC• Acrylic lens, clear
HBXCG• Cable gland
HBXREF22• 22” Acrylic reflector (must
be ordered with high bay, not a retrofit option)
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Vigilant® LED High BayOrdering Information and Mounting Accessories
LBXLENP• Polycarbonate dome lens
replacement
Vigilant Industrial Applications I High Bay
Vigilant® LED High Bay 480V AC Passive Power Supply for Industrial application!
Mechanical information
Fixture weight: 40 lbs (18 kg)
Shipping weight: 45 lbs (20 kg)
Mounting: (1) 3/4" NPT - top
(2) 5/16"-18 x .75" UNC - side
Cabling: 10' (3.5m) STOOW Power cord
Ratings and Certifications
• UL 1598/A
• CSA 22 #250
• IP66
• Dark Sky Compliant
• 10yr full performance warranty
• L70 rated for >150,000 hours
Voltage options:
"AI features not available on every model. Please refer to product part number pages for model specifics.
Specifications
480V AC, 60Hz
Operating temp: -40°F to +149°F (-40°C to +65°C) Housing: Copper free aluminum
Power factor: >0.9 Lens: Tempered glass - UL1598
THD: <20% CRI: 75
Surge protection: 6kV/2 Ohm combination wave, as per IEEE CCT: 5000K (cool white)
C62.41, line-line and line-ground
Comparison Lumens Wattage Im/W Mounting Heights
Warranty L70 26,500 212 125 50' and lower Dialight High Bay 10yr >150,000 18,000 144 125
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Dimensions
ISLA [33 I. 3j
/-0 eiolg •
so
Me - &LIS- DREADED FOE 112.1
a 5116-18 Lt DRODED PACILDITNG It 4:KeT *CIES
Dimension are in Inches [mm]
Light Distribution Pattern
Circular Pattern
www.dialight.com
21
Vigilant Industrial Applications| High Bay
www.dialight.com 21
Dimensions
Light Distribution Pattern
Circular Pattern
Dimension are in Inches [mm]
Ratings and Certifications
• UL 1598/A
• CSA 22 #250
• IP66
• Dark Sky Compliant
• 10yr full performance warranty
• L70 rated for >150,000 hours
Comparison
Warranty L70
Dialight High Bay 10yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Lumens Wattage lm/W Mounting Heights
26,500 212 125 50’ and lower
18,000 144 125
Mechanical information
Fixture weight: 40 lbs (18 kg)
Shipping weight: 45 lbs (20 kg)
Mounting: (1) 3/4” NPT - top
(2) 5/16”-18 x .75” UNC - side
Cabling:10’ (3.5m) STOOW Power cord
Specifications
Voltage options: 480V AC, 60Hz
Operating temp: -40°F to +149°F (-40°C to +65°C) Housing: Copper free aluminum
Power factor: >0.9 Lens: Tempered glass - UL1598
THD: <20% CRI: 75
Surge protection: 6kV/2 Ohm combination wave, as per IEEE
C62.41, line-line and line-ground
CCT: 5000K (cool white)
*All features not available on every model. Please refer to product part number pages for model specifics.
Vigilant® LED High Bay 480V AC Passive Power Supplyfor Industrial applications
Vigilant
Industrial Applications I High Bay
Vigilant® LED High Bay 480V AC Passive Power Supply Ordering Information and Mounting Accessories
Part Number Fixture Lumens
Watt Lumens Per Watt CCT
Wet Locations
Voltage Lens Optical Pattern
Circular Wide
Standard Models
HEGMCPPN-SNG 26,500 212 125 5000K (cool white) IP66 480V AC Tempered glass
HEGMCPKN-SNG 18,000 144 125 5000K (cool white) IP66 480V AC Tempered glass
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
HLXW2 • Swivel bracket and cable
gland
HLXW3 • Swivel bracket
HBXL • Loop
HBXH • Hook
HBXCU • Ceiling / wall mount
HBXLENGC • Clear tempered glass
HBXCG • Cable gland
22
www.dialight.com
Vigilant Industrial Applications| High Bay
22 www.dialight.com
HBXCU• Ceiling / wall mount
HBXL• Loop
HBXH• Hook
HLXW2• Swivel bracket and cable
gland
HLXW3• Swivel bracket
HBXLENGC• Clear tempered glass
HBXCG• Cable gland
Vigilant® LED High Bay 480V AC Passive Power SupplyOrdering Information and Mounting Accessories
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Part NumberFixture
LumensWatt
LumensPer Watt
CCTWet
LocationsVoltage Lens
Optical Pattern
Circular Wide
Standard Models
HEGMCPPN-SNG 26,500 212 125 5000K (cool white) IP66 480V AC Tempered glass •
HEGMCPKN-SNG 18,000 144 125 5000K (cool white) IP66 480V AC Tempered glass •
Vigilant Industrial Applications I Floodlight
Im/W
129 125
130
Wattage
424 424
288
Mounting Heights
50' +
Medium Distribution Nema 6 Distribution
Vigilant® LED Dual Floodlight for Industrial application
Voltage options: 120 - 277V AC Housing: Copper free aluminum
347V AC Lens: Tempered glass
480V AC CRI: 75
Operating temp: -40°F to +149°F (-40°C to +65°C) CCT: 5000K (cool white)
Power factor: >0.9
THD: <20%
Surge protection: 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
Comparison Lumens Warranty L70 55,000
Dialight Floodlight 10yr >150,000 53,000 Metal Halide 1 6,000 37,500 High Pressure Sodium 1 20,000
Dimensions
1.0.3
120 - 277V AC models
323182101
Dimensions
Dimension are in Inches [mm]
Light Distribution
www.dialight.com 23
Fixture weight:
Shipping weight:
EPA (Sq.ft):
Mounting:
Entries:
56 lb (23 kg)
60 lb (27 kg)
2.69
304 Stainless Steel trunnion mounting bracket included
(2) 3/4" NPT cable entries
• UL 1598
• C22.2 No.250
• IP66
Mechanical information
Ratings and Certifications
• 10yr full performance warranty
• L70 rated for >150,000 hours
• IK07
"Al features not available on every model. Please refer to product part number pages for model specifics.
Specifications
Vigilant Industrial Applications| Floodlight
www.dialight.com 23
Dimensions
120 - 277V AC models Dimensions
Light Distribution
Medium Distribution Nema 6 Distribution
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
55,000 424 129 50’ +
53,000 424 125
37,500 288 130
Ratings and Certifications
• UL 1598 • 10yr full performance warranty
• C22.2 No.250 • L70 rated for >150,000 hours
• IP66 • IK07
Mechanical information
Fixture weight: 56 lb (23 kg)
Shipping weight: 60 lb (27 kg)
EPA (Sq.ft): 2.69
Mounting:304 Stainless Steel trunnion mounting bracket included
Entries: (2) 3/4” NPT cable entries
ComparisonWarranty L70
Dialight Floodlight 10yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Specifications
Voltage options: 120 – 277V AC Housing: Copper free aluminum
347V AC Lens: Tempered glass
480V AC CRI: 75
Operating temp: -40°F to +149°F (-40°C to +65°C) CCT: 5000K (cool white)
Power factor: >0.9
THD: <20%
Surge protection: 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
*All features not available on every model. Please refer to product part number pages for model specifics.
Vigilant® LED Dual Floodlightfor Industrial applications
Standard Models - 347 / 480V AC
Part Number Fixture Lumens
Wattage Lumens Per Watt Voltage CCT Lens
347V AC 480V AC 347V AC 480V AC
FLWB66NC5NG 55,000 496 448 111 123 347 / 480V AC 5000K (cool white)
FLWBMONCSNG 53,000 496 448 107 118 347 / 480V AC 5000K (cool white)
FLW966NC5NG 37,500 360 312 104 120 347 / 480V AC 5000K (cool white)
Tempered glass
Tempered glass
Tempered glass
Light Distribution
Pattern
NEMA 6
Medium
NEMA 6
Vigilant
Industrial Applications I Floodlight
Vigilant® LED Dual Floodlight Ordering Information and Mounting Accessories
Standard Models - 120 - 277V AC
Part Number Fixture Lumens Wattage Lumens Per Watt Voltage CCT Lens
FLWB66NC2NG 55,000
FLWBMONC2NG 53,000
FLW966NC2NG 37,500
424 129 120-277V AC
120-277V AC
120-277V AC
5000K (cool white) Tempered glass
424 125 5000K (cool white) Tempered glass
288 130 5000K (cool white) Tempered glass
ig Distribution
NEMA 6
Medium
NEMA 6
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
HZXCBL2 • Safety cable Kit
FLX-1TPT-2013131 • Tenon pole topper, 2-3/8" mount
'Bracket and Adapters below require Tenon adapter (FLX-1TPT-20DB) to mount floodlight. Tenon adapter is sold separatey
FLX-3RPA-20DB • Reducer for 3" OD
round pole top to 2-3/8" light mount
FLX-4RPA-20DB • Reducer for 4" OD round
pole top to 2-3/8" light mount
FLX-4SPA-20DB • Internal tenon adapter for 4" square pole top to
2-3/8" light mount
FLX-5SPA-20D3 • Internal tenon adapter for 5" square pole
top to 2-3/8" light mount
FLX-6SPA-20D3 • Internal tenon adapter for 6" square pole top to
2-3/8" light mount
24
www.dialight.com
Vigilant Industrial Applications| Floodlight
24 www.dialight.com
1Bracket and Adapters below require Tenon adapter (FLX-1TPT-20DB) to mount floodlight. Tenon adapter is sold separately
Vigilant® LED Dual FloodlightOrdering Information and Mounting Accessories
FLX-3RPA-20DB• Reducer for 3” OD
round pole top to 2-3/8” light mount
FLX-4RPA-20DB• Reducer for 4” OD round
pole top to 2-3/8” light mount
FLX-1TPT-20DB1
• Tenon pole topper, 2-3/8” mount
HZXCBL2• Safety cable Kit
FLX-4SPA-20DB• Internal tenon adapter for 4” square pole top to
2-3/8” light mount
FLX-5SPA-20DB• Internal tenon adapter for 5” square pole
top to 2-3/8” light mountFLX-6SPA-20DB• Internal tenon adapter for 6” square pole top to
2-3/8” light mount
Part Number Fixture Lumens Wattage Lumens Per Watt Voltage CCT Lens
Light Distribution
PatternFLWB66NC2NG 55,000 424 129 120-277V AC 5000K (cool white) Tempered glass NEMA 6
FLWBM0NC2NG 53,000 424 125 120-277V AC 5000K (cool white) Tempered glass Medium
FLW966NC2NG 37,500 288 130 120-277V AC 5000K (cool white) Tempered glass NEMA 6
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Part Number Fixture Lumens
Wattage Lumens Per WattVoltage CCT Lens
Light Distribution
Pattern347V AC 480V AC 347V AC 480V AC
FLWB66NC5NG 55,000 496 448 111 123 347 / 480V AC 5000K (cool white) Tempered glass NEMA 6
FLWBM0NC5NG 53,000 496 448 107 118 347 / 480V AC 5000K (cool white) Tempered glass Medium
FLW966NC5NG 37,500 360 312 104 120 347 / 480V AC 5000K (cool white) Tempered glass NEMA 6
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Standard Models - 120 - 277V AC
Standard Models - 347 / 480V AC
Vigilant Industrial Applications I Controls
LED High Bay Ratings and Certifications
• Dark Sky Compliant
• 10yr full performance warranty
• L70 rated for >150,000 hours
• UL 1598/A
• CSA 22 #250
• NEMA 4X
• IP66
High Bay Mechanical information
Fixture weight:
Shipping weight:
Mounting:
18 lbs (8.16kg)
24 lbs (10.8kg)
(1) 3/4" NPT - top
(2) 5/16"-18 x .75" UNC - side
10' (3.5m) STOOW Power Cord
High Bay Specifications
Housing: Lens: CRI:
CCT:
26,5001m models
18,000, 14,000 & 11,0001m models
-40°F to +149°F (-40°C to +65°C)
>0.9
<20%
Voltage options: 110 - 277V AC
100 - 277V AC
Operating temp:
Power factor:
THD:
Surge protection:
Housing: Voltage options: Operating temp: Network Adapter:
Protection devices capable of handling up to 61&. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
Controller Specifications
Copper free aluminum, plastic available (consult factory) 120 - 277V AC -40°C to +65°C RJ45 10/100MB Ethernet port
Im/W
124
124
125
124
Wattage
213
145
113
89
LED High Bay Dimensions Controller Dimensions
Circular Pattern Wide Pattern
Vigilant® LED High Bay with DALI or Wireless Controls for Industrial application!
"Al features not available on every model. Please refer to product part number pages for model specifics.
Lumens
L70 26,500
>150,000 18,000 6,000 14,000 20,000 11,000
Copper free aluminum Tempered glass - UL1598 75
5000K (cool white)
4000K (neutral white)
Mounting Heights
50' +
20'
.5k5 1149.431
3.00
5/1 6"- 1 ak 75" ThIPEADED (211
1406.40]
14.06.4.0]
FROW Ll111111111 6. ri
[76.201
Dimension are in Inches [mm]
Light Distribution Pattern
www.dialight.com 25
Controller Mechanical information
Fixture weight: 71bs (4kg)
Shipping weight: 12 lbs (14kg)
Four (4) .25in (6.35mm) Mounting: flat surface wall mounting
screw holes
RJ45 10/100MB Ethernet port
Cabling:
Cabling:
Dialight High Bay
Metal Halide
High Pressure Sodium
Comparison Warranty
10yr
1
1
*4 '1,h 1211 019
17G1101.3
Vigilant Industrial Applications| Controls
www.dialight.com 25
LED High Bay Dimensions Controller Dimensions
Dimension are in Inches [mm]
LED High Bay Ratings and Certifications
• UL 1598/A • Dark Sky Compliant
• CSA 22 #250 • 10yr full performance warranty
• NEMA 4X • L70 rated for >150,000 hours
• IP66
Comparison
Warranty L70
Dialight High Bay 10yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
High Bay Mechanical information
Fixture weight: 18 lbs (8.16kg)
Shipping weight: 24 lbs (10.8kg)
Mounting: (1) 3/4” NPT - top
(2) 5/16”-18 x .75” UNC - side
Cabling:10’ (3.5m) STOOW Power Cord
High Bay Specifications
Voltage options: Housing: Copper free aluminum
110 – 277V AC 26,500lm models Lens: Tempered glass - UL1598
100 – 277V AC 18,000, 14,000 & 11,000lm models CRI: 75
Operating temp: -40°F to +149°F (-40°C to +65°C) CCT: 5000K (cool white)
Power factor: >0.9 4000K (neutral white)
THD: <20%
Surge protection:Protection devices capable of handling up to 6kV. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
Controller Specifications
Housing: Copper free aluminum, plastic available (consult factory)
Voltage options: 120 – 277V AC
Operating temp: -40°C to +65°C
Network Adapter: RJ45 10/100MB Ethernet port
Light Distribution Pattern
Plane & ConeCATALOG NUMBER: 1ST PRODUCTION UNIT
FILENAME: MIDHIGHBAY 25.IES
MAX CANDLEPOWER: 11359.6 Max plane at H = 45 Max cone at V = 30
Reported data calculated from manufacturer's data file, based on IESNA recommended methods.
Photometric Viewer v3.4
Circular Pattern Wide Pattern
Controller Mechanical information
Fixture weight: 7lbs (4kg)
Shipping weight: 12 lbs (14kg)
Mounting:Four (4) .25in (6.35mm) flat surface wall mounting screw holes
Cabling:RJ45 10/100MB Ethernet port
Lumens Wattage lm/W Mounting Heights
26,500 213 124 50’ +
18,000 145 124
14,000 113 125
11,000 89 124 20’
*All features not available on every model. Please refer to product part number pages for model specifics.
Vigilant® LED High Bay with DALI or Wireless Controlsfor Industrial applications
Vigilant Industrial Applications I Controls
Vigilant® LED High Bay with DALI or Wireless Controls Ordering Information and Mounting Accessories
Part number Fixture
Lumens Wattage
Lumens per Watt
Voltage CCT Wet
Location Lens Optics
Vigilant LED High Bay - Jennet 2.4GHz
HEGMC4PJ-SNG 26,500 213 124 110 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4PJ-SNG 26,500 213 124 110 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
HEGMC4KJ-SNG 18,000 145 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4KJ-SNG 18,000 145 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
HEGMC4GJ-SNG 14,000 113 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4GJ-SNG 14,000 113 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
HEGMC4DJ-HNG 11,000 89 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
Vigilant LED High Bay - DALI Protocol
HEGMC4PA-SNG 26,500 213 124 110 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4PA-SNG 26,500 213 124 110 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
HEGMC4KA-SNG 18,000 145 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4KA-SNG 18,000 145 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
High Bay Gateway - DALI & Jennet
WLC-004-MBAL 10W typical, 20W max 120 - 277V AC Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
26 www.dialight.com
Vigilant Industrial Applications|Controls
26 www.dialight.com
Part number1,2Fixture
LumensWattage
Lumens per Watt
Voltage CCTWet
LocationLens Optics
Vigilant LED High Bay - Jennet 2.4GHz
HEGMC4PJ-SNG 26,500 213 124 110 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4PJ-SNG 26,500 213 124 110 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
HEGMC4KJ-SNG 18,000 145 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4KJ-SNG 18,000 145 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
HEGMC4GJ-SNG 14,000 113 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4GJ-SNG 14,000 113 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
HEGMC4DJ-HNG 11,000 89 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
Vigilant LED High Bay - DALI Protocol
HEGMC4PA-SNG 26,500 213 124 110 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4PA-SNG 26,500 213 124 110 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
HEGMC4KA-SNG 18,000 145 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Circular
HEGRC4KA-SNG 18,000 145 124 100 - 277V AC 5000K (cool white) IP66 Tempered glass Wide
High Bay Gateway - DALI & Jennet
WLC-004-MBAL 10W typical, 20W max 120 - 277V AC
Vigilant® LED High Bay with DALI or Wireless ControlsOrdering Information and Mounting Accessories
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Vigilant Industrial Applications I Controls
Wireless Occupancy Sensor for Industrial applications
Hiah Bay Mechanical information Fixture weight: 10 oz (283 g)
Shipping weight: 18 oz (510 g)
Mounting plate (comes with sensor)
10' (3.5m) STOOW Power Cord
LED High Bay Ratings and Certifications • UL 916 • CSA 22.2 #205
• CE • IP66
• 5yr full performance warranty
"Al features not available on every model. Please refer to product part number pages for model specifics.
High Bay Specifications Voltage options: 3.3V via 2 - AA Lithium Batteries Housing: UV stabilized poycarbonate
Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Fresnel
Mounting:
Cabling:
Mounting Options
12 miers or 10.5 fe:t.. . . 41111.
The long range sensor is best used as a wall mounted sensor. The recommended install for this sensor is 3.2 meters or 10.5 feet from the floor
Avoid placing sensors where obstacles can block the sensors line of sight.
Part number Voltage Lens
WOSU12BG
3.3V via 2 - AA lithium batteries
Fresnel
www.dialight.com
27
Vigilant Industrial Applications| Controls
www.dialight.com 27
Wireless Occupancy Sensorfor Industrial applications
Mounting Options
The long range sensor is best used as a wall mounted sensor. The recommended install for this sensor is 3.2 meters or 10.5 feet from the floor
Avoid placing sensors where obstacles can block the sensors line of sight.
LED High Bay Ratings and Certifications
• UL 916 • CSA 22.2 #205
• CE • IP66
• 5yr full performance warranty
High Bay Mechanical information
Fixture weight: 10 oz (283 g)
Shipping weight: 18 oz (510 g)
Mounting:Mounting plate (comes with sensor)
Cabling:10’ (3.5m) STOOW Power Cord
High Bay Specifications
Voltage options: 3.3V via 2 – AA Lithium Batteries Housing: UV stabilized polycarbonate
Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Fresnel
*All features not available on every model. Please refer to product part number pages for model specifics.
Part number Voltage Lens
WOSU12BG 3.3V via 2 – AA lithium batteries Fresnel
Comparison Warranty
Dialight High Bay 5 / 10yr Metal Halide 1
High Pressure Sodium 1
Circular Pattern • Aisle Pattern
Dimensions
.86
Occupancy Sensor
Control Options
Dimming DALI or Wireless Controls
Light Distribution Patterns.
P.95 10'
[3.05m] Card
1406,40]
3,00
rain* 11111111111.11 MN
16,00 5/16-.18x. 75' [406.40] THREADED (2)
Dimension are in Inches [mm]
(49,53)
[76.20]
DuroSite
Industrial Application I High Bay
DuroSite® LED High Bay for Industrial applications
'Ianical information
Ratings and Certifications
• UL 1598/A
• DLC listed • CE
• ABS • CSA 22 #250
• 5yr full performance warranty • NEMA 4X
• 10yr full performance warranty • IP66
• L70 rated for >150,000 hours "AI features not available on every model. Please refer to product part number pages for model specifics.
Specifications
Housing: Lens:
17 lbs (7.7 kg)
23 lbs (10.43 kg)
(1) 3/4" NPT - top
(2) 5/16"-18 x .75" UNC - side
10' (3.05m) STOOW Power Cord
Voltage options: 100 - 277V AC 347 - 480V AC
Operating temp: -40°F to +149°F (-40°C to +65°C) Power factor: >0.9 THD: <20%
CRI:
Surge protection: Verified up to 6kV/2ohms at an CCT:
independent test laboratory
Copper free aluminum Tempered glass - UL 1598A wet location Polycarbonate - UL 1598A wet location Acrylic - UL 1598 dry location >70
5000K (cool white)
4000K (neutral white)
Fixture weight:
Shipping weight:
Mounting:
Cabling:
Lumens Wattage Im/W Mounting Heights L70 17,500 170 103 50
>150,000 15,000 146 103 6,000 13,500 150 90 20,000 10,500 146 72
8,500 124 69 20'
28 www.dialight.com
DuroSite Industrial Application| High Bay
28 www.dialight.com
Dimensions
Light Distribution Patterns
Circular Pattern Aisle Pattern
Dimension are in Inches [mm]
Control Options
Occupancy Sensor Dimming DALI or Wireless Controls
Lumens Wattage lm/W Mounting Heights
17,500 170 103 50
15,000 146 103
13,500 150 90
10,500 146 72
8,500 124 69 20’
Ratings and Certifications
• UL 1598/A • DLC listed
• CE • ABS
• CSA 22 #250 • 5yr full performance warranty
• NEMA 4X • 10yr full performance warranty
• IP66 • L70 rated for >150,000 hours
Mechanical information
Fixture weight: 17 lbs (7.7 kg)
Shipping weight: 23 lbs (10.43 kg)
Mounting: (1) 3/4” NPT - top
(2) 5/16”-18 x .75” UNC - side
Cabling: 10’ (3.05m) STOOW Power Cord
ComparisonWarranty L70
Dialight High Bay 5 / 10yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
347 - 480V AC Lens: Tempered glass - UL 1598A wet location
Operating temp: -40°F to +149°F (-40°C to +65°C) Polycarbonate - UL 1598A wet location
Power factor: >0.9 Acrylic - UL 1598 dry location
THD: <20% CRI: >70
Surge protection: Verified up to 6kV/2ohms at an independent test laboratory
CCT: 5000K (cool white)
4000K (neutral white)
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED High Bayfor Industrial applications
MICE Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Polycarbonate
Tempered glass
Tempered glass
Acrylic
Acrylic
Polycarbonate
Polycarbonate
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Acrylic
Polycarbonate
Polycarbonate
Polycarbonate dome
Polycarbonate dome
Polycarbonate dome
Polycarbonate
Acrylic
Polycarbonate dome
Polycarbonate dome
Acrylic
Acrylic
Polycarbonate dome
Polycarbonate dome
Polycarbonate
Polycarbonate dome
Polycarbonate dome
Polycarbonate dome
Polycarbonate
Polycarbonate
Wide
Circular
Circular
Circular
Circular
Aisle
Aisle
Circular
Circular
Circular
Circular
Circular
Circular
Circular
Circular
Circular
Circular
Wide
Circular
Circular
Circular
Circular
Circular
Circular
Circular
Aisle
Aisle
Circular
Circular
Circular
Circular
Circular
Circular
Lens
Optical Pattern
I
Diffused
Aisle
Aisle
Aisle
Aisle
DuroSite
Industrial Application I High Bay
DuroSite® LED High Bay Ordering Information and Mounting Accessories
Part Number Fixture
Wattage LPW Warranty Voltage CCT Lumen
Standard Models - 100 - 277V AC
HBEC4P 13,500 146 90 10yr 100 - 277V AC 5000K (cool white)
HBEC4P 13,500 150 90 10yr 100 - 277V AC 5000K (cool white)
HB6C4M 11,750 146 80 5yr 100 - 277V AC 5000K (cool white)
HB7C4M 11,750 146 80 5yr 100 - 277V AC 5000K (cool white)
HBWC4L 8,500 107 79 10yr 100 - 277V AC 5000K (cool white)
Standard Models - 347 - 480V AC
HBLCTP 15,500 172 90 5yr 347 - 480V AC 5000K (cool white)
HBGCSP 14,500 161 87 5yr 347 - 480V AC 5000K (cool white)
HBLCSP 14,500 161 90 5yr 347 - 480V AC 5000K (cool white)
HB2C5P 12,500 161 78 5yr 347 - 480V AC 5000K (cool white)
HB7C5M 11,750 146 80 5yr 347 - 480V AC 5000K (cool white)
HB6C5M 11,750 146 80 5yr 347 - 480V AC 5000K (cool white)
HBOCSP 11,500 161 72 5yr 347 - 480V AC 5000K (cool white)
HB1C5N 11,500 146 79 5yr 347 - 480V AC 5000K (cool white)
HB1C5J 11,000 146 75 5yr 347 - 480V AC 5000K (cool white)
HB2C5M 10,750 146 74 5yr 347 - 480V AC 5000K (cool white)
HB5C5M 10,750 146 74 5yr 347 - 480V AC 5000K (cool white)
HBLCSM 10,750 146 74 5yr 347 - 480V AC 5000K (cool white)
HBLCSK 10,500 146 72 5yr 347 - 480V AC 5000K (cool white)
HB2C5K 10,500 146 72 5yr 347 - 480V AC 5000K (cool white)
HB5C5J 10,500 146 72 5yr 347 - 480V AC 5000K (cool white)
HB3C5L 9,000 124 73 5yr 347 - 480V AC 5000K (cool white)
HBWCSL 8,750 140 62 5yr 347 - 480V AC 5000K (cool white)
HBLCSL 8,500 124 69 5yr 347 - 480V AC 5000K (cool white)
HB4C5L 8,500 124 69 5yr 347 - 480V AC 5000K (cool white)
Standard Models - 120 - 250V DC
HBGCYP 17,000 172 99 5yr 120 - 250V DC 5000K (cool white)
HBLCYP 15,000 172 87 5yr 120 - 250V DC 5000K (cool white)
HBGCDP 14,000 161 87 5yr 120 - 250V DC 5000K (cool white)
HBLCDP 12,500 161 78 5yr 120 - 250V DC 5000K (cool white)
HBGCDN 12,000 146 98 5yr 120 - 250V DC 5000K (cool white)
HB6CDM 11,750 146 80 5yr 120 - 250V DC 5000K (cool white)
HB7CDM 11,750 146 80 5yr 120 - 250V DC 5000K (cool white)
HB1CDN 11,500 146 79 5yr 120 - 250V DC 5000K (cool white)
HB2CDM 10,750 146 74 5yr 120 - 250V DC 5000K (cool white)
HB2CDK 10,500 146 72 5yr 120 - 250V DC 5000K (cool white)
HBLCDK 10,000 146 68 5yr 120 - 250V DC 5000K (cool white)
HBOCDK 9,750 146 67 5yr 120 - 250V DC 5000K (cool white)
HB4CDL 8,500 124 69 5yr 120 - 250V DC 5000K (cool white)
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
www.dialight.com
29
DuroSite Industrial Application| High Bay
www.dialight.com 29
Part NumberFixture Lumen
Wattage LPW Warranty Voltage CCTLens Optical
PatternClear Diffused
Standard Models - 100 - 277V AC
HBEC4P 13,500 146 90 10yr 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HBEC4P 13,500 150 90 10yr 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HB6C4M 11,750 146 80 5yr 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HB7C4M 11,750 146 80 5yr 100 - 277V AC 5000K (cool white) Tempered glass Aisle
HBWC4L 8,500 107 79 10yr 100 - 277V AC 5000K (cool white) Polycarbonate dome Wide
Standard Models - 347 - 480V AC
HBLCTP 15,500 172 90 5yr 347 - 480V AC 5000K (cool white) Polycarbonate dome Circular
HBGC5P 14,500 161 87 5yr 347 - 480V AC 5000K (cool white) Tempered glass Circular
HBLC5P 14,500 161 90 5yr 347 - 480V AC 5000K (cool white) Polycarbonate dome Circular
HB2C5P 12,500 161 78 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
HB7C5M 11,750 146 80 5yr 347 - 480V AC 5000K (cool white) Tempered glass Aisle
HB6C5M 11,750 146 80 5yr 347 - 480V AC 5000K (cool white) Tempered glass Aisle
HB0C5P 11,500 161 72 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
HB1C5N 11,500 146 79 5yr 347 - 480V AC 5000K (cool white) Acrylic Circular
HB1C5J 11,000 146 75 5yr 347 - 480V AC 5000K (cool white) Acrylic Circular
HB2C5M 10,750 146 74 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
HB5C5M 10,750 146 74 5yr 347 - 480V AC 5000K (cool white) Acrylic Circular
HBLC5M 10,750 146 74 5yr 347 - 480V AC 5000K (cool white) Polycarbonate dome Circular
HBLC5K 10,500 146 72 5yr 347 - 480V AC 5000K (cool white) Polycarbonate dome Circular
HB2C5K 10,500 146 72 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
HB5C5J 10,500 146 72 5yr 347 - 480V AC 5000K (cool white) Acrylic Circular
HB3C5L 9,000 124 73 5yr 347 - 480V AC 5000K (cool white) Acrylic Circular
HBWC5L 8,750 140 62 5yr 347 - 480V AC 5000K (cool white) Polycarbonate dome Wide
HBLC5L 8,500 124 69 5yr 347 - 480V AC 5000K (cool white) Polycarbonate dome Circular
HB4C5L 8,500 124 69 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
Standard Models - 120 - 250V DC
HBGCYP 17,000 172 99 5yr 120 - 250V DC 5000K (cool white) Tempered glass Circular
HBLCYP 15,000 172 87 5yr 120 - 250V DC 5000K (cool white) Polycarbonate dome Circular
HBGCDP 14,000 161 87 5yr 120 - 250V DC 5000K (cool white) Tempered glass Circular
HBLCDP 12,500 161 78 5yr 120 - 250V DC 5000K (cool white) Polycarbonate dome Circular
HBGCDN 12,000 146 98 5yr 120 - 250V DC 5000K (cool white) Tempered glass Circular
HB6CDM 11,750 146 80 5yr 120 - 250V DC 5000K (cool white) Tempered glass Aisle
HB7CDM 11,750 146 80 5yr 120 - 250V DC 5000K (cool white) Tempered glass Aisle
HB1CDN 11,500 146 79 5yr 120 - 250V DC 5000K (cool white) Acrylic Circular
HB2CDM 10,750 146 74 5yr 120 - 250V DC 5000K (cool white) Polycarbonate Circular
HB2CDK 10,500 146 72 5yr 120 - 250V DC 5000K (cool white) Polycarbonate Circular
HBLCDK 10,000 146 68 5yr 120 - 250V DC 5000K (cool white) Polycarbonate dome Circular
HB0CDK 9,750 146 67 5yr 120 - 250V DC 5000K (cool white) Polycarbonate Circular
HB4CDL 8,500 124 69 5yr 120 - 250V DC 5000K (cool white) Polycarbonate Circular
DuroSite® LED High BayOrdering Information and Mounting Accessories
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Light Distribution Pattern
Lens
Diffused
Circular
Polycarbonate dome
Circular
Aisle
Aisle
Aisle
Circular
Circular
Circular
Circular
Circular
Acrylic
Circular
Circular
Circular
Polycarbonate
Circular
Polycarbonate
Circular
30
HBXDC HBXCAB48 • 21° slope dust cover • 48" long stainless steel HBXDC45
safety rope (for use with • 45° slope dust cover safety bracket) HBXDC60
• 60° slope dust cover
HBXTH 347480 • Top hat with 347-480V AC
step down transformer (consult factory when using with hook or loop)
HBXL • Loop
HBXREF22 • 22" Acrylic reflector (must
be ordered with high bay, not a retrofit option)
HBXH • Hook
HBXDUALBRCKT • Dual bracket
HBXCG • Cable gland
DuroSite
Industrial Application I High Bay
DuroSite® LED High Bay Ordering Information and Mounting Accessories
Part Number Fixture Lumen
Wattage LPW Warranty Voltage CCT Clear
Occupancy Sensor Models - 347 - 480V AC
HBGC8T 14,000 161 87 5yr 347 - 480V AC 5000K (cool white) Tempered glass
HBLC8T 10,750 146 74 5yr 347 - 480V AC 5000K (cool white)
HB6C8T 11,750 146 80 5yr 347 - 480V AC 5000K (cool white) Tempered glass
HB7C7T 11,750 146 80 5yr 347 - 480V AC 5000K (cool white) Tempered glass
HB7C8T 11,750 146 80 5yr 347 - 480V AC 5000K (cool white) Polycarbonate
HB1C8T 11,500 146 79 5yr 347 - 480V AC 5000K (cool white) Acrylic
HB1C7S 11,500 146 79 5yr 347 - 480V AC 5000K (cool white) Acrylic
HB1C8S 11,500 146 79 5yr 347 - 480V AC 5000K (cool white) Acrylic
HB2C7T 10,750 146 74 5yr 347 - 480V AC 5000K (cool white) Polycarbonate
HB2C8T 10,750 146 74 5yr 347 - 480V AC 5000K (cool white) Polycarbonate
HB5C7S 10,500 146 72 5yr 347 - 480V AC 5000K (cool white)
HB2C7S 10,500 146 72 5yr 347 - 480V AC 5000K (cool white) Polycarbonate
HB2C8S 10,500 146 72 5yr 347 - 480V AC 5000K (cool white) Polycarbonate
HB4C7R 8,500 124 69 5yr 347 - 480V AC 5000K (cool white)
HB4C8R 8,500 124 69 5yr 347 - 480V AC 5000K (cool white)
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
HBXW2 • Swivel bracket and cable
gland
HBXW3 • Swivel bracket
HBXCU • Ceiling / wall mount
HBXLENGC HBXLEN PC • Clear tempered glass • Polycarbonate lens, clear
HBXLENAC HBXLENPD • Acrylic lens, clear • Polycarbonate lens,
HBXLENAD diffused
• Acrylic lens, diffused
HBXW3-SSL-31 6 HBXW3-SSL-304 • Stainless steel bracket
FLX1 HBXSS • 304 Stainless steel forward
throw bracket
www.dialight.com
DuroSite Industrial Application| High Bay
30 www.dialight.com
Part NumberFixture Lumen
Wattage LPW Warranty Voltage CCTLens Light Distribution
PatternClear Diffused
Occupancy Sensor Models - 347 - 480V AC
HBGC8T 14,000 161 87 5yr 347 - 480V AC 5000K (cool white) Tempered glass Circular
HBLC8T 10,750 146 74 5yr 347 - 480V AC 5000K (cool white) Polycarbonate dome Circular
HB6C8T 11,750 146 80 5yr 347 - 480V AC 5000K (cool white) Tempered glass Aisle
HB7C7T 11,750 146 80 5yr 347 - 480V AC 5000K (cool white) Tempered glass Aisle
HB7C8T 11,750 146 80 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Aisle
HB1C8T 11,500 146 79 5yr 347 - 480V AC 5000K (cool white) Acrylic Circular
HB1C7S 11,500 146 79 5yr 347 - 480V AC 5000K (cool white) Acrylic Circular
HB1C8S 11,500 146 79 5yr 347 - 480V AC 5000K (cool white) Acrylic Circular
HB2C7T 10,750 146 74 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
HB2C8T 10,750 146 74 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
HB5C7S 10,500 146 72 5yr 347 - 480V AC 5000K (cool white) Acrylic Circular
HB2C7S 10,500 146 72 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
HB2C8S 10,500 146 72 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
HB4C7R 8,500 124 69 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
HB4C8R 8,500 124 69 5yr 347 - 480V AC 5000K (cool white) Polycarbonate Circular
DuroSite® LED High BayOrdering Information and Mounting Accessories
HBXW3-SSL-316HBXW3-SSL-304• Stainless steel bracket
HBXCU• Ceiling / wall mount
HBXL• Loop
HBXH• Hook
HBXW2• Swivel bracket and cable
gland
HBXW3• Swivel bracket
HBXTH347480• Top hat with 347-480V AC
step down transformer (consult factory when using with hook or loop)
HBXDUALBRCKT• Dual bracket
HBXCAB48• 48” long stainless steel
safety rope (for use with safety bracket)
HBXDC• 21o slope dust cover
HBXDC45• 45o slope dust cover
HBXDC60• 60o slope dust cover
FLX1HBXSS• 304 Stainless steel forward
throw bracket
HBXLENGC• Clear tempered glass
HBXLENAC• Acrylic lens, clear
HBXLENAD• Acrylic lens, diffused
HBXLENPC• Polycarbonate lens, clear
HBXLENPD• Polycarbonate lens,
diffused
HBXCG• Cable gland
HBXREF22• 22” Acrylic reflector (must
be ordered with high bay, not a retrofit option)
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
DuroSite Industrial Application I High Bay
Housing: Lens: CRI: CCT:
Copper free aluminum Tempered glass - UL 1598A wet location >70 5000K (cool white) 4000K (neutral white)
Im/W
90 82
Comparison Warranty
10yr 1 1
Lumens
25,000 22,250
Wattage 270 270
Mounting Heights
50' and lower L70 >150,000
6,000 20,000
Dialight High Bay Metal Halide High Pressure Sodium
Clear Diffused
Circular HLGCDKN10YR 25,000 270 93 10yr 120 - 250V DC 5000K (cool white) Tempered glass Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
31 www.dialight.com
DuroSite® LED 25,000Im High Bay for Industrial application!
Mechanical information
• UL 1598/A • CSA 22 #250 • NEMA 4X (pending) • IP66
"Al features not available on every model. specifics.
Specifications
• ABS • 10yr full performance warranty • L70 rated for >150,000 hours
Ratings and Certifications
Rease refer to product part number pages for model
Fixture weight:
Shipping weight:
Mounting:
Cabling:
30 lbs (13.6 kg)
35 lbs (15.88 kg)
(1) 3/4" NPT - top
(2) 5/16"-18 x .75" UNC - side
10' (3.05m) STOOW Power Cord
Voltage options:
Operating temp: Power factor: THD:
Surge protection:
100 - 277V AC 347 - 480V AC -40°F to +149°F (-40°C to +65°C)
>0.9 <20%
Verified up to 10kV/2ohms at an independent test laboratory
Light Distribution Patterns
Part Number Optical Pattern
Lens
HBXCU • Ceiling /wall mount
HBXCG
• Cable Gland
HBXL
• Loop
HBXLENGC
• Clear tempered glass
HLXW2
• Swivel bracket and cable gland
HLXW3
• Swivel bracket
HBXH
• Hook
Fixture Lumen
Dimensions
solo 9LecIl.REACCI hiCuNliNG IMCKET HMS
Dimension are in Inches [mm]
WM? ullEADED101.121
!IN ,a1
_ - -
Circular Pattern
Wattage LPW Warranty
Voltage
CCT
DuroSite Industrial Application| High Bay
www.dialight.com 31
Dimensions Light Distribution Patterns
Circular PatternDimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
25,000 270 90 50’ and lower
22,250 270 82
Ratings and Certifications
• UL 1598/A • ABS
• CSA 22 #250 • 10yr full performance warranty
• NEMA 4X (pending) • L70 rated for >150,000 hours
• IP66
Mechanical information
Fixture weight: 30 lbs (13.6 kg)
Shipping weight: 35 lbs (15.88 kg)
Mounting: (1) 3/4” NPT - top
(2) 5/16”-18 x .75” UNC - side
Cabling:10’ (3.05m) STOOW Power Cord
ComparisonWarranty L70
Dialight High Bay 10yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
347 - 480V AC Lens: Tempered glass - UL 1598A wet location
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: >70
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% 4000K (neutral white)
Surge protection:Verified up to 10kV/2ohms at an independent test laboratory
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED 25,000lm High Bayfor Industrial applications
Part NumberFixture Lumen
Wattage LPW Warranty Voltage CCTLens Optical
PatternClear Diffused
HLGCDKN10YR 25,000 270 93 10yr 120 - 250V DC 5000K (cool white) Tempered glass Circular
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
HBXCU• Ceiling / wall mount
HBXL• Loop
HBXH• Hook
HBXLENGC• Clear tempered glass
HLXW2• Swivel bracket and
cable gland
HLXW3• Swivel bracket
HBXCG• Cable Gland
hanical information
Fixture weight:
Shipping weight:
Mounting:
18 lbs (8.2 kg)
24 lbs (10.92 kg)
(1) 3/4" NPT - top
(2) 5/16"-18 x .75" UNC - side
Cabling:
10' (3.05m) STOOW Power Cord
18.26 r112..81 ?lits.06
e5.4i
Dimension are in Inches [mm]
Control Options
Light Distribution Pattern
Occupancy Sensor Dimming
DuroSite
DuroSite® LED Low Bay for Industrial applications
Industrial Application I Low Bay
Ratings and Certifications
• UL 1598/A
• DLC listed • UL 8750
• CSA 22 #250 • IP66
• 5/10yr full performance warranty • NEMA 4X
• L70 rated for >150,000 hours "All features not available on every model. Please refer to product part number pages for model specifics.
Specifications
Voltage options:
Operating temp: Power factor: THD:
Surge protection:
100 - 277V AC Housing: Copper free aluminum 347 - 480V AC Lens: Poycarbonate - UL 1598A wet location -40°F to +149°F (-40°C to +65°C) CRI: 70
>0.9 CCT: 5000K (cool white) <20% 4000K (neutral white)
1 kV line to line, 2 kV line to ground
Lumens Wattage Im/W Comparison Mounting Heights Warranty L70 8,750 140 62 20'
Dialight Low Bay 5yr >150,000 6,000 80 75
Metal Halide 1 6,000 20,000 3,800 45 84 10' High Pressure Sodium 1
Dimensions
32 www.dialight.com
DuroSite Industrial Application| Low Bay
32 www.dialight.com
Dimensions
Control Options
Occupancy Sensor Dimming
Light Distribution Pattern
Wide Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
8,750 140 62 20’
6,000 80 75
3,800 45 84 10’
Ratings and Certifications
• UL 1598/A • DLC listed
• UL 8750 • CSA 22 #250
• IP66 • 5/10yr full performance warranty
• NEMA 4X • L70 rated for >150,000 hours
Mechanical information
Fixture weight: 18 lbs (8.2 kg)
Shipping weight: 24 lbs (10.92 kg)
Mounting: (1) 3/4” NPT - top
(2) 5/16”-18 x .75” UNC - side
Cabling: 10’ (3.05m) STOOW Power Cord
ComparisonWarranty L70
Dialight Low Bay 5yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
347 - 480V AC Lens: Polycarbonate - UL 1598A wet location
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 70
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% 4000K (neutral white)
Surge protection: 1 kV line to line, 2 kV line to ground
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED Low Bayfor Industrial applications
HBXW2 • Swivel bracket and cable
gland
HBXW3 • Swivel bracket
HBXL • Loop
HBXH • Hook
HBXCU • Ceiling / wall mount
LBXLENP • Polycarbonate dome lens
replacement
) HBXCG • Cable Gland
DuroSite
Industrial Application I Low Bay
DuroSite® LED Low Bay Ordering Information and Mounting Accessories
Part Number Fixture Lumen Wattage LPVV Warranty Voltage CCT Lens
Optical Pattern
Standard Models - 100 - 277V AC
HBWC4L 8,500 107 79 10yr 100 - 277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C1D 6,000 80 75 5yr 100 - 277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C1D-10YR 5,500 70 79 10yr 100 - 277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C1A 3,800 45 84 5yr 100 - 277V AC 5000K (cool white) Polycarbonate dome Wide
Standard Models - 347 - 480V AC
HBWCSL 8,500 107 79 5yr 347-480V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C7D 6,000 80 75 5yr 347-480V AC 5000K (cool white) Polycarbonate dome Wide
Occupancy Sensor Models - 120 - 277V AC
LBW1C2D 6,000 80 75 5yr 120-277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C2A 3,800 45 84 5yr 120-277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C2ACB 3,800 45 84 5yr 120-277V AC 5000K (cool white) Polycarbonate dome Wide
Variable Dimming Models - 100 - 277V AC
LBW1C5D 6,000 80 75 5yr 100-277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C5A 3,800 45 84 5yr 100-277V AC 5000K (cool white) Polycarbonate dome Wide
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
www.dialight.com 33
DuroSite Industrial Application| Low Bay
www.dialight.com 33
DuroSite® LED Low BayOrdering Information and Mounting Accessories
HBXCU• Ceiling / wall mount
HBXL• Loop
HBXH• Hook
HBXW2• Swivel bracket and cable
gland
HBXW3• Swivel bracket
LBXLENP• Polycarbonate dome lens
replacement
HBXCG• Cable Gland
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Part NumberFixture Lumen
Wattage LPW Warranty Voltage CCT LensOptical Pattern
Standard Models - 100 - 277V AC
HBWC4L 8,500 107 79 10yr 100 - 277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C1D 6,000 80 75 5yr 100 - 277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C1D-10YR 5,500 70 79 10yr 100 - 277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C1A 3,800 45 84 5yr 100 - 277V AC 5000K (cool white) Polycarbonate dome Wide
Standard Models - 347 - 480V AC
HBWC5L 8,500 107 79 5yr 347-480V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C7D 6,000 80 75 5yr 347-480V AC 5000K (cool white) Polycarbonate dome Wide
Occupancy Sensor Models - 120 - 277V AC
LBW1C2D 6,000 80 75 5yr 120-277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C2A 3,800 45 84 5yr 120-277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C2ACB 3,800 45 84 5yr 120-277V AC 5000K (cool white) Polycarbonate dome Wide
Variable Dimming Models - 100 - 277V AC
LBW1C5D 6,000 80 75 5yr 100-277V AC 5000K (cool white) Polycarbonate dome Wide
LBW1C5A 3,800 45 84 5yr 100-277V AC 5000K (cool white) Polycarbonate dome Wide
Comparison Warranty
10yr 1 1
L70 >100,000
6,000 20,000
Dialight Floodlight Metal Halide
High Pressure Sodium
13051343i
104
3.0 269
Dimension are in Inches [mm]
0.4 ill
17_2
DuroSite
Industrial Application I Floodlight
DuroSite® LED Floodlight for Industrial applications
Ratings and Certifications
• UL 1598/A • IK07 • C22.2 No.250 • 10yr full performance warranty • CE • L70 rated for >100,000 hours • IP66/67 • NEMA 4X
"Al features not available on every model. Please refer to product part number pages for model specifics.
Mechanical information Specifications
Fixture weight: 30 lbs (13.6 kg) Voltage options: Housing: Copper free aluminum Shipping weight: 34 lb (16 kg) 100 - 277V AC Die Cast Copper free aluminum Lens: Tempered glass EPA (Sq.tt): 0.55 sq.ft 347 - 487V AC Sand Cast Copper free aluminum CRI: 75
Cabling: 304 Stainless Steel trunnion mounting bracket included
Operating temp: Power factor:
-40°F to +149°F (-40°C to +65°C)
>0.9 CCT: 5000K (cool white)
Entry: (2) 3/4" NPT cable entry THD: <20%
Surge protection: IEC 61000-4-5 6kV line-to-line , 6kV line-to-ground
Lumens Wattage Im/W Mounting Heights
15,000 130 115 30' 14,750 130 113
13,500 140 96 11,500 109 105 11,250 109 103 11,000 109 101 10,750 109 99 10,500 109 96 15'
Dimensions
Light Distribution Patterns
NEMA 7x6
NEMA 6x7
NEMA 6
NEMA 5
NEMA 4
NEMA 2 Field angle=1400x 115° Field angle= 15°x 140°
Field angle = 1150
Field angle = 93°
Field angle = 520
Field angle = 230
34
www.dialight.com
DuroSite Industrial Application| Floodlight
34 www.dialight.com
Lumens Wattage lm/W Mounting Heights
15,000 130 115 30’
14,750 130 113
13,500 140 96
11,500 109 105
11,250 109 103
11,000 109 101
10,750 109 99
10,500 109 96 15’
Dimensions
Light Distribution Patterns
NEMA 7x6Field angle=140o x 115o
NEMA 6x7Field angle= 15o x 140o
NEMA 6Field angle = 115o
NEMA 5Field angle = 93o
NEMA 4Field angle = 52o
NEMA 2Field angle = 23o
Dimension are in Inches [mm]
Ratings and Certifications
• UL 1598/A • IK07
• C22.2 No.250 • 10yr full performance warranty
• CE • L70 rated for >100,000 hours
• IP66/67 • NEMA 4X
Mechanical information
Fixture weight: 30 lbs (13.6 kg)
Shipping weight: 34 lb (16 kg)
EPA (Sq.ft): 0.55 sq.ft
Cabling: 304 Stainless Steel trunnion mounting bracket included
Entry: (2) 3/4” NPT cable entry
ComparisonWarranty L70
Dialight Floodlight 10yr >100,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Specifications
Voltage options: Housing: Copper free aluminum
100 - 277V AC Die Cast Copper free aluminum Lens: Tempered glass
347 - 487V AC Sand Cast Copper free aluminum CRI: 75
Operating temp: -40°F to +149°F (-40°C to +65°C) CCT: 5000K (cool white)
Power factor: >0.9
THD: <20%
Surge protection: IEC 61000-4-56kV line-to-line , 6kV line-to-ground
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED Floodlightfor Industrial applications
DuroSite
Industrial Application I Floodlight
DuroSite® LED Floodlight Ordering Information and Mounting Accessories
Part Number Fixture Lumen
Watt LPW Warranty Voltage Lens CCT Light Distribution
Standard Models - 100 - 277V AC FLW466NC4NG 15,000 130 115 10yr 100-277V AC Tempered glass 5000K (cool white) Very wide (115°) FLW476NC4NG 14,750 130 113 10yr 100-277V AC Tempered glass 5000K (cool white) Asymmetrical (140° x 115°)
FLW467NC4NG 14,750 130 113 10yr 100-277V AC Tempered glass 5000K (cool white) Asymmetrical (115°x 140°) FLW455NC4NG 14,500 140 104 10yr 100-277V AC Tempered glass 5000K (cool white) Wide (93°) FLW444NC4NG 14,500 140 104 10yr 100-277V AC Tempered glass 5000K (cool white) Medium (52°) FLW422NC4NG 13,500 140 96 10yr 100-277V AC Tempered glass 5000K (cool white) Narrow (23°) FLW276NC2NG 11,500 109 105 10yr 100-277V AC Tempered glass 5000K (cool white) Asymmetrical (140° x 115°)
FLW267NC2NG 11,500 109 105 10yr 100-277V AC Tempered glass 5000K (cool white) Asymmetrical (115°x 140°) FLW266NC2NG 11,250 109 103 10yr 100-277V AC Tempered glass 5000K (cool white) Very wide (115°)
FLW255NC2NG 11,000 109 101 10yr 100-277V AC Tempered glass 5000K (cool white) Wide (93°) FLW244NC2NG 10,500 109 96 10yr 100-277V AC Tempered glass 5000K (cool white) Medium (52°)
FLW222NC2NG 10,750 109 99 10yr 100-277V AC Tempered glass 5000K (cool white) Narrow (23°)
Standard Models - 347 - 480V AC FLW276NC5NG 11,750 113 104 10yr 347-480V AC Tempered glass 5000K (cool white) Asymmetrical (140° x 115°)
FLW266NC5NG 11,250 113 100 10yr 347-480V AC Tempered glass 5000K (cool white) Very wide (115°) FLW255NC5NG 10,000 112 89 10yr 347-480V AC Tempered glass 5000K (cool white) Wide (93°) FLW244NC5NG 10,000 112 89 10yr 347-480V AC Tempered glass 5000K (cool white) Medium (52°) FLW222NC5NG 10,000 112 89 10yr 347-480V AC Tempered glass 5000K (cool white) Narrow (23°)
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Part numbers listed in the table above are powder coated gray. For bronze powder, coat replace the 10th character with Z FLW244NC2NG becomes FLW244NC2ZG
FLX-3RPA-20DB • Reducer for 3" OD round
pole top to 2-3/8" light
mount
FLX-4RPA-20DB • Reducer for 4" OD round
pole top to 2-3/8" light mount
HZXCBL2 • Safety cable Kit
FLX-4SPA-20DB • Internal tenon adapter for 4"
square pole top to 2-3/8" light mount
FLX-5SPA-20D3 • 5" square pole top to 2-3/8"
light mount
FLX-6SPA-20D3 • 6" square pole top to 2-3/8"
light mount
FLX-1TPT-20DB • Tenon pole topper,
2-3/8" mount
FLX-2LBH-20DB • Bull horn for 2 lights,
2-3/8" mount, 21" spacing
FLX-4LBH-20DB • Bull horn for 4 lights,
2-3/8" mount, 21" spacing
FLX-1RAB-20DB • Tenon pole topper,
2-3/8" mount
FLX-3LBH-20DB • Bull horn for 3 lights,
2-3/8" mount, 21" spacing
FLX-4RBH-20DB • Bull horn for 4 lights
in star configuration, 2-3/8" mount, 21" spacing
FLX-2RSR-20DB • Round square round
bracket for 2 lights, 2-3/8" mount, 21" spacing
FLX-3RSR-20DB • Round square round
bracket for 3 lights, 2-3/8" mount, 21" spacing
FLX-4RSR-20DB • Round square round
bracket for 4 lights, 2-3/8" mount, 21" spacing
www.dialight.com 35
DuroSite Industrial Application| Floodlight
www.dialight.com 35
Part numbers listed in the table above are powder coated gray. For bronze powder, coat replace the 10th character with Z. FLW244NC2NG becomes FLW244NC2ZG
DuroSite® LED FloodlightOrdering Information and Mounting Accessories
FLX-3RPA-20DB• Reducer for 3” OD round
pole top to 2-3/8” light mount
FLX-4RPA-20DB• Reducer for 4” OD round
pole top to 2-3/8” light mount
FLX-1TPT-20DB• Tenon pole topper,
2-3/8” mount
FLX-2LBH-20DB• Bull horn for 2 lights,
2-3/8” mount, 21” spacing
HZXCBL2• Safety cable Kit
FLX-4SPA-20DB• Internal tenon adapter for 4”
square pole top to 2-3/8” light mount
FLX-5SPA-20DB• 5” square pole top to 2-3/8”
light mount
FLX-6SPA-20DB• 6” square pole top to 2-3/8”
light mount
FLX-1RAB-20DB• Tenon pole topper,
2-3/8” mount
FLX-2RSR-20DB• Round square round
bracket for 2 lights, 2-3/8” mount, 21” spacing
FLX-3LBH-20DB• Bull horn for 3 lights,
2-3/8” mount, 21” spacing
FLX-4RSR-20DB• Round square round
bracket for 4 lights, 2-3/8” mount, 21” spacing
FLX-3RSR-20DB• Round square round
bracket for 3 lights, 2-3/8” mount, 21” spacing
FLX-4LBH-20DB• Bull horn for 4 lights,
2-3/8” mount, 21” spacing
FLX-4RBH-20DB• Bull horn for 4 lights
in star configuration, 2-3/8” mount, 21” spacing
Part NumberFixture Lumen
Watt LPW Warranty Voltage Lens CCT Light Distribution
Standard Models - 100 - 277V ACFLW466NC4NG 15,000 130 115 10yr 100-277V AC Tempered glass 5000K (cool white) Very wide (115°)FLW476NC4NG 14,750 130 113 10yr 100-277V AC Tempered glass 5000K (cool white) Asymmetrical (140o x 115o)FLW467NC4NG 14,750 130 113 10yr 100-277V AC Tempered glass 5000K (cool white) Asymmetrical (115o x 140o)FLW455NC4NG 14,500 140 104 10yr 100-277V AC Tempered glass 5000K (cool white) Wide (93°)FLW444NC4NG 14,500 140 104 10yr 100-277V AC Tempered glass 5000K (cool white) Medium (52°)FLW422NC4NG 13,500 140 96 10yr 100-277V AC Tempered glass 5000K (cool white) Narrow (23°)FLW276NC2NG 11,500 109 105 10yr 100-277V AC Tempered glass 5000K (cool white) Asymmetrical (140o x 115o)FLW267NC2NG 11,500 109 105 10yr 100-277V AC Tempered glass 5000K (cool white) Asymmetrical (115o x 140o)FLW266NC2NG 11,250 109 103 10yr 100-277V AC Tempered glass 5000K (cool white) Very wide (115°)FLW255NC2NG 11,000 109 101 10yr 100-277V AC Tempered glass 5000K (cool white) Wide (93°)FLW244NC2NG 10,500 109 96 10yr 100-277V AC Tempered glass 5000K (cool white) Medium (52°)FLW222NC2NG 10,750 109 99 10yr 100-277V AC Tempered glass 5000K (cool white) Narrow (23°)
Standard Models - 347 - 480V ACFLW276NC5NG 11,750 113 104 10yr 347-480V AC Tempered glass 5000K (cool white) Asymmetrical (140o x 115o)FLW266NC5NG 11,250 113 100 10yr 347-480V AC Tempered glass 5000K (cool white) Very wide (115°)FLW255NC5NG 10,000 112 89 10yr 347-480V AC Tempered glass 5000K (cool white) Wide (93°)FLW244NC5NG 10,000 112 89 10yr 347-480V AC Tempered glass 5000K (cool white) Medium (52°)FLW222NC5NG 10,000 112 89 10yr 347-480V AC Tempered glass 5000K (cool white) Narrow (23°)
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Specifications
Voltage options: Operating temp: Power factor: THD: Surge protection:
120 - 277V AC -40°F to +149°F (-40°C to +65°C)
>0.9 <20% 6 kV line to line, 6 kV line to ground
Housing: Lens: CRI: CCT:
Extruded 6063 aluminum Polycarbonate 80 5000K (cool white) 4000K (neutral white)
al
r
4' Models Dimension are in Inches [mm]
51-W11M 18.31 02121.111
919 p1.11
r 417
i1214
- 15.15 [44]0,1] -
14.212124a.ej
3.58 X1.11
irsli
27.150. p6e7A1 24.31 p17.5)
2' Models
1:31,41 5,12
DuroSite
Industrial Application I Linear
DuroSite® LED End-to-End Linear for Industrial applications
Mechanical information
Fixture weight: 4' linear: 18 lbs (8.16 kg) 2' linear: 13 lbs (5.90 kg)
Shipping weight:
4' linear: 20 lbs (9.07 kg)
2' linear: 15 lbs (6.80 kg)
Mounting: (4) 3/4" NPT openings
Optional ceiling, flush or swivel mounting bracket
Ratings and Certifications
• UL 1598/A
• IP66/67 • CSA 22.2 No. 250.0
• NEMA 4X • 5yr full performance warranty • L70 rated for >125,000 hours
"All features not available on every model. Please refer to product part number pages for model specifics.
Dialight Linear
Metal Halide
High Pressure Sodium
Fluorescent
Im/W
125 113 125
109
Comparison Warranty L70
5yr >125,000 1
6,000 1
20,000 1
24,000
T-Rating
T5 T2
T2A
T3
Lumens
7,500 6,750 4,000 3,500
Wattage
60 60 32 32
Mounting Heights
20'
10'
Dimensions
Light Distribution Pattern
Clear Lens
Diffused Lens
36
www.dialight.com
DuroSite Industrial Application| Linear
36 www.dialight.com
DuroSite® LED End-to-End Linearfor Industrial applications
Dimensions
Light Distribution Pattern
Clear Lens Diffused Lens
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,500 60 125 20’
6,750 60 113
4,000 32 125
3,500 32 109 10’
Ratings and Certifications
• UL 1598/A • IP66/67
• CSA 22.2 No. 250.0 • NEMA 4X
• 5yr full performance warranty • L70 rated for >125,000 hours
Mechanical information
Fixture weight:4’ linear: 18 lbs (8.16 kg)
2’ linear: 13 lbs (5.90 kg)
Shipping weight:
4’ linear: 20 lbs (9.07 kg)
2’ linear: 15 lbs (6.80 kg)
Mounting: (4) 3/4” NPT openings
Optional ceiling, flush or swivel mounting bracket
ComparisonWarranty L70 T-Rating
Dialight Linear 5yr >125,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Fluorescent 1 24,000 T3
Specifications
Voltage options: 120 - 277V AC Housing: Extruded 6063 aluminum
Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Polycarbonate
Power factor: >0.9 CRI: 80
THD: <20% CCT: 5000K (cool white)
Surge protection: 6 kV line to line, 6 kV line to ground 4000K (neutral white)
*All features not available on every model. Please refer to product part number pages for model specifics.
2' Models 4' Models
DuroSite Industrial Application I Linear
DuroSite® LED End-to-End Linear Ordering Information and Mounting Accessories
Fixture Lumen
Watt LPW Voltage CCT Lens Optical Pattern
7,500 60 125
6,750 60 113
4,000 32 125
3,500 32 109
120 - 277V AC 5000K (cool white) Clear polycarbonate Circular
Circular
Circular
Circular
120 - 277V AC 5000K (cool white) Diffused polycarbonate
120 - 277V AC 5000K (cool white) Clear polycarbonate
120 - 277V AC 5000K (cool white) Diffused polycarbonate
■ 4' 80
4' 80
2' 80
2' 80
LBU2MB3FNNNNGN
LBU6MB3FNNNNGN
LAU2MB3BNNNNGN
LAU6MB3BNNNNGN
Part Number Length
All lumen values are typical (tolerance +1- 10%) Part numbers listed in the above table are cool white. For neutral white models replace the 6th character with N. Ex. LBU2MB3FNNNNGN becomes LBU2MN3FNNNNGN.
Swivel Mount
EEX-S6 • 316 Stainless steel swivel mounting
bracket • Can be angled at 0°, 30°, 45°, 60°,
and 90°
Ceiling Mount
Flush Mount
www.dialight.com 37
EEX-C6 • 316 Stainless steel fixed ceiling mount
EEX-F6 • 316 Stainless steel flush mount
DuroSite Industrial Application| Linear
www.dialight.com 37
DuroSite® LED End-to-End LinearOrdering Information and Mounting Accessories
All lumen values are typical (tolerance +/- 10%)
Part numbers listed in the above table are cool white. For neutral white models replace the 6th character with N. Ex. LBU2MB3FNNNNGN becomes LBU2MN3FNNNNGN.
Part Number Length CRIFixture Lumen
Watt LPW Voltage CCT LensOptical Pattern
LBU2MB3FNNNNGN 4' 80 7,500 60 125 120 - 277V AC 5000K (cool white) Clear polycarbonate Circular
LBU6MB3FNNNNGN 4' 80 6,750 60 113 120 - 277V AC 5000K (cool white) Diffused polycarbonate Circular
LAU2MB3BNNNNGN 2' 80 4,000 32 125 120 - 277V AC 5000K (cool white) Clear polycarbonate Circular
LAU6MB3BNNNNGN 2' 80 3,500 32 109 120 - 277V AC 5000K (cool white) Diffused polycarbonate Circular
EEX-S6• 316 Stainless steel swivel mounting
bracket• Can be angled at 0°, 30°, 45°, 60°,
and 90°
EEX-C6• 316 Stainless steel fixed ceiling mount
Ceiling Mount
Flush Mount
EEX-F6• 316 Stainless steel flush mount
Swivel Mount
Specifications
Voltage options: Operating temp: Power factor: THD: Surge protection:
100 - 277V AC -40°F to +149°F (-40°C to +65°C)
>0.9 <20% 4 kV line to line, 4 kV line to ground
Copper free aluminum Polycarbonate 75 / 80 5000K (cool white) 4000K (neutral white)
Housing: Lens: CRI: CCT:
DuroSite
DuroSite® LED Linear - Low Profile for Industrial applications
Industrial Application I Linear
Ratings and Certifications
• UL 1598/A
• CSA 22 #250 • UL 8750
• 5yr full performance warranty • IP66/67
• L70 rated for >100,000 hours • NEMA 4X
"AI features not available on every model. Rease refer to product part number pages for model specifics.
Mechanical information
Fixture weight: 4' linear: 10 lbs (4.50 kg) 2' linear: 7 lbs (3.13 kg)
Shipping weight:
4' linear: 11 lbs (4.90 kg
2' linear: 8 lbs (3.64 kg)
Mounting: (4) 3/4" NPT openings
Optional swivel bracket - LPXW4
Optional low profile bracket - LPXW4LP
Dialight Linear Metal Halide High Pressure Sodium Fluorescent
Comparison Warranty
5yr 1 1 1
L70
>150,000 6,000 20,000 24,000
Lumens
7,250 6,900 3,500 3,300
Dimensions
Wattage
66 66 33 33
Im/W
110
105 106 100
Mounting Heights
20'
10'
4711 1121+1.4]
1. 4' Friii
3.46- MA I 177,U1 t60g.2.]
-.j*L [124 651
Dimension are in Inches [mm]
Light Distribution Pattern
Circular Pattern
38 www.dialight.com
DuroSite Industrial Application| Linear
38 www.dialight.com
Dimensions
Light Distribution Pattern
Circular Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,250 66 110 20’
6,900 66 105
3,500 33 106
3,300 33 100 10’
Ratings and Certifications
• UL 1598/A • CSA 22 #250
• UL 8750 • 5yr full performance warranty
• IP66/67 • L70 rated for >100,000 hours
• NEMA 4X
Mechanical information
Fixture weight:4’ linear: 10 lbs (4.50 kg)
2’ linear: 7 lbs (3.13 kg)
Shipping weight:
4’ linear: 11 lbs (4.90 kg
2’ linear: 8 lbs (3.64 kg)
Mounting: (4) 3/4” NPT openings
Optional swivel bracket - LPXW4
Optional low profile bracket - LPXW4LP
Comparison
Warranty L70
Dialight Linear 5yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Fluorescent 1 24,000
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Polycarbonate
Power factor: >0.9 CRI: 75 / 80
THD: <20% CCT: 5000K (cool white)
Surge protection: 4 kV line to line, 4 kV line to ground 4000K (neutral white)
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED Linear - Low Profilefor Industrial applications
DuroSite
Industrial Application I Linear
DuroSite® LED Linear - Low Profile Ordering Information and Mounting Accessories
Watt LPW Part Number Length CRI Fixture Lumen
Warranty Voltage CCT Lens Light
Distribution Pattern
LPM3C4M2P 4' 75 7,250 66 110 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LPM3C4H2W 4' 75 6,700 66 102 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LPM3B4M2P 4' 80 6,500 66 98 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LPM3B4H2W 4' 80 6,000 66 91 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LPM3C4D2P 2' 75 3,600 33 109 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LPM3C4B2W 2' 75 3,300 33 100 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LPM3B4D2P 2' 80 3,200 33 97 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LPM3B4B2W 2' 80 2,900 33 88 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
LPXW4 • Mounting bracket
• Can be angled at 0°, 30°, 45°, 60° & 90°
LPXW4LP • Low profile mounting
bracket • Can be angled at 0° and
15°
LTXENDCAPKIT • Chain mount and
secondary retention bracket
LTXSAFEKIT • Safety Cable Kit for
secondary retention
www.dialight.com 39
DuroSite Industrial Application| Linear
www.dialight.com 39
Part Number Length CRIFixture Lumen
Watt LPW Warranty Voltage CCT LensLight
Distribution Pattern
LPM3C4M2P 4’ 75 7,250 66 110 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LPM3C4H2W 4’ 75 6,700 66 102 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LPM3B4M2P 4’ 80 6,500 66 98 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LPM3B4H2W 4’ 80 6,000 66 91 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LPM3C4D2P 2’ 75 3,600 33 109 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LPM3C4B2W 2’ 75 3,300 33 100 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LPM3B4D2P 2’ 80 3,200 33 97 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LPM3B4B2W 2’ 80 2,900 33 88 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
DuroSite® LED Linear - Low ProfileOrdering Information and Mounting Accessories
LTXSAFEKIT• Safety Cable Kit for
secondary retention
LPXW4LP• Low profile mounting
bracket• Can be angled at 0° and
15°
LTXENDCAPKIT• Chain mount and
secondary retention bracket
LPXW4• Mounting bracket• Can be angled at 0°, 30°,
45°, 60° & 90°
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
DuroSite
Industrial Application I Linear
DuroSite® LED Linear - Top Conduit for Industrial application:
Mechanical information
Fixture weight: 4' linear: 11 lbs (4.99 kg) 2' linear: 10 lbs (4.53 kg)
Shipping weight:
4' linear: 13 lbs (5.90 kg)
2' linear: 12 lbs (5.44 kg)
Mounting: (3) 3/4" NPT openings Optional swivel bracket - LTXW4 Optional low profile bracket - LTXW4LP
Comparison
Warranty Dialight Linear
5yr Metal Halide
1
High Pressure Sodium
1
Fluorescent
1
Ratings and Certifications
• UL 1598/A
• CSA 22 #250 • UL 8750
• 5yr full performance warranty • IP66
• L70 rated for >100,000 hours • NEMA 4X
"All features not available on every model. Please refer to product part number pages for model specifics.
Specifications
Voltage options: Operating temp: Power factor: THD: Surge protection:
100 - 277V AC -40°F to +149°F (-40°C to +65°C)
>0.9 <20% 4 kV line to line, 4 kV line to ground
Housing: Lens: CRI: CCT:
Copper free aluminum Polycarbonate 75 / 80 5000K (cool white) 4000K (neutral white)
Lumens Wattage Im/W Mounting Heights
L70 7,250 66 110 20' >150,000 6,900 66 105
6,000 3,500 33 106 20,000 3,300 33 100 10' 24,000
Dimensions
0 • I;
[11
AIL
7,d7 114.45)
126.5]
42.96 La, r 213,21
• [2111)
Dimension are in Inches [mm]
Light Distribution Pattern
Circular Pattern
40 www.dialight.com
DuroSite Industrial Application| Linear
40 www.dialight.com
Dimensions
Light Distribution Pattern
Circular Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,250 66 110 20’
6,900 66 105
3,500 33 106
3,300 33 100 10’
Ratings and Certifications
• UL 1598/A • CSA 22 #250
• UL 8750 • 5yr full performance warranty
• IP66 • L70 rated for >100,000 hours
• NEMA 4X
Mechanical information
Fixture weight:4’ linear: 11 lbs (4.99 kg)
2’ linear: 10 lbs (4.53 kg)
Shipping weight:
4’ linear: 13 lbs (5.90 kg)
2’ linear: 12 lbs (5.44 kg)
Mounting: (3) 3/4” NPT openings
Optional swivel bracket - LTXW4Optional low profile bracket - LTXW4LP
Comparison
Warranty L70
Dialight Linear 5yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Fluorescent 1 24,000
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Polycarbonate
Power factor: >0.9 CRI: 75 / 80
THD: <20% CCT: 5000K (cool white)
Surge protection: 4 kV line to line, 4 kV line to ground 4000K (neutral white)
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED Linear - Top Conduitfor Industrial applications
DuroSite
Industrial Application I Linear
DuroSite® LED Linear - Top Conduit Ordering Information and Mounting Accessories
Part Number Length CRI Fixture Lumen
Watt LPW Warranty Voltage CCT Lens Light
Distribution Pattern
LTM3C4M2P 4' 75 7,250 66 110 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LTM3C4H2W 4' 75 6,700 66 102 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LTM3B4M2P 4' 80 6,500 66 98 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LTM3B4H2W 4' 80 6,000 66 91 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LTM3C4D2P 2' 75 3,600 33 109 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LTM3C4B2W 2' 75 3,300 33 100 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LTM3B4D2P 2' 80 3,200 33 97 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LTM3B4B2W 2' 80 2,900 33 88 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%). Part numbers listed in the table above are cool white. For neutral white model, replace the 5th character with N Ex. LTM3C4D2P becomes LTM3N4D2P
LTXW4 • Mounting bracket
• Can be angled at 0°, 30°, 45°, 60° & 90°
LTXW4LP • Low profile mounting
bracket
• Can be angled at 0° and 15°
LTXENDCAPKIT • Chain mount and
secondary retention bracket
LTXSAFEKIT • Safety Cable Kit for
secondary retention
LTXLSXW4 • Retrofit bracket adapter
used to connect LTM model fixtures to an existing LSXW4 bracket
www.dialight.com 41
DuroSite Industrial Application| Linear
www.dialight.com 41
Part numbers listed in the table above are cool white. For neutral white model, replace the 5th character with N. Ex. LTM3C4D2P becomes LTM3N4D2P
DuroSite® LED Linear - Top ConduitOrdering Information and Mounting Accessories
LTXSAFEKIT• Safety Cable Kit for
secondary retention
LTXW4LP• Low profile mounting
bracket• Can be angled at 0° and
15°
LTXENDCAPKIT• Chain mount and
secondary retention bracket
LTXW4• Mounting bracket• Can be angled at 0°, 30°,
45°, 60° & 90°
Part Number Length CRIFixture Lumen
Watt LPW Warranty Voltage CCT LensLight
Distribution Pattern
LTM3C4M2P 4’ 75 7,250 66 110 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LTM3C4H2W 4’ 75 6,700 66 102 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LTM3B4M2P 4’ 80 6,500 66 98 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LTM3B4H2W 4’ 80 6,000 66 91 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LTM3C4D2P 2’ 75 3,600 33 109 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LTM3C4B2W 2’ 75 3,300 33 100 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LTM3B4D2P 2’ 80 3,200 33 97 5yr 100 - 277 V AC 5000K (cool white) Clear Polycarbonate Circular
LTM3B4B2W 2’ 80 2,900 33 88 5yr 100 - 277 V AC 5000K (cool white) Diffused polycarbonate Circular
LTXLSXW4• Retrofit bracket adapter
used to connect LTM model fixtures to an existing LSXW4 bracket
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Industrial Application I Linear DuroSite
DuroSite® LED Linear - Battery Backup for Industrial applications
• UL 1598/A
• UL 924
• IP66
• NEMA 4X "Al features not available on every model. specifics.
Ratings and Certifications
• CSA 22.2 #250
• 3yr full performance warranty
• L70 rated for >125,000 hours
Please refer to product part number pages for model
Im/W Mounting Heights
20' and under 85
Lumens
7,000
Wattage
85
Light Distribution Pattern Dimensions
17.01 (1214,4]
18..2 i4703I 6.66
[69.I]
Dimension are in Inches [mm]
6.1.0 - [162,6]
42 www.dialight.com
Specifications
Voltage options: 120 - 277V AC Housing: Copper free aluminum
Operating temp: -20°F to +149°F (-20°C to +65°C) Lens: Polycarbonate
Power factor: >0.9 CRI: 75
THD: <20% CCT: 5000K (cool white)
Surge protection: 1 kV line to line, 2 kV line to ground Battery Life: 4 years
Battery: 3.6V 10Ah Nimh Battery Duration: >3 hours
Comparison
Warranty L70
3yr >125,000
1 6,000
1 20,000
1 24,000
Dialight Linear
Metal Halide
High Pressure Sodium
Fluorescent
This fixture is offered in sustained and maintained configurations. Sustained has a single AC input and battery backup mode is entered upon any loss of power. Fixture cannot be turned off without entering battery backup mode.
Maintained has two AC inputs. The fixture can be turned on and off via AC-1 and Fixture only enters battery backup mode when AC-2 is lost or low.
85 85 5yr
5yr 85 85
Type Part Number Length
LSM3C4MEP 4' Sustained 75 7,000
LSM3C4MNP 4' Maintained 75 7,000
Light Voltage CCT Lens Distribution
Pattern
100 - 277 V AC 5000K (cool white) Polycarbonate Circular
100 - 277 V AC 5000K (cool white) Polycarbonate Circular
LPW Warranty CRI Fixture Lumen
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
LSXW4
• Mounting bracket
• Can be angled at 0°, 30°, 45°, 60° & 90°
LSXENDCAPKIT
• Chain mount brackets HZXSAFEKIT
• Safety Cable Kit
Circular Pattern
mechanical information
Fixture weight: 18 lbs (8.16 kg)
Shipping weight: 21 lbs (9.53 kg)
Mounting: (1) Threaded 3/4" NPT Side (2) Threaded 3/4" NPT Ends
DuroSite Industrial Application| Linear
42 www.dialight.com
Dimensions Light Distribution Pattern
Circular PatternDimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,000 85 85 20’ and under
Ratings and Certifications
• UL 1598/A • CSA 22.2 #250
• UL 924 • 3yr full performance warranty
• IP66 • L70 rated for >125,000 hours
• NEMA 4X
Mechanical information
Fixture weight: 18 lbs (8.16 kg)
Shipping weight: 21 lbs (9.53 kg)
Mounting: (1) Threaded 3/4” NPT Side(2) Threaded 3/4” NPT Ends
Comparison
Warranty L70
Dialight Linear 3yr >125,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Fluorescent 1 24,000
Specifications
Voltage options: 120 - 277V AC Housing: Copper free aluminum
Operating temp: -20°F to +149°F (-20°C to +65°C) Lens: Polycarbonate
Power factor: >0.9 CRI: 75
THD: <20% CCT: 5000K (cool white)
Surge protection: 1 kV line to line, 2 kV line to ground Battery Life: 4 years
Battery: 3.6V 10Ah Nimh Battery Duration: >3 hours
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED Linear - Battery Backupfor Industrial applications
Part Number Length Type CRIFixture Lumen
Watt LPW Warranty Voltage CCT LensLight
Distribution Pattern
LSM3C4MEP 4’ Sustained 75 7,000 85 85 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate Circular
LSM3C4MNP 4’ Maintained 75 7,000 85 85 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate Circular
LSXENDCAPKIT• Chain mount brackets
HZXSAFEKIT• Safety Cable Kit
LSXW4• Mounting bracket• Can be angled at 0°, 30°,
45°, 60° & 90°
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
This fixture is offered in sustained and maintained configurations. Sustained has a single AC input and battery backup mode is entered upon any loss of power. Fixture cannot be turned off without entering battery backup mode.
Maintained has two AC inputs. The fixture can be turned on and off via AC-1 and Fixture only enters battery backup mode when AC-2 is lost or low.
Mechanical information
Fixture weight:
Standard: 12 lbs (5.5 kg)
Wall mount: 18 lbs (8.2 kg)
45° Wall mount: 17 lbs (7.8 kg)
45° Stanchion mount: 18 lbs (8.1 kg)
Shipping weight:
Standard:
13 lbs (7.5 kg)
Wall mount:
20 lbs (10.1 kg)
45° Wall mount:
19 lbs (9.8 kg)
45° Stanchion mount:
20 lbs (10.1 kg)
Mounting:
(1) Threaded 3/4" NPT rear
Cabling: 10' (3.5m) STOOW Power Cord
(Except when ordered with mounting bracket)
Comparison
Warranty
5yr
1
1
L70
>150,000
6,000
20,000
Dialight Area Light
Metal Halide
High Pressure Sodium
.6a au FE.)
•71) 1 1I
• ill 15 C rtArs2
10,63 127C.61 O c;
1-11.67
•
L
V29.6.•39 '
I I 00 ,279.5
. :
Wall Mount Models
1 00 12 70.4.1 13.190.1a..11
Ea 5a t2
/2,1615.151 liveaclo 104 2 PI:rf
450 Stanchion Mount Models 45° Wall Mount Models
Standard Models
DuroSite
Industrial Application I Area Light
DuroSite® LED Area Light for Industrial applications
Standard Models
Wall Mount Models
45° Stanchion Mount Models
45° Wall Mount Models
Ratings and Certifications
• UL 1598/A
• ABS Design Assessed: # 12-HS942957-PDA
• CSA 22.2
• DLC listed
• IP66/67
• 5yr full performance warranty
• NEMA 4X
• L70 rated for >150,000 hours "Al features not available on every model. Please refer to product part number pages for model specifics.
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
347 - 480V AC Lens: Polycarbonate
24 - 48V DC Tempered glass
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% 4000K (neutral white)
Surge protection:
100 — 277V AC 1 kV line to line, 2 kV line to ground
347 — 480V AC 6 kV line to line, 6 kV line to ground
Lumens Watt Im/W
Mounting Heights
7,250 69 105 20' 6,500 69 94 5,600 58 97 4,700 47 100
3,700 38 97 2,200 21 105 10'
Dimensions
Light Distribution Patterns
360° Light Distribution Pattern
180° Light Distribution Pattern
Wide Throw
www.dialight.com 43
DuroSite Industrial Application| Area Light
www.dialight.com 43
Dimensions
Lumens Watt lm/W Mounting Heights7,250 69 105 20’6,500 69 945,600 58 974,700 47 1003,700 38 972,200 21 105 10’
Ratings and Certifications
• UL 1598/A • ABS Design Assessed: # 12-HS942957-PDA
• CSA 22.2 • DLC listed
• IP66/67 • 5yr full performance warranty
• NEMA 4X • L70 rated for >150,000 hours
Mechanical information
Fixture weight:Standard: 12 lbs (5.5 kg)
Wall mount: 18 lbs (8.2 kg)
45o Wall mount: 17 lbs (7.8 kg)
45o Stanchion mount: 18 lbs (8.1 kg)
Shipping weight:
Standard: 13 lbs (7.5 kg)
Wall mount: 20 lbs (10.1 kg)
45o Wall mount: 19 lbs (9.8 kg)
45o Stanchion mount: 20 lbs (10.1 kg)
Mounting: (1) Threaded 3/4” NPT rear
Cabling:10’ (3.5m) STOOW Power Cord
(Except when ordered with mounting bracket)
Comparison
Warranty L70
Dialight Area Light 5yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
347 - 480V AC Lens: Polycarbonate
24 - 48V DC Tempered glass
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% 4000K (neutral white)
Surge protection:100 – 277V AC 1 kV line to line, 2 kV line to ground
347 – 480V AC 6 kV line to line, 6 kV line to ground
Standard Models Wall Mount Models
45o Stanchion Mount Models 45o Wall Mount Models
Standard Models Wall Mount Models 45o Stanchion Mount Models 45o Wall Mount Models
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED Area Lightfor Industrial applications
Light Distribution Patterns
360° Light Distribution Pattern
180° Light Distribution Pattern
Wide Throw
Part Number
5'1
S1WFC2N standard model
S1WEC2N standard model
S1W9C2N standard model
S1W8C2N standard model
S1W5C2N standard model
S1W4C2N standard model
S1WWC2N standard model
S1W3C2N standard model
S1W2C2N standard model
S1W1C2N standard model
S1WOC2N standard model
Er
S1W9C9N standard model
S1W8C9N standard model
S1W5C9N standard model
S1W4C9N standard model
S1WWC9N standard model
S1W3C9N standard model
S1W2C9N standard model
S1WFC8N
standard model
S1WEC8N
standard model
DuroSite
Industrial Application I Area Light
DuroSite® LED Area Light Ordering Information and Mounting Accessories
Fixture Lumen Watt LPW Warranty Voltage Light
Distribution Pattern
Standard Models - 100 - 277V AC
7,000 69 101 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 360
7,000 69 101 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 180
6,000 58 103 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 360
6,000 58 103 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 180
5,000 47 106 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 360
5,000 47 106 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 180
4,100 54 76 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate Wide Throw
4,000 38 105 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 360
4,000 38 105 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 180
2,200 21 105 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 360
2,200 21 105 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 180
Standard Models - 347 - 480V AC
6,000 58 103 5yr 347-480V AC 5000K (cool white) Polycarbonate 360
6,000 58 103 5yr 347-480V AC 5000K (cool white) Polycarbonate 180
5,000 47 110 5yr 347-480V AC 5000K (cool white) Polycarbonate 360
5,000 47 110 5yr 347-480V AC 5000K (cool white) Polycarbonate 180
4,100 54 76 5yr 347-480V AC 5000K (cool white) Polycarbonate Wide Throw
4,000 38 105 5yr 347-480V AC 5000K (cool white) Polycarbonate 360
4,000 38 105 5yr 347-480V AC 5000K (cool white) Polycarbonate 180
Standard Models - 24 - 48V DC
7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 360
7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 180 'men values are typical (toleranc
180° Light Distribution Pattern models are optimized for a 45° mounting angle Part numbers listed in the above table are 5000K (cool white) . For 4000K (neutral white) model replace the 5th character with N Ex: S1W2C2N becomes S1W2N2N Part numbers listed in the tables above come with a polycarbonate lens. For models needing a glass lens, replace the 7th character with a 0 Ex: S1W2C2N becomes S1W2C20 Part numbers listed in the above table are 100-277V AC. For 347-480V AC model replace the 6th character with 2 Ex: S1W2C2N becomes S1W2C2N
44
www.dialight.com
DuroSite Industrial Application| Area Light
44 www.dialight.com
DuroSite® LED Area LightOrdering Information and Mounting Accessories
Part Number Type Fixture Lumen Watt LPW Warranty Voltage CCT LensLight
Distribution Pattern
Standard Models - 100 - 277V AC
STWFC2N standard model 7,000 69 101 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STWEC2N standard model 7,000 69 101 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STW9C2N standard model 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW8C2N standard model 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STW5C2N standard model 5,000 47 106 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW4C2N standard model 5,000 47 106 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STWWC2N standard model 4,100 54 76 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate Wide Throw
STW3C2N standard model 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW2C2N standard model 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STW1C2N standard model 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW0C2N standard model 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
Standard Models - 347 - 480V AC
STW9C9N standard model 6,000 58 103 5yr 347-480V AC 5000K (cool white) Polycarbonate 360
STW8C9N standard model 6,000 58 103 5yr 347-480V AC 5000K (cool white) Polycarbonate 180
STW5C9N standard model 5,000 47 110 5yr 347-480V AC 5000K (cool white) Polycarbonate 360
STW4C9N standard model 5,000 47 110 5yr 347-480V AC 5000K (cool white) Polycarbonate 180
STWWC9N standard model 4,100 54 76 5yr 347-480V AC 5000K (cool white) Polycarbonate Wide Throw
STW3C9N standard model 4,000 38 105 5yr 347-480V AC 5000K (cool white) Polycarbonate 360
STW2C9N standard model 4,000 38 105 5yr 347-480V AC 5000K (cool white) Polycarbonate 180
Standard Models - 24 - 48V DC
STWFC8N standard model 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 360
STWEC8N standard model 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 180
1180° Light Distribution Pattern models are optimized for a 45° mounting angle2Part numbers listed in the above table are 5000K (cool white) . For 4000K (neutral white) model replace the 5th character with N Ex: STW2C2N becomes STW2N2N3Part numbers listed in the tables above come with a polycarbonate lens. For models needing a glass lens, replace the 7th character with a G Ex: STW2C2N becomes STW2C2G4Part numbers listed in the above table are 100-277V AC. For 347-480V AC model replace the 6th character with 9 Ex: STW2C2N becomes STW2C9N
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
DuroSite
Industrial Application I Area Light
DuroSite® LED Area Light Ordering Information and Mounting Accessories
Part Number Type Fixture Lumen Watt LPW Warranty Voltage CCT Light
Distribution Pattern
45° Wall Mount - 100 - 277V AC
S1VVFC2NW45 450 Wall Mount 7,000 68 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
S1VVEC2NW45 45° Wall Mount 7,000 68 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
S1W9C2NW45 450 Wall Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
S1W8C2NW45 45° Wall Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
S1W5C2NW45 450 Wall Mount 5,000 47 106 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
S1W4C2NW45 45° Wall Mount 4,700 47 100 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
S1VVVVC2NW45 450 Wall Mount 4,100 60 68 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate Wide Throw
S1W3C2NW45 45° Wall Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
S1W2C2NW45 450 Wall Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
s-rwi C2NW45 45° Wall Mount 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
S1WOC2NW45 450 Wall Mount 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
45° Wall Mount - 24 - 48V DC
S1VVFC8NW45 450 Wall Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 360
S1VVEC8NW45 45° Wall Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 180
45° Stanchion Mount Bracket - 100 - 277V AC
S1VVFC2NS45 45° Stanchion Mount 7,000 68 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
S1VVEC2NS45 45° Stanchion Mount 7,000 68 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
S1W9C2NS45 45° Stanchion Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
S1W8C2NS45 45° Stanchion Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
S1W5C2NS45 45° Stanchion Mount 5,000 47 106 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
S1W4C2NS45 45° Stanchion Mount 4,700 47 100 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 180
S1VVVVC2NS45 45° Stanchion Mount 4,100 60 68 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate VVide Throw
S1W3C2NS45 45° Stanchion Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
S1W2C2NS45 45° Stanchion Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
s-rwi C2NS45 45° Stanchion Mount 2,200 21 105 5yr 100 - 277VAC 5000K (cool white) Polycarbonate 360
S1WOC2NS45 45° Stanchion Mount 2,200 21 105 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 180
45° Stanchion Mount Bracket - 24 - 48V DC
S1VVFC8NS45 45° Stanchion Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 360
S1VVEC8NS45 45° Stanchion Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 180
Wall Mount - 100 - 277V AC
SIVVFC2NWO1 Wall Mount 7,000 68 103 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 360
SIW9C2NWO1 Wall Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
SIW5C2NWO1 Wall Mount 5,000 47 106 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate 360
SIVVVVC2NVV01 Wall Mount 4,100 60 68 5yr 100 - 277 VAC 5000K (cool white) Polycarbonate VVide Throw
SIW3C2NWO1 Wall Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
s-rwi C2NWO1 Wall Mount 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
Wall Mount - 24 - 48V DC
SIVVFC8NWO1 Wall Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 360
All values iypic, less otherwise stated, L, typical (tolerance +/- 10%).
'Part numbers listed in the above table are 5000K (cool while) . For 4000K (neutral while) model replace the 5th character with N Ex: S1W2Q2N becomes S1W2N2N Part numbers listed in the tables above come with a polycarbonale lens. For models needing a glass lens, replace the 7th character with a 0 Ex: S1W2C2N becomes S1W2C2O Part numbers listed in the above table are 100-277V AC. For 347-480V AC model replace the 6th character with 9 Ex: STW2C2N becomes S1W2C9N
www.dialight.com
45
DuroSite Industrial Application| Area Light
www.dialight.com 45
DuroSite® LED Area LightOrdering Information and Mounting Accessories
2Part numbers listed in the above table are 5000K (cool white) . For 4000K (neutral white) model replace the 5th character with N Ex: STW2C2N becomes STW2N2N3Part numbers listed in the tables above come with a polycarbonate lens. For models needing a glass lens, replace the 7th character with a G Ex: STW2C2N becomes STW2C2G4Part numbers listed in the above table are 100-277V AC. For 347-480V AC model replace the 6th character with 9 Ex: STW2C2N becomes STW2C9N
Part Number Type Fixture Lumen Watt LPW Warranty Voltage CCT LensLight
Distribution Pattern
45o Wall Mount - 100 - 277V AC
STWFC2NW45 45o Wall Mount 7,000 68 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STWEC2NW45 45o Wall Mount 7,000 68 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STW9C2NW45 45o Wall Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW8C2NW45 45o Wall Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STW5C2NW45 45o Wall Mount 5,000 47 106 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW4C2NW45 45o Wall Mount 4,700 47 100 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STWWC2NW45 45o Wall Mount 4,100 60 68 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate Wide Throw
STW3C2NW45 45o Wall Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW2C2NW45 45o Wall Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STW1C2NW45 45o Wall Mount 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW0C2NW45 45o Wall Mount 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
45o Wall Mount - 24 - 48V DC
STWFC8NW45 45o Wall Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 360
STWEC8NW45 45o Wall Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 180
45o Stanchion Mount Bracket - 100 - 277V AC
STWFC2NS45 45o Stanchion Mount 7,000 68 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STWEC2NS45 45o Stanchion Mount 7,000 68 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STW9C2NS45 45o Stanchion Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW8C2NS45 45o Stanchion Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STW5C2NS45 45o Stanchion Mount 5,000 47 106 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW4C2NS45 45o Stanchion Mount 4,700 47 100 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STWWC2NS45 45o Stanchion Mount 4,100 60 68 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate Wide Throw
STW3C2NS45 45o Stanchion Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW2C2NS45 45o Stanchion Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
STW1C2NS45 45o Stanchion Mount 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW0C2NS45 45o Stanchion Mount 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 180
45o Stanchion Mount Bracket - 24 - 48V DC
STWFC8NS45 45o Stanchion Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 360
STWEC8NS45 45o Stanchion Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 180
Wall Mount - 100 - 277V AC
STWFC2NW01 Wall Mount 7,000 68 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW9C2NW01 Wall Mount 6,000 58 103 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW5C2NW01 Wall Mount 5,000 47 106 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STWWC2NW01 Wall Mount 4,100 60 68 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate Wide Throw
STW3C2NW01 Wall Mount 4,000 38 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
STW1C2NW01 Wall Mount 2,200 21 105 5yr 100 - 277 V AC 5000K (cool white) Polycarbonate 360
Wall Mount - 24 - 48V DC
STWFC8NW01 Wall Mount 7,000 71 99 5yr 24 - 48V DC 5000K (cool white) Polycarbonate 360
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
DuroSite
Industrial Application I Area Light
DuroSite® LED Area Light Ordering Information and Mounting Accessories
HZXSTAN100S • 1.00" (1.315" Pole OD) slip-fit stanchion mount junction box
HZXSTAN125S • 1.25" (1.660" Pole OD) slip-fit stanchion mount junction box
HZXSTAN150S • 1.50" (1.900" Pole OD) slip-fit stanchion mount junction box
HZXSTAN200S • 2.00" (2.375" Pole OD) slip-fit stanchion mount junction box
HZXSTAN100T • 1.00" (1.315" Pole OD) NPT threaded stanchion mount
junction box
HZXSTAN125T • 1.25" (1.660" Pole
junction box
HZXSTAN150T • 1.50" (1.900" Pole
junction box
HZXSTAN200T • 2.00" (2.375" Pole
junction box
OD) NPT threaded stanchion mount
OD) NPT threaded stanchion mount
OD) NPT threaded stanchion mount
HZXW3
• Stainless steel bracket
HZXW7 • Aluminum bracket
fArftle! lend
HZXW4 • Stainless steel bracket with pipe clamp
HZXW8 • Aluminum bracket with pipe clamp
HZXSAFEKIT • Safety cable kit
HZXSAFETABS
• Safety tabs
HZXJB075
• 0.75" Ceiling / wall / pole mount junction box
HZXJB100 • 1.00" Ceiling / wall / pole mount junction box
HZXJB125 • 1.25" Ceiling / wall / pole mount junction box
HZXJB150 • 1.50" Ceiling / wall / pole mount junction box
HZXJB075PC1 • 0.75" Junction box with Photocell
HZXJB100PC1 • 1.00" Junction box with Photocell
HZXJB125PC1 • 1.25" Junction box with Photocell
HZXJB150PC1 • 1.50" Junction box with Photocell
STXLENSPD • Polycarbonate replacement lens
46 www.dialight.com
DuroSite Industrial Application| Area Light
46 www.dialight.com
HZXW3• Stainless steel bracket
HZXW7• Aluminum bracket
HZXSAFETABS• Safety tabs
HZXSTAN100S• 1.00” (1.315” Pole OD) slip-fit stanchion mount junction box
HZXSTAN125S• 1.25” (1.660” Pole OD) slip-fit stanchion mount junction box
HZXSTAN150S• 1.50” (1.900” Pole OD) slip-fit stanchion mount junction box
HZXSTAN200S• 2.00” (2.375” Pole OD) slip-fit stanchion mount junction box
HZXSTAN100T• 1.00” (1.315” Pole OD) NPT threaded stanchion mount
junction box
HZXSTAN125T• 1.25” (1.660” Pole OD) NPT threaded stanchion mount
junction box
HZXSTAN150T• 1.50” (1.900” Pole OD) NPT threaded stanchion mount
junction box
HZXSTAN200T• 2.00” (2.375” Pole OD) NPT threaded stanchion mount
junction box
HZXW4• Stainless steel bracket with pipe clamp
HZXW8• Aluminum bracket with pipe clamp
HZXJB075• 0.75” Ceiling / wall / pole mount junction box
HZXJB100• 1.00” Ceiling / wall / pole mount junction box
HZXJB125• 1.25” Ceiling / wall / pole mount junction box
HZXJB150• 1.50” Ceiling / wall / pole mount junction box
HZXSAFEKIT • Safety cable kit
HZXJB075PC1• 0.75” Junction box with Photocell
HZXJB100PC1• 1.00” Junction box with Photocell
HZXJB125PC1• 1.25” Junction box with Photocell
HZXJB150PC1• 1.50” Junction box with Photocell
DuroSite® LED Area LightOrdering Information and Mounting Accessories
STXLENSPD• Polycarbonate replacement lens
Wall
VMB2B & VMB-2
VMB3B & VMB-3
Stanchion
VMD4B
VMDSB
VMSSB
DuroSite
Industrial Application I Area Light
DuroSite® LED Area Light Retrofit Options Overview
S1VV)000( models can be ordered with factory installed retrofit adapter by adding K, A C, G, or M to the end of the part number. For example, STW8C2N becomes STW8C2NC. Please consult factory when ordering. Retrofit options are not suitable for use in Class I Div.1 environments
C = Eaton's Crouse-Hinds - Champ® A = Appleton® Mercmaster Ill K = Ki!lark° Certilite® & Certilite® V G = GE Lighting Solutions - Rltr-GardTM
Eaton's Crouse-Hinds - Champ® - HZXTHCH
Pendant
Ceiling
Wall
Stanchion
Quad Mount
APM2
CM2
TWM2
JM5
QM25
APM3
CM3
TWM3
PM5
HPM2
Appleton® Mercmaster Ill - HZXTHAP
Pendant Ceiling Wall
Stanchion
KPA-75
KPA-100
KPAF-75
KPAF-100
KPCH-75
KPCH - 100
KPC-75
KPC-100
KPWB-75
KPWB-100
KPS-125
KPS-150
KPST-125
KPST-150
KiIlark® Certilite® & Certilite® V - HZXTHKL
VMA2B & VMA-2
VMA3B & VMA-3
VMC2B & VMC-2
VMC3B & VMC-3
VMF2B
VMF3B
VMX2B & VMX-2
VMX3B & VMX-3
VMX6B
VMX7B
VMXBB
VMX9B
Pendant
Ceiling
GE Lighting Solutions - Filtr-GardTM - HZXTHGE
Pendant
Ceiling
Wall
Stanchion
Quad Mount
3P
3F
3C
3W
5S
4P
4F
4C
4W
6S
5J
6J
www.dialight.com 47
DuroSite Industrial Application| Area Light
www.dialight.com 47
DuroSite® LED Area Light Retrofit Options Overview
Appleton® Mercmaster III - HZXTHAP
Pendant Ceiling Wall Stanchion
KPA-75 KPC-75 KPWB-75 KPS-125
KPA-100 KPC-100 KPWB-100 KPS-150
KPAF-75 KPST-125
KPAF-100 KPST-150
KPCH-75
KPCH-100
Eaton’s Crouse-Hinds – Champ® - HZXTHCH
Pendant Ceiling Wall Stanchion Quad Mount
APM2 CM2 TWM2 JM5 QM25
APM3 CM3 TWM3 PM5
HPM2
Killark® Certilite® & Certilite® V - HZXTHKL
Pendant Ceiling Wall Stanchion
VMA2B & VMA-2 VMX2B & VMX-2 VMB2B & VMB-2 VMD4B
VMA3B & VMA-3 VMX3B & VMX-3 VMB3B & VMB-3 VMD5B
VMC2B & VMC-2 VMX6B VMS5B
VMC3B & VMC-3 VMX7B
VMF2B VMX8B
VMF3B VMX9B
GE Lighting Solutions – Filtr-Gard™ - HZXTHGE
Pendant Ceiling Wall Stanchion Quad Mount
3P 3F 3C 3W 5S
4P 4F 4C 4W 6S
5J
6J
STWXXXX models can be ordered with factory installed retrofit adapter by adding K, A, C, G, or M to the end of the part number. For example, STW8C2N becomes STW8C2NC. Please consult factory when ordering. Retrofit options are not suitable for use in Class I Div.1 environments
C = Eaton’s Crouse-Hinds – Champ® A = Appleton® Mercmaster III K = Killark® Certilite® & Certilite® V G = GE Lighting Solutions – Filtr-Gard™
memen5 INCEICI 204
Latazi
40/413PC r.O.LE ki0
NarOal
wompt4 hr t iff /Incas rallb]
DuroSite Industrial Application I Wal!pack
DuroSite® LED Wallpack / Bulkhead for Industrial applications
Ratings and Certifications
• UL 1598/A
• RoHS compliant • UL 8750
• CSA C22.2 NO.25 • CE
• 5yr full performance warranty • I P66/67 • L70 rated for >150,000 hours
"Al features not available on every model. Please refer to product part number pages for model specifics.
Mechanical information Specifications
Fixture weight: 16 lbs (5kg) Voltage options: 100 - 277V AC Housing: Copper free LM6 alum cast Shipping weight: 21Ibs (10kg) 24 - 48V DC Lens: High impact resistance clear Cable Entry: All cable entries are drilled Operating temp: glass
and tapped see ordering 11W / 22W -40°F to +140°F ( -40°C to +60°C) High impact resistance frosted options. 34W -40°F to +122°F ( -40°C to +50°C) glass
Power factor: >0.9 CRI: 75 THD: <20% CCT: 5650K (cool white)
Surge protection: 1 kV line to line, 2 kV line to ground 4300K (neutral white)
Lumens Wattage Im/W Mounting Heights
L70 2,250 34 66 20' >150,000 2,150 34 63
6,000 1,200 22 55 20,000 600 11 55 10' 24,000
Dial ight Wall pack / Bulkhead Metal Halide
High Pressure Sodium Fluorescent
Comparison
Warranty 5yr 1 1 1
Dimensions
Dimension are in mm [Inches]
Light Distributions
Narrow Optic
Oval Optic (55)(351
Oval Optic (35° x55°)
48 www.dialight.com
DuroSite Industrial Application|Wallpack
48 www.dialight.com
Dimensions
Light Distributions
Narrow Optic Oval Optic (55ox35o) Oval Optic (35o x55o)
Dimension are in mm [Inches]
Lumens Wattage lm/W Mounting Heights
2,250 34 66 20’
2,150 34 63
1,200 22 55
600 11 55 10’
Ratings and Certifications
• UL 1598/A • RoHS compliant
• UL 8750 • CSA C22.2 NO.25
• CE • 5yr full performance warranty
• IP66/67 • L70 rated for >150,000 hours
Mechanical information
Fixture weight: 16 lbs (5kg)
Shipping weight: 21lbs (10kg)
Cable Entry: All cable entries are drilled and tapped see ordering options.
Comparison
Warranty L70
Dialight Wallpack / Bulkhead 5yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Fluorescent 1 24,000
Specifications
Voltage options: 100 - 277V AC Housing: Copper free LM6 alum cast
24 - 48V DC Lens: High impact resistance clear
glassOperating temp:11W / 22W -40°F to +140°F (-40°C to +60°C) High impact resistance frosted
glass34W -40°F to +122°F (-40°C to +50°C)
Power factor: >0.9 CRI: 75
THD: <20% CCT: 5650K (cool white)
Surge protection: 1 kV line to line, 2 kV line to ground 4300K (neutral white)
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED Wallpack / Bulkheadfor Industrial applications
DuroSite Industrial Application I Wal!pack
DuroSite® LED Wallpack / Bulkhead Ordering Information and Mounting Accessories
Part Number Initial Fixture
Lumens Wattage Lm/W IP Rating Voltage
Colour Temperature (CCT)
Lens Light Distribution
Standard Models - 100 - 277V AC
WP-2C3L-NLGC 2,250 34 66 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Narrow
WP-4C3L-NLGC 2,250 34 66 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (35° X 55°)
WP-5C3L-NLGC 2,150 34 63 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
WP-2C3H-NLGC 1,200 22 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Narrow
WP-4C3H-NLGC 1,200 22 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (35° X 55°)
WP-5C3H-NLGC 1,200 22 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
WP-2C3C-NLGC 600 11 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Narrow
WP-4C3C-NLGC 600 11 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (35° X 55°)
WP-5C3C-NLGC 600 11 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
Standard Models - 24 - 48V DC
WP-2C2H-NLGC 1,200 22 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Narrow
WP-4C2H-NLGC 1,200 22 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Oval (35° X 55°)
WP-5C2H-NLGC 1,200 22 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
WP-2C2C-NLGC 600 11 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Narrow
WP-5C2C-NLGC 600 11 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%). Part number in table show fixture without a bracket. Al the codes listed above (expect for amber models) are cool white. For neutral white, change the "C" to "N" Ex: WP-4C3L-NLGC becomes WP-4N3L-NLGC. Angle bracket replace the 10th character with an W WP-2C3L-NLGC becomes WP-2N3L-ALGC Flush bracket replace the 10th character with a "F" WP-203L-NLGC becomes WP-2N3L-RGC Frosted glass models replace the 13th character with a "F" WP-203L-NLGC becomes WP-2C3L-NLGF (Frosted lens will reduce lumen output by 6%)
www.dialight.com 49
DuroSite Industrial Application|Wallpack
www.dialight.com 49
DuroSite® LED Wallpack / BulkheadOrdering Information and Mounting Accessories
Part NumberInitial Fixture
LumensWattage Lm/W IP Rating Voltage
Colour Temperature (CCT)
Lens Light Distribution
Standard Models - 100 - 277V AC
WP-2C3L-NLGC 2,250 34 66 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Narrow
WP-4C3L-NLGC 2,250 34 66 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (35° X 55°)
WP-5C3L-NLGC 2,150 34 63 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
WP-2C3H-NLGC 1,200 22 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Narrow
WP-4C3H-NLGC 1,200 22 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (35° X 55°)
WP-5C3H-NLGC 1,200 22 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
WP-2C3C-NLGC 600 11 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Narrow
WP-4C3C-NLGC 600 11 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (35° X 55°)
WP-5C3C-NLGC 600 11 55 IP66 100 - 277V AC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
Standard Models - 24 - 48V DC
WP-2C2H-NLGC 1,200 22 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Narrow
WP-4C2H-NLGC 1,200 22 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Oval (35° X 55°)
WP-5C2H-NLGC 1,200 22 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
WP-2C2C-NLGC 600 11 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Narrow
WP-5C2C-NLGC 600 11 55 IP66 24 - 48V DC 5650K (cool white) Clear Tempered glass Oval (55° X 35°)
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).Part number in table show fixture without a bracket.All the codes listed above (expect for amber models) are cool white. For neutral white, change the “C” to “N” Ex: WP-4C3L-NLGC becomes WP-4N3L-NLGC.Angle bracket replace the 10th character with an “A” WP-2C3L-NLGC becomes WP-2N3L-ALGCFlush bracket replace the 10th character with a “F” WP-2C3L-NLGC becomes WP-2N3L-FLGCFrosted glass models replace the 13th character with a “F” WP-2C3L-NLGC becomes WP-2C3L-NLGF (Frosted lens will reduce lumen output by 6%)
DuroSite
Industrial Application I Wal!pack
DuroSite® LED Wallpack / Bulkhead Ordering Information and Mounting Accessories
WP-BRKT-SS-ADJ • Adjustable Bracket • Includes self-tapping
screws
WP-STMB-LG85-22 • 1 1/2" BSP threaded 85 degree stanchion
mounting bracket
WP-STMB-LG85-24 • 1 1/2" NPT threaded 85 degree stanchion
mounting bracket
WP-STMB-LG85-50 • Non threaded bore 34mm diameter WP-STMB-LG85-60 • Non threaded bore 38mm diameter
WP-STMB-LG25-22 • 1 1/2" BSP threaded 25 degree
stanchion mounting bracket
WP-STMB-LG25-24 • 1 1/2" NPT threaded 25 degree
stanchion mounting bracket
WP-STMB-LGOO- 22 • 1 1/2" BSP threaded straight stanchion
mounting bracket
WP-STMB-LGOO -24 • 1 1/2" NPT threaded straight stanchion
mounting bracket
WP-BRKT-LG-PF • Pipe and flush bracket • Includes self-tapping screws
WP-RECESS-WH • Recessed housing
• Bracket to fixture hardware
WPX-000799-BATT • 10Ah 3.6V Battery Module
• Replacement Battery Kit
• Battery Backup models only
Entry Options Standard Option 2 Entries One Side
Option "E" 2 Entries One Side, 1 Entry
Opposite Side. Add E to the end of the order code
option "R" Add R to the end of the
order code
Option "H" 2 Entries One Side, 2 Entries Opposite Side and
1 Entry in the Rear Add H to the end of the order code
UPI
50
www.dialight.com
DuroSite Industrial Application|Wallpack
50 www.dialight.com
DuroSite® LED Wallpack / BulkheadOrdering Information and Mounting Accessories
WP-STMB-LG00- 22• 1 1/2” BSP threaded straight stanchion
mounting bracket
WP-STMB-LG00 -24• 1 1/2” NPT threaded straight stanchion
mounting bracket
WP-BRKT-SS-ADJ• Adjustable Bracket• Includes self-tapping
screws
WP-BRKT-LG-PF• Pipe and flush bracket• Includes self-tapping screws
WP-STMB-LG85-22• 1 1/2” BSP threaded 85 degree stanchion
mounting bracket
WP-STMB-LG85-24• 1 1/2” NPT threaded 85 degree stanchion
mounting bracket
WP-STMB-LG85-50• Non threaded bore 34mm diameterWP-STMB-LG85-60• Non threaded bore 38mm diameter
WP-STMB-LG25-22• 1 1/2” BSP threaded 25 degree
stanchion mounting bracket
WP-STMB-LG25-24 • 1 1/2” NPT threaded 25 degree
stanchion mounting bracket
WPX-000799-BATT• 10Ah 3.6V Battery Module
• Replacement Battery Kit
• Battery Backup models only
WP-RECESS-WH• Recessed housing
• Bracket to fixture hardware
Standard Option 2 Entries One Side
Option “E”2 Entries One Side, 1 Entry
Opposite Side. Add E to the end of the order code
Option “R”Add R to the end of the
order code
Entry OptionsOption “H”
2 Entries One Side, 2 Entries Opposite Side and 1 Entry in the Rear
Add H to the end of the order code
of u
1
illio° I' ! II -.'
RTO-OWxx-004
Dimension are in Inches [mm] RTO-OW)a-005 RTO-OW>c<-001
DuroSite
Industrial Application I Area Light
DuroSite® LED RTO Area Light for Industrial application;
Ratings and Certifications
• UL 1598/A
• CSA 22.2 No. 137-M1981 • IP66
• 5yr full performance warranty • NEMA 4X • L70 rated for >150,000 hours
"All features not available on every model. Please refer to product part number pages for model specifics.
Mechanical information
Fixture weight: RTOOWxx001: RTOOWxx005: RTOOWxx004: Shipping weight: RTOOWxx001: RTOOWxx005: RTOOWxx004:
Mounting: Pendant mount: Ceiling mount: Pendant mount:
Voltage options:
Operating temp:
Power factor: THD: Surge protection:
Specifications 100 - 277V AC
Housing: 24 - 48V DC
Lens: -40°F to +133°F
CRI: (-40°C to +55°C)
CCT: >0.9 <20% 1 kV line to line, 2 kV line to ground
Copper free aluminum Polycarbonate 75
6000K (cool white)
2.5 lbs (1.13 kg) 3.2 lbs (1.45 kg)
0.8 lbs (0.36 Kg)
3.0 lbs (1.36 kg) 4.5 lbs (2.04 kg)
1.4 lbs (0.64 Kg)
1" & 3/4" NPT reducer bi-directional mounting
3/4" NPT 5-way surface mounting 3/4" NPT threaded conduit
Dialight RTO Area Light Metal Halide
High Pressure Sodium Fluorescent
Comparison
Warranty L70 Lumens
800
Wattage
8 5yr >150,000 470 8 1 6,000 1 20,000 1 24,000
Im/W
Mounting Heights
100
15' and lower 59
Dimensions
Light Distribution Pattern
www.dialight.com 51
DuroSite Industrial Application| Area Light
www.dialight.com 51
Dimensions
RTO-0Wxx-001 RTO-0Wxx-005 RTO-0Wxx-004
Light Distribution Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
800 8 100 15’ and lower
470 8 59
Ratings and Certifications
• UL 1598/A • CSA 22.2 No. 137-M1981
• IP66 • 5yr full performance warranty
• NEMA 4X • L70 rated for >150,000 hours
Mechanical information
Fixture weight:RTO0Wxx001: 2.5 lbs (1.13 kg)
RTO0Wxx005: 3.2 lbs (1.45 kg)
RTO0Wxx004: 0.8 lbs (0.36 Kg)
Shipping weight:RTO0Wxx001: 3.0 lbs (1.36 kg)
RTO0Wxx005: 4.5 lbs (2.04 kg)
RTO0Wxx004: 1.4 lbs (0.64 Kg)
Mounting:Pendant mount: 1” & 3/4” NPT reducer bi-directional mounting
Ceiling mount: 3/4” NPT 5-way surface mounting
Pendant mount: 3/4” NPT threaded conduit
Comparison
Warranty L70
Dialight RTO Area Light 5yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Fluorescent 1 24,000
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
24 - 48V DC Lens: Polycarbonate
Operating temp: -40°F to +133°F CRI: 75
(-40°C to +55°C) CCT: 6000K (cool white)
Power factor: >0.9
THD: <20%
Surge protection: 1 kV line to line, 2 kV line to ground
*All features not available on every model. Please refer to product part number pages for model specifics.
DuroSite® LED RTO Area Lightfor Industrial applications
DuroSite
Industrial Application I Area Light
DuroSite® LED RTO Area Light Ordering Information and Mounting Accessories
Part Number Type Fixture Lumen
LPW Warranty Voltage CCT Lens Light
Distribution Pattern
Standard models - 100 - 277V AC
RTOOW17005 Ceiling mount with junction box 800 8 100 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTOOW17004 Pendant mount 800 8 100 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTOOW17001 Pendant mount with junction box 800 8 100 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTOOW07005 Ceiling mount with junction box 470 8 59 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTOOW07004 Pendant mount 470 8 59 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTOOW07001 Pendant mount with junction box 470 8 59 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
Standard Models - 24 - 48V DC
RTOOW18005 Ceiling mount with junction box 800 8 100 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTOOW18004 Pendant mount 800 8 100 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTOOW18001 Pendant mount with junction box 800 8 100 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTOOW08005 Ceiling mount with junction box 470 8 59 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTOOW08004 Pendant mount 470 8 59 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTOOW08001 Pendant mount with junction box 470 8 59 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Pendant Mount • 3/4" NPT threaded conduit
RT01000 • Flush wall mount
Pendant Mount with Junction Box • 1" & 3/4" NPT reducer bi-
directional mounting
RT01001 • Junction box wall mount
Ceiling Mount with Junction Box • 3/4" 5-way surface
mounting
52
www.dialight.com
DuroSite Industrial Application| Area Light
52 www.dialight.com
Part Number TypeFixture Lumen
Watt LPW Warranty Voltage CCT LensLight
Distribution Pattern
Standard models - 100 - 277V AC
RTO0W17005 Ceiling mount with junction box 800 8 100 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTO0W17004 Pendant mount 800 8 100 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTO0W17001 Pendant mount with junction box 800 8 100 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTO0W07005 Ceiling mount with junction box 470 8 59 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTO0W07004 Pendant mount 470 8 59 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
RTO0W07001 Pendant mount with junction box 470 8 59 5 yr 100-277V AC 6000K (cool white) Clear Polycarbonate Circular
Standard Models - 24 - 48V DC
RTO0W18005 Ceiling mount with junction box 800 8 100 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTO0W18004 Pendant mount 800 8 100 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTO0W18001 Pendant mount with junction box 800 8 100 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTO0W08005 Ceiling mount with junction box 470 8 59 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTO0W08004 Pendant mount 470 8 59 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
RTO0W08001 Pendant mount with junction box 470 8 59 5yr 24 - 48V DC 6000K (cool white) Clear Polycarbonate Circular
DuroSite® LED RTO Area LightOrdering Information and Mounting Accessories
Pendant Mount with Junction Box• 1’’ & 3/4’’ NPT reducer bi-
directional mounting
Ceiling Mount with Junction Box• 3/4’’ 5-way surface
mounting
Pendant Mount• 3/4’’ NPT threaded conduit
RTO1001• Junction box wall mount
RTO1000• Flush wall mount
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Hazardous Locations Ratings Fixed and portable fixtures for installation and use in hazardous (classified) locations Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class Ill, Divisions 1 and 2, in accordance with the National Electrical Code, NFPA 70
Classes The classes define the general nature of hazardous material in the surrounding atmosphere.
Class
Hazardous Material in Surrounding Atmosphere
Class I
Hazardous because flammable gases or vapors are present in the air in quantities sufficient to produce explosive or ignitable mixtures.
Class II
Hazardous because combustible or conductive dusts are present.
Class Ill
Hazardous because ignitable fibers or flying's are present, but not likely to be in suspension in sufficient quantities to produce ignitable mixtures. Typical wood chips, cotton, flax and nylon. Group classifications are not applied to this class.
Divisions The division defines the probability of hazardous material being present in an ignitable concentration in the surrounding atmosphere.
Division
Presence of Hazardous Material
Division 1
The substance referred to by class is present during normal conditions.
The substance referred to by class is present only in abnormal conditions, such as a container failure or system breakdown. Division 2
Groups The group defines the hazardous material in the surrounding atmosphere.
Group
Hazardous Material in Surrounding Atmosphere
Group A
Acetylene
Group B
Hydrogen, fuel and combustible process gases containing more than 30% hydrogen by volume or gases of equivalent hazard such as butadiene, ethylene, oxide, propylene oxide and acrolein.
Group C
Carbon monoxide, ether, hydrogen sulfide, morphline, cyclopropane, ethyl and ethylene or gases of equivalent hazard.
Group D
Gasoline, acetone, ammonia, benzene, butane, cyclopropane, ethanol, hexane, methanol, methane, vinyl chloride, natural gas, naphtha, propane or gases of equivalent hazard.
Group E
Combustible metal dusts, including aluminum, magnesium and their commercial alloys or other combustible dusts whose particle size, abrasiveness and conductivity present similar hazards in connection with electrical equipment.
Group F
Carbonaceous dusts, carbon black, coal black, charcoal, coal or coke dusts that have more than 8% total entrapped volatiles or dusts that have been sesitized by other material so they present an explosion hazard.
Group G
Flour dust, grain dust, flour, starch, sugar, wood, plastic and chemicals.
Reference: http://vwwv.engineeringtoolbox.com/hazardous-areas-classification-d_347.html
www.dialight.com
53 www.dialight.com 53
Hazardous Locations RatingsFixed and portable fixtures for installation and use in hazardous (classified) locations Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III, Divisions 1 and 2, in accordance with the National Electrical Code, NFPA 70
Classes The classes define the general nature of hazardous material in the surrounding atmosphere.
Class Hazardous Material in Surrounding Atmosphere
Class I Hazardous because flammable gases or vapors are present in the air in quantities sufficient to produce explosive or ignitable mixtures.
Class II Hazardous because combustible or conductive dusts are present.
Class IIIHazardous because ignitable fibers or flying’s are present, but not likely to be in suspension in sufficient quantities to produce ignitable mixtures.
Typical wood chips, cotton, flax and nylon. Group classifications are not applied to this class.
Divisions The division defines the probability of hazardous material being present in an ignitable concentration in the surrounding atmosphere.
Division Presence of Hazardous Material
Division 1 The substance referred to by class is present during normal conditions.
Division 2 The substance referred to by class is present only in abnormal conditions, such as a container failure or system breakdown.
Groups The group defines the hazardous material in the surrounding atmosphere.
Group Hazardous Material in Surrounding Atmosphere
Group A Acetylene
Group BHydrogen, fuel and combustible process gases containing more than 30% hydrogen by volume or gases of equivalent hazard such as butadiene,
ethylene, oxide, propylene oxide and acrolein.
Group C Carbon monoxide, ether, hydrogen sulfide, morphline, cyclopropane, ethyl and ethylene or gases of equivalent hazard.
Group DGasoline, acetone, ammonia, benzene, butane, cyclopropane, ethanol, hexane, methanol, methane, vinyl chloride, natural gas, naphtha, propane or
gases of equivalent hazard.
Group ECombustible metal dusts, including aluminum, magnesium and their commercial alloys or other combustible dusts whose particle size, abrasiveness
and conductivity present similar hazards in connection with electrical equipment.
Group FCarbonaceous dusts, carbon black, coal black, charcoal, coal or coke dusts that have more than 8% total entrapped volatiles or dusts that have
been sesitized by other material so they present an explosion hazard.
Group G Flour dust, grain dust, flour, starch, sugar, wood, plastic and chemicals.
Reference:http://www.engineeringtoolbox.com/hazardous-areas-classification-d_347.html
Dimensions
1625 1.88
5/16--18.x.75- [406.401 11-1KADED 121
[412.ei
Dimension are in Inches [mm]
1.9 WY HP1 MEADS
r49)
PRI
11:r 1.3.05m.1 POWER COW
frirw • 1.11.10.5" THREACIED HOLE 1211-
it
III,.. .
MI` a 1-1
1.95 (49.5A
[76-20
Circular Pattern
SafeSite
Hazardous Application I High Bay
SafeSite® LED High Bay - High Efficiency for Hazardous applications
Ratings and Certifications
• UL 844
• C22.2 No.137-M81
• CIID1 E,F,G
• UL 1598/A
• CID1 C,D
• 10yr full performance warranty
• IP66
• CIID1 E,F,G
• L70 rated for >150,000 hours
• NEMA 4X
• CID2 A,B,C,D "AI features not available on every model. Please refer to product part number pages for model specifics.
Temperature Ratings
Ambient Temperature Range Ambient Temperature Range T4 Temperature Code T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +122°F (-40°C to +50°C)
Voltage options:
110 - 277V AC
100 - 277V AC
Operating temp:
Power factor:
THD:
Surge protection:
,thanical information
Fixture weight: HED / HEF 18 lbs HEC / HEM 30 lbs
Shipping weight:
HED / HEF 24 lbs
HEC / HEM 34 lbs
Mounting: (1) 3/4" NPT - top
(2) 5/16"-18 x .75" UNC - side
Cabling: 10' (3.05m) STOOW Power Cord
Specifications
26,5001m models
18,000, 14,000 & 11,000Im models
-40°F to +149°F (-40°C to +65°C)
>0.9
<20%
Protection devices capable of handling up to 6kV. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
Housing:
Lens options:
CRI:
CCT:
Copper free aluminum
Tempered glass - UL1598
75
5000K (cool white)
4000K (neutral white)
Dialight High Bay
Metal Halide
High Pressure Sodium
Comparison Warranty L70
10yr >150,000
1 6,000
1 20,000
T-Rating T5
T2
T2A
Lumens
26,500 18,000 14,000 11,000
Wattage 212 144 112
88
Im/W
125 125 125 125
Mounting Heights
50' +
20'
Light Distribution Pattern
54 www.dialight.com
SafeSite Hazardous Application| High Bay
54 www.dialight.com
Dimensions
Light Distribution Pattern
Plane & ConeCATALOG NUMBER: 1ST PRODUCTION UNIT
FILENAME: MIDHIGHBAY 25.IES
MAX CANDLEPOWER: 11359.6 Max plane at H = 45 Max cone at V = 30
Reported data calculated from manufacturer's data file, based on IESNA recommended methods.
Photometric Viewer v3.4
Circular Pattern Wide Pattern
Temperature Ratings
Ambient Temperature RangeT4 Temperature Code
Ambient Temperature RangeT5 Temperature Code
-40oF to +149oF (-40oC to +65oC) -40oF to +122oF (-40oC to +50oC)
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
26,500 212 125 50’ +
18,000 144 125
14,000 112 125
11,000 88 125 20’
Ratings and Certifications
• UL 844 • C22.2 No.137-M81 • CIID1 E,F,G
• UL 1598/A • CID1 C,D • 10yr full performance warranty
• IP66 • CIID1 E,F,G • L70 rated for >150,000 hours
• NEMA 4X • CID2 A,B,C,D
Mechanical information
Fixture weight:HED / HEF 18 lbs
HEC / HEM 30 lbs
Shipping weight:
HED / HEF 24 lbs
HEC / HEM 34 lbs
Mounting: (1) 3/4” NPT - top
(2) 5/16”-18 x .75” UNC - side
Cabling: 10’ (3.05m) STOOW Power Cord
ComparisonWarranty L70 T-Rating
Dialight High Bay 10yr >150,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Specifications
Voltage options:
110 – 277V AC 26,500lm models Housing: Copper free aluminum
100 – 277V AC 18,000, 14,000 & 11,000lm models Lens options: Tempered glass - UL1598
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% 4000K (neutral white)
Surge protection: Protection devices capable of handling up to 6kV. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED High Bay - High Efficiencyfor Hazardous applications
CID2 / ClID1 Models
• • 100-277V AC Clear Polycarbonate
• • 100-277V AC Clear Polycarbonate
• • 100-277V AC Clear Polycarbonate
• • 100-277V AC Clear Polycarbonate
• • 100-277V AC Clear Polycarbonate
• • 100-277V AC Clear Polycarbonate
SafeSite Hazardous Application I High Bay
SafeSite® LED High Bay - High Efficiency Class I Div 1 / Class II Div 1 models - Ordering Information
Classifications: CID1 C, D • CID2 Groups A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
Part Number CID1 CID2 ClID1 CIID2 Voltage
Lens CCT Fixture Lumens
ig Distribution
CID2 Models
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
HEDGMC4PN-SSG
HEDGMC4PN-SNG
HEDGRC4PN-SSG
HEDGRC4PN-SNG
HEDGMC4KN-SSG
HEDGMC4KN-SNG
HEDGRC4KN-SSG
HEDGRC4KN-SNG
HEDGMC4GN-SSG
HEDGMC4GN-SNG
HEDGRC4GN-SSG
HEDGRC4GN-SNG
HEDGMC4DN-SSG
HEDGMC4DN-SNG
HEDGRC4DN-SSG
HEDGRC4DN-SNG
HEF2MC4KN-SNG
HEF2MC4KN-SSG
HEF2MC4GN-SNG
HEF2MC4GN-SSG
HEF2MC4DN-SNG
HEF2MC4DN-SSG
All values 1ypical
• • 110-277V AC
• • • 110-277V AC
• • 110-277V AC
• • • 110-277V AC
• • 100-277V AC
• • • 100-277V AC
• • 100-277V AC
• • • 100-277V AC
• • 100-277V AC
• • • 100-277V AC
• • 100-277V AC
• • • 100-277V AC
• • 100-277V AC
• • • 100-277V AC
• • 100-277V AC
• • • 100-277V AC
•
•
• I irn.n nro hirsired ffnl.rance +/- 10%).
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
▪ 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
26,500 212 125 Circular
26,500 212 125 Circular
26,500 212 125 Wide
26,500 212 125 Wide
18,000 144 125 Circular
18,000 144 125 Circular
18,000 144 125 Wide
18,000 144 125 Wide
14,000 112 125 Circular
14,000 112 125 Circular
14,000 112 125 Wide
14,000 112 125 Wide
11,000 88 125 Circular
11,000 88 125 Circular
11,000 88 125 Wide
11,000 88 125 Wide
14,750 144 102 Circular
14,750 144 102 Circular
11,500 112 102 Circular
11,500 112 102 Circular
9,000 88 102 Circular
9,000 88 102 Circular
All models shown in the table are Cool White, for models in Neutral 4000K CCT replace the 5th character with an N. Example: HEC9MC4PN-SNG becomes HEC9MN4PN-SNG. Deduct 8% from lumen values when specifying neutral.
www.dialight.com 55
SafeSite Hazardous Application| High Bay
www.dialight.com 55
SafeSite® LED High Bay - High EfficiencyClass I Div 1 / Class II Div 1 models - Ordering Information
Classifications: CID1 C, D • CID2 Groups A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
Part Number CID1 CID2 CIID1 CIID2 CIII Voltage LensSafety bracket
CCTFixtureLumens
Watt LPWLight
Distribution Pattern
CID2 Models
HEDGMC4PN-SSG • • • 110-277V AC Tempered glass • 5000K (cool white) 26,500 212 125 Circular
HEDGMC4PN-SNG • • • 110-277V AC Tempered glass 5000K (cool white) 26,500 212 125 Circular
HEDGRC4PN-SSG • • • 110-277V AC Tempered glass • 5000K (cool white) 26,500 212 125 Wide
HEDGRC4PN-SNG • • • 110-277V AC Tempered glass 5000K (cool white) 26,500 212 125 Wide
HEDGMC4KN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 18,000 144 125 Circular
HEDGMC4KN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 18,000 144 125 Circular
HEDGRC4KN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 18,000 144 125 Wide
HEDGRC4KN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 18,000 144 125 Wide
HEDGMC4GN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 14,000 112 125 Circular
HEDGMC4GN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 14,000 112 125 Circular
HEDGRC4GN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 14,000 112 125 Wide
HEDGRC4GN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 14,000 112 125 Wide
HEDGMC4DN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 11,000 88 125 Circular
HEDGMC4DN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 11,000 88 125 Circular
HEDGRC4DN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 11,000 88 125 Wide
HEDGRC4DN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 11,000 88 125 Wide
CID2 / CIID1 Models
HEF2MC4KN-SNG • • • • 100-277V AC Clear Polycarbonate 5000K (cool white) 14,750 144 102 Circular
HEF2MC4KN-SSG • • • • 100-277V AC Clear Polycarbonate • 5000K (cool white) 14,750 144 102 Circular
HEF2MC4GN-SNG • • • • 100-277V AC Clear Polycarbonate 5000K (cool white) 11,500 112 102 Circular
HEF2MC4GN-SSG • • • • 100-277V AC Clear Polycarbonate • 5000K (cool white) 11,500 112 102 Circular
HEF2MC4DN-SNG • • • • 100-277V AC Clear Polycarbonate 5000K (cool white) 9,000 88 102 Circular
HEF2MC4DN-SSG • • • • 100-277V AC Clear Polycarbonate • 5000K (cool white) 9,000 88 102 Circular
All models shown in the table are Cool White, for models in Neutral 4000K CCT replace the 5th character with an N. Example: HEC9MC4PN-SNG becomes HEC9MN4PN-SNG. Deduct 8% from lumen values when specifying neutral.
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
CID1 Models
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
Tempered glass
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
• 5000K (cool white)
5000K (cool white)
Illllllllllli
5000K (cool white)
SafeSite
Hazardous Application I High Bay
SafeSite® LED High Bay - High Efficiency - UL 844 Class I, Div 1 - Ordering Information
Classifications: CID1 C, D • CIID1 E, F, G
Part Number CID1 CID2 ClID1 CIID2
HEC9MC4PN-SNG
HEC9MC4PN-SSG
HEC9RC4PN-SNG
HEC9RC4PN-SSG
HEC9MC4KN-SNG
HEC9MC4KN-SSG
HEC9RC4KN-SNG
HEC9RC4KN-SSG
HEC9MC4GN-SNG
HEC9MC4GN-SSG
HEC9RC4GN-SNG
HEC9RC4GN-SSG
HEC9MC4DN-SNG
HEC9MC4DN-SSG
HEC9RC4DN-SNG
HEC9RC4DN-SSG
HEM9RC4PN-SNG •
HEM9RC4PN-SSG • •
HEM9NC4PN-SNG •
HEM9NC4PN-SSG • •
HEM9MC4PN-SNG •
HEM9MC4PN-SSG • •
HEM9NC4KN-SNG •
HEM9NC4KN-SSG • •
HEM9MC4KN-SNG •
HEM9MC4KN-SSG • •
HEM9RC4KN-SNG •
HEM9RC4KN-SSG • •
HEM9NC4GN-SNG •
HEM9NC4GN-SSG • •
HEM9RC4GN-SNG •
HEM9RC4GN-SSG • •
HEM9MC4GN-SNG •
HEM9MC4GN-SSG • •
HEM9NC4DNSNG •
HEM9NC4DNSSG • •
HEM9MC4DN-SNG •
HEM9MC4DN-SSG • •
HEM9RC4DN-SNG •
HEM9RC4DN-SSG • •
Voltage
110-277V AC
110-277V AC
110-277V AC
110-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
110-277V AC
110-277V AC
110-277V AC
110-277V AC
110-277V AC
110-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
100-277V AC
Lens CCT Fixture Lumens
ig t Distribution
23,500 212 110 Circular
23,500 212 110 Circular
22,250 212 105 Wide
22,250 212 105 Wide
16,000 144 110 Circular
16,000 144 110 Circular
15,250 144 105 Wide
15,250 144 105 Wide
12,500 112 110 Circular
12,500 112 110 Circular
11,750 112 105 Wide
11,750 112 105 Wide
9,650 88 110 Circular
9,650 88 110 Circular
9,250 88 105 Wide
9,250 88 105 Wide
23,500 212 110 Wide
23,500 212 110 Wide
23,500 212 110 Narrow
23,500 212 110 Narrow
23,500 212 110 Circular
23,500 212 110 Circular
17,000 144 118 Narrow
17,000 144 118 Narrow
16,000 144 110 Circular
16,000 144 110 Circular
16,000 144 110 Wide
15,250 144 110 Wide
13,000 112 115 Narrow
13,000 112 115 Narrow
12,250 112 110 Wide
12,250 112 110 Wide
12,250 112 110 Circular
12,250 112 110 Circular
10,250 88 115 Narrow
10,250 88 115 Narrow
9,750 88 110 Circular
9,750 88 110 Circular
9,250 88 105 Wide
9,250 88 105 Wide
CID1 Models - Paint Spray Rated
All values typical unless -""-t Lumen values are typical (tolerance +/- 10%). All models shown in the table are Cool White, for models in Neutral 4000K CCT replace the 5 th character with an N. Example: HEC9MC4PN-SNG becomes HEC9M11.14PN-SNG. Deduct 8% from lumen values when specifying neutral.
56 www.dialight.com
SafeSite Hazardous Application| High Bay
56 www.dialight.com
SafeSite® LED High Bay - High Efficiency - UL 844Class I, Div 1 - Ordering Information
All models shown in the table are Cool White, for models in Neutral 4000K CCT replace the 5th character with an N. Example: HEC9MC4PN-SNG becomes HEC9MN4PN-SNG. Deduct 8% from lumen values when specifying neutral.
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Classifications: CID1 C, D • CIID1 E, F, G
Part Number CID1 CID2 CIID1 CIID2 CIII Voltage LensSafety bracket
CCTFixtureLumens
Watt LPWLight
Distribution Pattern
CID1 Models
HEC9MC4PN-SNG • • • 110-277V AC Tempered glass 5000K (cool white) 23,500 212 110 Circular
HEC9MC4PN-SSG • • • 110-277V AC Tempered glass • 5000K (cool white) 23,500 212 110 Circular
HEC9RC4PN-SNG • • • 110-277V AC Tempered glass 5000K (cool white) 22,250 212 105 Wide
HEC9RC4PN-SSG • • • 110-277V AC Tempered glass • 5000K (cool white) 22,250 212 105 Wide
HEC9MC4KN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 16,000 144 110 Circular
HEC9MC4KN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 16,000 144 110 Circular
HEC9RC4KN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 15,250 144 105 Wide
HEC9RC4KN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 15,250 144 105 Wide
HEC9MC4GN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 12,500 112 110 Circular
HEC9MC4GN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 12,500 112 110 Circular
HEC9RC4GN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 11,750 112 105 Wide
HEC9RC4GN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 11,750 112 105 Wide
HEC9MC4DN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 9,650 88 110 Circular
HEC9MC4DN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 9,650 88 110 Circular
HEC9RC4DN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 9,250 88 105 Wide
HEC9RC4DN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 9,250 88 105 Wide
CID1 Models - Paint Spray Rated
HEM9RC4PN-SNG • • • 110-277V AC Tempered glass 5000K (cool white) 23,500 212 110 Wide
HEM9RC4PN-SSG • • • 110-277V AC Tempered glass • 5000K (cool white) 23,500 212 110 Wide
HEM9NC4PN-SNG • • • 110-277V AC Tempered glass 5000K (cool white) 23,500 212 110 Narrow
HEM9NC4PN-SSG • • • 110-277V AC Tempered glass • 5000K (cool white) 23,500 212 110 Narrow
HEM9MC4PN-SNG • • • 110-277V AC Tempered glass 5000K (cool white) 23,500 212 110 Circular
HEM9MC4PN-SSG • • • 110-277V AC Tempered glass • 5000K (cool white) 23,500 212 110 Circular
HEM9NC4KN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 17,000 144 118 Narrow
HEM9NC4KN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 17,000 144 118 Narrow
HEM9MC4KN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 16,000 144 110 Circular
HEM9MC4KN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 16,000 144 110 Circular
HEM9RC4KN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 16,000 144 110 Wide
HEM9RC4KN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 15,250 144 110 Wide
HEM9NC4GN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 13,000 112 115 Narrow
HEM9NC4GN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 13,000 112 115 Narrow
HEM9RC4GN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 12,250 112 110 Wide
HEM9RC4GN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 12,250 112 110 Wide
HEM9MC4GN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 12,250 112 110 Circular
HEM9MC4GN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 12,250 112 110 Circular
HEM9NC4DNSNG • • • 100-277V AC Tempered glass 5000K (cool white) 10,250 88 115 Narrow
HEM9NC4DNSSG • • • 100-277V AC Tempered glass • 5000K (cool white) 10,250 88 115 Narrow
HEM9MC4DN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 9,750 88 110 Circular
HEM9MC4DN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 9,750 88 110 Circular
HEM9RC4DN-SNG • • • 100-277V AC Tempered glass 5000K (cool white) 9,250 88 105 Wide
HEM9RC4DN-SSG • • • 100-277V AC Tempered glass • 5000K (cool white) 9,250 88 105 Wide
SafeSite
Hazardous Application I High Bay
SafeSite® LED High Bay - High Efficiency Ordering Information and Mounting Accessories
Suitable for: CID1 • CID2 HBXW1 • Wall mount
Suitable for: CID2 HBXW2 • Swivel bracket and cable gland
Suitable for: CID2
HBXCG • Cable gland
Suitable for: CID2
HBX-DUAL-BRCKT • Dual bracket
Suitable for: CID1 CID2
HBXC1 • Ceiling mount
Suitable for: CID1 • CID2
HBXW3-SSL-316 • Stainless steel swivel bracket • 316 Stainless steel
HBXW3-SSL-304 • Stainless steel swivel bracket • 304 Stainless steel
www.dialight.com 57
SafeSite Hazardous Application| High Bay
www.dialight.com 57
SafeSite® LED High Bay - High EfficiencyOrdering Information and Mounting Accessories
HBXW2• Swivel bracket and cable gland
HBXC1• Ceiling mount
HBXW1• Wall mount
HBX-DUAL-BRCKT• Dual bracket
HBXW3-SSL-316• Stainless steel swivel bracket• 316 Stainless steel
HBXW3-SSL-304• Stainless steel swivel bracket• 304 Stainless steel
HBXCG• Cable gland
Suitable for: CID1 • CID2 Suitable for: CID2
Suitable for: CID2 Suitable for: CID2
Suitable for: CID1 • CID2 Suitable for: CID1 • CID2
Specifications
Voltage options:
Operating temp:
Power factor:
THD:
Surge protection:
100 - 277V AC
347 - 480V AC
See Temperature chart below
>0.9
<20%
Protection devices capable of handling up to 6kV. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
Housing:
Lens options:
CRI:
CCT:
Copper free aluminum
Tempered glass
70
5000K (cool white)
4000K (neutral white)
Mechanical information
Fixture weight:
HBO / HBM 30 lbs (14 kg)
HBD 17 lbs (8 kg)
HBP 32 lbs (15 kg)
Shipping weight:
HBO / HBM
35 lbs (16kg)
HBD
22 lbs (10kg)
HBP
37 lbs (17kg)
Mounting:
(1) 3/4" NPT - top
(2) 5/16"-18 x .75" UNC - side
Cabling:
10' (3.05m) STOOW Power Cord
Comparison Warranty L70
Dialight High Bay 10/5yr >150,000
Metal Halide 1 6,000
High Pressure Sodium 1 20,000
'murrain hum "!WY' II ao K4)5)
VW • la k7r 11-MACC FP= (2:1q
10113.0fel PenkER CCQ13
Dimension are in Inches [mm]
4 31'4' PVT 11111V1S
149F
SafeSite
Hazardous Application I High Bay
SafeSite® LED High Bay for Hazardous applications
• UL 844
• UL 1598/A
• IP66
• NEMA 4X
HBO / HBM
HBP
HBD / HBF
Ratings and Certifications
• CID1 B,C,D
• CID2 A,B,C,D
• CIID1 E,F,G
• ClID2 F,G
Temperature Ratings
Ambient Temperature Range ( T4A Temperature Code)
-40F to +149F (-40C to +65C)
-40F to +140F (-40C to +60C)
• CIII
• Group B Hydrogen
• 10 / 5yr full performance warranty
• L70 rated for >150,000 hours "All features not available on every model. Please refer to product part number pages for model specifics.
Ambient Temperature Range (T5 Temperature Code)
-40F to +131F (-40C to +55C)
-40F to +149F (-40C to +65C)
-40F to +104F (-40C to +40C)
Lumens Wattage Im/W Mounting Heights
25,000 270 93 50' T-Rating 17,500 170 103
T5 14,500 172 85 T2 10,500 146 72
T2A 8,500 123 69 20'
)imensions
Light Distribution Pattern
58 www.dialight.com
SafeSite Hazardous Application| High Bay
58 www.dialight.com
Dimensions
Light Distribution Pattern
Temperature Ratings
Ambient Temperature Range ( T4A Temperature Code)
Ambient Temperature Range (T5 Temperature Code)
HBC / HBM -40F to +149F (-40C to +65C) -40F to +131F (-40C to +55C)
HBP -40F to +149F (-40C to +65C)
HBD / HBF -40F to +140F (-40C to +60C) -40F to +104F (-40C to +40C)
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
25,000 270 93 50’
17,500 170 103
14,500 172 85
10,500 146 72
8,500 123 69 20’
Ratings and Certifications
• UL 844 • CID1 B,C,D • CIII
• UL 1598/A • CID2 A,B,C,D • Group B Hydrogen
• IP66 • CIID1 E,F,G • 10 / 5yr full performance warranty
• NEMA 4X • CIID2 F,G • L70 rated for >150,000 hours
Mechanical information
Fixture weight:
HBC / HBM 30 lbs (14 kg)
HBD 17 lbs (8 kg)
HBP 32 lbs (15 kg)
Shipping weight:
HBC / HBM 35 lbs (16kg)
HBD 22 lbs (10kg)
HBP 37 lbs (17kg)
Mounting: (1) 3/4” NPT - top
(2) 5/16”-18 x .75” UNC - side
Cabling: 10’ (3.05m) STOOW Power Cord
ComparisonWarranty L70 T-Rating
Dialight High Bay 10 / 5yr >150,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
347 - 480V AC Lens options: Tempered glass
Operating temp: See Temperature chart below CRI: 70
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% 4000K (neutral white)
Surge protection: Protection devices capable of handling up to 6kV. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED High Bay for Hazardous applications
SafeSite
Hazardous Application I High Bay
SafeSite® LED High Bay Ordering Information and Mounting Accessories Classifications: CID1 C, D • CID2 Groups A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
Part Number CID1 CID2 CIID1 ClID2 Voltage Lens Warranty CCT Fixture
Lumens
Standard Models - 100 - 277V AC
HBP9C3M • 100-277V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBM9C3M • • • 100-277V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBM8C3G • 100-277V AC Clear Tempered glass 5yr 5000K (cool white) 5,500 146 38
Standard Models - 347 - 480V AC
HBDGCTN • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 17,000 172 99
HBC9CTN • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 14,500 172 84
HBDGCSN • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 14,000 161 87
HBF2C5N • • • 347-480V AC Diffused Polycarbonate 5yr 5000K (cool white) 12,000 161 75
HBD2C5N • • • 347-480V AC Clear Polycarbonate 5yr 5000K (cool white) 12,000 161 75
HBC9C6N • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 11,000 161 68
HBF2C5M • • • 347-480V AC Diffused Polycarbonate 5yr 5000K (cool white) 10,500 146 72
HBD2C5M • • • 347-480V AC Clear Polycarbonate 5yr 5000K (cool white) 10,500 146 72
HBP9C6M • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBM9C6M • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBC9C6M • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBF3C5L • • • 347-480V AC Diffused Polycarbonate 5yr 5000K (cool white) 8,500 124 69
HBD3C5L • • • 347-480V AC Diffused Glass 5yr 5000K (cool white) 8,500 124 69
HBC8C6G • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 5,500 146 38
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Polycarbonate lens models are only for Class I, Div 2 locations HBP>o<xx models are rated CID1 B, C, D
CID2 PROTOCO Part Number CID1 CIID1 ClID2 Voltage Lens CCT Fixture
Lumens Watt
Standard High Bay with Controls
DALI
Wireless
DALI
Wireless
DALI & Wireless
HBDGCMN-D1
HBDGCMN-Z2
HBDGNMN-D1
HBDGNMN-Z2
•
•
•
•
100-277V AC
100-277V AC
100-277V AC
100-277V AC
Tempered glass
Tempered glass
Tempered glass
Tempered glass
5000K (cool white)
5000K (cool white)
4000K (neutral white)
4000K (neutral white)
17,500
17,500
16,000
16,000
175
175
175
175
100
100
91
91
Wall Controller
WLC-004-MBAL 120-277V AC 10W typical, 20W
max Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%)
For more information, please go to www.dialight.com or http://www.dialight.com/Assets/Brochures And_CatalogsAllumination/High_Bay_Controls_UL844.pdf
www.dialight.com
59
SafeSite Hazardous Application| High Bay
www.dialight.com 59
For more information, please go to www.dialight.com or http://www.dialight.com/Assets/Brochures_And_Catalogs/Illumination/High_Bay_Controls_UL844.pdf
Polycarbonate lens models are only for Class I, Div 2 locationsHBPxxxx models are rated CID1 B, C, D
Classifications: CID1 C, D • CID2 Groups A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
SafeSite® LED High BayOrdering Information and Mounting Accessories
Part Number CID1 CID2 CIID1 CIID2 CIII Voltage Lens Warranty CCTFixture
LumensWatt LPW
Standard Models - 100 - 277V AC
HBP9C3M • • 100-277V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBM9C3M • • • • 100-277V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBM8C3G • 100-277V AC Clear Tempered glass 5yr 5000K (cool white) 5,500 146 38
Standard Models - 347 - 480V AC
HBDGCTN • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 17,000 172 99
HBC9CTN • • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 14,500 172 84
HBDGC5N • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 14,000 161 87
HBF2C5N • • • • 347-480V AC Diffused Polycarbonate 5yr 5000K (cool white) 12,000 161 75
HBD2C5N • • • 347-480V AC Clear Polycarbonate 5yr 5000K (cool white) 12,000 161 75
HBC9C6N • • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 11,000 161 68
HBF2C5M • • • • 347-480V AC Diffused Polycarbonate 5yr 5000K (cool white) 10,500 146 72
HBD2C5M • • • 347-480V AC Clear Polycarbonate 5yr 5000K (cool white) 10,500 146 72
HBP9C6M • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBM9C6M • • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBC9C6M • • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 9,500 146 65
HBF3C5L • • • • 347-480V AC Diffused Polycarbonate 5yr 5000K (cool white) 8,500 124 69
HBD3C5L • • • 347-480V AC Diffused Glass 5yr 5000K (cool white) 8,500 124 69
HBC8C6G • • • • 347-480V AC Clear Tempered glass 5yr 5000K (cool white) 5,500 146 38
Part Number CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixture
LumensWatt LPW PROTOCOL
Standard High Bay with Controls
HBDGCMN-D1 • 100-277V AC Tempered glass 5000K (cool white) 17,500 175 100 DALI
HBDGCMN-Z2 • 100-277V AC Tempered glass 5000K (cool white) 17,500 175 100 Wireless
HBDGNMN-D1 • 100-277V AC Tempered glass 4000K (neutral white) 16,000 175 91 DALI
HBDGNMN-Z2 • 100-277V AC Tempered glass 4000K (neutral white) 16,000 175 91 Wireless
Wall Controller
WLC-004-MBAL 120-277V AC10W typical, 20W
maxDALI &
Wireless
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%)
I SafeSite Hazardous Application I High Bay
SafeSite® LED High Bay Ordering Information and Mounting Accessories
Suitable for: CID1 • CID2 HBXW1 • Wall mount
Suitable for: CID2 HBXW2 • Swivel bracket and cable gland
Suitable for: CID2
HBXCG • Cable gland
Suitable for: CID2
HBX-DUAL-BRCKT • Dual bracket
Suitable for: CID1 • CID2
HBXC1 • Ceiling mount
Suitable for: CID1 • CID2
HBXW3-SSL-316 • Stainless steel swivel bracket • 316 Stainless steel
HBXW3-SSL-304 • Stainless steel swivel bracket • 304 Stainless steel
60 www.dialight.com
SafeSite Hazardous Application| High Bay
60 www.dialight.com
HBXW2• Swivel bracket and cable gland
HBXC1• Ceiling mount
HBXW1• Wall mount
HBX-DUAL-BRCKT• Dual bracket
HBXW3-SSL-316• Stainless steel swivel bracket• 316 Stainless steel
HBXW3-SSL-304• Stainless steel swivel bracket• 304 Stainless steel
HBXCG• Cable gland
Suitable for: CID1 • CID2 Suitable for: CID2
Suitable for: CID2 Suitable for: CID2
Suitable for: CID1 • CID2 Suitable for: CID1 • CID2
SafeSite® LED High BayOrdering Information and Mounting Accessories
SafeSite Hazardous Application I Floodlight
• CID2 A,B,C,D
• CIID1 E,F,G
• ClID2 F,G
• CIII
• UL 844
• UL 1598/A
• CSA 22.2 NO. 137
• IP66/67
• 1K07
• 10yr full performance warranty
• L70 rated for >100,000 hours
Dialight Floodlight
Metal Halide
High Pressure Sodium
Comparison Warranty L70
10yr >100,000 1 6,000
1 20,000
Im/W Lumens Wattage
13 5 [3+131 _
El4.1
133 13+131
47.2 140
NEMA 5 Field angle = 93°
NEMA 2 Field angle = 23°
NEMA 4 Field angle = 52°
NEMA 6 Field angle = 115°
NEMA 6x7 Field angle= 15°x 140°
NEMA 7x6 Field angle=140° x 115°
61 www.dialight.com
SafeSite® LED Floodlight for Hazardous applications
"- -hanical information
Fixture weight: 30 lbs
Shipping weight: 34 lbs
304 Stainless steel trunnion mounting bracket included
0.55 sq. ft.
(2) 3/4" NPT cable entries
Ratings and Certifications
"Al features not available on every model. Please refer to product part number pages for model specifics.
Temperature Ratings Ambient Temperature Range T4 Temperature Code Ambient Temperature Range T5 Temperature Code
15,000 - 13,5001m models 11,000 - 10,7501m models
-40F to +149F (-40C to +65C) -40F to +149F (-40C to +65C)
Specifications
Voltage options:
100 - 277V AC Die Cast Copper free aluminum Housing: Copper free aluminum
347 - 487V AC Sand Cast Copper free aluminum Lens options: Tempered glass
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20%
Surge protection: IEC 61000-4-5 6kV line-to-line , 6kV line-to-ground
Mounting:
EPA (Sq. fl)
Entry:
T-Rating 15,000 130 115 T5 14,750 130 113 T2 13,500 140 96
T2A 11,500 109 105 11,250 109 103 11,000 109 101
10,750 109 99 10,500 109 96
Mounting Heights
30'
1
15
Dimensions
la 6 3 0
As Dimension are in Inches [mm]
Light Distribution Patterns
259
SafeSite Hazardous Application| Floodlight
www.dialight.com 61
Temperature RatingsAmbient Temperature Range T4 Temperature Code Ambient Temperature Range T5 Temperature Code
15,000 - 13,500lm models 11,000 - 10,750lm models
-40F to +149F (-40C to +65C) -40F to +149F (-40C to +65C)
Ratings and Certifications
• UL 844 • CID2 A,B,C,D • IK07
• UL 1598/A • CIID1 E,F,G • 10yr full performance warranty
• CSA 22.2 NO. 137 • CIID2 F,G • L70 rated for >100,000 hours
• IP66/67 • CIII
Mechanical information
Fixture weight: 30 lbs
Shipping weight: 34 lbs
Mounting:304 Stainless steel trunnion mounting bracket included
EPA (Sq. ft) 0.55 sq. ft.
Entry:(2) 3/4” NPT cable entries
Specifications
Voltage options:
100 - 277V AC Die Cast Copper free aluminum Housing: Copper free aluminum
347 - 487V AC Sand Cast Copper free aluminum Lens options: Tempered glass
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20%
Surge protection: IEC 61000-4-56kV line-to-line , 6kV line-to-ground
Lumens Wattage lm/W Mounting Heights
15,000 130 115 30’
14,750 130 113
13,500 140 96
11,500 109 105
11,250 109 103
11,000 109 101
10,750 109 99
10,500 109 96 15
Dimensions
Dimension are in Inches [mm]
ComparisonWarranty L70 T-Rating
Dialight Floodlight 10yr >100,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
*All features not available on every model. Please refer to product part number pages for model specifics.
Light Distribution Patterns
NEMA 7x6Field angle=140o x 115o
NEMA 6x7Field angle= 15o x 140o
NEMA 6Field angle = 115o
NEMA 5Field angle = 93o
NEMA 4Field angle = 52o
NEMA 2Field angle = 23o
SafeSite® LED Floodlightfor Hazardous applications
1131
130 115 130 113 130 113
140 104 140 104 140 96
109 105
109 105 109 103 109 101
109 96 109 99
113 104
113 100 112 89 112 89
112 89
Light Distribution Pattern
Very wide (115°) Asymmetrical (140° x 115°) Asymmetrical (115°x 140°)
Wide (93°) Medium (52°)
Narrow (23°) Asymmetrical (140° x 115°)
Asymmetrical (115°x 140°) Very wide (115°)
Wide (93°) Medium (52°) Narrow (23°)
Asymmetrical (140° x 115°)
Very wide (115°)
Wide (93°) Medium (52°)
Narrow (23°)
FLX-2RSR-20DB • Round square round
bracket for 2 lights, 2-3/8" mount, 21" spacing
FLX-3RSR-20DB • Round square round
bracket for 3 lights, 2-3/8" mount, 21" spacing
FLX-4RSR-20DB • Round square round
bracket for 4 lights, 2-3/8" mount, 21" spacing
SafeSite Hazardous Application I Floodlight
SafeSite® LED Floodlight Ordering Information and Mounting Accessories Classifications: CID2 A, B, C, D ClID1 E, F, G ClID2 F, G • CIII
Part Number CID1 CID2 CIID1 ClID2 Voltage Lens CCT 11- 0
Standard Models - 100 - 277V AC FLD466NC4NG • • • 100-277V AC Tempered glass 5000K (cool white) 15,000 FLD476NC4NG • • • 100-277V AC Tempered glass 5000K (cool white) 14,750 FLD467NC4NG • • • 100-277V AC Tempered glass 5000K (cool white) 14,750
FLD455NC4NG • • • 100-277V AC Tempered glass 5000K (cool white) 14,500 FLD444NC4NG • • • 100-277V AC Tempered glass 5000K (cool white) 14,500 FLD422NC4NG • • • 100-277V AC Tempered glass 5000K (cool white) 13,500 FLD276NC2NG • • • 100-277V AC Tempered glass 5000K (cool white) 11,500 FLD267NC2NG • • • 100-277V AC Tempered glass 5000K (cool white) 11,500 FLD266NC2NG • • • 100-277V AC Tempered glass 5000K (cool white) 11,250 FLD255NC2NG • • • 100-277V AC Tempered glass 5000K (cool white) 11,000 FLD244NC2NG • • • 100-277V AC Tempered glass 5000K (cool white) 10,500 FLD222NC2NG • • • 100-277V AC Tempered glass 5000K (cool white) 10,750
Standard Models - 347 - 480V AC FLD276NC5NG • • • 347-480V AC Tempered glass 5000K (cool white) 11,750
FLD266NC5NG • • • 347-480V AC Tempered glass 5000K (cool white) 11,250 FLD255NC5NG • • • 347-480V AC Tempered glass 5000K (cool white) 10,000 FLD244NC5NG • • • 347-480V AC Tempered glass 5000K (cool white) 10,000 FLD222NC5NG • • • 347-480V AC Tempered glass 5000K (cool white) 10,000
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Part numbers listed in the table above are powder coated gray. For bronze powder, coat replace the 10th character with Z FLD244NC2NG becomes FLD244NC2ZG
FLX-3RPA-20DB • Reducer for 3" OD round
pole top to 2-3/8" light
mount
FLX-4RPA-20DB • Reducer for 4" OD round
pole top to 2-3/8" light mount
FLX-1TPT-20DB • Tenon pole topper,
2-3/8" mount
FLX-2LBH-20DB • Bull horn for 2 lights,
2-3/8" mount, 21" spacing
HZXCBL2 • Safety cable Kit
FLX-1RAB-20DB • Tenon pole topper,
2-3/8" mount
FLX-3LBH-20DB • Bull horn for 3 lights,
2-3/8" mount, 21" spacing
FLX-4RBH-20DB • Bull horn for 4 lights
in star configuration, 2-3/8" mount, 21" spacing
FLX-4SPA-20DB • Internal tenon adapter for 4"
square pole top to 2-3/8" light mount
FLX-5SPA-20D3 • 5" square pole top to 2-3/8"
light mount
FLX-6SPA-20D3 • 6" square pole top to 2-3/8"
light mount
FLX-4LBH-20DB • Bull horn for 4 lights,
2-3/8" mount, 21" spacing
62
www.dialight.com
SafeSite Hazardous Application| Floodlight
62 www.dialight.com
Part numbers listed in the table above are powder coated gray. For bronze powder, coat replace the 10th character with Z. FLD244NC2NG becomes FLD244NC2ZG
Classifications: CID2 A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
SafeSite® LED FloodlightOrdering Information and Mounting Accessories
Part Number CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixture
LumensWatt LPW Light Distribution Pattern
Standard Models - 100 - 277V ACFLD466NC4NG • • • • 100-277V AC Tempered glass 5000K (cool white) 15,000 130 115 Very wide (115°)FLD 476NC4NG • • • • 100-277V AC Tempered glass 5000K (cool white) 14,750 130 113 Asymmetrical (140o x 115o)FLD467NC4NG • • • • 100-277V AC Tempered glass 5000K (cool white) 14,750 130 113 Asymmetrical (115o x 140o)FLD455NC4NG • • • • 100-277V AC Tempered glass 5000K (cool white) 14,500 140 104 Wide (93°)FLD444NC4NG • • • • 100-277V AC Tempered glass 5000K (cool white) 14,500 140 104 Medium (52°)FLD422NC4NG • • • • 100-277V AC Tempered glass 5000K (cool white) 13,500 140 96 Narrow (23°)FLD 276NC2NG • • • • 100-277V AC Tempered glass 5000K (cool white) 11,500 109 105 Asymmetrical (140o x 115o)FLD267NC2NG • • • • 100-277V AC Tempered glass 5000K (cool white) 11,500 109 105 Asymmetrical (115o x 140o)FLD266NC2NG • • • • 100-277V AC Tempered glass 5000K (cool white) 11,250 109 103 Very wide (115°)FLD255NC2NG • • • • 100-277V AC Tempered glass 5000K (cool white) 11,000 109 101 Wide (93°)FLD244NC2NG • • • • 100-277V AC Tempered glass 5000K (cool white) 10,500 109 96 Medium (52°)FLD222NC2NG • • • • 100-277V AC Tempered glass 5000K (cool white) 10,750 109 99 Narrow (23°)
Standard Models - 347 - 480V ACFLD 276NC5NG • • • • 347-480V AC Tempered glass 5000K (cool white) 11,750 113 104 Asymmetrical (140o x 115o)FLD266NC5NG • • • • 347-480V AC Tempered glass 5000K (cool white) 11,250 113 100 Very wide (115°)FLD255NC5NG • • • • 347-480V AC Tempered glass 5000K (cool white) 10,000 112 89 Wide (93°)FLD244NC5NG • • • • 347-480V AC Tempered glass 5000K (cool white) 10,000 112 89 Medium (52°)FLD222NC5NG • • • • 347-480V AC Tempered glass 5000K (cool white) 10,000 112 89 Narrow (23°)
FLX-3RPA-20DB• Reducer for 3” OD round
pole top to 2-3/8” light mount
FLX-4RPA-20DB• Reducer for 4” OD round
pole top to 2-3/8” light mount
FLX-1TPT-20DB• Tenon pole topper,
2-3/8” mount
FLX-2LBH-20DB• Bull horn for 2 lights,
2-3/8” mount, 21” spacing
HZXCBL2• Safety cable Kit
FLX-4SPA-20DB• Internal tenon adapter for 4”
square pole top to 2-3/8” light mount
FLX-5SPA-20DB• 5” square pole top to 2-3/8”
light mount
FLX-6SPA-20DB• 6” square pole top to 2-3/8”
light mountFLX-1RAB-20DB• Tenon pole topper,
2-3/8” mount FLX-2RSR-20DB• Round square round
bracket for 2 lights, 2-3/8” mount, 21” spacing
FLX-3LBH-20DB• Bull horn for 3 lights,
2-3/8” mount, 21” spacing
FLX-4RSR-20DB• Round square round
bracket for 4 lights, 2-3/8” mount, 21” spacing
FLX-3RSR-20DB• Round square round
bracket for 3 lights, 2-3/8” mount, 21” spacing
FLX-4LBH-20DB• Bull horn for 4 lights,
2-3/8” mount, 21” spacing
FLX-4RBH-20DB• Bull horn for 4 lights
in star configuration, 2-3/8” mount, 21” spacing
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Dialight Linear
Metal Halide
High Pressure Sodium
Fluorescent
Comparison Warranty
L70
5yr >125,000 1 6,000 1 20,000 1 24,000
- 15.7$1.403.41 -
- 14.n1343..111
27.06
1517,5,1
SLIM 1769
46.31 (11227.111 11914 _0.17
Light Distribution Pattern
SafeSite Hazardous Application I Linear
SafeSite® LED End-to-End Linear Fixture for Hazardous applications
• UL 1598/A • CSA 22.2 No. 250.0 • UL844 • CSA 22.2 No. 137
• 5yr full performance warranty • L70 rated for >125,000 hours
Ratings and Certifications
• IP66/67 • NEMA 4X • CID2 A,B,C,D • CIID1 E,F,G • ClID2 F,G
• CIII "AI features not available on every model. Please refer to product part number pages for model specifics.
Mechanical information
Fixture weight: 4' linear: 18 lbs (8.16 kg) 2' linear: 13 lbs (5.90 kg)
Shipping weight:
Temperature Ratings
Ambient Temperature Range Ambient Temperature Range T4A Temperature Code T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)
Specifications 4' linear: 20 lbs (9.07 kg) Voltage options: 120 - 277V AC Housing: Extruded 6063 aluminum 2' linear: 15 lbs (6.80 kg) Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Polycarbonate
Mounting: (4) 3/4" NPT openings Power factor: >0.9 CRI: 80
Optional ceiling, flush or swivel THD: <20% CCT: 5000K (cool white) mounting bracket Surge protection: 6 kV line to line, 6 kV line to ground 4000K (neutral white)
Lumens Wattage Im/W Mounting Heights T-Rating 7,500 60 125 20'
T5 6,750 60 113 T2 4,000 32 125
T2A 3,500 32 109 10' T3
Dimensions
1
r
2' Models 4' Models Dimension are in Inches [mm]
Circular Pattern
www.dialight.com 63
SafeSite Hazardous Application| Linear
www.dialight.com 63
Temperature Ratings
Ambient Temperature Range T4A Temperature Code
Ambient Temperature Range T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)
Dimensions
Light Distribution Pattern
Circular Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,500 60 125 20’
6,750 60 113
4,000 32 125
3,500 32 109 10’
Ratings and Certifications
• UL 1598/A • IP66/67
• CSA 22.2 No. 250.0 • NEMA 4X
• UL844 • CID2 A,B,C,D
• CSA 22.2 No. 137 • CIID1 E,F,G
• 5yr full performance warranty • CIID2 F,G
• L70 rated for >125,000 hours • CIII
Mechanical information
Fixture weight:4’ linear: 18 lbs (8.16 kg)
2’ linear: 13 lbs (5.90 kg)
Shipping weight:
4’ linear: 20 lbs (9.07 kg)
2’ linear: 15 lbs (6.80 kg)
Mounting: (4) 3/4” NPT openings
Optional ceiling, flush or swivel mounting bracket
ComparisonWarranty L70 T-Rating
Dialight Linear 5yr >125,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Fluorescent 1 24,000 T3
Specifications
Voltage options: 120 - 277V AC Housing: Extruded 6063 aluminum
Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Polycarbonate
Power factor: >0.9 CRI: 80
THD: <20% CCT: 5000K (cool white)
Surge protection: 6 kV line to line, 6 kV line to ground 4000K (neutral white)
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED End-to-End Linear Fixturefor Hazardous applications
2' Models 4' Models
Part Number
LBD2MB3FNNNNGN 4'
LBD6MB3FNNNNGN 4'
LAD2MB3BNNNNGN 2'
LAD6MB3BNNNNGN 2'
LBF2MB3FNNNNGN
4'
LBF6MB3FNNNNGN
4'
LAF2MB3BNNNNGN
2'
LAF6MB3BNNNNGN
2'
ig Distribution
Circular
Circular
Circular
Circular
Circular
Circular
Circular
Circular
SafeSite
Hazardous Application I Linear
SafeSite® LED End-to-End Linear Fixture Ordering Information and Mounting Accessories Classifications: CID2 A, B, C, D CIID1 E, F, G CIID2 F, G • CIII
CID1 CID2 CHOI CIID2 ■
Voltage Lens CCT Fixture Lumens
LPW ■ CID2 Models
80 • 120 - 277V AC Clear 5000K (cool white) 7,500 60 125
80 • 120 - 277V AC Diffused 5000K (cool white) 6,750 60 113
80 • 120 - 277V AC Clear 5000K (cool white) 4,000 32 125
80 • 120 - 277V AC Diffused 5000K (cool white) 3,500 32 109
ClID1 Models
80 • 120 - 277V AC Clear 5000K (cool white) 7,500 60 125
80 • • 120 - 277V AC Diffused 5000K (cool white) 6,750 60 113
80 • 120 - 277V AC Clear 5000K (cool white) 4,000 32 125
80 • • • 120 - 277V AC Diffused 5000K (cool white) 3,500 32 109 All values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Part numbers listed in the above table are cool white. For neutral white models replace the 6th character with N. Ex. LBD2MB3FNNNNGN becomes LBD2MN3FNNNNGN.
Swivel Mount
EEX-S6 • 316 Stainless steel swivel mounting
bracket • Can be angled at 0°, 30°, 45°, 60°,
and 90°
Ceiling Mount
EEX-C6 • 316 Stainless steel fixed ceiling mount
Flush Mount
EEX-F6 • 316 Stainless steel flush mount
._-041111.
6111114
64 www.dialight.com
SafeSite Hazardous Application| Linear
64 www.dialight.com
Part numbers listed in the above table are cool white. For neutral white models replace the 6th character with N. Ex. LBD2MB3FNNNNGN becomes LBD2MN3FNNNNGN.
Part Number 1 Length CRI CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixture
LumensWatt LPW
Light Distribution
PatternCID2 Models
LBD2MB3FNNNNGN 4' 80 • 120 - 277V AC Clear 5000K (cool white) 7,500 60 125 Circular
LBD6MB3FNNNNGN 4' 80 • 120 - 277V AC Diffused 5000K (cool white) 6,750 60 113 Circular
LAD2MB3BNNNNGN 2' 80 • 120 - 277V AC Clear 5000K (cool white) 4,000 32 125 Circular
LAD6MB3BNNNNGN 2' 80 • 120 - 277V AC Diffused 5000K (cool white) 3,500 32 109 Circular
CIID1 Models
LBF2MB3FNNNNGN 4' 80 • • • 120 - 277V AC Clear 5000K (cool white) 7,500 60 125 Circular
LBF6MB3FNNNNGN 4' 80 • • • 120 - 277V AC Diffused 5000K (cool white) 6,750 60 113 Circular
LAF2MB3BNNNNGN 2' 80 • • • 120 - 277V AC Clear 5000K (cool white) 4,000 32 125 Circular
LAF6MB3BNNNNGN 2' 80 • • • 120 - 277V AC Diffused 5000K (cool white) 3,500 32 109 Circular
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Classifications: CID2 A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
SafeSite® LED End-to-End Linear FixtureOrdering Information and Mounting Accessories
EEX-S6• 316 Stainless steel swivel mounting
bracket• Can be angled at 0°, 30°, 45°, 60°,
and 90°
EEX-C6• 316 Stainless steel fixed ceiling mount
Ceiling Mount
Flush Mount
EEX-F6• 316 Stainless steel flush mount
Swivel Mount
SafeSite Hazardous Application I Linear
SafeSite® LED Linear - Low Profile - Class I Div. 2 / Class II for Hazardous applications
Ratings and Certifications
• UL 1598/A • CSA C22.2 No.137 • UL 8750 • CID2 A,B,C,D
• IP66/67 • CIID1 E,F,G • NEMA 4X • ClID2 F,G
• 5yr full performance warranty • CIII • L70 rated for >100,000 hours
"AI features not available on every model. Please refer to product part number pages for model specifics.
Mechanical information Temperature Ratings
Fixture weight: Ambient Temperature Range Ambient Temperature Range
4' linear: 10 lbs (4.50 kg) T4A Temperature Code T5 Temperature Code
2' linear: 7 lbs (3.13 kg) -40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)
Shipping weight: Specifications 4' linear: 11 lbs (4.90 kg Voltage options: 100 - 277V AC Housing: Copper free aluminum 2' linear: 8 lbs (3.64 kg) Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Polycarbonate
Mounting: (4) 3/4" NPT openings Power factor: >0.9 CRI: 75 / 80
Optional swivel bracket - THD: <20% CCT: 5000K (cool white) LPXW4 Surge protection: 4 kV line to line, 4 kV line to ground 4000K (neutral white) Optional low profile bracket - LPXW4LP
Comparison Warranty L70
Dialight Linear 5yr >100,000 Metal Halide 1 6,000
High Pressure Sodium 1 20,000
Fluorescent 1 24,000
Dimensions
47.8) 11214.41
Fbdure
Lumens Wattage Im/W Mounting Heights T-Rating 7,250 66 110 20'
T5 6,700 66 102 T2 3,600 33 109
T2A 3,300 33 100 10' T3
3.06 - 23.61 1 [77.8] [604.81
4M) 1 '9 [120.651 Z Fbchse
Dimension are in Inches [mm]
Light Distribution Pattern
Circular Pattern
www.dialight.com 65
SafeSite Hazardous Application| Linear
www.dialight.com 65
Temperature Ratings
Ambient Temperature Range T4A Temperature Code
Ambient Temperature Range T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)
Dimensions
Light Distribution Pattern
Circular Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,250 66 110 20’
6,700 66 102
3,600 33 109
3,300 33 100 10’
Ratings and Certifications
• UL 1598/A • CSA C22.2 No.137
• UL 8750 • CID2 A,B,C,D
• IP66/67 • CIID1 E,F,G
• NEMA 4X • CIID2 F,G
• 5yr full performance warranty • CIII
• L70 rated for >100,000 hours
Mechanical information
Fixture weight:4’ linear: 10 lbs (4.50 kg)
2’ linear: 7 lbs (3.13 kg)
Shipping weight:
4’ linear: 11 lbs (4.90 kg
2’ linear: 8 lbs (3.64 kg)
Mounting: (4) 3/4” NPT openings
Optional swivel bracket - LPXW4Optional low profile bracket - LPXW4LP
ComparisonWarranty L70 T-Rating
Dialight Linear 5yr >100,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Fluorescent 1 24,000 T3
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Polycarbonate
Power factor: >0.9 CRI: 75 / 80
THD: <20% CCT: 5000K (cool white)
Surge protection: 4 kV line to line, 4 kV line to ground 4000K (neutral white)
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED Linear - Low Profile - Class I Div. 2 / Class IIfor Hazardous applications
SafeSite
Hazardous Application I Linear
SafeSite® LED Linear - Low Profile - Class I Div. 2 / Class II Ordering Information and Mounting Accessorie
Length CID1 CID2 CIID1 CIID2 CIII Fixture
Lumens Watt LPW Part Number, Voltage Lens CCT
Class I, D. 2 Models
LPD3C4M2P 4' 75 • 100 - 277V AC Clear 5000K (cool white) 7,250 66 110
LPD3C4H2W 4' 75 • 100 - 277V AC Textured 5000K (cool white) 6,700 66 102
LPD3B4M2P 4' 80 • 100 - 277V AC Diffused 5000K (cool white) 6,500 66 98
LPD3B4H2W 4' 80 • 100 - 277V AC Clear 5000K (cool white) 6,000 66 91
LPD3C4D2P 2' 75 • 100 - 277V AC Textured 5000K (cool white) 3,600 33 109
LPD3C4B2W 2' 75 • 100 - 277V AC Diffused 5000K (cool white) 3,300 33 100
LPD3B4D2P 2' 80 • 100 - 277V AC Clear 5000K (cool white) 3,200 33 97
LPD3B4B2W 2' 80 • 100 - 277V AC Textured 5000K (cool white) 2,900 33 88
Class II Models
LPF3C4M2P 4' 75 • • • 100 - 277V AC Clear 5000K (cool white) 7,000 66 106
LPF3C4H2W 4' 75 • • • 100 - 277V AC Diffused 5000K (cool white) 6,500 66 98
LPF3B4M2P 4' 80 • • • 100 - 277V AC Clear 5000K (cool white) 6,300 66 95
LPF3B4H2W 4' 80 • • • 100 - 277V AC Diffused 5000K (cool white) 6,000 66 91
LPF3C4D2P 2' 75 • • • 100 - 277V AC Clear 5000K (cool white) 3,500 33 106
LPF3C4B2W 2' 75 • • • 100 - 277V AC Diffused 5000K (cool white) 3,200 33 97
LPF3B4D2P 2' 80 • • • 100 - 277V AC Clear 5000K (cool white) 3,000 33 91
LPF3B4B2W 2' 80 • • • 100 - 277V AC Diffused 5000K (cool white) 2,700 33 82
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Part numbers listed in the table above are cool white. For neutral white model, replace the 5th character with N. Ex. LPD3C4M2P becomes LPD3N4M2P
g Distribution
circular
circular
circular
circular
circular
circular
circular
circular
circular
circular
circular
circular
circular
circular
circular
circular
LPXW4 • Mounting bracket • Can be angled at 0°, 30°,
45°, 60° & 90°
LPXW4LP • Low profile mounting
bracket • Can be angled at 0° and
15°
LTXENDCAPKIT • Chain mount and
secondary retention bracket
LTXSAFEKIT • Safety Cable Kit for
secondary retention
66
www.dialight.com
SafeSite Hazardous Application| Linear
66 www.dialight.com
Part numbers listed in the table above are cool white. For neutral white model, replace the 5th character with N. Ex. LPD3C4M2P becomes LPD3N4M2P
Part Number 1 Length CRI CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixture
LumensWatt LPW
Light Distribution
PatternClass I, Div. 2 Models
LPD3C4M2P 4' 75 • 100 - 277V AC Clear 5000K (cool white) 7,250 66 110 circular
LPD3C4H2W 4' 75 • 100 - 277V AC Textured 5000K (cool white) 6,700 66 102 circular
LPD3B4M2P 4' 80 • 100 - 277V AC Diffused 5000K (cool white) 6,500 66 98 circular
LPD3B4H2W 4' 80 • 100 - 277V AC Clear 5000K (cool white) 6,000 66 91 circular
LPD3C4D2P 2' 75 • 100 - 277V AC Textured 5000K (cool white) 3,600 33 109 circular
LPD3C4B2W 2' 75 • 100 - 277V AC Diffused 5000K (cool white) 3,300 33 100 circular
LPD3B4D2P 2' 80 • 100 - 277V AC Clear 5000K (cool white) 3,200 33 97 circular
LPD3B4B2W 2' 80 • 100 - 277V AC Textured 5000K (cool white) 2,900 33 88 circular
Class II Models
LPF3C4M2P 4' 75 • • • 100 - 277V AC Clear 5000K (cool white) 7,000 66 106 circular
LPF3C4H2W 4' 75 • • • 100 - 277V AC Diffused 5000K (cool white) 6,500 66 98 circular
LPF3B4M2P 4' 80 • • • 100 - 277V AC Clear 5000K (cool white) 6,300 66 95 circular
LPF3B4H2W 4' 80 • • • 100 - 277V AC Diffused 5000K (cool white) 6,000 66 91 circular
LPF3C4D2P 2' 75 • • • 100 - 277V AC Clear 5000K (cool white) 3,500 33 106 circular
LPF3C4B2W 2' 75 • • • 100 - 277V AC Diffused 5000K (cool white) 3,200 33 97 circular
LPF3B4D2P 2' 80 • • • 100 - 277V AC Clear 5000K (cool white) 3,000 33 91 circular
LPF3B4B2W 2' 80 • • • 100 - 277V AC Diffused 5000K (cool white) 2,700 33 82 circular
SafeSite® LED Linear - Low Profile - Class I Div. 2 / Class IIOrdering Information and Mounting Accessories
LTXSAFEKIT• Safety Cable Kit for
secondary retention
LPXW4LP• Low profile mounting
bracket• Can be angled at 0° and
15°
LTXENDCAPKIT• Chain mount and
secondary retention bracket
LPXW4• Mounting bracket• Can be angled at 0°, 30°,
45°, 60° & 90°
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
SafeSite Hazardous Application I Linear
SafeSite® LED Linear - Top Conduit - Class I Div. 2 / Class II for Hazardous applications
Ratings and Certifications
• UL 844 • CID2 A,B,C,D
• UL 1598/A • ClID1 E,F,G
• UL 8750 • ClID2 F,G
• CSA C22.2 No.137 • CIII
• IP66 • 5yr full performance warranty
• NEMA 4X • L70 rated for >100,000 hours
"Al features not available on every model. Please refer to product part number pages for model specifics.
Mechanical information
Fixture weight: 4' linear: 11 lbs (4.99 kg) 2' linear: 10 lbs (4.53 kg)
Shipping weight:
Temperature Ratings
Ambient Temperature Range Ambient Temperature Range T4A Temperature Code T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)
Specifications 4' linear: 13 lbs (5.90 kg) Voltage options: 100 - 277V AC Housing: Copper free aluminum
2' linear: 12 lbs (5.44 kg) Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Polycarbonate
Mounting: (3) 3/4" NPT openings Power factor: >0.9 CRI: 75 / 80 Optional swivel bracket - THD: <20% CCT: 5000K (cool white) LTXW4 Optional low profile bracket -
Surge protection: 4 kV line to line, 4 kV line to ground 4000K (neutral white)
LTXW4LP
Comparison Lumens Wattage Im/W Mounting Heights Warranty L70 T-Rating 7,250 66 110 20'
Dialight Linear 5yr >100,000 6,900 66 105 Metal Halide 1 6,000 T2 3,600 33 109 High Pressure Sodium 1 20,000 T2A 3,300 33 100 10' Fluorescent 1 24,000 T3
Dimensions
•
I 0
117 11119.6)
4.91 11215.41
0.96 La, f 213,211 12111)
Dimension are in Inches [mm]
Light Distribution Pattern
Circular Pattern
www.dialight.com 67
SafeSite Hazardous Application| Linear
www.dialight.com 67
Ratings and Certifications
• UL 844 • CID2 A,B,C,D
• UL 1598/A • CIID1 E,F,G
• UL 8750 • CIID2 F,G
• CSA C22.2 No.137 • CIII
• IP66 • 5yr full performance warranty
• NEMA 4X • L70 rated for >100,000 hours
Temperature Ratings
Ambient Temperature Range T4A Temperature Code
Ambient Temperature Range T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)
Dimensions
Light Distribution Pattern
Circular Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,250 66 110 20’
6,900 66 105
3,600 33 109
3,300 33 100 10’
Mechanical information
Fixture weight:4’ linear: 11 lbs (4.99 kg)
2’ linear: 10 lbs (4.53 kg)
Shipping weight:
4’ linear: 13 lbs (5.90 kg)
2’ linear: 12 lbs (5.44 kg)
Mounting: (3) 3/4” NPT openings
Optional swivel bracket - LTXW4Optional low profile bracket - LTXW4LP
ComparisonWarranty L70 T-Rating
Dialight Linear 5yr >100,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Fluorescent 1 24,000 T3
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
Operating temp: -40°F to +149°F (-40°C to +65°C) Lens: Polycarbonate
Power factor: >0.9 CRI: 75 / 80
THD: <20% CCT: 5000K (cool white)
Surge protection: 4 kV line to line, 4 kV line to ground 4000K (neutral white)
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED Linear - Top Conduit - Class I Div. 2 / Class IIfor Hazardous applications
SafeSite Hazardous Application I Linear
g Distribution Voltage
LTXENDCAPKIT • Chain mount and
secondary retention bracket
LTXW4LP • Low profile mounting
bracket • Can be angled at 0° and
15°
LTXW4 • Mounting bracket • Can be angled at 0°, 30°,
45°, 60° & 90°
LTXSAFEKIT • Safety Cable Kit for
secondary retention
LTXLSXW4 • Retrofit bracket adapter • used to connect LTM
model fixtures to an existing LSXW4 bracket
68 www.dialight.com
SafeSite® LED Linear - Top Conduit - Class I Div. 2 / Class II Ordering Information and Mounting Accessories Classifications: CID2 A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
Part Number' CIII CIID2 CIID1 CID2 CID1 1111
Length
Class I, D. 2 Models
4' 75 • 100 - 277V AC Clear 5000K (cool white) 7,250 66 110 circular
4' 75 • 100 - 277V AC Textured 5000K (cool white) 6,900 66 105 circular
4' 75 • 100 - 277V AC Diffused 5000K (cool white) 6,700 66 102 circular
4' 80 • 100 - 277V AC Clear 5000K (cool white) 6,500 66 98 circular
4' 80 • 100 - 277V AC Textured 5000K (cool white) 6,200 66 94 circular
4' 80 • 100 - 277V AC Diffused 5000K (cool white) 6,000 66 91 circular
2' 75 • 100 - 277V AC Clear 5000K (cool white) 3,600 33 109 circular
2' 75 • 100 - 277V AC Textured 5000K (cool white) 3,400 33 103 circular
2' 75 • 100 - 277V AC Diffused 5000K (cool white) 3,300 33 100 circular
2' 80 • 100 - 277V AC Clear 5000K (cool white) 3,200 33 97 circular
2' 80 • 100 - 277V AC Textured 5000K (cool white) 3,000 33 91 circular
2' 80 • 100 - 277V AC Diffused 5000K (cool white) 2,900 33 88 circular
Class II Models
4' 75 • • • 100 - 277V AC Clear 5000K (cool white) 7,000 66 106 circular
4' 75 • • • 100 - 277V AC Diffused 5000K (cool white) 6,600 66 100 circular
4' 80 • • • 100 - 277V AC Clear 5000K (cool white) 6,300 66 95 circular
4' 80 • • • 100 - 277V AC Diffused 5000K (cool white) 6,000 66 91 circular
2' 75 • • • 100 - 277V AC Clear 5000K (cool white) 3,500 33 106 circular
2' 75 • • • 100 - 277V AC Diffused 5000K (cool white) 3,300 33 100 circular
2' 80 • • • 100 - 277V AC Clear 5000K (cool white) 3,100 33 94 circular
2' 80 • • • 100 - 277V AC Diffused 5000K (cool white) 2,900 33 88 circular
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Part numbers listed in the table above are cool white. For neutral white model, replace the 5th character with N. Ex. LTD3c4D2P becomes LTD3N4D2P
LTD3C4M2P
LTD3C4H2D
LTD3C4H2W
LTD3B4M2P
LTD3B4H2D
LTD3B4 H2W
LTD3C4D2P
LTD3C4B2D
LTD3C4B2W
LTD3B4D2P
LTD3B4B2D
LTD3B4B2W
LTF3C4M2P
LTF3C4H2D
LTF3B4M2P
LTF3B4H2D
LTF3C4D2P
LTF3C4B2D
LTF3B4D2P
LTF3B4B2D
Lens Fixture
Lumens Watt
SafeSite Hazardous Application| Linear
68 www.dialight.com
Part numbers listed in the table above are cool white. For neutral white model, replace the 5th character with N. Ex. LTD3C4D2P becomes LTD3N4D2P
Classifications: CID2 A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
SafeSite® LED Linear - Top Conduit - Class I Div. 2 / Class IIOrdering Information and Mounting Accessories
Part Number 1 Length CRI CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixture
LumensWatt LPW
Light Distribution
PatternClass I, Div. 2 Models
LTD3C4M2P 4' 75 • 100 - 277V AC Clear 5000K (cool white) 7,250 66 110 circular
LTD3C4H2D 4' 75 • 100 - 277V AC Textured 5000K (cool white) 6,900 66 105 circular
LTD3C4H2W 4' 75 • 100 - 277V AC Diffused 5000K (cool white) 6,700 66 102 circular
LTD3B4M2P 4' 80 • 100 - 277V AC Clear 5000K (cool white) 6,500 66 98 circular
LTD3B4H2D 4' 80 • 100 - 277V AC Textured 5000K (cool white) 6,200 66 94 circular
LTD3B4H2W 4' 80 • 100 - 277V AC Diffused 5000K (cool white) 6,000 66 91 circular
LTD3C4D2P 2' 75 • 100 - 277V AC Clear 5000K (cool white) 3,600 33 109 circular
LTD3C4B2D 2' 75 • 100 - 277V AC Textured 5000K (cool white) 3,400 33 103 circular
LTD3C4B2W 2' 75 • 100 - 277V AC Diffused 5000K (cool white) 3,300 33 100 circular
LTD3B4D2P 2' 80 • 100 - 277V AC Clear 5000K (cool white) 3,200 33 97 circular
LTD3B4B2D 2' 80 • 100 - 277V AC Textured 5000K (cool white) 3,000 33 91 circular
LTD3B4B2W 2' 80 • 100 - 277V AC Diffused 5000K (cool white) 2,900 33 88 circular
Class II Models
LTF3C4M2P 4’ 75 • • • 100 - 277V AC Clear 5000K (cool white) 7,000 66 106 circular
LTF3C4H2D 4’ 75 • • • 100 - 277V AC Diffused 5000K (cool white) 6,600 66 100 circular
LTF3B4M2P 4’ 80 • • • 100 - 277V AC Clear 5000K (cool white) 6,300 66 95 circular
LTF3B4H2D 4’ 80 • • • 100 - 277V AC Diffused 5000K (cool white) 6,000 66 91 circular
LTF3C4D2P 2’ 75 • • • 100 - 277V AC Clear 5000K (cool white) 3,500 33 106 circular
LTF3C4B2D 2’ 75 • • • 100 - 277V AC Diffused 5000K (cool white) 3,300 33 100 circular
LTF3B4D2P 2’ 80 • • • 100 - 277V AC Clear 5000K (cool white) 3,100 33 94 circular
LTF3B4B2D 2’ 80 • • • 100 - 277V AC Diffused 5000K (cool white) 2,900 33 88 circular
LTXSAFEKIT• Safety Cable Kit for
secondary retention
LTXW4LP• Low profile mounting
bracket• Can be angled at 0° and
15°
LTXENDCAPKIT• Chain mount and
secondary retention bracket
LTXW4• Mounting bracket• Can be angled at 0°, 30°,
45°, 60° & 90°
LTXLSXW4• Retrofit bracket adapter• used to connect LTM
model fixtures to an existing LSXW4 bracket
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
SafeSite Hazardous Application I Linear
Ratings and Certifications
• CID2 A,B,C,D • CIID1 E,F,G
• ClID2 F,G
• CIII
• 3yr full performance warranty
• UL 844 • UL 924
• CSA C22.2 NO.137
• IP66
• NEMA 4 X
• L70 rated for >125,000 hours "AI features not available on every model. Rease refer to product part number pages for model specifics.
Comparison Warranty
3yr
1
1
1
L70
>125,000
6,000
20,000
24,000
•=•
SafeSite® LED Linear - Battery Backup for Hazardous applications
Temperature Ratings
Ambient Temperature Range Ambient Temperature Range T4A Temperature Code T5 Temperature Code
Mechanical information
-4°F to +149°F (-20°C to +65°C)
Specifications
-4°F to +149°F (-20°C to +65°C)
Fixture weight: 18.0 lbs (8.16 kg) Voltage options: 120 - 277V AC Housing: Copper free aluminum Shipping weight: 21.0 lbs (9.53 kg) Operating temp: -4°F to +149°F (-20°C to +65°C) Lens: Polycarbonate
Mounting: (1) Threaded 3/4" NPT Side
Power factor: THD:
>0.9 <20%
CRI: CCT:
75
5000K (cool white) (2) Threaded 3/4" NPT Ends Surge protection: 1 kV line to line, 2 kV line to ground Battery Life: 4 years
Battery: 3.6V 10Ah Nimh Battery Duration: >3 hours
T-Rating
T5
T2
T2A
T3
Lumens
7,000
Wattage
85
Mounting Heights
20' and under 82 Dialight Linear
Metal Halide
High Pressure Sodium
Fluorescent
Dimensions
47.81 [1214.4]
18.52 8.66 [115+9.1]
p
ia
8.4,0 WA]
Dimension are in Inches [mm]
Light Distribution Pattern
Circular Pattern
www.dialight.com 69
SafeSite Hazardous Application| Linear
www.dialight.com 69
Dimensions
Light Distribution Pattern
Circular Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,000 85 82 20’ and under
Mechanical information
Fixture weight: 18.0 lbs (8.16 kg)
Shipping weight: 21.0 lbs (9.53 kg)
Mounting:(1) Threaded 3/4” NPT Side(2) Threaded 3/4” NPT Ends
ComparisonWarranty L70 T-Rating
Dialight Linear 3yr >125,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Fluorescent 1 24,000 T3
Specifications
Voltage options: 120 - 277V AC Housing: Copper free aluminum
Operating temp: -4°F to +149°F (-20°C to +65°C) Lens: Polycarbonate
Power factor: >0.9 CRI: 75
THD: <20% CCT: 5000K (cool white)
Surge protection: 1 kV line to line, 2 kV line to ground Battery Life: 4 years
Battery: 3.6V 10Ah Nimh Battery Duration: >3 hours
Ratings and Certifications
• UL 844 • CID2 A,B,C,D
• UL 924 • CIID1 E,F,G
• CSA C22.2 NO.137 • CIID2 F,G
• IP66 • CIII
• NEMA 4 X • 3yr full performance warranty
• L70 rated for >125,000 hours
Temperature Ratings
Ambient Temperature Range T4A Temperature Code
Ambient Temperature Range T5 Temperature Code
-4°F to +149°F (-20°C to +65°C) -4°F to +149°F (-20°C to +65°C)
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED Linear - Battery Backupfor Hazardous applications
82
82
circular
circular
82
82
circular
circular
SafeSite Hazardous Application I Linear
SafeSite® LED Linear - Battery Backup Ordering Information and Mounting Accessories
Classifications: CID2 A, B, C, D • CIID1 E, F, G • CIID2 F, G CIII
This fixture is offered in sustained and maintained configurations. Sustained has a single AC input and battery backup mode is entered upon any loss of power. Fixture cannot be turned off without entering battery backup mode.
Maintained has two AC inputs. The fixture can be turned on and off via AC-1 and Fixture only enters battery backup mode when AC-2 is lost or low.
1g t Distribution Part Number' Length CRI Type CID1 CID2 ClID1 ClID2 Voltage Lens CCT
Fixture Lumens
Class I, Div. 2 Models
LSD3C4MEP
LSD3C4MNP
4'
4'
75
75
Sustained
Maintained
100 - 277V AC
100 - 277V AC
Clear
Clear
5000K (cool white)
5000K (cool white)
7,000
7,000
85
85
Class II Models
LSF3C4MEP 4' 75 Sustained • • • 100 - 277V AC Clear 5000K (cool white) 7,000 85
LSF3C4MNP 4' 75 Maintained • • • 100 - 277V AC Clear 5000K (cool white) 7,000 85
LPW
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSF3C4MEP becomes LSF3N4MEP
LSXW4 • Mounting bracket
• Can be angled at 0°, 30°, 45°, 60° & 90°
LSXENDCAPKIT • Chain mount brackets
HZXSAFEKIT • Safety Cable Kit
70
www.dialight.com
SafeSite Hazardous Application| Linear
70 www.dialight.com
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSF3C4MEP becomes LSF3N4MEP
This fixture is offered in sustained and maintained configurations. Sustained has a single AC input and battery backup mode is entered upon any loss of power. Fixture cannot be turned off without entering battery backup mode.
Maintained has two AC inputs. The fixture can be turned on and off via AC-1 and Fixture only enters battery backup mode when AC-2 is lost or low.
Classifications: CID2 A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
SafeSite® LED Linear - Battery BackupOrdering Information and Mounting Accessories
Part Number 1 Length CRI Type CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixture
LumensWatt LPW
Light Distribution
PatternClass I, Div. 2 Models
LSD3C4MEP 4’ 75 Sustained • 100 - 277V AC Clear 5000K (cool white) 7,000 85 82 circular
LSD3C4MNP 4’ 75 Maintained • 100 - 277V AC Clear 5000K (cool white) 7,000 85 82 circular
Class II Models
LSF3C4MEP 4’ 75 Sustained • • • 100 - 277V AC Clear 5000K (cool white) 7,000 85 82 circular
LSF3C4MNP 4’ 75 Maintained • • • 100 - 277V AC Clear 5000K (cool white) 7,000 85 82 circular
LSXENDCAPKIT• Chain mount brackets
HZXSAFEKIT• Safety Cable Kit
LSXW4• Mounting bracket• Can be angled at 0°, 30°,
45°, 60° & 90°
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
SafeSite
Hazardous Application I Linear
SafeSite® LED Linear - Class I Div. 1 for Hazardous applications
Mechanical information
Fixture weight: 4' linear: 26 lbs (12 kg) 2' linear: 18 lbs (8 kg) Shipping weight: 4' linear: 29 lbs (14 kg) 2' linear: 20 lbs (10 kg)
Mounting: (1) Threaded 3/4" NPT Side (2) Threaded 3/4" NPT Ends
Comparison Warranty L70
Dialight Linear
5yr >125,000 Metal Halide
1
6,000
High Pressure Sodium
1
20,000
Fluorescent
1
24,000
Ratings and Certifications
• UL 844
• CID1 C,D • UL 8750
• CSA C22.2 No.137
• IP66
• 5yr full performance warranty
• NEMA 4X
• L70 rated for >125,000 hours
• ABS
"AI features not available on every model. Rease refer to product part number pages for model specifics.
Temperature Ratings
(oft models) Ambient Temperature Range (2ft models) Ambient Temperature Range T4A Temperature Code T5 Temperature Code
-40°F to +149°F (-40°C to +65°C)
Specifications
-40°F to +149°F (-40°C to +65°C)
Voltage options: 100 - 277V AC Housing: Copper free aluminum 347 - 480V AC Lens: Tempered glass
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20%
Surge protection: 4 kV line to line, 4 kV line to ground
Lumens Wattage Im/W Mounting Heights T-Rating
T5
T2
7,250 78 93 20'
T2A
T3 3,600 39 92 10'
Dimensions
pzasffi
IF IFTl.q
Dimension are in Inches [mm]
Light Distribution Pattern
Circular Pattern
www.dialight.com 71
SafeSite Hazardous Application| Linear
www.dialight.com 71
Temperature Ratings
(4ft models) Ambient Temperature Range T4A Temperature Code
(2ft models) Ambient Temperature Range T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +149°F (-40°C to +65°C)
Ratings and Certifications
• UL 844 • CID1 C,D
• UL 8750 • CSA C22.2 No.137
• IP66 • 5yr full performance warranty
• NEMA 4X • L70 rated for >125,000 hours
• ABS
Dimensions
Light Distribution Pattern
Circular Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,250 78 93 20’
3,600 39 92 10’
Mechanical information
Fixture weight:4’ linear: 26 lbs (12 kg)
2’ linear: 18 lbs (8 kg)
Shipping weight:4’ linear: 29 lbs (14 kg)
2’ linear: 20 lbs (10 kg)
Mounting: (1) Threaded 3/4” NPT Side
(2) Threaded 3/4” NPT Ends
ComparisonWarranty L70 T-Rating
Dialight Linear 5yr >125,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Fluorescent 1 24,000 T3
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
347 - 480V AC Lens: Tempered glass
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20%
Surge protection: 4 kV line to line, 4 kV line to ground
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED Linear - Class I Div. 1for Hazardous applications
SafeSite
Hazardous Application I Linear
SafeSite® LED Linear - Class I Div. 1 Ordering Information and Mounting Accessories Classifications: CID1 C, D
Part Number, CRI CID1 CID2 CIID1 ClID2 1111
Voltage Lens CCT Fixture
Lumens Watt LPW
100 - 277V AC Models
75
75
•
•
100 - 277V AC Tempered glass
100 - 277V AC Tempered glass
5000K (cool white)
5000K (cool white)
7,250
3,600
78
39
93
92
347 - 480V AC Models
75
75
• •
347 - 480V AC Tempered glass
347 - 480V AC Tempered glass
5000K (cool white)
5000K (cool white)
7,250
3,600
78
39
93
92
LSC3C4M3GEX 4'
LSC3C4D3GEX 2'
LSC3C5M3GEX 4'
LSC3C5D3GEX 2'
Light Distributio
circular
circular
circular
circular
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Part numbers listed in the table above are cool white. For neutral white, model replace the 5th character with N. Ex. LSC3C4D3GEX becomes LSC3N4D3GEX
LSXW5 • Mounting bracket
• Can be angled at 0°, 30°, 45°, 60° & 90
HZXSAFEKIT • Safety Cable Kit
72 www.dialight.com
SafeSite Hazardous Application| Linear
72 www.dialight.com
Part numbers listed in the table above are cool white. For neutral white, model replace the 5th character with N. Ex. LSC3C4D3GEX becomes LSC3N4D3GEX
Classifications: CID1 C, D
SafeSite® LED Linear - Class I Div. 1Ordering Information and Mounting Accessories
Part Number 1 Length CRI CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixture
LumensWatt LPW
Light Distribution
100 - 277V AC Models
LSC3C4M3GEX 4’ 75 • 100 - 277V AC Tempered glass 5000K (cool white) 7,250 78 93 circular
LSC3C4D3GEX 2’ 75 • 100 - 277V AC Tempered glass 5000K (cool white) 3,600 39 92 circular
347 - 480V AC Models
LSC3C5M3GEX 4’ 75 • 347 - 480V AC Tempered glass 5000K (cool white) 7,250 78 93 circular
LSC3C5D3GEX 2’ 75 • 347 - 480V AC Tempered glass 5000K (cool white) 3,600 39 92 circular
HZXSAFEKIT• Safety Cable Kit
LSXW5• Mounting bracket• Can be angled at 0°, 30°,
45°, 60° & 90
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
SafeSite Hazardous Application I Linear
information
bs (14.5 kg) bs (15.9 kg)
Threaded 3/4" NPT Side Threaded 3/4" NPT Ends
Mechanical
Fixture weight: 32 I Shipping weight: 35 I Mounting: (1)
(2)
• UL 1598/A • UL 844
• IP66 • NEMA 4X
• CSA 22.2 No. 137
Ratings and Certifications
• CSA 22.2 No. 250 • CID1 C, D
• CID2 A, B, C, D
• 3yr full performance warranty
• L70 rated for >125,000 hours
Lumens
7,250
Wattage
85
Im/W Mounting Heights
85 20'
47.46 [1205.4]
1.1
6.96 [176.8]
SafeSite® LED Linear - Battery Backup - Class I, Div. 1 for Hazardous applications
"Al features not available on every model. Rease refer to product part number pages for model specifics.
Temperature Ratings
(oft models) Ambient Temperature Range T4A Temperature Code
-4°F to +149°F (-20°C to +65°C)
Specifications
Voltage options: 120 - 277V AC Battery duration*: >3 hours
Operating temp: -4°F to +149°F (-20°C to +65°C) Housing: Copper free aluminum Power factor: >0.9 Lens: Tempered glass THD: <20% CRI: 75
Surge protection: 1 kV line to line, 2 kV line to ground CCT: 5000K (cool white)
Battery: 3.6V 10Ah NiMH Expected battery life*:
3 years
Comparison
"© 25°C ambient
Warranty L70 T-Rating
Dialight Linear 5yr >125,000 T4A
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Fluorescent 1 24,000 T3
Dimensions
6.13 155.8:
Dimension are in Inches [mm]
Light Distribution Pattern
Circular Pattern
www.dialight.com 73
SafeSite Hazardous Application| Linear
www.dialight.com 73
Temperature Ratings
(4ft models) Ambient Temperature Range T4A Temperature Code
-4°F to +149°F (-20°C to +65°C)
Ratings and Certifications
• UL 1598/A • CSA 22.2 No. 250
• UL 844 • CID1 C, D
• IP66 • CID2 A, B, C, D
• NEMA 4X • 3yr full performance warranty
• CSA 22.2 No. 137 • L70 rated for >125,000 hours
Dimensions
Light Distribution Pattern
Circular Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
7,250 85 85 20’
Mechanical information
Fixture weight: 32 lbs (14.5 kg)Shipping weight: 35 lbs (15.9 kg)Mounting: (1) Threaded 3/4” NPT Side
(2) Threaded 3/4” NPT Ends
ComparisonWarranty L70 T-Rating
Dialight Linear 5yr >125,000 T4A
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Fluorescent 1 24,000 T3
Specifications
Voltage options: 120 - 277V ACBattery duration*:
>3 hours
Operating temp: -4°F to +149°F (-20°C to +65°C) Housing: Copper free aluminum
Power factor: >0.9 Lens: Tempered glass
THD: <20% CRI: 75
Surge protection: 1 kV line to line, 2 kV line to ground CCT: 5000K (cool white)
Battery: 3.6V 10Ah NiMHExpected battery life*:
3 years
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED Linear - Battery Backup - Class I, Div. 1for Hazardous applications
* @ 25°C ambient
SafeSite
Hazardous Application I Area Light
SafeSite® LED Linear - Battery Backup - Class I, Div. 1 Ordering Information and Mounting Accessories Classifications: CID1 C, D
This fixture is offered in an sustained configuration. Sustained has a single AC input and battery backup mode is entered upon any loss of power. Fixture cannot be turned off without entering battery backup mode.
CID1 CID2 ClID1 CIID2 Voltage Fixture Lumens
ig t Distribution
Class I, Div. 1 Model
LSC3C4MEGEX 4' 75 Sustained •
120 - 277V AC Clear 5000K (cool white) 7,250 85 85 circular
All values typical unless otherwise staled, Lumen values are typical (tolerance +/- 10%).
LSXW5 • Mounting bracket • Can be angled at 0°, 30°,
45°, 60° & 90
HZXSAFEKIT • Safety Cable Kit
74 www.dialight.com
SafeSite Hazardous Application| Area Light
74 www.dialight.com
HZXSAFEKIT• Safety Cable Kit
LSXW5• Mounting bracket• Can be angled at 0°, 30°,
45°, 60° & 90
This fixture is offered in an sustained configuration. Sustained has a single AC input and battery backup mode is entered upon any loss of power. Fixture cannot be turned off without entering battery backup mode.
Classifications: CID1 C, D
Part Number 1 Length CRI Type CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixtureLumens
Watt LPWLight
Distribution Pattern
Class I, Div. 1 Model
LSC3C4MEGEX 4’ 75 Sustained • 120 - 277V AC Clear 5000K (cool white) 7,250 85 85 circular
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
SafeSite® LED Linear - Battery Backup - Class I, Div. 1Ordering Information and Mounting Accessories
IC ea pita
/Mt 15.1.9
for 2'. wr
45° Stanchion Mount Models
11.67 [29.6.3
0
•J 111.6D - 1219.V
Dimensions
Wall Mount Models
Housing:
Lens:
HZD
HZF
HZC
CRI:
CCT:
Copper free aluminum
Poycarbonate or Glass
Poly with Antistatic Coat
Tempered glass
75
5000K (cool white)
4000K (neutral white)
Light Distribution Patterns
360° Light Distribution Pattern
180° Light Distribution Pattern
Wide Throw
75
SafeSite
Hazardous Application I Area Light
SafeSite® LED Area Light for Hazardous applications
Standard Models
Wall Mount Models
45° Stanchion Mount Models
45° Wall Mount Models
Mechanical information
Fixture weight:
Standard:
Wall mount:
450 Wall mount:
450 Stanchion mount:
Shipping weight:
Standard:
Wall mount:
450 Wall mount:
450 Stanchion mount:
Mounting:
Cabling:
Lumens Wattage Im/W
Mounting Heights
7,250 69 105 20'
6,750 69 98
5,600 58 97
4,700 47 100
4,100 60 68
3,700 38 97
2,200 21 105 10'
IQa
Standard Models
www.dialight.com
Ratings and Certifications
• UL 844 • NEMA 4X • ABS • CII E,F,G
• UL 1598/A • 5yr full performance warranty • CID1 B,C,D • CIII
• IP66 • L70 rated for >150,000 hours • CID2 A, B,C, D • DLC listed "Al features not available on every model. Please refer to product part number pages for model specifics.
Temperature Ratings
Ambient Temperature Range Ambient Temperature Range T4A Temperature Code T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)
Specifications
Voltage options: 100 - 277V AC
347 - 480V AC
24 - 48V DC
Operating temp: -40°F to +149°F (-40°C to +65°C)
Power factor: >0.9
THD: <20%
Surge protection:
100 - 277V AC
1 kV line to line, 2 kV line to ground
347 - 480V AC
6 kV line to line, 6 kV line to ground
Comparison
Warranty L70
T-Rating
Dialight Area Light 5yr >150,000
T5
Metal Halide 1 6,000
T2
Sodium High Pressure
20,000 T2A
45° Wall Mount Models Dimension are in Inches [mm]
12 lbs (5.5 kg
18 lbs (8.2 kg)
17 lbs (7.8 kg)
18 lbs (8.1 kg)
13 lbs (7.5 kg)
20 lbs (10.2 kg)
19 lbs (9.8 kg)
20 lbs (10.1 kg)
(1) Threaded 3/4" NPT rear 10' (3.5m) STOOW Power Cord (Except when ordered with mounting bracket)
SafeSite Hazardous Application| Area Light
www.dialight.com 75
Ratings and Certifications
• UL 844 • NEMA 4X • ABS • CII E,F,G
• UL 1598/A • 5yr full performance warranty • CID1 B,C,D • CIII
• IP66 • L70 rated for >150,000 hours • CID2 A,B,C,D • DLC listed
Temperature Ratings
Ambient Temperature Range T4A Temperature Code
Ambient Temperature Range T5 Temperature Code
-40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C)
Lumens Wattage lm/W Mounting Heights
7,250 69 105 20’
6,750 69 98
5,600 58 97
4,700 47 100
4,100 60 68
3,700 38 97
2,200 21 105 10’
Mechanical information
Fixture weight:
Standard: 12 lbs (5.5 kg
Wall mount: 18 lbs (8.2 kg)
45o Wall mount: 17 lbs (7.8 kg)
45o Stanchion mount: 18 lbs (8.1 kg)
Shipping weight:
Standard: 13 lbs (7.5 kg)
Wall mount: 20 lbs (10.2 kg)
45o Wall mount: 19 lbs (9.8 kg)
45o Stanchion mount: 20 lbs (10.1 kg)
Mounting: (1) Threaded 3/4” NPT rear
Cabling:10’ (3.5m) STOOW Power Cord(Except when ordered with mounting bracket)
ComparisonWarranty L70 T-Rating
Dialight Area Light 5yr >150,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium
1 20,000 T2A
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
347 - 480V AC Lens:24 - 48V DC HZD Polycarbonate or Glass
Operating temp: -40°F to +149°F (-40°C to +65°C) HZF Poly with Antistatic Coat
Power factor: >0.9 HZC Tempered glass
THD: <20% CRI: 75
Surge protection: CCT: 5000K (cool white)
100 – 277V AC 1 kV line to line, 2 kV line to ground 4000K (neutral white)
347 – 480V AC 6 kV line to line, 6 kV line to ground
*All features not available on every model. Please refer to product part number pages for model specifics.
Dimensions
Dimension are in Inches [mm]
Standard Models Wall Mount Models
45o Stanchion Mount Models 45o Wall Mount Models
Standard Models Wall Mount Models 45o Stanchion Mount Models 45o Wall Mount Models
Light Distribution Patterns
360° Light Distribution Pattern
180° Light Distribution Pattern
Wide Throw
SafeSite® LED Area Lightfor Hazardous applications
SafeSite
Hazardous Application I Area Light
SafeSite® LED Area Light - UL 844 Class I, Div. 2 )rdering Information Classifications: CID2 A, B, C, D
1:1:11 Part Number Mounting
HZDFC2G
HZDEC2G
HZD9C2G
HZD8C2G
HZD5C2G
HZD4C2G
HZD3C2G
HZD2C2G
HZD1C2G
HZDOC2G
HZDWC2N
HZDFC9G
3/4" NPT
HZDEC9G
3/4" NPT
HZD9C9G
3/4" NPT
HZD8C9G
3/4" NPT
HZD5C9G
3/4" NPT
HZD4C9G
3/4" NPT
HZD3C9G
3/4" NPT
HZD2C9G
3/4" NPT
HZDWC9N
3/4" NPT
HZDFC8G
3/4" NPT
HZDEC8G
3/4" NPT
HZDFC2GWO1 Wall Mount
HZD9C2GWO1 Wall Mount
HZD5C2GWO1 Wall Mount
HZD3C2GWO1 Wall Mount
HZD1C2GWO1 Wall Mount
HZDWC2NVV01 Wall Mount
HZDFC9GWO1 Wall Mount
HZD9C9GWO1 Wall Mount
HZD5C9GWO1 Wall Mount
HZD3C9GWO1 Wall Mount
HZDWC9NWO1 Wall Mount
HZDFC8GWO1 Wall Mount
CIID2 co Group B (Hydrogen) Voltage Lens CCT
Class I, Div. 2 - 3/4" NPT Models - 100-277V AC
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
Class I, Div. 2 - 3/4" NPT Models - 347-480V AC
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
Class I, Div. 2 - 3/4" NPT Models - 24 - 48V DC
24 - 48V DC Tempered glass 5000K (cool white)
24 - 48V DC Tempered glass 5000K (cool white)
Class I, Div. 2 - Wall Mount Models - 100 - 277V AC
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Tempered glass 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
Class I, Div. 2 - Wall Mount Models - 347 - 480V AC
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Tempered glass 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
Class I, Div. 2 - Wall Mount Models - 24 - 48V DC
24 - 48V DC Tempered glass 5000K (cool white)
u Lmeure
n1:1 s Fixt
ig Distribution
7,250 69 105 360
7,000 69 101 180
6,000 58 103 360
6,000 58 103 180
5,250 47 112 360
5,000 47 106 180
4,000 38 105 360
4,000 38 105 180
2,250 21 107 360
2,250 21 107 180
4,200 58 72 Wide
7,250 69 105 360
7,000 69 101 180
6,000 58 103 360
6,000 58 103 180
5,250 47 112 360
5,000 47 106 180
4,000 38 105 360
4,000 38 105 180
4,200 58 72 Wide
7,250 71 102 360
7,000 71 99 180
7,250 69 105 360
6,000 58 103 360
5,250 47 112 360
4,000 38 105 360
2,250 21 107 360
4,200 58 72 Wide
7,250 69 105 360
6,000 58 103 360
5,250 47 112 360
4,000 38 105 360
4,200 58 72 Wide
7,250 71 102 360
CID2 ClID1
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%). 180° Light Distribution Pattern models are optimized for a 45° mounting angle Part numbers listed in the above table are cool white. For neutral white model replace the 51t1 character with N Ex: I-17D2C2N becomes H7D2N2Nboa Part numbers listed in the above table come with a glass lens. For polycarbonate lens model replace the 71t1 character with N Ex: H7D8C2G>ax becomes H7D8N2N)ax
76
www.dialight.com
SafeSite Hazardous Application| Area Light
76 www.dialight.com
SafeSite® LED Area Light - UL 844Class I, Div. 2 - Ordering InformationClassifications: CID2 A, B, C, D
180° Light Distribution Pattern models are optimized for a 45° mounting anglePart numbers listed in the above table are cool white. For neutral white model replace the 5th character with N Ex: HZD2C2N becomes HZD2N2NxxxPart numbers listed in the above table come with a glass lens. For polycarbonate lens model replace the 7th character with N Ex: HZD8C2Gxxx becomes HZD8N2Nxxx
Part Number Mounting CID1 CID2 CIID1 CIID2 CIIIGroup B
(Hydrogen)Voltage Lens CCT
FixtureLumens
Watt LPWLight
Distribution Pattern
Class I, Div. 2 - 3/4” NPT Models - 100-277V AC
HZDFC2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZDEC2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 7,000 69 101 180
HZD9C2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZD8C2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103 180
HZD5C2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 5,250 47 112 360
HZD4C2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 5,000 47 106 180
HZD3C2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 4,000 38 105 360
HZD2C2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 4,000 38 105 180
HZD1C2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 2,250 21 107 360
HZD0C2G 3/4" NPT • 100 - 277V AC Tempered glass 5000K (cool white) 2,250 21 107 180
HZDWC2N 3/4" NPT • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 - 3/4” NPT Models - 347-480V AC
HZDFC9G 3/4" NPT • 347 - 480V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZDEC9G 3/4" NPT • 347 - 480V AC Tempered glass 5000K (cool white) 7,000 69 101 180
HZD9C9G 3/4" NPT • 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZD8C9G 3/4" NPT • 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103 180
HZD5C9G 3/4" NPT • 347 - 480V AC Tempered glass 5000K (cool white) 5,250 47 112 360
HZD4C9G 3/4" NPT • 347 - 480V AC Tempered glass 5000K (cool white) 5,000 47 106 180
HZD3C9G 3/4" NPT • 347 - 480V AC Tempered glass 5000K (cool white) 4,000 38 105 360
HZD2C9G 3/4" NPT • 347 - 480V AC Tempered glass 5000K (cool white) 4,000 38 105 180
HZDWC9N 3/4" NPT • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 - 3/4” NPT Models - 24 - 48V DC
HZDFC8G 3/4" NPT • 24 - 48V DC Tempered glass 5000K (cool white) 7,250 71 102 360
HZDEC8G 3/4" NPT • 24 - 48V DC Tempered glass 5000K (cool white) 7,000 71 99 180
Class I, Div. 2 - Wall Mount Models - 100 - 277V AC
HZDFC2GW01 Wall Mount • 100 - 277V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZD9C2GW01 Wall Mount • 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZD5C2GW01 Wall Mount • 100 - 277V AC Tempered glass 5000K (cool white) 5,250 47 112 360
HZD3C2GW01 Wall Mount • 100 - 277V AC Tempered glass 5000K (cool white) 4,000 38 105 360
HZD1C2GW01 Wall Mount • 100 - 277V AC Tempered glass 5000K (cool white) 2,250 21 107 360
HZDWC2NW01 Wall Mount • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 - Wall Mount Models - 347 - 480V AC
HZDFC9GW01 Wall Mount • 347 - 480V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZD9C9GW01 Wall Mount • 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZD5C9GW01 Wall Mount • 347 - 480V AC Tempered glass 5000K (cool white) 5,250 47 112 360
HZD3C9GW01 Wall Mount • 347 - 480V AC Tempered glass 5000K (cool white) 4,000 38 105 360
HZDWC9NW01 Wall Mount • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 - Wall Mount Models - 24 - 48V DC
HZDFC8GW01 Wall Mount • 24 - 48V DC Tempered glass 5000K (cool white) 7,250 71 102 360
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
SafeSite
Hazardous Application I Area Light
SafeSite® LED Area Light - UL 844 Class I, Div. 2 - Ordering Information Classification CID2 A, B, C, D
Part Number
HZDFC2GW45 45° wall mount
HZDEC2GW45 45° wall mount
HZD9C2GW45 45° wall mount
HZD8C2GW45 45° wall mount
HZD5C2GW45 45° wall mount
HZD4C2GW45 45° wall mount
HZD3C2GW45 45° wall mount
HZD2C2GW45 45° wall mount
HZD1C2GW45 45° wall mount
HZDOC2GW45 45° wall mount
HZDWC2NW45 45° wall mount
HZDFC9GW45 45° wall mount
HZDEC9GW45 45° wall mount
HZD9C9GW45 45° wall mount
HZD8C9GW45 45° wall mount
HZD5C9GW45 45° wall mount
HZD4C9GW45 45° wall mount
HZD3C9GW45 45° wall mount
HZD2C9GW45 45° wall mount
HZDWC9NW45 45° wall mount
HZDFC8GW45 45° wall mount
HZDEC8GW45 45° wall mount
HZDFC2GS45 45° Stanchion
HZDEC2GS45 45° Stanchion
HZD9C2GS45 45° Stanchion
HZD8C2GS45 45° Stanchion
HZD5C2GS45 45° Stanchion
HZD4C2GS45 45° Stanchion
HZD3C2GS45 45° Stanchion
HZD2C2GS45 45° Stanchion
HZD1C2G545 45° Stanchion
HZDOC2GS45 45° Stanchion
HZDWC2NS45 45° Stanchion
HZDFC9GS45 45° Stanchion
HZDEC9GS45 45° Stanchion
HZD9C9GS45 45° Stanchion
HZD8C9GS45 45° Stanchion
HZD5C9GS45 45° Stanchion
HZD4C9GS45 45° Stanchion
HZD3C9GS45 45° Stanchion
HZD2C9GS45 45° Stanchion
HZDWC9NS45 45° Stanchion
HZDFC8GS45 45° Stanchion
HZDEC8GS45 45° Stanchion
CID2 ClID1 CIID2 co Group B (Hydrogen) Voltage Lens CCT
Class I, Div. 2 - 45 Wall Mount Models - 100 - 277V AC
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Polycarbonate 5000K (cool white)
Class I, Div. 2 - 45° Wall Mount Models - 347 - 480V AC
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Polycarbonate 5000K (cool white)
Class I, Div. 2 - 45° Wall Mount Models - 24 - 48V DC
• 24 - 48V DC Tempered glass 5000K (cool white)
• 24 - 48V DC Tempered glass 5000K (cool white)
Class I, Div. 2 - 45° Stanchion Mount Models - 100 - 277V AC
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Tempered glass 5000K (cool white)
• 100 - 277V AC Polycarbonate 5000K (cool white)
Class I, Div. 2 - 45° Stanchion Mount Models - 347 - 480V AC
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Tempered glass 5000K (cool white)
• 347 - 480V AC Polycarbonate 5000K (cool white)
Class I, Div. 2 - 45° Stanchion Mount Models - 24 - 48V DC
24 - 48V DC Tempered glass 5000K (cool white)
24 - 48V DC Tempered glass 5000K (cool white)
Fixture Lumens
ig Distribution
7,250 69 105 360
7,000 69 101 180
6,000 58 103 360
6,000 58 103 180
5,250 47 112 360
5,000 47 106 180
4,000 38 105 360
4,000 38 105 180
2,250 21 107 360
2,250 21 107 180
4,200 58 72 Wide
7,250 69 105 360
7,000 69 101 180
6,000 58 103 360
6,000 58 103 180
5,250 47 112 360
5,000 47 106 180
4,000 38 105 360
4,000 38 105 180
4,200 58 72 Wide
7,250 71 102 360
7,000 71 99 180
7,250 69 105 360
7,000 69 101 180
6,000 58 103 360
6,000 58 103 180
5,250 47 112 360
5,000 47 106 180
4,000 38 105 360
4,000 38 105 180
2,250 21 107 360
2,250 21 107 180
4,200 58 72 Wide
7,250 69 105 360
7,000 69 101 180
6,000 58 103 360
6,000 58 103 180
5,250 47 112 360
5,000 47 106 180
4,000 38 105 360
4,000 38 105 180
4,200 58 72 Wide
7,250 71 102 360
7,000 71 99 180 Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%). 180° Light Distribution Pattern models are optimized for a 45° mounting angle Part numbers listed in the above table are cool white. For neutral white model replace the 5th character with Part numbers listed in The above table come with a glass lens. For polycarbonate lens model replace the 7th www.dialight.com
N Ex: HZD2C2N becomes HZD2N2 N>c<x character with N Ex: H7D8C2Gmx becomes I-17D8N2N)oo<
77
SafeSite Hazardous Application| Area Light
www.dialight.com 77
SafeSite® LED Area Light - UL 844Class I, Div. 2 - Ordering InformationClassifications: CID2 A, B, C, D
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Part Number Mounting CID1 CID2 CIID1 CIID2 CIIIGroup B
(Hydrogen)Voltage Lens CCT
FixtureLumens
Watt LPWLight
Distribution Pattern
Class I, Div. 2 - 45 Wall Mount Models - 100 - 277V AC
HZDFC2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZDEC2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 7,000 69 101 180
HZD9C2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZD8C2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103 180
HZD5C2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 5,250 47 112 360
HZD4C2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 5,000 47 106 180
HZD3C2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 4,000 38 105 360
HZD2C2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 4,000 38 105 180
HZD1C2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 2,250 21 107 360
HZD0C2GW45 45o wall mount • 100 - 277V AC Tempered glass 5000K (cool white) 2,250 21 107 180
HZDWC2NW45 45o wall mount • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 - 45º Wall Mount Models - 347 - 480V AC
HZDFC9GW45 45o wall mount • 347 - 480V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZDEC9GW45 45o wall mount • 347 - 480V AC Tempered glass 5000K (cool white) 7,000 69 101 180
HZD9C9GW45 45o wall mount • 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZD8C9GW45 45o wall mount • 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103 180
HZD5C9GW45 45o wall mount • 347 - 480V AC Tempered glass 5000K (cool white) 5,250 47 112 360
HZD4C9GW45 45o wall mount • 347 - 480V AC Tempered glass 5000K (cool white) 5,000 47 106 180
HZD3C9GW45 45o wall mount • 347 - 480V AC Tempered glass 5000K (cool white) 4,000 38 105 360
HZD2C9GW45 45o wall mount • 347 - 480V AC Tempered glass 5000K (cool white) 4,000 38 105 180
HZDWC9NW45 45o wall mount • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 - 45º Wall Mount Models - 24 - 48V DC
HZDFC8GW45 45o wall mount • 24 - 48V DC Tempered glass 5000K (cool white) 7,250 71 102 360
HZDEC8GW45 45o wall mount • 24 - 48V DC Tempered glass 5000K (cool white) 7,000 71 99 180
Class I, Div. 2 - 45º Stanchion Mount Models - 100 - 277V AC
HZDFC2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZDEC2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 7,000 69 101 180
HZD9C2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZD8C2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103 180
HZD5C2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 5,250 47 112 360
HZD4C2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 5,000 47 106 180
HZD3C2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 4,000 38 105 360
HZD2C2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 4,000 38 105 180
HZD1C2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 2,250 21 107 360
HZD0C2GS45 45º Stanchion • 100 - 277V AC Tempered glass 5000K (cool white) 2,250 21 107 180
HZDWC2NS45 45º Stanchion • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 - 45º Stanchion Mount Models - 347 - 480V AC
HZDFC9GS45 45º Stanchion • 347 - 480V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZDEC9GS45 45º Stanchion • 347 - 480V AC Tempered glass 5000K (cool white) 7,000 69 101 180
HZD9C9GS45 45º Stanchion • 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZD8C9GS45 45º Stanchion • 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103 180
HZD5C9GS45 45º Stanchion • 347 - 480V AC Tempered glass 5000K (cool white) 5,250 47 112 360
HZD4C9GS45 45º Stanchion • 347 - 480V AC Tempered glass 5000K (cool white) 5,000 47 106 180
HZD3C9GS45 45º Stanchion • 347 - 480V AC Tempered glass 5000K (cool white) 4,000 38 105 360
HZD2C9GS45 45º Stanchion • 347 - 480V AC Tempered glass 5000K (cool white) 4,000 38 105 180
HZDWC9NS45 45º Stanchion • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 - 45º Stanchion Mount Models - 24 - 48V DC
HZDFC8GS45 45º Stanchion • 24 - 48V DC Tempered glass 5000K (cool white) 7,250 71 102 360
HZDEC8GS45 45º Stanchion • 24 - 48V DC Tempered glass 5000K (cool white) 7,000 71 99 180
180° Light Distribution Pattern models are optimized for a 45° mounting anglePart numbers listed in the above table are cool white. For neutral white model replace the 5th character with N Ex: HZD2C2N becomes HZD2N2NxxxPart numbers listed in the above table come with a glass lens. For polycarbonate lens model replace the 7th character with N Ex: HZD8C2Gxxx becomes HZD8N2Nxxx
co Group B (Hydrogen) Voltage Part Number Min CID2 ClID1 CIID2 Lens CCT
Fixture Lumens
ig t Distribution
HZDFC9N
HZDEC9N
HZD9C9N
HZD8CN
HZD5C9N
HZD4C9N
HZD3C9N
HZD2C9N
HZDWC9N
HZFFC8G
HZFEC8G
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
HZFFC2NWO1 Wall Mount
HZF9C2NWO1 Wall Mount
HZF5C2NWO1 Wall Mount
HZF3C2NWO1 Wall Mount
HZF1C2NWO1 Wall Mount
HZFWC2NWO1 Wall Mount
HZFFC9NWO1 Wall Mount
HZF9C9NVV01 Wall Mount
HZF5C9NVV01 Wall Mount
HZF3C9NWO1 Wall Mount
HZFWC9NVV01 Wall Mount
HZFEC8NWO1 Wall Mount
SafeSite
Hazardous Application I Area Light
SafeSite® LED Area Light - UL 844 Class I, Div. 2 / Class II / Class Ill - Ordering Information Classifications: CID2 A, B, C, D • ClID1 E, F, G • CIID2 F, G • CIII
Class I, Div. 2 / Class II / Class III - 3/4" NPT Models - 100-277V AC
• • •
• • •
•
• • • • • • • • • • • • •
• •
•
•
• •
•
•
•
•
I
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
24 - 48V DC Polycarbonate 5000K (cool white)
24 - 48V DC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
100 - 277V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
347 - 480V AC Polycarbonate 5000K (cool white)
24 - 48V DC Polycarbonate 5000K (cool white)
7,250 69 105 360
7,000 69 101 180
6,000 58 103 360
6,000 58 103 180
5,250 47 112 360
5,000 47 106 180
4,000 38 105 360
4,000 38 105 180
2,250 21 107 360
2,250 21 107 180
4,200 58 72 Wide
7,250 69 105 360
7,000 69 101 180
6,000 58 103 360
6,000 58 103 180
5,250 47 112 360
5,000 47 106 180
4,000 38 105 360
4,000 38 105 180
4,200 58 72 Vvide
7,250 71 102 360
7,000 71 99 180
7,250 69 105 360
6,000 58 103 360
5,250 47 112 360
4,000 38 105 360
2,250 21 107 360
4,200 58 72 VVide
7,250 69 105 360
6,000 58 103 360
5,250 47 112 360
4,000 38 105 360
4,200 58 72 Vvide
7,000 71 99 180
HZFFC2N 3/4" NPT
HZFEC2N 3/4" NPT
HZF9C2N 3/4" NPT
HZF8C2N 3/4" NPT
HZF5C2N 3/4" NPT
HZF4C2N 3/4" NPT
HZF3C2N 3/4" NPT
HZF2C2N 3/4" NPT
HZF1C2N 3/4" NPT
HZFOC2N 3/4" NPT
HZFWC2N 3/4" NPT •
Class I, Div. 2 / Class II / Class III - 3/4" NPT Models - 347-480VAC
Class I, Div. 2 / Class II / Class III - 3/4" NPT Models - 24 - 48V DC
Class I, Div. 2 / Class II / Class III - Wall Mount Models - 100 - 277V AC
Class I, Div. 2 / Class II / Class III - Wall Mount Models - 347 - 480VAC
Class I, Div. 2 / Class II / Class III - Wall Mount Models - 24 - 48V DC
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%). Part numbers listed in the above table are cool white. For neutral white model replace the 51h character with N Ex: HZF2C2N becomes H7F2N2Nboa Part numbers listed in the above table are available in glass lens. For glass lens, replace the 7th character with N Ex: H7F2C2N>ax becomes H7F2C2G)ax
78
www.dialight.com
SafeSite Hazardous Application| Area Light
78 www.dialight.com
SafeSite® LED Area Light - UL 844Class I, Div. 2 / Class II / Class III - Ordering InformationClassifications: CID2 A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Part Number Mounting CID1 CID2 CIID1 CIID2 CIIIGroup B
(Hydrogen)Voltage Lens CCT
FixtureLumens
Watt LPWLight
Distribution Pattern
Class I, Div. 2 / Class II / Class III - 3/4” NPT Models - 100-277V AC
HZFFC2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZFEC2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZF9C2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF8C2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZF5C2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF4C2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZF3C2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF2C2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZF1C2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 360
HZF0C2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 180
HZFWC2N 3/4" NPT • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III - 3/4” NPT Models - 347-480V AC
HZDFC9N 3/4" NPT • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZDEC9N 3/4" NPT • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZD9C9N 3/4" NPT • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZD8CN 3/4" NPT • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZD5C9N 3/4" NPT • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZD4C9N 3/4" NPT • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZD3C9N 3/4" NPT • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZD2C9N 3/4" NPT • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZDWC9N 3/4" NPT • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III - 3/4” NPT Models - 24 - 48V DC
HZFFC8G 3/4" NPT • • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,250 71 102 360
HZFEC8G 3/4" NPT • • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,000 71 99 180
Class I, Div. 2 / Class II / Class III - Wall Mount Models - 100 - 277V AC
HZFFC2NW01 Wall Mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZF9C2NW01 Wall Mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF5C2NW01 Wall Mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF3C2NW01 Wall Mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF1C2NW01 Wall Mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 360
HZFWC2NW01 Wall Mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III - Wall Mount Models - 347 - 480V AC
HZFFC9NW01 Wall Mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZF9C9NW01 Wall Mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF5C9NW01 Wall Mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF3C9NW01 Wall Mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZFWC9NW01 Wall Mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III - Wall Mount Models - 24 - 48V DC
HZFEC8NW01 Wall Mount • • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,000 71 99 180
Part numbers listed in the above table are cool white. For neutral white model replace the 5th character with N Ex: HZF2C2N becomes HZF2N2NxxxPart numbers listed in the above table are available in glass lens. For glass lens, replace the 7th character with N Ex: HZF2C2Nxxx becomes HZF2C2Gxxx
SafeSite Hazardous Application I Area Light
79
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%). Part numbers listed in the above table are cool white. For neutral white model replace the 5th character with N Ex: H7D2C2N becomes H7D2N2N>ax Part numbers listed in the above table are available in glass lens. For glass lens, replace the 7th character with N Ex: H7F2C2Lboa becomes H7F2C2G>ax www.dialight.com
SafeSite® LED Area Light - UL 844 Class I, Div. 2 / Class II / Class Ill - Orderina Information Classification, CID1 B, C, D CID2 A, B, C, D CIID1 E, F, G CIID2 F, G CIII
CCT ig
Distribution CID2 ClID1 LPW Fixture Lumens
Part Number
Class I, Div. 2 / Class II / Class III - 45° Wall Mount Models - 100 - 277V AC
HZFFC2NW45 45° wall mount • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZFEC2NW45 45° wall mount MI • • I 100 - 277V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZF9C2NW45 45° wall mount • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF8C2NW45 45° wall mount MI • • I 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZF5C2NW45 45° wall mount • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF4C2NW45 45° wall mount • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZF3C2NW45 45° wall mount • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF2C2NW45 45° wall mount • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZF1C2NW45 45° wall mount • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 360
HZFOC2NW45 45° wall mount • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 180
HZFWC2NW45 45° wall mount • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III - 45° Wall Mount Models - 347 - 480V AC
HZFFC9NW45 45° wall mount • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZFEC9NW45 45° wall mount • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZF9C9NW45 45° wall mount • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF8C9NW45 45° wall mount • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZF5C9NW45 45° wall mount • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF4C9NW45 45° wall mount • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZF3C9NW45 45° wall mount • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF2C9NW45 45° wall mount • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZFWC9NW45 45° wall mount • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Vvide
Class I, Div. 2 / Class II / Class III - 45° Wall Mount Models - 24 - 48V DC
HZFFC8NW45 45° wall mount • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,250 71 102 360
HZFEC8NW45 45° wall mount • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,000 71 99 180
Class I, Div. 2 / Class II / Class III- 45° Stanchion Mount Models - 100 - 277V AC
HZFFC2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZFEC2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZF9C2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF8C2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZF5C2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF4C2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZF3C2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF2C2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZF1 C2N545 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 360
HZFOC2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 180
HZFWC2NS45 45° Stanchion • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III- 45° Stanchion Mount Models - 347 - 480V AC
HZFFC9NS45 45° Stanchion • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZFEC9NS45 45° Stanchion • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZF9C9NS45 45° Stanchion • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF8C9NS45 45° Stanchion • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZF5C9NS45 45° Stanchion • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF4C9NS45 45° Stanchion • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZF3C9NS45 45° Stanchion • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF2C9NS45 45° Stanchion • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZFWC9NS45 45° Stanchion • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III - 45° Stanchion Mount Models - 24 - 48V DC
HZFFC8NS45 45° Stanchion • • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,250 71 102 360
HZFEC8NS45 45° Stanchion •_••==1• 24 - 48V DC Polycarbonate 5000K (cool white) 7,000 71 99 180
Voltage
Lens Group B (Hydrogen) ■ CIID2
SafeSite Hazardous Application| Area Light
www.dialight.com 79
SafeSite® LED Area Light - UL 844Class I, Div. 2 / Class II / Class III - Ordering InformationClassifications: CID1 B, C, D • CID2 A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
Part numbers listed in the above table are cool white. For neutral white model replace the 5th character with N Ex: HZD2C2N becomes HZD2N2NxxxPart numbers listed in the above table are available in glass lens. For glass lens, replace the 7th character with N Ex: HZF2C2Nxxx becomes HZF2C2Gxxx
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
Part Number Mounting CID1 CID2 CIID1 CIID2 CIIIGroup B
(Hydrogen)Voltage Lens CCT
FixtureLumens
Watt LPWLight
Distribution Pattern
Class I, Div. 2 / Class II / Class III - 45º Wall Mount Models - 100 - 277V AC
HZFFC2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZFEC2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZF9C2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF8C2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZF5C2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF4C2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZF3C2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF2C2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZF1C2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 360
HZF0C2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 180
HZFWC2NW45 45o wall mount • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III - 45º Wall Mount Models - 347 - 480V AC
HZFFC9NW45 45o wall mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZFEC9NW45 45o wall mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZF9C9NW45 45o wall mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF8C9NW45 45o wall mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZF5C9NW45 45o wall mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF4C9NW45 45o wall mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZF3C9NW45 45o wall mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF2C9NW45 45o wall mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZFWC9NW45 45o wall mount • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III - 45º Wall Mount Models - 24 - 48V DC
HZFFC8NW45 45o wall mount • • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,250 71 102 360
HZFEC8NW45 45o wall mount • • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,000 71 99 180
Class I, Div. 2 / Class II / Class III- 45º Stanchion Mount Models - 100 - 277V AC
HZFFC2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZFEC2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZF9C2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF8C2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZF5C2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF4C2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZF3C2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF2C2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZF1C2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 360
HZF0C2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 2,250 21 107 180
HZFWC2NS45 45º Stanchion • • • • 100 - 277V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III- 45º Stanchion Mount Models - 347 - 480V AC
HZFFC9NS45 45º Stanchion • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,250 69 105 360
HZFEC9NS45 45º Stanchion • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 7,000 69 101 180
HZF9C9NS45 45º Stanchion • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 360
HZF8C9NS45 45º Stanchion • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 6,000 58 103 180
HZF5C9NS45 45º Stanchion • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,250 47 112 360
HZF4C9NS45 45º Stanchion • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 5,000 47 106 180
HZF3C9NS45 45º Stanchion • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 360
HZF2C9NS45 45º Stanchion • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,000 38 105 180
HZFWC9NS45 45º Stanchion • • • • 347 - 480V AC Polycarbonate 5000K (cool white) 4,200 58 72 Wide
Class I, Div. 2 / Class II / Class III - 45º Stanchion Mount Models - 24 - 48V DC
HZFFC8NS45 45º Stanchion • • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,250 71 102 360
HZFEC8NS45 45º Stanchion • • • • 24 - 48V DC Polycarbonate 5000K (cool white) 7,000 71 99 180
Lim CID1
Classifications: CID2 A, B, C, D
Part Number
HZCFC2N
HZCEC2N
HZC9C2N
HZC8C2N
HZC5C2N
HZC4C2N
HZC3C2N
HZC2C2N
HZC1C2N
HZCOC2N
HZCFC9N
HZCEC9N
HZC9C9N
HZC8C9N
HZC5C9N
HZC4C9N
HZC3C9N
HZC2C9N
HZCFC8N
HZCEC8N
HZPFC2N
HZPEC2N
HZP9C2N
HZP8C2N
HZP5C2N
HZP4C2N
HZP3C2N
HZP2C2N
HZPOC2N
HZPFC9N
HZPEC9N
HZP9C9N
HZP8C9N
HZP5C9N
HZP4C9N
HZP3C9N
HZP2C9N
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
HZPFC8N 3/4" NPT •
SafeSite
SafeSite® LED Area Light - UL 844 Class I, Div. 1 Orderina Information
Hazardous Application I Area Light
HZPEC8N 3/4" NPT All values typical unless otherwise stat 180° Light Distribution Pattern models Part numbers listed in the above table
ClID1 E, F, G ClID2 F, G • CIII
ClID1 CIID2 Group B (Hydrogen) Voltage Lens CCT
Fixture Lumens
LPW
Class I, Div. 1 - 3/4" NPT Models - 100 - 277V AC
100 - 277V AC Tempered glass 5000K (cool white) 7,250 69 105
100 - 277V AC Tempered glass 5000K (cool white) 6,750 69 98
100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103
100 - 277V AC Tempered glass 5000K (cool white) 5,700 58 98
100 - 277V AC Tempered glass 5000K (cool white) 5,200 47 111 • 100 - 277V AC Tempered glass 5000K (cool white) 4,700 47 100
100 - 277V AC Tempered glass 5000K (cool white) 4,100 38 108
100 - 277V AC Tempered glass 5000K (cool white) 3,700 38 97
100 - 277V AC Tempered glass 5000K (cool white) 2,200 21 105
100 - 277V AC Tempered glass 5000K (cool white) 2,200 21 105
Class I, Div. 1 - 3/4" NPT Models - 347-480V AC
347 - 480V AC Tempered glass 5000K (cool white) 7,250 69 105
347 - 480V AC Tempered glass 5000K (cool white) 6,750 69 98
347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103
347 - 480V AC Tempered glass 5000K (cool white) 5,700 58 98
347 - 480V AC Tempered glass 5000K (cool white) 5,200 47 111
347 - 480V AC Tempered glass 5000K (cool white) 4,700 47 100
347 - 480V AC Tempered glass 5000K (cool white) 4,100 38 108
347 - 480V AC Tempered glass 5000K (cool white) 3,700 38 97
Class I, Div. 1 - 3/4" NPT Models - 24 - 48V DC
24 - 48V DC Tempered glass 5000K (cool white) 7,250 71 102
24 - 48V DC Tempered glass 5000K (cool white) 7,000 71 99
Class I, Div. 1 - 3/4" NPT Models - Hydrogen group B - 100 - 277V AC
• 100 - 277V AC Tempered glass 5000K (cool white) 7,250 69 105
• 100 - 277V AC Tempered glass 5000K (cool white) 6,750 69 98
• 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103
• 100 - 277V AC Tempered glass 5000K (cool white) 5,700 58 98
• 100 - 277V AC Tempered glass 5000K (cool white) 5,200 47 111
• 100 - 277V AC Tempered glass 5000K (cool white) 4,700 47 100
• 100 - 277V AC Tempered glass 5000K (cool white) 4,100 38 108
• 100 - 277V AC Tempered glass 5000K (cool white) 3,700 38 97
• 100 - 277V AC Tempered glass 5000K (cool white) 2,200 21 105
Class I, Div. 1 - 3/4" NPT Models - Hydrogen group B - 347 - 480V AC
• 347 - 480V AC Tempered glass 5000K (cool white) 7,250 69 105
• 347 - 480V AC Tempered glass 5000K (cool white) 6,750 69 98
• 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103
• 347 - 480V AC Tempered glass 5000K (cool white) 5,700 58 98
• 347 - 480V AC Tempered glass 5000K (cool white) 5,200 47 111 • • 347 - 480V AC Tempered glass 5000K (cool white) 4,700 47 100
• 347 - 480V AC Tempered glass 5000K (cool white) 4,100 38 108
• I 347 - 480V AC Tempered glass 5000K (cool white) 3,700 38 97
Class I, Div. 1 - 3/4" NPT Models - Hydrogen group B - 24 - 48V DC
• 24 - 48V DC Tempered glass 5000K (cool white) 7,250 71 102
I • MIL •
24 - 48V DC Tempered glass 5000K (cool white) 7,000 71 99 • ed, Lumen values are typical (tolerance +1- 10%). are optimized for a 45° mounting angle are cool white. For neutral white model replace the 51h character with N Ex: H7C2Q2N>c<x becomes H7C2N2Nboa
ig t Distribution
360
180
360
180
360
180
360
180
360
180
360
180
360
180
360
180
360
180
360
180
360
180
360
180
360
180
360
180
180
360
180
360
180
360
180
360
180
360
180
80
www.dialight.com
SafeSite Hazardous Application| Area Light
80 www.dialight.com
SafeSite® LED Area Light - UL 844Class I, Div. 1 - Ordering InformationClassifications: CID2 A, B, C, D • CIID1 E, F, G • CIID2 F, G • CIII
Part Number Mounting CID1 CID2 CIID1 CIID2 CIIIGroup B
(Hydrogen)Voltage Lens CCT
FixtureLumens
Watt LPWLight
Distribution Pattern
Class I, Div. 1 - 3/4” NPT Models - 100 - 277V AC
HZCFC2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZCEC2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 6,750 69 98 180
HZC9C2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZC8C2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 5,700 58 98 180
HZC5C2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 5,200 47 111 360
HZC4C2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 4,700 47 100 180
HZC3C2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 4,100 38 108 360
HZC2C2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 3,700 38 97 180
HZC1C2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 2,200 21 105 360
HZC0C2N 3/4" NPT • • 100 - 277V AC Tempered glass 5000K (cool white) 2,200 21 105 180
Class I, Div. 1 - 3/4” NPT Models - 347-480V AC
HZCFC9N 3/4" NPT • • 347 - 480V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZCEC9N 3/4" NPT • • 347 - 480V AC Tempered glass 5000K (cool white) 6,750 69 98 180
HZC9C9N 3/4" NPT • • 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZC8C9N 3/4" NPT • • 347 - 480V AC Tempered glass 5000K (cool white) 5,700 58 98 180
HZC5C9N 3/4" NPT • • 347 - 480V AC Tempered glass 5000K (cool white) 5,200 47 111 360
HZC4C9N 3/4" NPT • • 347 - 480V AC Tempered glass 5000K (cool white) 4,700 47 100 180
HZC3C9N 3/4" NPT • • 347 - 480V AC Tempered glass 5000K (cool white) 4,100 38 108 360
HZC2C9N 3/4" NPT • • 347 - 480V AC Tempered glass 5000K (cool white) 3,700 38 97 180
Class I, Div. 1 - 3/4” NPT Models - 24 - 48V DC
HZCFC8N 3/4" NPT • • 24 - 48V DC Tempered glass 5000K (cool white) 7,250 71 102 360
HZCEC8N 3/4" NPT • • 24 - 48V DC Tempered glass 5000K (cool white) 7,000 71 99 180
Class I, Div. 1 - 3/4” NPT Models - Hydrogen group B - 100 - 277V AC
HZPFC2N 3/4" NPT • • • 100 - 277V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZPEC2N 3/4" NPT • • • 100 - 277V AC Tempered glass 5000K (cool white) 6,750 69 98 180
HZP9C2N 3/4" NPT • • • 100 - 277V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZP8C2N 3/4" NPT • • • 100 - 277V AC Tempered glass 5000K (cool white) 5,700 58 98 180
HZP5C2N 3/4" NPT • • • 100 - 277V AC Tempered glass 5000K (cool white) 5,200 47 111 360
HZP4C2N 3/4" NPT • • • 100 - 277V AC Tempered glass 5000K (cool white) 4,700 47 100 180
HZP3C2N 3/4" NPT • • • 100 - 277V AC Tempered glass 5000K (cool white) 4,100 38 108 360
HZP2C2N 3/4" NPT • • • 100 - 277V AC Tempered glass 5000K (cool white) 3,700 38 97 180
HZP0C2N 3/4" NPT • • • 100 - 277V AC Tempered glass 5000K (cool white) 2,200 21 105 180
Class I, Div. 1 - 3/4” NPT Models - Hydrogen group B - 347 - 480V AC
HZPFC9N 3/4" NPT • • • 347 - 480V AC Tempered glass 5000K (cool white) 7,250 69 105 360
HZPEC9N 3/4" NPT • • • 347 - 480V AC Tempered glass 5000K (cool white) 6,750 69 98 180
HZP9C9N 3/4" NPT • • • 347 - 480V AC Tempered glass 5000K (cool white) 6,000 58 103 360
HZP8C9N 3/4" NPT • • • 347 - 480V AC Tempered glass 5000K (cool white) 5,700 58 98 180
HZP5C9N 3/4" NPT • • • 347 - 480V AC Tempered glass 5000K (cool white) 5,200 47 111 360
HZP4C9N 3/4" NPT • • • 347 - 480V AC Tempered glass 5000K (cool white) 4,700 47 100 180
HZP3C9N 3/4" NPT • • • 347 - 480V AC Tempered glass 5000K (cool white) 4,100 38 108 360
HZP2C9N 3/4" NPT • • • 347 - 480V AC Tempered glass 5000K (cool white) 3,700 38 97 180
Class I, Div. 1 - 3/4” NPT Models - Hydrogen group B - 24 - 48V DC
HZPFC8N 3/4" NPT • • • 24 - 48V DC Tempered glass 5000K (cool white) 7,250 71 102 360
HZPEC8N 3/4" NPT • • • 24 - 48V DC Tempered glass 5000K (cool white) 7,000 71 99 180
180° Light Distribution Pattern models are optimized for a 45° mounting anglePart numbers listed in the above table are cool white. For neutral white model replace the 5th character with N Ex: HZC2C2Nxxx becomes HZC2N2Nxxx
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
CM2
CM3
TWM2
TWM3
Wall Stanchion Ceiling Quad Mount Pendant
Wall Stanchion
KPWB-75
KPWB-100
KPS-125
KPS-150
KPAF-75
KPAF-100
KPCH-75
KPCH-100
KPST-125
KPST-150
QM25 JM5
PM5
APM2
APM3
HPM2
Pendant
KPA-75
KPA-100
Ceiling
KPC-75
KPC-100
Appleton® Mercmaster III - HZXTHAP
Eaton's Crouse-Hinds - Champ® - HZXTHCH
VMX2B & VMX-2
Ceiling
VMC3B & VMC-3
VMF2B
VMB2B & VMB-2 VMD4B
VMB3B & VMB-3 VMDSB
VMSSB
Wall Stanchion
Killark® Certilite® & Certilite® V - HZXTHKL
VMA3B & VMA-3
VMC2B & VMC-2
VMX3B & VMX-3
VMX6B
VMF3B VMX9B
VMX7B
VMXBB
Pendant
VMA2B & VMA-2
SafeSite
Hazardous Application I Area Light
SafeSite® LED Area Light Retrofit Options Overview
HZD)000( models can be ordered with factory installed retrofit adapter by adding K, A C, G, or M to the end of the part number. For example, HZD8C2N becomes HZD8C2NC. Please consult factory when ordering. Retrofit options are not suitable for use in Class I Div.1 environments
C = Eaton's Crouse-Hinds - Champ® A = Appleton® Mercmaster Ill K = KiHark® Certilite® & Certilite® V G = GE Lighting Solutions - Filtr-GardTM
GE Lighting Solutions - Filtr-GardTM - HZXTHGE
Pendant Ceiling Wall Stanchion Quad Mount
3P 3F 3C 3W 5S
4P 4F 4C 4W 6S
5J
6J
www.dialight.com
81
SafeSite Hazardous Application| Area Light
www.dialight.com 81
SafeSite® LED Area Light Retrofit Options Overview
HZDXXXX models can be ordered with factory installed retrofit adapter by adding K, A, C, G, or M to the end of the part number. For example, HZD8C2N becomes HZD8C2NC. Please consult factory when ordering. Retrofit options are not suitable for use in Class I Div.1 environments
C = Eaton’s Crouse-Hinds – Champ® A = Appleton® Mercmaster III K = Killark® Certilite® & Certilite® V G = GE Lighting Solutions – Filtr-Gard™
Appleton® Mercmaster III - HZXTHAP
Pendant Ceiling Wall Stanchion
KPA-75 KPC-75 KPWB-75 KPS-125
KPA-100 KPC-100 KPWB-100 KPS-150
KPAF-75 KPST-125
KPAF-100 KPST-150
KPCH-75
KPCH-100
Eaton’s Crouse-Hinds – Champ® - HZXTHCH
Pendant Ceiling Wall Stanchion Quad Mount
APM2 CM2 TWM2 JM5 QM25
APM3 CM3 TWM3 PM5
HPM2
Killark® Certilite® & Certilite® V - HZXTHKL
Pendant Ceiling Wall Stanchion
VMA2B & VMA-2 VMX2B & VMX-2 VMB2B & VMB-2 VMD4B
VMA3B & VMA-3 VMX3B & VMX-3 VMB3B & VMB-3 VMD5B
VMC2B & VMC-2 VMX6B VMS5B
VMC3B & VMC-3 VMX7B
VMF2B VMX8B
VMF3B VMX9B
GE Lighting Solutions – Filtr-Gard™ - HZXTHGE
Pendant Ceiling Wall Stanchion Quad Mount
3P 3F 3C 3W 5S
4P 4F 4C 4W 6S
5J
6J
Suitable for: CID1
Certified to: UL 50E • UL 514A • UL 1203 • ANSI 12.12.01 • CSA C22.2 No. 213-M, No. 94.2-07 HZXRJB • 0.75" Rectangular junction box
Suitable for: CID1
Certified to: UL 50E UL 1203 • CSA C22.2 No. 94.2-07
HBXW1 • 0.75" NPT Wall mount
ISA 12.12.01
SafeSite
Hazardous Application I Area Light
SafeSite® LED Area Light Ordering Information and Mounting Accessories
Certified to: UL 50E CSA C22.2 No. 94.2-07
HZXSTAN100S
• 1.00" (1.315" Pole OD) Slip-fit stanchion mount
HZXSTAN125S • 1.25" (1.660" Pole OD) Slip-fit stanchion mount
HZXSTAN150S • 1.50" (1.900" Pole OD) Slip-fit stanchion mount
HZXSTAN200S • 2.00" (2.375" Pole OD) Slip-fit stanchion mount
HZXSTAN100T • 1.00" (1.315" Pole OD) NPT threaded stanchion mount
HZXSTAN125T • 1.25" (1.660" Pole OD) NPT threaded stanchion mount
HZXSTAN150T • 1.50" (1.900" Pole OD) NPT threaded stanchion mount
HZXSTAN200T • 2.00" (2.375" Pole OD) NPT threaded stanchion mount
Suitable for: CID2 • CIID1 • CIID2 HZXW3
• Stainless steel bracket
HZXW7 • Aluminum bracket
Suitable for: CID2 • CIID1 • CIID2
HZXW4 • Stainless steel bracket with pipe clamp
HZXW8 • Aluminum bracket with pipe clamp
Suitable for: CID2 • CIID1 • CIID2 HZXSAFEKIT
• Safety cable kit
Suitable foi CID2
Certified to UL 50E CSA C22.2 No. 94.2-07
HZXJB07: • 0.75" Ceiling / Wall / Pole mount junction box
HZXJB100 • 1.00" Ceiling / Wall / Pole mount junction box
• HZXJB125 • 1.25" Ceiling / Wall / Pole mount junction box
HZXJB150 • 1.50" Ceiling / Wall / Pole mount junction box
Suitable for: CID2 • CIID1 • CIID2
HZXSAFETABS
• Safety tabs
Suitable for: CID2
Certified t UL 50E CSA C22.2 No. 94.2-07
HZXJB075PC1 • 0.75" Junction box with photocell
HZXJB100PC1 • 1.00" Junction box with photocell
HZXJB125PC1 • 1.25" Junction box with photocell
HZXJB150PC1 • 1.50" Junction box with photocell
Suitable for: CID2
Certified to: UL 50E CSA C22.2 No. 94.2-07
HZXUJB • 0.75" Universal junction box
Suitable for: CID1
Certified to: UL 50E UL 1203 ISA 12.12.01 • CSA C22.2 No. 94.2-07
HBXC1 • 0.75" NPT Ceiling mount
82
www.dialight.com
SafeSite Hazardous Application| Area Light
82 www.dialight.com
SafeSite® LED Area LightOrdering Information and Mounting Accessories
HZXW3• Stainless steel bracket
HZXW7• Aluminum bracket
HZXSAFETABS• Safety tabs
HZXSTAN100S• 1.00” (1.315” Pole OD) Slip-fit stanchion mount
HZXSTAN125S• 1.25” (1.660” Pole OD) Slip-fit stanchion mount
HZXSTAN150S• 1.50” (1.900” Pole OD) Slip-fit stanchion mount
HZXSTAN200S• 2.00” (2.375” Pole OD) Slip-fit stanchion mount
HZXSTAN100T• 1.00” (1.315” Pole OD) NPT threaded stanchion mount
HZXSTAN125T• 1.25” (1.660” Pole OD) NPT threaded stanchion mount
HZXSTAN150T• 1.50” (1.900” Pole OD) NPT threaded stanchion mount
HZXSTAN200T• 2.00” (2.375” Pole OD) NPT threaded stanchion mount
HZXW4• Stainless steel bracket with pipe clamp
HZXW8• Aluminum bracket with pipe clamp
HZXSAFEKIT • Safety cable kit
Suitable for: CID2 • CIID1 • CIID2
Suitable for: CID2 • CIID1 • CIID2
Suitable for: CID2 • CIID1 • CIID2
Certified to: UL 50E • CSA C22.2 No. 94.2-07
HZXJB075• 0.75” Ceiling / Wall / Pole mount junction box
HZXJB100• 1.00” Ceiling / Wall / Pole mount junction box
• HZXJB125• 1.25” Ceiling / Wall / Pole mount junction box
HZXJB150• 1.50” Ceiling / Wall / Pole mount junction box
HZXJB075PC1• 0.75” Junction box with photocell
HZXJB100PC1• 1.00” Junction box with photocell
HZXJB125PC1 • 1.25” Junction box with photocell
HZXJB150PC1• 1.50” Junction box with photocell
Suitable for: CID2 Suitable for: CID2
Certified to: UL 50E • CSA C22.2 No. 94.2-07 Certified to: UL 50E • CSA C22.2 No. 94.2-07
HZXUJB• 0.75” Universal junction box
HBXC1• 0.75” NPT Ceiling mount
HZXRJB• 0.75” Rectangular junction box
HBXW1• 0.75” NPT Wall mount
Suitable for: CID2
Suitable for: CID1
Suitable for: CID1
Suitable for: CID1
Certified to: UL 50E • CSA C22.2 No. 94.2-07
Certified to: UL 50E • UL 1203 • ISA 12.12.01 • CSA C22.2 No. 94.2-07
Certified to: UL 50E • UL 1203 • ISA 12.12.01 • CSA C22.2 No. 94.2-07
Certified to: UL 50E • UL 514A • UL 1203 • ANSI 12.12.01 • CSA C22.2 No. 213-M, No. 94.2-07
Suitable for: CID2 • CIID1 • CIID2
Fixture weight: 11 lbs (6kg)
Shipping weight:
Cable entry:
16 lbs (11kg)
All cable entries are drilled and tapped see ordering options.
NICOONG oiCLE 3FACING ?OA iri
PARFFPRIL IN
16-6011
ram& ppm pour 2.dFF IMO CAM WM ENITMS
ISA
CI-244)
Narrow Optic Oval Opt c (55)(35°) Oval Optic (35° x55°)
SafeSite
Hazardous Application I Wallpack
SafeSite® LED Wallpack / Bulkhead for Hazardous applications
Ratings and Certifications
• UL 1598/A
• CID2 A,B,C,D • UL 8750
• ClID2 F,G
• IP66/67
• 5yr full performance warranty
• RoHS compliant
• L70 rated for >150,000 hours • CSA C22.2 NO.25
"Al features not available on every model. Please refer to product part number pages for model specifics.
Temperature Ratings
Ambient Temperature Range T4A Temperature Code
11W/22W -40°F to +140°F (-40°C to +60°C)
34W -40°F to +122°F (-40°C to +50°C)
Mechanical information
CRI: CCT:
Voltage options:
Operating temp: 11W/22W
34W Power factor: THD: Surge protection:
-40°F to +140°F (-40°C to +60°C) -40°F to +122°F (-40°C to +50°C) >0.9 <20% 1 kV line to line, 2 kV line to ground
Copper free LM6 alum cast High impact resistance clear glass High impact resistance clear glass 75
5650K (cool white) 4300K (neutral white)
Specifications
100 - 277V AC
Housing: 207-264V AC
Lens:
Comparison Lumens Wattage Warranty L70 T-Rating 2,250 34
Dialight Wallpack / Bulkhead 5yr >150,000 T6 2,150 34 Metal Halide 1 6,000 T2 1,200 22 High Pressure Sodium 1 20,000 T2A 600 11
Im/W
Mounting Heights
66
20' 63 55 55
10'
Dimensions
Dimension are in Inches [mm]
Light Distribution Patterns
/1.14;31F1 13F61
83 www.dialight.com
SafeSite Hazardous Application| Wallpack
www.dialight.com 83
Temperature Ratings
Ambient Temperature Range T4A Temperature Code
11W / 22W -40°F to +140°F (-40°C to +60°C)
34W -40°F to +122°F (-40°C to +50°C)
Dimensions
Light Distribution Patterns
Narrow Optic Oval Optic (55ox35o) Oval Optic (35o x55o)
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
2,250 34 66 20’
2,150 34 63
1,200 22 55
600 11 55 10’
Ratings and Certifications
• UL 1598/A • CID2 A,B,C,D
• UL 8750 • CIID2 F,G
• IP66/67 • 5yr full performance warranty
• RoHS compliant • L70 rated for >150,000 hours
• CSA C22.2 NO.25
Mechanical information
Fixture weight: 11 lbs (6kg)
Shipping weight: 16 lbs (11kg)
Cable entry: All cable entries are drilled and tapped see ordering options.
ComparisonWarranty L70 T-Rating
Dialight Wallpack / Bulkhead 5yr >150,000 T6
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Specifications
Voltage options: 100 - 277V AC Housing: Copper free LM6 alum cast 207-264V AC Lens: High impact resistance clear glass
Operating temp: High impact resistance clear glass
11W / 22W -40°F to +140°F (-40°C to +60°C) CRI: 75
34W -40°F to +122°F (-40°C to +50°C) CCT: 5650K (cool white)
Power factor: >0.9 4300K (neutral white)
THD: <20%
Surge protection: 1 kV line to line, 2 kV line to ground
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED Wallpack / Bulkheadfor Hazardous applications
SafeSite
Hazardous Application I Wallpack
SafeSite® LED Wallpack / Bulkhead Ordering Information and Mounting Accessories Classifications: CID2 A, B, C, D • ClID2 F, G
MINA11 Part Number,
Angle • •
Flush • •
Standard • •
Flush • •
Flush • •
Standard • •
Angle • •
Angle • •
Angle • •
Flush • •
Flush • •
Angle • •
Angle • •
Flush • •
Standard • •
WPC2C3HNLGC Standard
WPC4C3HNLGC Standard
•
•
•
•
VVPC2C3CALGC Angle • •
VVPC4C3CALGC Angle • •
WPC4C3CALGF Angle • •
WPC2C3CNLGC Standard • •
WEC2C4LNLGC Standard • WEC4C4LNLGC Standard • WEC5C4LNLGC Standard • WEC2C4HNLGC Standard • WEC4C4HNLGC Standard • WEC5C4HNLGC Standard • WEC2C4CNLGC Standard • • WEC4C4CNLGC Standard • WEC5C4CNLGC Standard • •
Voltage Lens
Standard Models - 100 - 277V AC
CCT Fixture
Lumens 111: Light Distribution
100-277V AC Clear tempered glass 5650K (cool white) 2,250 34 66 Oval (35° x 55°)
100-277V AC Clear tempered glass 5650K (cool white) 2,250 34 66 Oval (35° x 55°)
100-277V AC Clear tempered glass 5650K (cool white) 2,250 34 66 Narrow
100-277V AC Clear tempered glass 5650K (cool white) 2,150 34 63 Oval (550 x 35°)
100-277V AC Clear tempered glass 5650K (cool white) 2,150 34 63 Oval (55° x 35°)
100-277V AC Clear tempered glass 5650K (cool white) 2,150 34 63 Oval (55° x 35°)
100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Oval (55° x 35°)
100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Narrow
100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Narrow
100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Narrow
100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Narrow
100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Oval (35° x 55°)
100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Oval (35° x 55°)
100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Oval (35° x 55°)
100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Oval (35° x 55°)
100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Narrow
100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Oval (35° x 55°)
100-277V AC Clear tempered glass 5650K (cool white) 600 11 55 Narrow
100-277V AC Clear tempered glass 5650K (cool white) 600 11 55 Oval (35° x 55°)
100-277V AC Frosted tempered glass 5650K (cool white) 600 11 55 Oval (35° x 55°)
100-277V AC Clear tempered glass 5650K (cool white) 600 11 55 Narrow
Battery back up models - 207-264V AC
207-264V AC Clear tempered glass 5650K (cool white) 2,250 36 63 Narrow
207-264V AC Clear tempered glass 5650K (cool white) 2,250 36 63 Oval (35° X 55°)
207-264V AC Clear tempered glass 5650K (cool white) 2,150 36 63 Oval (55° X 35°)
207-264V AC Clear tempered glass 5650K (cool white) 1,200 24 50 Narrow
207-264V AC Clear tempered glass 5650K (cool white) 1,200 24 50 Oval (35° X 55°)
207-264V AC Clear tempered glass 5650K (cool white) 1,200 24 50 Oval (55° X 35°)
207-264V AC Clear tempered glass 5650K (cool white) 600 13 46 Narrow
207-264V AC Clear tempered glass 5650K (cool white) 600 13 46 Oval (35° X 55°)
207-264V AC Clear tempered glass 5650K (cool white) 600 13 46 Oval (55° X 35°)
CID2 ■
WPC4C3LALGC
WPC4C3LFLGC
VVPC2C3LNLGC
WPC5C3LFLGCE
WPC5C3LFLGC
VVPC5C3LNLGC
WPC5C3HALGF
WPC2C3HALGC
WPC2C3HALGF
WPC2C3HFLGC
VVPC2C3HFLGF
WPC4C3HALGC
WPC4C3HALGF
WPC4C3HFLGC
WPC5C3HNLGF
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Standard Option - 2 M20 entries one side. For Through wiring, Add an -E to the end of the order code. For Rear Entry, Add an -R to the end of the order code. For NPT 3/4 entries - Add an A to the end of the order code
Entry Options Standard Option
Option "E"
Option "R"
Option "H" 2 Entries One Side
2 Entries One Side, 1 Entry
Add R to the end of the 2 Entries One Side, 2 Entries Opposite Side and Opposite Side. Add E to the end
order code
1 Entry in the Rear of the order code
Add H to the end of the order code
84
www.dialight.com
SafeSite Hazardous Application| Wallpack
84 www.dialight.com
Standard Option - 2 M20 entries one side. For Through wiring, Add an -E to the end of the order code. For Rear Entry, Add an -R to the end of the order code. For NPT 3/4 entries - Add an 5 to the end of the order code
Standard Option 2 Entries One Side
Option “E”2 Entries One Side, 1 Entry
Opposite Side. Add E to the end of the order code
Option “R”Add R to the end of the
order code
Entry OptionsOption “H”
2 Entries One Side, 2 Entries Opposite Side and 1 Entry in the Rear
Add H to the end of the order code
Part Number 1 Bracket CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixture
LumensWatt Lm/W Light Distribution
Standard Models - 100 - 277V AC
WPC4C3LALGC Angle • • 100-277V AC Clear tempered glass 5650K (cool white) 2,250 34 66 Oval (35o x 55o)
WPC4C3LFLGC Flush • • 100-277V AC Clear tempered glass 5650K (cool white) 2,250 34 66 Oval (35o x 55o)
WPC2C3LNLGC Standard • • 100-277V AC Clear tempered glass 5650K (cool white) 2,250 34 66 Narrow
WPC5C3LFLGCE Flush • • 100-277V AC Clear tempered glass 5650K (cool white) 2,150 34 63 Oval (55o x 35o)
WPC5C3LFLGC Flush • • 100-277V AC Clear tempered glass 5650K (cool white) 2,150 34 63 Oval (55o x 35o)
WPC5C3LNLGC Standard • • 100-277V AC Clear tempered glass 5650K (cool white) 2,150 34 63 Oval (55o x 35o)
WPC5C3HALGF Angle • • 100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Oval (55o x 35o)
WPC2C3HALGC Angle • • 100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Narrow
WPC2C3HALGF Angle • • 100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Narrow
WPC2C3HFLGC Flush • • 100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Narrow
WPC2C3HFLGF Flush • • 100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Narrow
WPC4C3HALGC Angle • • 100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Oval (35o x 55o)
WPC4C3HALGF Angle • • 100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Oval (35o x 55o)
WPC4C3HFLGC Flush • • 100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Oval (35o x 55o)
WPC5C3HNLGF Standard • • 100-277V AC Frosted tempered glass 5650K (cool white) 1,200 22 55 Oval (35o x 55o)
WPC2C3HNLGC Standard • • 100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Narrow
WPC4C3HNLGC Standard • • 100-277V AC Clear tempered glass 5650K (cool white) 1,200 22 55 Oval (35o x 55o)
WPC2C3CALGC Angle • • 100-277V AC Clear tempered glass 5650K (cool white) 600 11 55 Narrow
WPC4C3CALGC Angle • • 100-277V AC Clear tempered glass 5650K (cool white) 600 11 55 Oval (35o x 55o)
WPC4C3CALGF Angle • • 100-277V AC Frosted tempered glass 5650K (cool white) 600 11 55 Oval (35o x 55o)
WPC2C3CNLGC Standard • • 100-277V AC Clear tempered glass 5650K (cool white) 600 11 55 Narrow
Battery back up models - 207-264V AC
WEC2C4LNLGC Standard • • 207-264V AC Clear tempered glass 5650K (cool white) 2,250 36 63 Narrow
WEC4C4LNLGC Standard • • 207-264V AC Clear tempered glass 5650K (cool white) 2,250 36 63 Oval (35° X 55°)
WEC5C4LNLGC Standard • • 207-264V AC Clear tempered glass 5650K (cool white) 2,150 36 63 Oval (55° X 35°)
WEC2C4HNLGC Standard • • 207-264V AC Clear tempered glass 5650K (cool white) 1,200 24 50 Narrow
WEC4C4HNLGC Standard • • 207-264V AC Clear tempered glass 5650K (cool white) 1,200 24 50 Oval (35° X 55°)
WEC5C4HNLGC Standard • • 207-264V AC Clear tempered glass 5650K (cool white) 1,200 24 50 Oval (55° X 35°)
WEC2C4CNLGC Standard • • 207-264V AC Clear tempered glass 5650K (cool white) 600 13 46 Narrow
WEC4C4CNLGC Standard • • 207-264V AC Clear tempered glass 5650K (cool white) 600 13 46 Oval (35° X 55°)
WEC5C4CNLGC Standard • • 207-264V AC Clear tempered glass 5650K (cool white) 600 13 46 Oval (55° X 35°)
SafeSite® LED Wallpack / BulkheadOrdering Information and Mounting AccessoriesClassifications: CID2 A, B, C, D • CIID2 F, G
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
SafeSite
Hazardous Application I Wallpack
SafeSite® LED Wallpack / Bulkhead Ordering Information and Mounting Accessories
WP-BRKT-SSAD-J • Adjustable Bracket
WP-STMB-LGOO- 22 • 1 1/2" BSP threaded
straight stanchion mounting bracket
WP-STMB-LGOO -24 • 1 1/2" NPT threaded
straight stanchion mounting bracket
WP-STMB-LG25-22 • 1 1/2" BSP threaded
25 degree stanchion mounting bracket
WP-STMB-LG25-24 • 1 1/2" NPT threaded
25 degree stanchion mounting bracket
WP-STMB-LG85-22 • 1 1/2" BSP threaded 85
degree stanchion mounting bracket
WP-STMB-LG85-24 • 1 1/2" NPT threaded 85
degree stanchion mounting bracket
WP-BRKT-LG-PF • Pipe and flush bracket
WP-STMB-LG25-22 • 1 1/2" BSP threaded
25 degree stanchion mounting bracket
WP-STMB-LG25-24 • 1 1/2" NPT threaded
25 degree stanchion mounting bracket
WPX-000799-BAT • 4Ah 3.6V Battery Module
• Replacement Battery Kit
• Battery Backup models only
WPX-001500-BATT • 10Ah 3.6V Battery Module
• Replacement Battery Kit
• Battery Backup models only
www.dialight.com 85
SafeSite Hazardous Application| Wallpack
www.dialight.com 85
SafeSite® LED Wallpack / BulkheadOrdering Information and Mounting Accessories
WP-STMB-LG00- 22• 1 1/2” BSP threaded
straight stanchion mounting bracket
WP-STMB-LG00 -24• 1 1/2” NPT threaded
straight stanchion mounting bracket
WP-STMB-LG25-22• 1 1/2” BSP threaded
25 degree stanchion mounting bracket
WP-STMB-LG25-24 • 1 1/2” NPT threaded
25 degree stanchion mounting bracket
WP-BRKT-SSAD-J• Adjustable Bracket
WP-BRKT-LG-PF• Pipe and flush bracket
WP-STMB-LG85-22• 1 1/2” BSP threaded 85
degree stanchion mounting bracket
WP-STMB-LG85-24• 1 1/2” NPT threaded 85
degree stanchion mounting bracket
WP-STMB-LG25-22• 1 1/2” BSP threaded
25 degree stanchion mounting bracket
WP-STMB-LG25-24 • 1 1/2” NPT threaded
25 degree stanchion mounting bracket
WPX-000799-BAT• 4Ah 3.6V Battery Module
• Replacement Battery Kit
• Battery Backup models only
WPX-001500-BATT• 10Ah 3.6V Battery Module
• Replacement Battery Kit
• Battery Backup models only
Im/W
100
59
Lumens
800 470
T-Rating
T2B
T3
Wattage
8 8
4;1
1
' ril!. Jii -
RTO-OW)a-004
Dimension are in Inches [mm]
Mounting Heights
15' and lower 15' and lower
RTO-OW>c<-001 ,..?,
RTO-OW,x-005
°41!1.1.
Dimensions
L70
>150,000
6,000
20,000
Comparison Warranty
5yr 1
1
Dialight RTO
Incandescent CFL
SafeSite Hazardous Application I Area Light
SafeSite® LED RTO Area Light for Hazardous applications
• UL 1598/A • UL 844
• CSA C22.2 #250
• CSA C22.2 #137
• IP66 • NEMA 4X
Ratings and Certifications
• UL50/E • CID2 A,B,C,D
• CIID1 E,F,G • ClID2 E,F,G • 5yr full performance warranty • L70 rated for >150,000 hours
"Al features not available on every model. Please refer to product part number pages for model specifics.
Mechanical information Temperature Ratings
Fixture weight: Ambient Temperature Range T3C Temperature Code
RTOOW>o<001: 2.5 lbs (1.13 kg) -40°F to +131°F (-40°C to +55°C)
RTOOW>c<005: 3.2 lbs (1.45 kg) RTOOW>o<004: 0.8 lbs (0.36 Kg) Specifications
Shipping weight: Voltage options: 100 - 277V AC Housing: Copper free aluminum RTOOW>o<001: 3.0 lbs (1.36 kg)
24 - 48V DC Lens: Polycarbonate RTOOW>c<005: 4.5 lbs (2.04 kg)
Operating temp: -40°F to +133°F CRI: 75 RTOOW>o<004: 1.4 lbs (0.64 Kg)
(-40°C to +55°C) CCT: 6000K (cool white) Mounting:
Power factor: >0.9 Pendant mount: 1" & 3/4" NPT reducer bi-directional mounting
THD: <20% Ceiling mount: 3/4" NPT 5-way surface mounting
Surge protection: 1 kV line to line Pendant mount: 3/4" NPT threaded conduit 2 kV line to ground
Light Distribution Pattern
86 www.dialight.com
SafeSite Hazardous Application| Area Light
86 www.dialight.com
Temperature Ratings
Ambient Temperature Range T3C Temperature Code
-40°F to +131°F (-40°C to +55°C)
Dimensions
RTO-0Wxx-001 RTO-0Wxx-005 RTO-0Wxx-004
Light Distribution Pattern
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
800 8 100 15’ and lower
470 8 59 15’ and lower
Ratings and Certifications
• UL 1598/A • UL50/E
• UL 844 • CID2 A,B,C,D
• CSA C22.2 #250 • CIID1 E,F,G
• CSA C22.2 #137 • CIID2 E,F,G
• IP66 • 5yr full performance warranty
• NEMA 4X • L70 rated for >150,000 hours
Mechanical information
Fixture weight:RTO0Wxx001: 2.5 lbs (1.13 kg)
RTO0Wxx005: 3.2 lbs (1.45 kg)
RTO0Wxx004: 0.8 lbs (0.36 Kg)
Shipping weight:RTO0Wxx001: 3.0 lbs (1.36 kg)
RTO0Wxx005: 4.5 lbs (2.04 kg)
RTO0Wxx004: 1.4 lbs (0.64 Kg)
Mounting:Pendant mount: 1” & 3/4” NPT reducer bi-directional mounting
Ceiling mount: 3/4” NPT 5-way surface mounting
Pendant mount: 3/4” NPT threaded conduit
ComparisonWarranty L70 T-Rating
Dialight RTO 5yr >150,000 T3C
Incandescent 1 6,000 T2B
CFL 1 20,000 T3
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
24 - 48V DC Lens: Polycarbonate
Operating temp: -40°F to +133°F CRI: 75
(-40°C to +55°C) CCT: 6000K (cool white)
Power factor: >0.9
THD: <20%
Surge protection: 1 kV line to line2 kV line to ground
*All features not available on every model. Please refer to product part number pages for model specifics.
SafeSite® LED RTO Area Lightfor Hazardous applications
SafeSite
Hazardous Application I Area Light
SafeSite® LED RTO Area Light Ordering Information and mnunting Accessories Classifications: CID2 A,B,C,D CIID1 E,F,G ClID2 E,F,D
CID1 CID2 ClID2 ■ Fixture Lumens
Part Number' Type Voltage Lens CCT
Standard Models - 100 - 277V AC
RTODW17005 Ceiling mount with junction box • 100-277V AC Polycarbonate 6000K (cool white) 800 8
RTODW17004 Pendant mount • 100-277V AC Polycarbonate 6000K (cool white) 800 8
RTODW17001 Pendant mount with junction box 100-277V AC Polycarbonate 6000K (cool white) 800 8
RTO2W17005 Ceiling mount with junction box 100-277V AC Polycarbonate 6000K (cool white) 800 8
RTO2W17004 Pendant mount 100-277V AC Polycarbonate 6000K (cool white) 800 8
RTO2W17001 Pendant mount with junction box • 100-277V AC Polycarbonate 6000K (cool white) 800 8
RTODW07005 Ceiling mount with junction box 100-277V AC Polycarbonate 6000K (cool white) 470 8
RTODW07004 Pendant mount 100-277V AC Polycarbonate 6000K (cool white) 470 8
RTODW07001 Pendant mount with junction box 100-277V AC Polycarbonate 6000K (cool white) 470 8
RTO2W07005 Ceiling mount with junction box 100-277V AC Polycarbonate 6000K (cool white) 470 8
RTO2W07004 Pendant mount 100-277V AC Polycarbonate 6000K (cool white) 470 8
RTO2W07001 Pendant mount with junction box • 100-277V AC Polycarbonate 6000K (cool white) 470 8
Standard models - 24 - 48V DC
RTODW18005 Ceiling mount with junction box 24 - 48V DC Polycarbonate 6000K (cool white) 800 8
RTODW18004 Pendant mount 24 - 48V DC Polycarbonate 6000K (cool white) 800 8
RTODW18001 Pendant mount with junction box 24 - 48V DC Polycarbonate 6000K (cool white) 800 8
RTO2W18005 Ceiling mount with junction box 24 - 48V DC Polycarbonate 6000K (cool white) 800 8
RTO2W18004 Pendant mount 24 - 48V DC Polycarbonate 6000K (cool white) 800 8
RTO2W18001 Pendant mount with junction box 24 - 48V DC Polycarbonate 6000K (cool white) 800 8
RTODW08005 Ceiling mount with junction box 24 - 48V DC Polycarbonate 6000K (cool white) 470 8
RTODW08004 Pendant mount 24 - 48V DC Polycarbonate 6000K (cool white) 470 8
RTODW08001 Pendant mount with junction box 24 - 48V DC Polycarbonate 6000K (cool white) 470 8
RTO2W08005 Ceiling mount with junction box 24 - 48V DC Polycarbonate 6000K (cool white) 470 8
RTO2W08004 Pendant mount • 24 - 48V DC Polycarbonate 6000K (cool white) 470 8
RTO2W08001 Pendant mount with junction box • 24 - 48V DC Polycarbonate 6000K (cool white) 470 8
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
ig t LPW Distribution
100 Circular
100 Circular
100 Circular
100 Circular
100 Circular
100 Circular
59 Circular
59 Circular
59 Circular
59 Circular
59 Circular
59 Circular
100 Circular
100 Circular
100 Circular
100 Circular
100 Circular
100 Circular
59 Circular
59 Circular
59 Circular
59 Circular
59 Circular
59 Circular
Pendant Mount • 3/4" NPT threaded conduit
RT01000 • Flush wall mount
Pendant Mount with Junction Box • 1" & 3/4" NPT reducer
bidirectional mounting
RTO1001 • Junction box wall mount
Ceiling Mount with Junction Box • 3/4" NPT 5-way surface
mounting
www.dialight.com 87
SafeSite Hazardous Application| Area Light
www.dialight.com 87
Classifications: CID2 A,B,C,D • CIID1 E,F,G • CIID2 E,F,D
Pendant Mount with Junction Box• 1’’ & 3/4’’ NPT reducer
bidirectional mounting
Ceiling Mount with Junction Box• 3/4’’ NPT 5-way surface
mounting
Pendant Mount• 3/4’’ NPT threaded conduit
RTO1001• Junction box wall mount
RTO1000• Flush wall mount
SafeSite® LED RTO Area LightOrdering Information and Mounting Accessories
Part Number 1 Type CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCTFixture
LumensWatt LPW
Light Distribution
PatternStandard Models - 100 - 277V AC
RTODW17005 Ceiling mount with junction box • • 100-277V AC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTODW17004 Pendant mount • • 100-277V AC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTODW17001 Pendant mount with junction box • • 100-277V AC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTO2W17005 Ceiling mount with junction box • 100-277V AC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTO2W17004 Pendant mount • 100-277V AC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTO2W17001 Pendant mount with junction box • 100-277V AC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTODW07005 Ceiling mount with junction box • • 100-277V AC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTODW07004 Pendant mount • • 100-277V AC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTODW07001 Pendant mount with junction box • • 100-277V AC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTO2W07005 Ceiling mount with junction box • 100-277V AC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTO2W07004 Pendant mount • 100-277V AC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTO2W07001 Pendant mount with junction box • 100-277V AC Polycarbonate 6000K (cool white) 470 8 59 Circular
Standard models - 24 - 48V DC
RTODW18005 Ceiling mount with junction box • • 24 - 48V DC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTODW18004 Pendant mount • • 24 - 48V DC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTODW18001 Pendant mount with junction box • • 24 - 48V DC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTO2W18005 Ceiling mount with junction box • 24 - 48V DC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTO2W18004 Pendant mount • 24 - 48V DC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTO2W18001 Pendant mount with junction box • 24 - 48V DC Polycarbonate 6000K (cool white) 800 8 100 Circular
RTODW08005 Ceiling mount with junction box • • 24 - 48V DC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTODW08004 Pendant mount • • 24 - 48V DC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTODW08001 Pendant mount with junction box • • 24 - 48V DC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTO2W08005 Ceiling mount with junction box • 24 - 48V DC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTO2W08004 Pendant mount • 24 - 48V DC Polycarbonate 6000K (cool white) 470 8 59 Circular
RTO2W08001 Pendant mount with junction box • 24 - 48V DC Polycarbonate 6000K (cool white) 470 8 59 Circular
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
• UL 1598/A • UL 8750
• UL 1012
• UL 1449
• CE
• L70 rated for >150,000 hours
• IP66 • NEMA 4X
• RoHS
• CSA C22.2 No. 250.0-08
• IDA Dark Sky
• 7yr full performance warranty
Ratings and Certifications
"AI features not available on every model. Please refer to product part number pages for model specifics.
Comparison Warranty L70 T-Rating
Dialight Street Light 7yr >150,000 T5 Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Mechanical information
Fixture weight: 65W / 83W: 131W / 165W: 190W / 252W:
Shipping weight: 65W / 83W: 131W / 165W: 190W / 252W:
Mounting:
21Ibs (12kg) 30Ibs (17kg)
391bs (20kg)
Accommodates 1.25" (1.66" OD) - 2" (2.375" OD) 31.75mm (42.16mm OD) - 50.8mm (60.32mm OD) pipe. Provision for adjustment of +/- 5° at 2.5° increments
16Ibs (7 kg) 251bs (11kg) 341bs (15 kg)
Voltage options: 100 - 277V AC Housing: Copper free aluminum 347 - 480V AC Lens: Tempered glass
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white) THD: <20% 4300K (neutral white)
Surge protection: Open circuit surge protection 10kV EPA (Sq. fl) standard per ANSI/IEEE C62.41. 65W / 83W: 0.60 2.2002 cat C high 131W/ 165W: 0.87
190W / 252W: 1.13
Lumens Wattage Im/W Mounting Heights
20,250 252 80 50' 16,000 190 84 13,300 165 81 10,900 131 83 6,800 83 82 5,500 65 85 15'
Specifications
StreetSense Hazardous Infrastructure Solutions I Streetlight
StreetSense LED Streetlight for Infrastructure applications
Dimensions
4.8 (122]
34.7 (880) - 190W .252W - 26.5 (674)- 131W, 165W
18.4 (467) - 65W, 83W
(372) 14.7 111
111111111011111iiiiiiillig Dimension are in Inches [mm]
Light Distribution Patterns
Type III 88 www.dialight.com
StreetSense Hazardous Infrastructure Solutions| Streetlight
88 www.dialight.com
Dimensions
Light Distribution Patterns
Type III
Dimension are in Inches [mm]
Lumens Wattage lm/W Mounting Heights
20,250 252 80 50’
16,000 190 84
13,300 165 81
10,900 131 83
6,800 83 82
5,500 65 85 15’
Mechanical information
Fixture weight:65W / 83W: 16lbs (7 kg)
131W / 165W: 25lbs (11kg)
190W / 252W: 34lbs (15 kg)
Shipping weight:65W / 83W: 21lbs (12kg)
131W / 165W: 30lbs (17kg)
190W / 252W: 39lbs (20kg)
Mounting: Accommodates 1.25” (1.66” OD) - 2” (2.375” OD) 31.75mm (42.16mm OD) - 50.8mm (60.32mm OD) pipe. Provision for adjustment of +/- 5° at 2.5° increments
ComparisonWarranty L70 T-Rating
Dialight Street Light 7yr >150,000 T5
Metal Halide 1 6,000 T2
High Pressure Sodium 1 20,000 T2A
Specifications
Voltage options: 100 - 277V AC Housing: Copper free aluminum
347 - 480V AC Lens: Tempered glass
Operating temp: -40°F to +149°F (-40°C to +65°C) CRI: 75
Power factor: >0.9 CCT: 5000K (cool white)
THD: <20% 4300K (neutral white)
Surge protection: Open circuit surge protection 10kV standard per ANSI/IEEE C62.41. 2.2002 cat C high
EPA (Sq. ft) 65W / 83W: 0.60
131W / 165W: 0.87
190W / 252W: 1.13
Ratings and Certifications
• UL 1598/A • IP66
• UL 8750 • NEMA 4X
• UL 1012 • RoHS
• UL 1449 • CSA C22.2 No. 250.0-08
• CE • IDA Dark Sky
• L70 rated for >150,000 hours • 7yr full performance warranty*All features not available on every model. Please refer to product part number pages for model specifics.
StreetSense LED Streetlightfor Infrastructure applications
StreetSense Infrastructure Solutions I Streetlight
StreetSense LED Streetlight Ordering Information and Mounting Accessories
Part Number' Number of Light
Engines EPA
(SQ. ft) BUG Rating Voltage Lens CCT
Standard Models - 100 - 277V AC
SL3C5CLGG 1 0.60 B1U1G1 100 - 277V AC Tempered glass 5000K (cool white)
SL3C5DLGG 1 0.60 B2U1G2 100 - 277V AC Tempered glass 5000K (cool white)
SL3C5HLGG 2 0.87 B2U1G2 100 - 277V AC Tempered glass 5000K (cool white)
SL3C5ILGG 2 0.87 B3U1G3 100 - 277V AC Tempered glass 5000K (cool white)
SL3C5RLGG 3 1.13 B3U1G3 100 - 277V AC Tempered glass 5000K (cool white)
SL3C5SLGG 3 1.13 B3U1G3 100 - 277V AC Tempered glass 5000K (cool white)
Standard models - 347 - 480V AC
SL3C7CLGG 1 0.60 B1U1G1 347 - 480V AC Tempered glass 5000K (cool white)
SL3C7DLGG 1 0.60 B2U1G2 347 - 480V AC Tempered glass 5000K (cool white)
SL3C7HLGG 2 0.87 B2U1G2 347 - 480V AC Tempered glass 5000K (cool white)
SL3C7ILGG 2 0.87 B3U1G3 347 - 480V AC Tempered glass 5000K (cool white)
SL3C7RLGG 3 1.13 B3U1G3 347 - 480V AC Tempered glass 5000K (cool white)
SL3C7SLGG 3 1.13 B3U1G3 347 - 480V AC Tempered glass 5000K (cool white)
Fixture Lumens
gt Distribution
5,500 65 85 Type III
6,800 83 82 Type III
10,900 131 83 Type III
13,300 165 81 Type III
16,000 190 84 Type III
20,250 252 80 Type III
5,500 65 85 Type III
6,800 83 82 Type III
10,900 131 83 Type III
13,300 165 81 Type III
16,000 190 84 Type III
20,250 252 80 Type III
Al values typical unless otherwise stated, Lumen values are typical (tolerance +1- 10%).
Part numbers listed in the above table are cool white. For neutral white model, replace the 4th character with N Ex: SL3C5CLGG becomes SL3N5CLGG
SLSHIELDKIT • House Side Shield
SL-PCO1R • 105 - 305V AC Photocontroller
SL-PCO2R • 312 - 382V AC Photocontroller
SL-PCO3R • 432 - 528V AC Photocontroller
www.dialight.com 89
StreetSense Infrastructure Solutions| Streetlight
www.dialight.com 89
Part numbers listed in the above table are cool white. For neutral white model, replace the 4th character with N Ex: SL3C5CLGG becomes SL3N5CLGG
Part Number 1Number of Light
EnginesEPA
(SQ. ft)BUG Rating Voltage Lens CCT
FixtureLumens
Watt LPWLight
Distribution Pattern
Standard Models - 100 - 277V AC
SL3C5CLGG 1 0.60 B1U1G1 100 - 277V AC Tempered glass 5000K (cool white) 5,500 65 85 Type III
SL3C5DLGG 1 0.60 B2U1G2 100 - 277V AC Tempered glass 5000K (cool white) 6,800 83 82 Type III
SL3C5HLGG 2 0.87 B2U1G2 100 - 277V AC Tempered glass 5000K (cool white) 10,900 131 83 Type III
SL3C5ILGG 2 0.87 B3U1G3 100 - 277V AC Tempered glass 5000K (cool white) 13,300 165 81 Type III
SL3C5RLGG 3 1.13 B3U1G3 100 - 277V AC Tempered glass 5000K (cool white) 16,000 190 84 Type III
SL3C5SLGG 3 1.13 B3U1G3 100 - 277V AC Tempered glass 5000K (cool white) 20,250 252 80 Type III
Standard models - 347 - 480V AC
SL3C7CLGG 1 0.60 B1U1G1 347 - 480V AC Tempered glass 5000K (cool white) 5,500 65 85 Type III
SL3C7DLGG 1 0.60 B2U1G2 347 - 480V AC Tempered glass 5000K (cool white) 6,800 83 82 Type III
SL3C7HLGG 2 0.87 B2U1G2 347 - 480V AC Tempered glass 5000K (cool white) 10,900 131 83 Type III
SL3C7ILGG 2 0.87 B3U1G3 347 - 480V AC Tempered glass 5000K (cool white) 13,300 165 81 Type III
SL3C7RLGG 3 1.13 B3U1G3 347 - 480V AC Tempered glass 5000K (cool white) 16,000 190 84 Type III
SL3C7SLGG 3 1.13 B3U1G3 347 - 480V AC Tempered glass 5000K (cool white) 20,250 252 80 Type III
StreetSense LED StreetlightOrdering Information and Mounting Accessories
SL-PC01R• 105 - 305V AC Photocontroller
SL-PC02R• 312 - 382V AC Photocontroller
SL-PC03R• 432 - 528V AC Photocontroller
SLSHIELDKIT• House Side Shield
All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%).
SignalF Obstruction Signals I FAA Approved
Obstruction LED Lighting Solutions FAA Approved Obstruction Lighting Solutions
Red LED Systems: L-864 and L-810 Features & Benefits • Infrared (IR) models available for improved
visibility to night vision goggles • Integrated controller • Full 5 year performance warranty • Universal 120-240V AC input • Controller can be mounted at the base of the
structure • NEMA 4x outdoor rated enclosure • Wide temperature range: -40°C to +55°C • Configurable flash rates (20, 30, or 40
flashes per minute) • Ability to operate lights in steady or flashing
mode • Optional infrared light fixtures
• Light weight design • Low power consumption • IP66 rated light fixtures • Impact and vibration resistant • Provision for padlock on the enclosure • Dry contacts for alarm monitoring/status
• Photocell alarm • L810/L864 light alarms • Operation mode (day/night) • Communication alarm • Sync alarm • Power fail alarm
Dual (Red / White) LED Systems: L-86 Features & Benefits • Infrared (IR) version available for improved
visibility to Night Vision Goggles • Integrated controller with LCD back-lit display • Optional Ethernet / Cellular based remote
monitoring / control system available • Full 5 year performance warranty • Ability to flash side markers • Universal 120-240V AC input or +/-48V DC
input • Controller can be mounted at the base of the
structure • NEMA 4x outdoor rated enclosure • Wide temperature range: -40°C to +55°C • Light weight design
5 and L-864
• Low power consumption • IP66 rated light fixtures • Impact and vibration resistant • Provisions for padlock on the enclosure • Dry contacts for alarm monitoring/status
• Photocell alarm • Communication alarm • Sync alarm • Operation mode (day/night) • White mode alarm • Red mode alarm • Power fail alarm
White LED Systems: L-865 Features & Benefits • Integrated controller with LCD back-lit display • Optional Ethernet / Cellular based remote
monitoring / control system available • Full 5 year performance warranty • Universal 120-240V AC input or +/-48V DC
input • Controller can be mounted at the base of the
structure • NEMA 4x outdoor rated enclosure • Wide temperature range: -40°C to +55°C • Light weight design • Low power consumption • IP66 rated light fixtures
• Impact and vibration resistant • Provisions for padlock on the enclosure • Dry contacts for alarm monitoring/status
• Photocell alarm • Communication alarm • Sync alarm • Operation mode (day/night) • White mode alarm • Power fail
90
www.dialight.com
Signals Obstruction Signals| FAA Approved
90 www.dialight.com
Obstruction LED Lighting SolutionsFAA Approved Obstruction Lighting Solutions
White LED Systems: L-865Features & Benefits
Dual (Red / White) LED Systems: L-865 and L-864Features & Benefits
Red LED Systems: L-864 and L-810Features & Benefits
• Infrared (IR) version available for improved visibility to Night Vision Goggles
• Integrated controller with LCD back-lit display• Optional Ethernet / Cellular based remote
monitoring / control system available• Full 5 year performance warranty• Ability to flash side markers• Universal 120-240V AC input or +/-48V DC
input• Controller can be mounted at the base of the
structure• NEMA 4x outdoor rated enclosure• Wide temperature range: -40oC to +55oC• Light weight design
• Low power consumption• IP66 rated light fixtures• Impact and vibration resistant• Provisions for padlock on the enclosure• Dry contacts for alarm monitoring/status
• Photocell alarm• Communication alarm• Sync alarm• Operation mode (day/night)• White mode alarm • Red mode alarm• Power fail alarm
• Infrared (IR) models available for improved visibility to night vision goggles
• Integrated controller• Full 5 year performance warranty• Universal 120-240V AC input• Controller can be mounted at the base of the
structure• NEMA 4x outdoor rated enclosure• Wide temperature range: -40oC to +55oC• Configurable flash rates (20, 30, or 40
flashes per minute)• Ability to operate lights in steady or flashing
mode• Optional infrared light fixtures
• Light weight design• Low power consumption• IP66 rated light fixtures• Impact and vibration resistant• Provision for padlock on the enclosure• Dry contacts for alarm monitoring/status
• Photocell alarm• L-810/L-864 light alarms• Operation mode (day/night)• Communication alarm• Sync alarm• Power fail alarm
• Integrated controller with LCD back-lit display• Optional Ethernet / Cellular based remote
monitoring / control system available• Full 5 year performance warranty• Universal 120-240V AC input or +/-48V DC
input• Controller can be mounted at the base of the
structure• NEMA 4x outdoor rated enclosure• Wide temperature range: -40oC to +55oC• Light weight design• Low power consumption• IP66 rated light fixtures
• Impact and vibration resistant• Provisions for padlock on the enclosure• Dry contacts for alarm monitoring/status
• Photocell alarm• Communication alarm• Sync alarm• Operation mode (day/night)• White mode alarm • Power fail
Signals Obstruction Signals I FAA Approved
Obstruction LED Lighting Solutions FAA Approved Obstruction Lighting Solutions
High Intensity LED Systems: L-856 / L864 Features & Benefits • Integrated controller • Full 5 year performance warranty • Universal 208 - 277V AC input • Controller can be mounted at the base of the
structure • NEMA 4x outdoor rated enclosures • Wide temperature range: -40°C to +55°C • Low power consumption • IP66 rated light fixtures • Impact and vibration resistant • Provision for padlock on the enclosure
Wind LED Lighting Systems i-eatures & i:senents • Controller integrated into flashhead • Integrated Photocell • Integrated Flasher • Full 5 year performance warranty • Universal 120-240V AC input • Wide temperature range: -40°C to +55°C • Low power consumption • IP66 rated light fixtures • Impact and vibration resistant • Dry contacts for alarm monitoring/status
• Effective intensity / power consumption • White Day = 270,000cd (220W) • White Twilight = 20,000cd (40W) • White Night = 2,000cd (30W) • Red Night = 2,000cd (30W)
• Dry contacts for alarm monitoring/status • Photocell alarm • Communication alarm • Sync alarm • Operation mode (day/night) • White mode alarm • Red mode alarm • Power fail alarm
www.dialight.com 91
Signals Obstruction Signals| FAA Approved
www.dialight.com 91
High Intensity LED Systems: L-856 / L864Features & Benefits
Wind LED Lighting SystemsFeatures & Benefits
Obstruction LED Lighting SolutionsFAA Approved Obstruction Lighting Solutions
• Integrated controller• Full 5 year performance warranty• Universal 208 - 277V AC input• Controller can be mounted at the base of the
structure• NEMA 4x outdoor rated enclosures• Wide temperature range: -40oC to +55oC• Low power consumption• IP66 rated light fixtures• Impact and vibration resistant• Provision for padlock on the enclosure
• Effective intensity / power consumption• White Day = 270,000cd (220W)• White Twilight = 20,000cd (40W)• White Night = 2,000cd (30W)• Red Night = 2,000cd (30W)
• Dry contacts for alarm monitoring/status• Photocell alarm• Communication alarm• Sync alarm• Operation mode (day/night)• White mode alarm • Red mode alarm• Power fail alarm
• Controller integrated into flashhead• Integrated Photocell• Integrated Flasher• Full 5 year performance warranty• Universal 120-240V AC input• Wide temperature range: -40oC to +55oC• Low power consumption• IP66 rated light fixtures• Impact and vibration resistant • Dry contacts for alarm monitoring/status
North American HQ 1501 Route 34 South Farmingdale, NJ 07727 Tel: 732-919-3119 gi Fax: 732-751-5778 'N
Houston office 16830 Barker Springs Rd
Ste 407
Houston, TX 77084
Copenhagen Ejby lndustrivej 91 B
2600 Glostrup Tel: +45 8877 4400
Fax: +45 3582 0099 E-mail: [email protected]
EMEA HQ Exning Road, Newmarket
Suffolk, England, CB8 OAX
Tel: +44 (0) 1638 665161
Australia office
38 O'Malley St
Osborne Park WA 6017
Tel: +61 (0) 8 9244 7600
Brazil
Av. Joao Antonio Meccatti,
1601 - Galpao 07 - Jd Planalto Jundiai - SP - 1 321 1-223
Tel: +55 (11) 4431-4300
Fax: +55 (11) 4431-4300
Email:[email protected]
Middle East office Level 42
Emirates Towers (Office Tower)
Sheikh Zayed Road
Dubai, United Arab Emirates
Tel: +971(0)4319 7686
Southeast Asia office 240 Macpherson Road
#07-05 Pines Industrial Building
Singapore 348574
MDTFSHCATX001_T_041 21 6 MDTFSHCATX001_T_041216
North American HQ1501 Route 34 SouthFarmingdale, NJ 07727Tel: 732-919-3119 Fax: [email protected]
Houston office16830 Barker Springs Rd Ste 407 Houston, TX 77084
CopenhagenEjby Industrivej 91 B2600 GlostrupTel: +45 8877 4400Fax: +45 3582 0099E-mail:[email protected] EMEA HQExning Road, Newmarket Suffolk, England, CB8 0AX Tel: +44 (0) 1638 665161
Australia office 38 O’Malley StOsborne Park WA 6017 Tel: +61 (0) 8 9244 7600
BrazilAv. Joao Antonio Meccatti,1601 – Galpao 07 – Jd PlanaltoJundiai – SP – 13211-223Tel: +55 (11) 4431-4300Fax: +55 (11) 4431-4300Email:[email protected]
Middle East officeLevel 42 Emirates Towers (Office Tower) Sheikh Zayed Road Dubai, United Arab EmiratesTel: +971(0)4319 7686
Southeast Asia office240 Macpherson Road #07-05 Pines Industrial Building Singapore 348574