DIAMANTINSTALLATION MANUAL
www.gerardroofs.eu
![Page 2: DIAMANT - GERARD · 1. 2. 3. 4. Bottom tile Top tile 2 . 1. 1. 6. 7. 8. 9. 10. 4. 5. 2 . 3. Centerline of pan Edge of tile B Edge of tile A Bottom tile Tile A Tile B TILE LAYING](https://reader033.vdocuments.net/reader033/viewer/2022041901/5e6079a74167f104612ea702/html5/thumbnails/2.jpg)
UNDERLAY AND BATTENS
TECHNICAL
Length of cover: 1270 mm Width of cover: 398 mm Tiles/m2: 1.98Weight/m2: 6.28 kg Minimum Pitch: 14°
STORAGE AND HANDLING:If storage outside, a waterproof cover must be placed over the tiles to keep them dry and prevent damage to the substrate.
NON-STANDARD ELEMENTS: Materials that could cause corrosion (e.g. copper, lead, stainless steel) should not be used above the level of the roof.
ROOF TRAFFIC:Weight should be placed directly over the batten in pans of tile when walking on the roof.
WET SURFACE:Walking and working on a wet roof should not be attempted.
BATTENS:Recommended counter batten dimension is 50 x 80 mm. Tile batten size is 40 x 50 mm (distance between rafters less then 900 mm)
BATTEN SPACING:Batten spacing for Diamant is 398 mm.
LOCAL STANDARDS:It is strongly recommended that local building standards and regulations are always followed and fully complied with.
Overall installation manual:For more information see the GERARD INSTALLATION MANUAL
![Page 3: DIAMANT - GERARD · 1. 2. 3. 4. Bottom tile Top tile 2 . 1. 1. 6. 7. 8. 9. 10. 4. 5. 2 . 3. Centerline of pan Edge of tile B Edge of tile A Bottom tile Tile A Tile B TILE LAYING](https://reader033.vdocuments.net/reader033/viewer/2022041901/5e6079a74167f104612ea702/html5/thumbnails/3.jpg)
398 mm
RIDGE BATTEN
EAVESHIP BATTEN
GABLE
VALLEY BATTEN SPACING
398 mm
![Page 4: DIAMANT - GERARD · 1. 2. 3. 4. Bottom tile Top tile 2 . 1. 1. 6. 7. 8. 9. 10. 4. 5. 2 . 3. Centerline of pan Edge of tile B Edge of tile A Bottom tile Tile A Tile B TILE LAYING](https://reader033.vdocuments.net/reader033/viewer/2022041901/5e6079a74167f104612ea702/html5/thumbnails/4.jpg)
1.
2.
3.4.
360 mm 60 mm
180 mm
Bottom tile
Top tile
2 .
1. 1.
6.
7.
8.
9.
10.
4.5.
2 .
3.
Centerline of pan
Edge of tile BEdge of tile A
Bottom tile
Tile A
Tile B
TILE LAYING
INTERLOCKING OF THE TILES
NAIL POSITIONING
![Page 5: DIAMANT - GERARD · 1. 2. 3. 4. Bottom tile Top tile 2 . 1. 1. 6. 7. 8. 9. 10. 4. 5. 2 . 3. Centerline of pan Edge of tile B Edge of tile A Bottom tile Tile A Tile B TILE LAYING](https://reader033.vdocuments.net/reader033/viewer/2022041901/5e6079a74167f104612ea702/html5/thumbnails/5.jpg)
EAVES FLASHING
RIDGE INSTALLATION
HIP INSTALLATION
![Page 6: DIAMANT - GERARD · 1. 2. 3. 4. Bottom tile Top tile 2 . 1. 1. 6. 7. 8. 9. 10. 4. 5. 2 . 3. Centerline of pan Edge of tile B Edge of tile A Bottom tile Tile A Tile B TILE LAYING](https://reader033.vdocuments.net/reader033/viewer/2022041901/5e6079a74167f104612ea702/html5/thumbnails/6.jpg)
BOX BARGE INSTALLATION
VALLEY INSTALLATION
WALL FLASHING