dimensionamiento de loop us army
DESCRIPTION
Dimensionamiento de Loops de Tubería.TRANSCRIPT
DIMENSIONAMIENTO DE LOOPS US ARMY
Metric Units
English Units
Metric Units
English Units
Donde:
L = Loop length, mm (ft)
X = Parallel leg of loop, mm (ft)
Y = 2X = Tangential leg of loop, mm (ft)
D = Actual outside pipe diameter, mm (ft)
E = Modulus of elasticity at the working temperature, kPa (psi)
Sa =
Δ = Change in length due to temperature change, mm (in.)
C1= Constant, 0.3333
Datos:
D = 3.5 [in] Diametro exterior de la tuberia
l = 787 [in] Distancia entre frenos
α = 6.25E-06 Coeficiente de expansion termica @ Temp Ope
Top = 150 Temperatura de Operacion
Tamb = 59 Temperatura Ambiente
Ecuacion para calcular la expansion termica:
Δ = l x α x ΔT
Δ = 0.45 [in]
L = 7.79 [ft]
L = X + 2Y ec.1
Y = 2X ec. 2 `
L = 5X ec. 2 en ec. 1
X = 1.56 [ft] ≈ 18.70 [in]
Y = 3.12 [ft] ≈ 37.40 [in]
L = X + 2Y = (ΔDE/C1*Sa)0.5
L = X + 2Y = (3ΔDE/144 in² / ft²)Sa)0.5
L = 74.7 (ΔD)0.5
L = 6.225(ΔD)0.5
Maximum allowable stress at the workingtemperature, kPa (psi)
[in/in oF]
[oF]
[oF]
L = 6.225 (Δ*D)0.5