dinstar config elastix
TRANSCRIPT
-
8/10/2019 Dinstar Config Elastix
1/12
DINSTAR DAG1000-8O with Elastix
Setup Guide
Shenzhen Dinstar Technologies Co., Ltd.
Address: Floor 6, Guoxing Building, Changxing Road, Nanshan District, Shenzhen, China
518057
Telephone: +86 755 2645 6664
Fax: +86 755 2645 6659
Emails: [email protected], [email protected]
Website: www.dinstar.com
-
8/10/2019 Dinstar Config Elastix
2/12
A. Elastix Setup Procedure
To set up the Elastix Server for the DINSTAR DWG2001
A1Go to the web address of the Elastix Server Login page. The web address is determined by
the customer, for this guide we have used the IP address 172.16.33.58
Type the username and password for an administrative user into the Username and Password
fields
A2Press Enter or click on the Submit button to go to Elastixs Dashboard
-
8/10/2019 Dinstar Config Elastix
3/12
A3Once inside, click on the PBX tab on the menu at the top of the screen
A4Click Trunks and Add SIP Trunk menu to create a SIP trunk to DWG. This will take you to
the Add SIP Trunk page.
A5On the Add SIP Trunk page, fill in the following information:
Trunk name (gsmin this example)
Maximum Channels (8 in this example)
-
8/10/2019 Dinstar Config Elastix
4/12
Outgoing settings
Trunk Name (fxo in this example)
Host (172.16.66.7 in this example)
Incoming Settings
Username (10000 in this example)
Secret (aos123 in this example)
-
8/10/2019 Dinstar Config Elastix
5/12
A6Configure outbound route On the Add Outbound Routes page, fill in the following
information:
Route name (fxo in this example)
Set dial rule with prefix 9 in this example
-
8/10/2019 Dinstar Config Elastix
6/12
Then click Submit Changes to save the outbound route
A7Configure inbound route On the Add Inbound Routes page, fill in the following information:
Description (gsm in this example)
DID Number (s in this example)
Configure destination number of inbound route
Destination to IVR / Extension ( extension 8003 in this example)
Then click Submit to save the changes
A8Apply configuration changes
-
8/10/2019 Dinstar Config Elastix
7/12
B. DAG1000-8O Setup Procedure
B1Go to the web address of the DAG1000 Login page. The web address is determined by the
customer, default IP of the gateway is 192.168.11.1, and for this guide we have used the
DAG1000 and IP address 172.16.66.7
Default username: admin, Password: admin
The main page of DAG1000 FXO VoIP Gateway
IP Address ( 172.16.66.7 in this example)
Firmware Version (2.11.08.01 in this example)
-
8/10/2019 Dinstar Config Elastix
8/12
Send email [email protected] to get latest firmware version.
Upgrade firmware on the Maintenance-> Firmware Upload page
Select the firmware file and click Upload button then keep waiting till it reboot automatically.
B2Configure SIP server IP on theSystem Configuration-> SIP Parameter page
SIP Server Address ( 172.16.33.58 in this example)
SIP Server Port ( 5060 in this example)
SIP Register Interval (300s in this example)
mailto:[email protected]:[email protected] -
8/10/2019 Dinstar Config Elastix
9/12
Click the Save button on the buttom of the page
B3Configure authentication information on the Call Routing-> Port Group
SIP User ID (10000 in this example as configuration of Trunks, Reference A5)
To VoIP Hotline (DID Number s in this example as configuration of Inbound Routes,
reference A7)
-
8/10/2019 Dinstar Config Elastix
10/12
Note: s can be replaced by extensions or other DID number as per configuration of SIP
server. To call to extension/DID number automatically, users must configure To VoIP Hotline as
well as Tel-IP Operation.
B4Configure outbound route on the Call & Routing ->IP_Tel Routingpage
Description (Out in this example)
-
8/10/2019 Dinstar Config Elastix
11/12
B5Configure inbound route on theCall & Routing->Tel-IP Routingpage
Call from(Port Group 0 in this example)
Description (In in this example)
B6 Enable CID on the Advanced-> FXS/FXO page
-
8/10/2019 Dinstar Config Elastix
12/12
Enable One stage dialing