Disconnect Switches for use with Variable Frequency Drives Hubbell's Disconnect Switch for Variable Frequency Drives (VFDs) prevents downtime from out of sequence equipment shutdowns. The HBLDS3VFD integrates a verified break before break auxiliary contact factory installed in the HBLDS3 30 Amp disconnect switch enclosure that interfaces directly with VFDs. The use of VFDs are being extended to a wide variety of motor driven equipment applications. VFDs control the frequency of the electrical power supplied to motors. When a motor disconnect is turned off in a low frequency state, disconnect contacts can potentially be damaged. This can cause potential risk of injury to workers and equipment malfunctions, resulting in costly down time and repairs. Through extensive testing, Hubbell has found the use of an early break auxiliary contact safely disconnects the power by signaling the VFD that the motor disconnect is being turned off. The VFD then executes a coast-to-stop preventing any damage to the disconnect switch and the VFD output device. Tested to be effective for use with VFDs Powers down the drive prior to opening the motor disconnect Prevents damage to the motor disconnect and the VFD think SAFETY... think HUBBELL SAFE Enable Input Variable Frequency Drive Main Switch Drive Control Voltage 24V DC Normally Open Early Break Auxiliary Contacts

Upload: lylien

Post on 01-Jul-2018

233 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Disconnect Switches for use with Variable Frequency Drives · Disconnect Switches for use with Variable Frequency Drives ... Disconnect Switches for use with ... or visit our online

Disconnect Switches for use with Variable Frequency Drives

Hubbell's Disconnect Switch for Variable Frequency Drives (VFDs) prevents downtime from out of sequence equipment shutdowns. The HBLDS3VFD integrates a verified break before break auxiliary contact factory installed in the HBLDS3 30 Amp disconnect switch enclosure that interfaces directly with VFDs.

The use of VFDs are being extended to a wide variety of motor driven equipment applications. VFDs control the frequency of the electrical power supplied to motors. When a motor disconnect is turned off in a low frequency state, disconnect contacts can potentially be damaged. This can cause potential risk of injury to workers and equipment malfunctions, resulting in costly down time and repairs.

Through extensive testing, Hubbell has found the use of an early break auxiliary contact safely disconnects the power by signaling the VFD that the motor disconnect is being turned off. The VFD then executes a coast-to-stop preventing any damage to the disconnect switch and the VFD output device.

• Tested to be effective for use with VFDs

• Powers down the drive prior to opening the motor disconnect

• Prevents damage to the motor disconnect and the VFD

think SAFETY...think HUBBELLSAFE

EnableInput

HBLDS3VFD

Variable Frequency Drive

Main Switch

Drive ControlVoltage 24V DC

Normally Open Early BreakAuxiliary Contacts

Page 2: Disconnect Switches for use with Variable Frequency Drives · Disconnect Switches for use with Variable Frequency Drives ... Disconnect Switches for use with ... or visit our online

Wiring Systems

®

www.hubbell-wiring.com

Hubbell Wiring Systems • Hubbell Incorporated (Delaware) • 40 Waterview Drive • Shelton, CT 06484 Phone (800) 288-6000 • FAX (800) 255-1031 Printed in U.S.A. Specifications subject to change without notice. ® is a registered trademarks of Hubbell Incorporated. WLFS002 2/11

Disconnect Switches for use with Variable Frequency Drives

HBLDS3VFD

HBLAC2

IP66SUITABILITY

Existing CIRCUIT-LOCK® products which can be retrofitted in the field by adding the HBLAC2 early break auxiliary contacts.

Circuit-Lock® Unfused Disconnect Switches

Circuit-Lock® Unfused Mechanical Interlocks

Auxiliary Contact

Can be used in all existing 20A, 30A 60A and 100A unfused disconnect switches.

Can be used in all existing 20A, 30A 60A and 100A unfused mechanical interlocks.For ordering information, please see our full line catalog or visit our online catalog at www.hubbell-wiring.com.

Description Catalog No.30A Disconnect switch60A Disconnect switch100A Disconnect switch

HBLDS3HBLDS6HBLDS10

Auxiliary contact break before break; 1 set of n/o contacts

HBLAC2

Description Catalog No.30A Disconnect switch with integrated break before break auxiliary contact

HBLDS3VFD