disocont tersus measurement, control and supervisory...
TRANSCRIPT
Modular design
Product line for Mechatronic scales; a combination of mechanical, electrical and software components
Local or remote installation
Reduced engineering planning and wiring costs
Commissioning and diagnostics are graphically supported
Optional wireless access for service
DISOCONT® Tersus Measurement, Control and Supervisory System
Application
DISOCONT Tersus is a modular system for controlling continuous weighing and feeding applications. The controller is used wherever bulk solids need to be measured, fed or batched with the use of: Loss-in-weight feeders
(measuring/feeding) Weighfeeders Mass flow meters Solids flow meters Belt scales Weighing hoppers
The DISOCONT Tersus is easily integrated into the automation structures of a plant using the built-in Ethernet interface or optional fieldbus modules.
BV-D5084GB
Equipment
The DISOCONT Tersus electronics consist of a main VCU and multiple optional expansion VCU’s. Because of its modular design approach, a cost-effective system configuration is achievable.
Central unit VCU for all measurement and control functions with interface to operator panels and expansion VCU’s
EasyServe-PC-program for commissioning and service
Fieldbus communication modules plug into the VCU for transfer of all relevant data to the user’s control system
Additional expansion VCU is for discrete I/O and provides expanded control of the scale system
Operator panel with graphical display and touchscreen for operation of the scale and/or parameter modifications Integrated web server for browser
server access to logs, HMI and service information
Local control station for manual operation of motors to assist with setup and maintenance
Compatible with DISOCONT Master Group Controller, see data sheet for further details
Optional access via LAN, WLAN and Bluetooth
The internal DISOCONT Tersus communication bus permits a flexible arrangement of the VCU’s, locally or in cabinets. All modules can be replaced with no need for recalibration and reconfiguration.
Technical features for all weighing and feeding systems System accuracy for scales better
than 0.05 % (DIN EN 61143-1); Resolution of the weight signal: 24 million parts Galvanically isolated inputs/outputs Non-volatile process data retention Factory presets for easy and
quick commissioning Interfaces are multilingual,
selectable and loadable Status, event, calibration, and
batch reports Batch control with adaptive
accuracy improvement algorithm Simulation mode for testing
and learning
FunctionsDISOCONT Tersus is designed to acquire the actual feed rate, ex. [lb/h, t/h, etc.] via: Belt load and belt speed for belt
scales and weighfeeder applications Changes in weight of material in
weigh hopper per unit of time for loss-in-weight feeders
Reactive force for solids flow meters
Direct mass flow measurement using the Coriolis force for mass flow meters
The load of the feeding screw with automatic calibration via a check hopper for screw feeders
The VCU precisely controls the actual feed rate to match the setpoint. Depending on the type of scale, DISOCONT Tersus routes a control signal to a:
Speed-controlled weighfeeder drive or the drive of the feed helix Controllable loss-in-weight feeder
discharge unit Controllable solid and mass flow
feeder prefeederIn a batch mode, the DISOCONT Tersus feeds a preset amount of material and then automatically stops feeding at the end of the batch. The system has learning features which use the batch results for automatic adaptive accuracy improvement.
Interfaces
VCU 20100
Operator Panel VHM 20100
EasyServe VPC 20150 HMI via Web-Browser
Fieldbus
Ethernet Service Access
Modbus/TCP (standard)EtherNet/IP (standard)DeviceNet VCB 28020Modbus VSS 28020Profibus VPB 28020Profinet VPN 28020
Type hardware FunctionsVCU 20100 Central control unit, minimum 1 x
per system. Optional expansion via up to 2 additional VCU
VAI 20100 Single channel analog input card
VAO 20100 Single channel analog output card 0(4) ... 20 mA
VAO 20103 Single channel analog output card 0 ... 10 V
VME 20102 Load cell interface card (2 cards per VCU max.)
VEG 20100 VCU for cabinet enclosureVHM 20100 Touchscreen for control panel
mounting (powered by VCU)VHM 20110 Portable enclosed touchscreen
with cableVPB 28020 Profibus InterfaceVSS 28020 Modbus Interface
VCB 28020 DeviceNet Interface
VPN 28020 Profinet Interface
VPC 20150 Service-Software EasyServe for PC
VMO 20101 Local motor operator station
DISOCONT Tersus Component – Overview
DISOCONT Tersus System Unit VCU 20100
Standard Inputs*)
• Load cell input ±6 V, Ri > 87 Ω• 2 NAMUR-Inputs 0.03 … 3000 Hz for speed or belt sensor, flap limit switches• 5 Isolated, digital inputs 24 V, 20 mA
Optional Inputs*)
• Additional load cell input • Up to 2 analog input channels 0(4) ... 20 mA / 0 ... 10 V **)
Standard Outputs*)
• 1 isolated analog output 0(4) mA ... 20 mA, max. 11 V• 7 independent relay outputs 230 V / 1 A • Open collector output for external totalizer 30 VDC / 50 mA
Optional Outputs *)
• Up to 2 analog outputs 0(4) ... 20 mA or 0 ... 10 V **)
Serial interfaces
• 4 Ethernet RJ45, Ethernet/IP, Modbus/TCP• Interface for operator panel local bus• Interface for expansion VCU• Connection EasyServe RS232• Optional: 1 x Fieldbus plug in module
Power supply 24 VDC ±20 %;110 V … 230 V -20 % +10 %50 Hz or 60 Hz; 35 W
Ambient temperature
-25 °C ... +50 °Coutside of the housing
Protection class IP20Approvals CE, UL, ATEX
Technical Data
*) Control functions are freely assigned using EasyServe.**) 2 cards per VCU max.
Type software for VCU 20100
Functions/Applications
VBW 20170 Belt ScalesVWF 20170 Weighfeeders; DMO, DEA, MultidosVLW 20172 Loss-in-Weight Feeder;
MECHATRON, ProFlex, PureFeed, SolidsFlow
VIF 20170 Solids flow meters and feeders; Multistream, DLM
VMC 20170 Mass flow meters; MULTICOR
VBC 20170 Multi ingredient batch feeding
VSF 20170 MULTI-FLEX; screw feederVIO 20170 Expansion VCU
Material Stainless steelDimensions (mm) 9.85” x 5.75” x 3.86”
(250 mm x 146 mm x 98 mm) For installing DIN rail or for wall mounting
Protection classes IP20 (IEC 60 529)
VCU Housing VEG 20100
Schenck Process746 E. Milwaukee StreetWhitewater, WI 53190262-473-2441 or Fax: 262-473-4384 E-mail: [email protected] site: www.schenckprocess.com B
V-D
5084
GB
A
ll in
form
atio
n is
giv
en w
ithou
t obl
igat
ion.
All
spec
ifica
tions
are
sub
ject
to c
hang
e. ©
by
Sch
enck
Pro
cess
, 201
6
VHM 20100 20110Display TFT color display
4.53” x 3.50” (115 mm x 89 mm)Input Touch for pen and glove operation Power supply 24 VDC
4 W24 VDC4 W
Ambient temperature 5°-122° F (-15°-50° C)Dimensions W x H 7.95” x 6.06” (202 mm x 154 mm)Depth 1.79” (45.5 mm) 1.97” (50 mm)Protection class front back
IP65, 4X indoorIP20
IP65
Interfaces Ethernet RJ45 for local busApprovals CE, UL, ATEX
DISOCONT Tersus operator panel VHM Optional Fieldbus – interfaces to plant control
Quantity Maximum of one in main VCUType Profibus DP-V2
Profinet IOEthernet Modbus-TCPEthernet/IPDeviceNetModbus RS232/RS422/RS485
Data All process variablesAll parameters and configurationVia web server: Logged process data
Dimensions of the DISOCONT Tersus Operator Panel versions
Enclosure for cabinet mounting VEG 20100
Handheld devices
VHM 20100 VHM 20101 VHM 20110 VHM 20121
For panel mounting
Common front dimensions